interface probes - qa techqatech.com/downloads/interface-probes/interfaceprobes.pdf · interface...
TRANSCRIPT
Ø.0538[1.367]
1.460[37.08]
.315 [8.00]Full Stroke
1.000 [25.40]
Ø.025 [0.64]
Ø.040 [1.02]Ø.056 [1.42]
Ø.0538[1.367]
1.310[33.27]
.250 [6.35]Full Stroke
Ø.122 [3.10]
.060 [1.52]
1.000 [25.40]
Ø.115 [2.92]
KEYSIGHT/AGILENT100-PRP4070L
KEYSIGHT/AGILENT100-PRP2519L
Ø.0538[1.367]
1.310[33.27]
.250 [6.35]Full Stroke
.040 [1.02]
1.000 [25.40]
Ø.062 [1.57]
.036 [0.91]
KEYSIGHT/AGILENT100-PRP2562L
Ø.070 [1.78] (typ)
100-
SDN2
53W
3-H
Ø.074 [1.88] (typ) Stop Ring
.139 [3.53] (typ).079 [2.01] (typ)
.039 [0.99] (typ)
1.080 [27.43]
(typ)
.164 [4.17]
100-
SDN2
53R5
-H
.947[24.05]
�.025[0.63]
Ø.025 [0.63]
Socket for Polarity Check and Test Jet
100 - PRP2519L 100 - PRP4070L
100 - PRG2503L
TUBE Letter Material/Finish Average Resistance
Current Rating1SS @ 204°C
P Nickel silver/ID precious metal clad < 15 mOhms 16.2 Amps
TIP STYLE Digit Material/Finish
19 Heat treated BeCu/plated gold over nickel
SPRING Letter Spring Force Preload @ 2/3 Stroke Material Cycle Life @ Stroke
L Low 1.3 [37] 3.5 [99] SS 1M @ .167 [4.24]
Please refer to page 37 for available sockets.
100 - PRP2562L
Interface Probes are used in testers for electromechanical contact between the fixture and tester. QA Technology has listed the part numbers that correspond with the applicable testers. These part numbers are QA’s recommended direct replacements.
KeySight/Agilent QA Probe/Socket Part NumberAll 3070 ICT Testers 100-PRP2519L/100-SDN253R5-H
Polarity Check 100-PRP2562L/100-SDN253W3-H
Test Jet 100-PRP4070L/100-SDN253W3-H
TUBE Letter Material/Finish Average Resistance
Current Rating1SS @ 204°C
P Nickel silver/ID precious metal clad < 15 mOhms 16.2 Amps
TIP STYLE Digit Material/Finish
62 Heat treated BeCu/plated gold over nickel
SPRING Letter Spring Force Preload @ 2/3 Stroke Material Cycle Life @ Stroke
L Low 1.3 [37] 3.5 [99] SS 1M @ .167 [4.24]
TUBE Letter Material/Finish Average Resistance
Current Rating1MW @ 120°C
P Nickel silver/ID precious metal clad < 20 mOhms 10.2 Amps
TIP STYLE Digit Material/Finish
70 Heat treated BeCu/plated gold over nickel
SPRING Letter Spring Force Preload @ 2/3 Stroke Material Cycle Life @ Stroke
L Low 0.8 [23] 3.0 [85] MW 1M @ .317 [8.05]
TUBE Letter Material/Finish Average Resistance
Current Rating1SS @ 204°C
G Nickel silver/OD gold plated < 15 mOhms 17.3 Amps
TIP STYLE Digit Material/Finish
03 Heat treated BeCu/plated gold over nickel
SPRING Letter Spring Force Preload @ 2/3 Stroke Material Cycle Life @ Stroke
L Low 1.3 [37] 3.5 [99] SS 1M @ .167 [4.24]
Interface Probes
DIRECT SALES (603) 926-0348 | SUPPORT (603) 926-1193 | FAX (603) 926-8701 | EMAIL: [email protected] | WWW.QATECH.COM46
45°(3)
43 - Chisel
30°
41 - Spear
45°(3)
43 - Chisel
60°
41 - Spear
Ø.0538[1.367]
1.310[33.27]
.250 [6.35]Full Stroke
Ø.062 [1.57]
50°(3)
1.000 [25.40]
45°(3)?
TERADYNE 100-PRG2503L
Ø.0538[1.367]
.855[21.72]
.730[18.54]
.125 [3.18]Full StrokeØ.040
[1.02]
60°
Ø.0538[1.367]
.880[22.35]
.730[18.54]
.150 [3.81]Full StrokeØ.040
[1.02]
Ø.0538[1.367]
.970[24.64]
.730[18.54]
.240 [6.10]Full Stroke
Ø.031 [0.79]
Ø.033 [0.84]
TERADYNE/GENRAD100-PL 15 -
TERADYNE/GENRAD100-PRG24 S-
TERADYNE/GENRAD100-PL 1241 -
Operating temp.: -55°C to 120°C1 Current Rating is affected by spring material and lubrication choices. Standard lubrication has a 204˚C maximum operating temperature limit. Before using probes near these current limits, please refer toCurrent Carrying Capacity and Operating Temperature Application Notes.
100-PL 1241 - 100 -PL 15 - 100 -PRG24 S-
TUBE
Letter Material/Finish Average Resistance
P Nickel silver/ID precious metal clad < 20 mOhms < 20 mOhms N/A
G Nickel silver/ID OD gold plated < 25 mOhms < 25 mOhms < 15 mOhms
N Nickel silver/No finish < 45 mOhms < 45 mOhms N/A
TIP
STYL
E Digit Material/Finish
41 Heat treated BeCu/plated gold over nickel, spear 41 41 41
43 Heat treated BeCu/plated gold over nickel, chisel N/A 43 43
SPRI
NG
Letter Spring Force Preload @ .107 Stroke Material Cycle Life @ Stroke
L Low 0.7 [20] 1.5 [43] SS 1M @ .107 [2.72] 1M @ .107 [2.72] N/A
S Standard 1.7 [48] 3.5 [99] SS 1M @ .107 [2.72] 1M @ .107 [2.72] N/A
S Standard 1.8 [51] 3.5 [99] SS N/A N/A 1M @ .200 [5.08]
H High 2.2 [62] 5.5 [156] MW 1M @ .107 [2.72] 1M @ .107 [2.72] N/A
X Extra 3.0 [85] 8.0 [227] MW 1M @ .107 [2.72] 1M @ .107 [2.72] N/A
U Ultra 4.5 [128] 10.0 [283] MW 250K @ .107 [2.72] 250K @ .107 [2.72] N/A
B High Preload 2.0 [57] 2.6 [74] SS N/A N/A 1M @ .200 [5.08]
OPTI
ON
Letter Description
B Curved probe tube (pylon replacement)
N No probe lubrication. Removing probe lubrication greatly reduces cycle life and should only be used in applications requiring operating temperatures below -55°C.
(blank) No option required
Teradyne/GenRad QA Part Number
1800 Series 7878, 8852, 8855 100-PRG2503L and/or 100-SDN250R
2270, 2271, 2272, 2282 (any model), 2283, 2284, 2286, 2287 built before 7/95 100-PLP1241S and/or 100-PLP1241S-B
2280, 2281, 2281a, 2287a 228x ICA (any model), 2283, 2284, 2286, 2287 built after 7/95 100-PLP1541S and/or 100-PLP1541S-B
Tester model numbers ending in “L” (high density capacity) 100-PRG2441S and/or 100-PLP1541S
Please refer to page 35 for available sockets.
Interface Probes
47All specifications subject to change without notice. All dimensions are in [mm]. All spring forces are oz [gm]. © 2017 QA Technology Company, Inc.