essentials - vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom...

6
Cooperative Plant Engineering web aucotec.com Essentials

Upload: others

Post on 13-Mar-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

Cooperative Plant Engineering

web aucotec.com

Essentials

Page 2: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

Plant engineering is characterized by large-scale projects with a large number of highly sophisticated engineering and management tasks. All those involved are under considerable time pressure. Quality must not fall by the wayside. This is your everyday life!

Fantastic and a reality: considerably reducing time pressure!How fantastic would it be to handle these multiple tasks much faster? Without error-prone data transfers and collaborations? With consistent cooperation of all participating disciplines, despite global distribution, despite different time zones, competences, languages and engineering cultures? With a modern cloud concept, with any time access to current data? Sounds fantastic - and is already a reality: with Engineering Base!

Versatile = parallel + integratedIts versatile data model creates unique integration, parallelism of editing and consistency for all core disciplines from FEED to process and detail engineering, plus retrofitting and maintenance. Conventional tool chains, in contrast, are not getting any shorter because of interfaces and synchronization platforms.

Cooperative by natureThe principle of parallel, even simultaneous working of all core disciplines on the same plant model ends the time-consuming as well as outmoded “relaying” of information. All data once developed can be used directly by all concerned, regardless of location, time or language. Only in this way does cooperation become efficient!

RFP & FEED

Electrical

Operation Process

Automation Instr. & C

3DOpen API

Open WebServices

DCS and Predictive MaintenanceAutomation

Simulation PDM, PLM, ERP

Alle hier aufgeführten Marken sind eingetragene Warenzeichen

Modern plant engineering is parallel

Circuit Diagram/14.6B

+IB01PMC-Cabinet 1

+IB02PMC-Cabinet 1

.E2-MU9CH2

.E2-MU9

+IV02Junction Box

++F1Field Range

(Ex

i) Zo

ne

+NB01E-switch cabinet 1

PIW 346Tr_RR

Temperature Control Reboiler

6

21

1514

22

21

1920

11

-W_NB01

-W010

-W_T132

ws1w s2 ge1 ge2

2x

22

22

Channel 2

ABBTH101

41+

42-

109

-K7

-X01

-X02

-X4

-X4

-X3

-X1

-T132Temperature Control ReboilerENDRESS & HAUSERTR24-B-2-2-D-B-2-B-

-W020

UB

21+

22-

23 24

21 22 23 24

91 01 11 2

91 01 11 2

BU RD GY YE

+-

TT

1R11R7

1R11

1R12

1R6

1R5

1R8

1R13

001

1R9

001

1R17

001

1R16001

001

1R2

1R25001

001

001

001

001Outlet Water (A) Inlet Water (A)

Inlet Water (B)

2) MeOH+N+OIL (Heated)

3) MeOH+N+OIL (Reacted)

.HCHeating Coil

1) MeOH+N+OIL

MeO

H (R

escu

ed)

16H

B02

F01C

1

1R3

N (2

)

Outlet Water (B)

Cooling System 1

Cooling System 2

MeOH

METHANOL

1V6

1V8

1V15

1V16

1V19

1V1

1V9

1V10

1V14

1V2

1V3

1V5

Reactor System

N (1)

NITROGEN

MeOH (Steam)

METHANOL

Blow Off Valve

Safety Shut-off Valve001

001

001

MeOH (Steam)

1V18

1B2

1V21

1B4

.RSReactor

.MTMethanol �elivering

1B1Methanol Tan�

1B4

1B3

TSA

002

TSA

001

TT

003TSA

005

LISA

006

TI TAH H

L

TAL

LSL

LAL

LAH

LSH

HHH

LLL

1N13.1

1N13.2

1N12.1

1N12.2

1N4.2

1N9.

2

1N9.

1

1N8.

2

1N8.

1

1N4.1

1N2.2

1N2.1

1N1.2

1N6.2

1N6.1

1N7.1

1N7.2

1N3.2

1N5

N10

N14

1N3.1

web aucotec.com

Page 3: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

Change consistentlyIn Engineering Base every modification is shown in each rep-resentation of the changed object - no waiting times, synchro-nization, crosschecks! Of course, this includes a sophisticated change management process. Thus, the versatile model always ensures the highest consistency of the overall documentation and makes Industry 4.0-compatible cooperation efficient.

It cannot be more digital than thatThe corresponding data model in Engineering Base also marks the highest level of digitization. Unlike storage in PDFs or DWGs, the model allows direct editing of all individual data. This makes them even more up-to-date and thus enhances their value - in the spirit of Industry 4.0.

Open to integrationIn addition to the parallelization of all core disciplines of plant engineering, the cooperative platform Engineering Base is also open for bidirectional connection of systems such as 3D, PLM or ERP. Once again, the versatile model pays off here as only one interface is necessary at a time. Numerous integrations are al-ready proven practice. It is just as easy to integrate the platform itself into any corporate IT.

No other system offers this versatility!

Fit for Industry 4.0

Unified plant data model

Single Database

Function Aspect

Function: Production

Function: Cooling water

Function: Level control

Location: Plant Field

Location: Prod. Building

Location: Tank farm

Location: Pump Station

Location: Control room

Equipment Aspect Location Aspect

FEED& Process Design 3D I&C Electrical

Device: Pump

Device: Tank

Device: Valve

Device: Sensor

Device: Junction Box

Device: Terminal Device: Wire

Device: Control cabinet

Device: Terminal

Device: Wire

1V1Hand Valve

1V13Hand Valve

1V16Hand Valve

1V11

Barrier to PCV

1V2NW25 PN16Hand Valveh

1V8NW25 PN16

Barrier bet. PCV

1V7Hand Valve

1R16HC10G01C1

1R220HB01M01B1

Air

Control Air

PI100

PI101

LI101PI

131

TI122

TIC103

1V9

1V12

1V17

1V5

Han

d Va

lve

1V6

Han

d Va

lve

1V3

Non

-Ret

urn-

Flap

Han

d Va

lve

Han

d Va

lve

Gas Preheater

1B1

P130

-M01

1B2

1V18

1X1

-51

CNG

Condensate

Air

H2O

Fluid Separator

1R520HC05M01B1

1R46HA01M01C1

1R610HB01K01B1

1R3100HA01M01B1

1V4Hand Valve

1V10Hand Valve

1V14Hand Valve

1V15Hand Valve

M

Conden. Recirculation Pump

Air

H2O

CNG

ARRIVEE GROUPE TR 11

11ADZ10CE011/012/0133*400kV/√33*100V/√3

0-10VA CI:0.5/3P0-10VA CI:0.2

Q90919

11ACZ10GS2001250A

T1-511ACZ10CE111/112/113

85D/1A30VA 5P20

T1-411ACZ10CE121/122/123

85D/1A20VA CI:0.2

T1-311ACZ10CE131/132/133

850/1A40VA 5P20

T1-211ACZ10CE141/142/143

85D/1A30VA 5P20

Q8091B11ACZ10GS600R

Q520915211ACZ10GS601

DCS

OSCILLO

F87BBAREVAMICOM P743

CENTRALE DE MESUREA V W VAR Hz

AREVAMICOM M231

P50ACTARISSL7000

F25AREVAKAVS 100

U BARRESAIGUILLEE

PP2

F21-2SIEMENS7SA522

F50/51AREVAMICOM P141

M

MM

VERS LA SYNCHROTG1

SYNkWhkVar

z U <>

>

>>

>

SF6/XLPE

XLPE/AIR

P2

BFfd

web aucotec.com

Page 4: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

web aucotec.com

With AUCOTEC’s cloud concept, it is possible to plan machines, plants and mobile systems with any scalability in the cloud. This not only offers exceptional flexibility, but also Industry-4.0-compatible networking.

Apps for the cloudThe concept also includes apps for special tasks. For example, for maintenance support, because mobility is particularly in demand here. The maintenance app enables Service to be on site quickly and to have all the necessary data at hand. This significantly reduces expensive downtime.

Another app example is the mobile inventory at the customer and transmission of it to EB, in order to derive new, individual optimization offers. The diverse special tasks of the users make many more apps conceivable. Thanks to Engineering Base, they are also feasible. Contact us!

Flexible and secureEngineering Base can be used independently of hardware and client installations on any possible terminal device. This allows users to offer the platform in-house as “Software as a Service” (SaaS). Of course, working in the private cloud is also possible with Engineering Base, i.e. as “Infrastructure as a Service” (IaaS).

This is how AUCOTEC makes globally distributed engineering even more flexible with state-of-the-art technology. The solution offers the highest possible data security, as it is based on Microsoft Cloud Azure Germany operated by T-Systems.

Without limits: engineering in the cloud

CAUSE

Del

ay

System

DESCRIPTION Syntax TAG NO Voting Note Delay ID 123456789 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40ESD 2.1 Activated LL-ESD2.1-E 17-InterConnection1 XXXXX X

2Smoke in area - Single Ref 1 02-Voted 1ooN (HH/LL/Alarm)2 :003 TX XXX XXXX TTSmoke in area (2 of N) - Not confirmedR ef 1 04-Voted 2ooN (HH/LL/Alarm)2 :004 TX XXX XXXX TTSmoke in area (3 of N) - ConfirmedR ef 1 Voted 3ooN (HH/LL/Alarm)1 5 XX XXX XXXX XX XX XXXXX X

Fire in area - Single6

Ref 2 01-Voted 1ooN (H/L/PreAlarm)2 :007 TX XXX XXXX TTFire in area (2 of N) Ref 2 04-Voted 2ooN (HH/LL/Alarm)8 XX XXX XXXX XX XX XXXXX X

9Fire Generator 1 Ref 3 04-Voted 2ooN (HH/LL/Alarm)1 0 XX XXX XXXX XX XX XFire Generator 2/3 Ref 4 04-Voted 2ooN (HH/LL/Alarm)1 1 XX XXX XXXX XX XX XFire Generator 4 Ref 5 04-Voted 2ooN (HH/LL/Alarm)1 2 XXXX XXXX XX XX X

1314

Manual call point - SingleR ef 6 02-Voted 1ooN (HH/LL/Alarm)1 5 XX XXX XXXX XX XX XXXXX X16

WIV Mode: HC Gas in duct - 20% LEL Ref 7 01-Voted 1ooN (H/L/PreAlarm)2 :001 7 TT XXXXX XXX TTWIV Mode: HC Gas in duct - 40% LEL Ref 7 02-Voted 1ooN (HH/LL/Alarm)1 8 XX XXXXX XXX XX XX XXXX XWIV Mode: HC Gas in duct - 2 of N - 20% LEL Ref 7 03-Voted 2ooN (H/L/PreWarning)1 9 XX XXXXX XXX XX XX XXXX X

20Ship Mode: HC Gas in duct - 20% LEL Ref 7 01-Voted 1ooN (H/L/PreAlarm)2 1 XXXXX XX XShip Mode: HC Gas in duct - 40% LEL Ref 7 02-Voted 1ooN (HH/LL/Alarm)2 2 XXXXX XX XShip Mode: HC Gas in duct - 2 of N - 20% LELR ef 7 03-Voted 2ooN (H/L/PreWarning)2 3 XXXXX XX X

24

FIRE & GASCAUSE AND EFFECTS

414-ER1

TAG

LL-E

SD

2.1-

C11

LL-E

SD

2.1-

C12

LL-E

SD

1.2-

C9

811I

B53

67L3

09

811I

B53

70L1

10

811I

B53

67B

407B

811I

B53

68B

407B

811I

B53

69B

407B

811I

B53

70B

405B

811I

B53

67L3

10

811I

B53

68L3

09

811I

B53

68L3

10

811I

B53

69L3

09

811I

B53

69L3

10

811I

B53

70L1

09

427X

YO

5600

STA

RT-

FP

WM

S T

. flo

od Z

one

2

817_

414X

YO

1501

0

425X

YO

4599

9

425X

YO

4599

8

425X

YO

1599

9

425X

YO

1599

8

ER

1 S

uppl

y da

mpe

r 3

ER

1 E

xhau

st d

ampe

r 1

ER

1 E

xhau

st d

ampe

r 2

ER

1 E

xhau

st d

ampe

r 3

817_

414X

YO

2501

0

817_

414X

YO

3501

0

ER

1 S

uppl

y da

mpe

r 1

ER

1 S

uppl

y da

mpe

r 2

Not

e

X

Page 5: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

Basic Engineering (FEED included)The versatile data model creates seamless continuity in plant design: it starts with the first overview flow diagram. The FEED function imports the results from simulations of Aspen and similar tools. Immediately PFDs and worksheets apply the results of the calculations. From the rough flow chart to the material balance, Engineering Base then automatically displays all the consequences of each desired scenario - each in a separate document.

Process EngineeringIn the process design, numerous user-friendly functions facilitate the development of the P&ID, for example through modular design. Lists and reports are created automatically. Added to this are pipe-class-related workflow and rule-based design. If FEED was used in basic engineering, the process design must “only” supplement its specifications in the scenario that was selected and commissioned.

Detail EngineeringInstrumentation, circuit diagram creation, wiring, terminal assignment, cabinet design, I/O specifications, in short: the entire infrastructure of everything that makes a plant functional

has been a core competence of AUCOTEC for over 30 years. In addition, the control system configuration is considerably accelerated: with automated transfer of the engineering data to the programming of every common control system, even in parallel to different systems.

Cause & EffectBefore commissioning, a plant will be put through its paces with Cause & Effect documents. This phase benefits once again especially from the uniform data model. Engineering Base draws all necessary logic specifications from each individual discipline and automatically creates the report matrix. This ensures unprecedented consistency and saves both important engineering capacity and a lot of time.

Plant Operation With the support of plant operation, the platform rounds off its integration principle. On the one hand it offers web-based maintenance functions with more mobility and quality, on the other hand a special management of execution measures for larger conversion and expansion projects. This ensures the orderly and exceptionally consistent return of the new data into the updated as-built project.

Unique spectrum: fully integrated

Pure synergy!This unique spectrum redefines your daily engineering life. Much faster project turnaround times, fewer mistakes and agreements, no unnecessary crosschecks and synchronization. All core disciplines united in a versatile data model in only one database. Your new everyday life: pure synergy!

web aucotec.com

Page 6: Essentials - Vogel · 2019-05-20 · areva micom p743 centrale de mesure a v w var hz areva micom m231 p50 actaris sl7000 f25 areva kavs 100 u barres aiguillee pp2 f21-2 siemens 7sa522

web aucotec.com

Worldwide supportBecause there are no limits to the application of our products, AUCOTEC is represented all over the world. Many of our customers are firms operating on a global scale.

Our global network is at your service around the clock, and in all languages - right from the word go.

Seize the opportunity and seize the lead – worldwide!

AUCOTEC AGOldenburger Allee 2430659 Hannover Germany

telefon | phone +49 511 61 03-0 [email protected]