    Welcome to the DriveWindow basics training module.

  • 8/19/2019 Drivewindow Basics

    2/34

    2

    Objectives

    Explain how to use DriveWindow for basic operations, e.g.

    Browsing and setting parameters

    Monitoring signals

    Datalogger settings

    Backup and restore functions

    Saving and downloading parameters

     © ABB GroupApril 4, 2011 | Slide 2

    Upon the completion of this module, you will be able to explain how to use DriveWindow for

    basic operations, such as setting parameters, monitoring signals, making settings for the

    datalogger, backing up and restoring functions, and saving and downloading parameters.

  • 8/19/2019 Drivewindow Basics

    3/34

    3

    DriveWindow operations

    A powerful PC tool for commissioning and maintenance of

    ABB drives Control operations (start, stop, references, etc.)

    Monitoring (signals and parameters)

    Handle parameters

    Data Logger (controls, display)

    Fault Logger (display faults, controls)

    All functions over network (control, monitoring, etc.)

     © ABB GroupApril 4, 2011 | Slide 3

    DriveWindow is a powerful PC tool for commissioning and maintenance of ABB drives.

    It lets you start and stop the drive, change the motor’s rotating direction, monitor signals, and

    handle parameters, as well as use several logger functions.

    You can also use DriveWindow to connect to drives via a local network.

  • 8/19/2019 Drivewindow Basics

    4/34

    4

    Hardware and software requirements

    IBM compatible PC

    Windows NT, 2000, XP, Vista or Windows 7 (2.30)

    1 free PCMCIA or PCI slot (with a PCI/PCMCIA adapter) or RUSB-02

    DDCS communication kit

    NDPA-02 PCMCIA-card (needs an NDPC adapter between the drive

    and the PCMCIA board)

    DDCS cabling

    Network adapter (when using a remote connection)

    NDPA-02 (PCMCIA)

    + NDPC-12 (10Mb)

    + RUSB-02 (10Mb)

    PCMCIA-adapter (PCI)

    + NDPA-02 (PCMCIA)

    + NDPC-12 (10Mb)

    + RUSB-02 (10Mb)

    OR

     © ABB GroupApril 4, 2011 | Slide 4

    DriveWindow is compatible with Windows NT, 2000, XP, VISTA and Windows 7.

    The PC needs a free card slot for a DDCS adapter card or USB connector for RUSB-02.

    Desktop PCs that only have PCI slots need an additional PCMCIA adapter.

    The drive also needs to have a DDCS adapter, RDCO, for communication.

    (If a PCMCIA card is used, an optic fiber connection adapter, NDPC, is required between the

    drive system and the PCMCIA board.)

  • 8/19/2019 Drivewindow Basics

    5/34

    5

    Connections

    Local

    Direct connection

    Through an optical distributor

    Ring

    Remote

    Network server

    Ring

    connection

    Network

    PC   Remote PC

    Drive communication links

    Drive communication links

     © ABB GroupApril 4, 2011 | Slide 5

    There are four possible ways to connect drives to DriveWindow.

    A direct connection means that one drive is connected to the PC (as described in the previous

    slide). On the other hand, multiple drives can be connected via an optical branching unit (NDBU)

    or by linking the drives into a ring network.

    There is also the possibility to connect drives and DriveWindow in a remote network. In that

    case, a remote PC acts as the server through which DriveWindow has full access to the drives.

  • 8/19/2019 Drivewindow Basics

    6/34

    6

    Local connections

    GOF =Glass

    Optic

    Fibre,

    HCS =Hard Clad

    Silica

    Fibre

    POF =Plastic

    OpticalFibre

    1CH 3

    DDCS

    GOF, HCS or POF

    HCS or POF

    ...8 7 6 0

    NDBU-95/85MSTR

    ...

    CH 3or 4

    2

    8 7 6 0

    NDBU-95/85MSTR

    CH 3or 4

    CH 3

    3

    CH 3CH 3

     © ABB GroupApril 4, 2011 | Slide 6

    A direct connection, or a point-to-point connection, is used between the PC and the drive if there

    is only one drive in the system. Several drives can be connected through optical distributors or

    by connecting them in a ring.

    The drive and the PC, or the PC and the distributor can be connected using glass optical fiber,

    hard clad silica fiber or plastic optical fiber. When the drives are connected through optical

    distributors, a DDCS protocol is used.

    Grid-side converter has DW connection to CH3 at RDCO-xx option board and generator-side

    converter to CH4 on AMC-33.

  • 8/19/2019 Drivewindow Basics

    7/34

    7

    GOF =Glass OpticFibre, Max1000m(NOCR-01required)

    HCS = HardClad SilicaFibre, Max200m

    POF =PlasticOptical

    Fibre, Max30m

    Set up unique driveaddresses in group 70

    1CH 3

    ...

    DDCS

    GOF, HCS or POF

    Opticaldistributor   8 7 6 0

    NDBU-95/85MSTR

    ...

    CH 3or 4

    2

    8 7 6 0

    NDBU-95/85MSTR

    HCS or POF CH 3or 4

    CH 33

    CH 3CH 3

    Constant power supply

    Ring

    1 = reserved for spare part

    use 76…127 = reserved foroptical distributors

     © ABB GroupApril 4, 2011 | Slide 7

    Local connections

    An optical distributor has 9 channels for chaining and connecting the drives. An NDBU-95

    distributor has nine 10 Mb optical channels and an NDBU-85 one 10 Mb channel for chaining

    and eight 5 Mb channels for connecting drives. Plastic optical fibers or hard clad silica fibers are

    used in connections. The distributors can be connected using different connection methods, for

    example in series, enabling connection for tens of inverters.

    A unique address has to be set in parameter group 70 for every drive in the link for

    communication. Note that address number 1 cannot be used if several drives are in a network

    as it is reserved for spare part use. The addresses from 76…127 are reserved for optical

    distributors. NDBU boards have a hardware switch for address setting.

    When the drives are connected in a ring, all the drives in the ring should have constant powersupply, otherwise the ring will break.

    With plastic cables the maximum distance is 20 meters for 5 Mb optical components, and 30

    meters for 10 Mb optical components. For longer distances a hard clad silica fiber must be used

    and then the maximum distance is 200 meters.

  • 8/19/2019 Drivewindow Basics

    8/34

    8

    Getting started

    Select a server and click OK.

     © ABB GroupApril 4, 2011 | Slide 8

    In the remainder of this module, we give an overview of Drive Window's user interface and basic

    functions.

    When DriveWindow is started, it first prompts to select which server to use. The ABB SMP

    server is the usual selection for working with a local drive. Other options include not connecting

    to any drive or connecting to a remote server.

  • 8/19/2019 Drivewindow Basics

    9/34

    9

    Browse Tree

    Item Sets

    Trend Settings

    Trend Display

    Getting started

     © ABB GroupApril 4, 2011 | Slide 9

    The main parts of the DriveWindow work area are the Browse Tree and Item Sets panes at the

    top, and the Trend Settings and Trend Display panes at the bottom.

    The Browse Tree pane is where you can see all the devices and parameter files that are

    available. Opening the various items, such as drives, in the Browse Tree lets you explore their

    parameters. By double-clicking the drive in the list, it will expand to show all the available tools

    of the unit.

    The Item Sets pane has various tabs which display parameters and signals. For instance, the

    Browsed tab contains parameters and signals of whatever is selected in the Browse Tree pane.

    In the Trend Settings pane, you can configure which signals are monitored, when they are

    monitored, and how.

    Monitored signals are displayed in the Trend Display pane to the right. The Trend Display

    actually consists of two displays depending on which tab is selected in the Trend Settings. The

    other is the Datalogger display of the currently selected datalogger.

    You can adjust the size of all the panes to fit whatever information is in them, but if the size is

    not big enough, then scrollbars will appear at the edges of the pane.

  • 8/19/2019 Drivewindow Basics

    10/34

    10

    The toolbars and status bar

    Status bar

    Drive Panel toolbar

    Title bar

    Standardtoolbar

    Monitor toolbar Logger toolbar

    DriveWindow User’s manual (large pdf-file)

     © ABB GroupApril 4, 2011 | Slide 10

    The other parts of the work area include the title bar, the various toolbars and the status bar.

    The title bar displays the names of the current server and the item selected in the Browse Tree.

    The status bar displays information on the state of the currently selected drive.

    You can access the most common commands for browsing, monitoring and logging from the

    three toolbars shown at the top.

    The Drive Panel toolbar, which is used to take control of the drive, is normally right above the

    status bar.

    The toolbars and status bar can individually be hidden or moved to different locations, but the

    appearance shown here is commonly used.

    You can find more detailed information on the buttons and menus in the DriveWindow User’s

    manual.

  • 8/19/2019 Drivewindow Basics

    11/34

    11

    Item sets

    • Parametersin a drive

    • Parametersin a file

    • Fault logs

    • Event logs

    • Monitoreditems

    • Dataloggeritems

    • Copy toclipboard

    • Monitored

    drive

     © ABB GroupApril 4, 2011 | Slide 11

    The item sets pane is the upper right pane within the window area. It consists of several item

    sets, one of which is visible at a time.

    You can use the pane for several purposes, such as

    • To view and change item values in a drive or in an open parameter file.

    • To view the contents of fault and event loggers in a user friendly way.

    • To add items to and remove items from the monitor or datalogger.

    • To change the drive of monitored items, and

    • To copy items to the clipboard.

    Although there are several types of item sets, they can be divided into two main categories:

    • Those that list items, and

    • Those that list faults or events.

  • 8/19/2019 Drivewindow Basics

    12/34

    12

    Adding item sets

    Context

    menu

     © ABB GroupApril 4, 2011 | Slide 12

    Instead of having fixed item sets, DriveWindow allows you to add, remove, and arrange item

    sets as well as change their properties.

    Adding an item set is done by selecting the Add New command from the Item Set submenu of

    the Desktop menu.

    The same submenu is included in the context menu, which you can access by right-clicking on

    the item sets pane outside the name of an item.

    You can add the following types of item sets:

    All parameters, which contains all un-protected parameters of the source drive.

    User items, which contains user-defined parameters and signals.

    Faults, which is used to view the contents of the source drive fault logger. By default, there is a

    predefined item set of this kind.

    Events, which is used to view the contents of the source drive event logger.

    All faults, which is used to view the combined contents of the fault loggers for all connected

    drives.

    All events, which is used to view the combined contents of the event loggers for all connected

    drives.

    The added item set is on the far right in the item sets pane and its tab is selected. You can

    rearrange the item sets, and you can also remove any item sets you’ve added.

  • 8/19/2019 Drivewindow Basics

    13/34

    13

    Item set properties

     © ABB GroupApril 4, 2011 | Slide 13

    Item set properties are shown and changed in dialog boxes. Each type of item set has properties

    of its own. So, contents of the dialog boxes depend on the type of the item set.

    To view and change properties of the currently shown item set, select the Properties command

    from the Item Set submenu of the Desktop menu or from the context menu.

  • 8/19/2019 Drivewindow Basics

    14/34

    14

    Item set properties

     © ABB GroupApril 4, 2011 | Slide 14

    Item set types of browsed, user defined, and all parameters have a Format tab in their Item Set

    Properties dialog box. This tab defines the format to be used in displaying the values of items in

    the item set.

    All types of item sets have the same General tab in their Item Set Properties dialog box. This tab

    contains general properties common to all types of item sets.

    Only user item sets have the Items tab in their Item Set Properties dialog box. This tab defines

    how the names of items are formed and what is displayed in case an item is not available.

  • 8/19/2019 Drivewindow Basics

    15/34

    15

    Item set properties

     © ABB GroupApril 4, 2011 | Slide 15

    The User defined item set, the All parameters item set, and the Faults, and Events sets all have

    the same Source tab in their Item Set Properties dialog box. This tab defines the drive whose

    values are displayed.

    The Faults, Events, All faults, and All events item sets have the Show tab in their Item Set

    Properties dialog box. In the show tab, you can filter which values are shown in these item sets.

  • 8/19/2019 Drivewindow Basics

    16/34

    16

    Warning: Selecting Local control stops normal operation immediately, without any

    warnings. Automation system can’t effect in Local control.

    The full drive panel toolbar (local control) is available only when the drive is in remote

    control mode (Local control is not selected from control panel or other computer).

    In the toolbar you can see the name and address of the selected drive.

    With the drive panel toolbar you can, for example, take and release control of the drive,

    clear faultlogger, edit and set the reference value, start and stop the drive, and change

    the direction of rotation.

    Drive panel toolbar

    1. Name and address of the selected drive

    2. Take/release control (Local/Remote)

    3. Clear faultlogger

    4. Reference edit field and reference value (DW 2.1)

    5. Set reference

    6. Step button (DW 2.1)

    7. Reset8. Start

    9. Stop

    10. Direction of rotation

    11. Coast stop

    1 2 3 4 5 6 7 8 9 10 11

     © ABB GroupApril 4, 2011 | Slide 16

    1 2 3

    Panel toolbar in remote mode,

    take control action stops normal operation

  • 8/19/2019 Drivewindow Basics

    17/34

    17

    Desktop preferences

    Specifyingdefault settings

    (for all ItemSets):

    Specifyingcustom settings(for individualItem Sets):

      Right-click

     © ABB GroupApril 4, 2011 | Slide 17

    The default behavior of how DriveWindow displays item sets is controlled by the Desktop

    Preferences. They are accessed from Preferences in the Desktop menu.

    First, it is good to check the Item Update setting, which specifies the default for how

    DriveWindow refreshes the values shown in the Item Sets pane.

    There are three options: from device, from cache and put on-line.

    From Device means that the item values are always fetched from the drives.

    From Cache means that the item values are fetched from a cache.

    The Put On-Line command means that item values are updated at regular intervals.

    Note, that the Desktop Preferences are default selections that an item set may or may not use.

    You can choose whether an item set really uses these defaults, or if it simply overrides them

    with its own settings. The defaults provide a quick way to make changes that apply to many

    places at once.

    To change the preferences for a specific item set, right click its tab in the item sets pane and

    select properties.

  • 8/19/2019 Drivewindow Basics

    18/34

    18

    Editing parameters

    (double-click)   (double-click)   (double-click)

    Write-protection

     © ABB GroupApril 4, 2011 | Slide 18

    Parameter values are edited in the Items Sets pane.

    For example, to change the constant speed selection, open parameter group 12 in the Browse

    Tree, and double-click parameter 12.01 in the Browsed set.

    Some items, such as signals, are write-protected. You can tell if the item is write-protected if the

    Change Value button in the toolbar is grayed out, or the computer beeps when you double-click

    it.

    (If the drive is running when you double-click a parameter group, editing some parameters is not

    possible. This so called READ ONLY-status remains even after the drive has been stopped. Inthat case, to make parameter editing possible:

    First, choose the option “Disconnect the Server” from the Network menu.

    Then, select the option “Network Servers” from the Network menu.

    An item list is displayed, that also includes a list of all parameters.)

  • 8/19/2019 Drivewindow Basics

    19/34

    19

    Reading actual signals

    Open group1

    Activate signals

    Online signals are shown inyellow

    Lock signals

    Activate/Deactivate

    Lock

     © ABB GroupApril 4, 2011 | Slide 19

    To read the actual signal values of the drive, open one of the Actual signal parameter groups,

    such as group 1, in the Browse Tree.

    Now you can see the signal values in that group in the Browsed set. However, signal values

    usually change continuously, so you may want to put some signals online by clicking the

    Activate button in the toolbar. For example, you could select the first signal in the list and put it

    online to make DriveWindow periodically refresh the value. Online signals are shown in yellow.

    Furthermore, you might also want to browse other parameters while still keeping the online

    signal visible in the Browsed set. You can lock the signal by clicking the Lock button in the

    toolbar.

    Note that many of the operations you do in DriveWindow apply to all currently selected items.So, you could, for instance, select all the signals that you want to observe by holding down the

    Control (or Shift) key while selecting them in the Item Sets pane, and then activate and lock

    them all with just a few mouse clicks.

  • 8/19/2019 Drivewindow Basics

    20/34

    20

    Monitoring signals

    Monitorsettings

    Graphpreferences

     © ABB GroupApril 4, 2011 | Slide 20

    In the next few slides we take a look at monitoring signals.

    To monitor signals make appropriate settings in the monitor tab and configure the graph

    preferences.

  • 8/19/2019 Drivewindow Basics

    21/34

    21

    Selecting monitored items

    Typical situation: monitor 5-6 channels

    Select signals, add Monitored Items

    Add monitored items

     © ABB GroupApril 4, 2011 | Slide 21

    There are usually 5-6 channels to monitor.

    Select the signals to be monitored from the Item Sets Pane and assign them to the

    channels by clicking the Add Monitored Items button in the toolbar.

  • 8/19/2019 Drivewindow Basics

    22/34

    22

    Monitor modes

     –  Normal (min. sampling interval10ms)

     –  Fast (min. 1ms)

    Monitoring interval (ms)

    History buffer (in seconds)

    Coordinate lengths (s)

    Scaling of each channel   = Can be set at any time

    = Can be set when monitoring is cleared

    = Can be set when monitoring is stopped or paused

    Settings and scaling

     © ABB GroupApril 4, 2011 | Slide 22

    There are two modes of monitoring: normal and fast.

    Normal is the mode you will almost always use.

    Fast mode is for monitoring real or integer type signals.

    The monitoring interval is the x-axis resolution.

    The data the monitor collects goes into a history buffer. The history buffer makes it possible to

    collect more data than fits on the screen.

    When the monitor is paused or stopped, you can browse the data in the history buffer. You can

    set the size of the buffer in seconds.

    The next three settings define the coordinate lengths.

  • 8/19/2019 Drivewindow Basics

    23/34

    23

    Graph preferences

    Graph appearance and settings

    How points are connected

    Graph scaling

    Are values shown with the graph cursor

    Show scaled/unscaled cursor values

     © ABB GroupApril 4, 2011 | Slide 23

    Graph preferences controls the trend display graph appearance and settings. It is accessed from

    the file menu. It has settings for printing, line colors and so on.

    The miscellaneous tab allows you to change how points in a graph are connected to each other,

    graph scaling and whether or not to show scaled or unscaled values with the graph cursor.

    The scaling method defines how the coordinate axes are scaled. The options are coefficient and

    offset and values at 100 and 0.

  • 8/19/2019 Drivewindow Basics

    24/34

    24

    Operating the monitor

    Use the monitor toolbar to

    1. Add/remove item2. Start/continue monitoring

    3. Stop monitoring

    4. Pause monitoring

    5. Clear monitoring

    From the file menu

    Open or save the graph

    Comment or print the graph

    Export data

    Copy graph into the clipboard

    Set graph preferences

     © ABB GroupApril 4, 2011 | Slide 24

    The monitor toolbar is where you also start and stop monitoring the signals you have selected.

    You can also pause the monitor temporarily to take a closer look at a signal.

    From the File menu, you can save a graph to a file, or export the data to Excel, for instance.

  • 8/19/2019 Drivewindow Basics

    25/34

    25

    Workspace

     © ABB GroupApril 4, 2011 | Slide 25

    Workspaces allow you to save your preferences and pane arrangements such as the items

    shown in the browsed item set and their status.

    By doing this you can quickly setup DriveWindow to show the signals and parameters you

    desire.

    You can interrupt your work and then easily continue from the point you left off by restoring your

    saved workspace settings.

    You can create different personalized workspace sets.

  • 8/19/2019 Drivewindow Basics

    26/34

    26

    Fault logger

    Browsing thefault history

    Opening theFault logger

    Log 00 =most recentlog

    Updatingvalues

    Clearing thefault logger

    OFF-LINE or COMM. BREAKNOT RUNNING

    RUNNING (forward)

    FAULT

    WARNING

    DRIVE STATUS

     © ABB GroupApril 4, 2011 | Slide 26

    DriveWindow allows you to browse the fault history of the drive.

    The icon at the top of the browse tree shows the status of the drive, if the feature has not been

    turned off. If the drive has tripped on a fault the drive icon has an exclamation mark on it.

    You can view the contents of the fault logger in the drive by opening the fault logger item in the

    browse tree or by selecting the fault tab in the item sets pane.

    The fault set contains the description, time, status, etc.

    Log 00 is the most recent fault log.

    If the fault items are offline the values may be very old so you have to update them manually by

    clicking the UPDATE ITEMS button in the toolbar.

    You can clear the fault logger by clicking the Clear Faultlogger button in the Drive panel toolbar.

  • 8/19/2019 Drivewindow Basics

    27/34

    27

    Saving a parameter file

    1.Savingparameter

    files (withcomments)

    2.Downloadinto a drive

    3.Compare toother files

    4.Export tootherapplications

     © ABB GroupApril 4, 2011 | Slide 27

    With DriveWindow it is possible to save user and ID run result parameters into a file.

    You can use the saved parameters to download them into a drive or to compare them with

    current parameters of a drive and other parameter files. And you can export the parameter files

    for use in other applications.

  • 8/19/2019 Drivewindow Basics

    28/34

    28

    Restoring parameters

    Open the fileand select the

    drive

    Select

    Downloadcommand andthen theRestore type

     © ABB GroupApril 4, 2011 | Slide 28

    To download a parameter file to the drive, open the file and select Download from the File

    menu. DriveWindow checks the software version differences between the file and the drive. Ifdifferences are found, a warning is presented.

    Then you select whether to download the user data or ID run result, or both.

    Restore ID run results is usually selected if the file includes specifications of the motor

    connected to the drive. The parameters are downloaded to the drive’s RAM. If the drive is

    restarted, they will disappear, unless you force them into the Flash memory.

    The parameters are downloaded to the drive’s RAM and into the Flash memory.

    After the download is complete, DriveWindow prompts you to restart the drive.

    You should check using the Compare-function that there are no differences between the drive

    and the file.

  • 8/19/2019 Drivewindow Basics

    29/34

    29

    Creating a backup of the motor control board

    System

    Software >

    New >BackupPackage

    SystemSoftware >

    Backup

    System

    Software >Save As…

     © ABB GroupApril 4, 2011 | Slide 29

    To create a backup of the motor control board, create a new backup folder by selecting New >

    Backup package.

    Next, select Backup under System software which opens the Select drives dialog box.

    Select the drives you want to back up and click Backup to confirm.

    Once the backup is completed you will need to save the Backup package.

    Note that when this function is used, DriveWindow has to be updated with the service pack

    which can be found from the internet.

  • 8/19/2019 Drivewindow Basics

    30/34

    30

    Restoring the motor control board

    SystemSoftware >

    OpenSystemSoftware >Restore

    SystemSoftware >

    Close

     © ABB GroupApril 4, 2011 | Slide 30

    Then, to restore a backup package, first open the package file by selecting Open from the

    System Software menu.

    Then, select Restore, and choose which drive to restore and from which backup to restore it.

    Finally, close the backup package.

  • 8/19/2019 Drivewindow Basics

    31/34

    31

    Overview of the Datalogger

    LocationOf TheDatalogger

    Control Of The Datalogger

    DriveWindow

    Channel 1 Channel 3 Channel 4Channel 2

    Value 1

    Value 2

    Value 1

    Value 2

    Value 1

    Value 2

    Value 1

    Value 2

    Value nValue nValue nValue n

     © ABB GroupApril 4, 2011 | Slide 31

    The data logger is a digital oscilloscope inside the drive, which lets you record data from the

    drive in the most accurate way. You can control it with DriveWindow, and display the recorded

    data as a graph or save it to a file.

    A drive can have several dataloggers depending on the control board.

    The data logger can record data in four different channels and can contain up to 1024 samples.

    Each channel can record 256 samples (ACS600, ACS800), so it gives the possibility to record

    512 samples per signal using two channels. For example, channel 1 can be set to record the

    actual speed. The speed can be used as a triggering variable, with the rising or falling edge as

    the trigger, and with a selectable level.

  • 8/19/2019 Drivewindow Basics

    32/34

    32

    Datalogger settings

    Status of the drive and the reason whythe datalogger was triggered are shown

    Interval and pre-trigger time (ms)

    Trigger conditions, variable, level and

    hysteresis

     © ABB GroupApril 4, 2011 | Slide 32

    The Datalogger settings pane shows the status of the logger, and the reason why the logger

    was triggered.

    Here you can change the dataloggers sample interval, pre-trigger time, trigger conditions and so

    on.

    The pre-trigger time sets how many samples the logger keeps before the triggering point.

    The condition sets the event that triggers the logging, for instance a fault or a rising edge of a

    signal.

    The trigger variable tells the datalogger, which of the drive signals or parameters to use as the

    trigger when using level triggering.The Level tells the datalogger at what signal level to trigger.

  • 8/19/2019 Drivewindow Basics

    33/34

    33

    Datalogger example

    1. Delete signals

    2. Select the new signal

    3. Add the signal to the datalogger4. Make your datalogger settings

    5. Start the datalogger

    6. Upload the data from the datalogger

    7. View the recorded data 3

    2

    5

    6

    4

    7

     © ABB GroupApril 4, 2011 | Slide 33

    1

    Here is an example of how the Datalogger is used.

    Data read into DriveWindow must be cleared before new data can be downloaded.

    Delete the existing signal from the Datalogger and select the new signal as shown.

    By clicking the add symbol in the toolbar, add the signal to the datalogger.

    Next, make your datalogger settings. Scaling, such as the x-axis length can be done after the

    upload.

    Then start the datalogger.

    Once the Status value shows that the datalogger has been filled, you can upload the data from

    the datalogger.

    The recorded data can be viewed in the trend display.

    When you are finished viewing uploaded data, you can clear the datalogger graph. Clearing the

    graph enables you to change datalogger settings, if the datalogger is not running.