t2

ADDENDUM LOG

June, 2009 Full Update

June, 2011 Plumbing content updated to include Seismic Gas Shutoff Valve (t15)

September, 2011 Waterproof membrane requirement updated

December, 2012 Updated Gas Shutoff Valve language (t15)

March, 2014 Distribution of utilities through exit corridors is prohibited with exception (t16)

October, 2014 Added Solar Panel language (t8)

October, 2014 At grade level electrical conduit is not allowed to be installed in the slab (t6)

December, 2014 Wiring language updated (t6, #9)

January, 2015 Tenants need to install a disconnect in their space (t5)

January, 2015 Languageregardingthewaterproofingmembrandeonpage t14 revised. (t14)

March, 2015 UpdatedPlumbingcontenttolistspecificlocationformain water shut off valve to be at eye level. (t14)April, 2016 AddedWaterEfficiencylanguage(t14)

April, 2017 Removed language regarding Telephone Service (t5) Replaced with language regarding Communications Services (t5)

January, 2018 Updated current layout

ADDENDUM LOG FASHION FAIR

Page 3: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t3

TECHNICAL CRITERIA

Electrical Criteria t4-t7

GeneralDesign/ConstructionCoordination t4

PowerSource,CommunicationServices t5 Lighting,TemporaryPower,ReuseofExisting ElectricalSystems t6 Material/EquipmentSpecifications, t7 FireAlarmSystem-LifeSafety t8

Mechanical Criteria t9-t17

GeneralDesign/ConstructionCoordination, LoadCalculations t9-t10

ExhaustRequirements,KitchenExhaust Systems,RoofPenetrations t10-t11

HVACInformationGeneralRequirements

BuildingManagementSystem t12-t13 ConditionsforHVACSystems t13-t14 StructuralConsiderations t14

Location&InstallationofRoofTop Equipment,CriteriaforReuseofExisting HVACRoofTopUnits,GeneralNotes t15 OdorProducingTenants/ExhaustSystems t16 AdditionalRequirementsforRestaurants t17

PlumbingCriteria t18-t20

GeneralDesign/ConstructionCoordination WaterEfficiency t18-t20

GasService,SeismicGasShutoffValve,Ventilation t20

StructuralCriteria&ExitCorridors t21

PLEASE VISITWWW.MACERICH.COM

TOVIEWPLANSUBMITTAL&APPROVAL

PROCEDURESandCONTRACTORRULES&

REGULATIONS

TABLE OF CONTENTS FASHION FAIR

Page 4: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

ELECTRICAL CRITERIA

General Design/Construction Coordination

TheelectricalcriteriaisprovidedforthepurposeofdesigningtheTenant’selectricalsystem.ThiscriteriaisprovidedasaguidelineforTenant’sEngineer.ItistheTenant’sresponsibilitytoverifyexistingconditionsandcomplywithallapplicablecodesandstandards.1. Conduitandracewayhangers,clamps,lightfixtures,junctionboxes,supports,etc.

mustbefastenedtojoistsand/orbeams.Donotattachdirectlytotheslab,roofdeck,ductwork,pipingorconduitabove.

2. Tenant’s equipment in the mall electric room must be clearly identified withTenant’snameandspacenumber.

3. Provideaccesspanelsatalljunctionboxeslocationsandatsmokedetectorsabovetheceiling.

4. All outlet boxes, floor boxes, wire raceways, power/telephone poles, plug-inmolding,wiringdevices,hangersupportsandotheritemsrequiredforacompletedistributionmustbefurnishedandinstalledbyTenant.

5. Furnishandinstallpowertorooftopunits,waterheater,storefixtures,signage,musicsystemsandanyotherfixturesorequipmentprovidedbyTenant.Anyroofcuttingandpatchingbymall’srequiredrooferatTenant’sexpense.

6. Allwiringmustbecopperandinconduit.Lowvoltagewiringmustbeinconduit.7. Systemgroundistobebuildingsteel.Structureisdesignedwitha“UFER”grounding

system.

8. Transformers shall be installed below finished ceilings. Theymay not not beanchoredtoorsuspendedfromtheexistingMallstructure,exteriorordemisingwalls.

9. ConduitisexistingormaybeprovidedbytheLandlordfromapointofdistributiontotheTenant’sdemisedpremises.

10.Theelectricalcircuitbreaker(mainbreaker)fortheTenantwillbefurnishedandinstalledbytheLandlordattheTenant’sexpense.

11.TheTenantisresponsibleforallelectricalworkwithintheTenant’sspace.12.The Tenantprovideswiring through the conduit from the Landlord’s point of

distributiontotheTenant’sspace.13.TheelectricalservicesizerequestedbyTenantissubjecttoapprovalbyLandlord.14.TheTenantwillconfirmthesizeoftheexistingelectricalserviceandensurethat

itissatisfactoryfortheTenant’sconditionsbeforeworkcommences.15.If the Tenant’s electrical requirements exceed the standard size provided by

the Landlord, the Tenantwill submit total Load Calculations to confirm theirrequirement.

Complete Engineered drawings must be submitted to the Landlord’s TenantCoordinatorforreviewandapproval.Landlordwillreviewtheplansforconformancetobasicmallrequirements.TheLandlorddoesnotreviewforelectricaldesign,nordoes the Landlord accept responsibility for the Tenant’s adherence to governingcodes.

t4

E L E C T R I C A L C R I T E R I A

FASHION FAIR

Page 5: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t5

The documents to be submitted for Landlord approval must include the following:

1. Completeplansandspecificationsforallelectricalwork, includinglighting,powerandonelineriserDiagram.DocumentsmustbesignedandsealedbyaLicensedEngineerinthestatewheretheShoppingCenterislocated.

2. Floorplan,includingbranchcircuitingandallequipmentlocations.3. Reflectedceilingplan,includinglightfixturelayoutandlightingfixtureschedule.4. Systemonelinediagram.5. ElectricalloadsummaryandPanelboardschedules,showingtheconnectedloadon

eachcircuitandthetotalconnectedload.6. Drawingsmustincludepanelschedules,loadcalculationsandmeterinformation.7. Structural drawingsmust be submitted for all equipment thatwill be suspended

fromthesteelstructure.

Power Source

AllworkrequiredtoconnectTenanttothemainpowersourcemustbeperformedbyLandlord’sdesignatedelectrician,atTenant’sexpense.ExceptionstothisrequirementmaybegrantedbytheTenantCoordinator.

Tenantisresponsibleforfeederstothetenantspacewithasingledisconnectwithinthetenantspacepriortoanytransformersorpanels,installationofadrytypetransformer,panels and complete distribution throughout the tenant space. A General Electricdemandcheckmetermustbeinstalledinthemallelectricroom.TenantisresponsibletoarrangeforelectricalserviceandmeterwithutilitycompanyatTenant’sexpense.

LandlordwillprovidethemainpowersourceforTenant’sconnection.Powersourcewillbe277/480vor120/280v,3phase,4wireandwillbeavailableinthenearestmallelectricroom.TenantsareresponsibleforinstallationofthefusedbusductdisconnectswitchandmustpullthefeederwirestotheTenant’sdemisedpremises.Landlordwillprovideanemptyconduitwithpull-wirefromthemallelectricroomtotheTenantspace. If a larger conduit is required,Tenant is responsible for installationof samefromthepowersourcetothedemisedpremises.

Communications Services

Landlordhasinstalledahigh-speedfiberinfrastructureattheCenterforpurposesofprovidingvoiceanddataaccessthroughouttheCenter.AllaccessforTenant’svoiceanddataservicesmustbesourcedthroughLandlord’sdesignatedproviderwhichiscurrentlyGraniteTelecommunicationsorsuchalternativeproviderasdesignatedbyLandlord.ThevendorcontactforvoiceanddataservicescanbefoundintheTenantCriteriaPackageunderGeneralInformation.

For allwiring needs in commonelectrical rooms, a required vendormust beusedtomaintaintheintegrityoftheelectricalroom.ThevendorcontactforlowvoltagewiringneedscanbefoundintheTenantCriteriaPackageunderGeneralInformation.

C O N T I N U E D

E L E C T R I C A L C R I T E R I A

FASHION FAIR

Page 6: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t6

LightingProvide a lighting schedule for review in conjunction with a reflected ceiling plan.Lightingmustconformtothefollowingguidelines:

1. DisplaywindowlightingmustbecontrolledbyatimeclockandbeonduringthehourstheShoppingCenterisopen.Displaywindowlightingattheceilingmustbeglare-freeandatapprovedlevelsatthestorefrontglassline.

2. TheTenantisresponsibleforalllightingwithintheTenant’sspace.TheTenantwillnotinstallanylightingoutsidetheTenant’sspacewiththeexceptionofMallrequiredstandardlightingatbackdoors.Thesefixturesshallbephotocellcontrolled.

3. Decorativefixturesforstorefrontillumination,suchasluminousceilings,chandeliers,pendantorwallunitsorcleartypeglitterstripsarepermittedifapprovedbyLandlord.Nostrobe,spinnerorchasetypelightingshallbeused.

4. Fluorescent or incandescent light fixtures in Tenant’s public areas, other thandecorative fixtures, shall be recessed. Fluorescent fixtures shall have deep cellparaboliclouvers.Barelampfluorescentorincandescentfixturesmaybeusedonlyinconcealedareasand/orstockrooms.

5. Tenantshallprovideemergency lightingpercodeto illuminatestockand/orsalesareasandrearexitwayduringpoweroutage.Emergencylightingshallbebattery-operated, twin-head light pack(s) and/or fluorescent fixtures. In public areas,emergencylightsshallbeconcealed.

6. Recessedincandescentdownlightsmaybeused.7. Exit,emergencyandnight lightsmustbeprovidedthroughout,asdeterminedby

governingcodes.

8. Fluorescentlightinginthesalesareamustberecessedandmustusemetalparaboliclouver type lenseswith aminimumof 18 cell configuration for a standard 2 x 2fixture.Barelampfluorescentorfluorescentfixtureswithacrylicprismaticlensesmaybeusedonlyinconcealedareasorstockrooms.

9. Tracklightingmaybeusedifthetrackispaintedtomatchtheceilingcolor.

Temporary Power

1. TheLandlordmayprovidetemporaryelectricalservicetotheTenantatamonthlycharge.Thischargewillbepaidasadditionalmonthlyrentnolaterthanthedateofcommencement.

2. TemporarywiringneededtoworkinthespaceshouldbeconnectedtotheTenant’selectricalserviceandnotcommonareaoutlets.

Reuse of Existing Electrical Systems

1. TheTenantwillsubmitalettertotheLandlordfromtheTenant’selectricalengineerstatingthattheexistingelectricalsystemisnotbeingaltered.

2. TheTenant’selectricalengineerwillbe licensed in thestate inwhichthework isbeingpreformed.

Tenantisresponsiblefor lightingsystemcontrol, includingconnectiontotheBuildingManagementsystemandconnectiontotheFireAlarmsystem.Allemergencylighting,exitsigns,hornsandstrobesmustbeprovidedbyTenantasrequiredbycode.

C O N T I N U E D

E L E C T R I C A L C R I T E R I A

FASHION FAIR

Page 7: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t7

C O N T I N U E D

E L E C T R I C A L C R I T E R I A

Material/Equipment Specifications

1. Drawingsmust includecompletematerialspecifications, includingmanufacturer’snameandproductnumberandcompleteschedulesofallequipmentandfixturestobeinstalled.

2. AllmaterialandequipmentmustbenewandofacommercialgradeandmustbearUnderwriter’slabelswheresuchlabelingapplies.

3. Atgradelevelelectricalconduitmaybeinstalledatleast4”undertheslabandmustbeinSchedule40PVCconduit.Butneverallowedtobeinstalledintheslaborlessthan4”belowslab.

4. Floorboxesmustbewatertight.5. Pullboxesorjunctionboxesmustbeaminimumof12gaugegalvanizedsteelout-

lets.Boxesinwallsmustbegalvanizedpressedsteelorcasemetal.Caulkaroundboxestoeliminatenoisetransmission.

6. Allmainandbranchfeedersandcircuitrywiringmustbecopper.Allconductorstohave600voltinsulationtypeTHW,THWNorTHHN.

7. Convenience receptaclesmust be specification grade, 120 volt, 20 amps and begroundingtypeperNEC.

8. Manual or magnetic starters, switches, contactors, relays, time switches, safetydevices,dimmersandothercontrolsmustbecommercialtypewithheavydutyrat-ingsandmustbe installed in strict conformancewith themanufacturer’s recom-mendationandapplicablecodes.

9. Anyexposedlowvoltagewiringmustbeplenumgraded.

10.Allwiringofanytypemustbeinstalledinconduitormustbearmoredcable(BX).Armoredcablewillonlybeallowedforconcealedbranchcircuitwiringwithinthedemisedpremises.Exposedand/oropenwiringofanykindwillnotbeallowed.Flexibleconduitsmustbeusedforconnectionstovibratingequipment.

11.Groundtobuildingsteel.12.Installtransformersbelowfinishceilings.

FASHION FAIR

Page 8: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t8

F I R E L I N E S A F E T Y C R I T E R I A

Fire Alarm System - Life Safety1. TenantmustprovideacompletefirealarmdetectionsystemwithintheTenantspace

separateoftheLandlord’sbuilding-wideaddressablefirealarmsystem.2. If applicable, Tenant is required touse Landlord’sdesignatedcontractor for installa-

tionofthenecessarysmokedetectorsandconnectiontothemainfirealarmsystem.Systemmustcomplywiththerequirementsofthegoverningauthority.

3. Allemergency lighting,exit signs,hornsandstrobesmustbeprovidedbyTenantasrequiredbycode.

Fire Protection/Sprinkler System Information

1. AllsprinklermodificationworkwillbeperformedbytheLandlord’srequiredcontrac-torfortheTenantattheTenant’sexpense.

2. Equipment:A. Standardsprinklerheadsinareaswithoutceilingswillbequickresponseupright

bronzeheads.B. Standardsprinklerheadsinareaswithfinishedceilingswillbequickresponse

semi-recessedchromeheads.C. FlushmountedheadsarerequiredthroughouttheDCA.D. TheTenantshouldcontactthelocalorstatefiremarshalforspecificrequirements

relatingtoquantityandlocationoffireextinguishers.Atminimum,Tenantistoinstallatleastonewallhung,2A10BCdrytypeUL-listedfireextinguisher.

E. Keepallpipingasclosetowallsandashightoundersideofroofframingaspos-sible.

F. RequiredDuctDetector:AnyHVACunit2000CFMorlarger,isrequiredtohaveasmokeductdetectorintheairsupply&returnofeachunit.Theductdetec-tormusthaveremotetestandalarmindicatorstationpercitycode.

G. ContractormustalsosubmitplanstotheFirePreventionBureauforapproval.TheTenant/Tenant’sContractorisresponsibleforallcitytestingandinspectionfees.

H. Ifrequired,Tenantswillfurnishandinstalltheirowncompletefirealarmsystemthat is compatiblewith the Landlord’s system. Tenant is responsible for anydevicesandconnectioncostsasmayberequiredto interfacewiththeLand-lord’ssystemwithallworkperformedattheTenant’sexpenseforanyportionofthemonitoringsystem,whetherinsideoroutsidetheTenantpremises.

I. Contractor shall notify the Landlord in writing at least 24 hours in advanceofmakinganymodificationstothesprinklersystems.Contractormustnotifythefiredepartmentandanyalarmmonitoring company for verification thatthesystemisfullydrained.ThecontractormustnotifytheLandlordwhenthesystemisbackonline.

J. Inordertoclearalarms,contractorshallcontactsecurityorMallmaintenancesupervisoratleast60minutespriortoanydraindown.Contractorshallremainforone(1)hourafterthesystemhasbeenrefilledtocheckforleaksorotherproblems.

K. Nosystemwillbelefttodrainovernight.Allsystemshavetobechargedandoperationalwhenworkerleaveforthenight.

L. Keepallpipingasclosetowallsandashightoundersideofroofframingaspos-sible.

FASHION FAIR

Page 9: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t9

M E C H A N I C A L C R I T E R I A

MECHANICAL CRITERIA

General Design/Construction Coordination

ThemechanicalcriteriaisprovidedforthepurposeofdesigningtheTenant’sheating,ventilatingandairconditioningsystem.ThiscriteriaisprovidedforTenant’sEngineer.ItistheTenant’sresponsibilitytoverifyexistingconditionsandcomplywithallapplicablecodesandstandards.Complete Engineered drawingsmust be submitted to Landlord’s Tenant Coordinatorforreviewandapproval.Landlordwillreviewtheplansforconformancetobasicmallrequirements.TheLandlorddoesnotreviewformechanicaldesign,nordoestheLand-lordacceptresponsibilityfortheTenant’sadherencetogoverningcodes.Equipmentorotherobstaclesplacedinthevicinityofexistingsolarpanelsshallfollowtheguidelinesoutlinedbelow:• Noequipmentshallbeplacedwithin10feetofanysolarinverterorACjunctionbox• Toavoidinterferingwithsolarpanelproduction,objectsshallbeplacednocloser

thanthedistancedefinedas2timestheirheight.Forexample,ifa4footHVACunitisinstalled,itmustbelocatedatleast8feetawayfromasolarpanel.

• Innocases,regardlessoftheheightshallanobstaclebeplacedwithin3feetofsolarequipment.

• No conduits, pipes or other devices shall be added to existing conduit carryingdevices

• Nowires,pipesorotherdeviceswillberoutedacrossoroverexistingsolarequip-ment.

• Allmodificationswithin20’ofsolarequipmentshall requirereviewandapprovalfromMacerichpersonnel.

The documents to be submitted for Landlord approval must include the following:1. Completeplansandspecificationscoveringtheheating,ventilatingandaircondi-

tioningsystemwork.Showmake,typeandperformanceofallequipment.Docu-mentsmustbesignedandsealedbyaLicensedEngineerinthestatewheretheshoppingCenterislocated.

2. Calculations showing the heating and cooling required, including transmissionandventilationlossesinthespaceandheatandcoolingprovidedfortheventila-tionsupplyandexhaustrequiredforthespace.Calculationsshallbeasdescribedin“LoadCalculations”includedbelow.

3. Temperature control system data showingmake, control and energymanage-mentsystems.

4. Exhaustsystemlayout,includingCFMandequipmentspecifications.5. Structuraldetailsforsupportofallrooftopequipmentandequipmentsuspended

fromthesteelstructure.

Load CalculationsTheTenantmustperformall calculations inaccordancewithmethods set forth inthelatestAmericanSocietyofHeating,RefrigerationandAirConditioningEngineers’GuideandDataBookandinaccordancewithgoodengineeringpractice.Allcalcula-tionsmustbetabulatedinaconcise,orderlymanner.Heating load calculation: Allspacesmustbecalculatedtomaintaintheminimumspacetemperaturesinsalesandpublicspacesof68degreesFand50degreesFinnon-publicspaces.

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 10: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t10

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

Cooling load calculation: Allspacesmustbecalculatedtomaintaintheminimumspacetemperatureof73degreesFandamaximumrelativehumidityof55degreesFandshalltakeintoaccountallinteriorheatproducingitemssuchaspeople,equipment,roofandexteriorwalls.TheTenantisrequiredtosubmitcalculationsindicatingtheheatingandcoolingloadsforthespaceandcalculationsforexhaustandmakeupair.TenantsmustdesignforamaximumnoisecriteriaofNC40forallspacesexceptkitchensandothersimilarworkareas.

Exhaust Requirements

Tenantswhoseoperationproducesobjectionableodorssuchasrestaurants,petshops,hair salons, nail salons, and the like must maintain 10% negative air pressure withrespecttotheMallbyprovidingmakeupairequalto90%exhaustairvolume.Tenantmaybe required toprovide,atLandlord’sdiscretion,a separatemakeupoutsideairsupplysystemtobalanceTenant’sexhaustsystem.Spacesthatrequireexhaustmustbedesignedtoprovidenegativeairpressurerelativetoadjoiningconditionedspacestopreventodortransfer.Roofmountedexhaustfansmustbeductedtoceilinggrilleslocatedapproximatelyinthecenterandrearofthedemisedpremisesandspecificallyneartheareawheretheodorsaregenerated.ThesystemshallbedesignedtocausetheexhaustairtogravitatefromtheMallCommonAreatotheodorproducingareaandthenexhaustedout.• Landlordmayrequirenailshopstoinstallscrubbers.Thiswillbedeterminedona

casebycasebasis.• Airfiltrationsystemsandbathroomexhaustfansarenotacceptablesolutions.• Theexhaustfanmustbeinterlockedwiththelightswitchesforthestorecustomer

servicearea.

• ThecombinedHVACandexhaustsystemmustbeinoperationduringallhoursthattheTenantisopenforbusiness.

Kitchen Exhaust Systems

KitchenexhaustsystemsaresubjecttoLandlord’sreviewtoensuretheexhaustdoesnotcompromisetheventilationairofadjacentmallrooftopunits.Kitchenexhaustsystemsaresubjecttothefollowingcriteria:1. TheexhaustfanmustbeaSWSIcentrifugalfanwhichmustbefittedwithamini-

mum10’-0”stainlesssteelupblast.Guywiresmustbeattachedtotheroofinordertosecurethestack.Usethemallrooferforconnectionoftheguywires.

2. A “Grease Guard” grease containment system (or approved equal) must beinstalledtoprotecttheLandlord’sroof.Aquarterlymaintenanceprogrammustbein-placeforthegreasecontainmentunits.ProofofthemaintenancecontractmustbepresentedtoLandlordpriortothestoreopening.

Roof PenetrationsIfuseofrooftopunits,roof-typesupplementalsupply,condensingunitsorexhaustairunitsbytheTenantispermittedbytheLandlord,unitsmustbelocatedonthatpartoftheroofofthebuildingdirectlyabovethedemisedpremisesasdesignatedbyLandlord.Tenantmustprovideandinstallallnecessarypipingandotherneces-saryappurtenancesfortheoperationoftherooftopequipment.TotheextentanyofTenant’sequipmentistobelocatedontheroof,theTenantagreestoerectroofunitsinaccordancewiththerequirementsoftheLandlordandtheTenantfurtheragreestorepairanyandalldamagetotheroofandstructurecausedbyhoistinginstallationandthemaintenanceand/orservicingofsuchequipment,allofwhichmustbeatthesolecostandexpenseoftheTenant.

FASHION FAIR

Page 11: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t11

TheTenantmustfurnishandinstallallcurbs,supports,lintels,pipes,ducts,ventcaps,airinlets,exhausthoods,louvers,flashings,counterflashing,etc.asrequiredforanyequipmentrequiringopeningsthroughtheroofand/orexteriorwalls.Theuseofcurbadaptersisnotallowed.TheLandlordhastherighttoinspectthequalityoftheworkandapprovelocationsand,iffoundunsatisfactory,rejectsame.Allcutting,patchingandrestoringofroofingistobedonebytheLandlord’sroofingcontractorattheTenant’sexpense.Allrepairs,maintenanceanddamagetotheroofand/orbuildingduetoTenant’sinstallationmustbeattheTenant’scostandexpense.

CloseoutRequirements1. Tenantmust submit as-built drawings and certifiedairbalance reportsprior to

constructioncloseoutshowingtheexactlocationofallequipmentandductwork.2. Tenantisrequiredtoproperlyabandonoldandunusedrooftopequipment(HVAC

units,exhaustfans,etc.)byfullremoval,includingcurbwithanappropriatemetaldeckandroofmaterialpatch. All roofingworkmustbeperformedbytheMallapprovedRoofingContractor.

3. Paversmustbeplacedaroundtherooftopequipmentandfromthemainpathwaytotheequipmentinordertoprotecttherooffromtraffic.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 12: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t12

HVAC Information

General Requirements

1. AnynewHVACunitorreplacementofanexistingHVACunitorthemodificationofanystructureorsubstructuresupportingtheunit(s)shallbedesigned,engineeredand installedat Tenants’ sole cost andexpense. Tenant shall provide structuralengineeringcalculationsanddrawingsfromalicensedstructuralengineer(Regis-teredintheStateoftheCenterwheretheworkislocated)toLandlordforreviewandapprovepriortoinstallationofanyunit.Allequipmentistobeinstalledoverstructuralmembersthatcansupporttheweightoftheequipmentinareasdesig-natedbyLandlord.Allrecommendationsofdesignandverificationofcompletionshallhavethestructuralengineer’sembossedsealfromthestate.

2. TheTenant’scontractorshallcoordinatewiththeLandlord’sapprovedroofingcon-tractorallcuttinganddrillingnecessaryfortheproperinstallationofequipment.TheLandlord’sapprovedroofingcontractorshalldoall repairsdamagetoworkunderotherheadingcausedbytheworkundertheheading,atthedirectandsolecostofTenant.

3. Allmechanicalequipmentincludinghousing,coils,finsandtubesmustbecooledtowithstandcorrosion.Inlieuofcoatingthetubesandfins,Tenantmayusecoppertubesandfins.

4. VibrationisolatorsarerequiredtobeinstalledonallHVACequipment,whetherontherooforwithintheTenantsspace.

5. AllsystemsshallbeeitherrooftopmountedHVACunits,orsplitsystems,depend-inguponthelocationoftheTenant’spremises.VerifylocationperHVACPlaninthiscriteria.

6. AllHVACunitsshallbebottomfedforsupplyandreturnair.7. AllHVACunitsshallbeequippedwitha120-voltoutletfromtheTenant’selec-

tricalservicemountedtotheunitontherooftop.8. AllcondensatelinesfromHVACunitsshallbecopperandinstalledasfollows:

A. LinesshallberunatrightanglesanddrainintoTenant’sspace.B. Supportsforthecondensatelinesshallbe4”x4”x12”treatedblockingset

inmasticonamodifiedbitumenpad.C. Pipesupportsshallbespacednofurtherthan6’-0”apart.

9. Atareaswhereelectricalconduitsorotherroofpenetrationsareremoved,theroofdeckmustberepairedbytheLandlord’sroofingcontractor,toan“as-new”condition.

10.The improvements shall in no way diminish or interfere with the structuralintegrityofthebuilding,roofstructureorwithroofdrainage.

11.Workmenpriortotheirleavingthepremisesshouldremovealldebris,materi-als,unusedparts,etc.

12.Ladderswillnotbepermittedonthesideofthebuildingforroofaccess.Roofaccessmaybeobtainedby checking in at theManagementOffice, atwhichtimeSecuritywillescortworkerstotheaccesspoint.AllworkersarerequiredtocheckoutattheManagementOfficewhenfinished.

13.Allreturnair istobeductedfromthefinishedceilingbacktotheHVACunit.Ceilingreturnairplenumisnotacceptable.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 13: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t13

14.Firedamperassemblies,(includingsleevesandinstallationprocedures)mustbeULlistedandapprovedbythebuildinginspectorprecedinginstallation.Installductandceilingaccesstofiredampers.Smokedetectorsmayberequiredinallreturnairorexhaustductwork.Thedetectorswilloverrideandshutdowntheairhandlingequip-mentwhensmokeisdiscovered.

15.FiberglassductsarenotpermittedforHVACtrunklines.FlexductispermittedforrunoutswithintheTenantpremisesandislimitedtoamaximumdistanceof4’-0”.

16.Exposedductworkisnotallowedontheroof.17.Balancingoftheairconditioningsystemwillbeperformedbyanindependenttest

andbalancingagencyatthesolecostandexpenseoftheTenant.18.TenantmustprovideweldingblanketstoprotectLandlordsroofduringanywelding

ontherooflevel.TenantmayberequiredtouseaDeputyInspectortoinspectallweldsatthesolecostandexpenseoftheTenant.Allmaterials,welds,connections,etc.installedbyTenantfortheHVACsystemmustbecoatedtowithstandcorrosion.

19.No improvements will be installed during inclement weather. Tie-in of flashingmaterialstomoistordustysurfacesshouldnotbeattempted.Existingmaterials,aswellasallmetalorconcretesurfaces,shouldbecleanedpriortoapplicationofnewmaterials.

20.Allelectricalconduit,metalpipe,orplasticpipingshouldberestrainedtoappro-priatesizedwoodblockingsetintoroofingcement.Attachmenttoblockingshouldallowformovementduetothermalexpansionandcontraction.

21.Platforms,curbs,andsleepersaretobetiedintotheexistingroofmembranebytheLandlord’sapprovedroofingcontractor,atthesolecostoftheTenant,inamanneracceptabletotheroofingmanufacturerandtheLandlord.

22.Providenewprefabricatedleadormetalpipesleeveflashingtosealanynewpipepenetrationsthroughtheroof.Flashingflangesshouldbe installed inamanneracceptabletotheroofingmanufacturerandtheLandlord.

Conditions for HVAC Systems

1. TenantwillprovidetheLandlordwithengineeringcalculations,whichassuretheadequacyoftheHVACsystemtheTenantisproviding.Tenantsonlowerlevelsarerequiredto installasplitsystem.Heat, ifrequiredbyTenant,tobeprovidedbyElectricHeatofHeatPumps.

2. Designconditions-heatingoftheTenant’sdemisedpremises:A. Insidedesigndrybulbtemperatureof73degreesFB. OutsidebulbtemperatureperAshraeGuideforlocation.

3. Designconditions-coolingoftheTenant’sdemisedpremises:A. Totalaircirculatedwillbebasedoninternalsensibleheatloadatpeakrequire-

ments,butnotlessthancoderequirements.B. Tenant’sHVACsystemshallprovideoutsideairforventilationofaminimum

roleof.1CFMpersquarefootofleasearea,butnotlessthancoderequire-mentsshouldsamebegreater.Outsideairflowthroughtheairconditioningunitonly.

C. ExhaustsystemswillbebasedoncodeandTenant’suserequirements.Onlyexhaustsystemswillbepermitted.Allexhaustmustbedischargeddirectlytotheoutside.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 14: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t14

4. Splitsystemswillbeallowedinareaswherearooftoppackageisnotsuitable.5. Smokedetectorsmayberequiredinallreturnairorexhaustductwork.Thedetectors

willoverrideandshutdowntheairhandlingequipmentwhensmokeisdiscovered.6. TheTenantmustcontractwithanoutsideHVACcontractorforregularrepairand

maintenanceofthesystemandprovideproofofsuchcontracttotheLandlordpriortothestoreopening.

7. Balancingoftheairconditioningsystemwillbepreformedbyanindependenttestandbalance agency at the sole cost and expenseof the Tenant. The air balancereportistobeprovidedtotheCenterofficepriortothestoreopening.Themechan-ical contractor shall cooperatewith the selectedbalanceagency in the followingmanner:A. Providedsufficienttimebeforefinalcompletiondatesothattestingandbalanc-

ingcanbeaccomplished.B. Provideimmediatelaborandtoolstomakecorrectionswhenrequiredwithout

unduedelay.Installbalancingdampersasrequiredbytestandbalanceagency.C. The contractor shall put all heating, ventilating and air conditioning systems

andequipmentintofulloperationandshallcontinuetheoperationduringeachworkingdayoftestingandbalancing.

D. Testingandbalancingagencyshallbekeptinformedonanymajorchangesmadetosystemduringconstructionandshallbeprovidedwithacompletesetofas-builtdrawings.

Structural Considerations

1. TheTenantmustretainaStructuralEngineer,registeredinthestateinwhichtheworkisbeingperformed.

2. TheTenant’sstructuralengineermustexaminetheexistingstructureanddeter-minethelocationforrooftopequipmentplacement.

3. TheTenant’sengineerwillprovidetheLandlordwitharecommendationforthesupportofrooftopequipment.

4. Locaterooftopequipmentovermajorstructuralelements.5. Reinforcetheroofsystemtoadequatelysupporttheweightofanyequipment

added.

6. Nostructuralormiscellaneousbridging,blocking,etc.,mayberemoved.7. TheLandlordmustapproveanymodificationsrequiredbeforeworkbegins.8. Uponcompletion,theTenant’sstructuralengineershallsubmitaletterstating

that the roof top equipment has been installed in accordancewith the engi-neer’srecommendeddesign.

9. ExistingrooftopequipmentthatisnotbeingusedbytheTenantshallberemovedanddisposedofattheTenant’sexpense.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 15: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t15

Location & Installation of Roof Top Equipment

1. Locateallrooftopequipmentasfarfromsidewallsaspossible.Rooftopequipmentwillnotbevisiblefromtheparkinglotoradjacentstreets.A. DistancebetweenFreshAirIntakeandExhaustunitsshallbeaminimumof15’-

0”.B. ItisthesoleresponsibilitytodesignandlocatethedistancesuchthatTenant’s

exhaustcannotbedrawnintotheFreshAirIntakeofanyexistingrooftopequip-ment.

2. Factorycurbsarerequiredfortheinstallationofallrooftopequipment.Curbsmustbeaminimumofeightincheshigh.

3. Roofpenetrationsmaynotbelocatedsoclosetooneanotherthattheyinterferewithproperflashing,orbeinstalledinanyroofwaterwayorareaoftheroofwhichpondswater.Ifplacementofanycurborplatformcausesrestrictionofwaterflowand/orcreatesapoundingsituation,acricketwillbeconstructedattheupslopesideofthecurb.CricketscanbeformedfromPerliteroofinsulationtoprovideamini-mumslopeof1/4”perfoot.

4. Roofpenetrationforcontrolandelectricalwiringshallbemadethroughtheequip-mentcurborasquarepitch-panlocatedwithin24”ofthecurb.

5. Thedistancebetweenthenewimprovementsandparapetwalls,existingequipmentcurbs,oranyrooftopprojection,shouldbenolessthan24”toallowforproperflash-ingandsealingoftheroofmembrane.

6. TheTenant’snameandsuitenumberwillbestenciledontheHVACunitasdesig-natedbyMallManagementOffice.

Criteria for Reuse of Existing HVAC Roof Top Units

TheleasemayallowsomeTenant’storeuseanexistingHVACsystemlocatedintheirTenantspace.InsuchcasestheTenantwillproceedasfollows:1. The Tenantmust establish that the existingHVAC installation conforms to the

Landlord’scriteria.2. ShouldtheTenantchoosetoreuseanexistingHVACunitandtheLandlorddeter-

minesthatanewunitisrequiredforanyreason,atanytimeduringthetermofthelease,theTenantmustinstallanewunitconformingtotheLandlord’scriteria.

3. TheTenantwillsubmitplansforapprovalpriortothealterationoftheexistingHVACsystem.

GENERAL NOTES:A. TenantmaynotreuseanHVACunit5yearsoldorover.Iftheexistingunitis

inexcessof5yearsold,anewunitshallbeinstalledinaccordancewiththeLandlord’scriteria,atthesolecostoftheTenant.

B. WhenreusinganexistingHVACsystemtheTenantisinnowayrelievedoftheresponsibilitytoconformtotheLandlordscriteriagoverningtheHVAC.

C. TheTenantmaynotaltertheexistingHVACsysteminanywaywithoutfirstsubmittingplansforapproval.

D. Prior toopening, theTenantwill submit the followingdocumentation; (i)aletterfromtheHVACContractorassertingthattheHVACunitisoperatingin“like-new”condition,(ii)acopyofthemaintenanceagreementforunit(s)tothe Landlord, (iii) theTenant’sHVACmaintenance contractormustprovidephotographsoftheexistingunit(s).

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 16: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t16

Odor Producing Tenants/Exhaust Systems

1. ThefollowingspecialrequirementsapplytoodorproducingTenants(includingbutnotlimitedtohairstyleshops,pet-shops,restaurantsorfastfooduseshops,andanyotheratLandlordsdiscretion).A. Odorproducingarea-Tenantisrequiredtofurnishandinstallthenecessaryequip-

menttoremoveanyodors.ThisworkwillbeapprovedinwritingbytheLandlordandatthesoleexpenseoftheTenant.ExamplesofsuchTenant’sinclude;hairornailshops,petshops,andfoodpreparationshops.

B. UsemotordrivenandfactorycurbSupremeupblastroofventilatormodelinstalledat aminimum of 40” from roofmembrane to discharge. Use a gauge weldedexhaustduct.Providemakeupairasnotedbelow,butnotlessthan85%ofamountofexhaust.

C. TheTenant,asrequiredbyspecialconditionssuchasgrills,restaurantexhaustsys-tems,etc.,willprovidespecialmakeupair.AlongwiththeHVACunit,theTenantmayuseanevaporativecooler.

D. Smokedetectorsmaybe required inall returnairorexhaustductwork tooverridetheairhandlingequipmentandprovideshutdownwhensmokereachestheequipment.

E. AgreasecontainmentsystemisrequiredforFoodserviceinstallations.

A. TheTenantwillprovidetheLandlordwithacopyofthemaintenanceagreementforthegreasecontainmentsystem.

B. Absolutelynoexposedductworkshallbeallowedontheroofrunningonahori-zontalplane.

C. All exhaust ductwork must be installed in conformance with N.F.P.A bulletin96and theuniformmechanical code. Locationofexhaustductworkand roofexhaustfansmusthavetheapprovaloftheLandlord.

D. AlongwiththeHVACunit,theTenantmauseanevaporativecooler(EssickorLandlordapprovedequal).

E. Theevaporativecooler(orothermake-upairunit).Theunitshallbeusedforthemake-upaironly.

a. Tenant shall operateHVAC Systembetween5 and10%negativepressureandshallprovideairbalancereportpriortoopeningandonayearlybasisasrequestedbyMallManagement.

b. Allinstallationsshallcomplywithgoverningcodesandbeapprovedbythefiremarshal.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 17: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t17

Additional Requirements for Restaurants:

1. Sizesand locations forallductandpiping throughroofmustbeshownonplans.Showallrequiredfireproofing.

2. Allgarbageandrefuseareaswashdown“grey”watermustbecontainedandprop-erlydrainedoffintocityapprovedsystem(i.e.sewerorstorm).

3. IftheTenantengagesinthepreparationoffoodorbakedgoods,Tenantagrees,atTenant’sexpensetodothefollowing:A. Installdrychemicalextinguishingdevices(suchasansul)approvedbythefire

insuranceratingorganizationcarriers.B. Maintainallexhaustductsandfiltersinacleancondition.C. PlaceandstoreTenant’sgarbageandrefuseincontainerswhichshallbekept,

untilcollected,inaself-containedareawithinthedemisedpremisessetasideforthestorageofgarbageand/orstoringofinflammableorcombustiblemate-rials,Tenantagreesto installandmaintainappropriatechemicalextinguishingdevices.

D. In theeventgas isused in thedemisedpremises,Tenantagrees to install anappropriategascutoffvalve.

E. ShouldtheTenantfailtoinstallanysuchdevicesreferredtointhissectionand/ortosubscribetotheservicingthereof,Landlordshallhavetherighttoenterthedemisedpremisesandtomakeanynecessaryinstallationsandchargethecostofsuchinstallationsand/ortheservicingthereoftoTenantwhichTenantagreestopaytoLandlord,asadditionalrent,withinten(10)daysafterdemand.

Note: See HVAC System Plan on the following sheet for the type of HVAC system required in each section of the mall.

C O N T I N U E D

M E C H A N I C A L C R I T E R I A

FASHION FAIR

Page 18: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

PLUMBING CRITERIA

General Design/Construction Coordination

Thefollowingcriteria isprovidedforthepurposeofdesigningtheTenant’splumbingsystem.ThiscriteriaisprovidedforTenant’sEngineer.ItistheTenant’sresponsibilitytoverifyexistingconditionsandcomplywithallapplicablecodesandstandards.

Complete Engineered drawingsmust be submitted to Landlord’s Tenant Coordinatorforreviewandapproval.Landlordwillreviewtheplansforconformancetobasicmallrequirements.TheLandlorddoesnotreviewforplumbingdesign,nordoestheLandlordacceptresponsibilityfortheTenant’sadherencetogoverningcodes.

The documents to be submitted for Landlord approval must include the following:

• Complete plans and specifications covering the complete plumbing system.DocumentsmustbesignedandsealedbyaLicensedEngineer inthestatewheretheShoppingCenterislocated.

The Tenant shall provide a complete plumbing system for the Tenant space. TheLandlordhasprovidedconnectionsineachtenantspaceforsanitarywasteandpotablecoldwater.

Tenantisresponsibleforallplumbingincludingtoilets,sinks,urinals,drains,hotwaterheaters,watercoolersandconnectionsintoexistingwaterandsewerlines.

Water Efficiency

1. TheTenantisrequiredtoinstallwaterlessurinalsintenantrestroomswhenurinalsareused.

2. Low-Flowwaterclosetsusing1.6GPForlessgallonsperflushwillbeinstalledinalltenantspaces.

3. Operationsensorsandlow-flowheadsusing0.5GPMorlessinlavatories.

Tenantshallprovideamainwatershutoffvalvelocatedateyelevelinawallbehindalabelledaccessdoor.LocateinornearemployeerestroomasdesignatedbyLandlord.Alldomesticsupplylinesshallbecopper.Sanitaryandventlinestraversingtheceilingareatobecastironorcopper(noPVC).Tenantwillutilizeelectricwaterheatersfordomestichotwater.

EveryTenantmustinstallahandicappedrestroomfacilitywithaminimumofonewaterclosetandonelavatoryandinaccordancewithlocalcodeofficials.AnexceptiontothisrequirementisonlypermittedforFoodCourtTenantswhoarewithincloseproximitytothepublicrestroomsuponapprovaloftheLandlordandlocalcodeofficial.

If applicable, second level restroomsmust install a3”floordrain. Anti- cockroachscreens over floor drains in storage rooms, closets or any areas where drains donotgetmuchuse.Mopsinksandwater fountainsmustbe installedper localcoderequirements.

t18

P L U M B I N G C R I T E R I A

FASHION FAIR

Page 19: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t19

Tenantmust install cleanouts as requiredby codeand Landlord’s requirements andtheseshallterminateflushwiththefinishfloororwall. Nocleanoutsarepermittedabovetheceiling.Garbagedisposalsarenotallowed.Hairsalonsandpetshopsshallprovidehairandsolidsinterceptorsonallsinksandbasinswhichmay receive human or animal hair. After installation, these hair interceptorsshallbeproperlymaintainedsoastokeepthesanitarysystemfreefromanyadverseconditions.

Except with Landlord’s prior written permission for non-compliance, all pot sinks,scullerysinks,pre-washsinksandotherkitchenunitsmustbeconnectedtoagreasetrap.Dishwashersmaynotbeconnectedtogreasetrap.

Waterproofingmustbe installed inall “wetareas” suchaskitchens, restrooms,mopsinks,drinkingfountains,etc.Thewaterproofmembranemustextend4”verticallyonalldemisingwalls.ThismembranewillbewatertestedbytheGeneralContractorandinspectedandsignedoffbyMallPersonnel.Ifthemembranefailsthewatertest,itmustbereplaced.

Foodservice,hairsalonsandphotographicprocessingorotherTenantswithequipmentoroperationsthathavethepossibilityofbackflowwillberequiredtoinstallanapprovedbackflowpreventer.Thesemustbecertifiedandacceptabletothewaterdistrictandcheckedyearlyorasrequiredbythelocalauthorityhavingjurisdiction.TenantsmustsubmitcalculationstotheLandlordwhichshowthesizeselectionorbasisofcapacityofallequipmentandpiping.

All waste piping designed and installed for the discharge of material from kitchenequipment,exceptdishwashers,shalldischargethroughagreaseinterceptorprovidedandinstalledbytenantpriortoconnectiontomall’ssanitarysystem.Greaseinterceptorsshallbecontainedcompletelywithinthedemisedpremisesandabovethefloorslaborinotherlandlordapprovedlocation.

1. WaterserviceforTenantsisprovidedfromatleasta1”diameterline.EachTenantisresponsiblefororderingandpayingfortheirownwatermetertotheirspace.

2. Theplumbingsystemshallbeinstalledinaccordancewithgoverningbuildingcodesandshoppingrequirements.

3. Lowflowplumbingfixturesarerequiredforwaterconservation.4. Afloordrainisrequiredtobeinstalledinalltoiletrooms.5. Waterpipingshallbecopperwith sweat typefittings.Sanitarypipeshallbecast

iron.6. Useleadjackets,8”orhigher,forroofventsonly.7. Allwastepipingdesignedandinstalledforthedischargeofmaterialfromkitchen

equipment,exceptdishwashers,shalldischargethroughagreaseinterceptorpro-vided and installed by Tenant prior to connection to Landlord’s sanitary system.GreaseinterceptorsshallbecontainedcompletelywithinthedemisedpremisesandabovethefloorslaborinotherLandlordapprovedlocation.

8. Allphotographicfilmprocessingequipmentmusthaveanapprovedreducedpres-sureprincipalbackflowpreventionassemblyinstalledatthewaterserviceconnec-tion(insidestore,aftermeter).

C O N T I N U E D

P L U M B I N G C R I T E R I A

FASHION FAIR

Page 20: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

t20

Gas ServiceAllnewdevelopmentandnewlyTenantedrestaurantsneedtohaveseismicgasshut-offvalvesinstalledonLandlordsideofthemeter,ateachindividualspace.Seismicvalvesmustbe:1.UL-approved;2.FM-approved;or,3.ACSE25-compliant.Alldevicesmustbeinstalledconsistentwithmanufacturer’sinstructionsandfollowingjuris-dictionalcode.

Gasmaybeavailableat thecenter.Tenant,at itssolecostandexpenseand incompliancewithlocalcodemustprocuregasservicetoandwithinthedemisedpremisesandwillmakeallnecessaryarrangementswiththelocalGasCompanyforsuchservice.Tenantisresponsibleforinstallationofagasmeteratthegasmeterheader.

PressureregulatorsandpipingrequiredforconnectiontoTenant’sequipmentistheresponsi-bilityoftheTenant.CoordinatewithLandlordforregulatorventrouting.Gaspipingontheroofmustbeplacedonpillowblocksorsimilararrangement.

Seismic Gas Shutoff Valve

AllTenantswhouseorhaveagaslineinstalledfortheirpremises,orequipmentthatservestheirpremises,arerequiredtoinstallacodeandLandlord-compliantseismicgasshutoffvalveonthemaingaslineservingthespace.

VentilationTenantswillprovideverticalexhaustductsatalocationdesignatedbyLandlord.Allhoodexhaustmustbeconnectedtoverticalductinaccordancewithcode.Tenantsarerequiredtoprovidefortheupkeepandmaintenanceforsuchverticalexhaustductandrelateddevicesandmaterials.

Allsanitarysewerandplumbingventpipingshallcomplywithalllocalcodes.Ventsthroughtheroofshallbeaminimumof4”andextendaminimumof8”abovefinishroof.

C O N T I N U E D

P L U M B I N G C R I T E R I A

FASHION FAIR

Page 21: TECHNICAL CRITERIA · Fire Alarm System - Life Safety t8 Mechanical Criteria t9-t17 General Design/Construction Coordination, Load Calculations t9-t10 Exhaust Requirements, Kitchen

STRUCTURAL CRITERIA

Thefollowingcriteria isprovidedforthepurposeofdesigningtheTenant’sstructuraldrawings. Thiscriteria isprovidedasaguidelineforTenant’sEngineer. It istheTen-ant’s responsibility toverifyexistingconditionsandcomplywithall applicable codesandstandards.

CompleteEngineereddrawingsmustbesubmittedtotheLandlord’sTenantCoordinatorforreviewandapproval.Landlordwillreviewtheplansforconformancetobasicmallrequirements.TheLandlorddoesnotreviewfordesign,nordoestheLandlordacceptresponsibilityfortheTenant’sadherencetogoverningcodes.

The documents to be submitted for Landlord approval must include the following:

• Completeplansandspecificationsforallstructuralwork.DocumentsmustbesignedandsealedbyaLicensedEngineerinthestatewheretheShoppingCenterislocated.

General Requirements

1. TheTenant’sstorefrontmustbestructurallyself-supported.Tenantmaynotsup-portthestorefrontfromthebulkheadorfascia.StructuralsupportforTenantstorefrontsmustbefromtheroofjoistsforlateralbracing.

2. Fixturesandequipmentmaynotbeattachedtoorsupportedfromthefloororroofdeck.

3. Structuraldrawingsarerequiredforallitemsthatrequiresupportfromthesteelstructureorforallrooftopequipmentweighing300lbsormore.

4. Joistreinforcingisrequiredforrooftopequipmentaswellassteelsupportforallroofopenings.

5. UpperlevelTenant’smustreviewbasebuildingstructuraldrawingspriortoinstallingasecuritysafe,ovensoranyequipmentweighing300lbs.ormore.

EXIT CORRIDORS

Distributionofutilitiesthroughanewlyconstructedoranalteredexitpassagewayisprohibitedexceptforequipmentandductworkspecificallyservingtheexitpas-sageway,sprinklerpiping,standpipes,electricalracewayforfiredepartmentcom-municationandelectricalracewayservingtheexitpassageway.

t21