manual ph metru

14
Edition 10/10 Manual de Operare Transmițători de măsurare inteligenți pentru pH, redox (ORP), ISE, conductivitate, oxigen, clor MV 4010 MV 4015 MV 4016 MV 4020 MV 4025 MV 4030 MV 4060 Sensortechnik Meinsberg GmbH Quality System certified to DIN EN ISO Kurt-Schwabe-Straße 6 D-04720 Ziegra-Knobelsdorf/Gemany Internet: www.meinsberg.de Tel.: +49 34327 623-0 Fax: +49 34327 623-79

Upload: rykko-cryss

Post on 28-Dec-2015

66 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Manual Ph Metru

Edition 10/10

Manual de Operare

Transmițători de măsurare inteligenți

pentru pH, redox (ORP), ISE, conductivitate, oxigen, clor

MV 4010

MV 4015

MV 4016

MV 4020

MV 4025

MV 4030

MV 4060

Sensortechnik Meinsberg GmbH Quality System certified to DIN EN ISO

Kurt-Schwabe-Straße 6 D-04720 Ziegra-Knobelsdorf/Gemany

Internet: www.meinsberg.de Tel.: +49 34327 623-0 Fax: +49 34327 623-79

Page 2: Manual Ph Metru

1.

2.

3.

PREZENTARE......................................................................................................................3

Siguranta..............................................................................................................................3

Conexiunile Terminalului, Instructiuni de Operare pe scurt, Ajustarea di Fabrica.......4

Diagrame de conectare a senzorilor..................................................................................6

Senzor de Temperatura................................................................................................................. 6

pH/redox (ORP) si Electrozi Ion-Selectivi (ISE) ........................................................................ 7

Celula de masurare Conductivitate, Senzori de Oxigen si Clor................................................. 8

CALIBRARE DIN BUTOANE ...............................................................................................9

Calibrare Transmitator de pH (Transmitator ISE) ................................................................... 9

Calibrare Transmitator de Conductivitate .................................................................................11

Calibrare Transmitator Oxigen ...................................................................................................12

Calibrare Transmitator Redox (ORP).........................................................................................12

Calibrare Transmitator Clor........................................................................................................12

SOFTWARE PC „DINMODULE“ ........................................................................................13

Instalarea și punerea în lucru........................................................................................................13

Masurare On-line...........................................................................................................................14

Configurare.....................................................................................................................................14

Calibrare.........................................................................................................................................16

Conectarea mai multor emițătoare la o rețea (INSTRUMENTATIE MULTI-PARAMETRU) .........................................................................................................18

SOFTWARE / FIRMWARE UPDATE...................................................................................18

ÎNTREȚINERE, ELIMINAREA .............................................................................................19

ÎNTREȚINERE Sensor / Electrode .............................................................................................19

Disposal............................................................................................................................................19

4.

4.1

4.2

4.3

5.

5.1

5.2

5.3

5.4

5.5

6.

6.1

6.2

6.3

6.4

7.

8.

9.

9.1

9.2

10. SPECIFICATII..........................................................................................................................19

11. ACCESORII ............................................................................................................................19

2/14

Page 3: Manual Ph Metru

1. Prezentare

Emițătoarele inteligente sunt adăpostite într-o cutie de plastic modular față de 22,5 mm pentru montare pe șine profil omega.

Acestea sunt excelent potrivite pentru măsurarea continuă a mai multor parametri, în legătură cu procesul de control

central PLC. Separate de auto-suficiente emițătoare conlucreaza cu senzori electrochimici și transforma semnale in analogic

sau interfețe de ieșire digitale. Datorită tehnologiei integrate microprocesor emițătoarele oferă configurare ușoară de bază

(un fel de semnal de ieșire de curent sau tensiune, scalarea semnalului de ieșire, limita, etc), în conformitate cu sarcina de

măsurare aplicație specifică prin intermediul USB-interfata si programul software "DinModule ". Producătorul are deja o

ajustare de bază din fabrică. Utilizatorul însuși poate realiza modificări și adaptări ulterioare personalizate ale ajustării de

bază înainte de a începe sau în timpul măsurării. Odată ce emițătorul este pre-reglat funcționează cu butoane de calibrare

rapidă pe partea frontală a emițătorului. Cele 3 butoane, un LED de stare și LC-Display permit calibrarea ușoară cu puncte

de pre-reglate fără PC. În cazul în care senzorul corespunzător este influențată de (de exemplu, soluție tampon pH, soluție

redox (ORP) tampon, soluție de calibrare a conductivității, aerul ambiant etc), standardul pre-reglat ca punct de calibrare

corespunzător, transmițătorul determină datele caracteristice senzorului automat și regleazăcaracteristica de transmisie în

consecință. În plus, o calibrare mai exacta a senzorului și ajustarea corespunzătoare a emițătorului pot fi realizate cu ajutorul

unui PC conectat și programul software "DinModule". Fiecare transmițător dispune de măsurarea parametrului

corespunzător și temperatura, dacă se utilizează un senzor de temperatură integrat cu sondă sau un senzor de temperatură

separat, două ieșiri izolate pentru curent 0 (4) ... 20 mA sau tensiune 0 ... 5 V DC, unul limita plutitoare sau ieșire de releu de

alarmă, precum și o interfață USB pentru scopuri de configurare. pH, potențial redox (ORP) și ISE (electrozi ion-selectivi)

emițătoare sunt potrivite pentru conectare directă cu electrozi combinați și separate de măsurare lanțuri. Celulele de

conductivitate și senzori de oxigen amperometrici pentru conectare la transmițătorul pentru conductivitate și oxigen ar trebui

să fie echipate cu un senzor de temperatură integrat. Emițătoarele accepta senzori de temperatură Pt 1000. Transmițătorul de

clor este potrivit pentru conexiune directă la senzori pentru măsurarea dezinfectante (clor liber și total, dioxid de clor, ozon),

în cazul în care acești senzori dispun de un curent de ieșire cu 2 fire analog.

2. Siguranta

Acest manual de utilizare conține informații fundamentale care trebuie respectate în conexiune cu instalarea, pornirea,

funcționarea și întreținerea emițătoarelor. Prin urmare, este absolut vital pentru utilizator să citiți acest manual înainte de a

lucra cu el.

Calificarea utilizatorului Emițătoarele și întregul sistem de măsurare au fost concepute pentru multi-parametru măsurători analitice. Se presupune că

utilizatorul / operatorul și personalul de întreținere au abilitățile profesionale corespunzătoare și experiență pentru a ști

proprietățile specifice ale sistemelor de măsurare analitică, sa stăpânească manipularea în condiții de siguranță a

substanțelor chimice, pentru exemplu, la întreținerea de electrozi / senzori, și să poată evalua pericolele și riscurile care

decurg din aceasta. Utilizatorul trebuie să se asigure că sunt respectate legislația și procedurile cu privire la protecția muncii,

prevenirea accidentelor și manipularea de produse chimice. Lucrări de instalații electrice

Emițătoarele vin gata de funcționare. Deschiderea aparatului poate expune piese sub tensiune. Conectarea la sursa de

alimentare și ieșirea de releu trebuie să fie făcut fără conexiune la alimentare și cu atenție la instrucțiunile privind

siguranța. O persoană de specialitate care este familiarizat cu pericolele asociate cu acestea ar trebui să facă un astfel de

lucru. Intervenție în aparat va duce la expirarea garanției.

Instalare și pornirea Instalați unitatea și modulele externe, astfel încât condițiile specificate în "Specificații vor fi ținute în orice circumstanțe. Șina

necesar pentru montarea trebuie să fie conectat în mod corect la impamantre - PE. Emițătoarele nu pot fi utilizate în condiții

exterioare, fără carcasă de protecție suplimentară. Nu utilizați cabluri de senzori și de interfață altele decât cele recomandate

de către producător. Pentru senzori și accesorii, se aplica instrucțiunile și reglementările din manualele de utilizare de operare

respective și fișele descriptive

Utilizare corectă Emițătoarele sunt destinate pentru măsurare, control și reglare parametri de analiză. Având în vedere "Specificații" paragraful

din capitolul 8, operare și folosind aparatul pentru această aplicație este utilizarea corectă. Orice aplicație dincolo de acest

lucru și modificări individuale sau extensii sunt necorespunzătoare și vor duce la pierderea dreptului la garanție. Când

conectați aparatul la senzori electrochimici, se ia întotdeauna în considerare viața lor și de uzura normală, deoarece aceasta

poate duce la funcționarea defectuoasă a sistemului de măsurare și reglementarea sau controlul asociate cu acestea.

Utilizatorul trebuie să ia măsuri adecvate pentru a limita efectele nocive ale astfel de funcționări defectuoase.

Instructiuni generale de siguranta Emițătoarele au fost fabricate și testate în conformitate cu indicațiile și standardele relevante pentru echipamente electronice de

măsurare. Acestea au părăsit fabrica în stare inofensiv tehnic. Buna funcționare și fiabilitatea operațională a emițătoarelor va fi

garantată numai dacă se respectă, în general, măsurile de siguranță și instrucțiunile specifice de siguranță prezentate în acest

manual de utilizare, și în instrucțiunile de utilizare ale componentelor. În cazul în care se presupune că funcționarea în

siguranță a aparatului sau a componentelor sale nu mai este posibilă, scoateți aparatul și componentele sale din serviciu și

protejati-l împotriva acționării accidentale. Funcționarea în condiții de siguranță nu va mai fi posibil în cazul în care unitatea

sau componentele sale

3/14

Page 4: Manual Ph Metru

Prezinta deteriorari de la transport a / au fost depozitate în condiții improprii pentru un timp mai lung. Prezinta deteriorari vizibile nu mai funcționează așa cum este descris în acest manual de utilizare.

. Dacă aveți îndoieli, vă rugăm să contactați

furnizorul.

3. Conexiune la terminal, instrucțiuni de operare, reglare din fabrică

Conexiunele terminalului

22,5

mS/µS

99 Dimensiuni in mm

114

Terminal pH / redox(ORP) / ISE* conductivitate 2-electrode-cell

A1 guard ecran

A2 Electrod de masura Fir de semnal

A3 guard ecran

A4 Ecran/electrod de referinta

A5

A6

A7

A8

temp. senzor Pt 1000-1

temp. senzor Pt 1000-1

temp. senzor Pt 1000-2

temp. senzor Pt 1000-2

Pt 1000-1

Pt 1000-1

Pt 1000-2

Pt 1000-2

conductivitate 4-electrode-cell

Electrod de masura

supplying electrode

supplying electrode

electrod de masura

Pt 1000-1

Pt 1000-1

Pt 1000-2

Pt 1000-2

oxygen

anod

catod

anod

chlorine

intrare semnal +

intrare semnal -

intrare semnal +

Pt 1000-1

Pt 1000-1

Pt 1000-2

Pt 1000-2

Pt 1000-1

Pt 1000-1

Pt 1000-2

Pt 1000-2

* * ISE: măsurarea concentrației de ioni cu un electrod ion selectiv

Terminal

B1

B2

B3

B4

B5

B6

B7

B8

Description

power 15…24 V AC/DC

power GND

power GND

power 15…24 V AC/DC

output 1: 0…5 V or 0/4…20mA refer to GND*

output 0: 0…5 V or 0/4…20mA refer to GND*

relay closing contact (30 V DC/1 A, 125 V AC/0.5A)

relay closing contact (30 V DC/1 A, 125 V AC/0.5A)

Nota!

Este recomandat să instalați o unitate de alimentare

separată pentru alimentarea emițătoarelor. Cu aceasta

stabilitatea sistemului de măsurare electrochimică

poate fi asigurată.

O unitate de alimentare potrivita 24V DC / 1A pentru

montare pe sina DIN (pentru alimentarea a max. 10

emițătoare) pot fi livrate la cerere (a se vedea 11. piese

accesorii).

1)

4/14

Page 5: Manual Ph Metru

Afisaj

Emițătoarele din seria MV40xx au un mic ecran în panoul frontal. Acesta

afișează valoarea categoria măsurare 1 și categoria 2 și valori de măsurare a

temperaturii. Este afișat suplimentar starea releelor.

Display-ul se schimbă după 20 de minute automat în modul de economisire energie. Apăsând orice buton al

transmițătorului respectiv afișajul este pornit timp de 20 minute din nou.

Instrucțiuni de operare pentru calibrare

Schimba la modul de calibrare (LED-ul va clipi portocaliu / galben), apăsând pe MODE. Frecvență intermitent al

LED-ul este utilizată ca un indicator de măsurare a stabilității valoare. Intermitent rapid și non-ritmic arată o

valoare de schimbare. Intermitent lent și regulat indică o valoare de măsurare de stabilizare la intrare.

Pentru calibrarea senzorului / electrodului legat cu transmițătorul de însoțire trebuie să fie scufundate sau

influențate de soluțiile standard sau medii de calibrare convenite pentru aceste puncte de calibrare. Apăsarea

butonului C1 calibrează la punctul de calibrare 1 (senzor / electrod într-o soluție standard de calibrare sau punct

de calibrare conform medie 1) și C2 calibrează la punctul de calibrare 2 (senzor / electrod într-o soluție standard

de calibrare sau punct de calibrare conformitate mediu 2). Butoanele de la punctele de calibrare și standardele

corespunzătoare pot fi adaptate cu ajutorul programului de software-ul de configurare.

- pH si ISE O calibrare în două puncte cu două standarde diferite (inclusiv valorile de măsurare așteptate) este

necesară. Din acest motiv fiecare buton trebuie să fi reglat la unul dintre aceste standarde. Pentru aceasta

calibrarea este terminată după calibrare a emițătorului cu senzor conectat la ambele soluții standard și

apăsând a fiecăruia dintre butoanele corespunzătoare

- Potențial redox (ORP), oxigen și conductivitate transmițător

Un singur punct de calibrare într-un standard sau o soluție de testat sau orice alt mediu de calibrare adecvat

este suficientă. Astfel selectabil, ambele butoane pot fi ajustate la identice sau diferite standarde și doar un

singur buton trebuie apăsat pentru calibrare.Redox potential (ORP), oxygen and conductivity transmitter

- Transmiterul de clor Calibrarea trebuie să se facă printr-o comparație sau măsurare de referință (a se vedea punctul 5.5),

deoarece nu există nici un standard de calibrare adecvat disponibil. Concentrația dezinfectanții din mediul

măsurat este determinată de o măsurare sau de laborator metodă independent (adică metoda fotometrică).

Semnalul de ieșire a transmițătorului sau un ecran conectat cu semnalul de ieșire trebuie să fie ajustată cu

ajutorul butoanelor de pe transmițător la valoarea de referință. Majorarea Butonul C1 (0,01 mg / l per

apăsare de buton) și scăderea butonul C2 (0,01 mg / l per apăsare de buton), semnalul de ieșire sau

valoarea afișată. Deci, este foarte ușor să se adapteze ieșire transmițătorului la valoarea curentă măsurată,

determinată prin compararea sau metodă de referință, din mediul în care senzorul este cufunda.

Părăsi modul de calibrare apăsând butonul MODE (LED-ul clipește verde din nou, corespunzător la modul de

măsurare).

Dacă după apăsarea butonului C1 sau C2 (pentru pH după apăsarea butonului de-al doilea) se modifică LED-ul roșu o eroare

de calibrare este produs (defecțiune senzor sau date caracteristice senzori în afara limitelor stabilite, cablu defect, eșec în

timpul calibrarii, etc). Un LED verde indică o calibrare corectă și validă, înseamnă date senzori caracteristice sunt în limitele

definite și caracteristica de transmisie a emițătorului a fost adaptat la datele de senzori. De asemenea, pentru acest

transmițător MV 4060 este o excepție. LED-ul indică o calibrare corectă și valabilă numai după apăsarea butonului mod (de

finisare de calibrare).

Pre-adjustments of the calibration points buttons C1 and C2 at delivery (factory adjustment)

Bu- ton

C1

pH

Solutie Tampon pH acc. NBS

pH = 6.87 at 25 °C

Solutie Tampon pH acc. NBS

pH = 4.0 at 25 °C

conductivitate electrod 2 celule Conductivity Standard

Solution 0.1 N KCl (12.9 mS/cm at 25 °C)

Standard Conductivitate Solutie 0.01 N KCl

(1413 µS/cm at 25 °C)

conductivitate electrod 4 celule Conductivity Standard

Solution 0.1 N KCl (12.9 mS/cm at 25 °C)

Standard Conductivitate Solutie 0.01 N KCl

(1413 µS/cm at 25 °C)

Oxigen

Aer ambient = 100 % air saturatie de oxigen

Masurare in gaze

Aer ambient = 102 % air saturatie de oxigen dizolvat masurat in apa

Redox (ORP)

Solutie tampon Redox UH = 427 mV

(Pt-Ag/AgCl: 220 mV at 25 °C)

Solutie tampon Redox UH = 675 mV

(Pt-Ag/AgCl: 468 mV at 25 °C)

C2

5/14

Page 6: Manual Ph Metru

Categorii de masurare

Pe lângă categoria principală de măsurare (de exemplu pH-ul, conductivitatea, etc) fiecare emițător oferă mai multe așa-numitele

categorii de măsură secundare determinate sau calculate din categoria de măsurare principală și temperatura în categoria de

măsurare. Programul de configurare face posibilă afișarea următoarelor categorii de măsurare la ieșirile a emițătoarelor

relevante.

Categoria de

masura1

Valoare pH

potential redox (ORP) ca valoare

apsoluta voltaj in mV

ISE voltage in mV

conductivity in mS/cm or µS/cm

Categoria de masura2

Electrod de voltaj in mV

Categoria de

masura3 Categoria de

masura4 Categoria de

masura5

MV 4010

MV 4015

MV 4016

MV 4020 MV 4025

MV 4030

MV 4060

*

potential redox (ORP) referred to the standard hydrogen electrode in mV

ion concentration in concentration units

resistance in ohms salinitate in g/kg*

sensor current in nA oxygen partial pres- sure in kPa

air pressure ** oxygen saturation index oxygen concentration in in % mg/l or ppm

concentration in mg/l sensor output current in mA

Salinitatea este un parametru sumă special pentru apa de mare. Valorile de masă de la Institutul National de Oceanografie al Marii Britanii și UNESCO definesc o

gamă de salinitate de 2-42 g / kg. Aceste valori sunt baza de calcul a salinitatii referire la conductivitatea măsurată. Din cauza unei game limitate de 2 ... 42 g / kg

un calcul de salinitate este posibil numai în domenii de măsurare de 0 ... 20 mS / cm și 0 ... 100 mS / cm conductivitatea. ** Numai modelul MV 4030-LK măsoară presiunea aerului actuală.

4.

4.1

Diagrame de conetare senzori

Senzor de temperatura

Circuit cu 4 fire

A5 PT1000-1

A5 A6 A7 A8 Cablu de masura K43-PT/...

cable core

A6 PT1000-1

cable core

A7 PT1000-2

shield

A8 PT1000-2

shield

Pt 1000

Circuit de 3 fire Circuit de 2 fire

A5 A6 A7 A8 A5 A6 A7 A8

Pt 1000 Pt 1000

6/14

Page 7: Manual Ph Metru

4.2 pH/redox (ORP) and Ion-Selective (ISE) Electrode

Electrod Combinat

A1 guard

A1 A2 A3 A4 measuring cable K43/...

-

A2 pH-signal

cable core

A3 guard

-

A4 reference

shield

Electrod de referinta si de masura separati

A1 A2 A3 A4

A1 guard

pH-sensor reverence-electrode

- -

A2 Semnal pH

cable core -

A3 guard

- -

A4 refeerinta

shield cable core

eletrod de pH combinat u senzzor de

temperatura integrat (K 54 cablu triaxial)

eletrod de pH combinat u senzzor de temperatura

integrat (K 19 cablu multifilar)

A5 A6 A7 A8 A5 A6 A7 A8

A1 A2 A3 A4 A1 A2 A3 A4 PE

A.1 guard

measuring cable K54/...

measuring cable K19/...

-

-

A2 Semnal pH

cable core (bl)

cable core

A3 guard

-

-

A4 Referinta

inner shield (rt)

shield

A5 PT1000-1

bridge circuit to A.6

green

A6 PT1000-1

bridge circuit to A.5

brown

A7 PT1000-2

bridge circuit to A.8

yellow

A8 PT1000-2

outer shield (grey)

white

7/14

Page 8: Manual Ph Metru

În special pentru conectarea cablului de măsurare și cablul triaxial pentru electrozii de masurare pH, redox și ISE la intrare

rezistivă a transmiterului trebuie sa acorde atenție firului de semnal intern sa fie cât mai scurtă posibil și sa rămâna acoperit, cat

mai departe de ecran.

Cabu de semnal

intern

ecran

4.3 Celula de masurare Conductivitate, Oxigen si Senzor de Clor

conductivitate electrod cu 2 celule

A1 A2 A3 A4

A1 -

Cablu de

masura K43

Cablu de

masura K18

conductivitate electrod cu 4 celule

-

-

A2 measuring electrode

Miez

alb

A3 measuring electrode

ecran

ecran

A4 -

-

-

A5 PT1000-1

-

gri

A6 PT1000-1

-

Verde

A7 PT1000-2

-

maro

A8 PT1000-2

-

roz

A1 A2 A3 A4

measuring electrode

measuring electrode

supplying electrode

supplying electrode

A1 Electrod de

masura

Cablu de

masura K17 roz

A2 Electrod

furnizor

maro

A3 Electrod

furnizor

verde

A4 Electrod de

masura

gri

8/14

A5 PT1000-1

shield

A6 PT1000-1

alb

A7 PT1000-2

galben

A8 PT1000-2

albastru

Page 9: Manual Ph Metru

senzor de oxigen

A1 A2 A3 A4

catod anod

A1 -

Cablu de

masura K39 -

A2 Cathode

alb

A3 Anode

ecran

A4 -

-

A5 PT1000-1

gri

A6 PT1000-1

maro

A7 PT1000-2

verde

A8 PT1000-2

roz

Senzor pentru dezinfectanti (clor, Dioxid de clor, ozon)

A1 A2 A3 A4

- +

An integrated or separated temperature sensor connected as per para. 4.1.

5.

5.1

Calibrarea din Butoane

Calibrare transmițător pH (transmițător ISE)

Pentru o calibrare ușoara și simpla "în timpul funcționării" a unui emițător conectat cu electrodul de însoțire folosi cele trei

butoane de pe partea frontală a emițătorului. Butoane C1 și C2 definesc punctele de calibrare, ce corespund soluțiilor

standard inclusiv estimate de măsură, gamă. În cazul în care electrodul conectat este cufundat în (de exemplu, soluție tampon

de pH) in conformitate cu punctele de calibrare standard, transmițătorul calculează automat datele caracteristice ale

senzorului și reglează funcția de transmitere în conformitate cu aceste date.

Ca un exemplu calibrarea unui transmițător pH-ului cu reglare fabrică, alin. 3 este descrisa. Programul software de

configurare face posibilă să se schimbe aceste valori la alte soluții tampon. Această caracteristică utilizează în mod automat,

valoarea corectă pH-ului în funcție de temperatura reală pentru măsurători și etalonări, cu senzor de temperatura conectat

(acorde o atenție la echilibrul de temperatura de electrodul și senzor de temperatură). Este egal ce soluție tampon este

utilizata pentru prima oară pentru calibrare; doar este necesară utilizarea butonului corect pentru soluția tampon conexă de

calibrare corectă.

Operare: Transmițătorul este în modul de măsurare normal, indicat prin clipirea LED-ului verde.

C2 MODE C1

green

9/14

Page 10: Manual Ph Metru

Schimba la modul de calibrare apăsând butonul MODE. LED-ul isi schimbă culoarea în portocaliu.

C2 MODE C1

orange

Scufundați electrodul / senzorul în prima soluție tampon pH. LED-ul clipeste rapid aritmic portocaliu indicand

valoarea de măsură in schimbare. În cazul în care valoarea măsurată se stabilizează, clipirile vor fi lente și ritmice.

Acum, apăsați pe butonul de C1 în conformitate cu prima soluție tampon (punctul prima calibrare de exemplu, pH

6,87)

C2 MODE

orange

Clătiți electrodul / senzorul cu apă distilată / apă deionizată și se scufundă-l în cea de a doua soluție tampon.

LED-ul portocaliu indica unui valoare de măsură de stabilizare, de intermitent încet și ritmic.

Acum, apăsați butonul C2 în conformitate cu ajustate soluția tampon a doua (al doilea punct de calibrare de exemplu pH 4.01).

C2 MODE

orange

Calibrarea este corectă dacă după apăsarea butonului pentru al doilea tampon LED, se modifică la verde. Toate datele

caracteristice ale electrodului / senzorului sunt în limite acceptabile și caracteristica de transmisie a emițătorului este

ajustată în conformitate cu aceste date. Dacă LED-ul, se schimbă o perioadă scurtă de timp la roșu o eroare de

calibrare a avut loc sau datele senzorului caracteristice sunt limite definite in afara. Datele de calibrare stabilite în

această calibrare nu sunt acceptate și nu sunt stocate în acest caz. Acordați atenție că o eroare de calibrare este afișată

după utilizarea celei de a doua soluții standard.

C2 MODE

green

C1 C2 MODE

red

C1

C1

C1

Pentru a termina calibrarea și schimba la modul normal de măsurare apăsați butonul MODE. Acum, LED-ul se aprinde

intermitent din nou verde.

C2 MODE

orange

C1 C2 MODE

green

C1

Calibrarea unui lanț de măsurare-ion selectiv (ISE electrod combinat sau separat electrod de măsurare-ion selectiv și electrod de

referință), în legătură cu o ISE transmițător este aproape identic cu calibrarea pH-ului. Este o calibrare în două puncte, cu soluții

standard corespunzătoare pentru tipul de ioni care urmează să fie stabilite.. Soluțiile standard folosite cu unitatea lor de

concentrare (de exemplu, mg / l, ppm etc) determina domeniul de măsurare și unitatea concentrației pentru ieșirea de măsurare.

Utilizați butoanele C1 și C2 pentru o simpla "în timpul funcționării" calibrare cu standardele definite de asemenea. Reglați

butoanele în conformitate cu standardele, care ar trebui să includă gama estimată de măsurare. Datorită valorii diferită a ionilor o

verificare a datelor caracteristice ale senzorului nu este posibilă. O calibrare corectă are nevoie întotdeauna un punct de calibrare

(standard de însoțire), ar trebui să fie amplasat în partea a treia deasupra și un punct de calibrare este situat în sub a treia parte a

domeniului de măsurare. Acorde o atenție la dependența de temperatură a soluțiilor standard. Calibrarea are nevoie de experiențe

speciale și prezență precum toate aplicatiile cu electrozi ion-selectivi (ISE).

10/14

Page 11: Manual Ph Metru

5.2 Callibrare transmiter de Conductivitate

Pentru măsurarea conductivității unui singur punct de calibrare este suficientă. Prin intermediul celor trei butoane și definirea

unui punct de calibrare corect calibrarea transmițătorului cu celula de măsurare de însoțire "în timpul funcționării" este foarte

usoara și simplă. Utilizați punctele de calibrare definite de către conform reglare fabrică. alin. 3 în conformitate cu domeniul

de măsurare estimat. Dependența de temperatură a conductivității a acestor standarde sunt stocate în emițător și se calculează în

conformitate cu temperatura reală dată de senzorul de temperatură integrat în celula de măsurare (atentie la timpul necesar

pentru echilibru de temperatură a senzorului cu temperatură mediului și). Alte puncte de calibrare pot fi reglate cu ajutorul

programului de software-ul de configurare. Întotdeauna unui calibrare corect bazată pe utilizarea stocate soluțiile standard de

calibrare în conformitate cu butoanele de însoțire

Operare: Transmiterul se afla in modul de masurare, indicat de LED-ul verde intermitent

C2 MODE C1

green

Schimbati la modul Calibrare apasand butonul MODE. LED-ul isi schimba culoarea in portocaliu

C2 MODE C1

orange

Acum, scufundați celula de conductivitate gata să măsoare (înainte de clătire de calibrare cu apă distilată /

deionizată) în soluția standard de conductivitate, în conformitate cu butonul C1 sau C2 programat. Un clipit rapid

intermitent non-ritmic a LED-ului portocaliu indică valoarea de măsurare in schimbare. În cazul în care valoarea

măsurată se stabilizează, Indicatorul clipeste lent și ritmic.

Acum, apăsați butonul în conformitate cu soluția standard de conductivitate utilizată (punct de calibrare).

C2 MODE

orange

Calibrarea s-a terminata corect dacă după apăsarea butonului se schimbă LED de culoare verde. Datele caracteristice

ale celulei (constanta celulei) este în limite acceptabile și caracteristica de transmisie a emițătorului este ajustată în

conformitate cu aceste date. În cazul în care se schimbă LED pentru o perioadă scurtă de timp la roșu o eroare de

calibrare s-a produs sau datele celulei sunt în afara limitelor definite. Datele de calibrare determinate nu sunt

acceptate și nu sunt stocate în acest caz.

C2 MODE

green

C1 C2 MODE

red

C1

C1

Pentru a finaliza schimbarea de calibrare pentru modul de măsurare normal prin apăsarea butonului MODE. Acum,

LED-ul se aprinde intermitent din nou verde.

C2 MODE

orange

C1 C2 MODE

green

C1

11/14

Page 12: Manual Ph Metru

5.3 Calibrarea Transmiter de Oxigen

Calibrarea și reglarea unui emițător de oxigen împreună cu senzorul de însoțire sunt complet identice cu calibrarea unui

transmițător conductivitate pentru că este un singur punct de calibrare prea. Ajustarea din fabrică în conformitate cu Paragraf

3 pentru butoanele C1 și C2 definesc punctele de calibrare, care corespund pentru o calibrare usoara a senzorului in aer

pentru diferite aplicații. Pentru ambele aplicații, măsurarea conținutului de oxigen din aer (de exemplu, pentru tehnologia de

compostare sau supraveghere a aerului în interiorul clădirilor) și măsurarea oxigenului dizolvat în apă sau lichide,

întotdeauna ambiantul cu valoare medie 20,9 Vol. -.% Oxigen este utilizat ca mediu de calibrare (cum ar fi un standard).

Acordați atenție la timpul necesar pentru echilibru de temperatură de temperatură mediu și sonda integrate în senzor. Alte

puncte de calibrare pot fi reglate cu ajutorul programului de software-ul de configurare. Întotdeauna o calibrare corectă de

oxigen se bazează pe utilizarea punctelor de calibrare predefinite în conformitate cu butoanele de însoțire. În plus, să acorde

o atenție pentru a da senzorului timpul necesar pentru echilibru de temperatură în special pentru schimbări rapide de

temperatură prin punerea senzorului din apă în aer

5.4 Calibrarea transmiterului Redox (ORP)

Măsurarea Potențialului redox (ORP) este măsurarea potențialului între electrodul de măsură platină și electrodul de

referință, in cele mai multe din cazuri combinat ca o unitate comună, redox sau ORP electrodul combinat. Ieșirea din

emițătoare urmează acest potențial proporțional. De obicei o calibrare nu este necesară și in cele mai multe din cazuri nu e

solicitată. Oricum, funcționarea corectă a sistemului de de măsură redox poate fi verificată cu ajutorul soluțiilor de calibrare

redox (ORP). Astfel, la cerere și / sau necesară adaptarea caracteristicii transmițător la rezultatul de calibrare este posibilă ca

o transformare liniară, astfel că ieșirea de măsură este identică cu potențialul redox dat (ORP) soluție standard (de calibrare și

reglare). Calibrarea unui transmițător redox (ORP) este complet identică cu calibrarea unui transmițător conductivitate cu un

singur punct de calibrare. În conformitate cu domeniul de de măsură estimat sunt definite două soluții standard redox diferite

pentru butoanele 1 și 2 ca puncte de calibrare în conform ajustarea din fabrică. alin. 3. Dependența de temperatură a

potențialului redox a acestor standarde sunt stocate în transmițător, dar poate fi utilizat în cazul în care o senzor de

temperatură este conectat doar (atentie la timpul necesar pentru echilibru de temperatură a senzor de temperatură mediului

și). Alte puncte de calibrare pot fi reglate cu ajutorul programului de software-ul de configurare. Baza pentru o calibrare

corectă este întotdeauna de a folosi soluția standard de calibrare stocate în conformitate cu butonul de însoțire.

5.5 Calibrarea Transmiterului de Clor

Calibrarea transmițătorului clor este o calibrare, cu un singur punct. La această valoare curentă clor-ul mediului în care

senzorul este imersat trebuie să fie măsurată cu o trimitere sau măsurare comparație (de exemplu, metoda DPD-). Valoarea de

ieșire a emițătorului (semnal analogic Ieșirea, de afișare conectat cu ieșire analogică, afișare pe unitatea de afișare), trebuie să

fie ajustate la valoarea curentă astfel determinata dacă senzorul este cufundat în același mediu.

Operare: Transmițătorul este în modul de măsurare normală, indicat prin clipirea LED verde.

C2 MODE C1

verde

Schimba la modul de calibrare apăsând butonul MODE. LED-ul se schimbă culoarea de la portocaliu.

C2 MODE C1

portocaliu

Acum, reglați cu C1 (valoarea crește cu fiecare singură apăsare de buton, la 0,01 mg / l) și C2 (valoare scade cu

fiecare singură apăsare de buton, la 0,01 mg / l) valoarea exactă clor măsurată prin măsurare de referință. (de

exemplu DPD). Pentru o mare diferență butoanele pot fi apăsat un timp mai îndelungat. Important pentru acest

calibrare este verificarea vizuală a semnalului de ieșire dat de transmițător. Acest lucru poate fi realizat fie prin

intermediul software-ului "DinModule", valoarea afișată pe unitatea de afișare AZ 3000 sau prin semnalul analogic

de ieșire. Prin utilizarea unui semnal de ieșire analogic pentru verificarea ajustarea este important pentru a opri

funcția "HOLD" în timpul calibrării ("DinModule" software de configurare, buton). În caz contrar, semnalele de

ieșire analogice sunt înghețate în timpul calibrării (a se vedea, de asemenea, alin. "6.3 Configurare") și nu se poate

verifica nici o ajustare.

C2 MODE

portocaliu

C1

12/14

Page 13: Manual Ph Metru

Pentru a termina calibrarea, schimba modul de măsurare normal prin apăsarea butonului MODE.

C2 MODE C1

C2 MODE

green

C1 C2 MODE

red

C1

Acum, LED-ul se aprinde intermitent din nou verde. Calibrarea este corect terminata, toate datele caracteristice ale

electrodului / senzorului sunt în limite acceptabile și caracteristica de transmisie a emițătorului este ajustată în

conformitate cu aceste date. Transmițătorul lucrează în modul de măsurare din nou. În cazul în care se schimbă LED

pentru o perioadă scurtă de timp la roșu o eroare de calibrare s-a produs sau datele senzorului caracteristice sunt in afara

limitelor definite. Datele de calibrare stabilite în această calibrare nu sunt acceptate și nu sunt stocate în acest caz.

13/14

Page 14: Manual Ph Metru

9. Maintenance, Disposal

Emițătoarele din seria MV 40xx sunt aproape fără întreținere. În cazul murdări este permisă numai să curățați exteriorul cu o

cârpă umedă. Pentru aceasta modulele trebuie să fie deconectat de la sursa de alimentare! Curățarea cu detergent agresiv,

CARE conține solvenți (de exemplu, acetona) este interzisă. Altfel deteriorarea carcasei ABS poate apărea.

9.1 Mentenanta Senzor / Electrode

Pentru întreținerea și depozitarea senzorilor / electrozilor vă rugăm să respectați manualele corespunzătoare ale senzorilor /

electrozilor.

9.2 Înlăturare

Va rugam sa ne trimiteti instrumentele de măsură vechi și senzorii pentru eliminare. Sensortechnik Meinsberg GmbH se duce

înapoi gratuit și reciclează / dispune resturi electronice într-un mod competent.

Atenție!

Nu aruncați instrumente de măsurare vechi, la deșeurile menajere, acest lucru este ilegal. Vă rugăm să evitati eliminarea la

punctele de colectare publice.

10. Specificatii

Specificatii generale pentru transmiterele de masurare:

Configuratie prin intermediul interfeței USB și program de configurare corespunzătoare

Scaling și determinarea semnalelor de ieșire analogice

meniul de calibrare, definiția din punctele de etalonare

Compensarea temperaturii

LCD grafic, 48 x 64 pixel, luminat, afisaj pentru 3 valori (valoare 1, valoare 2 si temperatura)

MODE: Schimbare la modul calibrare C1, C2: Valori de calibrare (configuratie predefinita) sau ajustre a semnalului

de iesire prin comparatie sau masuratoare de referinta (transmiter de clor) LED multicolor (semnalizare masurare stabila) LED portocaliu: Calibrare LED verde: Masurare LED rosu: Eroare de calibrare

2 x 0(4) ... 20 mA or 0 ... 5 V, Izolate incarcare 500 acuratete 0,2 %

incarcare 2 kΩ, acuratete 0,2 %

USB, conectabil bus la o retea prin RS-232

Maxim inchidere contact 125 V AC, 60 V DC; 30 VA

15 ... 24 V AC/DC, aprox. 1.5 VA

0 ... 50 °C

acc. EN 61326 class B

carcasă din plastic pentru montare pe șină DIN EN 50022-35, grad de protectie IP 40 terminale pentru cabluri Secțiune 0.2 ... 2.5 mm2; 3-pini soclu pentru RS-232 cable connector; optional sina pentru conector bus

Afisaj

Functiile Butoanelor

Indicator de Status

Semnale de Iesire

Iesiri de Curent

Iesiri de Voltaj Interfata

Iesire de releu

Sursa de alimentare

Temperatura ambientala

EMC

Carcasa Conexiuni electrice

Domeniile de măsurare, electrozi / senzori recomandat potriviti pentru conectarea la emițătoarele și desenele dimensionale de

incintă în conformitate cu fișele individuale de date tehnice detaliate.

11. Accesorii

Accesorii optionae si echipamente aditionale

Interface cable connection for the USB connection (3 pins phone plug / USB connector) and PC software program „DINModule“

Sina pentru conector bus Connector for direct mounting on the plastic enclosure for network connection of several measuring transmitters by the RS-232 interface

Unitate de alientare Power supply unit in an enclosure for mounting on rail tracks (input 85... 264 V AC; output 24 V)

Protectia carcasei IP 65 Carcasă de protecție pentru montaj pentru unul sau mai multe emițătoare de măsurare pe teren în aer liber

Unitate afisaj AZ 3000 Modul într-o incintă pentru montarea pe sine pentru afișarea a până la 8 valori măsurate ale sistemului de

logare de date inclusiv, definiție de a 2 conexiuni valori de măsurare virtuale, 2 ieșiri analogice și de

transmitere a datelor (convertor de interfață)

14/14

Interfata MV