foampro 1600 1601 systems_1

11
Class A Foam Edition 1 May 2009 FoamPro 1600/1601 Direct Injection FoamPro 1600/1601 Direct Injection Proportioning Systems Proportioning Systems

Upload: simon-bertoli

Post on 30-Nov-2015

93 views

Category:

Documents


1 download

TRANSCRIPT

Class A Foam

Edition 1 May 2009

FoamPro 1600/1601 Direct Injection FoamPro 1600/1601 Direct Injection

Proportioning SystemsProportioning Systems

Edition 1 May 2009Slide – 2

Contamination of the appliance Contamination of the appliance tank tank willwill occur if the occur if the re-circulation valve is open re-circulation valve is open during Class A foam operation.during Class A foam operation.

Retro Fit FoamPro SystemRetro Fit FoamPro System

Foampro systems retro fitted to tankers prior to 1998 utilized the unmodified vehicle water reticulation system.

Edition 1 May 2009Slide – 3

Recirculation valve can be open during Class A foam operation without contamination

Foampro systems fitted to tankers manufactured after 1998 utilized the modified vehicle water reticulation system

Modified Vehicle Water Reticulation System

Edition 1 May 2009Slide – 4

Retro - FitRetro - Fit New 1998 Onward New 1998 Onward

FoamPro

Edition 1 May 2009Slide – 5

New installationRetro fit

re-circulation valve

Edition 1 May 2009Slide – 6

By-pass Valve

Retro-Fit

New Installation

FoamPro

Edition 1 May 2009Slide – 7

Proportioning Methods (FoamPro)Proportioning Methods (FoamPro)

Manually selected proportioning rate 0.1 to 1%Manually selected proportioning rate 0.1 to 1%Then proportioning rate automatically adjusts to the selected Then proportioning rate automatically adjusts to the selected proportioning rate across flow rates of 20-1600 LPMproportioning rate across flow rates of 20-1600 LPMregardless of pressure variationsregardless of pressure variations

NOTE: Depending on the control panel being used, the On / Off NOTE: Depending on the control panel being used, the On / Off positions may be different.positions may be different.

Edition 1 May 2009Slide – 8

Foampro pump is driven by a 24 volt electrical motor. Foampro pump is driven by a 24 volt electrical motor.

appliance motor must be run between 1200 and 1400 appliance motor must be run between 1200 and 1400 rpm while class a foam is in operation to maintain rpm while class a foam is in operation to maintain battery charge rate.battery charge rate.

System Components (FoamPro)

schematic lay out and system components

Edition 1 May 2009Slide – 9

Class A injection pointClass A injection point

Class A concentrate tank supply on/off valveClass A concentrate tank supply on/off valve

Class A concentrate inline strainerClass A concentrate inline strainer

non-return valve non-return valve (obscured from sight )(obscured from sight )

System Components (FoamPro)

Paddle Wheel

Edition 1 May 2009Slide – 10

two valve positionstwo valve positions

• injectinject

• calibrate flushcalibrate flush

““inject” inject”

is for normal operations when the is for normal operations when the correctly proportioned foam concentrate correctly proportioned foam concentrate is “is “injected”injected” into the delivery discharge into the delivery discharge manifoldmanifold

““calibrate flush”calibrate flush”

is used after installation of the system to is used after installation of the system to calibrate the accuracy of the foam pump calibrate the accuracy of the foam pump

This function my also re prime the foam This function my also re prime the foam pump following maintenance or should pump following maintenance or should the foam tank run dry.the foam tank run dry.

inject Calibrate flush

System Components (FoamPro)

Edition 1 May 2009Slide – 11

Direct injection system advantages

simple to operate easily adjusted proportioning rates highly accurate proportioning maintains desired mix ration despite changes in water flow and

pressure proportioning across wide flow range 20 -1600 Lt no foam contamination of pump or appliance water tan no loss of pump flow or pressure number and length of hose is

limited only by the pump capacity concentrate injection will not be interrupted when filling the foam

tank

Direct Injection Systems