dk300 series usermanual - wordpress.com...-1-t h ank sf o ry u igt ev m cp l z d inverter produced...
TRANSCRIPT
Dk300 Series
usermanual
Engraving machine specialized inverter
-1-
Thanks for your using the engraving machine specialized
inverter produced by our company. This manual will be helpful in the installation, parameter setting,troubleshooting, and daily maintenance of the AC motor drives. To guarantee safe operation of the equipment,read the following safety guidelines before connecting power to the AC drives. Keep this operating manual handy and distribute to all users for reference.
★ Wiring can only be done after the mains input is cut off, otherwise there will be danger of electric shock.
★ Please connect the inverter to the ground according to the standard, otherwise there will be danger of electric shock
★ Do not connect the input terminals with the output terminals (U, V,W), otherwise the inverter may be damaged!
★ Please confirm the mains voltage level is consistent with that of the inverter and the input andoutput wirings are correct, and check if there is any short circuit in peripheral circuit and if thewiring is fixed and fast, otherwise the inverter may be damaged!
★ Please repair or maintain the inverter after confirming the charge LED turns off, otherwise there may be human injury caused by the residual voltage of the capacitor!
Matters need attention:
Preface
Appendix A Dimensions and Standard Specifications
-2-
3
4
7
10
Catalogs
一、Specification Model
二、Basic Wiring Diagram
三、Function Parameters List
2.
AC Drive Model
DK300 - 1R5 - 4 - XX
1.Description of AC Motor Drive Model:
2.1 INPUT 220V(AC)
2.2 INPUT 380V(AC)
-3-
Series name:DK300 Series
Applicable motor capacity: 1R5 = 1.5KW
Input voltage: 2-220V 4-380V
Technical version number or custom version number
AC Drive Model
AC Drive Model Rated Power(KW) Rated Input Current(A) Rated Output Current(A) Applicable Motor(KW)
Input 1/3PH 220V±15% 47Hz~63Hz
Input 3PH 380V±15% 47Hz~63Hz
Rated Power(KW) Rated Input Current(A) Rated Output Current(A) Applicable Motor(KW)
一、Specification Model
-4-
Braking resistor
FIG.1
二、Basic Wiring Diagram
1、Basic Wiring Diagram
Users must connect wires according to the following circuitdiagram shown below.
(P2.01~P2.06)
(P2.22)
(P2.19~P2.20)
(P2.21)
SW 1: Choose a switch for the fixed source by frequency instruction
WR: Panel Potentiometer issues the frequency instruction
VI: Terminal external potentiometer issues the frequency instruction
SW 2: Simulate the signal input switch
VI: Voltage 0-10V signal input
CI: Current 0-20mA signal input
SW 3: Simulate the signal output switch
V: Voltage 0-10V signal output
C: Current 0-20mA signal output
SW 4: Bipolar signal input switch
PNP: Multi-function input(S1-S6), the public port is connected with DCM terminal
NPN: Multi-function input(S1-S6), the public port is connected with EV terminal
2、Bit switch instructions
-6-
4、Control Terminals and Wiring
4.1 Layout of Control Terminals
4.2 Function of Control Terminals:
3、Main Circuit Termina ls of Inver ter
Refer to P1.10~P1.12
Refer to P0.20~P0.25
P1.13
三 、Function Parameters List
-7-
Function Code Name Setting Range Default Value
Basic Function Parameters
Command source selection0:Keyboard
1:Terminal
Frequency command Selection
0: Keyboard1: VI2: CI4: Multi-speed
Maximum output frequency
Upper limit frequencyLower limit frequencyKeyboard frequency setting
ACCEL time 1DECEL time 1
Operation direction selection
Carrier frequency stting
Functional parameters restoration
0: Operating at default direction1: Operating at reverse direction2: NO inverse operating
0: NO operation1: Restore default value2: Delete failure records
Set by model
Set by model
Set by model
Set by model
Set by model
Set by model
Start frequencyMotor rated power
Motor rated frequencyMotor rated speedMotor rated voltageMotor rated current
Terminal command protectionwhen power on
0: Terminal command invalid when power on1: Terminal command valid when power on
S1 Terminal Function Selection
S2 Terminal Function Selection
S3 Terminal Function SelectionS4 Terminal Function SelectionS5 Terminal Function SelectionS6 Terminal Function Selection
0: No Function 1: Forward2: Reverse3: three-wire control4: Forward Jogging5: Reverse Jogging6: Free run stop 7: Failure reset8: External fault input9: Frequency setting(UP)10:Frequency setting(DOWN)11:Frequency up/down setting clear12:Multi-Speed Terminal 113:Multi-Speed Terminal 214:Multi-Speed Terminal 328:JOG
(Maximum frequency)
-8-
Multi-Speed 7
Multi-Speed 1
Multi-Speed 5
Multi-Speed 4Multi-Speed 3Multi-Speed 2
Multi-Speed 6
Multi-Speed 0
VI lower limit corresponding setting
VI lower limit
VI upper limit
VI upper limit corresponding setting
VI input filtering time
CI lower limit
CI lower limit corresponding setting
CI upper limit
CI upper limit corresponding setting
CI input filtering time
Mo1 output selection
Mo 2 output selection
Relay output selection
0: No output 1: Frequency reached2: FDT output3: Fault opened output4: Motor running forward5: Motor running reverse6: Null speed operating7: Upper limit frequency reached8: Lower limit frequency reached18:R22:Fault normally-closed output
normally-
unning
FM output selectionAnalog
0: Setting frequency1: Running frequency2: Output current3: Output voltage4: Running speed
AO Lower limit
Lower limit corresponding AO output
AO Upper limit
Upper limit corresponding AO output
Motor Overload Protection Option0:No protection
1:normal motor
2:Variable Frequency motor
Motor Overload Protection Current
Power-down Frequency Drop Point
(motor rated current)
(standard bus voltage)
Protection Parameters
Function Code Name Default ValueSetting Range
Advanced function
User password
-9-
Instant power-down Frequency drop rate
Over-vol tage Stall Protection0:prohibit
1:allow
Over-vol tage Stall Protection Voltage
Auto limit current level
Limit current frequency drop rate
Accumulative operating time
The fault before previousfault type
Previous fault type
Current fault type
Operating frequency at current fault
Output amperage at current faul t
Bus voltage at current fault
0:No fault4:Acceleration over-current(E004)5:Deceleration over-current(E005)6:Constant speed over-current(E006)7:Acceleration over-voltage(E002)8:Deceleration over-voltage(E00A)9:Constant speed over-voltage(E003)
10:Bus under-voltage fault(E001)11:Motor overload(E007)12:Inverter overload(E008)14:Output side phase failure(E013)15:Diode module overheat fault(E00E)17:External fault(E00D)19:Current detect error(E015)
Name Setting Range Default ValueFunction Code
App endix A:Dimens ions
-10-
Type 1:Plastic Frame
4 aperture diameter d
Dimension form:
Model AC Drives Model
ApplicableMotor(KW)
Dimensions(mm)
3.The Apparatus Siz e of the Digi tal Hand-Held Programming Panel
Display Panel.....(B58) Mounting Hole Size......(B58)
d
5
5