-1239 2 -1240 2 Manifold Blocks - Hydraulic / Pneumatic Lateral Through Hole, T-Shaped Hole Manifold Blocks - Hydraulic / Pneumatic Lateral and Vertical Through Hole For details of recommended tapered male thread tightening torque and through pilot holes, see P.1224. EMounting hole shape can be selected freely. EStandard hole shape is selected when no hole shape modification is specified. 6.3 Thread JIS B0203 Rc(PT) JIS B0202 G(PF): ISO 228-1 Compatible ANSI/ASME B.I.20.1-1983(NPT) ∙ Mounting Hole Change Through Hole (NA) d Tapped Hole (T) Mx2 Mx2 M Counterbore Tapped Hole (ZT) D1 h1 Mx2 d1 M d D h Counterbore Hole *Drawing for 3 Circuit Type is selected. The total number of Q, R, S, G and K threads is 11. <L Dimension Calculation> Ex.: For BMTFLP3- ~ -P35, L=NxP+2E= (Number of Circuits 3 - 1) x 35 + 2 x 30 = 130 2-Hole Selection E X X L-2X F Y E A B A/2 L NxP P R S Q G K Number of Circuits 2 Number of Circuits 3 Number of Circuits 1 Mounting Hole Dimension d D h D1 d1 h1 M5 5.5 9.5 5.5 8 4.2 4.5 M6 6.6 11 6.5 9.5 5.1 5.5 M8 8.5 14 8.5 11 6.8 6.5 No. Unit Price Pitch (P) Standard Pitch (P) Configurable Usage: Hydraulic Usage: Pneumatic Usage: Hydraulic 40 Sq. 60 Sq. 25 Sq. 30x40 Sq. 50 Sq. 40 Sq. 60 Sq. BMTF BMTFM BMTFR BMTFS BMTFC BMTFL BMTFLR BMTAC BMTAF BMTAFA BMTAL BMTALA BMTFMP BMTFRP BMTFLP 1 - - - 2 3 4 5 6 No. Unit Price Pitch (P) Standard Pitch (P) Configurable Usage: Hydraulic Usage: Pneumatic Usage: Hydraulic 30x35 Sq. 40 Sq. 60 Sq. 70 Sq. 30x40 Sq. 50 Sq. 70 Sq. 30x35 Sq. 40 Sq. 60 Sq. BMIS BMIF BMIFR BMIFS BMIFLR BMIL BMIAF BMIAFA BMIAL BMIAB BMISP BMIFP BMIFRP BMIFLRP 1 - - - - 2 3 4 5 - - 6 - - EMounting hole shape can be selected freely. EStandard hole shape is selected when no hole shape modification is specified. 6.3 2-Hole Selection E X X L-2X F Y E A B A/2 L NxP P R S G K Number of Circuits 1 Number of Circuits 2 Number of Circuits 3 * Drawing for 3 Circuit Type is selected. The total number of R, S, G and K threads is 8. <L Dimension Calculation> Ex.: For BMIFP3- ~ -P35, L=NxP+2E= (Number of Circuits 3 - 1) x 35 + 2 x 35 = 140 ∙ Mounting Hole Change Through Hole (NA) d Tapped Hole (T) Mx2 Mx2 M Counterbore Tapped Hole (ZT) D1 h1 Mx2 d1 M Standard Hole Shape d D h Counterbore Hole Mounting Hole Dimension d D h D1 d1 h1 M5 5.5 9.5 5.5 8 * 4.2 4.5 M6 6.6 11 6.5 9.5 5.1 5.5 M8 8.5 14 8.5 11 6.8 6.5 * Only for EN 1.4301 Equiv., d1 dimension is 4.3. Thread JIS B0203 Rc(PT) JIS B0202 G(PF): ISO 228-1 Compatible ANSI/ASME B.I.20.1-1983(NPT) Mounting Holes Mounting Holes For details of recommended tapered male thread tightening torque and through pilot holes, see P.1224. By inserting "G-" before part number, "PT Threads (Tapered Female Threads)" can be changed to "PF Threads (Parallel Female Threads)" in compliance with "JIS B 0202" (Unit Price remains the same). By inserting "G-" before part number, "PT Threads (Tapered Female Threads)" can be changed to "PF Threads (Parallel Female Threads)" in compliance with "JIS B 0202" (Unit Price remains the same). Standard Hole Shape EMaterial of 70 Square is EN AW-6063 Equiv. Usage Type Material Surface Treatment Max. Operating Pressure Pitch (P) Standard Pitch (P) Configurable 30x35 Sq. 40 Sq. 60 Sq. 70 Sq. 30x40 Sq. 50 Sq. 70 Sq. 30x35 Sq. 40 Sq. 60 Sq. Hydraulic BMIS BMIF - BMIL - - - BMISP BMIFP - EN 1.0038 Equiv. Trivalent Chromate 20.6MPa≈210kgf/cm 2 or less - BMIFR BMIFLR - - - - - BMIFRP BMIFLRP EN 1.4301 Equiv. - - BMIFS - - - - - - - - EN 1.4401 Equiv. Pneumatic - - - - BMIAF BMIAL BMIAB - - - EN AW- 5052 Equiv. - 1MPa≈10kgf/cm 2 or less - - - - BMIAFA - - - - - Clear Anodize Part Number - Q - R - S - G - K - P Type Mounting Hole Change Number of Circuits BMTFMP BMTAC G-BMTAC T T 2 3 3 - - - Q1 QM3 QM3 - - - R1 R1 R1 - - - S1 S1 S1 - - - G2 G1 G1 - - - K2 K1 K1 - P30 (G Thread) Part Number - R - S - G - K - P Type Mounting Hole Change Number of Circuits BMIAF BMIFRP G-BMIFRP ZT ZT ZT 3 3 3 - - - R1 R2 R2 - - - S2 S1 S1 - - - G2 G2 G2 - - - K2 K2 K2 - - P25 P25 (G Thread) Part Number Rc (PT), NPT, M (Coarse) Selection Pitch P Number of Pitches N Total Number of Q, R, S, G and K Threads A B E F X Y Mounting Hole Type Mounting Hole Change Number of Circuits Q, R, S G, K Standard Configurable 1mm Increment M Hydraulic (40 Sq.) NA (Through) T (Tapped) ZT (Counterbore Tapped) 1 1 (1/8) 2 (1/4) 3 (3/8) 1N (NPT1/8) 2N (NPT1/4) 3N (NPT3/8) 2 (1/4) 3 (3/8) 4 (1/2) 2N (NPT1/4) 3N (NPT3/8) 4N (NPT1/2) - - 0 5 40 40 35 20 20 7 M6 Pitch Standard BMTF BMTFM BMTFR BMTFS BMTFC Pitch Configurable BMTFMP BMTFRP 2 40 25~50 1 8 3 2 11 4 3 14 5 4 17 6 30~50 5 20 Hydraulic (60 Sq.) 1 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) - - 0 5 60 60 30 30 7.5 8 M8 Pitch Standard BMTFL BMTFLR Pitch Configurable BMTFLP 2 60 35~60 1 8 3 2 11 4 3 14 5 4 17 6 40~60 5 20 Pneumatic (25 Sq.) T (Tapped) 1 1 (1/8) M3 (M3) M4 (M4) 5 (M5) 1 (1/8) M3 (M3) M4 (M4) 5 (M5) - - 0 5 25 25 20 12.5 10 4 M5 Pitch Standard BMTAC 2 15 1 8 3 2 11 4 3 14 5 4 17 6 5 20 Pneumatic (30x40 Sq.) NA (Through) T (Tapped) ZT (Counterbore Tapped) 1 1 (1/8) 2 (1/4) 5 (M5) 1N (NPT1/8) 2N (NPT1/4) 1 (1/8) 2 (1/4) 5 (M5) 1N (NPT1/8) 2N (NPT1/4) - - 0 5 30 40 20 20 7.5 7 M5 Pitch Standard BMTAF BMTAFA 2 30 1 8 3 2 11 4 3 14 5 4 17 6 5 20 Pneumatic (50 Sq.) 1 2 (1/4) 3 (3/8) 4 (1/2) 2 (1/4) 3 (3/8) 4 (1/2) - - 0 5 50 50 25 25 8.5 8.5 M8 Pitch Standard BMTAL BMTALA 2 40 1 8 3 2 11 4 3 14 5 4 17 6 5 20 EBy inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BMTF) For ordering, see the Ordering Example. EFor Q, R, S, G and K, specify 1, 2, 3, 4, 5, 6, M3, M4, 1N, 2N, 3N or 4N indicated before ( ). ESingle Circuit is not available for Pitch Configurable Type. ESpecify the pitch taking into consideration the necessary dimensions for fitting the couplings. EOnly 6 Circuit Type has an additional mounting hole at the midpoint of the overall length. (Except for 25 Sq.) Part Number Rc (PT), NPT, M (Coarse) Selection Pitch P Number of Pitches N Total Number of R, S, G and K Threads A B E F X Y Mounting Hole Type Mounting Hole Change Number of Circuits R, S G, K Standard Configurable 1mm Increment M Hydraulic (30x35 Sq.) NA (Through) T (Tapped) ZT (Counterbore Tapped) 1 1 (1/8) 2 (1/4) 1 (1/8) 2 (1/4) - - 0 4 30 35 30 17.5 17 6 M5 Pitch Standard BMIS BMISP 2 30 20~50 1 6 3 2 8 4 3 10 5 4 12 Ed1 dimension in ( ) is only applicable to EN 1.4301 Equiv. 6 25~50 5 14 Hydraulic (40 Sq.) 1 1 (1/8) 2 (1/4) 3 (3/8) 1N (NPT1/8) 2N (NPT1/4) 3N (NPT3/8) 2 (1/4) 3 (3/8) 4 (1/2) 2N (NPT1/4) 3N (NPT3/8) 4N (NPT1/2) - - 0 4 40 40 35 20 20 7 M6 Pitch Standard BMIF BMIFR BMIFS Pitch Configurable BMIFP BMIFRP 2 40 25~50 1 6 3 2 8 4 3 10 5 4 12 6 30~50 5 14 Hydraulic (60 Sq.) 1 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) - - 0 4 60 60 30 30 7.5 8 M8 Pitch Standard BMIFLR Pitch Configurable BMIFLRP 2 60 35~60 1 6 3 2 8 4 3 10 5 4 12 6 40~60 5 14 Hydraulic (70 Sq.) 1 3 (3/8) 4 (1/2) 6 (3/4) 6 (3/4) 8 (1) - - 0 4 70 70 40 35 16.5 8 M8 Pitch Standard BMIL 2 60 1 6 3 2 8 4 3 10 Pneumatic (30x40 Sq.) 1 1 (1/8) 2 (1/4) 5 (M5) 1N (NPT1/8) 2N (NPT1/4) 1 (1/8) 2 (1/4) 5 (M5) 1N (NPT1/8) 2N (NPT1/4) - - 0 4 30 40 20 20 7.5 7 M5 Pitch Standard BMIAF BMIAFA 2 30 1 6 3 2 8 4 3 10 5 4 12 6 5 14 Pneumatic (50 Sq.) 1 2 (1/4) 3 (3/8) 4 (1/2) 2 (1/4) 3 (3/8) 4 (1/2) - - 0 4 50 50 25 25 8.5 8.5 M8 Pitch Standard BMIAL 2 40 1 6 3 2 8 4 3 10 5 4 12 6 5 14 Pneumatic (70 Sq.) 1 4 (1/2) 6 (3/4) 4 (1/2) 6 (3/4) 8 (1) - - 0 4 70 70 40 35 16.5 8 M8 Pitch Standard BMIAB 2 60 1 6 3 2 8 4 3 10 EBy inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BMIF) For ordering, see the Ordering Example. EFor R, S, G and K, specify 1, 2, 3, 4, 6, 8, 1N, 2N, 3N or 4N indicated before ( ). ESingle Circuit is not available for Pitch Configurable Type. ESpecify the pitch taking into consideration the necessary dimensions for fitting the couplings. EOnly 6 Circuit Type has an additional mounting hole at the midpoint of the overall length. Usage Type Material Surface Treatment Max. Operating Pressure Pitch (P) Standard Pitch (P) Configurable 40 Sq. 60 Sq. 25 Sq. 30x40 Sq. 50 Sq. 40 Sq. 60 Sq. Hydraulic BMTF BMTFL - - - - BMTFLP EN 1.0038 Equiv. Trivalent Chromate 20.6MPa≈210kgf/cm 2 or less BMTFM - - - - BMTFMP - Electroless Nickel Plating BMTFR BMTFLR - - - BMTFRP - EN 1.4301 Equiv. - BMTFS - - - - - - EN 1.4401 Equiv. - BMTFC - - - - - - Brass - 1MPa≈10kgf/cm 2 or less Pneumatic - - BMTAC BMTAF BMTAL - - Aluminum Alloy 5000 series - - - - BMTAFA BMTALA - - Clear Anodize EBMTFLRP (EN 1.4301 Equiv., 60 Sq., Pitch Configurable) is available on our website.

Upload: dangkien

Post on 27-Mar-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Manifold Blocks - Hydraulic / Pneumatic · PDF file2 -1239 2 -1240 Manifold Blocks - Hydraulic / Pneumatic ... 3 2 8 4 3 10 EBy inserting "G-" before part number, the thread type can

-12392 -12402

Manifold Blocks - Hydraulic / PneumaticLateral Through Hole, T-Shaped Hole

Manifold Blocks - Hydraulic / PneumaticLateral and Vertical Through Hole

For details of recommended tapered male thread tightening torque and through pilot holes, see P.1224.

E Mounting hole shape can be selected freely.

E Standard hole shape is selected when

no hole shape modifi cation is specifi ed.

6.3

Thread

JIS B0203 Rc(PT)

JIS B0202 G(PF): ISO 228-1 Compatible

ANSI/ASME B.I.20.1-1983(NPT)

∙ Mounting Hole Change

Through Hole (NA)

d

Tapped Hole (T)

Mx2Mx2

M

Counterbore Tapped Hole (ZT)

D1

h1 Mx2

d1

M

dD

h

Counterbore Hole

* Drawing for 3 Circuit Type is selected. The total number of Q, R, S, G and K threads is 11.

<L Dimension Calculation> Ex.: For BMTFLP3- ~ -P35, L=NxP+2E= (Number of Circuits 3 - 1) x 35 + 2 x 30 = 130

2-Hole Selection

E

X XL-2X

F

Y

E A

B

A/2

L

NxP

PR

S

Q

G K

Number of Circuits 2

Number of Circuits 3

Number of Circuits 1

Mounting Hole Dimension d D h D1 d1 h1

M5 5.5 9.5 5.5 8 4.2 4.5

M6 6.6 11 6.5 9.5 5.1 5.5

M8 8.5 14 8.5 11 6.8 6.5

No.

Unit Price

Pitch (P) Standard Pitch (P) Confi gurable

Usage: Hydraulic Usage: Pneumatic Usage: Hydraulic

40 Sq. 60 Sq. 25 Sq. 30x40 Sq. 50 Sq. 40 Sq. 60 Sq.

BMTF BMTFM BMTFR BMTFS BMTFC BMTFL BMTFLR BMTAC BMTAF BMTAFA BMTAL BMTALA BMTFMP BMTFRP BMTFLP

1 - - -

2

3

4

5

6

No.

Unit Price

Pitch (P) Standard Pitch (P) Confi gurable

Usage: Hydraulic Usage: Pneumatic Usage: Hydraulic

30x35 Sq. 40 Sq. 60 Sq. 70 Sq. 30x40 Sq. 50 Sq. 70 Sq. 30x35 Sq. 40 Sq. 60 Sq.

BMIS BMIF BMIFR BMIFS BMIFLR BMIL BMIAF BMIAFA BMIAL BMIAB BMISP BMIFP BMIFRP BMIFLRP

1 - - - -

2

3

4

5 - -

6 - -

E Mounting hole shape can be selected freely.

E Standard hole shape is selected when

no hole shape modifi cation is specifi ed.

6.3

2-Hole Selection

E

X XL-2X

F

Y

EA

B

A/2

L

NxP

P

R

S

G K

Number of Circuits 1

Number of Circuits 2

Number of Circuits 3

* Drawing for 3 Circuit Type is selected. The total number of R, S, G and K threads is 8.

< L Dimension Calculation> Ex.: For BMIFP3- ~ -P35, L=NxP+2E= (Number of Circuits 3 - 1) x 35 + 2 x 35 = 140

∙ Mounting Hole Change

Through Hole (NA)

d

Tapped Hole (T)

Mx2Mx2

M

Counterbore Tapped Hole (ZT)

D1

h1 Mx2

d1

M

∙ Standard Hole Shape

dD

h

Counterbore Hole

Mounting Hole Dimension d D h D1 d1 h1

M5 5.5 9.5 5.5 8 *4.2 4.5

M6 6.6 11 6.5 9.5 5.1 5.5

M8 8.5 14 8.5 11 6.8 6.5* Only for EN 1.4301 Equiv., d1 dimension is 4.3.

ThreadJIS B0203 Rc(PT)JIS B0202 G(PF): ISO 228-1 CompatibleANSI/ASME B.I.20.1-1983(NPT)

Mounting Holes

Mounting Holes

For details of recommended tapered male thread tightening torque and through pilot holes, see P.1224.

By inserting "G-" before part number, "PT Threads (Tapered Female Threads)" can be changed to "PF Threads (Parallel Female Threads)" in compliance with "JIS B 0202" (Unit Price remains the same). By inserting "G-" before part number, "PT Threads (Tapered Female Threads)" can be changed to "PF Threads (Parallel Female Threads)" in compliance with "JIS B 0202" (Unit Price remains the same).

∙ Standard Hole Shape

EMaterial of 70 Square is EN AW-6063 Equiv.

Usage

Type

M Material S Surface Treatment Max. Operating PressurePitch (P) Standard Pitch (P) Confi gurable30x35 Sq. 40 Sq. 60 Sq. 70 Sq. 30x40 Sq. 50 Sq. 70 Sq. 30x35 Sq. 40 Sq. 60 Sq.

HydraulicBMIS BMIF - BMIL - - - BMISP BMIFP - EN 1.0038 Equiv. Trivalent Chromate

20.6MPa≈210kgf/cm2 or less- BMIFR BMIFLR - - - - - BMIFRP BMIFLRP EN 1.4301 Equiv.-

- BMIFS - - - - - - - - EN 1.4401 Equiv.

Pneumatic- - - - BMIAF BMIAL BMIAB - - - EN AW-

5052 Equiv.-

1MPa≈10kgf/cm2 or less- - - - BMIAFA - - - - - Clear Anodize

Part Number- Q - R - S - G - K - P

Type Mounting Hole ChangeNumber of

Circuits

BMTFMPBMTACG-BMTAC

TT

233

---

Q1QM3QM3

---

R1R1R1

---

S1S1S1

---

G2G1G1

---

K2K1K1

- P30

(G Thread)

Part Number- R - S - G - K - P

Type Mounting Hole ChangeNumber of

Circuits

BMIAFBMIFRPG-BMIFRP

ZTZTZT

333

---

R1R2R2

---

S2S1S1

---

G2G2G2

---

K2K2K2

--

P25P25 (G Thread)

Part Number Rc (PT), NPT, M (Coarse) Selection Pitch P Number of Pitches

NTotal Number of

Q, R, S, G and K Threads A B E F X YMounting Hole

Type Mounting Hole Change Number of Circuits Q, R, S G, K Standard Confi gurable 1mm Increment M

Hydraulic (40 Sq.)

NA (Through)

T (Tapped)

ZT (Counterbore Tapped)

1 1 (1/8)

2 (1/4)

3 (3/8)

1N (NPT1/8)

2N (NPT1/4)

3N (NPT3/8)

2 (1/4)

3 (3/8)

4 (1/2)

2N (NPT1/4)

3N (NPT3/8)

4N (NPT1/2)

- - 0 5

40 40 35 20 20 7 M6

Pitch Standard

BMTFBMTFMBMTFRBMTFSBMTFC

Pitch Confi gurable

BMTFMPBMTFRP

2

4025~50

1 8

3 2 11

4 3 14

5 4 17

6 30~50 5 20

Hydraulic (60 Sq.) 1

2 (1/4)

3 (3/8)

4 (1/2)

6 (3/4)

2 (1/4)

3 (3/8)

4 (1/2)

6 (3/4)

- - 0 5

60 60 30 30 7.5 8 M8

Pitch Standard

BMTFL

BMTFLR

Pitch Confi gurable

BMTFLP

2

6035~60

1 8

3 2 11

4 3 14

5 4 17

6 40~60 5 20

Pneumatic (25 Sq.)

T (Tapped)

1

1 (1/8)

M3 (M3)

M4 (M4)

5 (M5)

1 (1/8)

M3 (M3)

M4 (M4)

5 (M5)

-

-

0 5

25 25 20 12.5 10 4 M5Pitch Standard

BMTAC

2

15

1 8

3 2 11

4 3 14

5 4 17

6 5 20

Pneumatic (30x40 Sq.)

NA (Through)

T (Tapped)

ZT (Counterbore Tapped)

11 (1/8)

2 (1/4)

5 (M5)

1N (NPT1/8)

2N (NPT1/4)

1 (1/8)

2 (1/4)

5 (M5)

1N (NPT1/8)

2N (NPT1/4)

-

-

0 5

30 40 20 20 7.5 7 M5Pitch Standard

BMTAFBMTAFA

2

30

1 8

3 2 11

4 3 14

5 4 17

6 5 20

Pneumatic (50 Sq.) 1

2 (1/4)

3 (3/8)

4 (1/2)

2 (1/4)

3 (3/8)

4 (1/2)

-

-

0 5

50 50 25 25 8.5 8.5 M8Pitch Standard

BMTALBMTALA

2

40

1 8

3 2 11

4 3 14

5 4 17

6 5 20

EBy inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BMTF) For ordering, see the Ordering Example.EFor Q, R, S, G and K, specify 1, 2, 3, 4, 5, 6, M3, M4, 1N, 2N, 3N or 4N indicated before ( ). ESingle Circuit is not available for Pitch Confi gurable Type.ESpecify the pitch taking into consideration the necessary dimensions for fi tting the couplings. EOnly 6 Circuit Type has an additional mounting hole at the midpoint of the overall length. (Except for 25 Sq.)

Part Number Rc (PT), NPT, M (Coarse) Selection Pitch P Number of Pitches

N

Total Number of

R, S, G and K ThreadsA B E F X Y

Mounting Hole

Type Mounting Hole Change Number of Circuits R, S G, K Standard Confi gurable 1mm Increment MHydraulic (30x35 Sq.)

NA (Through)

T (Tapped)

ZT (Counterbore Tapped)

1

1 (1/8)2 (1/4)

1 (1/8)2 (1/4)

- - 0 4

30 35 30 17.5 17 6 M5Pitch Standard

BMIS BMISP

2

3020~50

1 63 2 84 3 105 4 12

Ed1 dimension in ( ) is only applicable to EN 1.4301 Equiv. 6 25~50 5 14Hydraulic (40 Sq.) 1 1 (1/8)

2 (1/4)

3 (3/8)

1N (NPT1/8)

2N (NPT1/4)

3N (NPT3/8)

2 (1/4)

3 (3/8)

4 (1/2)

2N (NPT1/4)

3N (NPT3/8)

4N (NPT1/2)

- - 0 4

40 40 35 20 20 7 M6

Pitch Standard

BMIFBMIFRBMIFS

Pitch Confi gurable

BMIFPBMIFRP

2

4025~50

1 63 2 84 3 105 4 126 30~50 5 14

Hydraulic (60 Sq.) 1

2 (1/4)

3 (3/8)

4 (1/2)6 (3/4)

2 (1/4)

3 (3/8)

4 (1/2)6 (3/4)

- - 0 4

60 60 30 30 7.5 8 M8Pitch Standard

BMIFLRPitch Confi gurable

BMIFLRP

2

6035~60

1 63 2 84 3 105 4 126 40~60 5 14

Hydraulic (70 Sq.) 13 (3/8)

4 (1/2)6 (3/4)

6 (3/4)8 (1)

-

-

0 4

70 70 40 35 16.5 8 M8Pitch Standard

BMIL

260

1 63 2 84 3 10

Pneumatic (30x40 Sq.) 11 (1/8)

2 (1/4)

5 (M5)

1N (NPT1/8)

2N (NPT1/4)

1 (1/8)

2 (1/4)

5 (M5)

1N (NPT1/8)

2N (NPT1/4)

-

-

0 4

30 40 20 20 7.5 7 M5Pitch Standard

BMIAFBMIAFA

2

30

1 63 2 84 3 105 4 126 5 14

Pneumatic (50 Sq.) 1

2 (1/4)

3 (3/8)4 (1/2)

2 (1/4)

3 (3/8)4 (1/2)

-

-

0 4

50 50 25 25 8.5 8.5 M8Pitch Standard

BMIAL

2

40

1 63 2 84 3 105 4 126 5 14

Pneumatic (70 Sq.) 1

4 (1/2)6 (3/4)

4 (1/2)

6 (3/4)8 (1)

-

-

0 4

70 70 40 35 16.5 8 M8Pitch Standard

BMIAB

260

1 63 2 84 3 10

EBy inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BMIF) For ordering, see the Ordering Example.EFor R, S, G and K, specify 1, 2, 3, 4, 6, 8, 1N, 2N, 3N or 4N indicated before ( ). ESingle Circuit is not available for Pitch Confi gurable Type.ESpecify the pitch taking into consideration the necessary dimensions for fi tting the couplings. EOnly 6 Circuit Type has an additional mounting hole at the midpoint of the overall length.

Usage

Type

M Material S Surface Treatment Max. Operating PressurePitch (P) Standard Pitch (P) Confi gurable40 Sq. 60 Sq. 25 Sq. 30x40 Sq. 50 Sq. 40 Sq. 60 Sq.

Hydraulic

BMTF BMTFL - - - - BMTFLPEN 1.0038 Equiv.

Trivalent Chromate

20.6MPa≈210kgf/cm2 or lessBMTFM - - - - BMTFMP - Electroless Nickel Plating

BMTFR BMTFLR - - - BMTFRP - EN 1.4301 Equiv. -

BMTFS - - - - - - EN 1.4401 Equiv. -

BMTFC - - - - - - Brass -1MPa≈10kgf/cm2 or less

Pneumatic- - BMTAC BMTAF BMTAL - - Aluminum Alloy 5000

series-

- - - BMTAFA BMTALA - - Clear Anodize

EBMTFLRP (EN 1.4301 Equiv., 60 Sq., Pitch Confi gurable) is available on our website.