protection ccum 21 - system controls & switchgears reverse... · 2. ccum 21 relay withdrawn...

4
1 GRID PROTECTION Features High speed directional element. • Robust construction of less than 3% rat - ed single phase power. Wide range of definite time settings. • Consistent timing. • Comprehensive range of auxiliary unit ratings. • Drawout case and tropicalised finish. Application Type CCUM 21 definite time reverse power relay provides a sensitive and economical means of detecting motoring conditions in diesel alternators and back pressure turbines. Faster clearance time can be ob- tained for lower values of reverse power than that are possible with inverse definite minimum time delay relays. Description Basically relay type CCUM is a high speed induction cup unit (type CCD). The cup contact initiates a static timing unit (type VTT) which provides the output contacts for alarm and trip functions. Typical exter - nal and internal connections are shown in Figure 1 Technical data Ratings • Current 1A or 5A at 50 Hz. • Voltage 110V at 50 Hz. Thermal rating • Continuous 2 x rated current at 110% Rated voltage • Short time 20 x rated current for 3 sec - onds. Maximum torque angle 30º when connected as shown in Figure1 (applied voltage lagging applied current. This corresponds to Unity Power Factor in the system). Sensitivity About 1% of rated voltage with 1 to 15 times rated current or 3% of rated voltage with 0.4 to 40 times rated current. Nomi- nal power setting less than 3% of rated sin- gle phase power. AC burdens • Current circuit : 1VA at rated current. • Voltage circuit : 9VA at rated voltage. Operating time • 1-10 seconds as standard. • Other time ranges: 0.5 - 5s, 2.5 - 25s, 6 - 60s and 12 - 120s. - cal means of detecting motoring conditions in diesel alternators and back pres- sure turbines. Faster clearance time can be obtained for lower values of re- verse power than that are possible with inverse definite minimum time delay relays. Customer Benefits • Economial means of detect - ing motoring conditions. • Robust construction. • Faster fault clearance. • Draw out feature Reverse Power Relay CCUM 21 CCUM 21 definite time reverse power relay provides a sensitive and economi

Upload: ngoquynh

Post on 11-Mar-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: PROTECTION CCUM 21 - System Controls & Switchgears Reverse... · 2. CCUM 21 relay withdrawn from case. CCUM 21. Case. 1½D vertical draw out case suitable for flush mounting. Finished

1

GRID

PROTECTION

Features

• High speed directional element.

• Robust construction of less than 3% rat-ed single phase power.

• Wide range of definite time settings.

• Consistent timing.

• Comprehensive range of auxiliary unit ratings.

• Drawout case and tropicalised finish.

Application

Type CCUM 21 definite time reverse power

relay provides a sensitive and economical means of detecting motoring conditions in diesel alternators and back pressure turbines. Faster clearance time can be ob-tained for lower values of reverse power than that are possible with inverse definite minimum time delay relays.

Description

Basically relay type CCUM is a high speed induction cup unit (type CCD). The cup contact initiates a static timing unit (type VTT) which provides the output contacts for alarm and trip functions. Typical exter-nal and internal connections are shown in Figure 1

Technical data

Ratings

• Current 1A or 5A at 50 Hz.

• Voltage 110V at 50 Hz.

Thermal rating

• Continuous 2 x rated current at 110% Rated voltage

• Short time 20 x rated current for 3 sec-onds.

Maximum torque angle

30º when connected as shown in Figure1 (applied voltage lagging applied current.

This corresponds to Unity Power Factor in the system).

Sensitivity

About 1% of rated voltage with 1 to 15 times rated current or 3% of rated voltage with 0.4 to 40 times rated current. Nomi-nal power setting less than 3% of rated sin-gle phase power. AC burdens• Current circuit : 1VA at rated current.• Voltage circuit : 9VA at rated voltage.

Operating time• 1-10 seconds as standard.• Other time ranges: 0.5 - 5s, 2.5 - 25s,

6 - 60s and 12 - 120s.

-cal means of detecting motoring conditions in diesel alternators and back pres-sure turbines. Faster clearance time can be obtained for lower values of re-verse power than that are possible with inverse definite minimum time delay relays.

Customer Benefits• Economial means of detect-

ing motoring conditions.• Robust construction.• Faster fault clearance.• Draw out feature

Reverse Power RelayCCUM 21

CCUM 21 definite time reverse power relay provides a sensitive and economi

Page 2: PROTECTION CCUM 21 - System Controls & Switchgears Reverse... · 2. CCUM 21 relay withdrawn from case. CCUM 21. Case. 1½D vertical draw out case suitable for flush mounting. Finished

2

CCUM 21 relay withdrawn from case

CCUM 21

Case

1½D vertical draw out case suitable for flush mounting. Finished egg-shell black and tropicalised. Suitable trip isolating switches, CT shorting switches, and provision for maintaining the under voltage trip circuits on withdrawal of the relay unit from the case, are provided on the cradle assembly/case.

Figure 1: Typical external and internal connections for type CCUM 21 relay

DIMENSIONSCase Height Width Depth*1½D 362 mm 170 mm 203 mm

*Add 76 mm for maximum length of terminal studs, alternatively, 29 mm for terminal screws.

Contact ratings

Current Make and carry Make and carry continuously for 3 seconds

Break

AC 1250VA with maxima of 5A and 660V 7500VA with maxima of 30A and 660V 1250VA with maxima of 5Aand 660V

DC 1250W with maxima of 5A and 660V 7500W with maxima of 30A and 660V 100W (resistive) 50W (inductive) with maxima of 5A and 660V

Page 3: PROTECTION CCUM 21 - System Controls & Switchgears Reverse... · 2. CCUM 21 relay withdrawn from case. CCUM 21. Case. 1½D vertical draw out case suitable for flush mounting. Finished

3

Auxiliary supply

• 30, 110, 220V dc Standard.

• 220, 250V 50 Hz ac can be given.

• Operates satisfactorily between 75 - 120% of rated volts (dc) and

80 - 115% of rated volts (ac).

Auxiliary burden

• Approx. 1.26, 4.46, 9.1 watts for 30, 110, 220 volts dc respectively.

• Approx. 2.3VA for ac auxiliary supply.

Contacts

2 pairs (S/R) in any combination of normally open and normally closed.

Operation indicator

Hand reset mechanical operation indicator provided on timer unit.

Insulation

The relay meets the requirements of IS 3231, IEC-255-5 series C-2 KV

for 1 minute.

Information required with order

1. Current rating.

2. Operating time range.

3. Contact combination.

4. Auxiliary supply.

CCUM 21

Page 4: PROTECTION CCUM 21 - System Controls & Switchgears Reverse... · 2. CCUM 21 relay withdrawn from case. CCUM 21. Case. 1½D vertical draw out case suitable for flush mounting. Finished

4

GRID

Figure 2 : Case and panel cut-out dimensions for case 1 1/2 D ( All dimensions in mm)

ALSTOM T&D INDIA LIMITEDPallavaram Works19/1, G.S.T. Road,Pallavaram, Chennai - 600 043Tel: 91-44-2264 8000Fax: 91-44-2264 0040

ALSTOM T&D Worldwide Contact Centre:http://www.alstom.com/contactcentre/Tel.: +44 (0) 1785 250 070

www.grid.alstom.com

CCUM 21

“Alst

om lo

go a

nd a

ny a

ltern

ativ

e ve

rsio

n th

ereo

f are

trad

emar

ks a

nd s

ervi

ce m

arks

of A

lstom

. The

oth

er n

ames

men

tione

d, re

gist

ered

or n

ot, a

re th

e pr

oper

ty o

f the

ir re

spec

tive

com

pani

es. T

he te

chni

cal a

nd o

ther

dat

a co

ntai

ned

in

the

docu

men

t are

pro

vide

d fo

r inf

orm

atio

n on

ly. N

eith

er A

LSTO

M, i

ts o

ffice

rs n

or e

mpl

oyee

s ac

cept

resp

onsib

ility

for o

r sho

uld

be ta

ken

as m

akin

g an

y re

pres

enta

tion

or w

arra

nty

(whe

ther

exp

ress

or i

mpl

ied)

as

to th

e ac

cura

cy o

r co

mpl

eten

ess

of s

uch

data

or t

he a

chie

vem

ents

of a

ny p

roje

cted

per

form

ance

crit

eria

whe

re th

ese

are

indi

cate

d. N

o lia

bilit

y is

acce

pted

for a

ny re

lianc

e pl

aced

upo

n th

e in

form

atio

n co

ntai

ned

in th

is br

ochu

re. A

lstom

rese

rves

the

right

to

revi

se o

r cha

nge

thes

e da

ta a

t any

tim

e w

ithou

t fur

ther

not

ice.”