Thermal test(lab modules)

G. Riddone, A. SamoshkinLast update 25-Jul-2011

Complement to the presentation on 14.06.2011

Page 2: Thermal test (lab modules)

Thermal tests

• Investigation of the thermo-mechanical behaviour of the module following:– Variation of the ambient temperature– Variation of the RF structure temperature

(PETS and accelerating structures)– Variation of the DB Quadrupole

temperature• Validation of the FEA model by

comparing results with simulated values

2

Page 3: Thermal test (lab modules)

Measurements

• Measurement of temperatures and comparison to simulations BE-RF

• Measurement of deformations/stresses and comparison to simulation EN-MME (K. Artoos) + BE-RF

• Measurement of the RF structure alignment Method to be defined by SU

3

Page 4: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

4

Module Type 0 cooling scheme

Page 5: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

5

Power dissipation by T0 Lab Module components

DB Q DB Q

410 W410 W 410 W 410 W 410 W410 W 410 W 410 W

110 W110 W 110 W110 W

150 W 150 W

PETS 440 WDB Q 300 WAS 3280 W

* Technical Specification for the CLIC Two-Beam ModuleG. RIDDONE EDMS 1097388

*

Page 6: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

6

Heaters for T0 Test Module

max 480 W max 480 W

1600 W 1600 W

Max 3050 W

- One 80” (2024 mm) long heater for DB (PETS)- One 80” (2024 mm) long heater for MB (AS)

- Sixteen 200W cartridges for DB (Quads)

Page 7: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

7

3D Integration layout

Page 8: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

8

Measurements equipment configuration

7 x NI9217 (4xPT100) › 28 temperature

input channels

1 x NI9422 (8xDO) › up to 8 channels for

PWM heaters control

NI Compact DAQ (8 slots) + LabView software

PT

100

PT

10

0

UP

TO

28

PT

10

0 (4

-wir

e re

sist

an

ece

me

asu

rem

en

ts)

3x O

UT

PU

T S

TA

GE

(P

WM

H

EA

TE

R C

ON

TR

OL

– s

olid

st

ate

re

lay

ba

sed

)

Reference -precision thermometer for PT100

calibration

Prepared by M. Sosin

Page 9: Thermal test (lab modules)

JINRAlexandre.Samochkine @ cern.ch

9BE/ABP Survey equipment will be borrowed

Thermometers calibration

Reference thermometer

- Accuracy: 0.02°C- Resolution: 0.001°C

Calibrated PT100's

Reference probe

Solid-heavy copper block with heater

DAQ System

POLYNOMIALS FOR CALIBRATED PT100

- Calibration during slow cooling of heated copper block with all PT100

- Polynomials calculation based on precision reference thermometer

Prepared by M. Sosin

Page 10: Thermal test (lab modules)

Sequence of the tests

10

Possibility to use IR camera to be investigated

Page 11: Thermal test (lab modules)

Planning

• Accelerating structure and PETS being assembled several steps and learning process

• QDB and BPM are available• The aim is to complete the assembly

of the first module by end of 2011– Afterwards thermal tests can start

11