a quick tidbit from a 2010 publication that was “dumped” by catherine and her esteemed selection...

28
Working memory and hearing aid benefit: A direct relationship?

Upload: dominick-perkin

Post on 01-Apr-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Working memory and hearing aid benefit: A direct

relationship?

Page 2: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

An example of how a readingspan test might work

Read each sentence out loud and then state—”Yes” or “No”—if the sentence makes sense.

At the end of the five sentences, I will ask you to repeat either the first or the last word of each sentence.

ARE YOU READY?

Page 3: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Go change your car color is red

Page 4: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Most men are going to the

game.

Page 5: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Some flowers die in the fall of the

year.

Page 6: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

That neighbor found business at

pink

Page 7: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Small boats can go under bridges

Page 8: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Okay . . . Name the LAST word of each sentence

REDGAMEYEARPINKBRIDGES

Page 9: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Effects of noise and working memory processing of speech for hearing aid

users Ng et al (2013) IJA, 52:433-441.

Purpose: To evaluate the relationship between the benefits of noise reduction and individual’s working memory.

Design: A sentence-final word identification and recall test was conducted in two noise backgrounds with and without noise reduction as well as in quiet. Working memory capacity was measured using a reading span test.

Page 10: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

General findings of study:

• Noise impaired recall performance.

• For late list items the disruptive effect of the competing speech background was virtually cancelled out by noise reduction for persons with high working memory capacity.

Conclusion: Noise reduction can reduce the adverse effect of noise on memory for speech, but only for persons with good working memory capacity.

Page 11: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Clinical Tips From

This Article? The benefit of different hearing

aid noise reduction features may be impacted by your patient’s working memory.

Research data supporting feature benefit is probably from people with good working memory (participants screened as part of research protocol)

Page 12: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

In general, we’ll talk about four important components of fitting hearing aids:

Pre-fitting considerationsSelection of technologyVerification of the fittingPost-fitting follow-up and

counseling

Page 13: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

A quick mention of an article that indirectly relates to verification:

Getting to know the ISTS

Page 14: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Development and analysis of an International Speech

Test Signal (ISTS)

Holube I, Fredelake S, Vlaming M, Kollmeier B.

Int J Audiol. 2010 Dec;49(12)

Page 15: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

A couple of abbreviations to know:

The ISTS was developed as part of the ISMADHA project for the EHIMA.

ISMADHA=International Standards for Measuring Advanced Digital Hearing Aids

EHIMA= European Hearing Instrument Manufacturer’s Association.

Page 16: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

About the ISTS:

The signal consists of concatenated speech of six female speakers; six different languages.

The result is a non-intelligible real-speech signal that has all the most relevant properties of natural speech, yet it is not linked to a specific language.

A review of ISTS you might like: http://www.audiology.org/Documents/AN2009Handouts/LM613_Fortune.pdf

Page 17: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Clinical Tip From

This Article?

There is a pretty good chance that you are going to be hearing about the ISTS more as years go by.

The signal was well researched, and is an effective signal for your routine use (some manufacturers are using it already)

Page 18: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

The importance of audibility in successful amplification of hearing loss

Ron Leavitt and Carol FlexerHearing Review, December, 2012

Page 19: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

What they did . . .

Selected the premier product from each of the “Big Six,” and programmed these hearing aids to each manufacturer's recommended fitting. All special features were activated.

For benchmarking purposes, they added a 7th hearing aid—a circa 2002 single-channel analog instrument, which they programmed to NAL-NL1.

Page 20: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

What they did . . .

The subjects were all experienced hearing aid users with typical downward sloping hearing losses.

The subjects, fitted bilaterally, were tested with all seven sets of instruments. The speech recognition test was the QuickSIN, presented at 57 dB SPL.

Following the initial testing, all hearing aids were re-programmed to NAL-NL1 and QuickSIN testing was repeated

Page 21: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Series1

-18

-16

-14

-12

-10

-8

-6

-4

-2

0

Manufacturer's Fit Fitted To NAL-NL1

HA-1 HA-2 HA-3 HA-4 HA-5 HA-6 OLD

Performance for the aided QuickSIN presented soundfield at 57 dB SPL. Bars indicate “SNR-Loss”: The average SNR

disadvantage compared to individuals with normal hearing

Page 22: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Clinical Tip From

This Article?

If you want to help your patients understand speech in background noise, it is very risky to use the manufacturer’s proprietary fitting.

Page 23: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

The Accuracy of Matching Target Insertion Gains with

Open-Fit Hearing Aids

Aazh, H., Moore, B., Prasher, D.

American Journal of Audiology,2012, 21, 175-180

Page 24: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

What they did . . .

30 people; 51 ears All open fittings NAL-NL1 selected in

fitting software

Page 25: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

What they found . . .

71% of fittings had a >10 dB mismatch from target at one or more frequency through 4000 Hz.

After adjustment, 82% met target (majority could be met through 2000 Hz)

Page 26: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

Clinical Tip From

These Articles?

If you believe that fitting to prescriptive target is a good thing, it is very risky to use the manufacturer’s fitting algorithm without real-ear verification.

Page 27: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

REMEMBER THESE

ADS FOR VERIFIT?

Page 28: A quick tidbit from a 2010 publication that was “dumped” by Catherine and her esteemed selection committee

That’s a bummer of a birthmark,

Hal!

While targets aren’t so good for Hal, what about hearing aid

fittings?