scada system simatic wincc open architecture - · pdf filesimatic wincc open architecture...

8
siemens.com/wincc-open-architecture SIMATIC WinCC Open Architecture SCADA System

Upload: hathuan

Post on 13-Feb-2018

286 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

siemens.com/wincc-open-architecture

SIMATIC WinCC Open Architecture

SCADA System

Page 2: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

2

SIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica-tions requiring a high degree of client-specific adapta-bility, large and/or complex applications and projects that impose specific system requirements and func-tions. SIMATIC WinCC Open Architecture enables handling with bigger amounts of data with even smal-ler hardware solutions.Highlights SIMATIC WinCC Open Architecture:• Objectorientationfacilitatesefficiencyinengineering

andflexiblesystemexpansions• Upto2,048systemsondistributedsystems• Scalableuptonetworkedredundanthigh-endsystems

withmorethan10milliontags• Platform-independentandavailableforWindows,

Linux,iOSandAndroid• HotStandbyRedundancyandDisasterRecovery

Systemguaranteehighestreliabilityandavailability• SIL3certifiedaccordingIEC61508• Platformforcustomizedsolutions• Comprehensiverangeofdriversandconnectivity:

SIMATICS7,S7-1200,S7-1500,XML,OPC,OPCUA,TCP/IP,Modbus,IEC60870-5-101/104,DNP3,IEC61850,IEC61400,Ethernet/IP,S-Bus...

Supported operating systems• Microsoft

– Windows10– Windows8.1– Windows7SP1– WindowsServer2012R2– WindowsServer2008R2

• Linux– RedHatEnterpriseLinux7.1– OpenSUSE13.2– CentOS7.1

• VMWare– ESXi6

• Supportedoperatingsystemsformobiledevices– iOS8orhigher– AndroidKitKat4.4orhigher

New in SIMATIC WinCC Open Architecture V3.14 Mobile and flexible• TheUltralightClientUX(ULCUX)hasbeenenhanced

fromthepreviousversions.TheULCUXisbasedonHTML5technologyandisusedfordesktopapplica-tions.Noinstallationisrequiredattheclientandusersonlyneedtologinonce(SSO).

• AfullyfunctionalclientforiOSandAndroiddevicesisavailableasBETAversion-whichallowsyoudirectaccesstoyourplantdatanomatterwhen,nomatterwhere.ItprovidesthesamefunctionalityasaFAT-clientandalsoresolution-independentgraphicsforanoptimaloperationonmobiledevices.TheclientforiOSandAndroidisavailableoniTunesAppStoreandGooglePlayStore.TheofficialreleaseforproductiveuseisplannedforQ1/2016.

Technical product description SIMATIC WinCC Open Architecture V3.14

NativeuserinterfaceforiOSandAndroiddevices

Page 3: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

3

Modern and state-of-the-art Acoupleofnewfeatureshavebeenintegratedintothegraphicseditor:• Newanimationfunctionshavebeenbuiltinfor

examplepaneltransitionslikePowerPointandnewanimationsforobjectsaswellasformorecomplexanimationsequences.

• Owntouchgesturescanbetaughtfortherealizationofindividualactions.

• Forindividualpanelandwindowdesigns,switchablecolorschemescanbedefined,forinstancefordayandnight.

• Dedicatedcustomerstylesheets(CSS)canalsobedefinedwhichenabletheindividualdesignofacompleteWinCCOAprojectoracertainwidget.Thissimplifiestheprocessofcustomizingthelookoftheuserinterfaceandsavesvaluableengineeringtime.

• Thetrendmodulehasbeenenhanced.Colorandfillpatternfortrendcurves,pop-upwindowsandtooltipwindowwereadded.Additionalattributesfortrendareasallowaclearerview.

Efficiency• Totakesomeofthestrainfromthesystemduring

majorhistoricdataretrievalprocesses,thenewver-sionhasbeenupgradedtoincludeamessagesplittingfeature.Messagesplittingbreaksthedatapackagedownintosmallerdatarequests.Thisenablesfarfasterdisplayoftherequesteddata,initialresponsetimeissignificantlyshorter,andtheoperatorisabletoanalyzethedatamorequickly.

• UndertheReportingoption,description,aliasandthedatapointelementunithavebeenaddedintherelevantlanguage.Thesecannowalsobedisplayedinthereport.Thepreparedreporttemplatesareavail-ableinEnglishandGerman.

• WinCCOAoffersthepossibilitytocreateyourownwizards.Thesecannowbeimportedorexportedtosharethemandmakethemavailabletootherusersorprojects.

• Setuphasbeencompletelyrevised,makinginstal-lationevensimplerandfaster,andallowingmoreconvenientbrandlabelingofthesetupforOEMs.

Independence• InSIMATICWinCCOpenArchitectureversion3.14,

anumberofdrivershavebeenupgradedtoenableadditionalkeyfunctions:

– TheOPCUAclientnowalsosupportsaccesstohistoricaldata(OPCUAHA).

– Forabetteroverviewofthebrowseddatayoucancreateyourownviewswiththeplantmodel.TheOPCUAclientismulti-clientcapable.

– DriversIEC61850/61400supportdynamicdatasetsand64bitdatatypes.

• SIMATICWinCCOpenArchitectureV3.14runswithfullserverfunctionsontheNanoboxIPC227E/277E.DedicatedlicensepackagesareavailablefortheNanoboxPC.Thisisidealforuseasadataloggerincombinationwithdistributedsystems.

• Forreliableandtrustworthyrecordsinthephar-maceuticalandfoodindustry,thedeclarationofconformityforFDAwasrenewedforSIMATICWinCCOpenArchitecture.

• Windows10isnowalsosupportedbySIMATICWinCCOpenArchitectureversion3.14.

Enhancedtrendmodule

Page 4: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

4

Object orientation• Referencingofsymbolsandobjects• Inheritanceofstructureddatapointtypes• Objecthierarchy• Directmappingofdatapointtypestoobjects• Flexibleplantmodel-differentviewsonthedata

modelrealizable

Redundancy• HotStandby• DisasterRecoverySystem(2x2Redundancy)

TheaimofthisfeatureistoextendtheWinCCOAredundancyconceptthroughasecondHotStandbySystem.TheoperabilityofthesystemneverthelessremainsmaintainedonanothersystemevenintheeventofacompletefailureonthefirstHotStandbySystem.Thus,thedatalossandtheidletimearekeptaslowaspossible.

• Automaticclientswitchover• Automaticrecovery• Automaticprocessimageandhistorysynchronization• Automaticsynchronizationofprojectdata• Redundantnetworks(LAN)• Redundantperipheralcomponentsupport

(SIMATICS7)• Splitmodeoperationforupdatesandtesting

Parallel archivingTheparallelHDBandRDBarchivingenablesthestorageofdataintothelocalhistoricaldatabaseandintothecentralOracledatabase.LocalsystemsdonotneedanOracleserverinstallation.ThisarchivingmethodiscompatiblewiththeDisasterRecoverySystem,historicalqueriesandarchivecompressions.

Security• BlockingviaIP-Blacklist• Systemstabilityduetointrinsicsafety• Autonomicsystems• Communication(Standard:SSLencryption,

Option:Secure)• Encryptionofpanels,scriptsandlibraries

SSL encrypted communicationSSLencryptionforcommunicationofmanagerstoeachotherandtoallclientsisusedconsistently.Itisimple-mentedbydefaultinthesystem.SafetyWinCCOAisSIL3certifiedaccordingtoIEC61508.TUEVSUED(Technicalinspectionagency,SouthGermany)ap-provedthatWinCCOAfunctions,developmentprocessesandsupportingdocumentsareconformtoIECstandard.Aguidelineisprovided,whichdescribesbasicandop-erationalconditionswithinwhichWinCCOAcanbeusedforsafetycriticalprojectsasaprocessvisualizationandcontrolsystem.

Special functions of SIMATIC WinCC Open Architecture

Sekundäres Serversystem (SSS)Primäres Serversystem (PSS)

Datenbank in Oracle Cluster

BedienoberflächenFeldgerät oder andere angeschlossene Systeme, wie z.B. OPC UA

WinCC OA Hot Standby

System

WinCC OA Hot Standby

SystemWinCC OA aktiver

Server (A)

WinCC OA passiver Server (B)

WinCC OA aktiver

Server (C)

WinCC OA passiver Server (D)

Datenbank in Oracle Cluster

DisasterRecoverySystem

WinCC OAZentrales System

WinCC OALokales System 1

WinCC OALokales System 2

Oracle DB

RDBManager

RDBManager

HDB HDB

Parallelarchiving

Page 5: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

5

GIS ViewerFullintegrationofstandardizedmapsofcartographicinformation(GIS)withSCADAobjectsinWinCCOA.VideoOfferstheeasypossibilitytointegrateIP-cams,IP-compo-nentswhichfulfilltheONVIF2.0standardandcompletevideomanagementsystemsintoWinCCOA.DuetotheintegrationofSCADAandvideomanagementintoonesystem,theinterfacescanbereducedandthecostsfortraining,maintenanceandoperationarealsoreducedtoaminimum.BACnetBACnetprovidesanintegratedBACnetconformonline-/offline-engineeringsolutionandaspecificobjectlibrary.RecipesRecipemanagementforparametersetsandsetpointlists.Unlimitedrecipetypes,unlimitedrecipequantities,accesscontrol,creationofrecipesfromreal-timeprocessdata.Easy-to-useuserinterface.Import/exportofrecipesasCSV.SchedulerTimerandeventprogramswithsimplegraphicconfigur-ation.Cyclicandacyclic-periodiccall-ups,individualeventsandtimelists,specialdayrules(holidays).Arbitraryactions:valuechanges,recipestarts,reminders,scriptsReporting• Web-basedReportingInterface(SOAP)

– EclipseBIRT– CrystalReports– SIMATICInformationServer– MicrosoftExcel– SeveralReportingtemplatesforECLIPSEBIRT

• Onlinevalues,history• Compresseddata,SQL,alarms• Diagnosticstools• Audittrail

TrendingTrendwidgetsforintegrationintocustomizedscreensandatrendapplication(Var-Trend)asaready-to-usetrendapplication.Supports:• Onlineandhistoricalvalues• Valuetrendovertimeorvalue• Timecomparisontrends• Bartrends2Dand3D• Colorandfillingpatternfortrendcurves• Displayofinvalidvalues,alarmrangeand/orvalue

range• Multipleorsharedscales,ruler,automaticlegend• Timeresolutioninms,switchduringruntimebetween

localandUTC-time• Zoom/Unzoomoftrendareas

Communication CenterProvidesremotealarmsandremoteinformation.AlarmoutputtoSMSande-mail.AMS (Advanced Maintenance Suite)AdvancedMaintenanceSuite(AMS)isaneasilyconfigu-rablesoftwaretoolforefficientplanning,management,realizationandcontrolofreactiveandpreventivemainte-nance.

Trend

Page 6: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

6

Architecture• Client-server-system• Functionalseparationintoseveralprocesses

(managers)• Loaddistributiononseveralcomputers• Redundancy(HotStandby)• DisasterRecoverySystem• Multi-server-distributedsystemsupto2048systems• Heterogeneousoperatingsystemsandversion

distribution• Multi-monitoroperation• Multi-loginononeworkstation• Multi-usersystem• Eventorientatedprocess• Internalmessagecompression• Safetyfunctionstoincreasereliability(overload

detectionandregulation,queryrestrictions)

Alarm system• VDI3699/DIN19235• Freelydefinablealarmclasseswith255different

prioritiesanddefinitionofalarmcolors(blinking)• Standard,discreteandmultiinstancealarms• Upto255analogalarmranges• Summaryalarms• Automaticfilteringofalarms(Handlingofalarm

floods)• Panelhierarchysummaryalarms• Combinedalarm-andeventscreen,alarmrow

withdefinablecolumnsetandcolorsandadvancedsortingandfiltering

• Storableconfigurations• Directaccesstotheassociatedprocesswindow• Commentsandattendedvaluesonalarms• Onlinechangeofalarmclasses

Process interfaces / drivers• Eventdrivenorcyclicpolling• Severaldifferentdriversatthesametimeonone

server• Peripherytimestamps• TCP/IP:SIMATICS7,Modbus,Ethernet/IP,

SNMPManager&Agent,BACnet• OPCUA:DA,AC(Client&Server),HA(Client)

OPC:DA,AE,HDA(Client&Server)• Telecontrol/RTU:SSI,IEC60870-5-101,-104,

DNP3,SINAUT,IEC61850/61400• AdditionaldriversonrequestorwithaC++API

Data model• Objectorienteddatamodelwithfreelydefinableand

easyconfigurablestructure• Manystandardobjectsincluded• Modelingoftechnologicalobjectsinanyhierarchy• Userdefinabletreestructure• Severaldifferentpropertiesdefinableonelements• Type-in-type(referencing)• Inheritance• Groups• Generatedifferentviewsonthedatamodel

Engineering environment• Graphicaleditor• Projecthierarchyeditor(Paneltopology)• Projecteditor• Databaseeditor• Controlprogrammingeditor,ScriptWizard• MassdataengineeringandASCIIin/outmanager• Integrationofexternalversionmanagementtools

(CVS,SVN,…)• Simplesymbols,EWOs,stylesheets,colorschemes• Frameworkforengineering&applicationuserinter-

faces

Product details SIMATIC WinCC Open Architecture

Page 7: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

7

Graphical user interface• Drag&Drop• Flexiblewindowtechnique• Platformneutralapplication• Pictureinpicture• Zooming/Panning• Cluttering/Decluttering• Root-,child-andembeddedpanel• Multi-monitoroperation• Multi-selection• Truecolor/synchronousblinking• Upto8picturelayers• Onlinetooltips(multilingual)• Configurablepaneltopology• GUInavigationobjects• Onlineswitchablemultilanguagesupport• UTF-8formultilanguagesupport• Supportsthewidelyusedgraphicalobjectsandwid-

getsalsowithcomprehensiveanimationcapabilities• Supportofexternalwidgets(e.g.ActiveX)• Layoutmanagement“Responsivedesign“• Multitouchsupport:zooming,panning,decluttering,

safetwo-handoperationandcustomgestures• Animations:paneltransition,objectanimations,

animationgroups

User access• Fulluseraccesssecurityoptionalwithintegrationinto

WindowsActiveDirectory(SingleSignOn)• Variouspermissionlevels• Commandprotocol(Audittrail)• ConformtoFDA21CFRPart11

Internet/Intranet• Webserver,webalarmscreen,diagnosticsand

reporting• Webclientbasedonbrowserplug-intechnology• UltralightclientULCUX(HTML5)• mobileAppWinCCOAOPERATOR(iOS)• Mobileclient(iOSandAndroid)• Supportsmainsecurityfunctions(HTTPS,SSL,

Kerberosencryption,etc.)

ArchivingComprehensivearchivingoptions• Valuearchivesasflat-filestructure(HDB)• ORACLEarchiving• Parallelarchiving(Oracle,HDB)• DBLogger(MSSQL,MySQL,ORACLE)• Datacompression• Correctionvalues• Laboratoryvalues• Web-basedreportinginterface(SOAP)• ReportingtemplatesbasedonEclipseBIRT

Object libraries• WinCCOAstandardobjectlibrary• SIMATICS7objectlibraries(Basic/Advanced)• BACnetobjectlibrary

Application programming / Scripting• InterpreterwithC-syntax(“Control”language)

andmultithreadingsupport• LibrariesandDLL´sforcustomizedextensionsof

thescriptinglanguage• Debugger/diagnosticstools• Supportsalotofexternalinterfaces,like:database

access,ADO,COMandXML,XMLParser,XML-RPC-Interface,UART-andTCP-access,WebSockets

• Completeaccesstoattributesofgraphicalobjects• Know-howprotection(Panels/scriptsencryption)

UTF-8 for multi language supportAllUnicodecharacterscanberepresentedinfourbytes.

Page 8: SCADA System SIMATIC WinCC Open Architecture - · PDF fileSIMATIC WinCC Open Architecture forms part of the SIMATIC HMI range and is designed for use in applica- ... and flexible system

Further information:

www.siemens.com/wincc-open-architecture FindalsoadditionalbrochuresandtechnicaldescriptionsaboutSIMATICWinCCOpenArchitectureonourwebsite.Security information:Siemensprovidesproductsandsolutionswithindustrialsecurityfunctionsthatsupportthesecureoperationofplants,solutions,machines,equipmentand/ornetworks.Theyareimportantcomponentsinaholisticindustrialsecurityconcept.Withthisinmind,Siemens’productsandsolutionsundergocontinuousdevelopment.Siemensrecommendsstronglythatyouregularlycheckforproductupdates.ForthesecureoperationofSiemensproductsandsolu-tions,itisnecessarytotakesuitablepreventiveaction(e.g.cellprotectionconcept)andintegrateeachcompo-nentintoaholistic,state-of-the-artindustrialsecuritycon-cept.Third-partyproductsthatmaybeinuseshouldalsobeconsidered.Formoreinformationaboutindustrialsecurity,visithttp://www.siemens.com/industrialsecurity.Tostayinformedaboutproductupdatesastheyoccur,signupforaproduct-specificnewsletter.Formoreinfor-mation,visithttp://support.automation.siemens.com.

Theinformationcontainedinthisbrochuremerelycontaingeneraldescriptionsorperformancecharacteristics,whichmaynotalwaysbeapplicableinthedescribedformtothespecificapplicationcaseormaychangeduetoproductadvancement.Thedesiredperformancecharac-teristicsshallonlybebindingiftheyareexpresslyspecifieduponcon-tractconclusion.AllproductdesignationsmaybebrandsorproductnamesofSiemensAGorothersub-suppliers,whoseutilizationbythirdpartiesfortheirrightsmayviolatetherightsoftheowner.

ETM professional control GmbH

ASiemensCompany

Marktstrasse3

7000Eisenstadt

Austria

Telephone:+43-2682-741-0

www.etm.at

[email protected]

Subjecttochanges01/16

OrderNo.:6ZB5370-1EG02-0BA0

Dispo26100

BR 0116 1.0 EIS 8 En

PrintedinAustria