HVAC-R* SYSTEMS FORPASSENGER VESSELS

* Heating, Ventilation, Air-Conditioning & Refrigeration Systems

2

We have always been an independent company, proud of our strength and ability to perform complex tasks. Our entrepre-neurial spirit is characterized by the ability and willingness to think differently and find better, more future-oriented ways in which to generate value. AF- Addressing Future!

AF Offshore AeronMollier AS

AF Offshore AeronMollier is a part of the Offshore division in AF Gruppen. We are a total contractor of complete Heating, Ventilation and AirConditioning - HVAC Systems to the global Marine and Offshore Industry. We design and deliver advanced energy efficient HVAC-R Systems with focus on safety and environmental friendly solutions.

Your Reliable HVAC-R Partner

We are offering our products and services for marine and offshore newbuilding’s, maintenance and modification projects. We offer support for every stage in the projects from conception to completion, and we want to be involved at all stages of the building process and for the lifetime of installed systems. Our goal is to be a reliable worldwide HVAC partner for our customers, ensuring optimal indoor climate for our customer’s installations all over the world.

Our core values

The purpose of our business is to create value for our customers, owner, employees, suppliers and society. Our attractiveness is demonstrated by how we create and manage value.

• Reliable • Freedom to exercise entrepreneurial spirit and discipline in rela-

tion to goals and requirements • Thoroughness and hard work • Persistence in achieving profitable growth• Management through presence and involvement

Code of conduct

AF’s Code of Conduct serves as the standard for the expectations and demands we make of our suppliers and subcontractors. In 2009, AF joined the United Nations Global Compact, which is based on ten fundamental principles for safeguarding human rights, working conditions, the environment and anti-corruption measures.

AF GruppenAF Gruppen is one of Norway’s leading contracting and industrial groups with operations in the areas of Civil Engineering, Environment, Building, Property, Energy and Offshore. The company was founded in 1985 and is listed on Oslo Stock Exchange in Norway.

3

The name Aeron is the Greek word for air. Air is the base element in all HVAC systems. The AERON logotype is a composition of arrows who symbolize the process of putting a multiplicity of HVAC products together. These different bits transforms into a complete AERON HVAC system. The arrows in the logotype forms a star who symbolizes the high quality of the AERON HVAC systems. The AERON brand name is the customer’s guarantee for the quality that goes into every single part of our systems

AERON® HVAC-R Products

AERON® is a well known brand in the global marine and offshore industry. Since 1979, we have developed an AERON® high quality product range, specially designed for shipboard and offshore environments. AERON® HVAC+R products are designed to ensure optimal climate solutions for passengers, personnel, cargo, machinery and instruments aboard modern passenger ships.

Multi brand equipment

We complete our product range with products from other well-known suppliers, in order to give our customers the optimal solutions and fulfil our customers’ requirements. We select equipment that is right for the application and the environment where the asset will be deployed.

You will find more information in our standard product catalogue at our web site www.aeron.no

The Feeling of Fresh AirIt is a known fact how important a well dimensioned HVAC system is for the indoor environment. Fresh air is vital to both personnel and machinery. Feeling good improves productivity.

With AERON® HVAC Products installed - you are sure to get the feeling every hour, every day, every year and all around the world – The Feeling of Fresh Air...

Wide ExperienceWe have been delivering successful AERON HVAC Systems to the marine and offshore industry since 1979 and we have a good track record of solving our customer challenges in an innovative way. We have wide experience and knowledge in complex newbuilding projects and modifications of existing HVAC installations. We cover all kind of projects from small fishing vessels to large offshore projects and passenger vessels operating both in cold and tropical areas.

4

AF Offshore AeronMollier offer the international markets customized solutions and global after-sales service. Our products and services are distributed worldwide through a network of subsidiaries and carefully chosen representatives. With our long experience, and deliveries to more than 1.000 installations worldwide, we are a leading contractor of HVAC-R systems to the global marine and offshore industry.

Norway, Close to the North Sea

With offices in Flekkefjord, Stavanger and Bergen along the Norwegian coast, and in Aberdeen in the UK, we are very close to the Norwegian and British Marine and Offshore business. We are well familiar with the demanding national authorities requirements in the North Sea, Norsok standards, the oil companies and classification societies requirements. We are able to serve our customers in order to fulfil these requirements.

Aeron Energy Technology Co Ltdin p.r. China

We have since 2000 delivered complete HVAC-R Systems to more than 150 Ships built in China. Aeron Energy Technology Co Ltd was established in 2009 and is our main HVAC centre in Asia, serving our customers in the marine and offshore industry in China and part of Asia.

AF Offshore Aeron Pte Ltd in Singapore

We have been operating in Singapore since 2007 and we have been a contractor of several turnkey HVAC-R projects both for the Marine and Offshore Industry. In 2014, we established AF Offshore Aeron Pte Ltd in order to get closer to our customers in the region and be able to give them even better services.

Your Local and Global HVAC-R Partner

North SeaShanghai Singapore

5

HSE - Health, Safety and Environment

In the marine and offshore industry, HSE is a major focus area. HSE and QA is an integrated part of our working methods and routines. It is a requirement at AF that all work must be performed such that the safety and health of those who are involved are looked after in a satisfactory manner. This is an obligation of our managers, employees and subcontractors. We base our philosophy on the precondition that all work must be planned and carried out such a way that no damage occurs to people, machines or environment.

The management system at AF integrates health, safety and environment (HSE) in all processes. The system is constructed in accordance with the principles in the ISO standards 9001, 9004 and 14001. HSE work is extremely central in the development of managers and employees.

Preventive work is fundamental in order for us to be successful with HSE in our projects. Job Analysis and Safe Job Analysis (SJA) are tools that we use to survey the risks with respect to the HSE and in order to plan production in the safest and most appropriate manner. Through participation in SJA, everyone becomes aware of their tasks and the risks associated with such.

Quality Assurance

The Group policy defines quality as one of the elements in the AF Group’s operational strategy. AF Offshore AeronMollier AS is focusing on a good reputation, created by satisfied customers. Therefore, a well-functioning handed over system with correct standards is our understanding of the word quality. Our ambition is that every plant/system we deliver, shall comply with our customers’ specification.

When doing a job, we understand both the risks and opportunities involved and know how to manage them. We take pride in delivering as we promise. From the very start of the engineering process, quality is a key word during the whole process of any project. AF complies with relevant standards and authorities for the market segments and geographical locations in which we operate.

The management system of AF Offshore AeronMollier is certified by Det Norske Veritas – DNV according to ISO 9001:2008.

HSE and Quality ControlOur mission is to create value through future-oriented contracting, energy and environmental operations with an uncompromising attitude towards safety and ethics.

6

Most people would agree that it is important to protect the environment, and there is an increasing focus on “green ships”. We believe that even more investments in green solutions would be made if these were also cost effective.

A good indoor climate improves wellbeing and productivity, and prolongs the lifetime of the technical equipment. The passengers has high expectations of comfort, safety and reliability both when sailing in the tropics or in cold climates.

The HVAC System is one of the main consumers of generated energy on a modern passenger vessel, and a major driver of operating cost. Energy efficient solutions is therefore increasingly important within the passenger market.

Our commitment is to provide smart and energy efficient HVAC Systems that will benefit both our customers’ investments and the environment even with the most demanding global comfort and safety requirements. We call it the Blue Environmental Effect.

AERON® Energy Efficient Solutions – “Blue Environmental Effect”

Since the start in 1979, our Heating, Ventilation and Air-Conditioning - HVAC Systems, have been installed on more than 1 000 vessels worldwide. We are handling HVAC assignments on newbuildings, maintenance, modifications and conversions. As a total contractor of HVAC systems, we take full responsibility for all steps in a project, in order to give our customer the optimal climate solution for personnel and machinery.

We are a reliable contractor of advanced Heating, Ventilation and Air-Conditioning – HVAC systems. Our engineers are highly qualified and experienced, with in-depth knowledge of international rules and regulations of all leading classification societies. Our dedicated specialists have extended knowledge of the demanding marine rules and regulations. With highly skilled employees in all disciplines, we take the complete responsibility for our customers HVAC-R Systems from Conception to Completion.

HVAC-R Systems from Conception to Completion

7

EngineeringOur highly skilled engineers have wide experience in large complex newbuilding projects and extensions & modifications of existing HVAC installations.

One of the main ways to ensure high quality standards is project management. Our staff has many years of experience in the business and a proven track record of their skills. We provide complete project management services according to the needs of the client, from refitting of small vessels to complete new build of HVAC Systems for large vessels and offshore installations

We deliver a complete package of services related to engineering of marine HVAC-R projects, including, but not limited to the following items:

• Total project execution of HVAC-R projects – EPCIC• Complete design and supply of HVAC-R systems• Calculations of all heat transmissions, airflows, heating and cool-

ing capacities• Complete Automation for all HVAC-R Systems, including PLC

based Control panels.• Complete design and supply of chilled water and DX refrigeration

plants• Complete design and supply of Provision room refrigeration• Complete pre-fabricated freezer and cold storage packages• Calculations and supply of all ventilation for Machinery, Cargo, &

technical rooms• Noise and pressure loss calculations • All necessary documentation for installations, operations and

maintenance.

Procurement & ConstructionBased on more than 35 years of experience, we have developed a large range of AERON® high quality product range, specially designed for shipboard and offshore environments. Carefully selected OEM manufacturers produce our products according to our strict require-ments and quality standard.

We complete our AERON product range with products from other well-known suppliers, in order to give our customers the optimal solutions and fulfil their requirements. Our engineers select equipment that is optimal for the application and the environment.

All materials used by AERON come from reliable suppliers and are certified to the highest standards

Our purchasing department ensures that all the equipment are delivered at the right time, at the right place and with the right quality.

Installation and SupervisingBy using our own well-experienced supervisors together with local partners in different countries, we may offer turnkey solutions that includes the installations of your HVAC Systems. For instal-lation services, we only engage well-qualified suppliers with great experience in assembling the ventilation systems in accordance to our customers and classification requirements, which is the key to the proper functioning and long life of the system. Our flexible approach, services and careful attention to details are well known among our customers.

Newbuildings

8

Our Maintenance and Modification -M&M Department is the customer’s link and lifeline to service, maintenance and spare parts for HVAC-R Systems. Regular follow-ups of systems in operation are offered to all our customers. As when it comes to supervision and suggestions for alterations and improvements of systems, whenever regulatory authorities require it, or when new and better technology is available, our M&M department will be at your service.

Maintenance and service is vital to ensure optimum air quality and long life for the HVAC-R plants. We offer both service “on demand” and a range of service agreements, which can be adapted to customer requirements. Aeron will be at your service with professionals ready to analyze and solve any problem before they become critical.

We deliver a complete package of M&M services related to HVAC-R projects.

• Supervising and inspections• Commissioning• Operator training• Preventive maintenance• Modifications, upgrading and conversions• Complete Equipment deliveries of HVAC-R Systems• All necessary documentations for HVAC-R Systems• Noise and vibration reductions• Cleaning of ducts and equipment• Readjustments of the plants• Pressure control of HVAC Systems for accommodation• Energy efficient temperature control of technical rooms• Temperature and pressure control of engine room fans• Cleaning and control of water flow for cooling and heating

Spare parts

To maintain smooth operation and minimal downtime of the installed equipment, we hold an extensive stock of spare parts available. In conjunction with our international representatives and business partners we do our utmost to satisfy our customers needs.

• An extensive stock of filters and spare parts available• AERON® air filters and coal filters available in our warehouse.• Quality spare parts with attractive prices• Spare parts sent by courier same day as ordered• Worlwide service network • Experienced marine service engineers at your service

Flat Packed HVAC-R Products

We have developed a special system which makes it possible to supply ‘flat-pack’ HVAC equipment as an alternative to fully assembled. This unique system means that the units can be taken into the ventilation compartment in pieces, and assembled there. This saves a lot of time and cost, compared to cutting a hole in the hull to take in large products.

Neither does the work has to be performed at a shipyard. Much work can be done anywhere in the world, and even while the ship is in transit. We upgrade and install the HVAC-R products all over the world and we take full responsibility for the complete upgrading and installation for all disciplines related to the upgrading of the HVAC-R System.

Maintenance & Modifications

Air terminals for Cabins and Public SpacesAERON® Marine Cabin Units and air terminals are designed for use in low and high speed marine air conditioning systems. Their task is to control the airflow and temperature. We have a comprehensive range of Cabin Units for wall mounting or ceiling suspension, units for 1-pipe, 2 pipe, 1 pipe with reheat and a wide selection of air terminal units

The manually operated cabin units includes a reheater with room thermostat, or just a manual damper (manual model) which both allow the manual adjustment of airflow quantity. The Cabin Units includes a selection of room thermostats and diffusors.

We may also offer automatic pressure-independent cabin units that support the most sophisti-cated indoor environment in cabins. The airflow can be controlled and maintained individually in each cabin and thus sound levels and comfort are kept in a best possible level. The airflow and temperature can be continuously measured so that the controller will cut off the reheat power below the minimum airflow. Some Marine cabin units can operate on a LON or Ethernet network with a dedicated network adapter. Through intelligent network and pressure-independent operation systems it is possible to reach the best benefits of energy efficiency technology.

Advanced energy efficiency solution (VAV)One of the best benefits from the owner’s point of view is active operation between the AHU (Air Handling Unit) and the terminal units. Data from terminal units is collected and used to control the AHU in two ways.

1. Adjusting the fan operation to optimal level2. Minimizing the need to heat or cool down the air inside the AHU

AERON® Single duct Cabin Unit ACU1-30C

AERON® Dual duct Cabin Unit ACU2-50C

10

Local energy efficiencyAir conditioning could be forced into standby mode when the passenger removes the keycard from its holder. Even though unnecessary cooling and heating is limited while the cabin is not occupied, the indoor climate conditions are simply maintained at a comfortable level. The individual comfort level is quickly re-established when the passenger returns to cabin. If the passenger opens the balcony door, the cabin ventilation unit saves energy by preventing unnecessary cooling. Unlike advanced system, the local solution does not require a network

Automatic operation could be facilitated by continuous airflow measurement and damper regulation by intelligent control panel. Automatic HFR/M adapts to variations in ductwork pressure and maintains individual conditions in each cabin and is thus pressure independent. Semi-automatic cabin unit does not include airflow measurement and is thus pressure dependent. The HFR/M is an excellent choice for suites, deluxe cabins and office areas where the total airflow needs to be distributed to several points, but controlled centrally with one control panel.

Monitor your cabin comfort and savingsWe may offer supervision software that runs on a computer and offers an excellent tool for HVAC engineers and hotel management. The software offers and overview from a cabin ventilation system, to each cabin that can be individually adjusted, controlled and monitored via network. The software enables the changing of parameters and set-points, for individual cabins or for cabin groups, as well as printed listings of different elements that have a direct impact on indoor climate conditions, safety and energy-efficiency. The supervision system can also display the history data and trends. Symbolic representation of the process and clear displays make the software easy and convenient to use

Multi Connection Cabin Unit type HFR/M

Airflow unit for large volumes type HML

11

AERON® Refrigeration PlantsThe range of AERON® refrigerating products will cover every need for refrigeration onboard modern ships and offshore installations. All refrigeration machineries and cooling products will be delivered according to requirements from yards, owners, classification society, and national authorities.

Our refrigeration machineries are constructed for marine and offshore applications. Compo-nents and materials are based on our customers’ requirements and our long experience in the business. Emphasis is put on safety, energy efficiency, small dimensions, low weight and easy maintenance as well as site installation-friendly solutions.

The refrigeration plants can be delivered either as direct expansion systems or as chilled water plants for indirect cooling. Our plants can be delivered with air-cooled or water cooled condensers, compressors for reciprocating or screw type systems, or as multi compressor units fitted with several compressors. Whatever the requirements, we will provide an optimal designed plant that meet your demands.

Our refrigeration products may be delivered for the following applications

• Air cooled or water-cooled Chilled water refrigeration units – CW.• Air cooled or water-cooled Refrigeration units with direct expansion – DX.• Air cooled or water-cooled Split AC units for ATEX or non-ATEX.• Fan coils for Chilled water or air-cooled refrigeration units.• Complete Provision room refrigeration plant• Self Contained Units for return air or fresh air supply.• Compact Deck units with Air Handling Units and refrigeration units built together.

AERON® Chilled Water Refrigeration Unit

AERON® Chilled Water Refrigeration Unit

12

AERON® Fan Coils (FCU) and Self Contained Units (SCU)

AERON® Antenna Cooling Units

The AERON® range of Self Contained Units and Fan Coils solutions for demanding marine applications may provide individual air-conditioning in the room by automatic temperature control. The FCU and SCU units normally recirculates the air in the cabin, and some includes necessary fresh air supply.

The vertical fan coils for Cabins have been specifically designed for silent cabin comfort with sophisticated air treatment and control. An advanced digital room temperature control system with stepless fan speed control and heating/cooling power regulation completes the solution. To ensure easy installation in prefabricated cabins, FCU can be installed e.g. in the toilet block in the vertical position. In addition to better sound attenuation, this offers easy access to the unit without disturbing passengers

We can offer FCU and SCU units for the following marine applications:

• Fan Coils for Cabins, vertical or horizontal types• FCU or SCU for Public areas • FCU or SCU for technical rooms• FCU or SCU Cabinet units for public rooms and technical-/ data rooms

AERON® Antenna unit type AM is a light-weight, compact cooling unit designed for cooling of antenna systems. The AM unit is equipped with compressor, evaporator and air-cooled condenser all fitted together in a ”ready to use” unit.

The AM can operate at surrounding temper-atures up to 65˚C. The units will be delivered with thermostat and complete control panel for easy operation.

The AM Unit is a compact, flexible and quiet running air-condition unit. The unit is designed to operate inside or below radar domes in a non EX zone. The unit normally has a cooling capacity of 2,5 - 3.5 kW.

The unit is built in stainless steel chassis AISI 316 quality for long lasting lifetime. The construction is strong due to the harsh environment often found in demanding marine and offshore installations.

Vertical Fan Coil Unit for Cabins FCU

AERON® Fan Coil Cabinet AFCU-CW-B

AERON® Self Contained Unit ASCU E32 Plenum

AERON® Antenna cooling unit AM-05

13

AERON® Air Handling Units (AHU) are designed to supply sufficient amount of clean fresh air with necessary heating and cooling capacities for all kind of accommodation spaces in passenger vessels. Our AHU units provide clean comfort by bringing fresh outside air into your interior spaces.

We offer a flexible range of units. The units are constructed with modules that enable us to deliver solutions tailor made to each vessel. The AERON® Marine Air Handling Units are delivered with all necessary accessories in order to minimize installation work at the yard. The heat exchangers and evaporators can be delivered in any type of materials the customer demands. The Air Handling Units can be delivered in Alu Zink, galvanized or stainless steel.

AERON® Marine Air Handling Units:

• can be delivered in Alu Zink, galvanized or Stainless steel AISI 316• may be delivered with marine Enthalpy recovery unit• are assembled from a wide range of standard sections• are available in 12 sizes up to 51000 m3/h• have very good acoustic and thermal insulation• are delivered with wave breakers and water traps for optimal drainage. • fan and motor are mounted on vibration dampers with flexible connections

Automation and Control Systems Exclusive automation systems for HVAC-R systems contribute to higher productivity in friendly working environments and energy saving. To control the HVAC-R systems we deliver everything from simple, virtually maintenance-free plants to state of the art PLC and computerized systems. All necessary control panels, starters, frequency converters systems, valves, motors, sensors and other accessories necessary for controlling and monitoring of our HVAC systems.

The HVAC automation system is made for dedicated control of each AHU and can be connected to Cabin Units and Fan Coil units for monitoring of all temperatures, fans, dampers, valves and sensors. For the overall control functions of the HVAC system, the system may be connected to the ships main computer system (IAS) and be delivered with backup systems according to our customers’ requirements.

AERON® Air Handling Units and Automation

AERON® Control Panel with PLC and touch screen

AERON® Air Handling Unit in galvanized steel

AERON® Air Handling Unit in stainless steel AISI 316

AERON® Control Panel App

14

AERON® Weather Louvers and Droplet SeparatorsHumidity does more damage than most people realize. Humidity leads to corrosion, which will shorten the lifespan of machinery, metal structures, electrical installations and electronic systems.

Installation onboard offshore platforms and various types of ships are often exposed to extreme environmental conditions. Louvers in general, particular the intake louvers are often exposed to larger amounts of water from heavy rain, strong winds, green sea and water spray. To ensure the longevity of the louvers, but also to increase the lifespan and performance of machinery, electronic systems and more, a well-dimensioned and high efficient intake louver systems is always well invested money.

AERON® droplet separators are heavy duty, high efficient water and moisture eliminators that yield high efficiency with low operating pressure drop. The separators are available in sea water resistant aluminum alloy or in stainless steel. The droplet separators can be combined with a filter coalesces system for water and dust separation.

All our louvers and droplet separators that can be delivered in combination with a damper or hatch for weather-tight closing. In addition to the advanced moisture eliminators, we also supply all kind of simple louvers, hoods and goose necks.

The AERON droplet separators configurations:

• Droplet separators - singe stage• Droplet separators – 2 stage with filter (Plane or bag filters, G4 or F7) • Produced in sea water resistant aluminum or stainless steel• In combination with weather tight hatch, closure damper or fire damper• In combination with self-regulating heating cable to prevent ice and snow.

AERON® High efficiency louver with hatch

Principle of AERON® 2 stage Droplet Separators with bag filters

15

Galley VentilationKitchen ventilation is one of the key pieces to a well-designed kitchen. Why is kitchen ventilation so important? A great acronym for this is HOGS. HOGS stands for Heat, Odor, Grease, Smoke and Steam. All of these cooking by-products contribute to fire danger, increased humidity and temper-ature, more cleaning, and unpleasant smells. To eliminate HOGS, an appropriate venti-lation system must be installed. The kitchen may also be a large consumer of energy, so smart kitchen solutions may considerably reduce your energy cost.

Aeron may deliver different kind of solutions for kitchen ventilation for use in marine and offshore applications. From smart solutions for smaller accommodations as well as advanced and high efficient solutions for larger passenger vessels. The gally hoods are standard delivered in stainless steel with grease filters at the exhaust airflow.

The galley hoods could be delivered with washing systems for grease filters without the need for removal of the filters from the hood. The washing cycle, operated by

a control cabinet, is fully automatic and programmable for use in different operating conditions. The washing process can be manually overridden, when required.

Configuration examples:

• Simple hoods for exhaust air • Hoods for supply and exhaust air • Hoods for supply and exhaust air with

UV light• Hoods with automatic washing system• Energy efficient hoods with lower airflow

rates.

Galley Water Wash Hood with Supply Air - KWT

A0 (A60) Fire and Gas Damper FDB2

16

AERON® Fans, Fire Dampers and SilencersWe are offering all types of fans needed to create an optimal ventilation system for marine and offshore applications. With requisite certificates according to class and governmental requirements.

Axial Fans

Typical applications for these fans are mechanical ventilation of technical rooms like engine rooms, cargo rooms a.o. where you transport large air volumes at relative small pressure drops.

Explosion- Proof Fans forHazardous Area

Hazardous areas onboard offshore rigs, chemical tankers, oil tankers and gas carriers have very stringent requirements with regard to design and execution of the ventilation fans concerning safety. We offer a wide range of special fans for installation in hazardous areas.

Centrifugal Fans

Typical applications for these fans are exhaust air from different rooms in accom-modation areas or as supply or exhaust fans for any room with narrow spaces that requires small ducts with high speed air distribution.

Dampers and Fire-dampers

We deliver any types of heavy duty dampers for marine and offshore applications, including sertified fire-dampers approved by classification societies.

Silencers

We deliver any type of square and circular high efficiency silencers.

AERON® Axial Fan with Silencer

AERON® Axial Fan with Flexible Connections

17

18

References Passenger Ships

1. Loch SeaforthOwner: Caledonian Maritime Assets Ltd.Shipyard: Flensburger Shiffbau GesellshaftDesign: FSG - FlensburgerType: Ro-paxYear: 2014

2. M/F FjordveienOwner: Stavangerske AS, NorwayShipyard: Flekkefjord Slipp & Maskinfabrikk AS, NorwayType: FerryYear: 2001

3. Twin City LinerOwner: MOBIX Vermögensver-waltung GmbHShipyard: Båtservice Mandal AS, NorwayType: High Speed CatamaranlYear: 2007

4. MS SyltExpressOwner: Förde Reederei Seetouristik GmbH & Co.KG, GermanyShipyard: Fiskerstrand Verft AS, NorwayType: FerryYear: 2012

1

2 3

4 5

5. H/S Dodekanisos PrideOwner: Dodekanisos Seaway, GreeceCustomer: Båtservice Mandal; NorwayType: High Speed CatamaranlYear: 2006

6. MS SpitsbergenOwner: Hurtigruten ASACustomer: Fosen Yard ASMaintenance & ModificationsType: Ro-paxYear: 2016

7. M/V Stena TravellerOwner: Stena Line, NorwayShipyard: Fosen Mek. Verksteder, NorwayYear: 2006Type: Ro-Pax Vessel 212m

8. SuperSpeed 1 & 2Owner: Color Group ASACustomer: Color LineMaintenance & ModificationsType: Ro-pax Year: 2015

We have a complete reference list available upon request.

6

7

8

Photo Montage Kristine Øksnes / Hurtigruten

19

HEAD OFFICE

AF Offshore AeronMollier AS

Nulandsvika 8

N-4400 Flekkefjord

Norway

Phone: +47 38 32 78 00

Telefax: +47 38 32 78 01

E-mail: [email protected]

BRANCH OFFICE

AF Offshore AeronMollier AS

Centurion Court

North Esplanade West

Aberdeen, AB11 5QH

United Kingdom

Phone: +44 1224517840.

Mobile: +44 454685698

E-mail [email protected]

www.aeron.no

www.afgruppen.com/offshore

BRANCH OFFICE

AF Offshore AeronMollier AS

Forusbeen 210

N-4313 Sandnes

Norway

Phone: +47 51 96 26 00

SUBSIDIARY

AF Offshore Aeron Pte Ltd.

Tradehub 21,

18 Boon Lay Way #06 – 108

SG-609966 Singapore

SINGAPORE

Phone: +65 6846 8180

BRANCH OFFICE

AF Offshore AeronMollier AS

Sjøkrigsskoleveien 15

N-5163 Laksevåg

Norway

Phone: +47 55 38 80 80

SUBSIDIARY

Aeron Energy Technology Co Ltd

Flat 7,

530 Huicheng Road,

Huinan County, Pudong District,

201300 Shanghai

P.R. China

Phone: +86 21 52282590

Telefax: +86 21 52286173

E-mail: [email protected]

www.aeron.no

Your local and global HVAC partner

Addressing Future