1a - p l c - allen bradley
TRANSCRIPT
-
8/11/2019 1A - P L C - Allen Bradley
1/45
Prolific Systems and Technologies Pvt Ltd
Programmable Logic ControllersAllen Bradley
2005
-
8/11/2019 1A - P L C - Allen Bradley
2/45
PLC Ranges Available
PICOMircoLogixSLCPLCCompact Logix
Flex LogixControl Logix
-
8/11/2019 1A - P L C - Allen Bradley
3/45
-
8/11/2019 1A - P L C - Allen Bradley
4/45
Allen Bradley : Micrologix
-
8/11/2019 1A - P L C - Allen Bradley
5/45
Allen Bradley : SLC
-
8/11/2019 1A - P L C - Allen Bradley
6/45
Allen Bradley : PLC
-
8/11/2019 1A - P L C - Allen Bradley
7/45
Allen Bradley : CompactLogix
-
8/11/2019 1A - P L C - Allen Bradley
8/45
Allen Bradley : FlexLogix
-
8/11/2019 1A - P L C - Allen Bradley
9/45
Allen Bradley : ControlLogix
-
8/11/2019 1A - P L C - Allen Bradley
10/45
Allen Bradley : SLC system
-
8/11/2019 1A - P L C - Allen Bradley
11/45
ModularityModular processors, power supplies, I/O, memoryoptions, and communication interfaces allow for a configurable andexpandable system. You configure your system for the number of I/O,
the amount of memory, and the communication networks you need.Later, when you want to expand the system, you can add I/O orcommunication interfaces.
Fast delivery of messagesBetween networks, between links within
networks, and between modules across the backplane.
Industrially hardened productDesigned to withstand the vibrations,thermal extremes, and electrical noise associated with harsh industrialenvironments.
Benefits
-
8/11/2019 1A - P L C - Allen Bradley
12/45
Compact designFits in limited panel space.
Many network optionsTake advantage of distributed processing byconnecting processors across Ethernet, ControlNet, DeviceNet, DH+, andDH-485 networks.
More I/O choicesDistributed I/O at locations remote from theprocessor can be connected across ControlNet, DeviceNet, and UniversalRemote I/O links.
Benefits
-
8/11/2019 1A - P L C - Allen Bradley
13/45
System Components
A modular-hardware SLC / 1746 control system at minimum consists of aprocessor module and I/O modules in a single 1746 chassis with a powersupply. The 1746 power supply connects to the left end of each 1746 chassis.You can configure a system with one, two, or three local chassis, for a total of30 local I/O or communication modules maximum. You connect multiplelocal chassis together with chassis interconnect cables to extend thebackplane signal lines from one chassis to another.
Choose the processor module with the on-board communication ports youneed. You optionally add modules to provide additional communication
ports for the processor. For I/O in locations remote from the processor, youmust add an I/O scanner module for ControlNet, DeviceNet, or UniversalRemote I/O port.
Depending on the communication ports available on your particular SLC
control system, you can select operator interfaces that are compatible withthose particular ports.
-
8/11/2019 1A - P L C - Allen Bradley
14/45
SLC 500 processors are available in a large range of forcible I/O (4096inputs plus 4096 outputs maximum) and maximum user memory (1Kinstructions through 64K words). Several modular processors are capableof controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely locatedI/O across ControlNet, DeviceNet, and Universal Remote I/O links.
The 1746/1747 platform provides a modular-hardware system formaximum flexibility. SLC 500 processors are single-slot modules that youplace into the left-most slot of a 1746 I/O chassis. For 1746 I/O in a
location remote from the processor, the I/O adapter is a single-slotmodule that you place into the left-most slot of a 1746 I/O chassis.
The 1746 I/O chassis are built for back-panel mounting. The 1746 I/Ochassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/O
modules are available in densities of a maximum of 32 I/O per module.
Product Design : CPU
-
8/11/2019 1A - P L C - Allen Bradley
15/45
SLC 500 processors are available in a large range of forcible I/O (4096inputs plus 4096 outputs maximum) and maximum user memory (1Kinstructions through 64K words). Several modular processors are capableof controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely locatedI/O across ControlNet, DeviceNet, and Universal Remote I/O links.
The 1746/1747 platform provides a modular-hardware system formaximum flexibility. SLC 500 processors are single-slot modules that youplace into the left-most slot of a 1746 I/O chassis. For 1746 I/O in a
location remote from the processor, the I/O adapter is a single-slotmodule that you place into the left-most slot of a 1746 I/O chassis.
Product Design : CPU
-
8/11/2019 1A - P L C - Allen Bradley
16/45
The 1746 I/O chassis are built for back-panel mounting. The 1746 I/Ochassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/Omodules are available in densities of a maximum of 32 I/O per module.
You can configure a system with one, two, or three local chassis, for atotal of 30 local I/O or communication modules maximum. You connectmultiple local chassis together with chassis interconnect cables to extendthe backplane signal lines from one chassis to another. This same 30-I/O-module limit applies to a chassis remote from the processor with an I/O
adapter module in the first slot.
Product Design : Chassis and I/O modules
-
8/11/2019 1A - P L C - Allen Bradley
17/45
Various models of SLC processors have various on-board ports forcommunication with other processors or computers. Also, separatemodules are available to provide additional communication ports forcommunication with other processors, computers, and remotely locatedI/O.
Each SLC processor has one or two built-in ports for either EtherNet/IP,DH+, DH-485, or RS-232 (DF1, ASCII, OR DH-485 protocol)communication.
I/O adapter modules for 1746 I/O are also available for ControlNet andUniversal Remote I/O links.
Communication
-
8/11/2019 1A - P L C - Allen Bradley
18/45
-
8/11/2019 1A - P L C - Allen Bradley
19/45
-
8/11/2019 1A - P L C - Allen Bradley
20/45
-
8/11/2019 1A - P L C - Allen Bradley
21/45
-
8/11/2019 1A - P L C - Allen Bradley
22/45
-
8/11/2019 1A - P L C - Allen Bradley
23/45
-
8/11/2019 1A - P L C - Allen Bradley
24/45
-
8/11/2019 1A - P L C - Allen Bradley
25/45
CPU Specifications
-
8/11/2019 1A - P L C - Allen Bradley
26/45
CPU Selection
-
8/11/2019 1A - P L C - Allen Bradley
27/45
Various Processor Available
-
8/11/2019 1A - P L C - Allen Bradley
28/45
Various Processor Available
-
8/11/2019 1A - P L C - Allen Bradley
29/45
Memory Devices
-
8/11/2019 1A - P L C - Allen Bradley
30/45
Analog I/P modules
1746 Analog module do not require external power
-
8/11/2019 1A - P L C - Allen Bradley
31/45
Analog O/P modules
-
8/11/2019 1A - P L C - Allen Bradley
32/45
Analog I/O combination modules
-
8/11/2019 1A - P L C - Allen Bradley
33/45
RTD modules
-
8/11/2019 1A - P L C - Allen Bradley
34/45
Thermocouple modules
-
8/11/2019 1A - P L C - Allen Bradley
35/45
Digital AC Input modules
-
8/11/2019 1A - P L C - Allen Bradley
36/45
Digital DC Input modules
-
8/11/2019 1A - P L C - Allen Bradley
37/45
Digital AC Output modules
-
8/11/2019 1A - P L C - Allen Bradley
38/45
Digital DC Output modules
-
8/11/2019 1A - P L C - Allen Bradley
39/45
Digital Contact Output modules
-
8/11/2019 1A - P L C - Allen Bradley
40/45
Digital I/O Combination modules
-
8/11/2019 1A - P L C - Allen Bradley
41/45
Distributed I/O Modules
-
8/11/2019 1A - P L C - Allen Bradley
42/45
Types of wiring
ommun cat on o u es
-
8/11/2019 1A - P L C - Allen Bradley
43/45
Communication Modules
-
8/11/2019 1A - P L C - Allen Bradley
44/45
Communication Modules
PLC Programming Software
-
8/11/2019 1A - P L C - Allen Bradley
45/45
PLC Programming Software