R LED T8 Tube with Aluminium Heat Sink DLC 4.0 E484385 E484385 Lighting Specialists in High Efficiency Lighting

Upload: seniorled

Post on 11-Apr-2017

53 views

Category:

Devices & Hardware


0 download

TRANSCRIPT

Page 1: T8 LED Tubes with Heat Sink - Buyer Guide China

R

LED T8 Tube with

Aluminium Heat Sink

DLC4.0

E484385E484385

Lighting

Specialistsin High

Efficiency

Lighting

Page 2: T8 LED Tubes with Heat Sink - Buyer Guide China

Specialists in High Efficiency Lighting

www.seniorled.com

Polycarbonate(PC) Tube with Internal Aluminium Heat SinkTransparent or frosted fully polycarbonate tube cover for increased light transmission and protection from electrical shock. Perfect for USA where internal isolators are not required by law.

PLUS internal aluminium heat sink for improved heat dissipation and extended lifespan. 270° beam angle for improved light coverage -widest available on the market in 2016! Perfect combination of safety and durability. Light weight and impact resistant for peace of mind during transport and installation.

High Luminous Efficiency 150-165lm/W with CSA Test Report

Low level factories believe increasing the efficiency of LED chips is the only way to increase the light's lumens. We create cost-effective (< $10) high lumen lighting by controlling four aspects:

1.The efficiency of driver must be over 92%.2.Light transmittance diffusion of diffuse cover must be over 93%.3.Maximize every single LED chips output.4.Design the arrangement of IF and VF of LED chips perfectly.

Super DriverWe use Japanese RUBYCON IC and special thickness PCB board for our own perfectly designed driver; producing reliable drivers with a long lifespan.

• Full protection function against short circuiting, current overload, voltage overload and protection against surges. Wide input voltage range. 100-277V. (Maximum industrial input voltage can be customized to 305V if required) Electrolytic capacitor information: DC36-80V 240MA Long lifespan design.(105°C 35000-50000 working hours) THD < 15%

AIG Insured

All of our LED lighting products are insured with AIG Product Liability Insurance. It ensures peace of mind in the rare event of any manufacturing faults or defects by guaranteeing our warranty and compensation.

2

R

Polycarbonate(PC) with Internal Aluminium Heat Sink

Aluminium heat sink

SMLED Chips

Polycarbonate (PC) tube

Page 3: T8 LED Tubes with Heat Sink - Buyer Guide China

www.seniorled.com

FeaturesSingle end power supply (ballast bypass), gives added anti-electric shock measures ensuring safety.Internal constant current driver features a instant start up or shut off mechanism with no warming up times and flickering as well as protection from overpowering, overheating, electrical shorting and overexposed circuitry.Wide input voltage range 120-277V/AC and THD < 15%.Retrofit for direct replacement of T8 linear fluorescent, compatible with G13 socket (R17D, FA8 available).Environmentally friendly and mercury free – eliminating hazardous installation, removal and disposal.Certified by UL, cUL and DLC 4.0 listed.Long lifespan up to 50,000hrs. Based on ideal temperature (25°C) and 10hrs/day operating conditions.Limited warranty 5 years, insured by AIG.

OfficeSupermarketHotelExhibition hall

COMMERCIAL LIGHTING PUBLIC LIGHTING INDUSTRIAL LIGHTING

TunnelMTR station EtcTrain stationBus stationAirport

FactoryWarehouse

Applications

3

R

Specialists in High Efficiency Lighting

Page 4: T8 LED Tubes with Heat Sink - Buyer Guide China

Certificates UL, cUL, DLC

Ballast Compatible No,Single end power supply

Lamp Body Material PC+Aluminium Heat Sink

Lamp Cover Available Frosted, Clear

3000K 4000K 5000K (6500K without DLC)Color Temperature

Epistar/HongliLED Chips Brand

CRI (Ra) ≥80

Dimmable No

THD <15%

Life Span 50,000 + hours

Warranty 5 Years

www.seniorled.com 4

Power Factor ≥0.95

Beam Angle (°) >160°

LED Type SMD 2835

Header G13

LED Chips Qty (pcs) 126

Real Power (W) 12±1

Clear Lens 1850

luminous flux (lm) (150Lm/w)

Frost Lens 1800

Carton Size (mm) 1305*193*240

Dimension (L*W*D) 1200/26/30mm

Qty per CTN(pcs)

30

Model SLPV-4FT-12W

Input (V)

Electric Spec100~277

Specification

R

Specialists in High Efficiency Lighting

Page 5: T8 LED Tubes with Heat Sink - Buyer Guide China

www.seniorled.com

54200

Pcs per40HQ

1200MM

T8 Length

TUBE

Type

1

Single Box

40

Pcs/ctn

12.8

G.W./ctn(kg)

22360

Pcs per20GP

Finished product pile up

Packing

A

C

Product Dimension

B

Model NO. Size A(MM) Size B(MM) Size C(MM)

SLPV-4FT-12W 1200 26 12.7 (G13)

5

R

* Above loading quantity is calculated without pallet.

Specialists in High Efficiency Lighting

Page 6: T8 LED Tubes with Heat Sink - Buyer Guide China

www.seniorled.com

Installation Guide

BEFORE YOU BEGINRead these instructions completely and carefully.

Provided ComponentsThe components have been properly packed to avoid damage during transit. Inspect the components to confirm there is nophysical damage. Do not install damaged components.

The carton consists of: LED tubes Drivers Instruction sheet Labels

Tools and Components RequiredScrewdriver (6-12mm)

Wire cutters

WARNINGRISK OF FIRE OR ELECTRIC SHOCK• Disconnect power before installation or maintenance.

Contact a qualified electrician for installation.

LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

• Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.

• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

CAUTIONRISK OF INJURY• Tube may fall down if not installed properly, follow installation

instructions. • Wear safety glasses and proper aid during installation and maintenance.

RISK OF PRODUCT DAMAGE• Do not replace conventional LFL directly with LED tubes.

Save These Instructions These Instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problem arise which are not coveredsufficiently for the purchaser’s purpose, the matter should bereferred to Seniorled Ltd. Seniorled does not claim liability for any installation not performed according to this guide or not by a qualified electrician.

Installation to be performed by factory trained or qualifiedpersonnel. Ensure this manual is provided to the installers and users.

Use this product only in the manner intended by the

manufacturer. If there are any questions or concerns,

contact the manufacturer.

This tube is designed for indoor application only, and

should not be used in environment of high temperature

and high humidity.

This device is not intended for use with Emergency exits.

Suitable for dry location.

Max. 4pcs LED tubes can be operated in a luminaire.

For Your SafetyRead and observe all CAUTIONS and WARNINGS shown throughout these instructions.

Refit Solutions

6

R

Specialists in High Efficiency Lighting

Page 7: T8 LED Tubes with Heat Sink - Buyer Guide China

www.seniorled.com

Inspire-led Tube

Retrofit

7

Fluorescent Tube

Fluorescent Tube

Remove ballast reconnect the wire

Remove ballast reconnect the wire

PackagingIt is important to inspect and replace the socket/tube holder or remove the brass tab in the socket/tubeholder that may join the Live and natural wires causing a short circuit.

The socket/tube holder must separate the live wire connection from the natural wire.

If the ballast contains PCB please remove and dispose of them safely. They are extremely toxic andhazardous to people and the environment.

Take out the ballast and starter if found (disconnect the wires and either leave the ballast in place or remove it). After disconnecting the ballast, reconnect the circuit. There are two sets of wires that connect to each bulb - only one set is needed to be connected to the respective Live and natural wires.Refer to the wiring diagram. If you have a fixture with more than one tube holder (double or quads), make sure only one wire set from each additional fixture is going to the Live and natural supply wires.Disconnect any jumper wires connecting the additional fixtures to each other. In effect, on a single tube there should be four wires (two at each end) going to the the live and natural supply wires. Now you only need one going to the live and natural supply wires from each fixture. Refer to the wiring diagram.

Install the new LED Tube into the fluorescent light fixture.

Inspect all wiring connections prior to turning on the power. Switch on the power to light the LED tube.

Installation steps retrofit existing fixture with ballast

Installation based on Magnetic Ballast Installation based on Electronic Ballast

Senior Led Tube

Senior Led Tube

Retrofit

AC100-277V

AC100-277V

Remove the starter,reconnect the wire.

Remove ballastreconnect the wire.

Remove ballastreconnect the wire.

Electronic Ballast

Electronic Ballast

No Electrical Connections.Used only for fixture support.

No Electrical Connections.Used only for fixture support.

R

Specialists in High Efficiency Lighting

Page 8: T8 LED Tubes with Heat Sink - Buyer Guide China

www.seniorled.com

New Installation – fixture without ballastThere are two sets of wires that connect to each bulb –only one set is needed to be connected to the respective Live and natural wires.If you have a fixture with more than one tube holder (double or quads), make sure that only one wire set from each additional fixture is going to the Live and cold supply wires. Disconnect any jumper wire connecting the additional fixtures to each other. In effect, on a single tube there were four wires (two at each end) going to the Live and natural supply wires. Now you only need one going to the Live and natural from each fixture.Install the new Internal Driver LED tube into the fluorescent light fixture.Inspect all wiring connections prior to turning on the power.Switch on the power to light the LED tube.

8

AC100-277V

Switch

No Electrical Connections.Used only for fixture support.

R