Page 1: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Bob Critoph, University of Warwick

Warwick Gas Heat Pump and Thermal

Transformer Update, October 2017

Page 2: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

• Box-for-box exchange for

conventional gas boiler

Retrofit market (> 90% of

annual sales)

• Air source

• 7kW (3 bedroom semi-

detached house)

30 - 40% reduction in

gas consumption

The vision:

Page 3: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

0

10

20

30

40

50

60

2025 2030 2035 2040 2045 2050

CO

2 E

missions

(Mt per annum

)

Year

Status Quo

70% Market Share

100% Market Share

Market Scenarios:

Two scenarios are considered:

▶The first assumes that the market for Gas Heat Pumps will saturate at a 70% share of gas heating appliances annual sales after approximately 12 years (the rest of the market remaining as condensing boilers).

▶The second assumes that after 7 years on the market, the cost of Gas Heat Pumps reaches the point wherelegislation requiring their use is introduced, in much the same way as was carried out for condensing boilers replacing non condensing boilers.

▶A 2.6% reduction in UK annual CO2

emissions by 2040 is possible.

▶There is a potential for an eventual 4.2% reduction in annual CO2 emissions if all gas boilers were replaced by gas heat pumps

Study of potential impact on emissions in the UK

Mean GUE = 1.37

Page 4: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

R&D at Warwick:

1: Carbon –ammonia

adsorption

Page 5: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Experimental Results (June 2016)

Experiment Model

Cycle

Time

[s]

Load

Inlet

[°C]

Load

Outlet

[°C]

Evaporating

Temperature

[°C]

COP COP

480 26.2 31.7 3.2 1.34 1.33

420 27.1 33.1 0.1 1.32 1.31

420 28.2 34 3.7 1.33 1.3

480 28.8 35.1 -1.6 1.3 1.3

420 32.9 37.9 3.9 1.255 1.29

360 33.4 38.8 4 1.23 1.27

540 37.6 42.7 1.9 1.244 1.25

480 38 43.4 1.8 1.233 1.25

300 40.5 46.7 3.5 1.19 1.21

Heating Power: 7.5 – 9 kWCOP: 1.19 – 1.34

Conclusion:

Machine performed as predicted,however, high manufacturing cost of the generators prohibited further development.

Page 6: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

6

New Generator Design

Shell and Finned Tube

Design Parameters:

• Tube diameter

• Tube pitch

• Carbon thickness

• Fin thickness

• Turbulator tube insert

Detailed simulations in Matlab

Page 7: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Large Temperature Jump Test

100 mm Long Test Sample

Page 8: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Match obtained between experiment and model predicted pressure rise

Time constant

~50 seconds

Large Temperature Jump Test

Page 9: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

9

Machine Construction

Page 10: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

1

Performance Predictions

Page 11: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

0

2

4

6

8

10

12

14

16

18

20

0 100 200 300 400 500 600 700 800

Pre

ssu

re [b

ar]

Time [s]

Pressure

P Bed A P Bed B P Cond P Evap

Page 12: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

0

20

40

60

80

100

120

140

160

180

0 100 200 300 400 500 600 700 800

Tem

per

atu

re [

C]

Time [s]

Bed Water Temperatures

Bed A In Bed A Out Bed B In Bed B Out

Page 13: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Test results analysis

• Heat transfer as predicted

• Desorption as predicted

• Adsorption slower than predicted

• Mass transfer being improved by material tweak

• On course to publish full performance map by end of year.

Page 14: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

BEIS Low Carbon Technolgy Heating

Innovation Fund

• Funding awarded provisionally to develop to a product

• 2½ years from July??

• Working with Dynamiq Engineering

Page 15: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

R&D at Warwick: 2: Salt –ammonia adsorption – joint

project with ECN

Page 16: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Desorption

at low

pressure

Heat out at

150°C

Adsorption

at high

pressure

Phase 1: Storage of heat at

90°C

Phase 2: Discharge of heat at

150°C

1-Salt Thermal Transformer (TT)

Salt 1 Condenser

Salt 1 Evaporator

16

Page 17: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Heat out at

150°C

Low

pressure

Phase 2: LT salt desorbs,

HT salt adsorbs

Phase 1: HT salt desorbs,

LT salt adsorbs

• 2 salts have lower pressures

compared to 1 salt with

condenser/evaporator

• less susceptible to sensible

heat thermal mass losses

2-Salt Thermal Transformer (TT)

(CaCl2 & MgCl2?)

High

pressure

LT SaltHT Salt

17

LT SaltHT Salt

Page 18: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Low

pressure

Phase 2: LT salt desorbs,

HT salt adsorbs

Phase 1: LT salt adsorbs,

HT salt desorbs

2-Salt heat pump

We can also have heat

pumps, refrigerators, etc.

18

High

pressure

LT SaltHT Salt

LT SaltHT Salt

Page 19: Warwick Gas Heat Pump and Thermal Transformer Update ... files/Progress AB May 2018/RC - AB meeting - 22nd... · conventional gas boiler Retrofit market (> 90% of annual sales) •Air

Thank you for your attention

• Any questions?