TECHNICAL INFORMATION LMS531 Security Outdoor Laser Measurement Sensors Supplement to the operating instructions of LMS5xx product family. Valid for commissioning according to Security Applications.

Upload: others

Post on 23-Mar-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LMS531 Security Outdoor Laser Measurement Sensors

T E C H N I C A L I N F O R M A T I O N

LMS531 Security OutdoorLaser Measurement Sensors

Supplement to the operating instructions of LMS5xx product family. Valid for commissioning according to Security Applications.

Page 2: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 2

Content 0. Introduction .................................................................................................................................... 3 1. Depth of Information ...................................................................................................................... 3 2. Software-Release Status and Order Information .......................................................................... 4

LMS 531-10xxx – Security Outdoor ........................................................................................... 4 2.1. Software Access Rights ............................................................................................................. 4 2.2.

3. Product Description LMS531 ......................................................................................................... 4 Factory Default Settings ............................................................................................................ 5 3.1. Evaluation Cases....................................................................................................................... 6 3.2. Device signals ........................................................................................................................... 6 3.3. Teach-In functionality ................................................................................................................ 8 3.4. Easy Teach ............................................................................................................................. 10 3.5. Obstruction Protection Activated .............................................................................................. 16 3.6. Obstruction is signed at LED Q2 .............................................................................................. 16 3.7. Front panel - display activation ................................................................................................ 16 3.8. Automatic field adaption (PRO devices only) ........................................................................... 16 3.9.

4. SOPAS ET for Security application ............................................................................................. 18 Security specific user labels .................................................................................................... 18 4.1. Changeable password ............................................................................................................. 18 4.2. Parameterization modes .......................................................................................................... 19 4.3. Quickstart page ....................................................................................................................... 20 4.4. Default parameter Security ...................................................................................................... 22 4.5.

5. Electrical Connectivity ................................................................................................................. 24 LMS531 Lite ............................................................................................................................ 24 5.1. LMS531 PRO .......................................................................................................................... 25 5.2.

6. Electrical Installation .................................................................................................................... 27 7. Technical Specifications .............................................................................................................. 31

Page 3: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 3

0. Introduction

The LMS531 laser measurement sensor is a dedicated unit with a number of specialized features, both hardware and software, for the security industry. This unit is based on the LMS5xx Series.

This document contains all major new features. For additional information about the LMS5xx Series please refer to the LMS5xx Operating Instructions manual (P/N 8013796, issue VC01 of 2012-04-18) on

the SICK product page www.mysick.com/en/lms5xx. In this document the LMS531 Lite and PRO versions are addressed. All features described are common to both versions except otherwise mentioned.

1. Depth of Information

Mandatory and in addition the LMS5xx operating instructions (P/N 8013796, issue VC01 of 2012-04-18) has to be used. These operating instructions contain the following information: - Product description LMS - Safety Instructions - Maintenance - Fault, error diagnosis and troubleshooting - Technical data and dimensional drawings - Ordering information - Conformity and approval Planning and using laser measurement systems such as the LMS also require specific technical skills which are not detailed in this documentation. Further information on the LMS531 is available from SICK AG, Division identification & Measuring, and on the SICK product page www. mysick.com/en/lms5xx. Copyright Copyright © 2014 SICK AG Waldkirch

Page 4: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 4

2. Software-Release Status and Order Information

The corresponding sensors with their dedicated order numbers will have own special firmware versions. The dedicated access levels are also described in this document.

LMS 531-10xxx – Security Outdoor 2.1.

Device / Software / Tool Function Version

LMS531-11100 Lite (P/N 1055376) Laser Measurement Security Outdoor (RAL7032-grey)

Firmware V31.39

LMS531-10100 PRO (P/N 1067356) Laser Measurement Security Outdoor (RAL7032-grey)

Firmware V31.39

Device description LMS531 Device specific software module SOPAS ET

From V31.39/ 2013-11-20

SOPAS ET Configuration software V2.38.2 Build 5824

NOTE: Older versions of LMS531 Lite can be firmware upgraded to the newer version V31.39, however all configurations will be lost. The new LMS531 Lite will need to be re-programmed again. The old Lite configuration will not be compatible with the new Firmware.

Software Access Rights 2.2.

Software access to the LMS531 is password protected. As supplied the following passwords are defined:

Default label LMS531 Security Default password

Operator Operator No password required

Maintenance Authorized Operator main

Authorized Client Integrator client

A password is not defined for the Operator user level as supplied. Only on the Integrator level the system can be set up and therefore the parameters and system settings can be changed.

3. Product Description LMS531

This chapter informs about the special characteristics of a LMS531 laser measurement sensor. There is a description about the construction, functionality in particular with different mode of operations. Please read this chapter carefully before installing and commissioning and using the device.

Qty Components Comment

1 LMS531 Hardware

1 Notes on Device with electrical circuit diagram for getting started.

Included in the LMS531 packaging

1 DVD “Manual & Software Content see also LMS5xx operating instructions

Page 5: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 5

Qty Components Comment

Identification & Measuring” manual

Factory Default Settings 3.1.

3.1.1. Basic Parameters at Detection of Objects

The LMS531 scans with a scanning frequency of 25, 35, 50, 75 or 100 Hz according to versions or with an angular resolution from 0.166° to 1°. At a higher scanning frequency or a finer angular resolution the LMS531 supplies more measured values. There are several valid combinations of scan frequency and angular resolution possible. These can be selected in the SOPAS ET configuration software.

3.1.2. Filter

The LMS531 has digital filters for the pre-processing and optimization of the measured distance values. You can configure a fog filter, multiple echo filters or a filter for interference suppression (airborne particles). Fog filter The fog filter suppresses possible glare due to fog. The LMS531 becomes less sensitive in the near range (up to approx. 7 m) with the fog filter.

Echo filter

If echo pulses are reflected by several objects during a measurement (incident on drops of rain, glass surfaces, edges etc.) with a maximum of up to five echoes (PRO), the echo filter can be selected to give out only the first echo, all echoes or the last echo received.

Particle filter

The particle filter can be used in dusty surroundings or in case of rain or snow to filter out interference due to particles of dust, rain drops, snowflakes etc.

Important

The particle filter is an application filter. It acts on the field application, not on the measured value output.

Due to the particle filter, the reaction to an object in the evaluation field or an infringement of the contour is delayed by the time for a scan. The response time set for the pixel evaluation, blanking and contour evaluation strategies is not changed as a result.

3.1.3. Measured value output

For the measured value output, the LMS531 can supply the measured values to one of the communication interfaces. For further information, please refer to the LMS5xx Operation Instructions.

The LMS531 Lite transfer communication speed for the measured values is limited to 1Hz.

3.1.4. Field Application

With the aid of the integrated field application, the LMS531 PRO evaluates up to 10 evaluation fields within its scan area. Using the field application, you can e.g. implement systems for building surveillance or for access monitoring.

As supplied nine evaluation fields with pre-configured parameters are available. You can change and adapt the size and shape of all nine evaluation fields to suit your needs. These evaluation fields are

Page 6: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 6

already configured with evaluation cases for the pixel evaluation with blanking and linked to the alarm output. You can also configure a 10th field. This field is used for tamper protection.

Important

The tamper protection function is only possible with the 10th field (LMS531 PRO). The 10th field cannot be used as a monitoring field.

The LMS531 Lite evaluates up to 4 evaluation fields within its scan area. The tamper protection function is only possible with the 4th field. The 4th field cannot be used as a monitoring field.

Each field can only be used once in one evaluation case. If the field needs to be used in more than one evaluation case it must be duplicated (the copy field function can be used).

Evaluation Cases 3.2.

An evaluation case defines which output field is evaluated in which way and on which output it acts. You can configure up to ten evaluation cases (LMS531 PRO) or up to four evaluation cases (LMS531 Lite), all configured evaluation cases are active simultaneously. Only one field can be used per evaluation case.

For each evaluation case you configure in SOPAS ET:

• Inputs that activate an evaluation case, if necessary

• The evaluation strategy

• The evaluation field

• The output on which the evaluation case acts

• The response time of the output

Device signals 3.3.

3.3.1. Inputs

The LMS531 contains 3 different operating modes. The different operating modes can be activated by switching 1st and 2nd digital inputs.

1st

input 2nd

input Operating mode

0 V 0 V Armed (only if 2nd

input = 0 V = Walk test inactive)

24 V 0 V Disarmed (only if 2nd

input = 0 V = Walk test inactive)

0 V 24 V Walk test active

24 V 24 V Walk test active

- 1st input: switching between “ARMED” and “DISARMED”

- 2nd input: switching between “WALK TEST” active and inactive

Meaning of each mode: - ARMED: In this mode the full front panel (LEDs, display and USB interface) will be inactive. Field

infringements will not be visible on the LEDs. If a field infringement exists, the alarm output switches on and an internal alarm memory will be set. The alarm memory will be visible in the mode “Disarmed”.

Page 7: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 7

- DISARMED: In this mode only the “Q1” LED will be set if during mode “Armed” the alarm memory was set. If a field infringement exists in this operation mode, the alarm output switches but the LEDs are inactive.

- WALK TEST: The Front panel is active and field infringement will be displayed on the “Q1” LED and alarm output switches. The 2nd input has a higher priority than 1st input. So if “Walk test” is active the “Armed/Disarmed” mode is disregarded.

3.3.2. Outputs

All evaluation cases are directly linked to the alarm output. The LMS 531 has two (Lite) or four (PRO) relay outputs. The configuration of the outputs is as follows:

Output 1: Alarm (Lite, PRO) (Relay)

Output 2: Error (Lite, PRO) (Relay)

Output 3: Sabotage (Lite) (Digital)

Output 3: Disqualification (PRO) (Relay)

Output 4: Sabotage (PRO) (Relay)

The relay outputs can be used as volt-free outputs. Output 1 (Alarm) of Lite and PRO and Output 4 (Sabotage) of PRO can be resistance monitored outputs.

3.3.3. Day/Night switching (PRO device)

The 3rd input can be used to activate the either day or night Evaluation Cases.

3rd

input Day/Night switching

0 V Evaluation fields which are active at day are monitored

24 V Evaluation fields which are active at night are monitored

Page 8: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 8

3.3.4. Alarm signal

All existing fields are connected by logic “OR” to digital Output 1 (Alarm). The Restart time can be parameterized. Under the SOPAS ET “Standard Mode” the Alarm message is programed to the Output 1 (Alarm) and cannot be changed. The duration of the switched alarm output can be set in different steps:

1 second

3 seconds

10 seconds The factory default set of the parameter is 3 seconds. Under the SOPAS “Expert Mode” the Alarm message can be programmed to any output.

3.3.5. Error signal

If there is an error with the device this signal will activate. This is equivalent to the “Device_Ready” functionality of the standard devices. Under the SOPAS ET “Standard Mode” the Error message is programmed to the Output 2 (Error) and cannot be changed. The duration of the switched Error output can be set in different steps:

1 second

3 seconds

10 seconds The factory default set of the parameter is 3 seconds. Under the SOPAS ET “Expert Mode” the Error message can be programed to any output.

Teach-In functionality 3.4.

3.4.1. Tamper protection contour

The Field editor has an additional Teach-In mode called “Tamper protection contour”.

This Tamper Protection Contour field is designed to detect whether the front lens of the LMS531 has been covered or the LMS531 has been moved from its original position. Basically it creates a contour as a reference field starting always from the LMS531 and predefined in the “standard” mode to Field 10. In “Expert” Mode this field can be changed under the “Evaluation Case”

Page 9: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 9

section and the Evaluation Strategy must be selected under “Contour”.

In the following settings, the parameter “Distance” controls how far the teach points are away from contour (positive distance). In the above picture the offset distance to the contour is 100 mm. This “Distance” setting allows some tolerances in case of vibrations on the LMS531 or the target. If the LMS531 is also rotated or moved from its original position and the new target exceeds the limit of the Tamper protection contour (green line on the above picture) the output 1 “Alarm” will be triggered.

3.4.2. Validation Checking

Tampering within the monitored field areas is prevented with this function. It is used for final testing and prevents incorrect set-up of the monitoring fields. This function will validate that all the programmed fields and contours of the LMS531 are clear from any obstacle or shadows and are fully visible from the LMS531’s position. This operation must be performed with the LMS531 connected and online. The TEACH-IN VALIDITY AREA function must be run once at the end. Under the “Expert” Mode this function can be found under the main menu “Parameters” “Security” or directly on the “Quick Start” page in the “Standard” Mode.

Page 10: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 10

The following status can be indicated:

Pending / Open Validity check has not yet been undertaken (new fields have been defined, existing fields have been modified or deleted).

Invalid Taught-in contour is invalid (e.g. half of the beams for a field are invalid).

Valid Contour has been successfully taught-in. Validity signifies that every laser beam in every angular segment is checked for valid and stable measured values. This test is however only performed for the angular areas in which monitoring fields have been defined. In this way it is ensured that sufficient measured values are available that the LMS531 can evaluate.

During the validity check all set-up fields are checked for validity. If all fields are valid, the fault output is cleared and as a result the fault signal removed. If the monitoring fields configured are not found to be valid, the fault output remains activated and generates a fault message. In the SOPAS ET user interface the outputs are changed from orange to gray. Manipulation within the monitored field areas is prevented with this function. If a manipulation (masking) lasts by minimum of 10 seconds an error is triggered. Falls off the error the error signal turns off and the error output of the LMS531 turns clear again. Important If new fields are defined, or existing fields are modified or deleted, the validity check must be performed again. If this action is not undertaken by the installer, the fault output remains active.

Easy Teach 3.5.

The Easy Teach function will allow the customer to design a field by physically moving in front of the LMS531 in order to “draw” the desired field. This new field must be within the boundaries of a predefined field acting as a region of interest during the “draw” field. This functionality can be actioned (start/stop) by the digital Input 4. There are three modes available for Easy Teach – these are INACTIVE, LITE (available for PRO and LITE devices) and PRO (just available for PRO device) and may be chosen by users of level Integrator and above.

Page 11: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 11

Generally the automated field generation is started by setting input 4 active and stopped when it goes inactive.

4th

input Activation Easy Teach

0 V Easy Teach Teach-In stopped

24 V Easy Teach Teach-In started

The parameter “Minimum duration” defines the minimum time how long the teaching process will last once the trigger (Input 4) is activated. This parameter will allow the LMS531 to do an Easy Teach without the need to hold the trigger input, only a short single pulse will be required. NOTE: If the user has configured the Input Delay value, the length of the pulse for Easy Teach trigger must be longer.

During teaching process the LED ‘Q2’ is switched on at the device front panel. After finishing, the LED ‘Q2’ flashes for 10 seconds and the field is stored permanently.

3.5.1. Easy Teach ‘Lite’

Only one field can be defined with the Easy Teach Lite mode. This is done by setting angle range, field number, field name, mode and minimum distance(s) to the contour of the field. This mode has 2 functions: Field Contour or Reference Contour.

Easy Teach Lite (Field contour)

Page 12: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 12

Easy Teach Lite (Reference contour)

3.5.2. Easy Teach ‘PRO’ (PRO devices only)

In the PRO mode up to five Easy Teach fields can be defined for automated field generation over the digital input (see Image 1). These fields require defined background fields as patterns or region of interest. Background / Pattern fields also work as limits for the Easy Teach field. Each Easy Teach field can have its own Pattern field. As a first step, the customer must create one or more Pattern fields defining the maximum borders of the fields, which should be generated in SOPAS ET Field Editor. Next, each Easy Teach fields to be created must be defined or configured. Each Easy Teach field has its own parameters. See image below. All the activated fields will be teach in together once the input 4 is activated, as described earlier.

Page 13: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 13

Image 1: Easy Teach Pro

Page 14: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 14

Example for mode “Field contour”:

Easy Teach field (green) with 200 mm distance to contour.

Some contour values are shorter than the reference field values (grey). At this angular range the start- and endpoints of Easy Teach field (yellow) have the same distance. Due to active Obstruction Protection the Easy Teach field is infringed (distance is shorter than field start points).

Example for mode “Reference contour”:

In this case the contour is free (green).

Page 15: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 15

Reference field values are closer to contour values like Teach-In parameters. At this angular range the start- and endpoints of Easy Teach field (yellow) have the same distance like the reference field points.

Some contour values are longer than the reference field values (gray). At this angular range the endpoints of Easy Teach field (yellow) have the same distance like the reference field points.

Some contour values are longer than the reference field values (gray). At this angular range the start- and endpoints of Easy Teach field (yellow) have the same distance like the reference field points.

Some contour values are shorter than the reference field values (gray). At this angular range the start- and endpoints of Easy Teach field (yellow) have the same distance like the reference field points.

Some contour values are invalid. At this angular range the Easy Teach field endpoints have the same distance like the reference field points.

Page 16: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 16

Obstruction Protection Activated 3.6.

For each Evaluation Case the “Obstruction Protection” is active by default.

Obstruction is signed at LED Q2 3.7.

If during operation mode “Armed” an obstruction occurs (covering device, removing lens cap) it will be signed by flashing LED Q2 during the operation mode “Disarmed”.

Front panel - display activation 3.8.

Front panel display can be enabled/disabled depending on the operation mode, i.e. it will be disabled in ‘armed’ mode and enabled in ‘disarmed’ and ‘setup’ mode.

Automatic field adaption (PRO devices only) 3.9.

3.9.1. The underlying scenario

Page 17: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 17

This feature has been designed for some particular situations. If the LMS531 is setup to perform a façade monitoring, as an example, there will be a field looking down to the ground level. In the case of snow falling, the level of the snow on the ground will slowly raise to a point where it could infringe the monitoring field.

With the Automatic Field Adaption feature the field will adapt automatically to the shape of the slow growing snow, as described in the example.

3.9.2. Configuration

An evaluation case can now be configured so that its linked field will be automatically adapted under certain circumstances, for example grass, snow growing, etc. In the parameterization assistant of an evaluation case the following settings will be shown:

- Enable/disable automatic field adaption

- Set output to signal field adaption

- Set max. possible velocity which determines if field adaption is valid/possible

With this function activated the LMS531 will evaluate the edge of the field for any slow intrusion into the setup field.

The speed of the intrusion is determined by the Velocity setting.

If the speed is exceeded, then the selected evaluation output will be triggered.

When snow or grass is starting to “touch” the field the Automatic Field Adaption will trigger. When this triggering is happening the LMS531 can signalise this triggering via the selected Output.

3.9.3. Adaption of field points

The adaption of field points is triggered by at least one scan point “touching” the edge of the field. The following field points are then adapted:

1) All field points, which “touch” the edge of the field and simultaneously do not exceed the velocity (Attention: the velocity is only considered if the field is adapted towards the LMS531)

2) All the surrounding field points in the near area will be adapted to smoothen the shape. NOTE:

Page 18: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 18

If a point appears in the middle of the field, not on the edges, it will be considered as an intrusion and the alarm output will be triggered.

4. SOPAS ET for Security application

Related SOPAS ET Version is V2.38.2 Build 5824.

Security specific user labels 4.1.

For security application the Standard SOPAS ET user labels are renamed. In case of Security device the labels are:

Default Security

Operator Operator

Maintenance Authorized Operator

Authorized Client Integrator

The meaning of the Security levels are: Operator: - No password required

- Only reading rights.

- Not all parameters are visible.

Authorized Operator: - Only reading rights.

- Not all parameters are visible.

- Can change the password for this user level.

NOTE: Functionality between Operator and Authorized Operator is the same in this software version

Integrator: - Access to all parameters which are needed to startup a Security application.

- Can change the password for this user level.

Changeable password 4.2.

Via SOPAS ET it is possible to change the password of the current user level. A higher user level can change a lower user level. For example, “Integrator” level could change the “Authorized Operator” level.

Page 19: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 19

NOTE: If “Integrator” user level password is changed and lost, please contact SICK. Default passwords are:

Default label LMS531 Security Default password

Operator Operator No password required

Maintenance Authorized Operator main

Authorized Client Integrator client

Parameterization modes 4.3.

The LMS531 can be parameterized via a simple mode called “Standard” or via a more detailed view mode called “Expert”. The extension of device tree depends on the selected mode.

Standard Mode: Quickstart page and Evaluation Monitor is visible

Expert Mode: Standard LMS500 tree is visible

If the mode is changed from “Expert” to “Standard” the user will be asked if the Security defaults should be set. It’s recommended to click YES.

NOTE: If the Security defaults could not be set it is possible that the settings on the Quickstart page are inconsistent with the current device settings (e.g. if in “Expert” mode settings of one Evaluation Case was modified and the object size is not the same for all fields).

Page 20: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 20

Quickstart page 4.4.

The Quickstart page contains all parameters which are required for a customer to parameterize a Standard Security application.

Surveillance Areas

The PRO version contains 9 predefined areas and only 3 areas in the Lite version.

Field 1: rectangle 40 m x 20 m (symmetrical around 90° beam)

Page 21: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 21

Field 2-9 (Lite: 2-3): rectangle 40 cm x20 cm (symmetrical around 90° beam)

Existing predefined fields can be modified or deleted and new ones created. The parameterization is the same as standard LMS500 units. With the Security defaults set all fields have the same responding properties. In the Security application each field has an activation state which depends on the level of the digital output number 3.

Level 3rd

output Device mode

0 V Day

24 V Night

0 V/24 V (Don’t care) Always

This parameter is equivalent to the settings of the input number 3 at Evaluation Case parameterization.

Page 22: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 22

Responding properties

These settings are valid for all existing fields.

NOTE: The minimum object size which should be detected cannot be guaranteed in the complete scan range. So the object size is depending on the maximum field distance. Therefore a parameterized field must be verified with the corresponding object size setting.

Alarm signal All existing fields are connected by logical “OR” to digital output 1. Output’s number is fixed. Restart time can be parameterized. Error signal Output number is fixed. Restart time can be parameterized.

Default parameter Security 4.5.

Some default parameter settings are changed from the standard LMS500 for Security behavior.

Group Parameter Property

Responding Properties (Quickstart)

Object size 40 mm

Tripping Time 240 ms

Alarm Signal (Quickstart) Power-On-Time 3 s

Error Signal (Quickstart) Power-On-Time 3 s

Evaluation Fields 9 predefined rectangle Fields (PRO) 3 predefined rectangle Fields (Lite)

Field1: rectangle 40 m x 20 m (symmetrical around 90° beam)

Field 2-9 (Lite: 2-3): rectangle 40 cm x 20 cm (symmetrical around 90° beam)

Evaluation Cases (Expert Mode)

9 predefined Evaluation Cases

3 predefined Evaluation Cases

PRO device Lite device

LMS531 PRO:

Evaluation Case No.1 – No.9: Strategy Blanking

Evaluation Case No.10: Strategy Contour (Obstruction Protection is always active)

LMS531 LITE:

Evaluation Case No.1 – No.3: Strategy Blanking

Evaluation Case No.4: Strategy Contour (Obstruction Protection is always active)

Response Time 240 ms

Object Size 40 mm

Connected Field Evaluation Case No.1 is connected to field No.1; Evaluation Case No.2 is connected

Page 23: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 23

Group Parameter Property

to field No.2 and so on.

Connected Output No. 1 (Alarm output)

Digital Outputs (Expert Mode)

Function Output 1: Application (Alarm o/p) Output 2: Device Ready (Error o/p)

Logic Type Output 1: Active Low Output 2: Active High

Restart Output 1: Time Output 2: Time

Restart Delay Output 1: 3 s Output 2: 3 s

Page 24: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 24

5. Electrical Connectivity

LMS531 Lite 5.1.

Pin Signal Function

1 24 V SYS Power supply sensor

2 24 V HEAT Power supply heater

3 GND SYS Ground power supply sensor

4 Reserved Do not use

5 GND HEAT Ground power supply heater

Tab.: LMS531 Lite/PRO: pin assignment of the "Power" connection

LMS531 Lite "Power" connection M12x5 plug, A-type encoded

Pin Signal Function

1 A/DA Armed/Disarmed

2 WT Walk Test

3 Reserved Do not use

4 Reserved Do not use

5 Reserved Do not use

6 Reserved Do not use

7 Easy Teach Tech in

8 IN GND Ground inputs

Tab.: LMS531 Lite: pin assignment of the "Inputs" connection

LMS531 Lite "Inputs" connection M12x8 plug, A-type encoded

Pin Signal Function

1 Alarm 1 Alarm output 1

2 Alarm 2 Alarm output 2

3 Alarm R Alarm output R

4 Alarm R Alarm output R

5 Error 1 Error output 1

6 Error 2 Error output 2

7 Sabotage Sabotage output

8 GND Ground sabotage output

Tab.: LMS531 Lite: pin assignment of the "Outputs" connection

LMS531 Lite "Alarms" connection M12x8 socket, A-type encoded

Page 25: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 25

Pin Signal Function

1 TX+ Transmit+

2 RX+ Receive+

3 TX- Transmit-

4 RX- Receive-

Tab.: LMS531 Lite/PRO: pin assignment of the "Ethernet" connection

LMS531 Lite "Ethernet" connection M12x4 socket, D-type encoded

LMS531 PRO 5.2.

Pin Signal Function

1 24 V SYS Power supply sensor

2 24 V HEAT Power supply heater

3 GND SYS Ground power supply sensor

4 Reserved Do not use

5 GND HEAT Ground power supply heater

Tab.: LMS531 Lite/PRO: pin assignment of the "Power" connection

LMS531 PRO "Power" connection M12x5 plug, A-type encoded

Pin Signal Function

1 A/DA -IN1 Armed/Disarmed

2 RD-/RxD RS-422/232

3 IN GND Ground inputs

4 RS RND Ground serial data

5 D/N -IN3 Day/Night

6 WR -IN2 Walk test

7 TD-/TxD RS-422/232

8 Easy Teach -IN4 Teach in

9 RD+ RS-422

10 TD+ RS-422

11 CAN_L CAN bus

12 CAN_H CAN bus

Tab.: LMS531 PRO: pin assignment of the "Inputs" connection

LMS531 PRO "Inputs" connection M12x12 plug, A-type encoded

Page 26: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 26

Pin Signal Function

1 Out1_a Alarm output 1

2 Out4_a Sabotage output 1

3 Out1_b Alarm output 2

4 Out1R_ Alarm output R

5 Out2_a Error output 1

6 Out1R_b Alarm output R

7 Out3_a Disqualification output 1

8 Out2_b Error output 2

9 Out4_b Sabotage output 2

10 Out3_b Disqualification output 2

11 Out4R_a Sabotage R output 1

12 Out4R_b Sabotage R output 2

Tab.: LMS531 PRO: pin assignment of the "Alarms" connection

LMS531 PRO "Alarms" connection M12x12 socket, A-type encoded

Pin Signal Function

1 TX+ Transmit+

2 RX+ Receive+

3 TX- Transmit-

4 RX- Receive-

Tab.: LMS531 Lite/PRO: pin assignment of the "Ethernet" connection

LMS531 PRO "Ethernet" connection M12x4 socket, D-type encoded

Page 27: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 27

6. Electrical Installation

Please refer to the LMS5xx Operation Instructions for additional information. The color coding of the SICK cables together with the functionality is shown below:

Page 28: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 28

Easy Teach

Reserved

WT

Page 29: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 29

“Alarm” connection on the LMS531 PRO

Sabotage

Brown = Alarm 1

Blue = Sabotage 1

White = Alarm 2

Green = Alarm R

Pink = Error 1

Yellow = Alarm R

Black = Disqualification 1

Grey = Error 2

Red = Sabotage 2

Violet = Disqualification 2

Grey/Pink = SabotageR

Red/Blue = SabotageR

Page 30: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 30

“Data” connection on the LMS531 PRO

Brown = A/DA

Blue = RD-/RxD

White = GND IN

Green = GND RS

Pink = D/N

Yellow = WT

Black = TD-/TxD

Grey = Easy Teach

Red = RD+

Violet = TD+

Grey/Pink = CAN_L

Red/Blue = CAN_H

Page 31: LMS531 Security Outdoor Laser Measurement Sensors

Technical Information

LMS531 Laser Measurement Sensors

8017289/2014-04-01 © SICK AG · Germany · All rights reserved · Subject to change without notice 31

7. Technical Specifications

For information on the Technical Specifications of the LMS531, please refer to the Operation Instruction document (P/N 8013796, issue VC01 of 2012-04-18). The only specific technical information for the LMS531 is the use of relay outputs instead of digital outputs. For technical specification on the relays used, please refer to the information below:

Relays Outputs LMS531 Min Typ Max Unit

Number of relays Lite 2

PRO 4

Load voltage peak AC 28 V

DC 40 V

Continuous load current At 25°C 1 A

Peak load current At 25°C,100 ms, non-repetitive 3 A

On resistance 0.34 0.7 Ω

Output capacitance 450 pF

Input/Output isolations voltage 60 V

Turn on time 1.3 5 ms

Turn off time 0.1 0.5 ms

Max. switching frequency 5 Hz

Continuous load capacity SabotageR and AlarmR 1 A

Digital Output LMS531 Lite Min Typ Max Unit

Number of digital outputs (Sabotage) 1

Voltage drop load 2 V

Switching current 140 mA

Current limit (after 5 ms at 25°C) 100 mA

Power-up delay Negligible

Switch-off time 0.8 ms 2 ms

Page 32: LMS531 Security Outdoor Laser Measurement Sensors

SICK AG | Waldkirch | Germany | www.sick.com

8017

289/

2014

-04-

01 ∙

JC_8

M ∙

A4 4

c in

t42 Australia

Phone +61 3 9457 0600 1800 334 802 – tollfreeE-Mail [email protected]

Belgium/LuxembourgPhone +32 (0)2 466 55 66E-Mail [email protected]

BrasilPhone +55 11 3215-4900E-Mail [email protected]

CanadaPhone +1 905 771 14 44E-Mail [email protected]

Česká republikaPhone +420 2 57 91 18 50E-Mail [email protected]

ChinaPhone +86 4000 121 000E-Mail [email protected] +852-2153 6300E-Mail [email protected]

DanmarkPhone +45 45 82 64 00E-Mail [email protected]

DeutschlandPhone +49 211 5301-301E-Mail [email protected]

EspañaPhone +34 93 480 31 00E-Mail [email protected]

FrancePhone +33 1 64 62 35 00E-Mail [email protected]

Great BritainPhone +44 (0)1727 831121E-Mail [email protected]

IndiaPhone +91–22–4033 8333E-Mail [email protected]

IsraelPhone +972-4-6881000E-Mail [email protected]

ItaliaPhone +39 02 27 43 41E-Mail [email protected]

JapanPhone +81 (0)3 3358 1341E-Mail [email protected]

MagyarországPhone +36 1 371 2680E-Mail [email protected]

NederlandPhone +31 (0)30 229 25 44E-Mail [email protected]

Norge Phone +47 67 81 50 00E-Mail [email protected]

ÖsterreichPhone +43 (0)22 36 62 28 8-0E-Mail [email protected]

PolskaPhone +48 22 837 40 50E-Mail [email protected]

RomâniaPhone +40 356 171 120 E-Mail [email protected]

RussiaPhone +7-495-775-05-30E-Mail [email protected]

SchweizPhone +41 41 619 29 39E-Mail [email protected]

SingaporePhone +65 6744 3732E-Mail [email protected]

SlovenijaPhone +386 (0)1-47 69 990E-Mail [email protected]

South AfricaPhone +27 11 472 3733E-Mail [email protected]

South KoreaPhone +82 2 786 6321/4E-Mail [email protected]

SuomiPhone +358-9-25 15 800E-Mail [email protected]

SverigePhone +46 10 110 10 00E-Mail [email protected]

TaiwanPhone +886 2 2375-6288E-Mail [email protected]

TürkiyePhone +90 (216) 528 50 00E-Mail [email protected]

United Arab EmiratesPhone +971 (0) 4 88 65 878E-Mail [email protected]

USA/MéxicoPhone +1(952) 941-6780 1 (800) 325-7425 – tollfreeE-Mail [email protected]

More representatives and agencies at www.sick.com