Page 1: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

siemens.com/wincc-open-architecture

SIMATIC WinCC Open Architecture

SCADA System

© ETM GmbH 2013

Page 2: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

2

SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree of client-specific adapt-ability, large and/or complex applications and projects that impose specific system requirements and func-tions. SIMATIC WinCC Open Architecture enables handling with bigger amounts of data with even smaller hardware solutions.Highlights SIMATIC WinCC Open Architecture:• Objectorientationfacilitatesefficiencyinengineering

andflexiblesystemexpansions• Upto2,048systemsondistributedsystems• Scalableuptonetworkedredundanthigh-endsystems

withmorethan10milliontags• Platform-independentandavailableforWindows,

LinuxandSolaris• HotStandbyRedundancyandDisasterRecovery

Systemguaranteehighestreliabilityandavailability• SIL3certifiedaccordingIEC61508• Platformforcustomizedsolutions• Comprehensiverangeofdriversandconnectivity:

SIMATICS7,XML,OPC,TCP/IP,Modbus,IEC60870-5-101/104,DNP3,IEC61850,Ethernet/IP,S-Bus...

New in SIMATIC WinCC Open Architecture V3.12 SIMATIC WinCC OA OPERATOR EnablesoperationandvisualizationofaWinCCOAinstal-lationviaiPhoneandiPad.Theprocessdata,availabilityandstatusofyoursystemcanbedisplayed.Thelocationfilteringprovidesaquickoverviewofgeographicallydis-tributedsystems,includingsumalerts.Operatingperson-nelhave24/7onlineaccesstothesystemandcanreactinstantlythankstoanimmediatealertfunction.Thissavesprecioustimeandultimatelyenhancessystemavailability.Toconfigurethecontentsoftheappquicklyandeasily,anintuitivewizardhasbeendeveloped.VideoThevideofeaturehasbeencompletelyrevised,andoffersnowavarietyofconnectionpossibilitiesthroughtheuseoftheONVIF2.0standard(OpenNetworkVideoInterfaceForum).Thisallowstheintegrationofvideohardwarefromawiderangeofdifferentmanufacturers.Asimplersetupandhigherflexibilityintheapplicationcompletestherenewalofthevideofeature.SSL encrypted communicationFromversion3.12SSLencryptionforcommunicationofmanagerstoeachotherandtoallclientsisusedconsis-tently.Itisimplementedbydefaultinthesystem.

Technical product description SIMATIC WinCC Open Architecture V3.12

SIMATICWinCCOAOPERATORscreenshots

© ETM GmbH 2013

Page 3: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

3

SVN integrationSVNversionmanagementtoolhasbeenintegratedintothenewversiontosimplifyprojectengineeringinlargeprojectteams.Theintegrationintothegraphicaleditorsignificantlyimprovestheusability.Dist-managementTheDist-managementprovidescentralizedconfigura-tionandasimplerandfasterengineeringindistributedsystems.MultitouchMultitouchenablesintuitiveoperatorguidanceandsim-pleroperation.Zooming,panning,declutteringandsafetwo-handoperationissupported.Layout management „Responsive design“Toautomaticallyadjustthedisplaytothescreensizeduringoperation,theresponsivedesignwasintroduced.ItcanbeimplementedquicklyandeasilyinthegraphicaleditorinWinCCOA3.12.Enhancements in the graphical editorObjectsnapandalignment,anti-aliasing,shadowsandroundedcornersaswellasnewgraphicobjectsallowacleanandefficientcreationofpanels.

Ultralight Client enhancementsThisthinclientisidealfordisplayinmobiledevicesandbrowserswithoutplug-in.WithWinCCOA3.12theper-formancecouldbeincreasedupto300%andsomenewfeatureswereimplemented:embeddedmodules,IFrameforanembeddeddisplayonawebsite,largenumberofnewsupportedwidgets,tooltips,touchgesturesandmanymore.New drivers• Ethernet/IP–nativedriverforRockwellAutomation/

AllenBradleyPLC‘s• S-Bus–forconnectiontoSAIAPCDcontroldevices• IEC61850-newcommunicationstandardfor

high-andmediumvoltageSupported operating systems• Microsoft

– Windows8.1Enterprise– Windows7Ultimate/Enterprise/Professional– WindowsServer2012– WindowsServer2008R2

• Linux– RedHatEnterpriseLinux6.4– OpenSUSE12.3

• OracleSolaris– Solaris10x86

• VMWare– ESXi5.5– ESXi5.1

time to open panel

parsing time(server)

display panel(client)

3.11

3.12

0 1 2 3 4 sec

UltralightClientperformanceenhancements

Dist-managementscreenshot

© ETM GmbH 2013

Page 4: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

4

Platforms• Windows• Linux• OracleSolaris

Object orientation• Referencingofsymbolsandobjects• Inheritanceofstructureddatapointtypes• Objecthierarchy• Directmappingofdatapointtypestoobjects

Redundancy• HotStandby• DisasterRecoverySystem(2x2Redundancy)

TheaimofthisfeatureistoextendtheWinCCOAredundancyconceptthroughasecondHotStandbySystem.TheoperabilityofthesystemneverthelessremainsmaintainedonanothersystemevenintheeventofacompletefailureonthefirstHotStandbySystem.Thus,thedatalossandtheidletimearekeptaslowaspossible.

• Automaticclientswitchover• Automaticrecovery• Automaticprocessimageandhistorysynchronization• Automaticsynchronizationofprojectdata• Redundantnetworks(LAN)• Redundantperipheralcomponentsupport

(SIMATICS7,Applicom)• Splitmodeoperationforupdatesandtesting

Parallel archivingTheparallelHDBandRDBarchivingenablesthestorageofdataintothelocalhistoricaldatabaseandintothecentralOracledatabase.LocalsystemsdonotneedanOracleserverinstallation.ThisarchivingmethodiscompatiblewiththeDisasterRecoverySystem,historicalqueriesandarchivecompressions.

Security• BlockingviaIP-Blacklist• Systemstabilityviaintrinsicsafety• Autonomicsystems• Communication(Standard:SSLencryption,

Option:Secure)• Encryptionofpanels,scriptsandlibraries

SecureThirdpartyauthenticationmechanismbasedonKerberos,developedbyMIT.Absolutesecureprotectionofinternalandexternalcommunication.Authenticationofcommu-nication.Supportssymmetrickeyencryption,nokeywordtransfer.SafetyWinCCOAisSIL3certifiedaccordingtoIEC61508.TUEVSUED(Technicalinspectionagency,SouthGermany)ap-provedthatWinCCOAfunctions,developmentprocessesandsupportingdocumentsareconformtoIECstandard.Aguidelineisprovided,whichdescribesbasicandop-erationalconditionswithinwhichWinCCOAcanbeusedforsafetycriticalprojectsasaprocessvisualizationandcontrolsystem.

Special features of SIMATIC WinCC Open Architecture

Sekundäres Serversystem (SSS)Primäres Serversystem (PSS)

Datenbank in Oracle Cluster

BedienoberflächenFeldgerät oder andere angeschlossene Systeme, wie z.B. OPC UA

WinCC OA Hot Standby

System

WinCC OA Hot Standby

SystemWinCC OA aktiver

Server (A)

WinCC OA passiver Server (B)

WinCC OA aktiver

Server (C)

WinCC OA passiver Server (D)

Datenbank in Oracle Cluster

DisasterRecoverySystem

WinCC OAZentrales System

WinCC OALokales System 1

WinCC OALokales System 2

Oracle DB

RDBManager

RDBManager

HDB HDB

Parallelarchiving

© ETM GmbH 2013

Page 5: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

5

GIS ViewerFullintegrationofstandardizedmapsofcartographicinformation(GIS)withSCADAobjectsinWinCCOA.VideoOfferstheeasypossibilitytointegrateIP-cams,IP-compo-nentswhichfulfilltheONVIF2.0standardandcompletevideomanagementsystemsintoWinCCOA.DuetotheintegrationofSCADAandvideomanagementintoonesystem,theinterfacescanbereducedandthecostsfortraining,maintenanceandoperationarealsoreducedtoaminimum.BACnetBACnetprovidesanintegratedBACnetconformonline-/offline-engineeringsolutionandaspecificobjectlibrary.EToolIntegratedengineeringwithETool–thestandardizedengineeringtoolenablesafast,simpleandcostefficientengineeringwhenSIMATICproductsareused.RecipesRecipemanagementforparametersetsandsetpointlists.Unlimitedrecipetypes,unlimitedrecipequantities,accesscontrol,creationofrecipesfromreal-timeprocessdata.Easy-to-useuserinterface.Import/exportofrecipesasCSV.SchedulerTimerandeventprogramswithsimplegraphicconfigura-tion.Cyclicandacyclic-periodiccall-ups,individualeventsandtimelists,specialdayrules(holidays).Arbitraryactions:valuechanges,recipestarts,reminders,scriptsCommunication CenterProvidesremotealarmsandremoteinformation.AlarmoutputtoSMS,e-mailandfax.AMS (Advanced Maintenance Suite)AdvancedMaintenanceSuite(AMS)isaneasilyconfigu-rablesoftwaretoolforefficientplanning,management,realizationandcontrolofreactiveandpreventivemainte-nance.

TrendingTrendwidgetsforintegrationintocustomizedscreensandatrendapplication(Var-Trend)asaready-to-usetrendapplication.Supports:• Onlineandhistoricalvalues• Valuetrendovertimeorvalue• Timecomparisontrends• Bartrends• Displayofinvalidvalues,alarmrangeand/orvalue

range• Multipleorsharedscales,ruler,automaticlegend• Timeresolutioninms,switchduringruntimebetween

localandUTC-time• Zoom/Unzoomoftrendareas

Reporting• MicrosoftExcelbased

– Timecontrolled,manual,triggered– Timecomparisonandoffsets– Automaticdistributionviae-mail– Automaticcreationofwebpage

• Onlinevalues,history• Compresseddata,SQL,alarms• Diagnosticstools• Audittrail

Trend

© ETM GmbH 2013

Page 6: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

6

Architecture• Trueclient-server-system• Functionalseparationintoseveralprocesses

managers• Loaddistributiononseveralcomputers• Redundancy(HotStandby)• DisasterRecoverySystem• Multi-server-distributedsystemsupto2048systems• Heterogeneousoperatingsystemsandversion

distribution• Multi-monitoroperation• Multi-loginononeworkstation• Multi-usersystem• Eventorientatedprocess• Internalmessagecompression• Safetyfunctionstoincreasereliability(overload

detectionandregulation,queryrestrictions)

Alarm system• VDI3699/DIN19235• Freelydefinablealarmclasseswith255different

prioritiesanddefinitionofalarmcolors(blinking)• Standard,discreteandmultiinstancealarms• Upto255analogalarmranges• Summaryalarms• Automaticfilteringofalarms(Handlingofalarm

floods)• Panelhierarchysummaryalarms• Combinedalarm-andeventscreen,alarmrow

withdefinablecolumnsetandcolorsandadvancedsortingandfiltering

• Storableconfigurations• Directaccesstotheassociatedprocesswindow• Commentsandattendedvaluesonalarms• Onlinechangeofalarmclasses

Process interfaces / drivers• Eventdrivenorcyclicpolling• Severaldifferentdriversatthesametime• Peripherytimestamps• TCP/IP:SIMATICS7,Modbus,Ethernet/IP,

SNMPManager&Agent,BACnet,DynamicLogics• OPC:OPCClient&Server(DA,A&E),

OPCUAClient&Server(DA,AC)• Telecontrol/RTU:SSI,IEC60870-5-101,-104,

DNP3andSINAUT,IEC61850• AdditionaldriversonrequestorwithaC++API

Data model• Objectorienteddatamodelwithfreelydefinableand

easyconfigurablestructure• Manystandardobjectsincluded• Modelingoftechnologicalobjectsinanyhierarchy• Userdefinabletreestructure• Severaldifferentpropertiesdefinableonelements• Type-in-type(referencing)• Inheritance• Groups• Generatedifferentviewsonthedatamodel

Engineering environment• Graphicaleditor• Projecthierarchyeditor(Paneltopology)• Databaseeditor• Controlprogrammingeditor,ScriptWizard• MassdataengineeringandASCIIin/outmanager• Integrationofexternalversionmanagementtools

(CVS,SVN,…)• Simplesymbols,EWOs,Stylesheets

Product details SIMATIC WinCC Open Architecture

© ETM GmbH 2013

Page 7: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

7

Graphical user interface• Drag&Drop• Flexiblewindowtechnique• Platformneutralapplication• Pictureinpicture• Zooming/Panning• Cluttering/Decluttering• Root-,child-andembeddedpanel• Multi-monitoroperation• Multi-selection• Truecolor/synchronousblinking• Upto8picturelayers• Onlinetooltips(multilingual)• Configurablepaneltopology• GUInavigationobjects• Onlineswitchablemultilanguagesupport• UTF-8formultilanguagesupport• Supportsthewidelyusedgraphicalobjectsandwid-

getsalsowithcomprehensiveanimationcapabilities• Supportofexternalwidgets(e.g.ActiveX)• Layoutmanagement“Responsivedesign“

User access• Fulluseraccesssecurityoptionalwithintegrationinto

WindowsActiveDirectory(SingleSignOn)• Variouspermissionlevels• Commandprotocol(Audittrail)• ConformtoFDA21CFRPart11

Internet/Intranet• Web-Server,Webalarmscreen,diagnosticsand

reporting• Webclientbasedonbrowserplug-intechnology• UltralightclientbasedonJavaScript/XHTML• Supportsmainsecurityfunctions(HTTPS,Kerberos

encryption,etc.)• mobileAppWinCCOAOPERATOR

ArchivingComprehensivearchivingoptions• Valuearchivesasflat-filestructure(HDB)• ORACLEarchiving• Parallelarchiving(Oracle,HDB)• Datacompression• Correctionvalues• Laboratoryvalues

Object libraries• WinCCOAstandardobjectlibrary• SIMATICS7objectlibraries(Basic/Advanced)• BACnetobjectlibrary

Application programming / Scripting• InterpreterwithC-syntax(“Control”language)

andmultitaskingsupport• LibrariesandDLL´sforcustomizedextensionsof

thescriptinglanguage• Debugger/diagnosticstools• Supportsalotofexternalinterfaces,like:database

access,ADO,COMandXML,XMLParser,XML-RPC-Interface,UART-andTCP-access

• Completeaccesstoattributesofgraphicalobjects• Know-howprotection(Panels/scriptsencryption)

UTF-8 for multi language supportAllUnicodecharacterscanberepresentedinfourbytes.MultitouchFeatureslikezooming,panning,declutteringandsafetwo-handoperationaresupported.

© ETM GmbH 2013

Page 8: SIMATIC WinCC Open Architecture - · PDF file2 SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree

Further information:

www.siemens.com/wincc-open-architecture FindalsoadditionalbrochuresandtechnicaldescriptionsaboutSIMATICWinCCOpenArchitectureonourwebsite.

Theinformationcontainedinthisbrochuremerelycontaingeneraldescriptionsorperformancecharacteristics,whichmaynotalwaysbeapplicableinthedescribedformtothespecificapplicationcaseormaychangeduetoproductadvancement.Thedesiredperformancecharac-teristicsshallonlybebindingiftheyareexpresslyspecifieduponcon-tractconclusion.AllproductdesignationsmaybebrandsorproductnamesofSiemensAGorothersub-suppliers,whoseutilizationbythirdpartiesfortheirrightsmayviolatetherightsoftheowner.

ETM professional control GmbH

ASiemensCompany

Marktstrasse3

7000Eisenstadt

Austria

Telephone:+43-2682-741-0

www.etm.at

[email protected]

Subjecttochanges11/13

OrderNo.:6ZB5370-1EG02-0BA0

Dispo26100

BR 1112 0.5 EIS 8 En

PrintedinAustria

©ETMprofessionalcontrolGmbH

© ETM GmbH 2013