electromechanical modelling of fusion cables

18
Presenter : Rebecca Riccioli 20/09/2021 Electromechanical modelling of fusion cables Alexandre Torre (CEA-IRFM) Marco Breschi (UNIBO-LIMSA) Damien Durville (ECS-MSSMat) Frédéric Lebon (AMU-LMA) Co-authors:

Upload: others

Post on 02-Jul-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Electromechanical modelling of fusion cables

Presenter : Rebecca Riccioli

20/09/2021

Electromechanical modelling

of fusion cables

Alexandre Torre (CEA-IRFM)

Marco Breschi (UNIBO-LIMSA)

Damien Durville (ECS-MSSMat)

Frédéric Lebon (AMU-LMA)

Co-authors:

Page 2: Electromechanical modelling of fusion cables

𝐼𝑐 = 𝐼𝑐 𝐵, 𝑇, 𝜀For Nb3Sn wires

| Page 2

Fusion cables

𝐼𝑐 = 𝐼𝑐 𝐵, 𝑇

Critical current

Superconducting conductors for tokamaks:

Cable-In-Conduit Conductors (CICCs)

Micro-filamentsComposite Nb3Sn wire

Images of P. Lee & C. Sanabria from NHMFL-FSU

Taken from: A. Devred et al 2014 Supercond. Sci. Technol. 27 044001

NHMFL-FSU

ITER TF CICCs

Taken from: Y. Ilyin et al 2007 Supercond. Sci. Technol. 20 186

Page 3: Electromechanical modelling of fusion cables

| Page 3

Electrical performance

ITER TF CICCs cyclic mechanical loadings due to:

Cool-down after manufacturing (923.15 K to 4.5 K)

Warm-up-cool-down during operation [ ~ 50-100 cycles ]

Electromagnetic cycles [ ~ 1000]

Lorentz force (68 kA, 11.78 T) ~ 80 t/m

Scaling up from strand to cable ? Performance degradation ?

Need for a tool able to understand and

predict the electrical performance of a

superconducting fusion cable

P. Lee & C. Sanabria

(NHMFL-FSU)

CIC Conductor

Nb3Sn wire

P. Lee & C. Sanabria

(NHMFL-FSU)

Taken from: M. N. Wilson, Oxford

Science Publications, 1993

Page 4: Electromechanical modelling of fusion cables

Further developments of the single

sub-cable model:

• MULTIFIL upgrade: deformable

“jacket” during CD;

• Jacket-cable thermal

equilibrium during CD;

• “Multi-petal” models during

EM cycles.

| Page 4

FE mechanical code:

MULTIFIL history2011

H. Bajas Ph.D.

Development of a first

mechanical model to

simulate fusion sub-cables

based on MULTIFIL code

developed by D. Durville:

• Material constitutive

laws implementation;

• Axial and transverse

validation;

• Deep analysis of the

ITER CS CICC and

main mechanical

phenomena.

But missing numerical

tools and phenomena:

representability ?

2017 2019 2020 2021

MULTIFIL

upgrade

Passage from

pseudo-periodic BCs

to hierarchical

handling of BCs:

Independency of the

ends BCs

MULTIFIL upgrade

&

Model improvement

Component 1

Component 1.1

Component 1.1.1

MULTIFIL upgrades:

• Twisted single sub-cable;

• Discrimination between

plastic and elastic strains

over strands;

Adding the jacket-cable

equilibrium for EM cycles.

MULTIFIL

upgrade

& new models

MULTIFIL upgrade

&

Model improvement

• MULTIFIL upgrade:

full ITER TF CICC

simulation;

• Other Nb3Sn cables

simulation: DTT TF

cable, JT60SA CS

cable, ITER CS STP

cable. 0 50 100 150-0.5

-0.4

-0.3

-0.2

-0.1

0

z [mm]

Eps

[%]

<EpsA>=-0.26081%<EpsAel

>=-0.10206%<EpsApl

>=-0.15876%

EpsA

EpsAel

EpsApl

1 EM

3 E

Ms

Page 5: Electromechanical modelling of fusion cables

| Page 5

ITER TF CICC simulation:

The shapingMULTIFIL allows to simulate the main phases of the conductor life starting from the manufacturing,

which is here the global shaping of the strands assembly.

6x[(2Nb3Sn +1Cu)x3x5x5+(3Cu)x4)]

The initial shape is given by the compaction of strands that follow

superposed helical trajectories. For each cabling stage, an helix is

defined and the result is the superposition of five helices.

Taken from: M. Breschi et al 2017

Supercond. Sci. Technol. 30 055007

The initial trajectories are the result

of the compaction by rigid tools

Page 6: Electromechanical modelling of fusion cables

| Page 6

ITER TF CICC simulation:

The shapingDesign:

Cosϑ = 0.97

VF = 29.7 %

Diam = 39.7 mm

Cosϑ = 0.988

Diam = 38.44 mm

VF = 29.7 %

Length = 300 mm

STRAIGHT PETAL

Cosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Straight Petal (SP)

Full Cable (FC)Twisted Petal (TP)

Cosϑ = 0.968

Diam = 38.8 mm

VF = 29.7 %

Length = 300 mm

TWISTED PETAL

Scaling up of the ITER TF

CICC model

Page 7: Electromechanical modelling of fusion cables

| Page 7

ITER TF CICC simulation:

The loadsAfter shaping the other critical phases of the conductor life are the Cool-Down (CD) and the EM

loadings.

Operating

temperature

Heat treatment

temperature

Steel and Nb3Sn wires

have different coefficients

of thermal expansion

(contraction in this case)

The cable work in a global state of

compression inside the conductor

EM cycle

Cool-Down

(CD)

Page 8: Electromechanical modelling of fusion cables

| Page 8

ITER TF CICC simulation:

The loadsAfter shaping the other critical phases of the conductor life are the Cool-Down (CD) and the EM

loadings.

EM cycle

Cool-Down

(CD)

1 EM

3 EM

The model

considers the

presence of the

jacket even if it is

not simulated

(68 kA, 11.78 T)

εCD = -0.61 %

Gradual compressive shifts of

jacket-cable equilibrium due

to EM load

Page 9: Electromechanical modelling of fusion cables

| Page 9

ITER TF CICC simulation:

Phenomenological studyCosϑ = 0.988

Diam = 38.44 mm

VF = 29.7 %

Length = 300 mm

STRAIGHT PETAL

Straight Petal (SP) EM cycle

Cool-Down

(CD)

Cool-Down

𝛾𝑏= 0.539η𝑝𝑙= 2.5

𝛾𝑏= 0.561η𝑝𝑙= 12.3

𝛾𝑏= 0.594

η𝑝𝑙= 46.3

After 1 EM cycle

After CD

After 4 EM cycles

(68 kA, 11.78 T)

εCD = -0.61 %

New identified

phenomenon: plastic

softening due to EM load

Page 10: Electromechanical modelling of fusion cables

| Page 10

ITER TF CICC simulation:

Parametric studyCosϑ = 0.988

Diam = 38.44 mm

VF = 29.7 %

Length = 300 mm

STRAIGHT PETAL

Straight Petal (SP) Mechanical exposure to

fracture as a function of the VF

Threshold around

~31 % of VF between

locked and loose

behavior.

Page 11: Electromechanical modelling of fusion cables

| Page 11

ITER TF CICC simulation:

Scaling-upCosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Full Cable (FC)

Full cable behavior =

tensile shift and broadening

(more exposure to tensile

strains fractures)

εCD = -0.61 %

εCD = -0.67 %

Full model VS Petal model mechanical

comparison ?

Page 12: Electromechanical modelling of fusion cables

| Page 12

ITER TF CICC simulation:

EM load on full cableCosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Full Cable (FC)

Bef

ore

EM

cy

cle

Pea

k E

M c

ycl

e

Rel

ease

EM

cy

cle

IxB

(68 kA, 11.78 T)

εCD = -0.67 %

The full cable model shows a

large displacement of the

wires during the EM cycle in

the low pressure side

Page 13: Electromechanical modelling of fusion cables

| Page 13

ITER TF CICC simulation:

full cable analysisFull Cable (FC)

-20 -10 0 10 20

-20

-10

0

10

20 <Cos()>=0.96188

0.93

0.94

0.95

0.96

0.97

0.98

0.99

1

-20 -10 0 10 20-20

-10

0

10

20 <Cos()>=0.96226

0.93

0.94

0.95

0.96

0.97

0.98

0.99

1

-20 -10 0 10 20-20

-10

0

10

20 <Cos()>=0.96131

0.93

0.94

0.95

0.96

0.97

0.98

0.99

1

-20 -10 0 10 20-20

-10

0

10

20

Vf estimate [%]

Vfmoy=29.7456 %

20

25

30

35

40

-20 -10 0 10 20-20

-10

0

10

20

Vf estimate [%]

Vfmoy=29.8402 %

20

25

30

35

40

-20 -10 0 10 20-20

-10

0

10

20

Vf estimate [%]

Vfmoy=29.7213 %

20

25

30

35

40

Cosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Cool-Down

924 K–5 KEM release

EM peak

(68 kA, 11.78 T)

Local cosϑ

Local VF

The local twist angle

shows a radial

gradient

The VF increases in

the low pressure zone

due to the application

of the EM cycle

IxB

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25

30

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25

30

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25

30

Contact forces

The strong contacts

tend to disappear in

the low pressure side

Page 14: Electromechanical modelling of fusion cables

| Page 14

ITER TF CICC simulation:

full cable local VFCosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Full Cable (FC)

Metallographic autopsies of full-scale ITER prototype

cable-in-conduit conductors after full cyclic testing in

SULTAN: III. The importance of strand surface

roughness in long twist pitch conductors

-3 -2 -1 0 1 2 3-10

-5

0

5

10

15

V

f devia

tion t

o n

om

inal [%

]

-3 -2 -1 0 1 2 3-10

-5

0

5

10

15

Vf

devia

tion t

o n

om

inal [%

]

-3 -2 -1 0 1 2 3-10

-5

0

5

10

15

Vf

devia

tion t

o n

om

inal [%

]

-20 -10 0 10 20-20

-10

0

10

20

Vf estimate [%]

Vfmoy=29.7182 %

20

25

30

35

40

IxB

The local VF

deviation from

average value as a

function of the

angular position

shows very good

agreement with the

experimental

measurements

Cool-Down

924 K–5 K

EM release

EM peak

(68 kA, 11.78 T)

Page 15: Electromechanical modelling of fusion cables

| Page 15

ITER TF CICC simulation:

full cable plasticizationCosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Full Cable (FC)

-20 -10 0 10 20

-20

-10

0

10

20

-4

-3.5

-3

-2.5

-2

-1.5

-1x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-4

-3.5

-3

-2.5

-2

-1.5

-1x 10

-3

Axial strain

-20 -10 0 10 20-20

-10

0

10

20

-3

-2.5

-2

-1.5

-1

-0.5

0x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-3

-2.5

-2

-1.5

-1

-0.5

0x 10

-3

Plastic axial

strain

Cool-Down

924 K–5 KEM release

-20 -10 0 10 20-20

-10

0

10

20

-4

-3.5

-3

-2.5

-2

-1.5

-1x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-3

-2.5

-2

-1.5

-1

-0.5

0x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-2

-1.5

-1

-0.5

0

0.5

1x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-2

-1.5

-1

-0.5

0

0.5

1x 10

-3

-20 -10 0 10 20-20

-10

0

10

20

-2

-1.5

-1

-0.5

0

0.5

1x 10

-3

The major effect of the

EM cycle is a global

plasticization of the

strain with major

localization in the low

pressure side of the cable Elastic axial

strain

EM peak

(68 kA, 11.78 T)

IxB

Page 16: Electromechanical modelling of fusion cables

| Page 16

ITER TF CICC simulation:

full cable breakageCosϑ = 0.967

Diam = 38.86 mm

VF = 29.8 %

Length = 150 mm

FULL CABLE

Full Cable (FC)

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25

Surface fraction

at ε > 0 %

Rf

a+b

a

a-b

irr

y

ylim

AfLRL

-20 -10 0 10 20-20

-10

0

10

20

0

5

10

15

20

25IxB

a

a-b

a+b

irr

y

ylim

AfHRL

Cool-Down

924 K–5 KEM releaseEM peak

(68 kA, 11.78 T)

The low pressure side is characterized

by more exposure to fractures and so

stronger decrease of Ic.

Breakage models:

• Low Resistivity Limit: - 10 % Ic

• High Resistivity Limit: - 20 % Ic

Page 17: Electromechanical modelling of fusion cables

Other conductors

ITER CS STP JT60SA CS DTT TF

Design:

Cosϑ = 0.945

VF = 33 %

Diam = 32.6 mm

Cosϑ = 0.945

Diam = 32 mm

VF = 33.5 %

Length = 300 mm

STP

STRAIGHT PETAL

Design:

Cosϑ = ?

VF = 34 %

Diam = 21 mm

Cosϑ = 0.922

Diam = 20.94 mm

VF = 34 %

Length = 300 mm

FULL CABLE

Design DTT:

Cosϑ = ?

VF = 26.4 %

Dim = 18.3 x 25 mm

Cosϑ = 0.9611

Dim = 18.3 x 25 mm

VF = 27.9 %

Length = 300 mm

FULL CABLE

Picture of JT60SA TFSL

| Page 17

Ready for

the scaling-

up to full

cable

Page 18: Electromechanical modelling of fusion cables

| Page 18

Thank you for

your attention !

Questions ??