itk earth · 2020. 9. 18. · the mantle (thickness ~2900/cwi) and the crust (thickness ~5 to...
TRANSCRIPT
ITK
Earth
I L:~*»..4ril
Iy* rning Earthquake Design and Construction
A**
^6-^s5
Department of Civil EngineeringIndian Institute of TechnologyKanpur
Building Materials and Technology Promotion CouncMinistry of Urban Development & Poverty AlleviationGovernment of India
New Delhi•
***!
IITK hmlpc
Earthquake
TipsLearning
Part 1
Earthquake Design and Construction
Department of Civil EngineeringIndian Institute of Technology KanpurKanpur
Building Materials and Technology Promotion CouncilMinistry of Urban Development & Poverty AlleviationGovernment of India
New Delhi
M I
_l_
—r—72E
_l_WE ME
I
90'E
_J_96E
_l_
IndiaSeismic Zones
O SlatelUnion Temlory
Ci Dislricls
Source Seismic Zones based on Bureau
of Indian Standards[IS:1893(Part-1)-2002Jand Base Map as perdigitised dataofSurvey of India
—r—90E
IITK - ErnieEarthquake Tip
What Causes Earthquakes?
The Earth and its Interior
Long time ago, a large collection of materialmasses coalesced to form the Earth. Large amount ofheat was generated by this fusion, and slowly as theEarth cooled down, the heavier and denser materialssank to the center and the lighter ones rose to the top.The differentiated Earth consists of the Inner Core
(radius ~129(U»i), the Outer Core (thickness 4-2200Jtm),the Mantle (thickness ~2900/cwi) and the Crust(thickness ~5 to 40Ar//r). Figure 1 shows these layers.The Inner Core is solid and consists of heavy metals(e.g., nickel and iron), while the Crust consists of lightmaterials (e.g., basaltsand granites). The Outer Core isliquid in form and the Mantle has the ability to flow.At the Core, the temperature is estimated to be~2500°C, the pressure ~4 million atmospheres anddensity -13.5 gm/cc; this is in contrast to ~25°C, 1atmosphere and 15gm/cc on the surface of the Earth.
Figure 1:Inside the Earth
The Circulations
Convection currents develop in the viscousMantle, because of prevailing high temperature andpressure gradients between the Crust and the Core,like the convective flow of water when heated in a
beaker (Figure 2). The energy for the abovecirculations is derived from the heat produced fromthe incessant decay of radioactive elements in therocks throughout the Earth's interior. These convectioncurrents result in a circulation of the earth's mass; hotmolten lava comes out and the cold rock mass goesinto the Earth. The mass absorbed eventually meltsunder high temperature and pressure and becomes apart of the Mantle, only to come out again fromanother location, someday. Many such localcirculations are taking place at different regionsunderneath the Earth's surface, leading to differentportions of the Earth undergoing different directionsof movements along the surface.
Figure 2:Local Convective Currents in the Mantle
LearningEarthquake Design
Construction
Plate Tectonics
The convective flows of Mantle material cause the
Crust and some portion of the Mantle, to slide on thehot molten outer core. This sliding of Earth's masstakes place in pieces called Tectonic Plates. The surfaceof the Earth consists of seven major tectonic plates andmany smaller ones (Figure 3). These plates move indifferent directions and at different speeds from thoseof the neighbouring ones. Sometimes, the plate in thefront is slower; then, the plate behind it comes andcollides (and mountains are formed). On the otherhand, sometimes two plates move away from oneanother (and rifts are created). In another case, twoplates move side-by-side, along the same direction orin opposite directions. These three types of inter-plateinteractions are the convergent, divergent and transformboundaries (Figure 4), respectively. The convergentboundary has a peculiarity (like at the Himalayas) thatsometimes neither of the colliding plates wants to sink.The relative movement of these plate boundaries variesacross the Earth; on an average, it is of the order of acouple to tens of centimetersperyear.
Figure 3:^Major Tectonic Plateson the Earth's surface
IITK-BMTPC Earthquake Tip 2
How the ground shakes?
Support
^^Figure3; Schematic of Early Seismograph __^r
One such instrument is required in each of the twoorthogonal horizontal directions. Of course, formeasuring vertical oscillations, the string pendulum(Figure 3) is replaced with a spring pendulumoscillating about a fulcrum. Some instruments do nothave a timer device (i.e., the drum holding the chartpaper does not rotate). Such instruments provide onlythe maximum extent (or scope) of motion during theearthquake; for this reason they are called seismoscopes.
The analog instruments have evolved over time,but today, digital instruments using modern computertechnology are more commonly used. The digitalinstrument records the ground motion on the memoryof the microprocessor that is in-built in the instrument.
Strong Ground MotionsShaking of ground on the Earth's surface is a net
consequence of motions caused by seismic wavesgenerated by energy release at each material pointwithin the three-dimensional volume that ruptures atthe fault. These waves arrive at various instants of
time, have different amplitudes and carry differentlevels of energy. Thus, the motion at any site onground is random in nature with its amplitude anddirection varying randomly with time.
Large earthquakes at great distances can produceweak motions that may not damage structures or evenbe felt by humans. But, sensitive instruments canrecord these. This makes it possible to locate distantearthquakes. However, from engineering viewpoint,strong motions that can possibly damage structuresare of interest. This can happen with earthquakes inthe vicinity or even with large earthquakes atreasonable medium to large distances.
Characteristics of Strong Ground MotionsThe motion of the ground can be described in
terms of displacement, velocity or acceleration. Thevariation of ground acceleration with time recorded ata point on ground during an earthquake is called anaccelerogram. The nature of accelerograms may vary(Figure 4) depending on energy released at source,type of slip at fault rupture, geology along the travelpath from fault rupture to the Earth's surface, and
_Mge2local soil (Figure 1). They carry distinct informationregarding ground shaking; peak amplitude, duration ofstrong shaking, frequency content (e.g., amplitude ofshaking associated with each frequency) and energycontent (i.e., energy carried by ground shaking at eachfrequency) are often used to distinguish them.
Peak amplitude (peak ground acceleration, PGA) isphysically intuitive. For instance, a horizontal PGAvalue of 0.6g (= 0.6 times the acceleration due togravity) suggests that the movement of the ground cancause a maximum horizontal force on a rigid structureequal to 60% of its weight. In a rigid structure, allpoints in it move with the ground by the sameamount, and hence experience the same maximumacceleration of PGA. Horizontal PGA values greaterthan l.Og were recorded during the 1994 NorthridgeEarthquake in USA. Usually, strong ground motionscarry significant energy associated with shaking offrequencies in the range 0.03-30Hz (i.e., cyclespersec).
1985 Mexico Earthquake (SCT IA: N90EI
1940 ImperialValleyEarthquake(ElCenlro; SOOE)
ihod mgxico tan'iqadAe (ol i m; newt;
M—»" * ••"
1971 San Fernando Earthquake(Pacotma Dam. N76W)
20 30 40 50 60Time (sec)
1991 Uttarkashi Earthquake (Ottarkashi. N75E)K..»—-.~. .- , ..
Figure 4::Some typical recorded accelerograms M
Generally, the maximum amplitudes of horizontalmotions in the two orthogonal directions are about thesame. However, the maximum amplitude in thevertical direction is usually less than that in thehorizontal direction. In design codes, the verticaldesign acceleration is taken as VI to 2/3 of thehorizontal design acceleration. In contrast, themaximum horizontal and vertical ground accelerationsin the vicinity of the fault rupture do not seem to havesuch a correlation.
Resource MaterialBolt.B.A., (1999), Earthquakes, Fourth Edition, W. II. Frit-man and
Company, New York, USA
Authored by:CV.RMtlrtyIndian institute of Technology KanpurKanpur, India
Sponsored by:Building Materials and Iechnology PromotionCouncil, New Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/comments maybe sent to: eatips{aiitk.ac.in.Toseeother IITK-BMTPC Earthquake Tips, seewww.nicee.org
May 2002
IITK - bnflPC
Earthquake Tip
LearningEarthquake Designand
Construction
What are Magnitude and Intensity?
TerminologyThe point on the fault where slip starts is the Focus
or Hypocenter, and the point vertically above this onthe surface of the Earth is the Epicenter (Figure 1). Thedepth of focus from the epicenter, called as Focal Depth,is an important parameter in determining thedamaging potential of an earthquake. Most of thedamaging earthquakes have shallow focus with focaldepths less than about 70km. Distance from epicenterto any point of interest is called epicentral distance.
Epicentral Distance
Figure 1: Basic terminology
Place of
Interest
A number of smaller size earthquakes take placebefore and after a big earthquake (i.e., the Main Shock).Those occurring before the big one are calledForeshocks, and the ones after are called Aftershocks.
MagnitudeMagnitude is a quantitative measure of the actual
size of the earthquake. Professor Charles Richternoticed that (a) at the same distance, seismograms(records of earthquake ground vibration) of largerearthquakes have bigger wave amplitude than those ofsmaller earthquakes; ^nd (b) for a given earthquake,seismograms at farther distances have smaller waveamplitude than those at close distances. Theseprompted him to propose the now commonly usedmagnitude scale, the Richter Scale. It is obtained fromthe seismograms and accounts for the dependence ofwaveform amplitude on epicentral distance. This scaleis also called Local Magnitude scale. There are othermagnitude scales, like the Body Wave Magnitude,Surface Wave Magnitude and Wave Energy Magnitude.These numerical magnitude scales have no upper andlower limits; the magnitude of a very small earthquakecan be zero or even negative.
An increase in magnitude (M) by 1.0 implies 10times higher waveform amplitude and about 31 timeshigher energy released. For instance, energy releasedin a M7.7 earthquake is about 31 times that released ina Mb.7 earthquake, and is about 1000 (=31x31) timesthat released in a M5.7 earthquake. Most of the energy
released goes into heat and fracturing the rocks, andonly a small fraction of it (fortunately) goes into theseismic waves that travel to large distances causingshaking of the ground en-route and hence damage tostructures. (Did you know? The energy released by aM6.3 earthquake is equivalent to that released by the1945 Atom Bomb dropped on Hiroshima!!)
Earthquakes are often classified into differentgroups based on their size (Table 1). Annual averagenumber of earthquakes across the Earth in each ofthese groups is also shown in the table; it indicates thaton an average one Great Earthquake occurs each year.Table 1: Global occurrence ofearthquakes
Group Magnitude Annual Average Number
Gnat 8 and higher I
Major 7-7.9 18
Strong 6 -6.9 120
Moderate 5-5.9 800
Light 4-4.9 6,200 (estimated)Minor 3-3.9 49,000 (estimated)
Very Minor <3.0 M2-3: -1,000/dav; Ml-2: -8.000/daySource. http::/neic.usgs.gov/neis/eqIists/eqstats.html
IntensityIntensity is a qualitative measure of the actual
shaking at a location during an earthquake, and isassigned as Roman Capital Numerals. There are manyintensity scales. Two commonly used ones are theModified Mercalli Intensity (MMl) Scale and the MSKScale. Both scales are quite similar and range from I(least perceptive) to XII (most severe). The intensityscales are based on three features of shaking -perception by people and animals, performance ofbuildings, and changes to natural surroundings. Table2 gives the description of Intensity VIII on MSK Scale.
The distribution of intensity at different placesduring an earthquake is shown graphically usingisoseismals, lines joining places with equal seismicintensity (Figure 2).
Figure 2: Isoseismal Map of the 2001 Bhuj (India)Earthquake (MSK Intensity)
Source;
http::/www.nicee.org/nicee/EQReports/Bhuj/isoseismaI.html
IITK-BMTPC Earthquake Tip 3
What are Magnitude and Intensity?Table 2: Description of shaking intensity VIII as per
MSK scale
(a) Fright and panic. Also, persons driving motorcars aredisturbed. Here and there branches of trees break off. Even
heavy furniture moves and partly overturns. Hanginglamps are damaged in part.
(b) Most buildings of Type C suffer damage of Grade 2, andfew of Grade 3. Most buildings of Type Bsuffer damage ofGrade 3, and most buildings of Type A suffer damage ofGrade 4. Occasional breaking of pipe seams occurs.Memorials and monuments move and twist. Tombstones
overturn. Stonewalls collapse.(c) Small landslips occur in hollows and on banked roads on
steep slopes; cracks develop in ground up to widths ofseveral centimeters. Water in lakes becomes turbid. New
reservoirs come into existence. Dry wells refill and existingw'lls become dry. In many cases, changes in flow and levelol water are observed.
Note
TypeA structures- rural constructions; Type B - ordinarymasonry constructions; Type C - Well-built structures
Single, Few - about 5%; Many - about 50%; Most - about 75%Grade 1 Damage - Slight damage; Grade 2 - Moderatedamage; Grade 3 - Heavy damage; Grade 4 - Destruction;Grade5 - Total damage
Basic Difference: Magnitude versus IntensityMagnitude of an earthquake is a measure of its size.
For instance, one can measure the size of anearthquake by the amount of strain energy released bythe fault rupture. This means that the magnitude of theearthquake is a single value for a given earthquake. Onthe other hand, intensity is an indicator of the severityof shaking generated at a given location. Clearly, theseverity of shaking is much higher near the epicenterthan farther away. Thus, during the same earthquakeof a certain magnitude, different locations experiencedifferent levels of intensify.
To elaborate this distinction, consider the analogyof an electric bulb (Figure 3). The illumination at alocation near a 100-Walt bulb is higher than thatfarther away from it. While the bulb releases 100 Wattsof energy, the intensity of light (or illumination,measured in lumens) at a location depends on thewattage of the bulb and its distance from the bulb.Here, the size of the bulb (100-Watt) is like themagnitude of an earthquake, and the illumination at alocation like the intensity of shaking at that location.
Magnitude and Intensity in Seismic DesignOne often asks: Can my building withstand a
magnitude 7.0 earthquake? But, the M7.0 earthquakecauses different shaking intensities at differentlocations, and the damage induced in buildings atthese locations is different. Thus, indeed it is particularlevels of intensity of shaking that buildings andstructures are designed to resist, and not so much themagnitude. The peak ground acceleration (PGA), i.e.,maximum acceleration experienced by the groundduring shaking, is one way of quantifying the severityof the ground shaking. Approximate empiricalcorrelations are available between the MM intensities
and the PGA that may be experienced (e.g., Table 3).For instance, during the 2001 Bhuj earthquake, the area
PW 2enclosed by the isoseismal VIII (Figure 2) may haveexperienced a PGA of about 0.25-0.30g. However, nowstrong ground motion records from seismicinstruments are relied upon to quantify destructiveground shaking. These are critical for cost-effectiveearthquake-resistant design.
Table 3: PGAs during shaking of different intensitiesVII VIII l\
I0.03-0.04 0.06-0.07 0.10-0.15 0.25-0.30 0.50-O.55 >0.60
Source: B.A.Bolt, Earthquakes, W.H.Freeman and Co., New York, 1993
Based on data from past earthquakes, scientistsGutenberg and Richter in 1956 provided anapproximate correlation between the Local MagnitudeMi of an earthquake with the intensity hi sustained in
the epicentral area as: Ml =% '" + '• (P°r using thisequation, the Roman numbers of intensity are replacedwith the corresponding Arabic numerals, e.g., intensityIX with 9.0). There are several different relationsproposed by other scientists.
100 Watt Bulb
Bright(100 lumens)
Near
Normal'
(50 lumens)
Dull
(20 lumens)
Figure 3: Reducing illumination with distancefrom an electric bulb
0
Resource MaterialRichter.C.F., (1958), Elementary Seismology, W. II. Freeman and
Company Inc. San Francisco, USA. (Indian Reprint in 1969 bvEurasia Publishing House Private Limited, New Delhi)
http://neic.usgs.gov/neis/general/handouts/ magnitudejntensity.html
Authored hi:
C.V.R.Murlv
Indian Institute of Technology KanpurKanpur, India
Sponsored I'}/:Building Materials and Technology PromotionCouncil, New Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi It may be reproduced without changing its contentsand with due acknowledgement.
Suggestions/comments may be sent to: eqtips(aiitk.ac.mToseeotherIITK-BMTPC Earthquake Tips,visit www.nicee.org
lime 2002
IITK - bnflScEarthquake Tip
Where are the Seismic Zones in India?
Basic Geography and Tectonic FeaturesIndia lies at the northwestern end of the Indo-
Australian Plate, which encompasses India, Australia, amajor portion of the Indian Ocean and other smallercountries. This plate is colliding against the hugeEurasian Plate (Figure 1) and going under the EurasianPlate; this process of one tectonic plate getting underanother is called subduction. A sea, Tethys, separatedthese plates before they collided. Part of thelithosphere, the Earth's Crust, is covered by oceansand the restby the continents. The former can undergosubduction at great depths when it converges againstanother plate, but the latter is buoyant and so tends toremain close to the surface. When continents converge,large amounts of shortening and thickening takesplace, like at the Himalayas and theTibet/ ^s: ——n
Figure 1: Geographical Layout and\. Tectonic Plate Boundaries at India
Three chief tectonic sub-regions of India are themight)' Himalayas along the north, the plains of theGanges and other rivers, and the peninsula. TheHimalayas consist primarily of sediments accumulatedover long geological time in the Tethys. The Indo-Gangetic basin with deep alluvium is a greatdepression caused by the load of the Himalayas on thecontinent. The peninsular part of the country consistsof ancient rocks deformed in the past Himalayan-likecollisions. Erosion has exposed the roots of the oldmountains and removed most of the topography. Therocks are very hard, but are softened by weatheringnear the surface. Before the Himalayan collision,several tens of millions of years ago, lava flowed
across the central part of peninsular India leavinglayers of basalt rock. Coastal areas like Kachchh showmarine deposits testifying to submergence under thesea millions of years ago.Prominent Past Earthquakes in India
A number of significant earthquakes occurred inand around India over the past century (Figure 2).Some of these occurred in populated and urbanizedareas and hence caused great damage. Many wentunnoticed, as they occurred deep under the Earth'ssurface or in relatively un-inhabited places. Some ofthe damaging and recent earthquakes are listed inTable 1. Most earthquakes occur along the Himalayanplate boundary (these are inter-plate earthquakes), buta number of earthquakes have also occurred in thepeninsular region (theseare intra-plate earthquakes).
Figure 2: Some Past Earthquakes
Four Great earthquakes (M>8) occurred in a spanof 53 years from 1897 to 1950; the January 2001 Bhujearthquake (M7.7) is almost as large. Each of thesecaused disasters, but also allowed us to learn aboutearthquakes and to advance earthquake engineering.For instance, 1819 Cutch Earthquake produced anunprecedented ~3m high uplift of the ground over100km (called Allah Bund). The 1897 Assam Earthquakecaused severe damage up to 500km radial distances;the type of damage sustained led to improvements inthe intensity scale from l-X to I-XII. Extensiveliquefaction of the ground took place over a length of300km (called the Slump Belt) during 1934 Bihar-Nepalearthquake in which many buildings and structureswent afloat.
IITK-BMTPC Earthquake Tip 4
Where are the Seismic Zones in India?
Table 1: Some Past Earthquakes in India
Date Event Time Magnitude . ' ' Deaths 1e Intensity |16 June 1819 Cutch 11:00 83 IX 1.500
12 June 1897 Assam 16:25 8.7 XII 1,500
8 Feb. 1900 Coimbatore 03:11 6.0 VII Nil
4 Apr. 1905 Kangra 06:10 8.0 \ 19,000
15 Jan. 1934 Bihar-Nepal 14:13 8.3 X 11,000
15 Aug. 1950 Assam 19:39 8.6 X 1530
21 Jul. 1956 An].u 21:02 6.1 IX 115
10 Dec. 1967 Koyna 04:30 6.5 VIM 200
23 Mar. 1970 Bharuch 2056 5.2 VII 30
21 Aug. 1988 Bihar-Nepal 04:39 6.6 IX 1.004
20 Oct. 1991 Uttarkashi 02:53 6.4 IX 768
30 Sep.1993 Killari (Latur) 03:53 6.2 V1I1 7,928
22 Mav 1997 Jabalpur 04:22 6.0 VIII 38
29 Mar. 1999 Chamoli 00:35 6.6 VIII 63
26 l.i 2001 Bhuj 08:46 7.7 \ 13,805
The timing of the earthquake during the day andduring the year critically determines the number ofcasualties. Casualties are expected to be high forearthquakes that strike during cold winter nights,when most of the population is indoors.
Seismic Zones of IndiaThe varying geology at different locations in the
country implies that the likelihood of damagingearthquakes taking place at different locations isdifferent. Thus, a seismic zone map is required so thatbuildings and other structures located in differentregions can be designed to withstand different level ofground shaking. The current zone map subdividesIndia into five zones - 1, II, III, IV and V (Figure 3). Themaximum Modified Mercalli (MM) intensity of seismicshaking expected in these zones are V or less, VI, VII,VIII, and IX and higher, respectively. Parts ofHimalayan boundary in the north and northeast, andthe Kachchh area in the west are classified as zone V.
Figure 3: Current Indian Seismic Zone Map(IS:1893-1984)
The seismic zone maps are revised from time totime as more understanding is gained on the geology,the seismotectonics and the seismic activity in thecountry. For instance, the Koyna earthquake of 1967occurred in an area classified in zone I as per map of
J>age21966. The 1970 version (same as Figure 3) of codeupgraded the area around Koyna to zone IV. TheKillari (Latur) earthquake of 1993 occurred in zone I.The new zone map under print (Figure 4) places thisarea in zone III.The new zone map will now have only-four seismic zones - II, III, IV and V. The areas fallingin seismic zone I in the current map are merged withthose of seismic zone II. Also, the seismic zone map inthe peninsular region is being modified. Madras willcome under seismic zone III as against zone IIcurrently.
Figure 4: Revised Indian Seismic Zone Map(under print by BIS)
The national Seismic Zone Map presents a large-scale view of the seismic zones in the country. Localvariations in soil type and geology cannot berepresented at that scale. Therefore, for importantprojects, such as a majordam or a nuclear power plant,the seismic hazard is evaluated specifically for thatsite. Also, for the purposes of urban planning,metropolitan areas are microzoned. Seismicmicrozonation accounts for local variations in geology,local soil profile, etc.
Resource MaterialBMTPC, (1997), Vulnerability Atlas of India, Building Materials and
Technology Promotion Council, Ministry of Urban Development.Government of India, New Delhi.
Dasgupta, S., et al, (2000), Seisnwtectontc Atlas of Indian and itsEnvirons, Geological Survey of India,Calcutta.
IS:1893, (1984), Indian Standard Criteria for Earthquake ResistantDesignof Structures, Bureauof Indian Standards, New Delhi.
Authored by:C.V.K Mmtv
Indian Institute >>l Technology KanpurKanpur, India
Sponsored by:Building Materials and Technology PromotionCouncil, New IVlhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement.
Suggestions/comments may be sent to: eqtipskiiitk.ac.inTo seeother IITK-BMTPC Earthquake Tips, visit www.nicee.org
luly 2002
IITK - mmEarthquake Tip
LearningEarthquake Designand
Construction
What are the Seismic Effects on Structures?
Inertia Forces in Structures
Earthquake causes shaking of the ground. So abuilding resting on it will experience motion at itsbase. From Newton's First Law of Motion, even thoughthe base of the building moves with the ground, theroof has a tendency to stay in its original position. Butsince the walls and columns are connected to it, theydrag the roof along with them. Tins is much like thesituation that you are faced with when the bus you arestanding in suddenly starts; your feet move with the bus,but your upper body tends to stay back making you fallbackwards!! This tendency to continue to remain in theprevious position is known as inertia. In the building,since the walls or columns are flexible, the motion of
the roof is different from that of the ground (Figure 1).
Figure 1: Effect of Inertia in a building whenshaken at its base
Consider a building whose roof is supported oncolumns (Figure 2). Coming back to the analogy ofyourself on the bus: when the bus suddenly starts, you arethrown backwards as if someone has applied a force on theupper body. Similarly, when the ground moves, eventhe building is thrown backwards, and the roofexperiences a force, called inertia force. If the roof has amass M and experiences an acceleration a, then fromNewton's Second Law of Motion, the inertia force Fi ismass M times acceleration a, and its direction is
opposite to that of the acceleration. Clearly, more massmeans higher inertia force. Therefore, lighter buildingssustain the earthquake shaking better.
Effect of Deformations in StructuresThe inertia force experienced by the roof is
transferred to the ground via the columns, causingforces in columns. These forces generated in thecolumns can also be understood in another way.During earthquake shaking, the columns undergorelative movement between their ends. In Figure 2,this movement is shown as quantity U between theroof and the ground. But, given a free option, columns
would like to come back to the straight verticalposition, i.e., columns resist deformations. In thestraight vertical position, the columns carry nohorizontal earthquake force through them. But, whenforced to bend, they develop internal forces. The largeris the relative horizontal displacement u between thetop and bottom of the column, the larger this internalforce in columns. Also, the stiffer the columns are (i.e.,bigger is the column size), larger is this force. For thisreason, these internal forces in the columns are called
stiffnessforces. In fact, the stiffness force in a column isthe column stiffness times the relative displacementbetween its ends.
Inertia Force
Roof
Acceleration
Figure 2: Inertia force and relative motion withina building
Horizontal and Vertical ShakingEarthquake causes shaking of the ground in all
three directions - along the two horizontal directions(X and Y, say), and the vertical direction (Z, say) (Figure3). Also, during the earthquake, the ground shakesrandomly back andforth (- and +) along each of these X,Y and Z directions. All structures are primarilydesigned to carry the gravity loads, i.e., they aredesigned for a force equal to the mass M (this includesmass due to own weight and imposed loads) limes theacceleration due to gravity g acting in the verticaldownward direction (-Z). The downward force Mg iscalled the gravity load. The vertical acceleration duringground shaking either adds to or subtracts from theacceleration due to gravity. Since factors of safety areused in the design of structures to resist the gravityloads, usually most structures tend to be adequateagainst vertical shaking.
IITK-BMTPC Earthquake Tip 6
How Architectural Features Affect Buildings During Earthquakes? jmgelthat storey. Many buildings with an open groundstorey intended for parking collapsed or were severelydamaged in Gujarat during the 2001 Bhuj earthquake.
Buildings on slopy ground have unequal heightcolumns along the slope, which causes ill effects liketwisting and damage in shorter columns (Figure 3c).Buildings with columns that hang or float on beams atan intermediate storey and do not go all the way to thefoundation, have discontinuities in the load transfer
path (Figure 3d). Some buildings have reinforcedconcrete walls to carry the earthquake loads to thefoundation. Buildings, in which these walls do not goall the way to the ground but stop at an upper level,are liable to get severely damaged during earthquakes.
•DDDDDDDDDDQDaDDDDDOdDOOODaDDDDDDDDDDDDD
3uM8Bft
(a) Setbacks
DDDDDDDDDDDD
uiniTU
^m
—
UnusuallyTall
• Storey
(b) Weak or Flexible Storey
^itfi
ELI(c) Slopy Ground (d) Hanging or Floating Columns
win
Reinforced
Concrete Wall
Discontinued in
Ground Storey
(e) Discontinuing Structural Members
Figure 3: Sudden deviations in load transfer pathalong the height lead to poor performance ofbuildings.
Adjacency of Buildings: When two buildings aretoo close to each other, they may pound on each otherduring strong shaking. With increase in buildingheight, this collision can be a greater problem. Whenbuilding heights do not match (Figure 4), the roof ofthe shorter building may pound at the mid-height ofthe column of the taller one; this can be verydangerous.
((
i1n
Yi
I
inn
<ul.!
Figure 4: Pounding can occur between adjoiningbuildings due to horizontal vibrations of thetwo buildings.
Building Design and Codes...Looking ahead, of course, one will continue to
make buildings interesting rather than monotonous.However, this need not be done at the cost of poorbehaviour and earthquake safety of buildings.Architectural features that are detrimental to
earthquake response of buildings should be avoided. Ifnot, they must be minimised. When irregular featuresare included in buildings, a considerably higher levelof engineering effort is required in the structuraldesign and yet the building may not be as good as onewith simple architectural features.
Decisions made at the planning stage on buildingconfiguration are more important, or are known tohave made greater difference, than accuratedetermination of code specified design forces.
Resource MaterialArnoId.C, and Reitherman.K., (1982), Building Configuration and
Seismic Design, John Wiley. USA.Lagorio.HJ, (1990), EARTHQUAKES An Architect's Guide to Non-
Structural Scisinit Hazard, |ohn Wiley & Sons, Inc., USA.
Next Upcoming TipHow Buildings Twist During Earthquakes?
\J
Authored by:C.V.R.Murtv
Indian Institute ol technology KanpurKanpur, India
Sponsored by:Building Materials and Technology PromotionCouncil. New Delhi, India
This release is a property of uT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement.
Suggestions/comments may be sent to: eqtipstuiitk.ac.inTo seeprevious IITK-BMTPC Earthquake Tips, visitwww.nicee.orp
September 2002
IITK - timlPCEarthquake Tip
How Buildings Twist During Earthquakes?
Why a Building TwistsIn your childhood, you must have sat on a rope
swing - a wooden cradle tied with coir ropes to thesturdy branch of an old tree. The more modernversions of these swings can be seen today in thechildren's parks in urban areas; they have a plasticcradle tied with steel chains to a steel framework.
Consider a rope swing that is tied identically with twoequal ropes. It swings equally, when you sit in themiddle of the cradle. Buildings too are like these ropeswings; just that they are inverted swings (Figure 1).The vertical walls and columns are like the ropes, andthe floor is like the cradle. Buildings vibrate back andforth during earthquakes. Buildings with more thanone storey are like rope swings with more than onecradle.
•'1A
(a) Single-storey building (b) Three-storey buildingFigure 1: Rope swings and buildings, both swing
back-and-forth when shaken horizontally. Theformer are hung from the top, while the latterare raised from the ground.
Thus, if you see from sky, a building with identicalvertical members and that are uniformly placed in thetwo horizontal directions, when shaken at its base in acertain direction, swings back and forth such that allpoints on the floor move horizontally by the sameamount in the direction in which it is shaken (Figure 2).
Uniform Movement
of Floor
0• G
•
•
a
•
a
fm••••••»••••••••!••••••••¥•••••••••Vt•••••••
J. JJ. _•.
7VerticalJIdentical Vertical^Members 4
EarthquakeGround
Movement
Figure 2: Identical vertical members placeduniformly in plan of building cause all pointson the floor to move by same amount.
Again, let us go back to the rope swings on thetree: if you sit at one end of the cradle, it twists (i.e.,moves more on the side you are sitting). This alsohappens sometimes when more of your friends bunchtogether and sit on one side of the swing. Likewise, ifthe mass on the floor of a building is more on one side(for instance, one side of a building may have a storageor a library), then that side of the building moves moreunder ground movement (Figure 3). This buildingmoves such that its floors displace horizontally as wellas rotate.
Light Sideof Building
Twist
• • • • •• •nam • • D
n n a a a • DD:|• • • • • a a • 1
EarthquakeGround Shaking*
Heavy Sideof Building
Figure 3: Even if vertical members are placeduniformly in plan of building, more mass onone side causes the floors to twist.
IITK-BMTPC Earthquake lip 7low Buildings Twist During Earthquakes?
Once more, let us consider the rope swing on thetree. This Hme let the two ropes with which the cradlei» tied to the branch of the tree be different in length.Such • swing also hoists even if you sit In the middle(Figure 4a), Similarly, in buildings with unequalvertical members (i.e., columns and/or walls) also thefloors twist about a vertical axis (Figure 4b) anddisplace horizontally. Likewise, buildings, which havewalls only on two sides (or one side) and thin columnsalong the other, twist when shaken at the ground level(Figure 4c).
o^ro
(aj Swing with unequalropea
••vomi *m item*
f«rthqu.akeQrsundMovement
(D iwiteing on stepyground
*\
MSblillgftlltfllMMfeMlMttbmalfMfllfriM^&Wr% * luiMngt have unequal vertical
members; theyeau%e the building t© twistabout a vertical a*i%-.
Building*, that are iFfeaular shapes, inplan fend tatwi*t wvdef earthquake shaking-. ftw example,, in apropped ovahangtng building tRgwe % theweftanpng portion swing* nn the relatively aten&rcolumn* under it The Aw** twtet and'di&ptaehownntally-.
jmlZ
EarthquakeGround
Shaking
Figure 5: One-side open ground storey buildingtwists during earthquake shaking.
What Twist docs to Building MembersTwist in buildings, called torsion by engineers,
makes different portions at the same floor level tomove horizontally by different amounts. This inducesmore damage in the columns and walls on the sidethat moves more (Figure 6). Many buildings havebeenseverely affected by this excessive torsional behaviourduring past earthquakes, It is best to minimize (if notcompletely avoid) this twist by ensuring that buildingshave symmetry in plan (i.e., uniformly distributedmass and uniformly placed vertical members). If thistwist cannot be avoided, special calculations need tobe done to account for this additional shear forces inthe design of buildings; the Indian seismic code (ISlrW,\ 2002) has provisions for such calculations. But,for sure, buildings with twist will perform poorlyduringstrong earthquake shaking.
3iarthquak©
BtWMMovement
Tftese eoiumns are more vulnerableFigure 8; Vertical member* of buildings that move
more horizontally sustain more damage.
••••'..••
..•..• .»•
.•••• ••
.•• ,.••*
FZu.-ti u u tu
f H a • • a
D 0 aA-*"!,» 13 a akiS
Resource MaterielAmnkte* and RetthwnwtvR., (1«*IX HhMjhs Ci«M«sH'«»h«« ml
*«*»» iVttjpt. kvw Wiley, USA1-*K«kyHJ, Am MRTHQUAki-S -At« AMwfeftt Gw* to Nw-
nmetwil mam ♦*«<»<*,kwww*y &Sbm,tw-,um,Nc*t gpeemwg Tip
WtatMhe***smH tV»^» rt«k«»ipit\ Kx »MiKlH\a»?
• ^
0e#» * «**# fee raprcduatd mfthart e*wws}w» <&> ««**♦*
feSKJMWfelK4RK4Mf¥@fiMllSWteT|]»,¥&* vvvvyy i^vXiUSS
IITK - bmlpcEarthquake Tip
What is the Seismic Design Philosophy for Buildings?
The Earthquake ProblemSeverity of ground shaking at a given location
during an earthquake can be minor, moderate andstrong. Relatively speaking, minor shaking occursfrequently, moderate shaking occasionally and strongshaking rarely. For instance, on average annuallyabout 800 earthquakes of magnitude 5.0-5.9 occur inthe world while the number is only about 18 formagnitude range 7.0-7.9 (see Table 1 of IITK-BMTPCEarthquake Tip 03 at wiow.nicee.org). So, should wedesign and construct a building to resist that rareearthquake shaking that may come only once in 500years or even once in 2000 years at the chosen projectsite, even though the life of the building itself may beonly 50or 100 years? Since it costs money to provideadditional earthquake safety in buildings, a conflictarises: Should we do away with the design ofbuildings forearthquake effects? Or should we design the buildings to be"earthquake proof wherein there is no damage during thestrong but rare earthquake shaking? Clearly, the formerapproach can lead to a major disaster, and the secondapproach is too expensive. Hence, the designphilosophy should lie somewhere in between thesetwo extremes.
Earthquake-Resistant BuildingsThe engineers do not attempt to make earthquake-
proof buildings that will not get damaged even duringthe rare but strong earthquake; such buildings will betoo robust and also too expensive. Instead, theengineering intention is to make buildings earthquake-resistant; such buildings resist the effects of groundshaking, although they may get damaged severely butwould not collapse during the strong earthquake.Thus, safety of people and contents is assured inearthquake-resistant buildings, and thereby a disasteris avoided. This is a major objective of seismic designcodes throughout the world.
Earthquake Design PhilosophyThe earthquake design philosophy may be
summarized as follows (Figure 2):(a) Under minor but frequent shaking, the main
members of the building that carry vertical andhorizontal forces should not be damaged; howeverbuilding parts that do not carry load may sustainrepairable damage.
(b) Under moderate but occasional shaking, the mainmembers may sustain repairable damage, while theother parts of the building may be damaged suchthat they may even have to be replaced after theearthquake; and
(c) Under strong but rare shaking, the main members
may sustain severe (even irreparable) damage, butthe building should not collapse.
Figure 2: Performance objectives under differentintensities of earthquake shaking - seekinglow repairable damage under minorshaking andcollapse-prevention under strong shaking.
Thus, after minor shaking, the building will befully operational within a short time and the repaircosts will be small. And, after moderate shaking, thebuilding will be operational once the repair andstrengthening of the damaged main members iscompleted. But, after a strong earthquake, the buildingmay become dysfunctional for further use, but willstand so that people can be evacuated and propertyrecovered.
The consequences of damage have to be kept inview in the design philosophy. For example, importantbuildings, like hospitals and fire stations, play a criticalrole in post-earthquake activities and must remainfunctional immediately after the earthquake. Thesestructures must sustain very little damage and shouldbe designed for a higher level of earthquakeprotection. Collapse of dams during earthquakes cancause flooding in the downstream reaches, which itselfcan be a secondary disaster. Therefore, dams (andsimilarly, nuclear power plants) should be designedfor still higher level of earthquake motion.
Damage in Buildings: UnavoidableDesign of buildings to resist earthquakes involves
controlling the damage to acceptable levels at a reasonablecost. Contrary to the common thinking that any crackin the building after an earthquake means the buildingis unsafe for habitation, engineers designingearthquake-resistant buildings recognize that some
IITK-BMTPC Earthquake Tip 8
What is the Seismic Design Philosophy for Buildings?damage is unavoidable. Different types of damage(mainly visualized though cracks; especially so inconcrete and masonry buildings) occur in buildingsduring earthquakes. Some of these cracks areacceptable (in terms of both their size and location),while others are not. For instance, in a reinforced
concrete frame building with masonry filler wallsbetween columns, the cracks between vertical columns
and masonry filler walls are acceptable, but diagonalcracks running through the columns are not (Figure 3).In general, qualified technical professionals areknowledgeable of the causes and severity of damagein earthquake-resistant buildings.
mFigure 3: Diagonal cracks in columns jeopardize
vertical load carrying capacity of buildings -unacceptable damage.
E.irthquake-resistant design is therefore concernedabout ensuring that the damages in buildings duringearthquakes are of the acceptable variety, and also thatthey occur at the right places and in right amounts.This approach of earthquake-resistant design is muchlike the use of electrical fuses in houses: to protect theentire electrical wiring and appliances in the house, yousacrifice some small parts of the electrical circuit, calledfuses; these fuses are easilyreplaced after the electrical oi'er-current. Likewise, to save the building from collapsing,you need to allow some pre-determined parts toundergo the acceptable type and level of damage.
Acceptable Damage: DuctilitySo, the task now is to identify acceptable forms of
damage and desirable building behaviour duringearthquakes. To do this, let us first understand howdifferent materials behave. Consider white chalk used
to write on blackboards and steel pins with solid headsused to hold sheets of paper together. Yes... a chalkbreaks easily'.'. On the contrary, a steel pin allozvs it to bebent back-and-forth. Engineers define the property thatallows steel pins to bend back-and-forth by largeamounts, as ductility; chalk is a brittle material.
Earthquake-resistant buildings, particularly theirmain elements, need to be built with ductility in them.Such buildings have the ability to sway back-and-forthduring an earthquake, and to withstand earthquakeeffects with some damage, but without collapse(Figure 4). Ductility is one of the most important
_page2factors affecting the building performance. Thus,earthquake-resistant design strives to predeterminethe locations where damage takes place and then toprovide good detailing at these locations to ensureductile behaviour of the building.
ao
u.
aJCra
3
IIuj-3
11o oNEo
I
1 'o
Ductile
Performance]
S
BrittleCollapse
I 9
Horizontal Movement of Roof of Buildingrelative to its base
(a) Building performances during earthquakes:two extremes - the ductile and the brittle.
X&" -
(b) Brittle failure of a reinforced concretecolumn
Figure 4: Ductile and brittle structures - seismicdesign attempts to avoid structures of the latterkind.
Resource MaterialNaeim.F., Ed., (2001), VieSeismic Design Handbook, Kluvver Academic
Publishers, Boston, USA.
Ambrose.J., and Vergun.D., (1999), DesignforEarthquakes, JohnWiley& Sons, Inc., New York.
Next Upcoming TipHow to makebuildings ductile for good seismic performance?
Authored In/:
CV.K.Murtv
Indian Instituteof technology KanpurKanpur, India
Sponsored by:Building Materials and Technology PromotionCouncil, \eu Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi It may be reproduced without changing its contentsand with due acknowledgement.
Suggestions/comments may be sent to: eqtips(uiitk.ac.inTo see previous IITK-BMTPC Earthquake Tips, visit www.nicee.org
November 2002
IITK -BmlPCEarthquake Tip
LearningEarthquake Designand
Construction
How to Make Buildings Ductile for Good Seismic Performance?
Construction Materials
In India, most non-urban buildings are made inmasonry. In the plains, masonry is generally made ofburnt clav bricks and cement mortar. However, in hillyareas, stone masonry with mud mortar is moreprevalent; but, in recent times, it is being replaced withcement mortar. Masonry can carry loads that causecompression (i.e., pressing together), but can hardly takeload that causes tension (i.e., pulling apart) (Figure 1).
Compression Tension
Strong
Figure 1: Masonry is strong in compression butweak in tension.
Concrete is another material that has been
popularly used in building construction particularlyover the last four decades. Cement concrete is made ofcrushed stone pieces (called aggregate), sand, cementand water mixed in appropriate proportions. Concreteis much stronger than masonry under compressiveloads, but again its behaviour in tension is poor. Theproperties of concrete critically depend on the amountof water used in making concrete; too much and toolittle water, both can cause havoc. In general, bothmasonry andconcrete are brittle, and fail suddenly.
Steel is used in masonry and concrete buildings asreinforcement bars of diameter ranging from 6mm to40mm. Reinforcing steel can carry both tensile andcompressive loads. Moreover, steel is a ductile material.This important property of ductility enables steel barsto undergolargeelongation before breaking.
Concrete is used in buildings along with steelreinforcement bars. This composite material is calledreinforced cement concrete or simply reinforced concrete(RC). The amount and location of steel in a membershould be such that the failure of the member is bysteel reaching its strength in tension before concretereaches its strength in compression. This type offailure is ductile failure, and hence is preferred over afailure where concrete fails first in compression.Therefore, contrary to common thinking, providingtoo much steel in RCbuildings can be harmful even!!
Capacity Design ConceptLet us take two bars of same length and cross-
sectional area - one made of a ductile material and
another of a brittle material. Now, pull these two barsuntil they break!! You will notice that the ductile barelongates by a large amount before it breaks, while thebrittle bar breaks suddenly on reaching its maximumstrength at a relatively small elongation (Figure 2).Amongst the materials used in building construction,steel is ductile, while masonry and concrete are brittle.
Elongation of Bar
Figure 2: Tension Test on Materials - ductileversus brittle materials.
IITK-BMTPC Earthquake Tip 9
How to Make Buildings Ductile for Good Seismic Performance? '"'«<•-
Now, let us make a chain with links made of brittle
and ductile materials (Figure 3). Each of these links willfail just like the bars shown in Figure 2. Now, hold thelast link at either end of the chain and apply a force F.Since the same force F is being transferred through allthe links, the force in each link is the same, i.e., F. As
more and more force is applied, eventually the chainwill break when the weakest link in it breaks. If the
ductile link is the weak one ^.e., its capacity to take loadis less), then the chain will show large final elongation.Instead, if the brittle link is the weak one, then the
chain will fail suddenly and show small finalelongation. Therefore, if we want to have such a ductilechain, we have to make the ductile link to be the
weakest link.
Original Chain
Ductile Link
Loaded Chain
Ductile Link
stretches byyielding beforebreaking
Figure 3: Ductile chain design.
Brittle Links
Brittle Linksdo not yield
Earthquake-Resistant Design of BuildingsBuildings should be designed like the ductile
chain. For example, consider the common urbanresidential apartment construction - the multi-storeybuilding made of reinforced concrete. It consists ofhorizontal and vertical members, namely beams andcolumns. The seismic inertia forces generated at itsfloor levels are transferred through the various beamsand columns to the ground. The correct buildingcomponents need to be made ductile. The failure of acolumn can affect the stability of the whole building,but the failure of a beam causes localized effect.
Therefore, it is better to make beams to be the ductile
weak links than columns. This method of designing RCbuildings is called the strong-column weak-beam designmethod (Figure4).
By using the routine design codes (meant fordesign against non-earthquake effects), designers maynot be able to achieve a ductile structure. Specialdesign provisions are required to help designersimprove the ductility of the structure. Sich provisionsare usually put together in the form of a special seismicdesign code, e.g., IS:13920-1993 for RC structures.These codes also ensure that adequate ductility isprovided in the members wheredamage isexpected.
uWeak Beam
t
Strong-ColumnWeak-Beam
StrongColumn
:=>
/
Weak Column
±
T
Weak-Column
Strong-Beam
Design
StrongBeam
Figure 4: Reinforced Concrete Building Design:the beams must be the weakest links and not
the columns - this can be achieved byappropriately sizing the members and providingcorrect amount of steel reinforcement in them.
Quality Control in ConstructionThe capacity design concept in earthquake-
resistant design of buildings will fail if the strengths ofthe brittle links fall below their minimum assured
values. The strength of brittle construction materials,like masonry and concrete, is highly sensitive to thequality of construction materials, workmanship,supervision, and construction methods. Similarly,special care is needed in construction to ensure thatthe elements meant to be ductile are indeed providedwith features that give adequate ductility. Thus, strictadherence to prescribed standards of constructionmaterials and construction processes is essential inassuring an earthquake-resistant building. Regulartesting of construction materials at qualifiedlaboratories (at site or away), periodic training ofworkmen at professional training houses, and on-siteevaluation of the technical work are elements of goodquality control.
Resource MaterialPaulay.T., and Priestley.M.J.N., (1992), Setose Design of Reinforced
Concrete Buildings andMasonry, John Wiley, USA.Mazzolani,F.M„ and Piluso.V., (1996), Vnvry and Design of Seismic-
Resistant Steel Frames, E&FN Spon, UK
Next Upcoming TipHow flexibility of buildings affects theirearthquake response?
(i Authored hi.
C.V.R.MurtyIndian Instituted technology KanpurKanpur, India
Sponsored by.Building Materialsand (echnaiog) PromotionCouncil, New Delhi. India
This release is a property of ITT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement.
Suggestions/comments may be sent to:eqtips(aiitk.aainTo see previous IITK-BMTPC Eartlitruake Tips, lisit www.niav.nrs
December 2(102
IITK - bnflpcEarthquake Tip
LearningEarthquake Designand
Construction
How Flexibility of Buildings Affects their Earthquake Response?
Oscillations of Flexible BuildingsWhen the ground shakes, the base of a building
moves with the ground, and the building swings back-and-forth. If the building were rigid, then every pointin it would move by the same amount as the ground.But, most buildings are flexible, and different partsmove back-and-forth by different amounts.
Take a fat coir rope and tie one end of it to the roofof a building and its other end to a motorized vehicle(say a tractor). Next, start the tractor and pull thebuilding; it will move in the direction of pull (Figurela). For the same amount of pull force, the movementis larger for a more flexible building. Now, cut therope! The building will oscillate back-and-forthhorizontally and after some time come back to theoriginal position (Figure lb); these oscillations areperiodic. The time taken (in seconds) for each completecycle of oscillation (i.e., one complete back-and-forthmotion) is the same and is called Fundamental NaturalPeriod T of the building. Value of T depends on thebuilding flexibility and mass; more the flexibility', thelonger is the T, and more the mass, the longer is the T.In general, taller buildings are more flexible and havelarger mass, and therefore have a longer T. On thecontrary, low- to medium-rise buildings generallyhave shorter T (less than 0.4 sec).
(a) Building pulled with a rope tied at its roof
Root
Displacement
Inverted Pendulum Model
(b) Oscillation of building on cutting the rope
Figure 1: Free vibration response of a building:the back-and-forth motion is periodic.
Fundamental natural period T is an inherentproperty of a building. Any alterations made to thebuilding will change its T. Fundamental naturalperiods T of normal single storey to 20 storeybuildings are usually in the range 0.05-2.00 sec. Someexamples of natural periods of different structures areshown in Figure 2.
ma.••"-• *l itii •": <:<:<:<:<:
Suspension Bridge: 6 sec
Aoaplfxl Iron Newmaik (1970). ' . "'(?i;r <i."•'• i IptSafcajiAnalysis and Design ot Hgh Rise SBuctures, Chapter 16. InWiegel, (1970), Earthquake Engmeeiing, Prentice Hall. USA.
Figure 2: Fundamental natural periods ofstructures differ over a large range. Thenatural period values are only indicative:depending on actual properties of the structure,natural period may vary considerably.
Single StoreyBuilding:0.05 sec
Reinforced
Concrete
Chimney:2 sec
't*"i"%"'.
15 Storey Building:1 sec
Elevated Water Tank: 4 sec
LargeConcrete Gravity Dam:
0.8 sec
TK-BMTPC Earthquake Tip 10
How Flexibility of Buildings Affects their Earthquake Response? M%e2
Importance of FlexibilityThe ground shaking during an earthquake
contains a mixture of many sinusoidal waves ofdifferent frequencies, ranging from short to longperiods (Figure 3). The time taken by the wave tocomplete one cycle of motion is called period of theearthquake wave In general, earthquake shaking of theground has waves whose periods vary in the range0.03-33sec. Even within this range, some earthquakewaves are stronger than the others. Intensity ofearthquake waves at a particular building locationdepends on a number of factors, including themagnitude of the earthquake, the epicentral distance, andthe type of ground that the earthquake waves travelledthrough before reaching the location of interest.
Short
Period C
Wave
LongPeriod 0Wave
Amplitude
Time
Time
Figure 3: Strong Earthquake Ground Motion istransmitted by waves of different periods.
.
In a typical city, there are buildings of manydifferent sizes and shapes. One way of categorizingthem is by their fundamental nahiral period T. Theground motion under these buildings varies across thecitv (Figure 4a). If the ground is shaken back-and-forthby earthquake waves that have short periods, thenshort period buildings will have large response.Similarly, if the earthquake ground motion has longperiod waves, then long period buildings will havelarger response. Thus, depending on the value of T ofthe buildings and on the characteristics of earthquakeground motion (i.e., the periods and amplitude of theearthquake waves), some buildings will be shakenmore than the others.
During the 1967 Caracas earthquake in SouthAmerica, the response of buildings was found todepend on the thickness of soil under the buildings.Figure 4b shows that for buildings 3-5 storeys tall, thedamage intensity was higher in areas with underlyingsoil cover of around 40-60m thick, but was minimal inareas with larger thickness of soil cover. On the otherhand, the damage intensity was just the reverse in thecase of 10-14 storey buildings; the damage intensitywas more when the soil cover was in the range 150-300m, and small for lower thickness of soil cover.
Here, the soil layer under the building plays the role ofa filter, allowing some ground waves to pass throughand filtering the rest.
fcj.y. Earthquake Shaking '#/$!%
(a) Buildings in a city lie on different soils
250 300Depth of Soil (m)
(b) Intensity of damage depends on thickness ofunderlying soil layer 1967 Caracas Earthquake
Figure 4: Different Buildings Respond Differentlyto Same Ground Vibration.
Flexible buildings undergo larger relativehorizontal displacements, which may result in damageto various nonstructural building components and thecontents. For example, some items in buildings, likeglass windows, cannot take large lateral movements,and are therefore damaged severely or crushed.Unsecured shelves might topple, especially at upperstories of multi-storey buildings. These damages maynot affect safety of buildings, but may cause economiclosses, injuries and panic among its residents.
Related IITK - ffiuTBC TipIITK-BMTPC Earthquake Tip 2: How the Ground Shakes?IITK-BMTPC Earthquake Tip 5: What are the Seismic Effects on
Structure*?
Resource Material
Wiegel,R., (1970), Earthquake Engineering, Prentice Hall Inc., USA.Chopra.A.K... (1980), Dynamics of Structures - A Primer. Earthquake
Engineering Research Institute, USA.
Next Upcoming TipWhat are the Indian Seismic Codes?
Horedby.CV.R.MurrjIndian Institute of Technology KanpurKanpur. India
tsored by.Building Materials and technology PromotionCouncil, New IVIhi. India
This release is a property of WT Kanpur and BMTPC NeuDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eqtjps'yiitk ar.in. Visit tvww.nicee.org orwww.bmtpc.orptosetprevious IITK-BMTPC Earthquake Tips.
January 2003
IITK - hmlpcEarthquake Tip
LearningEarthquake Designand
Construction
What are the Indian Seismic Codes?
Importance of Seismic Design CodesGround vibrations during earthquakes cause
forces and deformations in structures. Structures needto be designed to withstand such forces anddeformations. Seismic codes help to improve thebehaviour of structures so that they may withstand theearthquake effects without significant loss of life andproperty. Countries around the world haveprocedures outlined in seismic codes to help designengineers in the planning, designing, detailing andconstructing of structures. An earthquake-resistantbuilding has four virtues in it, namely:(a) Gtmi Structural Configuration: Its size, shape and
structural system carrying loads are such that theyensure a direct and smooth flow of inertia forces tothe ground.
(b) Lateral Strength: The maximum lateral (horizontal)force that it can resist is such that the damageinduced in it does not result incollapse.
(c) Adequate Stiffness: Its lateral load resisting system issuch that the earthquake-induced deformations init do not damage its contents under low-to-moderate shaking.
(d)Gtxid Ductility: Its capacity to undergo largedeformations under severe earthquake shakingeven after yielding, is improved by favourabledesign and detailing strategies.
Seismiccodes cover all these aspects.
Indian Seismic CodesSeismic codes are unique to a particular region or
country. They take into account the local seismology,accepted level of seismic risk, building typologies, andmaterials and methods used in construction. Further,they are indicative of the level of progress a countryhas made in the field ofearthquakeengineering.
The first formal seismic code in India, namely IS1893, was published in 1962. Today, the Bureau ofIndian Standards (BIS) has the followingseismiccodes:IS 1893 (Part I), 2002, Indian Standard Criteria for
Earthquake Resistant Design of Structures (5,h Revision)IS 4326, 1993, Indian Standard Code of Practice for
Earthquake Resistant Design and Construction ofBuildings (2nd Revision)
IS 13827, 1993, Indian Standard Guidelines for ImprovingEarthquake Resistance of Earthen Buildings
IS 13828, 1993, Indian Standard Guidelines for ImprovingEarthquake Resistance of Low Strength MasonryBuildings
IS 13920, 1993, Indian Standard Code of Practice forDuctile Detailing of Reinforced Concrete StructuresSubjected to Seismic Forces
IS13935, 1993, Indian Standard Guidelines for Repair andSeismic Strengthening ofBuildings
The regulations in these standards do not ensurethat structures suffer no damage during earthquake ofall magnitudes. But, to the extent possible, they ensurethat structures are able to respond to earthquakeshakings of moderate intensities without structuraldamage and oi heavy intensities without total collapse.
IS 1893
IS 1893 is the main code that provides the seismic-zone map (Figure 1) and specifies seismic design force.This force depends on the mass and seismic coefficientof the structure; the latter in turn depends onproperties like seismic zone in which structure lies,importance of the structure, its stiffness, the soil onwhich it rests, and its ductility. For example, abuilding in Bhuj will have 2.25 times the seismicdesign force of an identical building in Bombay.Similarly, the seismic coefficient for a single-storeybuilding may have 15 times that of a 15-storeybuilding.
Figure 1: Seismic Zone Map of India showingfour seismic zones - over 60% of India's landunder seismic zones III. IV and V.
IITK-BMTPC Earthquake Tip 11
What are the Indian Seismic Codes?
The revised 2002 edition, Part 1 of IS1893, containsprovisions that are general in nature and thoseapplicable for buildings. The other four parts of IS1S93 will cover: Liquid-Retaining Tanks, both elevatedand ground supported (Part 2); Bridges and RetainingWalls (Part 3); Industrial Structures including Stack-Like Structures (Part 4); and Dams and Embankments(Part 5). These four documents are under preparation.In contrast, the 1984 edition of IS1893 had provisionsfor all the above structures in a single document.Provisions for Bridges
Seismic design of bridges in India is covered inthree codes, namely IS 1893 (1984) from the BIS, IRC 6(2(XK>) from the Indian Roads Congress, and BridgeRules (1964) from the Ministry of Railways. Allhighway bridges are required to comply with IRC 6,and all railway bridges with Bridge Rules. These threecodes are conceptually the same, even though thereare some differences in their implementation. After the2001 Bhuj earthquake, in 2002, the IRC releasedinterim provisions that make significantimprovements to the IRC6(2000) seismic provisions.
IS 4326, 1993This code covers general principles for earthquake
H istant buildings. Selection of materials and specialfeatures of design and construction are dealt with forthe following types of buildings: timber constructions,masonry constructions using rectangular masonryunits, and buildings with prefabricated reinforcedconcrete roofing/flooring elements.
IS 13827. 1993 and IS 13828, 1993Guidelines in IS 13827 deal with empirical design
and construction aspects for improving earthquake-resistance of earthen houses, and those in IS 13828 withgeneral principles of design and special constructionfeatures for improving earthquake resistance ofbuildings of low-strength masonry. This masonryintludes burnt clay brick or stone masonry in weakmortars, like clay-mud. These standards are applicablein seismic zones III, IV and V. Constructions based on
them are termed non-engineered, and are not totallyfree from collapse under seismic shaking intensitiesVIII (MMI) and higher. Inclusion of featuresmentioned in these guidelines may only enhance theseismicresistanceand reduce chancesof collapse.
IS 13920, 1993In India, reinforced concrete structures are
designed and detailed as per the Indian Code IS 456(2002). However, structures located in high seismicregions require ductile design and detailing. Provisionsfor the ductile detailing of monolithic reinforcedconcrete frame and shear wall structures are specifiedin IS 13920 (1993). After the 2001 Bhuj earthquake, thiscode has been made mandatory for all structures inzones III, IV and V. Similar provisions for seismicdesign and ductile detailing of steel structures are notyet available in the Indian codes.
W J~IS 13935, 1993
These guidelines cover general principles ofseismic strengthening, selection of materials, andtechniques for repair/seismic strengthening ofmasonry and wooden buildings. The code provides abrief coverage for individual reinforced concrete membersin such buildings, but does not cover reinforced concreteframe or shear wall buildings as a whole. Someguidelines are also laid down for non-structural andarchitectural components of buildings.
In Closure-Countries with a history of earthquakes have well
developed earthquake codes. Thus, countries likeJapan, New Zealand and the United States of America,have detailed seismic code provisions. Development ofbuilding codes in India started rather early. Today,India has a fairly good range of seismic codes coveringa variety of structures, ranging from mud or low-strength masonry houses to modern buildings.However, the key to ensuring earthquake safety lies inhaving a robust mechanism that enforces andimplements these design code provisions in actualconstructions.
Related IITK-uTJiTPC TipTip 4: Where are the seismic zones in India?Tip8:What is theseismicdesign philosophy of buildings?Tip 9:How to make buildings ductilefor goodseismicperformance ?Tip 10:Howflexibility of buildingsaffects theirearthquake
response?
Resource MaterialBMTPC, (2000), Guidelines for Improving Earthquake ResistanceofHousing,
Building Materials and Technology Promotion Council, NewDelhi.
Bridge Rules. (1964), Rules Specifying the Ladsfor the Design ofSuperstructure and Substructure of Bridges and for Assessment of theStrength of Existing Bridges. Government of India. Ministry ofRailways(Railway Board).
IRC 6, (2000), Standard Specifications and Code of Practice for RoadBridges - Section II: Loads and Stresses, Indian Roads Congress, NewDelhi.
IS456, (2000), Indian Standard Code ofPractice for Plain and ReinforcedConcrete, Bureau of Indian Standards, New Delhi.
SP 22 (S&T), (1982), Explanatory Handbook on Codes for Eartliquakc-Engineering - IS 1893:1975 and IS 4326:1976. Bureau of IndianStandards, New Delhi.
Next Upcoming TipHow do masonry buildingsbehave during earthquakes?
Authored by,I \ R MurtyIndian Institute1.1 leilinologv kanpurKanpur, India
Sponsored by:Building Materials ,\nd Uvhnnlngv Promotion(. oiiiu il. New I Vlhi. India
This release is a property of OT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eqtips/ifittk.ac. in. Visit www.nicee.org orwww.bmtpc.orB, to see previous IITK-BMTPC Earthquake Tips.
Febniary 2003
IITK - blnTPcEarthquake Tip
LearningEarthquake Designand
Construction
How do brick masonry houses behave during earthquakes?
Behaviour of Brick Masonry WallsMasonry buildings are brittle structures and one of
the most vulnerable of the entire building stock understrong earthquake shaking. The large number ofhuman fatalities in such constructions during the pastearthquakes in India corroborates this. Thus, it is veryimportant to improve the seismic behaviour ofmasonry buildings. A number of earthquake-resistantfeatures can be introduced to achieve this objective.
Ground vibrations during earthquakes causeinertia forces at locations of mass in the building.These forces travel through the roof and walls to thefoundation. The main emphasis is on ensuring thatthese forces reach the ground without causing majordamage or collapse. Of the three components of amasonrv building (roof, wall and foundation) (Figurela), the walls are most vulnerable to damage caused
Walls
Root
(a) Basic components of a masonry building
Pushed in the plane of the wall
Direction of
earthquake shaking
StrongDirection
Pushed perpendiculato the plane of the wall *ii?''Direction of
earthquakeshaking
rags*(b) Direction of force on a wall critically determines
its earthquake performance
Figure 1: Basic components of a masonrybuilding - walls are sensitive to direction ofearthquake forces.
by horizontal forces due to earthquake. A wall topplesdown easily if pushed horizontally at the top in adirection perpendicular to its plane (termed weakdirection), but offers much greater resistance if pushedalong its length (termed strong direction) (Figure lb).
The ground shakes simultaneously in the verticaland two horizontal directions during earthquakes(IITK-BMTPC Earthquake Tip 5). However, thehorizontal vibrations are the most damaging to normalmasonry buildings. Horizontal inertia force developedat the roof transfers to the walls acting either in theweak or in the strong direction. II all the walls are nottied together like a box, the walls loaded in their weakdirection tend to topple (Figure 2a).
To ensure good seismic performance, all wallsmust be joined properly to the adjacent walls. In thisway, walls loaded in their weak direction can takeadvantage of the good lateral resistance offered bywalls loaded in their strong direction (Figure 2b).Further, walls also need to be tied to the roof and
foundation to preserve their overall integrity.
Toppling
•': •': •':•': •*.••".• •": •".*•*; *i": •*.-•'.• •'.• •": •'.*•': •".* •",•': •".*•"
Direction of
earthquakeshaking
(a) For the direction of earthquake shaking shown,wall B tends to fail
Toothed jointsin masonry
courses
or L-shapeddowel bars
^<mmmm&^Direction of
earthquakeshaking
(b) WallB properly connected to Wall A (Note: roofis not shown): Walls A (loaded in strong direction)support Walls B (loaded in weak direction)
Figure 2: Advantage sharing between walls -only possible if walls are well connected.
IITK-BMTPC Earthquake Tip 12
P"Se -How do brick masonrv houses behave during earthquakes?Choice and Quality of Building Materials
Earthquake performance ofa masonry wall is verysensitive to the properties of its constituents, namelymasonry units and mortar. The properties of thesematerials vary across India due to variation in rawmaterials and construction methods. A variety ofmasonry units are used in the country, e.g., clay bricks(burnt and unburnt), concrete blocks (solid andhollow), stone blocks. Burnt clay bricks are mostcommonly used. These bricks are inherently porous,and so they absorb water. Excessive porosity isdetrimental to good masonry behaviour because thebricks suck away water from the adjoining mortar,which results in poor bond between brick and mortar,and in difficulty in positioning masonry units. For thisreason, bricks with low porosity are to be used, andthey must be soaked in water before use to minimisethe amount of water drawn away from the mortar.
Various mortars are used, e.g., mud, cement-sand,or cement-sand-lime. Of these, mud mortar is theweakest; it crushes easily when dry, flows outwardand has very low earthquake resistance. Cement-sandmortar zvilh lime is the most suitable. This mortar mix
provides excellent workability for laying bricks,stretches without crumbling at low earthquakeshaking, and bonds well with bricks. The earthquakeresponse of masonry walls depends on the relativestrengths of brick and mortar. Bricks must be strongerthan mortar. Excessive thickness of mortar is not
desirable. A 10mm thick mortar layer is generallysatisfactory from practical and aestheticconsiderations. Indian Standards prescribe thepreferred types and grades of bricks and mortars to beused in buildings in each seismic zone.Related IITK - bmlPC Earthquake TipTip5; Wliat are the seismic effects on structures?
Resource MaterialIS 1905, (1987), Indian Standard Code of Practice for Structural Use of
IInrtinfbnxd Masonry, Bureau of IndianStandards, New Delhi.IS 4326, (1993). Indian Standard Code of Practicefor Earthquake Resistant
Design nul i. onstruction <" fitiildmx Bureau ol hull,in Standards,New Delhi.
IS 13828, (1993), Indian Standard Guidelines for Improving EarthquakeResistance of Low-Strength Masonry Buildings, Bureau of IndianStandards. New Delhi.
Paulay.T., and Priestley.M.J.N., (1992), Seismic Design of ReinforcedConcrete and Masonry Buildings, John Wiley &Sons, New York.
Next Upcoming TipWhyshould masonry houses have simplestructural configuration?
How to Improve Behaviour of Masonry WallsMasonry walls are slender because of their small
thickness compared to their height and length. Asimple way of making these walls behave well duringearthquake shaking is by making them act together asa box along with the roof at the top and with thefoundation at the bottom. A number of construction
aspects are required to ensure this box action. Firstly,connections between the walls should be good. Thiscan be achieved by (a) ensuring good interlocking ofthe masonry courses at the junctions, and (b)employing horizontal bands at various levels,particularly at the lintel level. Secondly, the sizes ofdoor and window openings need to be kept small. Thesmaller the openings, the larger is the resistanceoffered by the wall. Thirdly, the tendency of a wall totopple when pushed in the weak direction can bereduced by limiting its length-to-thickness and height-to-thickness ratios (Figure 3). Design codes specifylimits for these ratios. A wall that is too tall or too longin comparison to its thickness, is particularlyvulnerable to shaking in its weak direction (Figure3).
Overturning
Thick Wall (I'.• brick)••'•ISUS
Thin Wall (1 brick)
Large portion of wa//not supported bycross walls
Cross Wall
Good support offered ,jrtby cross walls ™
overturning
Short Wall (/ brick)versus
Tall Wall (I brick)
Figure 3: Slender walls are vulnerable - heightand length to be kept within limits. Note: In thisfigure, the effect of roof on walls is not shown.
Authored by.U.Murtv
Indian Institute of Technology KanpurKanpur, India
Sponsored by:Building Materialsand Technology PromotionCouncil, New Delhi, India
This release is a properly of //T Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eqtips\aiitk.ac.in. Visit www.nicee.or^ orwww.bmtpc.org. to seeprevious IITK-BMTPC Earthquake Tips.
March 2003
IITK - bniliicEarthquake Tip
LearningEarthquake Designand
Construction
Why should masonry buildings have simple structural configuration:
Box Action in Masonry BuildingsBrick masonry buildings have large mass and
hence attract large horizontal forces during earthquakeshaking. They develop numerous cracks under bothcompressive and tensile forces caused by earthquakeshaking. The focus of earthquake resistant masonrybuilding construction is to ensure that these effects aresustained without major damage or collapse.Appropriate choice of structural configuration canhelp achieve this.
The structural configuration of masonry buildingsincludes aspects like (a) overall shape and size of thebuilding, and (b) distribution of mass and (horizontal)lateral load resisting elements across the building.Large, tall, long and unsymmetric buildings performpoorly during earthquakes (IITK-BMTPC EarthquakeTip 6). A strategy used in making them earthquake-resistant is developing good box action between all theelements of the building, i.e., between roof, walls andfoundation (Figure 1). Loosely connected roof orunduly slender walls are threats to good seismicbehaviour. For example, a horizontal band introducedat the lintel level ties the walls together and helps tomake them behave as a single unit.
Good
connection
between roof
and walls
'-mmm™**
_Roof that stays together as a single'integralunitduring earthquakes
Good connection
at wall corners
Figure 1: Essential requirements to ensure boxaction in a masonry building.
Walls with
small
openings
Good
connection
between
walls and
foundation
Influence of OpeningsOpenings are functional necessities in buildings.
However, location and size of openings in wallsassume significance in deciding the performance ofmasonry buildings in earthquakes. To understand this,
consider a four-wall system of a single storey masonrybuilding (Figure 2). During earthquake shaking, inertiaforces act in the strong direction of some walls and inthe weak direction of others (See IITK-BMTPCEarthquake Tip 12). Walls shaken in the weak directionseek support from the other walls, i.e., walls Bl and B2seek support from walls Al and A2 for shaking in thedirection shown in Figure 2. To be more specific, wallBl pulls walls Al and A2, while wall B2 pushesagainst them. At the next instance, the direction ofshaking could change to the horizontal directionperpendicular to that shown in Figure 2. Then, walls Aand B change their roles; Walls Bl and B2become thestrong ones and Al and A2 weak.
Thus, walls transfer loads to each other at their
junctions (and through the lintel bands and roof).Hence, the masonry courses from the walls meeting atcorners must have good interlocking. For this reason,openings near the wall corners are detrimental to goodseismic performance. Openings too close to wallcorners hamper the flow of forces from one wall toanother (Figure 3). Further, large openings weakenwalls from carrying the inertia forces in their ownplane. Thus, it is best to keep all openings as small aspossible and as far away from the corners as possible.
Inertia forcefrom roof
Inertia force
from roof
Direction of'""earthquake
shaking
Regionswhere load
transfer
takes placefrom one
wall toanother
Figure 2: Regions of force transfer from weakwalls to strong walls in a masonry building -wall B1 pulls walls A1 and A2. while wall B2pushes walls A1 and A2.
Cm k
IITK-BMTPC Earthquake Tip 13
Why should masonrv buildings have simple structural configuration? jmgel
Large windowopeningreduces thewall sbengthin its strong
Jion
Door opening close to wall comerweakens the connection between walls
Figure 3: Openings weaken walls in a masonrybuilding -a single closed horizontal band mustbe provided above all of them.
Earthquake-Resistant FeaturesIndian Standards suggest a number of earthquake-
resistant measures to develop good box-type action inmasonry buildings and improve their seismicperformance. For instance, it is suggested that abuilding having horizontal projections when seenfrom the top, e.g., like a building with plan shapes L,T,E and Y, be separated into (almost) simple rectangularblocks in plan, each of which has simple and goodearthquake behaviour (IITK-BMTPC Earthquake Tip 6).During earthquakes, separated blocks can oscillateindependently and even hammer each other if they aretoo close. Thus, adequate gap is necessary betweenthese different blocks of the building. The IndianStandards suggest minimum seismic separationsbetween blocks of buildings. However, it may not benecessary to provide such separations between blocks,if horizontal projections in buildings are small, say upto -15-20% of the length of building in that direction.
Inclined staircase slabs in masonry buildings offeranother concern. An integrally connected staircase slabacts like a cross-brace between floors and transfers
large horizontal forces at the roof and lower levels(Figure 4a). These are areas of potential damage inmasonry buildings, if not accounted for in staircasedesign and construction. To overcome this, sometimes,staircases are completely separated (Figure 4b) andbuilt on a separate reinforced concrete structure.Adequate gip is provided between the staircase towerand the masonry building to ensure that they do notpound each other during strong earthquake shaking.Resource MaterialIS 1905, (1987), Indian Standard Code of Practice for Structural Use of
Unreinfvrced Masonry, Bureau of Indian Standards, New Delhi.IS 4326, (1993), Indian Standard Code of Practice for Earthquake
Resistant Design and Construction of Buildings, Bureau of IndianStandards, New Delhi.
IS 13828, (1993), Indian Standard Guidelines for Improving EarthquakeResistance of Low-strength Masonry Buildings, Bureau of IndianStandards, New Delhi.
Tomazevic.M., (1999), Earthquake Resistant Design of MasonryBuildings, Imperial College Press, London, UK.
I
Damage
^Damage
(a) Damage in building with rigidly built-in staircase
Reinforced Concrete
Stair Case Tower.(or Mumty)
.nGap
j 1
(b) Building with separated staircase
Figure 4: Earthquake-resistant detailing ofstaircase in masonry building- must be carefully designed and constructed.
Related IITK - bmlPC Earthquake TipTip 5:What are theseismic effects onstructures?Tip 6:How architecturalfeatures affect buildings during earthquakes?Tipl2:Howbnck masonry houses behave during earthquakes?
Next Upcoming TipWhyare horizontal bands necessaryin masonrybuildings?
Authored by:( \ K.Murlv
Indian Institute of Technology KanpurKanpur. India
by:Building Materialsand Technology PromotionCouncil, New Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: catips>aiitk. ac.in. Visit www.nicee.org orwww.btnlpc.org, toseeprevious IITK-BMTPC Earthquake Tips.
April 2003
IITK - bnflpcEarthquake Tip
LearningEarthquake Designand
Construction
Why are horizontal bands necessary in masonry buildings?
Role of Horizontal BandsHorizontal bands are the most
earthquake-resistant feature in masonry buildings.Thebands are provided to hold a masonry building as asingle unit by tying all the walls together, and aresimilar to a closed belt provided around cardboardboxes. There are four types of bands in a typicalmasonry building, namely gable band, roof band, lintelband and plinth band (Figure 1), named after theirlocation in the building. The lintel band is the mostimportant of all, and needs to be provided in almost allbuildings. The gable band is employed only inbuildings with pitched or sloped roofs. In buildingswith flat reinforced concrete or reinforced brick roofs, theroof band is not required, because the roof slab alsoplays the role of a band. However, in buildings with
Masonry]above linten
Lintel Band
Masonrybelow lintel''
Plinth Band
CRoof
Foundation
(a) Building with Flat Roof
Gable-roof
connection
Floor-walls
connection
Plinth
important
3
Wall
connectionRHRNK'!*&:* io»
'•Peripheral wall'^•connection«m#>.'•<&<&<#&</.<&<:
(b) Two-storey Building with Pitched Roof
Figure 1: Horizontal Bands in masonry building -Improve earthquake-resistance.
flat timber or CGI sheet roof, roof band needs to beprovided. In buildings with pitched or sloped roof, theroof band is very important. Plinth bands areprimarily used when there is concern about unevensettlement of foundation soil.
The lintel band ties the walls together and createsa support for walls loaded along weak direction fromwalls loaded in strong direction. This band alsoreduces the unsupported height of the walls andthereby improves their stability in the weak direction.During the 1993 Latur earthquake (Central India), theintensity of shaking in Killari village was IX on MSKscale. Most masonry houses sustained partial orcomplete collapse (Figure 2a). On the other hand, therewas one masonry building in the village, which had alintel band and it sustained the shaking very well withhardly any damage (Figure 2b).
(b) A building with horizontal lintel band in Killarivillage: no damaqe
Figure 2: The 1993 Latur Earthquake (CentralIndia) - one masonry house in Killari village hadhorizontal lintel band and sustained the shakingwithout damage.
IITK-BMTPC Earthquake Tip 14
Why are horizontal bands necessary in masonry buildings? rw2
Design of Lintel BandsDuring earthquake shaking, the lintel band
undergoes bending and pulling actions (Figure 3). Toresist these actions, the construction of lintel bandrequires special attention. Bands can be made of wood(including bamboo splits) or of reinforced concrete(RC) (Figure 4); the RC bands are the best. The straightlengths of the band must be properly connected at thewall corners. This will allow the band to support wallsloaded in their weak direction by walls loaded in theirstrong direction. Small lengths of wood spacers (inwooden bands) or steel links (in RC bands) are used tomake the straight lengths of wood runners or steelbars act together. In wooden bands, proper nailing ofstraight lengths with spacers is important. Likewise, inRC bands, adequate anchoring of steel links with steelbars is necessary.
Small
^Bending ofLintel Band
Direction of
earthquakeshaking
I150
75 mm Umm
Cross-section of
Lintel Bands
Pulling ofLintel Band
Large
Figure 3: Bending and pulling in lintel bands -Bands must be capable of resisting these.
Indian StandardsThe Indian Standards IS:4326-1993 and IS:13828
(1993) provide sizes and details of the bands. Whenwooden bands are used, the cross-section of runners isto be at least 75mmx38mm and of spacers at least50mmx30mm. When RC bands are used, the minimum
thickness is 75mm, and at least two bars of 8mmdiameter are required, tied across with steel links of atleast omm diameter at a spacing of 150 mm centers.
Correct
Practices
Incorrect
Practice
(b) RC Band
Figure 4: Horizontal Bands in masonry buildings- RC bands are the best.
Related IITK - timlPC Earthquake TipTip 5: What are the seismic effects onstructures?Tipll:How brick masonry houses behave during earthquakes?Tipl3: Why masonry buildings should have simple structural
configuration?
Resource MaterialIAEE, (1986), Guidelines for Earthquake Resistant Non-Engineered
Construction, International Association for EarthquakeEngineering,Tokyo,availableon www.nicee.org.
IS4326, (1993), Indian Standard Code ofPractice for Earthquake ResistantDesign and Construction ofBuildings, Bureau of Indian Standards,New Delhi.
IS 13828, (1993), Indian Standard Guidelines for Improving EarthquakeResistance of Low-strength Masonry Buildings, Bureau of IndianStandards, New Delhi.
Next Upcoming TipWhy is vertical reinforcement required in masonry buildings?
Authored by.C.V.R.MmU
Indian Institute of 1echnology KanpurKanpur, India
Sponsored by:Building Materials and Technology PromotionCouncil, Nevi Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eatiosiaiitk.ac.in. Visit www.nicee.org orwww.bmtpc.org. toseeprevious IITK-BMTPC Earthquake Tips.
May2003
IITK - mmEarthquake Tip
LearningEarthquake Designand
Construction
Why is vertical reinforcement required in masonry buildings?
Response of Masonry WallsHorizontal bands are provided in masonry
buildings to improve their earthquake performance.These bands include plinth band, lintel band and roofband. Even if horizontal bands are provided, masonrybuildings are weakened by the openings in their walls(Figure 1). During earthquake shaking, the masonrywalls get grouped into three sub-units, namelyspandrel masonry, wall pier masonry and sill masonry.
Roof
SpandrelMasonry
Lintel
Wall Pier[Masonry
Level
Sill
Masonry
Sill
Level
Plinth
Level
Figure 1: Sub-units in masonry building - wallsbehave as discrete units during earthquakes.
Consider a hipped roof building with two windowopenings and one door opening in a wall (Figure 2a). Ithas lintel and plinth bands. Since the roof is a hippedone, a roof band is also provided. When the groundshakes, the inertia force causes the small-sizedmasonry wall piers to disconnect from the masonryabove and below. These masonry sub-units rock backand forth, developing contact only at the oppositediagonals (Figure 2b). The rocking of a masonry piercan crush the masonry at the corners. Rocking ispossible when masonrv piers are slender, and whenweight of the structure above is small. Otherwise, thepiers are more likely to develop diagonal (X-type)shear cracking (Figure 2c); this is the most commonfailure type in masonry buildings.
In un-reinforced masonry buildings (Figure 3), thecross-section area of the masonry wall reduces at theopening. During strong earthquake shaking, thebuilding may slide just under the roof, below the lintelband or at the sill level. Sometimes, the building mayalso slide at the plinth level. The exact location ofsliding depends on numerous factors includingbuilding weight, the earthquake-induced inertia force,the area of openings, and type of doorframes used.
^ Roof ^\>^
Roof
Band
/ Intel
Band Door
Opening mmm^
Window
Opening •
>. \
Foundation
Plinth-:-#;;#:-:^Band towhk^j Building Components Pier
Uplifting of •'.-.v.-:.-«.-r>\-v>s| 'masonry (b) Rocking of Masonry Piers
X-Crackingof Masonry
Piers P^^Foundation
rnm$mm®mm ^g«««^soFs(c) X-Cracking of Masonry Piers
Figure 2: Earthquake response of a hipped roofmasonry building - no vertical reinforcement
I is provided in walls.
Earthquake-induced inertia,force
Foundation
w8?Rj85888(8«SHPBBin
Roof
Sliding
Figure 3: Horizontal sliding at sill level in amasonry building - no vertical reinforcement.
IITK-BMTPC Earthquake Tip 15
Why is vertical reinforcement required in masonry buildings? W 2How Vertical Reinforcement Helps
Embedding vertical reinforcement bars in theedges of the wall piers and anchoring them in thefoundation at the bottom and in the roof band at the
top (Figure 4), forces the slender masonry piers toundergo bending instead of rocking. In wider wall piers,the vertical bars enhance their capability to resisthorizontal earthquake forces and delay the X-cracking.Adequate cross-sectional area of these vertical barsprevents the bar from yielding in tension. Further, thevertical bars also help protect the wall from sliding aswell as from collapsing in the weak direction.
Bendingof Pier
Vertical steel bars anchored in?
foundation and roof band
»WW«WWW»
j>
(a) Vertical reinforcement causes bending ofmasonry piers in place of rocking (See Figure 2).
(b) Vertical reinforcement prevents sliding in walls(See Figure 3).
Figure 4: Vertical reinforcement in masonry walls- wall behaviour is modified.
Protection of Openings in WallsSliding failure mentioned above is rare, even in
unconfined masonry buildings. However, the mostcommon damage, observed after an earthquake, isdiagonal X-cracking of wall piers, and also inclinedcracks at the corners of door and window openings.When a wall with an opening deforms duringearthquake shaking, the shape of the opening distortsand becomes more like a rhombus - two oppositecorners move away and the other two come closer.Under this type of deformation, the corners that comecloser develop cracks (Figure 5a). The cracks are biggerwhen the opening sizes are larger. Steel bars providedin the wall masonry all around the openings restrictthese cracks at the corners (Figure 5b). In summary,lintel and sill bands above and below openings, andvertical reinforcement adjacent to vertical edges,provide protection against this type of damage.
Earthquake-induced inertia force
Cracking
(a) Cracking in building with no corner reinforcement
Lintel Band
Sill Band(Similar toLintel Band,
but discontinuedat door openings)
mmm(b) No cracks in building with verticalreinforcement
Figure 5: Cracks at corners of openings in amasonry building - reinforcement around themhelps.
Reinforcement
Bars
Related IITK - bllPC Earthquake TipTip5: Whatare theseismic effects on structures?Tiptl: How brickinasonn/ houses behaveduring earthquakes?Tipl3: Whymasonrybuildingsshould have simplestructural
configuration?Tipli: Whyhorizontal handsare required in masonrybuildings?
Resource MaterialAmroseJ., (1991), Simplified Design ofMasonryStructures, John Wiley
&Sons, Inc., New York, USA.
BMTPC, (2000), Guidelines for Improving Earthquake Resistance ofHousing, Building Materials and Technology PromotionCouncil, New Delhi.
IS4326, (1993), Indian Standard Code ofPracticefor Earthquake ResistantDesign and Construction of Buildings, Bureau of Indian Standards,New Delhi.
IS 13828, (1993), Indian Standard Guidelines for Improving EarthquakeResistance of law-Strength Masonry Buildings. Bureau of IndianStandards, New Delhi.
Next Upcoming TipHow to improve seismic behaviour of stone masonry buildings?
Authored by:( V.R.Murt)Indian Institute oi rechnology KanpurKanpur, India
Sponsored by:Building Materials and rechnology PromotionCouncil, No\n Delhi. India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eatips'aiitk.ac. in. Visit www.nicce.org orwww.bmtpc.org, toseeprevious IITK-BMTPC Earthquake Tips.
lime 2003
IITK - timicEarthquake Tip
LearningEarthquake Designand
Construction
How to make Stone Masonry Buildings Earthquake Resistant?
Behaviour during Past Indian EarthquakesStone has been used in building construction in
India since ancient times since it is durable and locallyavailable. There are huge numbers of stone buildingsin the country, ranging from rural houses to royalpalaces and temples. In a typical rural stone house,there are thick stone masonry walls (thickness rangesfrom 600 to 1200 mm) built using rounded stones fromriverbeds bound with mud mortar. These walls are
constructed with stones placed in a random manner,and hence do not have the usual layers (or courses)seen in brick walls. These uncoursed walls have two
exterior vertical layers (called zoi/thes) of large stones,filled in between with loose stone rubble and mud
mortar. A typical uncoursed random (UCR) stonemasonry wall is illustrated in Figure 1. In many cases,these walls support heavy roofs (for example, timberroof with thick mud overlay).
Vertically splitlayer of wall
Hall-dressed
oblong stones
Vertical g-ip
Vertically split layerof wall
<h^ Mud mortar
^T^I Outward bulging
ol vertical wall
layer
Figure 1: Schematic of the wall section of atraditional stone house - thick walls without
stones that go across split into 2 vertical layers.
Laypersons may consider such stone masonrybuildings robust due to the large wall thickness androbust appearance of stone construction. But, thesebuildings are one of the most deficient buildingsystems from earthquake-resistance point of view. Themain deficiencies include excessive wall thickness,absence ol any connection between the two wythefi Olthe wall, and use of round stones (instead of shapedones). Such dwellings have shown very poorperformance during past earthquakes in India andother countries (e.g., Greece, Iran, Turkey, formerYugoslavia). In the 1993 Killari (Maharashtra)earthquake alone, over 8,000 people died, most ofthem buried under the rubble of traditional stone
masonry dwellings. Likewise, a majority of the over13,800 deaths during 2001 Bhuj (Gujarat) earthquake isattributed to the collapse of this type of construction.
The main patterns of earthquake damage include:(a) bulging/separation of walls in the horizontaldirection into two distinct un/thes (Figure 2a), (b)separation of walls at corners and T-junctions (Figure2b), (c) separation of poorly constructed roof fromwalls, and eventual collapse of roof, and (d)disintegration of walls and eventual collapse of thewhole dwelling.
(b) Separation of unconnected adjacent walls atjunctions
Figure 2: Major concerns in a traditional stonehouse - deficiencies in walls, roof and in their
connections have been prime causes for failure.
Earthquake Resistant FeaturesLow strength stone masonry buildings are weak
against earthquakes, and should be avoided in highseismic zones. The Indian Standard IS:13828-1993
states that inclusion of special earthquake-resistantdesign and construction features may raise theearthquake resistance of these buildings and reducethe loss of life. However, in spite of the seismicfeatures these buildings may not become totally freefrom heavy damage and even collapse in case of amajor earthquake. The contribution of the each ofthese features is difficult to quantify, but qualitativelythese features have been observed to improve theperformance of stone masonry dwellings during pastearthquakes. These features include:
IITK-BMTPC Earthquake Tip 16gggg 2How to make Stone Masonry Buildings Earthquake Resistant?
resistance, its extensive use is likely to continue due totradition and low cost. But, to protect human lives andproperty in future earthquakes, it is necessary tofollow proper stone masonry construction as describedabove (especially features (a) and (b) in seismic zonesIII and higher). Also, the use of seismic bands is highlyrecommended (as described in feature (c) above and inIITK-BMTPC Earthquake Tip 14).
(a) Ensure proper wall construction The wall thicknessshould not exceed 450mm. Round stone bouldersshould not be used in the construction! Instead, the
stones should be shaped using chisels andhammers. Use of mud mortar should be avoided in
higher seismic zones. Instead, cement-sand mortarshould be 1:6 (or richer) and lime-sand mortar 1:3 (orricher) should be used.
(b) Ensure proper bond in masonry courses: The masonrywalls should be built in construction lifts not
exceeding 600mm. Tltrough-stones (each extendingover full thickness of wall) or a pair of overlappingbond-stones (each extending over at least y-rthsthickness of wall) must be used at every 600mmalong the height and at a maximum spacing of 1.2malong the length (Figure 3).
Pal' of overlapping stoneseach ot length at least
Xths the wall thickness)
<450mm
Alternatives to
Through Stones
Wood
Plank ^^Hooked
steel link ^»y^-S-shaped p§
steel tie v
<4Q0mm
Figure 3: Use of "through stones" or "bondstones" in stone masonry walls - vital inpreventing the wall from separating into wythes.
(c) Provide horizontal reinforcing elements: The stonemasonry dwellings must have horizontal bands(See IITK-BMTPC Earthquake Tip U for plinth, lintel,roof and gable bands). These bands can beconstructed out of wood or reinforced concrete, andchosen based on economy. It is important toprovide at least one band (either lintel band or roofband) in stone masonry construction (Figure 4).
(d) Control on overall dimensions and heights: Theunsupported length of walls between cross-wallsshould be limited to 5m; for longer walls, crosssupports raised from the ground level calledbuttresses should be provided at spacing not morethan 4m. The height of each storey should notexceed 3.0m. In general, stone masonry buildingsshould not be taller than 2 storeys when built incement mortar, and 1 storey when built in lime ormud mortar. The wall should have a thickness of at
least one-sixth its height.Although, this type of stone masonry constructionpractice is deficient with regards to earthquake
Figure 4: Horizontal lintel band is essential inrandom rubble stone masonry walls -provides integrity to the dwelling, and holds thewalls together to resist horizontal earthquakeeffects.
Related IITK - tiMSc Earthquake TipTipl4: Why horizontal bands are required inmasonry buildings?
Resource MaterialBrzev,S., Greene.M. and Sinha.R. (2001), "Rubble stone masonry
walls with timber walls and timber roof," World HousingEncyclopedia 'www world-housint.net). India/Report 18,published by EERI and IAEE.
IAEE, (1986), Guidelines for Eartliquake Resistant Non-EngineeredConstruction, The ACC Limited, Thane, 2001 (See wiinv.niceeejxg).
IS 13828, (1993), Indian Standard Guidelines - Improving EarthquakeResistance of Low-Strength Masonry Buildings, Bureau of IndianStandards, New Delhi.
Publications of Building Materials and Technology Promotion Council,New- Delhi (imvw.hmlpc.org):(a) Retrofitting ofStone Houses in Marathwada Area ofMaharashtra(b) Guidelines For Improving Earthquake Resistance ofHousing(c) Manual for Repair and Reconstruction of Houses Damaged in
Earthquake in October 1991 in the Garhwal Region ofUP
Next Upcoming TipWhat are the seismic effects on RC frame buildings?
Authored by'.C.V.R.MurtyIndian Institute of Technology KanpurKanpur, India
Sponsored by:Building Materials and Technology PromotionCouncil, New Delhi, India
This release is a property of IIT Kanpur and BMTPC NewDelhi. It may be reproduced without changing its contentsand with due acknowledgement. Suggestions/commentsmay be sent to: eqtiDsUiiitk.ac.in. Visit www.nicee.org orwww.bmtpc.org. to seeprevious IITK-BMTPC Earthquake Tips
luly 2003
For more information, please write to:
The Head
Department of Civil Engineering
Indian Institute of Technology Kanpur
Kanpur 208 016
Tel: 0512 - 2597867; 2590151
Fax: 0512-2597395; 2590260; 2590007
E-mail: [email protected]
The Executive Director
Building Materials and Technology Promotion Council
Core-5A, First Floor, India Habitat Centre, Lodhi Road, New Delhi - 110 003
Tel: 91-11-2301 9367; 24638096; Fax: 91-11-2301 0145; 2464 2849
E-mail: [email protected]
Website: www.bmtpc.org