zxr10 m6000-s ( v3.00.20 ) products at a glance
TRANSCRIPT
Product Introduction
ZXR10 M6000-3SZXR10 M6000-5S
ZXR10 M6000-18S
The ZXR10 M6000-S series routers are used as a unified service value-added platform in the backbone network, MAN and mobile bearer network of a network operator to improve network values. The routers can also be used in government, energy, education and enterprise networks. The routers provide the 200 G/400 G solutions and the 1T evolution capability to meet the requirements of operators and government and enterprise customers for service bearing and network evolution.
ZXR10 M6000-8S Plus
Product Positioning
PDSN/GGSN
IPTV
IDC
Internet
Enterprise
HGIPTV
CGN
Video Phone
PC
IGW
P
CR
BackboneMetro
Access
Access
The M6000-S series are used as SR and CGN devices on the control layer at the edges of
metropolitan areas. The routers can also be used as backbone network devices, border
routers, backbone node devices of the vertical networks of governments and enterprises,
and core egress devices.
SR (Service Router)
PC
Mobile
ZXR10 M6000-S
ZXR10 M6000-18S
Front View Rear View
41U
18-Slot System
Main control board: 1+1
Switching board: 6+2
Number of service slots: 18
AC/DC: 8+8/7+1 equalized current power supply modeMaximum power consumption per power module: 2675W(AC)/2400W(DC)Rated input current: 14A (AC)/57A(DC)
Fan module for heat dissipation of service slots:Quantity: 10Number of fans per module: 3Fan module for heat dissipation of switching boards:Quantity: 2Number of fans per module: 2Linear adjustment
ZXR10 M6000-8S Plus
8-Slot System
Main control boards: 1+1,one control unit and one switching unit per board
Switching boards: 3+1,including two switching boards and switching units in the main control boards
Number of service slots: 8
AC/DC: 4+4/5+1 equalized current power supply modeMaximum power consumption per power module: 2675W(AC)/2400W(DC)Rated input current: 14A (AC)/57A(DC)
Fan moduleQuantity: 2Number of fans per module: 11Linear adjustment
22U
Front View Rear View
ZXR10 M6000-3S&M6000-5S
Fan modules are rear mounted, improving space utilization.
4U
5U
Front View
Rear View
7U
8U
M6000-3S M6000-5S
Main control boards: 1+1
Main control boards: 1+1including one main control unit and one switching unit
Number of service slots: 3
Number of service slots: 5
AC power supply module 1+1 redundancyMaximum power consumption: 2675 WRated input current: 14 A
DC power supply module 1+1 redundancyMaximum power consumption: 2500 WRated input current: 53 A
Fan Module Quantity: 2Number of fans per module: 2Linear adjustment
Fan Module Quantity: 3Number of fans per module: 2Linear adjustment
DC power module1+1 redundancyMaximum power consumption: 3420 WRated input current: 72 A
System Architecture
Switching System
Line Card
Data Forwarding UnitData
Forwarding Unit
Control Unit
Control Unit
Monitoring Unit Monitoring Unit
Control Unit
Main Control Board
Control and Management Plane
• Protocol plane: processes protocols and signaling
messages, and generates and maintains routes.
• Management plane: maintains system configurations.
• Internal communication plane: implements information
exchange among internal components.
Monitoring PlaneDetects system errors (such as the power module,
fan, and temperature) and reports alarms.
Data Forwarding PlaneImplements the wire-speed processing and non-blocking forwarding of data packets, includingpacket encapsulation and decapsulation, fastforwarding table lookup processing, QoS and TMprocessing, and cell switching.
ZXROSng Software Platform
4. System faults are detected, handled, and recorded. If any fault occurs, thesystem can immediately perform fault recovery and switchover.
Operation System
Ke
rne
l spa
ce
Basic Drive
… …BGP
User space
MPLS
User space
Multicast
User space
2. The software components belong to independentprocess spaces and implement distributed processing,isolating illegal application operations.
Netflow
User space1. The systemkernel isseparatedfrom softwarecomponents,enhancing thesystemsecurity.
3. Services canbe developedquickly andindependently.Servicecomponentscan bedynamicallyloaded,unloaded, orupgradedonline withoutserviceinterruption,meeting theservicecustomizationrequirements.
Product Features
Stable
Simple
Fast Service provisioning: plug and play, fast
provisioning Large-scale network deployment:
scale expansion in a layered and sectored way
Self-healing upon faults
Wide
Service operation: multi-dimension protection and synchronization mechanism
Upgrade and capacity expansion Attack prevention: ensures device
security and service security
Easy device configuration Easy service adjustment Operation and maintenance analysis
All IPv6 dual-stack integration technologies supported
SDN architecture design, trunking control and virtual access
NSR (Non-Stop Routing)
Switch Fabric
LPCLPC
FIB
RIB RIB
MPU(active) MPU(standby)
• Data forwarding and control plane
protocols not interrupted
• Re-convergence of routes not needed
• Neighbor cooperation not needed
PPP, POS group, Smartgroup…
PIM-SM, PIM-SSM, MSDP, MBGP…
Static route, BGP, OSPF, ISIS, BGP4+, ISISv6…
Layer-2 Protocol Multicast Protocol
Route Protocol
NSR-SupportingProtocols
LDP,PWE3, VPLS, L3VPN, MPLS TE…
MPLS
Link Binding
Intra-Board Inter-Board
Inter-Chassis
LACP MC-LAG
M6000-S
Active
Active-Standby
Redundancy
Standby1:1 redundancy backup for member interfaces
Cover Various Link Bundling Scenarios
No Limit on Service Development
SmartGroup
L2/L3 VPN
VRRP/FRRs
QoS/HQoS
MPLS TE
Unicast/Multicast
BFD/OAM
Overall Link Aggregation Solution
Protection Switchover
TE FRR & VPN FRR Protection
Active LSP PW
Standby LSP PW
LSP & PW Protection
DNI-PW effectively isolates faults on the network and user sides, reducingnetwork management and maintenance costs
Isolating user side faults avoids large-scaletraffic switchover in the whole network.
DNI-PW
Core device
Core device
Isolation of network side faults avoidstraffic switchover of devices on the corenetwork side.
DNI-PW
Core device
Core device
UPE SPE BSC-CETPE
TE FRR TE FRR
VPN FRR
VPN FRR
If the active node or link is faulty, the device automatically switches over traffic to the standby node or link
Security Features
• Traffic filtering: ACL
• Anti-spoofing: address binding, URPF,
and IP snooping
• Account password management
• RADIUS/TACACS+ authentication
and authorization
• Traffic suppression
and attack tracing
• Protocol whitelist
CPU Security
Routing Protocol
Security
• Routing protocol
encryption and
authentication
• Route policy and route
filtering
Packet Attack Prevention
• ARP attack prevention
• IGMP attack prevention
The security features and attack prevention capability of a device are the basis of dealing with network security threats.
Device Security
Graphical End-to-End Configurations
eNB
eNB
Graphical port
configurations
Graphical route
configurations
Interface/Protocol Configurations
Explicit path
configurations
End-to-end tunnel
configurations
TunnelConfigurations
L2 VPN end-to-end
deployment
L3 VPN end-to-end
deployment
ServiceConfigurations
MPLS OAM
management
QoS configurations
OAM/QoSConfigurations
NetNumen™ U31
The visualized configurations of the layer-2 and layer-3 services, OAM, and QoSshield IP protocol details and simplify service provisioning.
Automatic Preventive Maintenance
Auto PreventiveMaintenance
Basic Network Info
Network Configuration Info
Network Operation Status
EMS System Status
The larger the network scale is, the more powerful the preventive maintenance tool is. For a network having 5000 NEs, the preventive maintenance efficiency is increased by 997 times.
Project Name
Number of NEs
ManualMaintenance Time (in Minutes)
Auto Maintenance Time (in Minutes)
Multiple of EfficiencyImprovement
XX China Unicom
111 8388 77 103
XX China Mobile
1061 76392 173 441
XX China Mobile
2124 152928 231 661
XX China Mobile
5000 360000 361 997
EMS
Client
Benefits
Technical Specifications
Specification M6000-18S M6000-8S Plus M6000-5S M6000-3S
Dimensions
(W× H× D)
(mm)
DC442 x 1819.6 x
634
41U
442× 971.5×
678.7
22U
442× 308.3× 74
0
7U
442× 175× 738
4U
AC
442× 352.8× 74
0
8U
442× 219.4× 73
8
5U
Number of slots 28 12 7 5
Number of service slots 18 8 5 3
Main control redundancy 1:1 1:1 1:1 1:1
Switching redundancy 6+2 3+1 1+1 FULLMESH
Rated power per
power module
DC 2400W(7+1) 2400W(5+1) 3420W (1+1) 2500W (1+1)
AC 2675W(8+8) 2675W(4+4) 2675W (1+1) 2675W (1+1)
Long-term operating
temperature-5-45° C
Long-term operating
humidity5-90%
Tel: +86-755-26771900
E-mail: [email protected]
URL: http://supporthk.zte.com.cn
Documentation Development Department
Version: R2.0
Released: 2018-07-10