weatherization assistant 827 field implementation issues
DESCRIPTION
Weatherization Assistant 827 Field Implementation Issues. Martha Benewicz WI Division of Energy Services. NEAT & MHEA Umbrella. Weatherization Assistance 827 includes: NEAT: The National Energy Audit Tool MHEA: Mobile Home Energy Audit Most recent version released in September 2006. - PowerPoint PPT PresentationTRANSCRIPT
Weatherization Assistant 827
Field Implementation Issues
Martha BenewiczWI Division of Energy
Services
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
2
NEAT & MHEA Umbrella
Weatherization Assistance 827 includes: NEAT: The National Energy
Audit Tool MHEA: Mobile Home Energy
Audit Most recent version released
in September 2006
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
3
No Free Lunch
Any energy audit will require a substantial commitment by State
National tools require customization Or modeling protocols
developed by state
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
4
NEAT Users Here Minnesota: a customized version
of the audit Time and money to get the product
you want Wisconsin: extensive protocols to
make the audit reflect our program We’d like to customize the audit to
get the product we want
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
5
WI Moved to NEAT 2003
Started with Version 7.4.3 Re-established our priority list,
switching from WECC 4.0 Required use: about 10% of our
units Boiler Replacement Exterior perimeter insulation Atypical buildings
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
6
Problematic Applications
NEAT doesn’t model exterior foundation treatments We had to develop our own calculations
and use the Itemized cost tab. Atypical buildings are also
questionable Example: Someone lives in a silo
Large foundation? One wall? Ratio of wall to attic is pretty weird
Or a storage tank
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
7
And, Really We Shouldn’t Expect It To
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
8
2006 Moved to WX Assistant 8.27
We liked the: Administrative features
Could develop a work order using measures list or the audit
The inventory tracking looked promising
Expected to customize the audit to our reporting system
GIS mapping and photo feature
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
9
We Really Liked
Improved lay-out and versatility Model two efficiencies of heating
systems Attic insulation level
Expanded Itemized cost section Allows management of alternative
measures by including in the building’s SIR
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
10
We had decided to move to MHEA for mobile home weatherization Looked like it would a DOE
requirement Implementation with the most
recent version Did not expect to be the first
state using the this version
MHEA
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
11
A Talking Audit
We expected to link the audit with our reporting system Minnesota worked with ORNL to do that
ORNL has been busy updating audit We are waiting for the upgrade We believe the cost-benefit of having
the measures ordered reconciled to actual, expensed, and reported to be BIG
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
12
Implementation Issues
Energy Auditor expertise & experience 10% not enough to know and
work well with the tool Most auditors with previous
computer audit experience had moved up
Starting from scratch
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
13
More Implementation Issues
10% of jobs was not enough for the state to make a big commitment % of one staff persons time % of a sub-contractor’s time
Training for all auditors once or twice a year
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
14
Priority Lists vs. Energy Audit
WI’s Current status: MHEA Audit used on all
mobile homes. NEAT used on >40% of jobs:
Boiler replacement Exterior perimeter insulation Repair costs>$500 Health & Safety costs >$1,000
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
15
Running More Audits
Using the audit more frequently Better performance in the field
New understanding for Energy Auditors Savings-to-Investment Ratio
Concept Beginning to see the relationship
between health & safety and repair costs and SIR
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
16
Validating Measures
Use NEAT to review and validate measures about once a year.
Universe of 80 jobs that reflect our housing stock and fuel use Re-run with current audit version Updated libraries and parameters
Costs and fuel use
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
17
Things Change
Changes in five year period: Fuel costs:
2003 2007Oil: $.90 $2.37LP: $.83 $1.76NG: $8.12 $11.2EL: $.075 $.108
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
18
2006 Analysis with NEAT
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
19
2006 Analysis with NEAT
Net Present Value: NPV is the discounted total dollar value of lifetime energy savings minus the installation cost (as opposed to SIR, which is the discounted total dollar value of lifetime energy savings divided by the installation cost). Future savings are discounted to account for the time value of money.
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
20
Contributions to Aggregate Net Present
Value
29%
17%
10%
4%6%
34%
Attic insulation
Htg. system replacementWall insulation
Air SealingRefrigerator replacement
Other
NPV is the discounted total dollar value of lifetime energy savings minus the installation cost.
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
21
Manageable Change
Weatherization Assistant 8: Easy back-up of your database Easy importation and linking to
a new database Older jobs can be re-run with
the click of a button and the jobs are updated to new costs
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
22
Easy to Monitor and Review
Easy to submit one audit—or all audits via e-mail Once your auditors are trained
Allows state or consultant to review the audits Quickly target problems for
training and technical assistance Or corrective action
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
23
We have a wish list of improvements we’d like to see Hopefully we’ll see some of them in the new
release A new version of the Weatherization
Assistant is pending Major issue: Vista compatibility.
Improvements Needed:
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
24
Allow administrating agency to lock the database: Enabled/disabling measures, parameters,
and costs cannot be locked Local users now can disable or enable
measures or otherwise change the set-up information
Lockable Database
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
25
Fuel Switching
Set-up the heating system page to allow for fuel switching
Save a lot of time and reduce the potential for error WI protocol for transposing the
preliminary audit results to a stand alone calculator to determine an SIR
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
26
Foundation Modeling
Include a fail safe warning: Do not allow buildings to be
modeled without foundations The current screen is confusing
to auditors Can’t tell what measures they are
modeling when they enter the data
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
27
Issues for Small Multis
Refrigerators: Only allows one refrigerator to be
modeled Heating Systems
Evaluate only one one primary heating system
Buildings with multiple systems require finesse.
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
28
MHEA Algorithms
Distribution sealing appears to routinely overestimate air sealing SIR. At least warning notices when
the data entered generates huge SIRs
Such as 50.0 or 89.5
2007 DOE National Training Conference Orlando, Florida December 9-12, 2007
29
Implementing an Energy Audit
Don’t underestimate time and resources required to implement We now incorporate on-line and
on-site training and technical assistance
Realize that any “national” tool will need to be managed for your state or agency