Page 1: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

siemens.com/wincc-open-architecture

SIMATIC WinCC Open Architecture

SCADA System

Page 2: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

2

SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree of client-specific adapta-bility, large and/or complex applications and projects that impose specific system requirements and func-tions. SIMATIC WinCC Open Architecture enables handling with bigger amounts of data with even smal-ler hardware solutions.Highlights SIMATIC WinCC Open Architecture:• Objectorientationfacilitatesefficiencyinengineering

andflexiblesystemexpansions• Upto2,048systemsondistributedsystems• Scalableuptonetworkedredundanthigh-endsystems

withmorethan10milliontags• Platform-independentandavailableforWindows,

LinuxandSolaris• HotStandbyRedundancyandDisasterRecovery

Systemguaranteehighestreliabilityandavailability• SIL3certifiedaccordingIEC61508• Platformforcustomizedsolutions• Comprehensiverangeofdriversandconnectivity:

SIMATICS7,S7-1200,S7-1500,XML,OPC,TCP/IP,Modbus,IEC60870-5-101/104,DNP3,IEC61850,IEC61400,Ethernet/IP,S-Bus...

Supported operating systems• Microsoft

– Windows8.1– Windows7SP1– WindowsServer2012R2– WindowsServer2008R2

• Linux– RedHatEnterpriseLinux7– OpenSUSE13.1– CentOS7.0

• OracleSolaris– Solaris11x86(ondemand)

• VMWare– ESXi5.5– ESXi5.5Update1

• iPhone/iPad– iOS6orhigher(forApp)

New in SIMATIC WinCC Open Architecture V3.13 ReportingWeb-basedreportinghasbeenimplementedusingastandardizedSOAP(SimpleObjectAccessProtocol)report-inginterface.Thisallowsreportingtoolsfromthird-partysupplierstobeusedwithoutanyadditionaleffort.Modernandsmartreportingopensupgreaterscopeforflexibilityaswellasimprovedusabilityforusers.ReportingisfurthersimplifiedbytheadditionalprovisionofBIRTtemplatesandpre-definedreportingdata.Internalrestructuringhaspermittedimproveddatamanagement,pavingthewayforfasterprocessingoflargevolumesofdata.Usersben-efitfromhigherperformanceandmorerapidhistoricdataretrieval,makingforfasterreporting.Toallowuser-defineddatatobeexportedfromWinCCOAtoexternaldatabases,aDBloggerhasbeenimplemented,enablingtheusertoindependentlydefineandcontroltheflowofinformationfromSIMATICWinCCOpenArchitec-turetothevariousdatabases(MySQL,RDB,a.s.o.).Thispermitstheclassicalcontrolcentertobeseparatedfromtheinformationplatform.Enhancements in the graphical editorQT5isnowsupported,enablingamodern,sophisticateduserexperiencefortheoperator.Theeditornowalsofeaturesanew3Dbarwidget,anarrayofnewtrendfunc-tionsandatablewidget.

Technical product description SIMATIC WinCC Open Architecture V3.13

Reporting

Page 3: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

3

Enhancements in engineering• The“Wizardframework”providessupportinthegen-

erationofwizardsandapplications,andsocreatesastandardizedlook&feel,alsoforprojectwizards.

• Theterm“flexiblesystemmodel”isusedtodescribethedepictionofsystemdatapointswithdifferent,flexiblehierarchies.Benefits:Greaterflexibility,definitionofmultiplehier-archies,simpleengineeringduetoadedicatededitor,multipleuseofsystemmodelsinprojects

Enhancements for distributed systems• Bycachingdatapointinformation,onlythechanged

datapointsneedtobetransmittedafterreconnect-ingtheUI.Thisresultsinhigherperformanceduetoshorterstartuptimes,areducednetworkloadandfastersynchronization.

• “OneWayDist”isasupplementaryfunctionfordistributedsystemswhichpermitsdataexchangetobedeactivatedinonedirection.Thisreducesloadonthenetworkandresultsinfastersynchronizationindistributedsystems.

Enhancements for VIDEO TheVIDEOoptionpermitsthenativeintegrationofvideomanagementfunctionsandhasbeenextendedtoincludeanumberofimportantfunctionalfeatures.Itisnowpossibleforvideostobedigitallyrecordedonstandardhardwarecomponents.Thevideostreamscanbesavedeithercontinuouslyinaringmemoryorevent-drivenwithadefinedlead-inandlead-outtime.Recordingsfromsev-eralcamerascanbeplayedbacksynchronously.Recordedvideostreamscanbeexportedtogetherwiththerel-evanttimeinformation,whileretainingthevideostreamformatsuppliedbythecamera.Existinganalogequip-mentsuchasanalogcrossbarsandtheircamerascanbeintegrated,wherebyapoolmanagementsystemswitchesthecrossbarinputsandoutputs.IntuitivelyoperateduserinterfacesintheScadasystemcanbeusedtoconfiguresequencessuchasvirtualtours,whichcanthenbeshownataworkstation,onavideowalloronadisplaymonitor.

WinCC OA on the Nanobox PC 227D / 277DSIMATICWinCCOpenArchitectureV3.13runswithfullserverfunctionsontheNanoboxPC227D/277D.DedicatedlicensepackagesareavailablefortheNanoboxPC.Thisisidealforuseasadataloggerincombinationwithdistributedsystems.New driver IEC 61850/61400ConnectionofIEC61850andIEC61400devicesincludingbrowsingtheentiresystem.Enhancements for the WinCC OA OPERATORThedesignhasbeencompletelyrevisedandfullyadaptedinlinewithiOS7.AdedicatediPadversionwithanad-ditionalalarmlineonthehomescreenprovidesoptimumoperatingconvenienceatthetablet.Tomakeforanevenbetteruserexperience,anumberofsupplementaryfunctionshavebeenimplemented.Thedetailedvaluescreenalsoshowstherelevantalarm,whichcanthenbeacknowledgeddirectly.Anotheraddedfeatureisaninte-grateduserlistwhichallowsotheruserstobecontacteddirectlyfromwithintheapp.Theaccustomedmulti-lan-guagecapabilityofWinCCOAhasbeenadopted,enablingthelanguagetobechangedduringrunningoperationandsetforeachindividualproject.Enhancements for the Ultralight ClientTheUltralightClientpermitsplantimagestobedepictedondifferentweb-baseddeviceswithouttheneedforadditionalengineering.Anumberoffeatureshavebeenaddedhere,suchasanoptimizedalarmscreen,improvedtrending,automaticlogoutandautomaticscreenscaling.

WinCCOAOPERATORiniOS7design–alsooptimizedforiPad

Page 4: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

4

Platforms• Windows• Linux• OracleSolaris• IPC227D/277D„Nanobox“Support(32Bit)

Object orientation• Referencingofsymbolsandobjects• Inheritanceofstructureddatapointtypes• Objecthierarchy• Directmappingofdatapointtypestoobjects• Flexibleplantmodel-differentviewsonthedata

modelrealizable

Redundancy• HotStandby• DisasterRecoverySystem(2x2Redundancy)

TheaimofthisfeatureistoextendtheWinCCOAredundancyconceptthroughasecondHotStandbySystem.TheoperabilityofthesystemneverthelessremainsmaintainedonanothersystemevenintheeventofacompletefailureonthefirstHotStandbySystem.Thus,thedatalossandtheidletimearekeptaslowaspossible.

• Automaticclientswitchover• Automaticrecovery• Automaticprocessimageandhistorysynchronization• Automaticsynchronizationofprojectdata• Redundantnetworks(LAN)• Redundantperipheralcomponentsupport

(SIMATICS7)• Splitmodeoperationforupdatesandtesting

Parallel archivingTheparallelHDBandRDBarchivingenablesthestorageofdataintothelocalhistoricaldatabaseandintothecentralOracledatabase.LocalsystemsdonotneedanOracleserverinstallation.ThisarchivingmethodiscompatiblewiththeDisasterRecoverySystem,historicalqueriesandarchivecompressions.

Security• BlockingviaIP-Blacklist• Systemstabilityviaintrinsicsafety• Autonomicsystems• Communication(Standard:SSLencryption,

Option:Secure)• Encryptionofpanels,scriptsandlibraries

SSL encrypted communicationFromversion3.12SSLencryptionforcommunicationofmanagerstoeachotherandtoallclientsisusedconsis-tently.Itisimplementedbydefaultinthesystem.SafetyWinCCOAisSIL3certifiedaccordingtoIEC61508.TUEVSUED(Technicalinspectionagency,SouthGermany)ap-provedthatWinCCOAfunctions,developmentprocessesandsupportingdocumentsareconformtoIECstandard.Aguidelineisprovided,whichdescribesbasicandop-erationalconditionswithinwhichWinCCOAcanbeusedforsafetycriticalprojectsasaprocessvisualizationandcontrolsystem.

Special features of SIMATIC WinCC Open Architecture

Sekundäres Serversystem (SSS)Primäres Serversystem (PSS)

Datenbank in Oracle Cluster

BedienoberflächenFeldgerät oder andere angeschlossene Systeme, wie z.B. OPC UA

WinCC OA Hot Standby

System

WinCC OA Hot Standby

SystemWinCC OA aktiver

Server (A)

WinCC OA passiver Server (B)

WinCC OA aktiver

Server (C)

WinCC OA passiver Server (D)

Datenbank in Oracle Cluster

DisasterRecoverySystem

WinCC OAZentrales System

WinCC OALokales System 1

WinCC OALokales System 2

Oracle DB

RDBManager

RDBManager

HDB HDB

Parallelarchiving

Page 5: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

5

GIS ViewerFullintegrationofstandardizedmapsofcartographicinformation(GIS)withSCADAobjectsinWinCCOA.VideoOfferstheeasypossibilitytointegrateIP-cams,IP-compo-nentswhichfulfilltheONVIF2.0standardandcompletevideomanagementsystemsintoWinCCOA.DuetotheintegrationofSCADAandvideomanagementintoonesystem,theinterfacescanbereducedandthecostsfortraining,maintenanceandoperationarealsoreducedtoaminimum.BACnetBACnetprovidesanintegratedBACnetconformonline-/offline-engineeringsolutionandaspecificobjectlibrary.RecipesRecipemanagementforparametersetsandsetpointlists.Unlimitedrecipetypes,unlimitedrecipequantities,accesscontrol,creationofrecipesfromreal-timeprocessdata.Easy-to-useuserinterface.Import/exportofrecipesasCSV.SchedulerTimerandeventprogramswithsimplegraphicconfigura-tion.Cyclicandacyclic-periodiccall-ups,individualeventsandtimelists,specialdayrules(holidays).Arbitraryactions:valuechanges,recipestarts,reminders,scriptsCommunication CenterProvidesremotealarmsandremoteinformation.AlarmoutputtoSMSande-mail.AMS (Advanced Maintenance Suite)AdvancedMaintenanceSuite(AMS)isaneasilyconfigu-rablesoftwaretoolforefficientplanning,management,realizationandcontrolofreactiveandpreventivemainte-nance.

TrendingTrendwidgetsforintegrationintocustomizedscreensandatrendapplication(Var-Trend)asaready-to-usetrendapplication.Supports:• Onlineandhistoricalvalues• Valuetrendovertimeorvalue• Timecomparisontrends• Bartrends2Dand3D• Displayofinvalidvalues,alarmrangeand/orvalue

range• Multipleorsharedscales,ruler,automaticlegend• Timeresolutioninms,switchduringruntimebetween

localandUTC-time• Zoom/Unzoomoftrendareas

Reporting• Web-basedReportingInterface(SOAP)

– ECLIPSEBIRT– CrystalReports– SIMATICInformationServer– MicrosoftExcel– SeveralReportingtemplatesforECLIPSEBIRT

• Onlinevalues,history• Compresseddata,SQL,alarms• Diagnosticstools• Audittrail

Trend

Page 6: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

6

Architecture• Client-server-system• Functionalseparationintoseveralprocesses

(managers)• Loaddistributiononseveralcomputers• Redundancy(HotStandby)• DisasterRecoverySystem• Multi-server-distributedsystemsupto2048systems• Heterogeneousoperatingsystemsandversion

distribution• Multi-monitoroperation• Multi-loginononeworkstation• Multi-usersystem• Eventorientatedprocess• Internalmessagecompression• Safetyfunctionstoincreasereliability(overload

detectionandregulation,queryrestrictions)

Alarm system• VDI3699/DIN19235• Freelydefinablealarmclasseswith255different

prioritiesanddefinitionofalarmcolors(blinking)• Standard,discreteandmultiinstancealarms• Upto255analogalarmranges• Summaryalarms• Automaticfilteringofalarms(Handlingofalarm

floods)• Panelhierarchysummaryalarms• Combinedalarm-andeventscreen,alarmrow

withdefinablecolumnsetandcolorsandadvancedsortingandfiltering

• Storableconfigurations• Directaccesstotheassociatedprocesswindow• Commentsandattendedvaluesonalarms• Onlinechangeofalarmclasses

Process interfaces / drivers• Eventdrivenorcyclicpolling• Severaldifferentdriversatthesametimeonone

server• Peripherytimestamps• TCP/IP:SIMATICS7,Modbus,Ethernet/IP,

SNMPManager&Agent,BACnet• OPC:OPCClient&Server(DA,A&E),

OPCUAClient&Server(DA,AC)• Telecontrol/RTU:SSI,IEC60870-5-101,-104,

DNP3andSINAUT,IEC61850/61400• AdditionaldriversonrequestorwithaC++API

Data model• Objectorienteddatamodelwithfreelydefinableand

easyconfigurablestructure• Manystandardobjectsincluded• Modelingoftechnologicalobjectsinanyhierarchy• Userdefinabletreestructure• Severaldifferentpropertiesdefinableonelements• Type-in-type(referencing)• Inheritance• Groups• Generatedifferentviewsonthedatamodel

Engineering environment• Graphicaleditor• Projecthierarchyeditor(Paneltopology)• Projecteditor• Databaseeditor• Controlprogrammingeditor,ScriptWizard• MassdataengineeringandASCIIin/outmanager• Integrationofexternalversionmanagementtools

(CVS,SVN,…)• Simplesymbols,EWOs,Stylesheets• Frameworkforengineering-&applicationuserinter-

faces

Product details SIMATIC WinCC Open Architecture

Page 7: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

7

Graphical user interface• Drag&Drop• Flexiblewindowtechnique• Platformneutralapplication• Pictureinpicture• Zooming/Panning• Cluttering/Decluttering• Root-,child-andembeddedpanel• Multi-monitoroperation• Multi-selection• Truecolor/synchronousblinking• Upto8picturelayers• Onlinetooltips(multilingual)• Configurablepaneltopology• GUInavigationobjects• Onlineswitchablemultilanguagesupport• UTF-8formultilanguagesupport• Supportsthewidelyusedgraphicalobjectsandwid-

getsalsowithcomprehensiveanimationcapabilities• Supportofexternalwidgets(e.g.ActiveX)• Layoutmanagement“Responsivedesign“• Multitouch

User access• Fulluseraccesssecurityoptionalwithintegrationinto

WindowsActiveDirectory(SingleSignOn)• Variouspermissionlevels• Commandprotocol(Audittrail)• ConformtoFDA21CFRPart11

Internet/Intranet• Web-Server,Webalarmscreen,diagnosticsand

reporting• Webclientbasedonbrowserplug-intechnology• UltralightclientbasedonJavaScript/XHTML• web-basedThinClient(JavaScript/HTML)• Supportsmainsecurityfunctions(HTTPS,Kerberos

encryption,etc.)• mobileAppWinCCOAOPERATOR(iOS)

ArchivingComprehensivearchivingoptions• Valuearchivesasflat-filestructure(HDB)• ORACLEarchiving• Parallelarchiving(Oracle,HDB)• DBLogger(MSSQL,MySQL,ORACLE)• Datacompression• Correctionvalues• Laboratoryvalues• Web-basedReportingInterface(SOAP)• ReportingtemplatesbasedonECLIPSEBIRT

Object libraries• WinCCOAstandardobjectlibrary• SIMATICS7objectlibraries(Basic/Advanced)• BACnetobjectlibrary

Application programming / Scripting• InterpreterwithC-syntax(“Control”language)

andmultithreadingsupport• LibrariesandDLL´sforcustomizedextensionsof

thescriptinglanguage• Debugger/diagnosticstools• Supportsalotofexternalinterfaces,like:database

access,ADO,COMandXML,XMLParser,XML-RPC-Interface,UART-andTCP-access

• Completeaccesstoattributesofgraphicalobjects• Know-howprotection(Panels/scriptsencryption)

UTF-8 for multi language supportAllUnicodecharacterscanberepresentedinfourbytes.MultitouchFeatureslikezooming,panning,declutteringandsafetwo-handoperationaresupported.

Page 8: SCADA System SIMATIC WinCC Open Architecture · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high

Further information:

www.siemens.com/wincc-open-architecture FindalsoadditionalbrochuresandtechnicaldescriptionsaboutSIMATICWinCCOpenArchitectureonourwebsite.Security information:Siemensprovidesproductsandsolutionswithindustrialsecurityfunctionsthatsupportthesecureoperationofplants,solutions,machines,equipmentand/ornetworks.Theyareimportantcomponentsinaholisticindustrialsecurityconcept.Withthisinmind,Siemens’productsandsolutionsundergocontinuousdevelopment.Siemensrecommendsstronglythatyouregularlycheckforproductupdates.ForthesecureoperationofSiemensproductsandsolu-tions,itisnecessarytotakesuitablepreventiveaction(e.g.cellprotectionconcept)andintegrateeachcompo-nentintoaholistic,state-of-the-artindustrialsecuritycon-cept.Third-partyproductsthatmaybeinuseshouldalsobeconsidered.Formoreinformationaboutindustrialsecurity,visithttp://www.siemens.com/industrialsecurity.Tostayinformedaboutproductupdatesastheyoccur,signupforaproduct-specificnewsletter.Formoreinfor-mation,visithttp://support.automation.siemens.com.

Theinformationcontainedinthisbrochuremerelycontaingeneraldescriptionsorperformancecharacteristics,whichmaynotalwaysbeapplicableinthedescribedformtothespecificapplicationcaseormaychangeduetoproductadvancement.Thedesiredperformancecharac-teristicsshallonlybebindingiftheyareexpresslyspecifieduponcon-tractconclusion.AllproductdesignationsmaybebrandsorproductnamesofSiemensAGorothersub-suppliers,whoseutilizationbythirdpartiesfortheirrightsmayviolatetherightsoftheowner.

ETM professional control GmbH

ASiemensCompany

Marktstrasse3

7000Eisenstadt

Austria

Telephone:+43-2682-741-0

www.etm.at

[email protected]

Subjecttochanges11/14

OrderNo.:6ZB5370-1EG02-0BA0

Dispo26100

BR 1114 0.5 EIS 8 En

PrintedinAustria

©ETMprofessionalcontrolGmbH