Report No.: PCANL191211002-01-M1
PC-EE-23-a
Page 1 of 17
Test Report
Client Name : HONOURTEK,INC.
Address : 2901 Tasman Dr#107 Santa Clara,CA95054
Product Name : HONOURTEK COB
Date : 2021-08-11
Shenzhen Anbotek Pengcheng ComplianceLaboratory Limited
Report No.: PCANL191211002-01-M1
PC-EE-23-a
Page 2 of 17
Report No.: PCANL191211002-01-M1
Product Description: HONOURTEK COB
Model No.: HRA1430-27-80-37-A000-F1
Test Initiation Date: 2015-12-09
Test Completion Date: 2017-04-22
Test Standard: IES LM-80-15
Test Laboratory: Shenzhen Anbotek Pengcheng Compliance Laboratory Limited
Testing location: Floor1, Building 1, SEC Industrial Park, No.0409 Qianhai Road, NanshanDistrict, Shenzhen, Guangdong, China
Tested by Reviewed by
Alcander Lou / Flora Zhang/
Note: This test report is prepared for the customer shown above and for the device described herein. It may not
be duplicated or use in part without prior written consent from Shenzhen Anbotek Pengcheng Compliance
Laboratory Limited. This report must not be used by the customer to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.
Note: The report was based on the original report SZANL181205001-01, only model numberupdated.
Report No.: PCANL191211002-01-M1
PC-EE-23-a
Page 3 of 17TABLE OF CONTENTS1 General Information........................................................................................................................................32 Summary of Test Result................................................................................................................................53 Test Method......................................................................................................................................................6
3.1 Photometric and Electrical Measurement.......................................................................................... 63.2 Season the LED from 0 hours to 12000 hours..................................................................................6
4 Test Data............................................................................................................................................................74.1 Data Set 1: 55°C, 1440 mA (Lumen Maintenance).......................................................................... 74.2 Data Set 1: 55°C, 1440 mA (Chromaticity Shift)...............................................................................94.3 Data Set 2: 85°C, 1440 mA (Lumen Maintenance)........................................................................ 104.4 Data Set 2: 85°C, 1440 mA (Chromaticity Shift).............................................................................114.5 Data Set 3: 105°C, 1440 mA (Lumen Maintenance)......................................................................124.6 Data Set 3: 105°C, 1440 mA (Chromaticity Shift)...........................................................................13
5 TM-21 Projection........................................................................................................................................... 146 EUT Photo....................................................................................................................................................... 15
Report No.: PCANL191211002-01
PC-EE-23-a
Page 4 of 17
1 General Information
1.1 Product Description for Device under Test (DUT)
Family products covered by this report:
According to ENERGY STAR® Requirements for the Use of LM-80 Data, the followingproducts can be covered by this report base on the information and declaration provided bymanufacturer. The information of these models shows that the covered products meet allsection 4 requirements of ENERGY STAR® Requirements for the Use of LM-80 Data(September 28, 2017)
This report covers the following models:
ModelNumber
Productfamilymodel
CCT(K) Luminoussurface
diameter(mm)
Luminoussurface
area(mm2)
MaximumCurrent(mA)
Substratearea(mm2)
Voltage(V)
HRA1430 Modeltested 2700-5000 14 153.86 1440 17.85×17.85×1.2 36
HRB1430 Modelcovered 2700-5000 14 153.86 1440 17.85×17.85×1.2 36
HRB1220 Modelcovered 2700-5000 12 113.04 1050 17.85×17.85×1.2 36
HRB1216 Modelcovered 2700-5000 12 113.04 960 17.85×17.85×1.2 36
HRA0930 Modelcovered 2700-5000 9 63.585 1440 15.85×15.85×1.2 36
HCB0920 Modelcovered 2700-5000 9.8 75.3914 960 13.5×13.5×0.9 36
HRA0920 Modelcovered 2700-5000 9 63.585 1050 15.85×15.85×1.2 36
HRB0913 Modelcovered 2700-5000 9 63.585 720 15.85×15.85×1.2 36
HRB0912 Modelcovered 2700-5000 9 63.585 600 15.85×15.85×1.2 36
Part Number: HRA1430-27-80-37-A000-F1
Part type: HONOURTEK COB
Nominal CCT: 2700K
Nominal CRI: 80
Nominal Input Power(W): 30W
Mean Initial Forward Voltage(V): 36V
Report No.: PCANL191211002-01
PC-EE-23-a
Page 5 of 17HRB0910 Model
covered 2700-5000 9 63.585 550 15.85×15.85×1.2 36
HRB0907 Modelcovered 2700-5000 9 63.585 375 15.85×15.85×1.2 36
HRA0613 Modelcovered 2700-5000 6 28.26 700 13.35×13.35×1.2 36
HRA0610 Modelcovered 2700-5000 6 28.26 540 13.35×13.35×1.2 36
HRA0607 Modelcovered 2700-5000 6 28.26 375 13.35×13.35×1.2 36
HRB0604 Modelcovered 2700-5000 6 28.26 250 13.35×13.35×1.2 36
HRA0410 Modelcovered 2700-5000 4.6 16.6106 450 13.35×13.35×1.2 36
HRA0407 Modelcovered 2700-5000 4.6 16.6106 375 13.35×13.35×1.2 36
HRA0404 Modelcovered 2700-5000 4.6 16.6106 250 13.35×13.35×1.2 36
HRA0303 Modelcovered 2700-5000 3.5 9.61625 180 11×11×1 36
HRS0303 Modelcovered 2700-5000 3.5 9.61625 180 7*7 36
Report No.: PCANL191211002-01
PC-EE-23-a
Page 6 of 17
1.2 Standards Used
IESNA LM-80-15: IES Approved Method for Measuring Luminous Flux and Color Maintenance ofLED, Arrays and Modules.
ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module LumenMaintenance Performance Data Supporting Qualification of Lighting Products (This test method wasnot accredited by NVLAP)
1.3 Test Facility Description
The test facility used by Shenzhen Anbotek Pengcheng Compliance Laboratory Limited is located atZone B, 1/F., Building 2, Hengchangrong High-Tech Industrial Park, Huangtian, Hangcheng Street,Bao'an District, Shenzhen, Guangdong, China.
1.4 Test Equipment List
Device Manufacture Model No. Serial No. Calibration Date Calibration DueDate
Digital PowerMeter YOKOGAWA WT210 SE-074 2019-05-07 2020-05-06
LM-80 Aging TestSystem KEYI KY-3X-LH60 SE-564 2019-05-07 2020-05-06
DC Power Supply EVERFINE WY605 SE-605 2019-05-07 2020-05-06
Standard Lamp EVERFINE D062 SE-606 2019-05-07 2020-05-06
SpectrumAnalyzer EVERFINE HAAS-2000 SE-607 2019-05-07 2020-05-06
Integrating Sphere(0.5m) EVERFINE AIS-2 SE-608 Before use Before use
Report No.: PCANL191211002-01
PC-EE-23-a
Page 7 of 17
2 Summary of Test Result
Data Set 1 2 3Nominal case temperatures 55°C 85°C 105°C
Drive Current 1440 mA 1440 mA 1440 mA
Condition
Ts=54.1°CTa=53.2°CR.H.<65%IF=1440 mA
Ts=83.9°CTa=83.1°CR.H.<65%IF=1440 mA
Ts=104.3°CTa=103.5°CR.H.<65%IF=1440 mA
sample size 25 25 25
Duration (in Hours) 12000 12000 12000
Intervals (in Hours) 1000 1000 1000
Failures Observed 0 0 0
Average Lumen Maintenance at 12000h 95.8% 94.9% 94.7%
Average Chromaticity Shift at 12000h 0.0040 0.0043 0.0047
Reported L70(12000h) TM-21 Lifetime >72000 >72000 >72000
Reported L80(12000h) TM-21 Lifetime 56000 50000 50000
Reported L90(12000h) TM-21 Lifetime 27000 23000 23000
Report No.: PCANL191211002-01
PC-EE-23-a
Page 9 of 17
3 Test Method
3.1 Photometric and Electrical Measurement
Total light output (luminous flux) for the 25°C±1°C ambient temperature conditions is measured using
a integrating sphere. Each LED is operated at rated drive current (DC Mode).
The total uncertainty of the light output measurements is estimated, at the 95% confidence level, not
to exceed±1.6% over the wavelength range 380-800nm.
3.2 Season the LED from 0 hours to 12000 hours
Three LM-80 aging measurement system Temperature Chambers are using for Seasoning, and the
temperature is set to 55°C, 85°C, 105°C (manufacture defined), the airflow is minimum to keep the
uniformity to temperature. LED are operated steady state (no cycling) for a period of 12000 hours,
checked the lumen flux and Chromaticity Shift every 1000 hours. The samples are inspected at
regular intervals (24 hours) throughout the 12000 hours. The time and date of failure of each lamp is
recorded. The actual elapsed time for each light LED is in hour.
Report No.: PCANL191211002-01
PC-EE-23-a
Page 10 of 174 Test Data4.1 Data Set 1: 55°C, 1440 mA (Lumen Maintenance)
Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 54.1℃
Ambient Temperature: 53.2℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Lumen Maintenance (%)
SampleNo. VF(V) Φ(lm) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L1 36.22 5489.9 101.2% 100.0% 99.9% 98.9% 98.6% 98.2% 97.8% 97.1% 96.1% 96.1% 96.1% 95.8%
L2 36.04 5366.7 100.0% 100.0% 99.7% 98.9% 98.6% 98.2% 97.7% 97.2% 96.1% 96.1% 95.8% 95.8%
L3 36.34 5486.6 104.0% 100.0% 99.2% 98.8% 98.5% 98.1% 97.5% 96.9% 96.3% 96.0% 96.1% 95.8%
L4 36.15 5440.4 103.8% 100.0% 99.6% 99.0% 98.4% 98.2% 97.6% 96.9% 96.1% 96.1% 96.0% 95.7%
L5 36.34 5518.2 101.5% 100.0% 99.4% 99.0% 98.4% 98.0% 97.8% 96.9% 96.3% 96.1% 95.9% 95.8%
L6 36.26 5436.2 101.8% 100.0% 99.4% 98.8% 98.5% 97.9% 97.7% 97.2% 96.1% 96.1% 96.0% 95.8%
L7 36.02 5386.3 102.4% 100.0% 98.9% 98.8% 98.6% 98.2% 97.5% 96.9% 96.3% 96.0% 96.1% 95.7%
L8 36.16 5421.5 101.1% 100.0% 99.6% 98.9% 98.3% 98.3% 97.6% 96.9% 96.4% 96.1% 96.0% 95.8%
L9 36.38 5455.9 101.7% 100.0% 99.6% 98.8% 98.5% 98.1% 97.5% 96.9% 96.4% 96.1% 96.0% 95.8%
L10 36.17 5380.7 101.1% 100.0% 99.5% 99.0% 98.7% 98.2% 97.5% 96.9% 96.4% 96.0% 96.1% 95.8%
L11 36.09 5340.4 101.3% 100.0% 98.9% 98.8% 98.5% 98.2% 97.8% 97.0% 96.5% 96.1% 96.0% 95.8%
L12 36.09 5383.6 100.3% 100.0% 99.5% 98.8% 98.5% 98.2% 97.6% 97.1% 96.4% 96.1% 96.0% 95.8%
L13 36.27 5471.9 102.8% 100.0% 99.6% 98.9% 98.6% 98.2% 97.4% 96.9% 96.1% 96.1% 96.0% 95.8%
L14 36.00 5450.0 102.1% 100.0% 99.8% 99.0% 98.6% 98.2% 97.6% 97.1% 96.2% 96.0% 96.0% 95.8%
L15 36.33 5466.5 101.8% 100.0% 99.6% 98.9% 98.6% 98.1% 97.7% 96.9% 96.1% 96.1% 96.0% 95.8%
L16 36.21 5383.7 101.3% 100.0% 98.9% 98.8% 98.4% 98.2% 97.5% 96.9% 96.4% 96.1% 96.0% 95.8%
L17 36.24 5465.7 100.7% 100.0% 99.1% 99.0% 98.3% 98.1% 97.4% 97.2% 96.5% 96.1% 96.0% 95.8%
L18 36.27 5456.5 101.1% 100.0% 99.9% 99.1% 98.4% 98.2% 97.6% 97.0% 96.3% 96.1% 96.0% 95.8%
L19 36.35 5402.2 103.1% 100.0% 99.4% 99.0% 98.7% 98.2% 97.7% 96.8% 96.2% 96.1% 96.0% 95.8%
L20 36.23 5421.1 101.6% 100.0% 99.4% 98.9% 98.6% 97.9% 97.4% 97.2% 96.4% 96.1% 96.0% 95.8%
Avg. 36.21 5431.2 101.7% 100.0% 99.4% 98.9% 98.5% 98.1% 97.6% 97.0% 96.3% 96.1% 96.0% 95.8%
MIN 36.00 5340.4 100.0% 100.0% 98.9% 98.8% 98.3% 97.9% 97.4% 96.8% 96.1% 96.0% 95.8% 95.7%
MAX 36.38 5518.2 104.0% 100.0% 99.9% 99.1% 98.7% 98.3% 97.8% 97.2% 96.5% 96.1% 96.1% 95.8%
STDEV 0.1155 47.3 0.0105 0.0001 0.003 0.0009 0.0011 0.001 0.0012 0.0014 0.0013 0.0004 0.0006 0.0002
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Report No.: PCANL191211002-01
PC-EE-23-a
Page 11 of 17
4.2 Data Set 1: 55°C, 350 mA (Chromaticity Shift)
Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 54.1℃
Ambient Temperature: 53.2℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Chromaticity Shift (△ u’v’)
Sample No. u’ v’ CCT(K) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L1 0.2591 0.5309 2757 0.0005 0.0007 0.0006 0.0009 0.0013 0.0018 0.0022 0.0028 0.0035 0.0035 0.0036 0.0040
L2 0.2583 0.5309 2773 0.0004 0.0005 0.0008 0.0010 0.0012 0.0018 0.0023 0.0030 0.0036 0.0038 0.0038 0.0041
L3 0.2597 0.5306 2744 0.0003 0.0003 0.0006 0.0010 0.0014 0.0019 0.0024 0.0029 0.0034 0.0037 0.0036 0.0039
L4 0.2608 0.5318 2716 0.0004 0.0008 0.0005 0.0009 0.0011 0.0020 0.0022 0.0029 0.0035 0.0037 0.0037 0.0041
L5 0.2590 0.5307 2759 0.0006 0.0007 0.0009 0.0008 0.0015 0.0021 0.0024 0.0031 0.0036 0.0035 0.0036 0.0039
L6 0.2592 0.5300 2758 0.0007 0.0009 0.0006 0.0009 0.0014 0.0017 0.0023 0.0030 0.0035 0.0036 0.0037 0.0041
L7 0.2587 0.5303 2768 0.0009 0.0011 0.0011 0.0010 0.0014 0.0018 0.0025 0.0031 0.0036 0.0038 0.0038 0.0040
L8 0.2604 0.5312 2729 0.0005 0.0008 0.0007 0.0008 0.0013 0.0017 0.0023 0.0030 0.0035 0.0037 0.0037 0.0040
L9 0.2602 0.5307 2735 0.0007 0.0008 0.0005 0.0007 0.0015 0.0019 0.0022 0.0030 0.0036 0.0037 0.0037 0.0040
L10 0.2589 0.5312 2760 0.0005 0.0005 0.0007 0.0011 0.0014 0.0018 0.0024 0.0029 0.0035 0.0036 0.0037 0.0040
L11 0.2596 0.5309 2746 0.0008 0.0009 0.0010 0.0011 0.0013 0.0017 0.0023 0.0030 0.0036 0.0037 0.0037 0.0040
L12 0.2587 0.5309 2765 0.0004 0.0007 0.0009 0.0010 0.0012 0.0016 0.0022 0.0029 0.0036 0.0037 0.0037 0.0040
L13 0.2599 0.5319 2735 0.0007 0.0005 0.0008 0.0008 0.0014 0.0020 0.0022 0.0030 0.0036 0.0037 0.0037 0.0040
L14 0.2598 0.5315 2740 0.0005 0.0006 0.0008 0.0009 0.0015 0.0019 0.0024 0.0030 0.0036 0.0037 0.0037 0.0040
L15 0.2600 0.5316 2735 0.0008 0.0005 0.0007 0.0007 0.0016 0.0018 0.0026 0.0030 0.0036 0.0037 0.0037 0.0040
L16 0.2598 0.5313 2739 0.0003 0.0004 0.0004 0.0008 0.0014 0.0019 0.0023 0.0028 0.0035 0.0037 0.0037 0.0040
L17 0.2583 0.5313 2772 0.0002 0.0005 0.0004 0.0009 0.0015 0.0020 0.0026 0.0030 0.0036 0.0037 0.0037 0.0040
L18 0.2606 0.5313 2724 0.0006 0.0003 0.0007 0.0010 0.0014 0.0019 0.0023 0.0028 0.0037 0.0037 0.0037 0.0040
L19 0.2589 0.5313 2759 0.0004 0.0006 0.0006 0.0011 0.0016 0.0020 0.0023 0.0030 0.0037 0.0037 0.0037 0.0040
L20 0.2595 0.5315 2745 0.0005 0.0005 0.0008 0.0010 0.0014 0.0017 0.0026 0.0028 0.0035 0.0037 0.0037 0.0040
AV 0.2595 0.5311 2748 0.0005 0.0006 0.0007 0.0009 0.0014 0.0019 0.0023 0.0029 0.0036 0.0037 0.0037 0.0040
MIN 0.2583 0.5300 2716 0.0002 0.0003 0.0004 0.0007 0.0011 0.0016 0.0022 0.0028 0.0034 0.0035 0.0036 0.0039
MAX 0.2608 0.5319 2773 0.0009 0.0011 0.0011 0.0011 0.0016 0.0021 0.0026 0.0031 0.0037 0.0038 0.0038 0.0041
STDEV 0.0007 0.0005 16.3819 0.0002 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0000 0.0000
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Report No.: PCANL191211002-01
PC-EE-23-a
Page 12 of 17
4.3 Data Set 2: 85°C, 1440 mA (Lumen Maintenance)
Lumen Maintenance (%)
SampleNo. VF(V) Φ(lm) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L21 36.16 5475.4 100.4% 100.0% 99.7% 98.6% 98.2% 97.4% 96.8% 96.5% 95.7% 95.4% 95.2% 95.0%
L22 36.12 5398.3 100.6% 100.0% 99.4% 98.6% 98.1% 97.6% 97.1% 96.4% 95.5% 95.4% 95.0% 94.9%
L23 36.31 5403.8 101.2% 100.0% 99.7% 98.5% 98.0% 97.4% 97.1% 96.2% 95.4% 95.4% 95.0% 94.9%
L24 36.17 5474.6 101.4% 100.0% 99.5% 98.7% 98.1% 97.5% 96.9% 96.4% 95.6% 95.3% 95.1% 94.9%
L25 36.03 5334.2 101.2% 100.0% 99.3% 98.4% 98.2% 97.5% 96.9% 96.3% 95.8% 95.4% 95.1% 95.0%
L26 36.12 5405.9 100.7% 100.0% 99.1% 98.5% 98.1% 97.6% 96.7% 96.5% 95.4% 95.4% 95.0% 94.9%
L27 36.18 5378.0 100.2% 99.9% 99.0% 98.7% 98.1% 97.6% 96.8% 96.4% 95.7% 95.4% 95.0% 94.9%
L28 36.06 5438.5 100.6% 100.0% 99.5% 98.6% 98.3% 97.6% 97.0% 96.3% 95.7% 95.3% 95.1% 95.0%
L29 36.35 5462.1 102.7% 100.0% 98.9% 98.5% 98.1% 97.3% 96.8% 96.2% 95.4% 95.4% 95.0% 95.0%
L30 36.31 5428.4 102.7% 100.0% 98.7% 98.7% 98.0% 97.6% 97.1% 96.5% 95.7% 95.4% 95.0% 94.9%
L31 36.09 5436.9 102.1% 100.0% 99.3% 98.6% 98.2% 97.4% 97.0% 96.4% 95.8% 95.4% 95.1% 94.9%
L32 36.03 5370.5 101.5% 100.0% 99.3% 98.6% 98.2% 97.7% 96.8% 96.2% 95.7% 95.3% 95.1% 95.0%
L33 36.16 5338.4 101.0% 99.9% 98.5% 98.6% 98.3% 97.5% 97.0% 96.6% 95.7% 95.4% 95.0% 95.0%
L34 36.37 5390.1 101.4% 100.0% 98.8% 98.4% 98.1% 97.5% 96.8% 96.2% 95.6% 95.4% 95.1% 94.9%
L35 36.37 5387.8 100.5% 100.0% 98.7% 98.7% 98.1% 97.6% 96.9% 96.5% 95.4% 95.4% 95.1% 95.0%
L36 36.12 5432.1 101.1% 100.0% 99.1% 98.7% 98.3% 97.6% 97.0% 96.3% 95.7% 95.4% 95.1% 95.0%
L37 36.10 5372.4 101.7% 99.9% 98.4% 98.6% 98.1% 97.8% 96.8% 96.2% 95.4% 95.4% 95.1% 94.9%
L38 36.09 5370.2 100.7% 100.0% 98.3% 98.6% 98.1% 97.5% 96.9% 96.3% 95.8% 95.4% 95.1% 94.9%
L39 36.33 5391.6 100.6% 100.0% 98.6% 98.6% 98.2% 97.6% 96.7% 96.6% 95.5% 95.4% 95.1% 95.0%
L40 36.30 5369.1 101.5% 100.0% 98.6% 98.6% 98.3% 97.4% 96.7% 96.3% 95.8% 95.4% 95.1% 95.0%
Avg. 36.19 5402.9 101.2% 100.0% 99.0% 98.6% 98.2% 97.5% 96.9% 96.4% 95.6% 95.4% 95.1% 94.9%
MIN 36.03 5334.2 100.2% 99.9% 98.3% 98.4% 98.0% 97.3% 96.7% 96.2% 95.4% 95.3% 95.0% 94.9%
MAX 36.37 5475.4 102.7% 100.0% 99.7% 98.7% 98.3% 97.8% 97.1% 96.6% 95.8% 95.4% 95.2% 95.0%
STDEV 0.1179 41.1 0.0072 0.0002 0.0044 0.001 0.001 0.0012 0.0013 0.0013 0.0015 0.0002 0.0005 0.0003
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 83.9℃
Ambient Temperature: 83.1℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Report No.: PCANL191211002-01
PC-EE-23-a
Page 13 of 17
4.4 Data Set 2: 85°C,1440 mA (Chromaticity Shift)Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 83.9℃
Ambient Temperature: 83.1℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Chromaticity Shift (△ u’v’)
Sample No. u’ v’ CCT(K) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L21 0.2592 0.5313 2752 0.0006 0.0008 0.0008 0.0013 0.0019 0.0021 0.0028 0.0035 0.0039 0.0041 0.0040 0.0039
L22 0.2601 0.5316 2732 0.0007 0.0007 0.0009 0.0014 0.0020 0.0022 0.0030 0.0032 0.0037 0.0036 0.0043 0.0047
L23 0.2586 0.5303 2771 0.0005 0.0007 0.0009 0.0012 0.0021 0.0021 0.0028 0.0032 0.0039 0.0038 0.0040 0.0041
L24 0.2584 0.5306 2772 0.0004 0.0008 0.0011 0.0013 0.0019 0.0022 0.0030 0.0034 0.0038 0.0042 0.0042 0.0044
L25 0.2602 0.5322 2729 0.0009 0.0012 0.0012 0.0011 0.0021 0.0023 0.0027 0.0031 0.0036 0.0040 0.0039 0.0041
L26 0.2601 0.5321 2730 0.0006 0.0006 0.0009 0.0013 0.0021 0.0021 0.0027 0.0034 0.0038 0.0041 0.0040 0.0042
L27 0.2590 0.5310 2759 0.0009 0.0010 0.0012 0.0014 0.0018 0.0022 0.0028 0.0032 0.0037 0.0037 0.0042 0.0045
L28 0.2589 0.5313 2759 0.0007 0.0008 0.0009 0.0013 0.0017 0.0022 0.0028 0.0032 0.0038 0.0038 0.0042 0.0042
L29 0.2587 0.5307 2765 0.0009 0.0009 0.0011 0.0013 0.0018 0.0023 0.0029 0.0032 0.0036 0.0041 0.0041 0.0041
L30 0.2609 0.5319 2715 0.0005 0.0006 0.0006 0.0011 0.0018 0.0024 0.0029 0.0035 0.0039 0.0041 0.0040 0.0042
L31 0.2596 0.5295 2752 0.0010 0.0006 0.0008 0.0013 0.0017 0.0022 0.0027 0.0032 0.0038 0.0039 0.0042 0.0044
L32 0.2600 0.5310 2738 0.0006 0.0005 0.0007 0.0014 0.0018 0.0023 0.0028 0.0033 0.0037 0.0038 0.0042 0.0043
L33 0.2583 0.5301 2775 0.0009 0.0011 0.0011 0.0014 0.0017 0.0024 0.0030 0.0033 0.0040 0.0041 0.0041 0.0042
L34 0.2602 0.5298 2738 0.0007 0.0007 0.0009 0.0015 0.0018 0.0021 0.0029 0.0034 0.0038 0.0041 0.0040 0.0042
L35 0.2592 0.5307 2755 0.0009 0.0010 0.0013 0.0015 0.0019 0.0024 0.0029 0.0033 0.0037 0.0040 0.0041 0.0043
L36 0.2605 0.5316 2724 0.0008 0.0006 0.0008 0.0012 0.0019 0.0025 0.0028 0.0031 0.0037 0.0038 0.0042 0.0043
L37 0.2615 0.5321 2702 0.0005 0.0005 0.0007 0.0014 0.0020 0.0024 0.0029 0.0032 0.0037 0.0041 0.0042 0.0042
L38 0.2603 0.5318 2728 0.0004 0.0007 0.0009 0.0015 0.0019 0.0023 0.0028 0.0031 0.0038 0.0041 0.0041 0.0042
L39 0.2578 0.5304 2786 0.0007 0.0005 0.0007 0.0013 0.0020 0.0024 0.0028 0.0032 0.0040 0.0041 0.0041 0.0042
L40 0.2607 0.5315 2722 0.0008 0.0012 0.0013 0.0014 0.0021 0.0025 0.0029 0.0033 0.0038 0.0039 0.0041 0.0043
AV 0.2596 0.5311 2745 0.0007 0.0008 0.0009 0.0013 0.0019 0.0023 0.0029 0.0033 0.0038 0.0040 0.0041 0.0043
MIN 0.2578 0.5295 2702 0.0004 0.0005 0.0006 0.0011 0.0017 0.0021 0.0027 0.0031 0.0036 0.0036 0.0039 0.0039
MAX 0.2615 0.5322 2786 0.0010 0.0012 0.0013 0.0015 0.0021 0.0025 0.0030 0.0035 0.0040 0.0042 0.0043 0.0047
STDEV 0.0010 0.0008 22.6311 0.0002 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0002 0.0001 0.0002
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Report No.: PCANL191211002-01
PC-EE-23-a
Page 14 of 17
4.5 Data Set 3: 105°C, 1440 mA (Lumen Maintenance)
Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 104.3℃
Ambient Temperature: 103.5℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Lumen Maintenance (%)
SampleNo. VF(V) Φ(lm) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L41 36.30 5357.9 100.1% 99.9% 98.7% 98.3% 97.7% 97.2% 96.6% 95.9% 95.1% 95.1% 95.1% 94.3%
L42 36.06 5342.3 100.0% 100.0% 98.6% 98.2% 97.7% 97.1% 96.7% 96.0% 95.4% 95.2% 94.9% 94.8%
L43 36.24 5448.6 101.4% 99.9% 98.7% 98.4% 97.8% 96.9% 96.5% 96.2% 95.5% 95.2% 94.9% 94.9%
L44 36.20 5340.7 101.9% 100.0% 99.0% 98.3% 97.8% 97.4% 96.7% 96.0% 95.4% 95.0% 95.0% 94.3%
L45 36.04 5445.2 100.9% 99.9% 99.1% 98.3% 97.7% 97.6% 96.5% 96.1% 95.5% 95.1% 95.0% 94.6%
L46 36.28 5424.2 101.9% 100.0% 98.7% 98.3% 97.7% 97.1% 96.6% 96.3% 95.4% 95.2% 94.9% 94.9%
L47 36.40 5450.4 101.8% 100.0% 98.7% 98.2% 97.6% 97.3% 96.5% 95.9% 95.5% 95.1% 94.9% 94.9%
L48 36.01 5334.6 100.7% 100.0% 98.5% 98.1% 97.8% 97.3% 96.5% 96.0% 95.2% 95.0% 95.0% 94.5%
L49 36.23 5391.0 101.8% 99.9% 98.5% 98.4% 97.8% 96.9% 96.7% 96.2% 95.3% 95.2% 95.0% 94.9%
L50 36.14 5362.6 101.3% 99.9% 98.8% 98.3% 97.9% 97.2% 96.7% 95.9% 95.5% 95.1% 94.9% 94.9%
L51 36.01 5346.3 100.5% 100.0% 99.0% 98.1% 97.8% 97.2% 96.4% 96.2% 95.1% 95.0% 95.0% 94.8%
L52 36.07 5350.7 101.1% 99.9% 98.6% 98.3% 97.8% 97.2% 96.6% 96.0% 95.2% 95.1% 95.0% 94.7%
L53 36.14 5342.8 101.5% 100.0% 98.7% 98.0% 97.8% 97.0% 96.6% 96.0% 95.3% 95.1% 95.0% 94.9%
L54 36.08 5412.7 100.2% 100.0% 98.8% 98.3% 97.7% 97.2% 96.6% 96.0% 95.1% 95.1% 95.0% 94.9%
L55 36.36 5458.8 100.7% 100.0% 98.8% 98.4% 97.8% 97.4% 96.4% 95.9% 95.1% 95.1% 95.0% 94.7%
L56 36.37 5424.5 101.9% 100.0% 98.6% 98.3% 97.8% 97.3% 96.6% 96.2% 95.4% 95.1% 95.0% 94.7%
L57 36.02 5365.8 101.5% 99.9% 98.6% 98.3% 97.6% 97.1% 96.7% 96.2% 95.3% 95.1% 95.0% 94.9%
L58 36.27 5410.5 101.3% 100.0% 98.7% 98.2% 98.0% 97.2% 96.8% 96.2% 95.4% 95.1% 95.0% 94.8%
L59 36.28 5353.9 101.6% 100.0% 98.8% 98.3% 97.7% 97.2% 96.6% 96.3% 95.4% 95.1% 95.0% 94.7%
L60 36.40 5355.2 100.2% 100.0% 98.4% 98.3% 97.8% 97.2% 96.8% 96.0% 95.4% 95.1% 95.0% 94.7%
Avg. 36.20 5385.9 101.1% 100.0% 98.7% 98.3% 97.8% 97.2% 96.6% 96.1% 95.3% 95.1% 95.0% 94.7%
MIN 36.01 5334.6 100.0% 99.9% 98.4% 98.0% 97.6% 96.9% 96.4% 95.9% 95.1% 95.0% 94.9% 94.3%
MAX 36.40 5458.8 101.9% 100.0% 99.1% 98.4% 98.0% 97.6% 96.8% 96.3% 95.5% 95.2% 95.1% 94.9%
STDEV 0.1362 43.6 0.0065 0.0003 0.0018 0.0011 0.001 0.0016 0.0011 0.0014 0.0014 0.0005 0.0004 0.0019
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Report No.: PCANL191211002-01
PC-EE-23-a
Page 15 of 17
4.6 Data Set 3: 105°C,350 mA (Chromaticity Shift)
Description of Light Sources Tested: HRA1430-27-80-37-A000-F1
Case Temperature: 104.3℃
Ambient Temperature: 103.5℃
Drive Current: 1440mA
Measure Current: 1440mA
Failures Observed: None
Chromaticity Shift (△ u’v’)
Sample No. u’ v’ CCT(K) 1000
hrs2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
10000hrs
11000hrs
12000hrs
L41 0.2591 0.3533 2759 0.0009 0.0012 0.0013 0.0014 0.0021 0.0025 0.0030 0.0035 0.0044 0.0042 0.0046 0.0039
L42 0.2586 0.3534 2770 0.0006 0.0009 0.0011 0.0015 0.0020 0.0026 0.0032 0.0035 0.0041 0.0044 0.0045 0.0055
L43 0.2603 0.3541 2730 0.0008 0.0009 0.0008 0.0014 0.0021 0.0025 0.0032 0.0037 0.0045 0.0044 0.0043 0.0046
L44 0.2601 0.3538 2736 0.0007 0.0010 0.0011 0.0016 0.0022 0.0028 0.0030 0.0037 0.0041 0.0045 0.0046 0.0048
L45 0.2590 0.3541 2758 0.0008 0.0006 0.0009 0.0014 0.0020 0.0025 0.0031 0.0036 0.0041 0.0042 0.0045 0.0046
L46 0.2594 0.3539 2749 0.0009 0.0007 0.0010 0.0015 0.0022 0.0025 0.0030 0.0037 0.0044 0.0042 0.0046 0.0044
L47 0.2586 0.3539 2767 0.0009 0.0010 0.0013 0.0014 0.0021 0.0024 0.0031 0.0034 0.0042 0.0044 0.0043 0.0055
L48 0.2593 0.3545 2748 0.0007 0.0007 0.0012 0.0015 0.0022 0.0025 0.0032 0.0037 0.0041 0.0045 0.0044 0.0046
L49 0.2598 0.3543 2739 0.0008 0.0011 0.0007 0.0016 0.0021 0.0028 0.0032 0.0036 0.0040 0.0045 0.0046 0.0046
L50 0.2599 0.3544 2737 0.0008 0.0006 0.0011 0.0015 0.0020 0.0025 0.0032 0.0037 0.0042 0.0042 0.0045 0.0044
L51 0.2597 0.3542 2743 0.0008 0.0014 0.0015 0.0017 0.0021 0.0027 0.0033 0.0036 0.0041 0.0042 0.0044 0.0047
L52 0.2581 0.3541 2775 0.0007 0.0010 0.0013 0.0015 0.0022 0.0025 0.0032 0.0034 0.0045 0.0045 0.0044 0.0053
L53 0.2604 0.3542 2727 0.0010 0.0010 0.0012 0.0016 0.0023 0.0026 0.0032 0.0035 0.0042 0.0045 0.0046 0.0046
L54 0.2588 0.3542 2761 0.0007 0.0009 0.0009 0.0014 0.0020 0.0025 0.0029 0.0034 0.0045 0.0043 0.0045 0.0046
L55 0.2595 0.3542 2746 0.0008 0.0011 0.0014 0.0018 0.0021 0.0027 0.0031 0.0034 0.0044 0.0042 0.0044 0.0045
L56 0.2586 0.3542 2766 0.0008 0.0013 0.0010 0.0014 0.0024 0.0025 0.0031 0.0035 0.0043 0.0043 0.0044 0.0053
L57 0.2598 0.3544 2739 0.0010 0.0007 0.0012 0.0016 0.0020 0.0026 0.0030 0.0035 0.0042 0.0045 0.0045 0.0049
L58 0.2584 0.3534 2774 0.0007 0.0009 0.0013 0.0016 0.0021 0.0026 0.0030 0.0034 0.0043 0.0043 0.0046 0.0046
L59 0.2583 0.3537 2774 0.0009 0.0006 0.0010 0.0014 0.0022 0.0025 0.0030 0.0037 0.0044 0.0042 0.0045 0.0045
L60 0.2601 0.3548 2730 0.0007 0.0007 0.0009 0.0014 0.0022 0.0027 0.0030 0.0036 0.0040 0.0043 0.0044 0.0047
AV 0.2593 0.3541 2751 0.0008 0.0009 0.0011 0.0015 0.0021 0.0026 0.0031 0.0036 0.0043 0.0043 0.0045 0.0047
MIN 0.2581 0.3533 2727 0.0006 0.0006 0.0007 0.0014 0.0020 0.0024 0.0029 0.0034 0.0040 0.0042 0.0043 0.0039
MAX 0.2604 0.3548 2775 0.0010 0.0014 0.0015 0.0018 0.0024 0.0028 0.0033 0.0037 0.0045 0.0045 0.0046 0.0055
STDEV 0.0007 0.0004 16.1487 0.0001 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0002 0.0001 0.0001 0.0004
N 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20