piotr wolański warsaw university of technology, 00-665 warsaw, poland

Download Piotr Wolański Warsaw University of Technology, 00-665 Warsaw, Poland

If you can't read please download the document

Upload: alana-comerford

Post on 14-Dec-2015

223 views

Category:

Documents


3 download

TRANSCRIPT

  • Slide 1

Piotr Wolaski Warsaw University of Technology, 00-665 Warsaw, Poland Slide 2 Nearly 40 years ago in Chorzow Chemical Plant Azoty explosion of synthesis gas killed four workers. Explosion happened during failure of high pressure gas installation in which mixture of hydrogen and nitrogen (3H 2 N 2 ), used for synthesis of ammonia, was at high pressure (about 300 bar) and high temperature (about 300 0 C). Since during expansion gas is cool down and selfignition temperature was far above initial temperature, search for external ignition source was started. No such source was found, so we were asked to explain the reason. This was motivation to initiate research to found real reason for ignition. Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Slide 15 Slide 16 Slide 17 Slide 18 Hydrogen fueled car and refueling station at Tocho Gas in Japan. Slide 19 Slide 20 L [mm]D [mm] 102532 45xxx 65x 75x 95xx Lengths and diameters of the tube tested in the research Slide 21 Pressures and signal from photodiode courses. Extension tube length 45 mm, extension tube diameter 25 mm, initial hydrogen pressure equal to 7.6 MPa Slide 22 Direct pictures of the hydrogen outflow, extension tube length 45 mm, extension tube diameter 32 mm, initial hydrogen pressure equal to 6.2 MPa. Frame rate 80 000 f/s, shutter 1/182 000 s. Slide 23 Direct pictures of the hydrogen outflow, extension tube length 65 mm, extension tube diameter 10 mm, initial hydrogen pressure equal to 7.4 MPa. Frame rate 80 000 f/s, shutter 1/182 000 s. Slide 24 Results of the experiments as a function of pressure and length of the tube. Tube diameter equal to 10 mm. Slide 25 Critical value of the hydrogen pressure required for ignition as a function of length of the tube. Tube diameter equal to 10 mm. Slide 26 Results of the experiments as a function of pressure and diameter of the tube. Tube length equal to 95 mm. Slide 27 Number of tests as a function of pressure range and length of the extension tube Slide 28 Reconstruction of the experimental facility. Initial conditions 1. High pressure hydrogen - red region on the left hand side of the membrane. Slide 29 Reconstruction of the experimental facility. Initial conditions 2. High pressure hydrogen - red region on the left hand side of the membrane. Slide 30 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 31 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 32 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 33 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 34 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 35 Comparison of experimental and numerical results. 2 nd order upwind, explicit. Left - 2 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 36 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 37 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 38 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 39 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 40 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 41 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 42 Comparison of experimental and numerical results. 2 nd order upwind, implicit. Left 1 initial conditions, temperatura distribution (80 bar initial pressure). Right direct pictures from experiment (76 bar H2 initial pressure) 50 mm Slide 43 It was first time shown nearly 40ty years ago that outflow of the high pressure combustible gas can be a source of ignition. Ignition can be obtained both in incident as well as in reflected shock wave. In case of reflected shock wave, which might be more often case in reality, parameters of outflowing gas which can initiate explosion are even lower. In case of reflected wave, geometry (such as cavities) which might focus reflected shock, might additionally lower ignition parameters. Slide 44 Also spilled fuel on surface can be potential source of ignition. In this case even outflow of air or even inert gas can initiate combustion and possible explosion. So, research on this direction must be continued to evaluate more accurately conditions which will lead to ignition during outflow of gas from the high pressure installation. Slide 45 Hydrogen ignition takes place behind the contact surface of the wave generated by hydrogen outflowing from high pressure installation, due to mixing of air heated by created shock wave with expanding hydrogen. Geometry of the extension tube significantly influences ignition process during outflow of the high pressure hydrogen. Slide 46 Ignition process shows stochastic behavior, since it depends very much on random processes associated with opening of the diaphragm (membrane). The results of the experimental tests and numerical simulations show that geometry of the extension tube and the process of the diaphragm opening have a significant influence on the presence of the hydrogen ignition and the flame propagation. Slide 47 More research is necessary to explain complicated nature of this phenomenon. Slide 48 THANK YOU FOR YOUR ATTENSION!