9 Simatic s5 Catalog St50 En

Download 9 Simatic s5 Catalog St50 En

Post on 07-Nov-2014

212 views

Category:

Documents

14 download

Embed Size (px)

DESCRIPTION

S5 manual

TRANSCRIPT

Introduction

SIMATIC is a family of pro grammable controllers (PLCs) consisting of many finely tuned components: Program mable controllers, program ming devices, intelligent in put/output modules, etc. And each product group encom passes in turn a whole range of individual components. Programmable controllers From the compact mini con troller to the highperfor mance PLC. There are SIMATIC controllers for every demand and every require ment, in all types and sizes. What they all have in common is high processing capability packed into the smallest pos sible space, ruggedness to cope with the harshest me chanical and climatic require ments, high speed and ex pandability.

There are HMI systems and systems for open communica tions to match SIMATIC. This graded performance capability is the strength of the SIMATIC family.

This catalog gives you in formation on our product ranges SIMATIC S5, SIMATIC 505, SIMATIC programming devices, SIMATIC PCs and SIMATIC S5 software.

Redundant systems Failsafety? High availability? No problem for SIMATIC S5/505! We offer the following PLCs based on our S595U, S5115U, S5155U and 505 standard systems S The S595F and the S5115F, two failsafe PLCs which can be used wherever there could be danger to person nel, material or the environ ment.

S

The S5115H, S5155H and TI505 systems, three fault tolerant systems which can be used wherever produc tion downtimes must be avoided at all costs.

E

Siemens AG 1998

Siemens ST 50 1998

Introduction

Programmable controllers (continued)

Intelligent I/O modules SIMATIC S5/TI505 PLCs don't just perform openloop control these days, they also handle the following: S Closedloop control S Positioning S Counting, proportioning S Valve control and much more. For this purpose, there are in telligent I/O modules: They are microprocessor con trolled and execute timecriti cal special tasks completely autonomously, and they have a direct connection to the pro cess via their own input/out put channels. This avoids additional loads for the CPU.

Distributed I/Os If it is necessary to bridge large distances between the process and the I/O modules, the wiring can become very complex and susceptible to faults. If a modular and flex ible automation system is re quired, we recommend use of distributed I/O systems: S Using the ET 100U elec tronic terminator, I/O mod ules can be located up to 3 km/1.8 miles from the pro cess.

S

With the ET 200 distributed I/O system, you can use dis tributed I/Os, minicontrol lers and a large number of field devices at distances of up to 23 km/14.3 miles from the programmable controller. The connected devices are networked over the PROFIBUSDP highspeed fieldbus, complying with EN 50 170.

Programming devices, software

The SIMATIC family offers you an attractive overall program ming devices, concept - from the lowcost handheld pro gramming devices to the es pecially powerful desktop programming devices. The rugged industrial PCs of the SIMATIC range are the ideal tools for acquiring, pro cessing and archiving ma chine data and process data

And to match these - our soft ware. Starting with the operat ing system: S WINDOWS 95 for the proven SIMATIC software and for all PC applications for operator control and visu alization of material flows and manufacturing sequences, as well as for process control tasks.

And our STEP 5/TISOFT soft ware allows you to program your controller simply and quickly. You generate, docu ment and test with one and the same software.

Industrial PC

The PCSR software for monitoring, openloop control and closedloop control is available specially for high speed configuring of lowend and mid range process con trol systems.

HMI

The more complex automated processes become, the more important it is to have man machine communications" suited to the process. The productivity of any manufacturing system de pends to a great extent on the flexibility of the control sys tems used. Decentralization means increased flexibility but also an increased need for devices to exchange data with each other and with a host computer. Services such as qualified consultation, dependable maintenance or training all help you to realize the full po tential of your SIMATIC.

Our range of SIMATIC HMI devices provides the right solution for every task.

Open communications

SIMATIC offers a choice of two solutions for this purpose: S Pointtopoint connection from CPU to CPU or over communications processors where only a few nodes are to be linked

S

Communications over the In dustrial Ethernet, PROFIBUS or SINEC L1 local area net works where larger numbers of programmable controllers are to be linked.

Services

Siemens ST 50 1998

1/3

Introduction

SIMATIC S5-90U

The mini PLC at a mini price. The cost effective alternative for more simple requirements.

SIMATIC S5-95U

The highspeed mini PLC with compact performance power in a small space.

SIMATIC S5-90U Main memory for program and data (1 statement = 2 bytes) Execution time for 1 K binary statements Flags Counters Timers Arithmetic functions Digital inputs/outputs, maximum/of which onboard Analog inputs/outputs, maximum/of which onboard HMI devices Communications: Pointtopoint connection Bustype LANs 4 KB RAM/EPROM/EEPROM 2 ms 1024, of which 512 retentive 32, of which 8 retentive 32 +, 176/16 16/0 J J SINEC L1 (slave) AS-Interface PROFIBUS (with CP 541) PROFIBUSDP slave (with CP 541)

SIMATIC S5-95U 16 KB plus 4 KB for data1) RAM/EPROM/EEPROM 2 ms 2048, of which 512 retentive 128, of which 8 retentive 32 +, -, x, : 480/32 41/9 J J (2nd serial interface optional) SINEC L1 (slave) PROFIBUS (optional) PROFIBUSDP slave (optional) PROFIBUSDP master (optional)

J = can be connected/available = cannot be connected/not available 1) Not with basic version, PROFIBUS master interface

1/4

Siemens ST 50 1998

Introduction

SIMATIC S5-100U

The modular mini PLC which saves space with extradis crete modular expandability.

SIMATIC S5-100U with CPU 100 2 KB RAM/EPROM/EEPROM 70 ms 1024, of which 512 retentive 16, of which 8 retentive 16 +, 256/0 8/0 J J

CPU 102 4 KB RAM/EPROM/EEPROM 7 ms 1024, of which 512 retentive 32, of which 8 retentive 32 +, -, x, : 448/0 16/0 J J SINEC L1 (slave) AS-Interface PROFIBUS (with CP 541) PROFIBUSDP slave (with CP 541)

CPU 103 20 KB RAM/EPROM/EEPROM 0.8 ms 2048, of which 512 retentive 128, of which 8 retentive 128 +, -, x, : 448/0 32/0 J J SINEC L1 (slave) AS-Interface PROFIBUS (with CP 541) PROFIBUSDP slave (with CP 541)

Siemens ST 50 1998

1/5

Introduction

SIMATIC S5-115U

The rugged programmable controller without fan for the entire midrange. It can be adapted in stages exactly to your requirements.

CPU 941 Main memory for program and data (1 statement = 2 bytes) Execution time for 1 K binary statements Flags/S flags Counters Timers Arithmetic functions Digital inputs/outputs, max. 18 KB RAM/EPROM/ EEPROM 1.6 ms 2048/01) 1281) 1281) +, -, x, :2) 4096/4096 of which max. 512 with process I/O image 256/256

CPU 942 42 KB RAM/EPROM/ EEPROM 1.6 ms 2048/01) 1281) 1281) +, -, x, :2) 4096/4096 of which 1024/1024 with process I/O image 256/256

CPU 943 48 KB RAM/EPROM/ EEPROM 0.8 ms 2048/01) 1281) 1281) +, -, x, :2) 4096/4096 of which 1024/1024 with process I/O image 256/256

CPU 944 96 KB RAM/EPROM/ EEPROM 0.8 ms 2048/01) 1281) 1281) +, -, x, :2) 4096/4096 of which 1024/1024 with process I/O image 256/256

CPU 945 256/384 KB RAM/EPROM/ EEPROM 0.1 ms 2048/327681) 2561)2561)

+, -, x, :3) 4096/4096 of which 1024/1024 with process I/O image 256/256

Analog inputs/outputs, max.

HMI devices Communications: Pointtopoint connection Bustype LANs

J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J

SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J = can be connected/available 1) Of which all, half or none can be retentive = cannot be connected/not available 2) Fixed point

1/6

Siemens ST 50 1998

Introduction

SIMATIC S5-135U SIMATIC S5-155U

S5-135U The compact controller with multiprocessor capacity for all tasks of the midrange. It saves a lot of space in the control cabinet with its com pact modules.

S5-155U The highperformance PLC which combines the highest performance levels with ex tremely short execution times - the memory giant with mul tiprocessor capability".

CPU 922 64 KB RAM/EPROM and 22 KB RAM for data blocks 20 ms 2048/0 128 128 +, -, x, :3)

CPU 928 64 KB RAM/EPROM and 46 KB RAM for data blocks 1.1 ms 2048/0 256 256 +, -, x, :3)

CPU 928B 64 KB RAM/EPROM and 46 KB RAM for data blocks 0.6 ms 2048/8192 256 256 +, -, x, :3)

CPU 9484) 640/1664 KB RAM/FlashEPROM 0.2 ms 2048/32768 256 256 +, -, x, :3)

max. 1024/1024 with process I/O image in addition 3072/3072 without process I/O image in addition 4096/4096 with direct memory access in addition 518152/518152 with page addressing max. 192/192 in addition 256/256 with direct memory access in addition 32130/32130 with page addressing J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface 3) Fixed point/floating point 4) For S5155U onlySiemens ST 50 1998

J SINEC L1 PROFIBUS Ind. Ethernet AS-Interface

J J SINEC L1 (slave) PROFIBUS Ind. Ethernet AS-Interface

J J SINEC L1 (slave) PROFIBUS Ind. Ethernet AS-Interface

1/7

Introduction

SIMATIC 505

The powerful programm

Recommended