Energy EquipmentEnergy Equipment

Refrigeration & Air Refrigeration & Air ConditioningConditioning

Page 2: Refrigeration - edit.ppt

2

©© UNEP 2006 UNEP 2006

Training Agenda: Refrigeration & Training Agenda: Refrigeration & Air ConditioningAir Conditioning

Introduction

Type of refrigeration

Assessment of refrigeration and AC

Energy efficiency opportunities

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 3: Refrigeration - edit.ppt

3

©© UNEP 2006 UNEP 2006

IntroductionIntroduction

How does it work?

Elect rical E

qui pme nt/

Refri gera tion &

AC

High Temperature Reservoir

Low Temperature Reservoir

R Work Input

Heat Absorbed

Heat Rejected

Page 4: Refrigeration - edit.ppt

4

©© UNEP 2006 UNEP 2006

IntroductionIntroduction

Thermal energy moves from left to right through five loops of heat transfer:

How does it work?Elect rical E

qui pme nt/

Refri gera tion &

AC

(Bureau of Energy Efficiency, 2004)

1)

Indoor air loop

2)

Chilled water loop

3)

Refrigerant loop

4)

Condenser water loop

5)

Cooling water loop

Page 5: Refrigeration - edit.ppt

5

©© UNEP 2006 UNEP 2006

IntroductionIntroduction

AC options / combinations:

AC SystemsElect rical E

qui pme nt/

Refri gera tion &

AC

• Air Conditioning (for comfort / machine)

• Split air conditioners

• Fan coil units in a larger system

• Air handling units in a larger system

Page 6: Refrigeration - edit.ppt

6

©© UNEP 2006 UNEP 2006

IntroductionIntroduction

• Small capacity modular units of direct expansion type (50 Tons of Refrigeration)

• Centralized chilled water plants with chilled water as a secondary coolant (50 – 250 TR)

• Brine plants with brines as lower temperature, secondary coolant (>250 TR)

Refrigeration systems for industrial processes

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 7: Refrigeration - edit.ppt

7

©© UNEP 2006 UNEP 2006

IntroductionIntroduction

• Bank of units off-site with common• Chilled water pumps

• Condenser water pumps

• Cooling towers

• More levels of refrigeration/AC, e.g.• Comfort air conditioning (20-25 oC)

• Chilled water system (8 – 10 oC)

• Brine system (< 0 oC)

Refrigeration at large companiesElect rical E

qui pme nt/

Refri gera tion &

AC

Page 8: Refrigeration - edit.ppt

8

©© UNEP 2006 UNEP 2006

Training Agenda: Refrigeration & Training Agenda: Refrigeration & Air ConditioningAir Conditioning

Introduction

Type of refrigeration

Assessment of refrigeration and AC

Energy efficiency opportunities

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 9: Refrigeration - edit.ppt

9

©© UNEP 2006 UNEP 2006

Types of RefrigerationTypes of Refrigeration

• Vapour Compression Refrigeration (VCR): uses mechanical energy

• Vapour Absorption Refrigeration (VAR): uses thermal energy

Refrigeration systemsElect rical E

qui pme nt/

Refri gera tion &

AC

Page 10: Refrigeration - edit.ppt

10

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

• Highly compressed fluids tend to get colder when allowed to expand

• If pressure high enough

• Compressed air hotter than source of cooling

• Expanded gas cooler than desired cold temperature

Page 11: Refrigeration - edit.ppt

11

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Two advantages

• Lot of heat can be removed (lot of thermal energy to change liquid to vapour)

• Heat transfer rate remains high (temperature of working fluid much lower than what is being cooled)

Page 12: Refrigeration - edit.ppt

12

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

©© UNEP 2006 UNEP 2006

Refrigeration cycle

Condenser

Evaporator

High Pressure

Side

Low Pressure

Side

CompressorExpansion Device

1 2

3

4

Page 13: Refrigeration - edit.ppt

13

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

©© UNEP 2006 UNEP 2006

Refrigeration cycle

Low pressure liquid refrigerant in evaporator absorbs heat and changes to a gas

Condenser

Evaporator

High Pressure

Side

Low Pressure

Side

CompressorExpansion Device

1 2

3

4

Page 14: Refrigeration - edit.ppt

14

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

©© UNEP 2006 UNEP 2006

Refrigeration cycle

The superheated vapour enters the compressor where its pressure is raised

Condenser

Evaporator

High Pressure

Side

Low Pressure

Side

CompressorExpansion Device

1 2

3

4

Page 15: Refrigeration - edit.ppt

15

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

©© UNEP 2006 UNEP 2006

Refrigeration cycle

The high pressure superheated gas is cooled in several stages in the condenser

Condenser

Evaporator

High Pressure

Side

Low Pressure

Side

CompressorExpansion Device

1 2

3

4

Page 16: Refrigeration - edit.ppt

16

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

©© UNEP 2006 UNEP 2006

Refrigeration cycle

Liquid passes through expansion device, which reduces its pressure and controls the flow into the evaporator

Condenser

Evaporator

High Pressure

Side

Low Pressure

Side

CompressorExpansion Device

1 2

3

4

Page 17: Refrigeration - edit.ppt

17

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Type of refrigerant

• Refrigerant determined by the required cooling temperature

• Chlorinated fluorocarbons (CFCs) or freons: R-11, R-12, R-21, R-22 and R-502

Page 18: Refrigeration - edit.ppt

18

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Compression RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Choice of compressor, design of condenser, evaporator determined by

• Refrigerant

• Required cooling

• Load

• Ease of maintenance

• Physical space requirements

• Availability of utilities (water, power)

Page 19: Refrigeration - edit.ppt

19

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Absorption RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Condenser Generator

Evaporator

AbsorberCold Side

Hot Side

Page 20: Refrigeration - edit.ppt

20

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Absorption RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Evaporator

Page 21: Refrigeration - edit.ppt

21

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Absorption RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Absorber

Page 22: Refrigeration - edit.ppt

22

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Absorption RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

High pressure generator

Page 23: Refrigeration - edit.ppt

23

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Vapour Absorption RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Condenser

Page 24: Refrigeration - edit.ppt

Exemple : 2 machines YAZAKI 7.5 R.T de Banyuls/MerSéminaire TRNSYS 10 septembre 2001 - INSA Lyon

Page 25: Refrigeration - edit.ppt

* Le système de rafraîchissement solaire (1) : Schéma de principe

Solar collectors

Eva Abs

Con

Gén

Bufferstorage

Absorption machineWFC 10 YazakiHot

waterstorage

Gas burner

BuildingTECSOL

Séminaire TRNSYS 10 septembre 2001 - INSA Lyon

Page 26: Refrigeration - edit.ppt

Séminaire TRNSYS 10 septembre 2001 - INSA Lyon

Puissance froid pour Tcond=32°C

0

5

10

15

20

25

30

35

40

4 5 6 7 8 9 10 11 12 13 14 15

Tseg (en °C)

Pf (e

n kW

) 80°C

85°C

88°C

95°C

Page 27: Refrigeration - edit.ppt

Courbes de C.O.P du modèle TRNSYS (2)

C.O.P pour Tcond=32°C

0,3

0,4

0,5

0,6

0,7

0,8

4 5 6 7 8 9 10 11 12 13 14 15

Tseg (en °C)

C.O

.P

80°C

85°C

88°C

95°C

Séminaire TRNSYS 10 septembre 2001 - INSA Lyon

Page 28: Refrigeration - edit.ppt

20

22

24

26

28

30

1 31 61 91 121

151

181

211

241

271

301

331

361

391

421

451

481

511

541

571

Nombre d'heures

°C

Garage_réel Garage_modélisé

* Modélisation de l’enveloppe : Découpage en 5 zones sous PREBID

Températures réelleset modélisées de la zone Garage de TECSOL du 1er au 25 août 2000

Kn

TTE n

réelel

q 81.0)( 2mod

Séminaire TRNSYS 10 septembre 2001 - INSA Lyon

Page 29: Refrigeration - edit.ppt

29

©© UNEP 2006 UNEP 2006

Type of RefrigerationType of Refrigeration

Evaporative CoolingElect rical E

qui pme nt/

Refri gera tion &

AC

(Adapted from Munters, 2001)

Cold Air

Hot Air

Sprinkling Water

• Air in contact with water to cool it close to ‘wet bulb temperature’

• Advantage: efficient cooling at low cost

• Disadvantage: air is rich in moisture

Page 30: Refrigeration - edit.ppt

30

©© UNEP 2006 UNEP 2006

Training Agenda: Refrigeration & Training Agenda: Refrigeration & Air ConditioningAir Conditioning

Introduction

Type of refrigeration

Assessment of refrigeration and AC

Energy efficiency opportunities

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 31: Refrigeration - edit.ppt

31

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

• Cooling effect: Tons of Refrigeration

• TR is assessed as:

Assessment of RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

1 TR = 3024 kCal/hr heat rejected

TR = Q xCp x (Ti – To) / 3024Q = mass flow rate of coolant in kg/hr Cp = is coolant specific heat in kCal /kg deg C Ti = inlet, temperature of coolant to evaporator (chiller) in 0C To = outlet temperature of coolant from evaporator (chiller) in 0C

©© UNEP 2006 UNEP 2006

Page 32: Refrigeration - edit.ppt

32

©© UNEP 2006 UNEP 2006

Specific Power Consumption (kW/TR)

• Indicator of refrigeration system’s performance

• kW/TR of centralized chilled water system is sum of• Compressor kW/TR• Chilled water pump kW/TR• Condenser water pump kW/TR• Cooling tower fan kW/TR

Elect rical E

qui pme nt/

Refri gera tion &

AC

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Assessment of Refrigeration

Page 33: Refrigeration - edit.ppt

33

©© UNEP 2006 UNEP 2006

Coefficient of Performance (COPCarnot)• Standard measure of refrigeration efficiency

• Depends on evaporator temperature Te and condensing temperature Tc:

• COP in industry calculated for type of compressor:

Elect rical E

qui pme nt/

Refri gera tion &

AC

COPCarnot = Te / (Tc - Te)

Cooling effect (kW)COP =Power input to compressor (kW)

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Assessment of Refrigeration

Page 34: Refrigeration - edit.ppt

34

©© UNEP 2006 UNEP 2006

Elect rical E

qui pme nt/

Refri gera tion &

AC

COP increases with rising evaporator temperature

(Te)

COP increases with decreasing condensing

temperature (Tc)

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Assessment of Refrigeration

Page 35: Refrigeration - edit.ppt

35

©© UNEP 2006 UNEP 2006

Measure• Airflow Q (m3/s) at Fan Coil Units (FCU) or Air

Handling Units (AHU): anemometer

• Air density (kg/m3)

• Dry bulb and wet bulb temperature: psychrometer

• Enthalpy (kCal/kg) of inlet air (hin) and outlet air (Hout): psychrometric charts

Calculate TR

Elect rical E

qui pme nt/

Refri gera tion &

AC

3024

h h ρ Q TR outin

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Assessment of Air Conditioning

Page 36: Refrigeration - edit.ppt

36

©© UNEP 2006 UNEP 2006

Indicative TR load profile

• Small office cabins : 0.1 TR/m2

• Medium size office (10 – 30 people occupancy) with central A/C: 0.06 TR/m2

• Large multistoried office complexes with central A/C: 0.04 TR/m2

Assessment of Air ConditioningElect rical E

qui pme nt/

Refri gera tion &

AC

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Page 37: Refrigeration - edit.ppt

37

©© UNEP 2006 UNEP 2006

• Accuracy of measurements• Inlet/outlet temp of chilled and condenser

water

• Flow of chilled and condenser water

• Integrated Part Load Value (IPLV)• kW/TR for 100% load but most equipment

operate between 50-75% of full load

• IPLV calculates kW/TR with partial loads

• Four points in cycle: 100%, 75%, 50%, 25%

Considerations for AssessmentElect rical E

qui pme nt/

Refri gera tion &

AC

Assessment of Refrigeration and ACAssessment of Refrigeration and AC

Page 38: Refrigeration - edit.ppt

38

©© UNEP 2006 UNEP 2006

Training Agenda: Refrigeration & Training Agenda: Refrigeration & Air ConditioningAir Conditioning

Introduction

Type of refrigeration

Assessment of refrigeration and AC

Energy efficiency opportunities

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 39: Refrigeration - edit.ppt

39

©© UNEP 2006 UNEP 2006

1. Optimize process heat exchange2. Maintain heat exchanger surfaces3. Multi-staging systems4. Matching capacity to system load5. Capacity control of compressors6. Multi-level refrigeration for plant needs7. Chilled water storage8. System design features

Elect rical E

qui pme nt/

Refri gera tion &

AC

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

Page 40: Refrigeration - edit.ppt

40

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

High compressor safety margins: energy loss

1. Proper sizing heat transfer areas of heat exchangers and evaporators

•Heat transfer coefficient on refrigerant side: 1400 – 2800 Watt/m2K

•Heat transfer area refrigerant side: >0.5 m2/TR

2. Optimum driving force (difference Te and Tc): 1oC raise in Te = 3% power savings

1. Optimize Process Heat ExchangeElect rical E

qui pme nt/

Refri gera tion &

AC

Page 41: Refrigeration - edit.ppt

41

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

Elect rical E

qui pme nt/

Refri gera tion &

AC

Evaporator Temperature (0C)

Refrigeration Capacity*(tons)

Specific Power Consumption (kW/TR)

Increase kW/TR (%)

5.0 67.58 0.81 -0.0 56.07 0.94 16.0-5.0 45.98 1.08 33.0

-10.0 37.20 1.25 54.0-20.0 23.12 1.67 106.0

(National Productivity Council)Condenser temperature 40◦C

1. Optimize Process Heat Exchange

Condensing Temperature (0C)

Refrigeration Capacity (tons)

Specific Power Consumption (kW /TR)

Increase kW/TR (%)

26.7 31.5 1.17 -35.0 21.4 1.27 8.540.0 20.0 1.41 20.5

*Reciprocating compressor using R-22 refrigerant. Evaporator temperature.-10◦ C

Page 42: Refrigeration - edit.ppt

42

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

3. Selection of condensers

• Options: • Air cooled condensers• Air-cooled with water spray condensers• Shell & tube condensers with water-cooling

• Water-cooled shell & tube condenser• Lower discharge pressure• Higher TR• Lower power consumption

1. Optimize Process Heat ExchangeElect rical E

qui pme nt/

Refri gera tion &

AC

Page 43: Refrigeration - edit.ppt

43

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

• Poor maintenance = increased power consumption

• Maintain condensers and evaporators• Separation of lubricating oil and refrigerant• Timely defrosting of coils• Increased velocity of secondary coolant

• Maintain cooling towers• 0.55◦C reduction in returning water from cooling

tower = 3.0 % reduced power

2. Maintain Heat Exchanger SurfacesElect rical E

qui pme nt/

Refri gera tion &

AC

Page 44: Refrigeration - edit.ppt

44

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

Effect of poor maintenance on compressor power consumption

2. Maintain Heat Exchanger SurfacesElect rical E

qui pme nt/

Refri gera tion &

AC

(National Productivity Council)

Condition Te (0C)

Tc (0C)

Refrigeration Capacity* (TR)

Specific Power

Consumption (kW/TR)

Increase kW/TR

(%)

Normal 7.2 40.5 17.0 0.69 -Dirty condenser 7.2 46.1 15.6 0.84 20.4Dirty evaporator 1.7 40.5 13.8 0.82 18.3Dirty condenser and evaporator

1.7 46.1 12.7 0.96 38.7

Page 45: Refrigeration - edit.ppt

45

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

• Suited for

• Low temp applications with high compression

• Wide temperature range

• Two types for all compressor types

• Compound

• Cascade

3. Multi-Staging SystemsElect rical E

qui pme nt/

Refri gera tion &

AC

Page 46: Refrigeration - edit.ppt

46

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

a. Compound• Two low compression ratios = 1 high

• First stage compressor meets cooling load

• Second stage compressor meets load evaporator and flash gas

• Single refrigerant

b. Cascade• Preferred for -46 oC to -101oC

• Two systems with different refrigerants

3. Multi-Stage SystemsElect rical E

qui pme nt/

Refri gera tion &

AC

Page 47: Refrigeration - edit.ppt

47

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

• Most applications have varying loads

• Consequence of part-load operation • COP increases• but lower efficiency

• Match refrigeration capacity to load requires knowledge of• Compressor performance• Variations in ambient conditions• Cooling load

4. Matching Capacity to Load SystemElect rical E

qui pme nt/

Refri gera tion &

AC

Page 48: Refrigeration - edit.ppt

48

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

5. Capacity Control of CompressorsElect rical E

qui pme nt/

Refri gera tion &

AC

• Cylinder unloading, vanes, valves• Reciprocating compressors: step-by-step

through cylinder unloading:• Centrifugal compressors: continuous

modulation through vane control• Screw compressors: sliding valves

• Speed control• Reciprocating compressors: ensure

lubrication system is not affected• Centrifugal compressors: >50% of capacity

Page 49: Refrigeration - edit.ppt

49

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

5. Capacity Control of CompressorsElect rical E

qui pme nt/

Refri gera tion &

AC

• Temperature monitoring• Reciprocating compressors: return water (if

varying loads), water leaving chiller (constant loads)

• Centrifugal compressors: outgoing water temperature

• Screw compressors: outgoing water temperature

• Part load applications: screw compressors more efficient

Page 50: Refrigeration - edit.ppt

50

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

Bank of compressors at central plant• Monitor cooling and chiller load: 1 chiller full

load more efficient than 2 chillers at part-load

• Distribution system: individual chillers feed all branch lines; Isolation valves; Valves to isolate sections

• Load individual compressors to full capacity before operating second compressor

• Provide smaller capacity chiller to meet peak demands

6. Multi-Level RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Page 51: Refrigeration - edit.ppt

51

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

Packaged units (instead of central plant)• Diverse applications with wide temp range

and long distance

• Benefits: economical, flexible and reliable

• Disadvantage: central plants use less power

Flow control• Reduced flow

• Operation at normal flow with shut-off periods

6. Multi-Level RefrigerationElect rical E

qui pme nt/

Refri gera tion &

AC

Page 52: Refrigeration - edit.ppt

52

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

• Chilled water storage facility with insulation

• Suited only if temp variations are acceptable

• Economical because• Chillers operate during low peak demand

hours: reduced peak demand charges• Chillers operate at nighttime: reduced tariffs

and improved COP

7. Chilled Water StorageElect rical E

qui pme nt/

Refri gera tion &

AC

Page 53: Refrigeration - edit.ppt

53

©© UNEP 2006 UNEP 2006

Energy Efficiency OpportunitiesEnergy Efficiency Opportunities

• FRP impellers, film fills, PVC drift eliminators

• Softened water for condensers

• Economic insulation thickness

• Roof coatings and false ceilings

• Energy efficient heat recovery devices

• Variable air volume systems

• Sun film application for heat reflection

• Optimizing lighting loads

8. System Design FeaturesElect rical E

qui pme nt/

Refri gera tion &

AC

Page 54: Refrigeration - edit.ppt

54

Training Session on Energy Training Session on Energy EquipmentEquipment

Refrigeration & Air Refrigeration & Air Conditioning SystemsConditioning Systems

THANK YOUTHANK YOU

FOR YOUR ATTENTIONFOR YOUR ATTENTION

©© UNEP 2006 UNEP 2006

Elect rical E

qui pme nt/

Refri gera tion &

AC

Page 55: Refrigeration - edit.ppt

55

© UNEP 2006© UNEP 2006

Disclaimer and ReferencesDisclaimer and References

Elect rical E

qui pme nt/

Refri gera tion &

AC

• This PowerPoint training session was prepared as part of the project “Greenhouse Gas Emission Reduction from Industry in Asia and the Pacific” (GERIAP). While reasonable efforts have been made to ensure that the contents of this publication are factually correct and properly referenced, UNEP does not accept responsibility for the accuracy or completeness of the contents, and shall not be liable for any loss or damage that may be occasioned directly or indirectly through the use of, or reliance on, the contents of this publication. © UNEP, 2006.

• The GERIAP project was funded by the Swedish International Development Cooperation Agency (Sida)

• Full references are included in the textbook chapter that is available on www.energyefficiencyasia.org