mcc software installation manualalbanydoors-helpme.de/_hilfe/steuerungen/2_neu/mcc/mcc... · 2020....

19
MCC Software Installation Manual MCC Software installation manual EN_06.docx 1 08.07.20 MCC Software installation manual

Upload: others

Post on 28-Jan-2021

37 views

Category:

Documents


0 download

TRANSCRIPT

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 1 08.07.20

    MCC Software installation manual

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 2 08.07.20

    Contents 1 Connection computer MCC ................................................................................. 3

    1.1 Item numbers ............................................................................................................. 3

    1.2 Jumper setting at the Dongle ..................................................................................... 4

    1.2.1 Version 1 ..................................................................................................................... 4

    1.2.1 Version 2 ..................................................................................................................... 5

    2 Installation of the software ........................................................................................ 6

    3 Additional functions ................................................................................................. 15

    3.1 Request of the in- and outputs ................................................................................. 15

    4 Troubleshooting ....................................................................................................... 17

    4.1 The Toolbox doesn’t start ......................................................................................... 17

    4.2 The „Code status“ doesn’t change from red to green after the code input ............. 17

    4.3 The window „’XXXX-XX-XX‘ is not a valid date.“ pops up again and again ............... 18

    4.4 No data connection to the MCC possible ................................................................. 18

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 3 08.07.20

    1 Connection computer MCC

    Connect the connection cable (USB A) from the dongle with a free USB port of your PC. The other connector (USB-B) is plugged in the dongle. The Y-adapter cable (9-pol.) SUB-D-plug) should be connect to the dongle. Unscrew the display cable at the display and connect the plug of the adapter cable with the M12 plug. This can be done also under power. If necessary the display can be connected to additional M12 connector of the adapter cable. Due to the used plug, an incorrect connection is excluded.

    Caution when using display and PC together sometimes the display function is slow!

    Depending on the operating system of the connected computer, the drivers for the dongle must be installed manually. It is recommended to update to the latest version from the Internet.

    1.1 Item numbers

    Dongle with USB cable => 4920V0025

    Y-Adapter cable => 4920R0037

    Computer

    Dongle

    Display

    Y-Adapter cable

    Display cable from MCC

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 4 08.07.20

    1.2 Jumper setting at the Dongle

    1.2.1 Version 1

    Jumpereinstellungen:

    1-2 connected

    3-4 not connected

    5-6 connected

    7-8 connected

    9-10 not connected

    11-12 connected

    13-14 not connected

    15-16 connected

    17-18 not connected

    19-20 connected

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 5 08.07.20

    1.2.1 Version 2

    Jumper settings JP2 (from left to right):

    JP1 (white) 1-2 connected

    JP2 (red) 5-6 connected

    JP3 (white) 8-9 connected

    JP4 (green) 11-12 connected

    JP5 (yellow) 14-15 connected

    JP6 (red) 17-18 connected

    JP7 (green) 20-21 connected

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 6 08.07.20

    DIP-switch SW1:

    1 Off

    2 Off

    3 Off

    2 Installation of the software

    System requirement: min. Windows XP

    The Toolbox requires english Date format (JJJJ-MM-DD)! Troubleshooting see chapter 4.3

    To install the software connect the computer to the MCC as described in the chapter 1. The dongle should be coded as described in section 1.2.

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 7 08.07.20

    Depending on the used Windows version and setup, it may block the download of the software. The following message appears

    To do this, click the "More info" selection and press "Run anyway" in the window that opens. The file will be downloaded directly.

    To install the software package start the file "MCC release X_XX.exe" (XX stands for the current software version, e.g. "MCC release 2_3_672_R.exe").

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 8 08.07.20

    Click "Next" and select the desired directory path, e.g. "C:\Users/…/MCC".

    Click "Next" again to continue the installation.

    During the installation, a shortcut symbol is created on the screen. Doubleclick the

    shortcut to start the programm.

    Toolbox

    Expert

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 9 08.07.20

    Click the button "Set access code" to enter the code.

    Enter the provided "User code" and "Access code" in the appropriate fields.

    After the activation is done automatically the window changes as follows.

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 10 08.07.20

    Save the code with the button "Save". The previous menu appears again. Enter the user code again and confirm with ENTER or OK.

    After the activation, the following window appears automatically:

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 11 08.07.20

    Now, the interface must be selected from the computer. In the menu bar under the item "Settings" select the "serial port" marked with MCC. In this example, e.g. "COM7". “Auto-connect” needs to be selected.

    The installation is now complete and you can select the desired configuration file (config).

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 12 08.07.20

    For safety reasons the selected config file with the doortype will be shown again. If this is correct it can be confirmed with the "OK"button.

    The upload is started by pressing the button "Update MCC".

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 13 08.07.20

    Then appears a short warning message that the existing file on the MCC will be overwrited. This is confirmed with the "OK"button.

    Now it follows a note which software parts will be upload or updated.

    WARNING

    During the update of the boot software the power of the MCC shoulds not turned off!

    After activation of the "OK" button, the process will start automatically.

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 14 08.07.20

    After successful completion the following text "MCC system start and ok" appears in the bottom window status display.

    After the update the service counter should be reset "Restart service period".

    The softwareupdate or the softwareupload of the new config is now finished.

    A full description of the software can be viewed in the menu bar under "Help", or by pressing the F1 key.

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 15 08.07.20

    3 Additional functions

    3.1 Request of the in- and outputs

    The state of the in- and outputs from the power and assembled MCC can be checked with the "Status" button. Green dot means 24 V power and red dot means 0 V. To display the right values of the config please download the config before checking.

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 16 08.07.20

    At the same time the programmed function of inputs and outputs can be read. E.g. X 15 = > input = Up auto frontside, output = Traffic light green frontside

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 17 08.07.20

    4 Troubleshooting

    4.1 The Toolbox doesn’t start

    Each Toolbox version has got a fixed time stipulated periode of use.

    After the expiration date, the software version is invalid and can no longer be used with the old code! Each registered Toolbox user gets together with the new code automatically in due time before the expiry of the old version via email a link to download the new software. If there no new version of the software, only a new access code will be sent. The old code can no longer used.

    4.2 The „Code status“ doesn’t change from red to green after the code input

    Is the latest version of the software installed? The new code works not for old versions but only for the current!

    Download and install current software version

    The „User code“has been entered incorrectly

    Please compare the spelling with the E-mail. Enter the "User Code" in lowercase (possibly operated caps-lock button note!)

    During the initial installation of the Toolbox, it can happen that the first code is not accepted.

    After entering the first code and pressing the ENTER key delete the code and enter the second code from the E-mail.

    Validity date, here till 2020-12-31

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 18 08.07.20

    4.3 The window „’XXXX-XX-XX‘ is not a valid date.“ pops up again and again

    The set date format is incorrect!

    Exit the Toolbox in the task manager of Windows and change the date format in Control Panel ("Regional and Language Options") to the date format "YYYY-MM-DD". Then start the Toolbox and enter the code again.

    4.4 No data connection to the MCC possible

    An existing data connection will be shown in the Toolbox window as a green dotted line. Due disconnect connection the line is missing.

    An disconnected or interrupted connection can have the following reasons::

    - The cables and plugs are not corrected in the right way.

    - The MCC control unit is turned off

    Existing data connection

  • MCC Software Installation Manual

    MCC Software installation manual EN_06.docx 19 08.07.20

    - The jumper in the dongle are not adjusted in the right way (see chapter 1.2)

    - Install if necessary the driver of the dongle manually.

    - A wrong interface connection is selected (Toolbox => Settings => Serial port => select COM-Interface with MCC in brackets behind).

    - At Toolbox => Settings => At „Modbus/Bluetooth adapter“ no hook should be set!

    - At Toolbox => Settings => At „Auto connect“ a hook should be set!