Page 1: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron
Page 2: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Description The short reaction times and high power to weight ratios

are achieved by sophisticated designs developed by Chemring Energetics UK Ltd over many years. Within the metal body of each device, rapid expansion of hot

combustion products generates very high pressures which

are used to do mechanical work, e.g. drive a piston or cutter. Electric initiation is achieved by the use of specifically

developed fuzeheads which are sufficiently varied to offer a range of sensitivities. To take into account the wide range of uses to which these devices are subjected,

Metron Actuators may be supplied with different fuzeheads e.g. when power supplies are limited a fuzehead with high sensitivity may be required whereas a low

sensitivity may be preferred under circumstances where spurious electric current can be induced. Their ability to rapidly convert small electrical signals into high mechanical work output, their compact size, high

reliability and good environmental resistance make Metron Actuators ideal for automatic or remote controlled applications in Fire Protection, Security,

Defence and Aerospace industries.

Metron Actuators are highly reliable, compact

single shot devices which can push, pull, cut or

shear with a power to weight ratio in excess of

10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse, a

rate which is almost impossible to achieve

with a mechanical source of energy.

Nomenclature Each device in the Metron Actuators range is

uniquely defined by a standard nomenclature.

Actuators are grouped into five main types:

Nomenclature

Piston Protractors DR2000 series

Retractors DR3000 series

Gas Generators DR4000 series

Guillotines DR5000 series

Igniters DR9000 series

Within each of these series a range of cable finishes

may be supplied. The cable finish is defined by C(x) where x is a number corresponding to the type of finish e.g.

DR2003/C1 corresponds to a piston protractor defined as DR2003 with cable finish C1. The electrical characteristics are defined by the DR

number within each series e.g. DR2003 uniquely

determines the physical dimensions and the electrical characteristics of that protractor. Numerous types of existing cable finishes and

harnesses can be supplied with the actuators. Bespoke cable finishes can also be added to customer’s requirements. Please contact the sales

department for more information.

Metron Actuators

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 3: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Fusehead Examples Type 1 Type 2 Type 3

Nominal Energy 6 millijoules 30 millijoules 600 millijoules

Resistance Range (ohms) (1) 0.9 - 1.6 0.15 - 0.30 10 - 16

Maximum No Fire current (2):

30 sec pulse 0.15A 0.4A 0.03A

0.05 sec pulse 0.3A 0.95A 0.05A

Minimum Single Firing Current:

D.C. 0.6A 2.5A 0.14A

10 ms pulse 0.9A 0.95A 0.05A

Recommended Single Firing Current 1A 5A 0.15A

Recommended Series Firing Current 3A 10A 0.3A

Maximum Monitoring Current 0.01A 0.01A 0.01A

(1) The completed device resistance depends on cable type.

(2) The fusehead may be desensitised by being subjected to currents between the maximum recommended monitoring test current and the No Fire Current (inclusive) and is not guaranteed to fire afterwards.

Operating Characteristics Single Actuator Firing

The required battery or power supply voltage may be calculated from the product of the recommended firing current (I) for the device in question and the total circuit resistance (R) i.e. V = IR Multiple Actuator Firing When more than one actuator is to be fired in a circuit, Chemring Energetics UK recommend series firing as being

the simplest method. In multiple firing circuits all actuators must be of the same electrical sensitivity (eg Type 1). On no account must devices of different manufacture or electrical sensitivity be mixed in the same circuit. Where parallel firing is considered necessary, extreme care must be taken to ensure balanced resistances and the

possibility of the actuator circuit remaining intact after firing must be borne in mind.

Insulation Before firing, an insulation of not less than 100 megaohms at 100 V DC exists between the shunted leads and the

body of the device. Electrostatic Sensitivity Metron Actuators will withstand a discharge of 300pf at 5kV minimum between the shunted leads and the body of

the device. Metron Actuators can be designed to withstand higher levels of electrical sensitivity if required. Device Function Time The function times of the actuators vary with current applied and load to be moved. Typical values may be 10-20 milliseconds.

Hazardous Atmospheres

1. Incendivity tests in 9% methane/ air mixtures have been carried out in accordance with the M and Q Testing Memorandum No. 13 published by the UK Health and Safety Executive. The tests gave no ignition in 200

firings of ‘Metron’ protractors. 2. Metron protractors have been fired by an I.S. low voltage electrical supply in an explosive gas mixture. The test mixture was 40% hydrogen, 20% oxygen and 40% nitrogen, as described in Appendix1, of BASEEFA.

Certification Standard SFA 3007:1981. The tests (conducted in the gas mixture giving the most severe conditions specified in accepted standards for apparatus intended to be used in hydrogen/ air mixtures) gave no ignitions in 200 firings.

Metron Actuators

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 4: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

The current needed to operate a number of

actuators in series is greater than that

required for a single device.

The reasons for this may be explained in the

following manner.

Consider a series of Metron Actuators to which a

uniform direct current is suddenly applied. Before

any one device can operate the fuzehead must be

traversed by the current for a certain minimum

period of time, usually the order of a few

milliseconds, during which the wire heats up to the

ignition temperature of the pyrotechnic mixture.

The minimum time is termed the ‘excitation time’.

In practice, the excitation time will vary slightly from one actuator to another because of inevitable small

manufacturing variations. After the fuzehead has

received this minimum dosage of current there will

normally be a further lapse before the ignition has

spread throughout the fuzehead and broken the

electric circuit. The time from the first application of

current to the rupture of the circuit is referred to as

the ‘lag time’.

For all Metron Actuators, in series, in an electric

circuit to operate successfully the shortest lag time

of any of them must exceed the longest excitation

time of any of them. In other words, every one of

the devices must receive the full quota of electric

energy to cause its ignition before any single one of

them has completed its lag time and broken the

circuit.

The operating characteristics of Metron Actuators can be represented on a diagram as in Figure 1. Here,

the line A P B shows the relationship between current and lag time, while CPD shows the corresponding

relationship between current and maximum excitation time. Now consider the current i. From the curve it

will be seen that the most rapid actuator will break the circuit in T3 milliseconds, where as the least

sensitive actuator requires the current to flow for at least T4 milliseconds to enable it to operate. At a

higher current i2, however, the excitation time T1 is less than time T2 which is allowed by the most rapid

actuator and hence the least sensitive actuator in the circuit will have ample time to receive its full quota of

current before the circuit is broken at T2.

Somewhere between the two current values i1 and i2 corresponding to the cross-over point P, there is a

value is which will be the minimum operating current for the series considered. In practice, is is always

higher than the minimum operating current io for a single actuator of the same type.

When more than one actuator is to be fired in a circuit, Chemring Energetics UK recommends series firing

as being the simplest method. In a multiple firing circuit all actuators must be of the same electrical

sensitivity. On no account must devices of different manufacture or electrical sensitivity be mixed in the

same circuit. When parallel firing is considered necessary, extreme care must be taken to ensure balanced resistances and the possibility of the actuator circuit remaining intact after firing must be kept in mind. The

principle of series and parallel firing of actuators and detonators is well established.

Metron Actuators in Series

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 5: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2003 Metron Actuator and example cable finish

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

DR2003 Metron Actuator

Energetic Systems

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 1.18 Joules

Typical Peak Thrust 1100 Newtons

Minimum Piston Stroke Length 3.4 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 6 millijoules

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

30 sec Pulse: 0.15A

0.050 sec Pulse: 0.3A

Min Single Fire Current:

DC: 0.6A

10ms Pulse: 0.9A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

Page 6: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2005 Metron Actuator and example cable finish

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 3.43 Joules

Typical Peak Thrust 2300 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 6 millijoules

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

30 sec Pulse: 0.15A

0.050 sec Pulse: 0.3A

Min Single Fire Current:

DC: 0.6A

10ms Pulse: 0.9A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

DR2005 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 7: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2006 Metron Actuator and typical force/time profile

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 4.9 Joules

Typical Peak Thrust 2300 Newtons

Minimum Piston Stroke Length 13.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 6 millijoules

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

30 sec Pulse: 0.15A

0.050 sec Pulse: 0.3A

Min Single Fire Current:

DC: 0.6A

10ms Pulse: 0.9A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

DR2006 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 8: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2014 Metron Actuator and typical force/time profile

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 4.9 Joules

Typical Peak Thrust 1800 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 6 millijoules

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

30 sec Pulse: 0.15A

0.050 sec Pulse: 0.3A

Min Single Fire Current:

DC: 0.6A

10ms Pulse: 0.9A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

DR2014 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 9: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2024 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack Metron

Actuators can be shipped through normal

parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 4.9 Joules

Typical Peak Thrust 1800 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 30 millijoules

Resistance Range 0.15-0.55 Ohms

Max No Fire Current:

30 sec Pulse: 0.4A

0.050 sec Pulse: 0.9A

Min Single Fire Current:

DC: 2.5A

10ms Pulse: 4A

Recommended Single Firing

Current 5A

Recommended Series Firing

Current 10A

DR2024 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 10: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2027 Metron Actuator and typical force/time profile

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 3.43 Joules

Typical Peak Thrust 2300 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 600 microjoules

Resistance Range 10—16 Ohms

Max No Fire Current:

30 sec Pulse: 0.03A

0.050 sec Pulse: 0.05A

Min Single Fire Current:

DC: 0.14A

10ms Pulse: 0.145A

Recommended Single Firing

Current 0.22A

Recommended Series Firing

Current 0.7A

DR2027 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 11: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2028 Metron Actuator and typical force/time profile

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 3.43 Joules

Typical Peak Thrust 2300 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 30 millijoules

Resistance Range 0.15-0.55 Ohms

Max No Fire Current:

30 sec Pulse: 0.4A

0.050 sec Pulse: 0.9A

Min Single Fire Current:

DC: 2.5A

10ms Pulse: 4A

Recommended Single Firing

Current 5A

Recommended Series Firing

Current 010A

DR2028 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 12: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2032 Metron Actuator

Metron Actuators are single shot devices which rapidly convert small electrical signals into

useful mechanical work output. The DR2032 Miniature Actuator is designed to withstand high

acceleration forces such as experienced in gun barrels.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy

themselves with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet

PSDS-67, and User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 0.02 Joules

Minimum Peak Thrust 160 Newtons

Minimum Piston Stroke Length 4 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

0.050 sec Pulse: 0.06A

Min Single Fire Current:

10ms Pulse: 0.16A

Recommended Single Firing

Current 0.24A

Recommended Series Firing

Current 0.7A

DR2032 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 13: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

3D model of a DR2037 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Specification (values shown are representative)

Resistance Range: 0.65—1.3 Ohms

Max No Fire Current:

5 minutes: 1A/1W

Min Single Fire Current:

10ms pulse: 5A

50ms pulse: 3.5A

Recommended Single Firing

Current 5A

Minimum Peak Thrust 1600 Newtons

Minimum Output Energy 6.9 Joules

Operating Temperature - 40°C to + 80°C

No Fire Threshold 2.1 Watts

Maximum Monitoring Current 0.01A

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack Metron

Actuators can be shipped through normal

parcel post . 38.5

815

20

37

34

5

BRASS HEXAGONAL

END CAPBRASS BODYSTANLESS STEEL PISTON

(FIRED POSTION SHOWN)

M8

X 0

.75

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

Metron Actuators are designed to produce mechanical

work from an electrical impulse. The work output is

produced by a stainless steel piston propelled through

the base of the actuator by a small propellant charge.

The force available is at a maximum initially and reduces

as the piston extends. The piston is captive and will

stop at the maximum travel. The piston can be stalled

prior to this in the application if desired. The design is

such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

The DR2037 Actuator incorporates an ignition system,

designated as DR1000/SA/7, capable of withstanding,

without firing, an applied pulse of one amp one watt for five minutes. The Igniter has been characterised

according to an approved UK Defence Ordnance Safety

Group method and reported in DMP11773.

DR2037 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 14: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2053 bottle opener

Metron Actuators are single shot devices which rapidly convert small electrical signals into

useful mechanical work output. Metron bottle openers are designed to vent 8 gram CO2

bottles in under 5 seconds. This combination can provide a lightweight solution for

pressurisation of fire suppression systems or inflation of flotation devices.

Shipping

Our standard range of Metron Actuators are classified

as non Explosive and are exempt from UN class 1.

In the approved pack Metron Actuators can be shipped

through normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Piston Stroke Length 3.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 600 microjoules

Resistance Range 10—16 Ohms

Max No Fire Current:

0.050 sec Pulse: 0.06A

Min Single Fire Current:

10ms Pulse: 0.2A

Recommended Single Firing

Current 0.24A

Recommended Series Firing

Current 0.7A

DR2053 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 15: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2057 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are classified

as non Explosive and are exempt from UN class 1.

In the approved pack Metron Actuators can be shipped

through normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 4 Joules

Minimum Piston Stroke Length 12.5 mm

Shelf Life (ambient) 10 years

Operating Temperature -40°C to +70°C

Resistance Range 1.3—2.2 Ohms

Max No Fire Current:

500 millisecond Pulse: 0.23A

Min Single Fire Current:

DC: 2.5A

10ms Pulse: 0.75A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

Metron Actuator approved pack

DR2057 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 16: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2069 Metron Actuator and example cable finish

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack Metron

Actuators can be shipped through normal

parcel post.

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 3.43 Joules

Typical Peak Thrust 2300 Newtons

Minimum Piston Stroke Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 600 microjoules

Resistance Range 10—16 Ohms

Max No Fire Current:

30 sec Pulse: 0.03A

0.050 sec Pulse: 0.05A

Min Single Fire Current:

DC: 0.14A

10ms Pulse: 0.145A

Recommended Single Firing

Current 0.22A

Recommended Series Firing

Current 0.7A

DR2069 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 17: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2075 bottle opener

Metron Actuators are single shot devices which rapidly convert small electrical signals into

useful mechanical work output. Metron bottle openers are designed to vent 8 gram CO2

bottles in under 5 seconds. This combination can provide a lightweight solution for

pressurisation of fire suppression systems or inflation of flotation devices.

Shipping

Our standard range of Metron Actuators are classified

as non Explosive and are exempt from UN class 1.

In the approved pack Metron Actuators can be shipped

through normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Piston Stroke Length 3.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to

+70°C

Resistance Range 1.3-2.2 Ohms

Max No Fire Current:

500 ms Pulse: 0.25A

Min Single Fire Current:

10ms Pulse: 1A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

DR2075 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 18: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2076 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

They are highly reliable, compact devices which can

push, pull, cut or shear with a power to weight ratio in

excess of 10,000:1. They operate within milliseconds of

receiving the appropriate electrical impulse. The devices are hermetically sealed and are maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Metron Actuators are approved by the Loss Prevention

Certification Board and the Underwriters Laboratories.

Specifications

Minimum Work Output 4.9 Joules

Typical Peak Thrust 1800 Newtons

Minimum Piston Stroke

Length 9.5 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to +70°C

Nominal Input Energy 600 microjoules

Resistance Range 10-16 Ohms

Max No Fire Current:

5 sec Pulse: 0.045A

Min Single Fire Current:

10ms Pulse: 0.16A

Recommended Series Firing

Current 1A

DR2076 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 19: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2077 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Specification (values shown are representative)

Resistance Range 0.65—1.9 Ohms

Max No Fire Current:

5 minutes : 1A/1W

Min Single Fire Current:

10ms pulse: 5A

50ms pulse: 3.5A

Recommended Single Firing

Current 5A

Minimum Output Energy 3 Joules

Operating Temperature - 46°C to + 80°C

No Fire Threshold 2.1 Watts

Maximum Monitoring Current 0.01A

Shipping

Our standard range of Metron Actuators are classified

as non Explosive and are exempt from UN class 1. In

the approved pack Metron Actuators can be shipped

through normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves

with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and

User Instruction Sheet Guide-39.

Description

Metron Actuators are designed to produce mechanical

work from an electrical impulse. The work output is

produced by a stainless steel piston propelled through

the base of the actuator by a small propellant charge.

The force available is at a maximum initially and reduces

as the piston extends. The piston is captive and will

stop at the maximum travel. The piston can be stalled

prior to this in the application if desired. The design is

such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

The DR2077 Actuator incorporates an ignition system,

designated as DR1000/SA/7, capable of withstanding,

without firing, an applied pulse of one amp one watt for five minutes. The Igniter has been characterized

according to an approved UK Defence Ordnance Safety

Group method and reported in DMP11773.

Metron Actuator approved pack

DR2077 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 20: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2085 Metron Actuator

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output.

Specification (values shown are representative)

Resistance Range: 0.65—1.9 Ohms

Max No Fire Current:

5 minutes : 1A/1W

Min Single Fire Current:

10ms pulse 5A

50ms pulse: 3.5A

Recommended Single Firing

Current: 5A

Minimum Output Energy 3 Joules

Operating Temperature - 40°C to + 70°C

Can withstand short periods at - 46°C to + 150°C

No Fire Threshold 2.1 Watts

Maximum Monitoring Current 0.01A

Life (at ambient temperature) 15 years

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt from

UN class 1.

In the approved pack Metron Actuators can be

shipped through normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy

themselves with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet

PSDS-67, and User Instruction Sheet Guide-39.

Description

Metron Actuators are designed to produce mechanical

work from an electrical impulse. The work output is

produced by a stainless steel piston propelled through

the base of the actuator by a small propellant charge.

The force available is at a maximum initially and reduces

as the piston extends. The piston is captive and will

stop at the maximum travel. The piston can be stalled

prior to this in the application if desired. The design is

such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations.

The DR2085 Actuator incorporates an ignition system,

designated as DR1000/SA/7, capable of withstanding,

without firing, an applied pulse of one amp one watt for five minutes. The Igniter has been characterized

according to an approved UK Defence Ordnance Safety

Group method and reported in DMP11773.

DR2085 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 21: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

DR2094 Metron Actuator and a selection of High Power actuators.

Metron Actuators are single shot devices which

rapidly convert small electrical signals into useful

mechanical work output. High Power Actuators

have been developed for applications where

increased power and/ or increased temperature

range is required.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt

from UN class 1. In the approved pack

Metron Actuators can be shipped through

normal parcel post .

Actuator shown is a basic cable finish – other cable finishes available on request. All information is intended for guidance only. Recipients should satisfy themselves with the suitability of the Metron actuator for their particular purpose. Additional safety information can be sought from Product Safety Data Sheet PSDS-67, and User Instruction Sheet Guide-39.

Description

The Chemring Energetics UK range of Actuators are

well known in the Defence, Safety and Security markets.

The work output is produced by a stainless steel piston

propelled through the base of the actuator by a small

propellant charge. The force available is at a maximum

initially and reduces as the piston extends. The piston is

captive and will stop at the maximum travel. The design

is such that the product is non explosive and can be

stored and transported without recourse to explosive

goods regulations. They are highly reliable, compact

devices which can push, pull, cut or shear with a power

to weight ratio in excess of 10,000:1. They operate

within milliseconds of receiving the appropriate

electrical impulse. The devices are hermetically sealed and are maintenance free. maintenance free. A

monitoring current of maximum 0.01 Amps is sufficient

to show that the device is still operational.

Specifications

Minimum Work Output 10 Joules

Minimum Peak Thrust 2276 Newtons

Minimum Piston Stroke Length 13.64 mm

Shelf Life (ambient) 10 years

Operating Temperature - 40°C to 84°C

Can withstand short periods at - 46°C to

125°C

Nominal Input Energy 6 millijoules

Resistance Range 0.9-1.6 Ohms

Max No Fire Current:

30 sec Pulse: 0.15A

0.050 sec Pulse: 0.3A

Min Single Fire Current:

DC: 0.6A

10ms Pulse: 0.9A

Recommended Single Firing

Current 1A

Recommended Series Firing

Current 3A

DR2094 Metron Actuator

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 22: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Description The hot gaseous products of the electrically initiated

combustion reactions expand extremely rapidly and are vented, from the brass body of the generator, through end ports. By suitable design of the recipient chamber this

expansion can be used to do mechanical work. The ability to operate from small electrical impulses, their compact size and high reliability make these

devices suitable for automatic or controlled applications such as :

-Driving cutter blades to burst sealing discs, etc.

-Opening Valves -Pushing Loads -Wing Unfolding Mechanisms

-Fin Lock Mechanisms

Metron Gas Generators are single shot

devices for generating very high pressure in

small confined spaces.

Gas Generators Chemring Energetics UK Ltd has designed and

manufactured several variations of the basic device with its specialised design and development facilities.

Chemring Energetics UK Ltd is approved for designing to NATO Standard AQAP-1.

It should be noted that ignition of fusehead composition does not necessarily result in the wire being broken and it is possible that after operation

Metron Actuators may register a resistance.

Characteristics Some typical values are not necessarily minimum values.

When designing applications, users should ensure that adequate safety margins on thrust etc. are applied as normal engineering practice. A Chemring Energetics

UK Ltd technical representative should be consulted

prior to using this data as a specification.

Insulation Before firing an insulation of not less than 100

megaohms at 100v DC exists between the shunted

leads and body of the device.

Electrostatic Sensitivity Metron Actuators will withstand a discharge of 300pf at

5kV minimum between the shunted leads and the body of the device.

Device Function Time The function times of the actuators vary with current

applied. Typical values may be 10-20 milliseconds.

Electric Characteristics

Nominal Energy 6 millijoules

Resistance Range (ohms)(1): 0.9-1.6

Max No Fire Current (2)

30 sec pulse: 0.15A

0.050 sec pulse: 0.3A

Min Single Fire Current (3)

DC: 0.6A

10ms pulse: 0.9A

Recommended Single Firing Current 1A

Recommended Series Firing Current

(4) 3A

Max Monitoring Current 0.01A

(1) The completed device resistance depends on cable

type. (2) The fusehead may be desensitised by being subjected to currents between the maximum

recommended monitoring test current and the No Fire Current (inclusive) and is not guaranteed to fire

afterwards (3) This is the recommended current to initiate one

actuator in the circuit (4) This is the recommended current to initiate more than one actuator in series in a circuit. It should be

applied for a minimum of 10milliseconds. When designing series firing systems a Chemring Energetics UK Ltd technical representative should be consulted.

DR4000 Series Gas Generators

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 23: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Metron Actuators are single shot devices

which rapidly convert small electrical

signals into useful mechanical work output.

High Power Actuators have been

developed for applications where

increased power and/ or increased

temperature range is required.

Description

High Power Actuators can be designed to

incorporate an ignition system, designated as

DR1000/SA/7, capable of withstanding, without

firing, an applied pulse of one amp one watt for

five minutes. The Igniter has been characterized

according to an approved UK Defence Ordnance

Safety Group method and reported in

DMP11773.

Shipping

Our standard range of Metron Actuators are

classified as non Explosive and are exempt from

UN class 1. In the approved pack Metron

Actuators can be shipped through normal parcel

post .

Example Specifications

Bridge Resistance: 0.65 - 0.9 ohms

All Fire: 3.5 amps (50ms pulse)

No Fire: 1 amp 1 watt 5 mins

Lead Length: 93mm max

Piston Stroke: 10mm (nominal)

Output Energy: 12.0J min

Peak Thrust: 4000N (typical)

End Thrust: 1000N (typical)

Monitoring/ Test

Current: 10mA max

Ignition Material: Barium Styphnate

Propellant: Blackpowder

NEQ: <100mg

Operating Time: 15ms max at 3.5 amps

Operating Temperature: -40oC to +125oC

Life: 10 years at 21oC

Reliability: 0.999 at 95%

confidence

High Power Actuators

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 24: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Igniters

Chemring Energetics UK Ltd has a long

established expertise in the design, development

and manufacture of igniters.

The igniters are self-contained and are, most

commonly, electrically activated.

Igniters are developed to meet customer specific

requirements with regards to the input activation

characteristics and the output, together with the

enclosing hardware.

Most Igniters are supplied hermetically sealed.

Fuzeheads

Fuzeheads form the basis of many stores where

reliable initiation of pyrotechnic compositions,

propellant trains or explosive trains is required.

A range of Fuzeheads is offered with varying

operational characteristics and all Fuzeheads can

be supplied with lead wires attached.

Activation

Igniters can be either electrically or percussion

operated.

A range of electrical sensitivities is offered up to the

recognised 1A1W no fire condition pressures.

Typical Application

Igniters have a wide variety of uses which include,

for example:

- Ignition of liquid monofuels and fuel driven

turbines in missile propulsion units

- Igniting monofuel driven turbines in underwater

applications

- Ignition of solid propellants in gas generators,

rocket motors and cartridges

Ballistic Outputs

Igniters are fabricated from Chemring Energetics

proven range of extruded propellants and MoD

approved pyrotechnic pressed powders. Individual

devices have operation times in the range 3msec to

10secs.

FH1 FH2 FH3 FH4 SA/25

Resistance (Ω) 0.9 - 1.6 0.15 - 0.3 10 - 16 8 - 20 1.3 - 2.2

Typical all fire current (A) 0.9 4 0.145 0.085 1

Current application time

(m/s) 10 10 10 15 10

Max no fire current (A) 0.3 0.9 0.05 0.025 N/A

Max monitoring current

(mA) 10 10 10 10 10

Body length (mm) TYP 6 TYP 6 TYP 6 TYP 6 TYP 6

Body width with GMS (mm) 5 5 5 5 6

Specification GW MIL 364 GW MIL 364 GW MIL 364 GW MIL 364 N/A

Igniters & Fuzeheads

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Apr 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 25: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

1. Instruction Scope

2. Actuator Characteristics

1.1 This user instruction document provides information on the product characteristics, handling, and instal-

lation of the following variants of Metron Actuators:

DR2000 Series: Protractors;

DR3000 Series: Retractors; and DR5000 Series: Guillotines.

1.2 All information is intended for guidance only. Recipients should satisfy themselves with the suitability of

the Metron Actuator for their particular purpose.

2.1 Metron Actuators are category P1 pyrotechnic articles.

2.2 Metron Actuators are available with varying electrical sensitivity and performance characteristics such as

force, energy, function time, and piston stroke length. The user must be satisfied that the correct part

number, as recommended by the valve/system manufacturer, is fitted. 2.3 The method of ignition for Metron Actuators is by electrically initiation. The electrical characteristics of

articles can be found in the relevant Product Specification Data Sheet.

2.4 Electrical initiation of a Metron Actuator will result in the movement of a piston to perform mechanical

work.

2.5 Initiation of DR2000 series protractors will result in a small metal septum being ejected from the front of

the device, and a piston will project at a high velocity up to a maximum of 20mm in length (Fig 1). The

septum will decelerate quickly due to its weight, and will typically travel up to 30 centimeters if unobstructed.

FIG 1

Protractor As Received Piston projected following initiation

2.6 Initiation of DR3000 series Retractors will result in the protruding piston retracting into the body at high

velocity. 2.7 Initiation of DR5000 Guillotines will result in the piston cutting blade moving at a high velocity to shear

User Instructions - Guide 39

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Nov 2015

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 26: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

3. Linking and Arrays of Metron Actuator

4. Installation Guidelines

5. Product Safety, Storage and Disposal

3.1 Metron Actuators may be linked to form an array for some applications.

3.2 CEUK recommend series firing as being the simplest and most reliability method to fire multiple Metron Actuators simultaneously. It is critical that only Metron Actuators of the same electrical sensitivity are

linked in a multiple firing circuit. 3.3 It is recommended that users contact CEUK if planning on using a multiple firing circuit. Additional

information on series firings may be sought from Guide-88.

Metron Actuators are used in a wide range of applications and, as such, installation procedures are largely

governed by customers systems. The following installation, monitoring and handling guidance should be observed:

4.1 Metron Actuators must be fitted in strict compliance with the valve / system manufacturers’ instructions.

4.2 Some actuators are fitted with a hexagonal end cap, and care must be taken to ensure that no movement occurs at the end cap relative to the body. Actuators should be installed tight by hand force, and use of a

wrench avoided during installation/removal. Movement of the end cap relative to the body may render the

actuator inoperable.

4.3 Care must be taken to ensure that the actuator cable/lead wires do not twist or flex relative to the actuator during installation. The lead wires are fragile and can be easily damaged due to twisting/flexing.

N.B. this does not refer to Metron Actuators which are supplied with twisted cables as part of the cable finish.

4.4 Electrical test meters and monitoring circuits must be limited to 0.01 Amps short circuit current to prevent inadvertent operation of the Metron Actuator. Unless otherwise stated by CEUK, this

monitoring current level must not be exceeded.

5.1 Users should refer to the Product Safety Data Sheet, PSDS-67, for relevant information on hazards,

toxicity, storage, and disposal of Metron Actuators.

5.2 The actuator should be replaced at intervals as instructed by the valve/system manufacturer, depending on service conditions. Metron Actuators have a maximum total life of 11 years from date of manufacture,

consisting of 1 year shelf life, and 10 years’ service life at standard ambient conditions. More arduous environments may require more frequent replacement. The date of manufacture can be found on the

article and/or packing label.

User Instructions - Guide 39

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Nov 2015

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 27: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

7. Contact

Chemring Energetics UK Ltd.

Ardeer Site,

Stevenston,

Ayrshire,

Scotland

KA20 3LN

Phone Number: +44 (0)1294 487007 Fax Number: +44 (0)1294 487280

Emergency Phone Number (24 Hour): +44 (0)1294 461000

6. Additional Information

Additional information on performance and safety can be sought from the relevant Product Specification Data

Sheet, Product Safety Data Sheet, and other technical guidance documents referred to within this user instruc-

tion.

Chemring Energetics UK Ltd should be contacted if additional information is required.

User Instructions - Guide 39

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 Nov 2015

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 28: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Product: Metron Actuators

DR3000 Series: Retractors DR5000 Series: Guillotines

Intended Use: To provide mechanical movement from a small electrical impulse. Manufacture: Chemring Energetics UK Ltd. Ardeer Site,

Stevenston, Ayrshire, Scotland

KA20 3LN

Phone Number: +44 (0)1294 487007 Fax Number: +44 (0)1294 487280

Emergency Phone Number (24 Hour): +44 (0)1294 461000 Email: [email protected]

1. Identification of Product and the Company

2. Hazards Identification

This product is classified as an Article under REACH [1] and is therefore not subject to the requirements for

provision of safety information as defined in EU1907/2006, Article II. While this product may release hazardous

substances, if damaged through improper use, this is not an intended release as defined under REACH.

This data sheet does not provide information on user application but is intended to give suitable information on the hazards posed by the product in its packaged and unpackaged state. The dismantling of this article is prohibited. This article contains hazardous substances not intended to be released

under normal or reasonably foreseeable conditions of use. The Metron Actuator (DR2000 Series) is classed as a P1 pyrotechnic article and is presented as a hermetically sealed

unit with an energetic content of no greater than 100mg.

3. Composition/ information on Ingredients

Product description: The Metron Actuator is a sealed device (cylindrical metal housing with protruding wires)

with no exposure anticipated to the chemical compositions, sealed within, under normal storage, handling and use. Metron Actuators contain a single, or a mixture of energetic compositions. In all instances the maximum mass of

composition within the device is 100mg.

The following compositions may be found in a Metron Actuator, with a maximum mass offered for reference only: Black Powder (potassium Nitrate) ≤ 80mg

Nitrocellulose ≤ 20mg Lead di-nitroresorcinate ≤ 30mg Barium Styphnate ≤ 22mg

Lead Styphnate ≤ 15mg Red Lead ≤ 10mg Silicon ≤ 10mg

Chemring energetics UK Ltd should be consulted for further information on the composition(s) contained within specific products where required

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 29: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

4. First Aid Measures

Normal exposure: Product design (materials sealed inside the device) prevents contact with explosive materials in

normal use. In the unlikely event of exposure to materials inside the device:

Eye Contact: Rinse/flush eyes with water for at least 10 minutes. Remove contact lenses if worn. If

irritation persists, repeat the flushing process. In all cases of eye contamination it is a sensible precaution to seek medical advice.

If an eye is struck by the septum or piston seek immediate medical attention.

Skin Contact: Wash affected area with mild soap and water. Remove any contaminated clothing. If

irritation occurs seek medical advice.

Inhalation: Remove to fresh air. Seek medical advice if symptoms persist.

Ingestion: Do not induce vomiting or give anything by mouth. Seek medical advice. Medical attention and special treatment: Treat symptomatically.

5. Fire Fighting Measures

If safe to do so, use large quantities of water to control/extinguish any fires.

Fire fighters must be made aware of the potential of the device functioning following exposure to heat. Projectiles may result.

Combustion products are toxic (oxides of lead, oxides of carbon and oxides of nitrogen) should they be released from the device. Self-contained breathing apparatus should be worn.

6. Accidental Release Measures (Spillages)

All accidental spillages should be addressed after risk assessment and in accordance with a safe system of work.

Any spillage of articles should involve careful recovery of the articles before placing them into an appropriately labelled and sealed container. Recovery personnel should wear safety glasses and ensure the device is angled away from the face and body. Electrostatic precautions are recommended.

Spillage of substances from Metron Actuators is considered unlikely as the substances are enclosed within sealed units. In the unlikely event that explosive compositions do spill from the article evacuate the immediate area. Take care to cordon off the affected area and avoid walking on or dragging equipment across. Seek assistance on clean-up

and disposal from suitably qualified and experienced personnel.

7. Handling and Storage

Conditions for safe storage:

CEUK recommends that devices should be stored in an appropriately licensed location and within the packaging supplied until required for use. Dry, temperate storage conditions (Min 5oC, Max 25oC), are recommended. When stored under the above conditions, the recommended life for the article is 10 years.

It is recommended that the packaged devices should be securely stored and away from sources of heat. Local regulations may apply.

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 30: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Precautions for safe handling:

Not to be handled by persons under the age of 18 years. Do not handle until all installation and safety precautions are read and understood.

Do not attempt to open or disassemble the device. Handle devices with care, avoiding exposure to heat, flame, impact and stray currents, including electrostatic

discharge. Devices should be pointed away from personnel during handling operation.

8. Exposure Controls/ Personal Protection

Exposure Limits: The following occupational exposure limits are provided for information only. No exposure to

the components of the Metron Actuators should occur during normal use.

Substance Limit

Black Powder (Potassium Nitrate) 4mg/m3, 8 hour TWA (Respirable Dust)

Nitrocellulose No Occupational Exposure Limit Values Available

Lead Styphnate 0.15 mg/m3 (8 hour TWA as Lead)

Lead Di-nitroresorcinate 0.15 mg/m3 (8 hour TWA as Lead)

Red Lead 0.15 mg/m3 (8 hour TWA as Lead)

Silicon 10mg/m3, 8 hour TWA

Barium Styphnate 0.5mg/m3 (8 hour TWA as Ba)

Personal Protective Equipment:

Respiratory Protection: Not applicable for normal use. Work in well ventilated area.

Should users be exposed to substances, post-combustion fumes will contain lead, carbon and oxides of carbon and nitrogen.

Hand Protection: Not applicable in normal use.

Eye Protection: Safety glasses recommended.

Skin Protection: Not applicable, but take precautions to keep device pointed away from personnel during handling.

General: Protective clothing and equipment compliant with local regulations for use with explosives are recommended.

9. Physical and Chemical Properties

A cylindrical metallic housing – typically brass or steel – with protruding cables which may include connector

terminals. Auto ignition temperature is ≥ 170°C.

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 31: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

10. Stability and Reactivity

11. Toxicity Data

Stability: Stable under recommended storage and handling conditions.

Materials to Avoid: Avoid exposure to corrosive materials.

Conditions to Avoid: Heat, fire, elevated temperatures, any source of electrical power, incendiary sparks, shock, impact, friction, electrostatic sparks and discharges.

Hazardous Decomposition Products: In normal operation the combustion gases are retained within the device.

The following toxicological data is provided for information only. No exposure to the components of the Metron

Actuators should occur during normal use.

Substance CAS No LD50 Warning

Symbols

GHS Hazard statement

'H' codes

Lead Styphnate

(RD1349)

15245-44-0 No Data Available GHS01, GHS07,

GHS08, GHS09.

H201, H302, H332, H360Df,

H373, H400, H410.

Lead

Dinitroresorcinate (RD1337)

13406-89-8 No Data Available GHS01, GHS07,

GHS08, GHS09.

H200, H302, H332, H360,

H373, H400, H410.

Potassium Nitrate 7757-79-1 3,750mg/kg (Oral Rat) Experience with humans suggests danger of methaemoglobinaemia

GHS03, GHS07. H272, H315, H319, H335.

Barium Styphnate

(RD1320)

20236-55-9 No Data Available GHS01, GHS02,

GHS07.

H201, H261, H315, H319,

H335.

Red Lead 1314-41-6 630mg/kg

(Rat, Intraperitoneal)

GHS03, GHS07,

GHS08, GHS09.

H272, H302, H332, H351,

H360, H372, H410

Silicon 7440-21-3 3,160 mg/kg (Rat, Oral) GHS02 H228

Nitrocellulose 9004-70-0 No Data Available GHS01, GHS02. H201, H228.

See Section 17 for further explanation of warning symbols and hazard statements

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 32: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

12. Ecological Data

13. Disposal

The following ecological data is provided for information only. No exposure to the components of the Metron Actu-

ators should occur during normal use.

Substance CAS No Ecological Information

Lead Styphnate 15245-44-0 No data available on this substance. Individual constituents are as fol-

lows: Lead: Very toxic to aquatic organisms. (The LC 50 of lead (48 hrs.) to bluegill (Lepomis macrochirus) is reported to be 2-5mg/l)

Lead

Di-nitroresorcinate

13406-89-8 No data available on this substance. Individual constituents are as fol-

lows: Lead: Very toxic to aquatic organisms. (The LC 50 of lead (48 hrs.) to

bluegill (Lepomis macrochirus) is reported to be 2-5mg/l)

Potassium Nitrate 7757-79-1 May cause Algae bloom. Do not allow to enter watercourse. LC50, 96

Hrs, Fish 1378 mg/l

Barium Styphnate

(RD1320)

20236-55-9 No data available.

Red Lead 1314-41-6 Very toxic to aquatic life with long lasting effects.

Silicon 7440-21-3 No data available.

Nitrocellulose 9004-70-0 No known long term negative effects on the environment. LC50

>1000mg/l.

Product Disposal:

Reference should be made to authoritative guidance for the disposal of explosives and explosives articles [1]. Local regulations may apply.

This product should only be disposed of by competent persons following a prescribed safe method. Precautions

should include protection of personnel against blast, heat, flame, fragmentation and noise.

Further advice on the handling and disposal of damaged or unwanted product should be obtained from Chemring Energetics UK Ltd.

Packaging Disposal: Ensure all packages and packing materials are free from explosives prior to disposal.

14. Transportation

The Competent Authority of a Contracting Party to the European Agreement Concerning the International Carriage

of Dangerous Goods by Road (ADR [3]) has excluded Metron Actuators (DR2000, DR3000 and DR5000) from Class 1, for transport, and designated as not presenting a significant hazard from explosion. Metron Actuators are included by name in the UK List of Classified Explosives and Fireworks and listed as outside Class 1.

There are no restrictions on transport by road, rail, sea, inland waterway or air.

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 33: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

15. Regulatory Information

16. Other Information

This product is subject to the provisions of the following legislation:

The Explosives Regulations 2014 [4]

ADR European Agreement Concerning the International Carriage by Dangerous Goods by Road [3]

The following devices conform to the requirements of Directive 2013/29/EU, are categorised as type “Pyromechanical devices, Actuator”, are categorised as P1 and are marked with the CE mark [5]:

DR2003 DR2004 DR2005 DR2006 DR2014 DR2024 DR2027

DR2028 DR2032 DR2053 DR2057 DR2069 DR2074 DR2075

DR2076 DR2077 DR2082 DR2084 DR2085 DR2089 DR2094

Information for installation of Metron Actuators can be sought from CEUK Guide-39 [6].

Performance data on specific Metron Actuators can be sought from the relevant product specification data sheet.

Guidance on hazard phrases:

H Phrase Text

H200 Unstable explosive

H201 Explosive: mass explosion hazard

H228 Flammable solid

H261 In contact with water releases flammable gas

H272 May intensify fire: oxidizer

H302 Harmful if swallowed

H315 Causes skin irritation

H319 Causes serious eye irritation

H332 Harmful if inhaled

H335 May cause respiratory irritation

H351 Suspected of causing cancer

H360 May damage fertility or unborn child

H372 Causes damage to organs through prolonged or repeated exposure

H373 May cause damage to organs through prolonged or repeated exposure

H400 Very toxic to aquatic life

H410 Very toxic to aquatic life with long lasting effects

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.

Page 34: Metron Actuators - Chemring Energetics/media/Files/C... · In multiple firing circuits all actuators must be of the same electrical ... for a single actuator of the same ... Metron

Guidance on hazard phrases

Warning

Symbols

GHS

Pictogram

Warning

Symbols

GHS Pictogram Warning

Symbols

GHS Pictogram

GHS01

GHS02

GHS03

Explosive Flammable Oxidising

GHS07

GHS08

GHS09

Health hazard/

Hazardous to the ozone layer

Serious health

hazard

Hazardous to the

environment

The technical information provided in this Product Safety Data Sheet should only be used for the purposes of

identifying hazards with respect to safety of personnel and the environment in storage and handling. It should not be used as a technical specification or for engineering calculations.

The information in this document is believed to be accurate and is given in good faith, but it is for the customer to satisfy itself of the suitability for its own particular purpose. The information provided is intended to describe the

product for the purposes of health and safety and environmental requirements only. It is not intended and should not be construed as a warranty. Chemring Energetics UK Ltd should be consulted for further information.

17. References

[1] Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), European Regulation EC

1907/2006

[2] CBI-EIG, Guidance for the Safe Management of the Disposal of Explosives

[3] ADR European Agreement Concerning the International Carriage by of Dangerous Goods by Road, IBSN

978-92-1-139131-2.

[4] Explosives Regulations 2014, Statutory Instrument 2014 No.1638

[5] Directive 2013/29/EU on the harmonisation of the laws of the Member States relating to making available

on the market of pyrotechnic articles (recast)

[6] CEUK Guide-39, Use instructions for Metron Actuators

Product Safety Datasheet - 67

Energetic Systems

Approved to ISO 9001 I ISO 14001 I OHSAS 18001 I Part of the Chemring Group Issue 1 May 2016

Content of this datasheet is subject to modification without prior notice. It does not constitute a Technical Specification.