zxr10 m6000-s ( v3.00.20 ) products at a glance

17
ZXR10 M6000-S ( V3.00.20 ) Products at a Glance

Upload: khangminh22

Post on 29-Apr-2023

0 views

Category:

Documents


0 download

TRANSCRIPT

ZXR10 M6000-S ( V3.00.20 )Products at a Glance

Product Introduction

ZXR10 M6000-3SZXR10 M6000-5S

ZXR10 M6000-18S

The ZXR10 M6000-S series routers are used as a unified service value-added platform in the backbone network, MAN and mobile bearer network of a network operator to improve network values. The routers can also be used in government, energy, education and enterprise networks. The routers provide the 200 G/400 G solutions and the 1T evolution capability to meet the requirements of operators and government and enterprise customers for service bearing and network evolution.

ZXR10 M6000-8S Plus

Product Positioning

PDSN/GGSN

IPTV

IDC

Internet

Enterprise

HGIPTV

CGN

Video Phone

PC

IGW

P

CR

BackboneMetro

Access

Access

The M6000-S series are used as SR and CGN devices on the control layer at the edges of

metropolitan areas. The routers can also be used as backbone network devices, border

routers, backbone node devices of the vertical networks of governments and enterprises,

and core egress devices.

SR (Service Router)

PC

Mobile

ZXR10 M6000-S

ZXR10 M6000-18S

Front View Rear View

41U

18-Slot System

Main control board: 1+1

Switching board: 6+2

Number of service slots: 18

AC/DC: 8+8/7+1 equalized current power supply modeMaximum power consumption per power module: 2675W(AC)/2400W(DC)Rated input current: 14A (AC)/57A(DC)

Fan module for heat dissipation of service slots:Quantity: 10Number of fans per module: 3Fan module for heat dissipation of switching boards:Quantity: 2Number of fans per module: 2Linear adjustment

ZXR10 M6000-8S Plus

8-Slot System

Main control boards: 1+1,one control unit and one switching unit per board

Switching boards: 3+1,including two switching boards and switching units in the main control boards

Number of service slots: 8

AC/DC: 4+4/5+1 equalized current power supply modeMaximum power consumption per power module: 2675W(AC)/2400W(DC)Rated input current: 14A (AC)/57A(DC)

Fan moduleQuantity: 2Number of fans per module: 11Linear adjustment

22U

Front View Rear View

ZXR10 M6000-3S&M6000-5S

Fan modules are rear mounted, improving space utilization.

4U

5U

Front View

Rear View

7U

8U

M6000-3S M6000-5S

Main control boards: 1+1

Main control boards: 1+1including one main control unit and one switching unit

Number of service slots: 3

Number of service slots: 5

AC power supply module 1+1 redundancyMaximum power consumption: 2675 WRated input current: 14 A

DC power supply module 1+1 redundancyMaximum power consumption: 2500 WRated input current: 53 A

Fan Module Quantity: 2Number of fans per module: 2Linear adjustment

Fan Module Quantity: 3Number of fans per module: 2Linear adjustment

DC power module1+1 redundancyMaximum power consumption: 3420 WRated input current: 72 A

System Architecture

Switching System

Line Card

Data Forwarding UnitData

Forwarding Unit

Control Unit

Control Unit

Monitoring Unit Monitoring Unit

Control Unit

Main Control Board

Control and Management Plane

• Protocol plane: processes protocols and signaling

messages, and generates and maintains routes.

• Management plane: maintains system configurations.

• Internal communication plane: implements information

exchange among internal components.

Monitoring PlaneDetects system errors (such as the power module,

fan, and temperature) and reports alarms.

Data Forwarding PlaneImplements the wire-speed processing and non-blocking forwarding of data packets, includingpacket encapsulation and decapsulation, fastforwarding table lookup processing, QoS and TMprocessing, and cell switching.

ZXROSng Software Platform

4. System faults are detected, handled, and recorded. If any fault occurs, thesystem can immediately perform fault recovery and switchover.

Operation System

Ke

rne

l spa

ce

Basic Drive

… …BGP

User space

MPLS

User space

Multicast

User space

2. The software components belong to independentprocess spaces and implement distributed processing,isolating illegal application operations.

Netflow

User space1. The systemkernel isseparatedfrom softwarecomponents,enhancing thesystemsecurity.

3. Services canbe developedquickly andindependently.Servicecomponentscan bedynamicallyloaded,unloaded, orupgradedonline withoutserviceinterruption,meeting theservicecustomizationrequirements.

Product Features

Stable

Simple

Fast Service provisioning: plug and play, fast

provisioning Large-scale network deployment:

scale expansion in a layered and sectored way

Self-healing upon faults

Wide

Service operation: multi-dimension protection and synchronization mechanism

Upgrade and capacity expansion Attack prevention: ensures device

security and service security

Easy device configuration Easy service adjustment Operation and maintenance analysis

All IPv6 dual-stack integration technologies supported

SDN architecture design, trunking control and virtual access

NSR (Non-Stop Routing)

Switch Fabric

LPCLPC

FIB

RIB RIB

MPU(active) MPU(standby)

• Data forwarding and control plane

protocols not interrupted

• Re-convergence of routes not needed

• Neighbor cooperation not needed

PPP, POS group, Smartgroup…

PIM-SM, PIM-SSM, MSDP, MBGP…

Static route, BGP, OSPF, ISIS, BGP4+, ISISv6…

Layer-2 Protocol Multicast Protocol

Route Protocol

NSR-SupportingProtocols

LDP,PWE3, VPLS, L3VPN, MPLS TE…

MPLS

Link Binding

Intra-Board Inter-Board

Inter-Chassis

LACP MC-LAG

M6000-S

Active

Active-Standby

Redundancy

Standby1:1 redundancy backup for member interfaces

Cover Various Link Bundling Scenarios

No Limit on Service Development

SmartGroup

L2/L3 VPN

VRRP/FRRs

QoS/HQoS

MPLS TE

Unicast/Multicast

BFD/OAM

Overall Link Aggregation Solution

Protection Switchover

TE FRR & VPN FRR Protection

Active LSP PW

Standby LSP PW

LSP & PW Protection

DNI-PW effectively isolates faults on the network and user sides, reducingnetwork management and maintenance costs

Isolating user side faults avoids large-scaletraffic switchover in the whole network.

DNI-PW

Core device

Core device

Isolation of network side faults avoidstraffic switchover of devices on the corenetwork side.

DNI-PW

Core device

Core device

UPE SPE BSC-CETPE

TE FRR TE FRR

VPN FRR

VPN FRR

If the active node or link is faulty, the device automatically switches over traffic to the standby node or link

Security Features

• Traffic filtering: ACL

• Anti-spoofing: address binding, URPF,

and IP snooping

• Account password management

• RADIUS/TACACS+ authentication

and authorization

• Traffic suppression

and attack tracing

• Protocol whitelist

CPU Security

Routing Protocol

Security

• Routing protocol

encryption and

authentication

• Route policy and route

filtering

Packet Attack Prevention

• ARP attack prevention

• IGMP attack prevention

The security features and attack prevention capability of a device are the basis of dealing with network security threats.

Device Security

Graphical End-to-End Configurations

eNB

eNB

Graphical port

configurations

Graphical route

configurations

Interface/Protocol Configurations

Explicit path

configurations

End-to-end tunnel

configurations

TunnelConfigurations

L2 VPN end-to-end

deployment

L3 VPN end-to-end

deployment

ServiceConfigurations

MPLS OAM

management

QoS configurations

OAM/QoSConfigurations

NetNumen™ U31

The visualized configurations of the layer-2 and layer-3 services, OAM, and QoSshield IP protocol details and simplify service provisioning.

Automatic Preventive Maintenance

Auto PreventiveMaintenance

Basic Network Info

Network Configuration Info

Network Operation Status

EMS System Status

The larger the network scale is, the more powerful the preventive maintenance tool is. For a network having 5000 NEs, the preventive maintenance efficiency is increased by 997 times.

Project Name

Number of NEs

ManualMaintenance Time (in Minutes)

Auto Maintenance Time (in Minutes)

Multiple of EfficiencyImprovement

XX China Unicom

111 8388 77 103

XX China Mobile

1061 76392 173 441

XX China Mobile

2124 152928 231 661

XX China Mobile

5000 360000 361 997

EMS

Client

Benefits

Technical Specifications

Specification M6000-18S M6000-8S Plus M6000-5S M6000-3S

Dimensions

(W× H× D)

(mm)

DC442 x 1819.6 x

634

41U

442× 971.5×

678.7

22U

442× 308.3× 74

0

7U

442× 175× 738

4U

AC

442× 352.8× 74

0

8U

442× 219.4× 73

8

5U

Number of slots 28 12 7 5

Number of service slots 18 8 5 3

Main control redundancy 1:1 1:1 1:1 1:1

Switching redundancy 6+2 3+1 1+1 FULLMESH

Rated power per

power module

DC 2400W(7+1) 2400W(5+1) 3420W (1+1) 2500W (1+1)

AC 2675W(8+8) 2675W(4+4) 2675W (1+1) 2675W (1+1)

Long-term operating

temperature-5-45° C

Long-term operating

humidity5-90%

Tel: +86-755-26771900

E-mail: [email protected]

URL: http://supporthk.zte.com.cn

Documentation Development Department

Version: R2.0

Released: 2018-07-10