MEDICAL SOLENIODVALVES

> Revolutionary design uses an all-plastic bobbin core as the sleeve, simplifying its manufacture, providing a low cost, high quality part.> The � nished assembly is over molded with Dupont® Rynite®.> Applications include laboratory equipment and media analysis devices. > 1/8” NPT with a plastic body.

> Kalrez®, Hyphlon®, Neoprene®, Nylon, Te� on®, Urethane®, FKM®, KEL-F®, Santoprene®, Nitrile, Nordel, Silicone, Buna and others available.

Diode Rectifi ed Coil Valve

Magnet Latching

Plastic Valves

Seal Material Options

Features Available:

> Small and compact valves for small spaces.

> Lightweight valves when portability is a need.

> Quiet and smooth operation.

> Low power and energy consumption provides e� ciency and a reduces environmental footprint.

> Wide variety of voltages are available suiting di� erent applications.

> Several seal materials that accommodate di� erent media.

> Large variety of coil electrical connections available.

> Stacking multifunction valves (up to 10 stations) is easy due to PeterPaul’s design and extremely cost e� ective.

> Valves are available in aluminum, stainless steel, brass and plastic.

> The simple manifold mount allows for many di� erent applications based on the number of valves needed. 

> A welded body to the sleeve and the weld in tubes for port connections providing leak-proof and cleanliness.

> Power ranges as low as .5 to 18 watts.

> Ori� ce sizes available from .6 mil - 3” to accommodate nearly any � ow requirement.

> 10-32 ports or manifold mount

> Type of ports: NPT, UNF, BSPT and SAE

> Total temperature range: (Class A, non-molded coil rated at 105 degrees C) (Class F, molded coil rated at 155 degrees C) (Class H, molded coil rated 180 degrees C)

> Certi� cations: U.L., CSA, NSF

> Advanced electronic design technology has led to production of these AC input, DC operation valves.> Quiet, “no click” performance, and cooler running temperatures, they are used extensively where noise and heat are undesirable.> Available in all valves.

> Low-power design for medical environ- ments where power is limited or continuous power application causes unwanted coil heat. > External latching component adapts to to any Series 20, 30 or 80 valve.  > Single encapsulated coil/magnet assembly, brass body, and an integral Form “A“ DIN connection.> Standard in 6, 12, 24, and 28 volts DC. Other voltages available.

> Applications include laboratory analysis equipment.> Design of stacking valve bodies for Series 15/50 valves calls for a passivated stainless steel or aluminum body.> Common in, common out, 2-way and 3-way versions available.

Stacking Valves

Welded Tubes & Fittings

Manifolds

Submersible Valves

Vacuum Valves

> Uses include vacuum chambers for sterilization.> Feature high � ows, bubble tight standard vacuum � ttings, and standard � anges for international use, and where purity requirements allow no trapped particles on the inner diameter.

> Up to 5000 PSI.

> Kel-F pin sealing element.

> Ori� ce guides the sealing pin for perfect alignment.

> Simple construction… only three moving parts.

High Pressure Valves

> Applications include laboratory analysis equipment.

> Designed for applications where the valve can be completely submerged. > Water-resistant for immersible or wetted equipment and submerged operations.> 2 and 3-way valves available with 1 or 2 lead wires.

> Custom integration of components based on customer requirements.

> Unlimited interface options for media, power, and components.

> Designed to meet stringent purity requirements in analysis equip- ment and other applications requiring all welded components.> Available with various options including 3-way operation and diode recti� er coils for quiet operation.> Continuous operation at maximum rated pressure.

For more information contact us at 1-860-229-4884 >>> www.peterpaul.com

> Custom integration of components based on customer requirements.

> Unlimited interface options for media, power, and components.

APPLICATIONS

Opportunity: Develop a reliable and leak free high pressure unit for Argon, Helium, Nitrous Oxide and other medias in cryoablation applications with a small footprint.Solution: Design a four station manifold to remove leak points by eliminating plumbing.Applied Application: Used to control the � ow of high pressure gas into syringes for cryoablation surgery where gas is used to freeze cancer cells. Bene� t 1: PeterPaul valve allows the HPE process to yield pure dry hydrogen.Bene� t 2: By pressurizing the hydrogen in the electrolyzer, the need for an external high pressure compressor is eliminated.Bene� t 3: Reduces assembly costs. Aesthetically more appealing and more organized system, that includes a desiccant drying system as well as controlling the delivery with solenoid valves.

Opportunity: Develop cost e� ective valve to deliver high � ow air while hitting high life cycle requirements and low power consumption. Solution: Valve designed with unique combination of square plunger, low watt coil and barbed body. Applied Application: Used � ow air to a DVT cu� system.Bene� t 1: Met smaller footprint than other available products. Bene� t 2: Reduced assembly costs while hitting hit target � ow and lifecycle metrics.

Opportunity: Develop a high pressure, high temperature and chemical resistant unit for a sterilization system. Unit to be used in various countries with a wide range of voltages requirements.Solution: Two way normally closed valve with special A� as seals for temperature and chemical compatibility. High heat (220°C) coil with full wave bridge recti� cation. High temperature coil insulation system components to handle high ambient and media temperatures as well as the self heating from a high wattage coil.Applied Application: Used to sterilize medical equipment with steam.Bene� t 1: High � ow design which enables very fast sterilization cycles.Bene� t 2: Wide voltage input capability to allow usage in many countries around the world.Bene� t 3: Reasonably small foot print for � ow capability which allows for easier sterilization packaging.

EXAMPLE

1

EXAMPLE

2

EXAMPLE

3

PeterPaul, World Headquarters480 John Downey Drive, New Britain, CT 06050-1180

860.229.4884 860.223.1734 www.peterpaul.com

EXCELLENCE BY CONTROL

PeterPaul, Latin American HeadquartersAvenida Michael Mangiafico, Puerto Real Industrial Park, Puerto Real, PR 00740

787.863.3085 787.863.4200www.peterpaulelectric.com