proe setting and common practice

18
Title: ProE Setting and Common Practice

Upload: aw-ks

Post on 26-Mar-2015

509 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: ProE Setting and Common Practice

Title: ProE Setting and Common Practice

Page 2: ProE Setting and Common Practice

Objective:

This document contains the OC common ProE setting. This is to enable the CAD be efficiently review/reused.

For:All OC ProE user

Instruction:

Sentences in bold red are compulsory requirements for all projects, unless approved by the project supervisor.

ProE Setting and Common Practice

Page 3: ProE Setting and Common Practice

The ProE folder

ProE Setting and Common Practice

Storing external Data like ID master, PCBA, Mechanism etc

Storing Drawing format, symbols, note etc

Storing old ProE files that no longer in use, before permanently delete. This folder is not in the search path

ProE setting file

Screen customization file

File purging. One copy is in the PART, ASSEMBLY and DRAWING folder

Image file for texture

Page 4: ProE Setting and Common Practice

The ProE/FORMAT folder

ProE Setting and Common Practice

Storing Drawing format, symbols, note etc

The Colour and Appearance templete

Default Part and Assembly template

Part and Assembly template for OSD project. The config.pro need to change accordingly

Drawing setting file

Model tree setting file

Page 5: ProE Setting and Common Practice

The ProE UI

ProE Setting and Common Practice

Screen changing mapkey Analysis tool bar

Datum tool bar

Feature tool bar

Filter

Model tree (orca-tree.cfg

setting)

Full object path

Page 6: ProE Setting and Common Practice

The Default part and OSD project part

ProE Setting and Common Practice

The Default part1. Relative accuracy (default 0.012)2. The default orientation as below:

The OSD project part1. Absolute accuracy (1e-4)2. The default orientation as below:

Changing accuracy will cause feature fail. The default part and assembly template need to set correctly from the start.

Page 7: ProE Setting and Common Practice

Top Down Design

ProE Setting and Common Practice

XXXX_id_master

XXXX_layout

merge

merge

XXXX_case_top

For complex assembly, use id master and layout to merge to the case part. The layout file should have important datum like the datum plane “PCB”, which will be the bottom surface of the PCB.

For simple assembly without mechanism, the feature in layout can be build in id master, and part only need to merge the id master.

The id master and layout should have specific layer control. Unnecessary layer should be avoided because all layer will be inherited by the part and crowd the layer window.

Page 8: ProE Setting and Common Practice

The file structure

ProE Setting and Common Practice

XXXX_main_assy.asmXXXX_PCB.asmXXXX_PCB.prtXXXX_case_top.prtXXXX_case_bottom.prtXXXX_screw_mc_M2x6.prtXXXX_screw_st_M2x6.prtXXXX_bracket_pcb.prtXXXX_printmech.asm

1. The naming scheme is: XXXX_type_function/position2. All internal designed part and assembly must have XXXX in front.3. All external designed assembly must be assembly to a packaged assembly (e.g.

XXXX_printmech). The packaged assembly will then be assembled to XXXX_main_assy by default location.

4. ID master should not be assembled to main assy.5. Do not assemble reference component to the module assembly. E.g. the scanner assembly

should not have printer case part. The referencing should be done in separate assembly file.6. All screw and other fastener need to assembled.

Page 9: ProE Setting and Common Practice

The external CAD

ProE Setting and Common Practice

1. The external CAD should be converted and named properly before assembled into main assy.2. The external CAD should be placed in folder with date code e.g. PROE\EXT\DUPLEXER\0911173. The config.pro should add the search path.4. When there is updated external CAD, it should be named properly and placed into folder with new

date code.5. The config.pro search path should be change accordingly. Make sure that the old search path is

deleted to avoid data mixed up.

Main assy

8021_duplexer. Assembled default to main assy. This file name is permanent

091117_saipan_duplexer. Assembly created to import external data. Assembled default or using TFR

File name created automatically with CAD import. Change name like asm00001 or prt00001 to date code

Page 10: ProE Setting and Common Practice

The PCB

ProE Setting and Common Practice

1. The XXXX_PCB.prt must be bare PCB without component.2. The XXXX_PCB.prt should be created in default position whenever possible3. All component must be assembled relative to the XXXX_PCB.prt4. The component should have curve indicating the pads and holes layout. PCB should cut

holes by refer to the curve at assembly level

Page 11: ProE Setting and Common Practice

Layer

ProE Setting and Common Practice

All curve (important curve can be stored at other layer)

The GDT datum and feature control frame

The curve, datum, quilts and datum TFR from id master. These layer is inherited from id master

All datum (important datum like TRF can be stored at other layer)

The curve, datum, quilts and datum TFR from layout. These layer is inherited from layout

All quilt (important quilt like pivot can be stored at other layer)

Page 12: ProE Setting and Common Practice

The View Manager – x-section

ProE Setting and Common Practice

V0

H0

V0 – xsection across dtm RightV1, V2,… - xsection parallel to dtm RightH0 - xsection across dtm Front/TopH1, H2,… - xsection parallel to dtm F/T

Page 13: ProE Setting and Common Practice

The View Manager – Simp Rep and Style

ProE Setting and Common Practice

Simp Rep:1. Unit – have only the component

in shipping condition2. Case_part – have only case part3. Interference - For global

interference checking

Style:

The name indicate the component that is shown in wireframe

Page 14: ProE Setting and Common Practice

Draft Analysis

Each plastic part should have the following draft analysis saved for regular checking:1. DRAFT_1: 1 degree both side, mold direction2. DRAFT_3: 3 degree both side, mold direction3. DRAFT_S1: 1 degree both side, slider/lifter direction

ProE Setting and Common Practice

Analysis name

Select “SolidGeom”

Select “both side”

Page 15: ProE Setting and Common Practice

Modeling Best Practice

ProE Setting and Common Practice

1. Do not create relation in the assembly. Part must only refer to id master and layout. Exception is PCB which refer to component and case part to create holes and keep out area

2. Do not mirror feature. Mirror of surface is permitted.3. Do not use “hole”, “rib” and advanced feature like “lip” and “slot”. The normal protrusion is

more flexible and robust.4. Put “draft”, “round” and “chamfer” at the end of the model tree. Do not scatter around.5. If a new datum is needed for sketch plan, it should be created “on the fly”. The sketch also

should be embedded into the feature whenever possible

Page 16: ProE Setting and Common Practice

Modeling Best Practice (sketch)

ProE Setting and Common Practice

1. During sketch plan setup, use “top” or “front” as top.2. Use TFR as reference in most cases.3. Use PCB as reference for PCB related feature.4. Use surface as reference instead of line.5. Dimension the sketch according to the design intend.6. Use minimum dimension and use more relation.7. Do not leave weak dimension in the sketch.8. Do not use dimension with decimal point more then 2 unless necessary.9. Do not use edge for circle. Should take reference of the cylinder surface and create concentric

circle with equal dimension to the reference.10. Use centerline to locate feature unless the side wall is the functional surface. This will enable

the counterpart using the same dimension scheme.

Page 17: ProE Setting and Common Practice

The Config.pro

ProE Setting and Common Practice

No Item Value Remark

1 Search_path .\PART etc .\ refer to working dir.

2 Template_designasm .\FORMAT\ask_for_more.asm

Change to ask_for_more_hp for OSD project

3 Template_solidpart .\FORMAT\ask_for_more.prt Change to ask_for_more_hp for OSD project

4 symbol_instance_palette_file

.\FORMAT\DRAWING_FORMAT\INSTANCES\orca_symbols.drw

Drawing symbol palette

5 mdl_tree_cfg_file .\FORMAT\orca_tree.cfg Model tree setting file

6 pro_colormap_path .\FORMAT Appearance.dmt file location

7 drawing_setup_file .\FORMAT\orca_dtl.dtl Drawing setting file

8 sketcher_starts_in_2d no Not orientate to the sketch plan. Easier to select the correct reference

9 gtol_dim_placement UNDER_VALUE GDT feature control frame location

10 tol_mode nominal

Page 18: ProE Setting and Common Practice

The Config.pro

ProE Setting and Common Practice

No Item Value Remark

11 trail_dir C:\ptc\trails Trails file location. Make sure that the computer has the folder. Delete the file regularly.

12 mapkey wc Instruction to read config.pro from the working dir

13 measure_sig_figures 8 The accuracy of the measure function

14 enable_absolute_accuracy

yes Needed for OSD project

15 allow_old_style_round

no Change to yes if old style round is needed

16 tol_display yes To display tolerance in drawing

17 Display_full_object_path

yes Display the part folder and the version

1 tol_display yes To display tolerance in drawing

2 gtol_datums std_asme Datum display according to ASME

3 projection_type third_angle Change to first_angle for some Europe drawing

The orca_dtl.dtl