9500 mpr o _26 m
TRANSCRIPT
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 1/314
9500 MPROperation and Administration
PN 3EM23954AB 01
R01.02, Issue 01, February 2010
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 2/314
© Alcatel-Lucent 2010 - All Rights ReservedPrinted in U.S.A.
THIS PRODUCT COMPLIES WITH D.H.H.S. RADIATION PERFORMANCE STANDARDS 21
CFR, 1040.10, FOR A CLASS 1 LASER PRODUCT.
DANGER
Invisible laser radiation is present when the optic connector is open. AVOID DIRECT
EXPOSURE TO BEAM.
WARNING
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case users will be required to correct the
interference at their own expense.
NOTICE
This manual applies to 9500 MPR R01.02 software. Release notes describing revisions to this software may
impact operations described in this manual.
This transfer of commodities, technology, or software, if from the United States, is an export in accordance
with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited. The export or
re-export (further transfer) of such commodities, technology, software or products made from such
technology is prohibited without proper authorization(s) from the U.S. Department of Commerce or other
appropriate U.S. government agency(s).
All rights reserved. No part of this manual may be reproduced, translated, stored in a retrieval system, or
transmitted or distributed by any means, electronic or mechanical, by photocopying, recording, or otherwise,
without the written permission of Alcatel-Lucent. Preparing derivative works or providing instruction basedon the material is prohibited unless agreed to in writing by Alcatel-Lucent.
The product specification and/or performance levels contained in this document are for information
purposes only and are subject to change without notice. They do not represent any obligation on the part of
Alcatel-Lucent. Such obligations will only be committed to in a written sales agreement signed by
Alcatel-Lucent.
DOCUMENTATION
Product documentation is available on Alcatel-Lucent’s OnLine Customer Support web site at
https://support.lucent.com/portal/olcsHome.do.
To offer comments on this documentation, visit Alcatel-Lucent’s OnLine Customer Support web site at
https://support.lucent.com/portal/olcsHome.do and select Contact us, Customer support , and then OnLine
Assistance or write to the following address.
Alcatel-Lucent
Attention: Doc Comment, M/S RND-1
3400 W. Plano Pkwy.
Plano, Texas 75075-0811 USA
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 3/314
3EM23954ABIssue 01, February 2010
© Alcatel-Lucent 2010 - All Rights Reserved i
ALCATEL-LUCENT PRACTICEStandard
9500 MPR Operation and AdministrationTable of Contents
Introduction
1. OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Writing Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Admonishments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Document Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2. PRODUCT SUPPORT INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Telephone Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Product Documentation and Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Technical Support Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Repair and Return Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Spare Parts and Replacement Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Service Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Installation and Maintenance Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Index Task Lists (IXLs)
IXL-100 Index Task List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
IXL-101 User Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
IXL-102 Equipment Provisioning and Deprovisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
IXL-103 System Information Reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
IXL-104 System Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
IXL-105 Equipment Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Non-trouble Procedures (NTPs)
NTP-100 DS1 Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
NTP-101 DS3 Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
NTP-102 Ethernet Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
NTP-103 DS1 Deprovisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
NTP-104 DS3 Deprovisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 4/314
3EM23954ABIssue 01, February 2010
Table of Contentsii
NTP-105 Ethernet Deprovisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Detailed Level Procedures (DLPs)
DLP-100 Log Into and Out of System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
DLP-101 Administer User Profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
DLP-102 Configure PC Network Card to Connect to NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
DLP-103 Change Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
DLP-104 Enable Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
DLP-105 Disable Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
DLP-106 Provision Equipment Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
DLP-107 Deprovision Equipment Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
DLP-108 Provision Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-81
DLP-109 Provision Radio Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-87
DLP-110 Provision Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-93
DLP-112 Provision Cross Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-99
DLP-113 View Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-115
DLP-114 View Abnormal Condition List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-119
DLP-115 View Protection Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-121
DLP-116 Download Provisioning Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-129
DLP-117 Administer System Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-135
DLP-118 Administer Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-143
DLP-119 Administer System Date and Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-153
DLP-120 Administer Software License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-159
DLP-121 Perform Protection Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-163
DLP-122 Performance Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-179
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 5/314
3EM23954ABIssue 01, February 2010
Table of Contents iii
DLP-123 Perform Radio Power Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-195
DLP-126 Deprovision Cross Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-199
DLP-127 Deprovision Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-205
DLP-128 Administer NE Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-211
DLP-129 View Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-223
DLP-130 IF Cable Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-227
DLP-131 MIB Database Management (Backup and Restore) . . . . . . . . . . . . . . . . . . . . . . . . . 4-239
DLP-132 Load System and Craft Terminal Software on PC . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-247
WebEML Craft Terminal Reference Guide
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Main Screen Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 6/314
3EM23954ABIssue 01, February 2010
Table of Contentsiv
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 7/314
3EM23954ABIssue 01, February 2010
List of Figures v
9500 MPR Operation and AdministrationList of Figures
Figure 100-1. MPR-A R01.02 WebEML Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Figure 100-2. NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Figure 100-3. NETO Login Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Figure 100-4. JUSM/CT 9500MPR-A Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Figure 100-5. JUSM/CT 9500MPR-A Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Figure 100-6. NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Figure 101-1. User Management Drop-Down Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Figure 101-2. Profile Management Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Figure 101-3. Create User Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Figure 101-4. Profile Management Window - with Added User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Figure 101-5. User Management Drop-Down Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Figure 101-6. Profile Management Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Figure 101-7. Delete User Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Figure 101-8. Profile Management Window - with User Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Figure 101-9. User Management Drop-Down Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Figure 101-10.Profile Management Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Figure 101-11.Change User Password Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Figure 102-1. Internet Protocol (TCP/IP) Properties Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Figure 102-2. Internet Protocol (TCP/IP) Properties Window Configured for DHCP . . . . . . . . . . . . . 4-17
Figure 102-3. Internet Protocol (TCP/IP) Properties Window Configured to Use a specificIP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Figure 102-4. Run Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Figure 102-5. DOS Command Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 8/314
3EM23954ABIssue 01, February 2010
List of Figuresvi
Figure 102-6. Successful Ping Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Figure 103-1. User Change Password Drop-Down Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Figure 103-2. Changing Password Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Figure 104-1. Select Slot 2 to Enable Protect CSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
Figure 104-2. Select Protect CSM Equipment Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
Figure 104-3. Protect CSM Enabled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
Figure 104-4. Select Slot 9 to Enable FAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27
Figure 104-5. Select FAN Equipment Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
Figure 104-6. FAN Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
Figure 104-7. Select Slot to Enable MOD300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
Figure 104-8. Select MD300 Equipment Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
Figure 104-9. MOD300 Enabled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
Figure 104-10.Select Slot to Enable P32E1DS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
Figure 104-11.Select P32EDS1 Equipment Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
Figure 104-12.P32E1DS1 Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Figure 104-13.Select Slot to Enable P2E3DS3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
Figure 104-14.Select P2E3DS3 Equipment Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
Figure 104-15.P2E3DS3 Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
Figure 105-1. Enabled Spare CSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
Figure 105-2. Disable Protect CSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
Figure 105-3. Protect CSM Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
Figure 105-4. Enabled FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-43
Figure 105-5. Disable FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
Figure 105-6. FAN Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 9/314
3EM23954ABIssue 01, February 2010
List of Figures vii
Figure 105-7. Enabled MOD300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
Figure 105-8. Disable MOD300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
Figure 105-9. MOD300 Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48
Figure 105-10.Enabled P32E1DS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
Figure 105-11.Disable P32E1DS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
Figure 105-12.Disabled P32E1DS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
Figure 105-13.Enabled P2E3DS3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
Figure 105-14.Disable P2E3DS3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
Figure 105-15.Disabled P2E3DS3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
Figure 106-1. Resource List Area: CSM SFP Slot Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-56
Figure 106-2. Provision CSM SFP Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57
Figure 106-3. Provisioned CSM SFP Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-58
Figure 106-4. Resource List Area: P32E1DS1 Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-59
Figure 106-5. Provision P32E1DS1 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
Figure 106-6. Provisioned P32E1DS1 TDM2TDM Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-61
Figure 106-7. Provision P32E1DS1 for TDM2ETH Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
Figure 106-8. Provisioned P32E1DS1 TDM2ETH Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-63
Figure 106-9. Resource List Area: P2E3DS3 Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-64
Figure 106-10.Provision P2E3DS3 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-65
Figure 106-11.Provisioned P2E3DS3 TDM2TDM Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
Figure 106-12.Provision P2E3DS3 for TDM2ETH Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-67
Figure 106-13.Provisioned P2E3DS3 TDM2ETH Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
Figure 107-1. Resource List Area: CSM SFP Slot Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-70
Figure 107-2. Provisioned CSM SFP Port #5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-71
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 10/314
3EM23954ABIssue 01, February 2010
List of Figuresviii
Figure 107-3. Deprovisioned CSM SFP Port#5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72
Figure 107-4. Resource List Area: P32E1DS1 Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-73
Figure 107-5. Provisioned P32E1DS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74
Figure 107-6. Deprovision P32E1DS Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-75
Figure 107-7. Deprovisioned P32E1DS1 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-76
Figure 107-8. Resource List Area: P2E3DS3 Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-77
Figure 107-9. Provisioned P2E3DS3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-78
Figure 107-10.Deprovision P2E3DS3 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-79
Figure 107-11.Deprovisioned P2E3DS3 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-80
Figure 108-1. 9500 MPR Equipment Tab: CSM Card Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-82
Figure 108-2. CSM Ethernet Physical Interface: Settings Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-83
Figure 108-3. 9500 MPR Equipment Tab: CSM Card Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-84
Figure 108-4. CSM Ethernet Physical Interface: SFP Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85
Figure 109-1. MOD300 Direction and Channel Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-87
Figure 109-2. Provision Radio Channel Fixed Modulation Parameters . . . . . . . . . . . . . . . . . . . . . . . 4-88
Figure 109-3. Provision Radio Channel Adaptive Modulation Parameters . . . . . . . . . . . . . . . . . . . . 4-90
Figure 109-4. MOD300 Radio Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-91
Figure 109-5. MOD300 Radio Protection Provisioned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-92
Figure 110-1. Synchronization Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-93
Figure 110-2. Synchronization - Master / Revertive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-95
Figure 110-3. Synchronization - Slave / Revertive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-97
Figure 112-1. Ranging Sequential Flow IDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-102
Figure 112-2. Ranging Non-Sequential Flow IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-102
Figure 112-3. Cross Connection: Line Color Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-105
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 11/314
3EM23954ABIssue 01, February 2010
List of Figures ix
Figure 112-4. Configuration Cross Connection Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-106
Figure 112-5. PDH-RADIO Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-108
Figure 112-6. PDH to Ethernet Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-110
Figure 112-7. Ethernet to Radio Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-111
Figure 112-8. Radio to Radio Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-113
Figure 113-1. View NE Alarms Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-116
Figure 113-2. Alarm Monitor Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-116
Figure 113-3. Alarm Manager: Current Alarms Major Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-117
Figure 114-1. Abnormal Condition List Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-119
Figure 114-2. Abnormal Condition List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-120
Figure 115-1. Protection Schemes Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-121
Figure 115-2. Protection Schemes Resource Tree Expanded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-122
Figure 115-3. CSM Protection Scheme Parameter Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-123
Figure 115-4. Synchronization Protection Scheme Parameter Tab . . . . . . . . . . . . . . . . . . . . . . . . . 4-124
Figure 115-5. Radio Channel Protection Scheme Parameter Tab . . . . . . . . . . . . . . . . . . . . . . . . . . 4-125
Figure 115-6. Equipment Protection Scheme Parameter Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-126
Figure 115-7. HSB Protection Scheme Parameter Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-127
Figure 115-8. Rx Radio Protection Scheme Parameter Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-128
Figure 116-1. Diagnosis / Current Configuration View Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-129
Figure 116-2. Diagnosis / Current Configuration View Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-130
Figure 116-3. Provision Verification: Web Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-131
Figure 116-4. Provision Verification: Login Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-131
Figure 116-5. 9500MPR Web Server Main Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-132
Figure 116-6. Configuration Info File Download Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-133
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 12/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 13/314
3EM23954ABIssue 01, February 2010
List of Figures xi
Figure 121-7. Lockout Equipment Switch: Lockout Switch to Spare . . . . . . . . . . . . . . . . . . . . . . . . 4-170
Figure 121-8. Forced HSB Switch Main Radio Channel to Spare Radio Channel . . . . . . . . . . . . . . 4-171
Figure 121-9. Manual HSB Switch: Main Radio Channel to Spare Radio Channel . . . . . . . . . . . . . 4-172
Figure 121-10.Manual HSB Switch: Spare Radio Channel to Main Radio Channel . . . . . . . . . . . . . 4-173
Figure 121-11.Lockout HSB Switch: Lockout Spare Radio Channel. . . . . . . . . . . . . . . . . . . . . . . . . 4-174
Figure 121-12.Forced Rx Radio Switch: Main Radio Channel to Spare Radio Channel. . . . . . . . . .4-175
Figure 121-13.Manual Rx Radio Switch: Main Radio Channel to Spare Radio Channel . . . . . . . . . 4-176
Figure 121-14.Manual Rx Radio Switch: Spare Radio Channel to Main Radio Channel . . . . . . . . . 4-177
Figure 121-15.Lockout Rx Radio Switch Spare Radio Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-178
Figure 122-1. 9500 MPR Equipment Tab: MOD300 Card Selected. . . . . . . . . . . . . . . . . . . . . . . . . 4-181
Figure 122-2. Performance Monitoring Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-182
Figure 122-3. Threshold Data Creation Pane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-183
Figure 122-4. Threshold #2 Data Table Created . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-184
Figure 122-5. Threshold Data Table Selected for Modification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-185
Figure 122-6. Threshold Data Table Modified . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-186
Figure 122-7. Threshold Data Table Selected for Deletion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-187
Figure 122-8. Threshold Data Table Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-188
Figure 122-9. PM HOP - Channel #0 Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-189
Figure 122-10.PM HOP-Channel #0 Current Data 15 Minute Selected . . . . . . . . . . . . . . . . . . . . . . 4-190
Figure 122-11.PM Data HOP-Channel #0 Current Data 15 Minute Selected . . . . . . . . . . . . . . . . . . 4-191
Figure 122-12.PM Data HOP-Channel #1 History Data 15 Minute Selected . . . . . . . . . . . . . . . . . . 4-192
Figure 122-13.PM Data HOP-Channel #1 History Data 15 Minute Selected . . . . . . . . . . . . . . . . . . 4-193
Figure 123-1. Main Equipment Window: MOD300 Card Highlighted . . . . . . . . . . . . . . . . . . . . . . . . 4-195
Figure 123-2. Radio Power Measurement Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-196
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 14/314
3EM23954ABIssue 01, February 2010
List of Figuresxii
Figure 123-3. Radio Power Measurement: Graphical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-197
Figure 123-4. Radio Power Measurement: Tabular View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-198
Figure 126-1. Cross Connection Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-199
Figure 126-2. PDH-RADIO Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-200
Figure 126-3. PDH to Ethernet Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-201
Figure 126-4. Ethernet to Radio Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-202
Figure 126-5. Radio to Radio Cross Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-203
Figure 127-1. 9500 MPR Equipment Tab: CSM Card Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-206
Figure 127-2. CSM Ethernet Physical Interface: Settings Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-207
Figure 127-3. 9500 MPR Equipment Tab: CSM Card Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-208
Figure 127-4. CSM Ethernet Physical Interface: SFP Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . 4-209
Figure 128-1. NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-212
Figure 128-2. Network Elements List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-212
Figure 128-3. NE List Save Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-213
Figure 128-4. Network Elements List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-214
Figure 128-5. Network Elements List Window: Current NE Added . . . . . . . . . . . . . . . . . . . . . . . . . 4-215
Figure 128-6. Network Elements List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-216
Figure 128-7. NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-217
Figure 128-8. Open Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-217
Figure 128-9. Network ElemenT List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-218
Figure 128-10.NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-218
Figure 128-11.JUSM/CT 9500MPR-A Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-219
Figure 128-12.NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-220
Figure 128-13.Network ElemenT List Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-220
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 15/314
3EM23954ABIssue 01, February 2010
List of Figures xiii
Figure 128-14.NETO Overview Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-221
Figure 128-15.JUSM/CT 9500MPR-A Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-222
Figure 129-1. Event Log Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-223
Figure 129-2. Event Log Browser Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-224
Figure 130-1. IF Cable Loopback Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-227
Figure 130-2. Main Equipment Window: MOD300 Card Highlighted . . . . . . . . . . . . . . . . . . . . . . . . 4-228
Figure 130-3. Radio Channel Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-229
Figure 130-4. Transmitter TxMute Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-230
Figure 130-5. MOD300 IF Cable Loopback Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-231
Figure 130-6. MOD300 IF Cable Loopback Provisioned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-232
Figure 130-7. MOD300 IF Cable Loopback Active. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-233
Figure 130-8. MOD300 IF Cable Loopback Active. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-234
Figure 130-9. MOD300 IF Cable Loopback Active, Not Active Selected . . . . . . . . . . . . . . . . . . . . . 4-235
Figure 130-10.MOD300 IF Cable Loopback Deactivated (Not Active) . . . . . . . . . . . . . . . . . . . . . . . 4-236
Figure 130-11.Settings Tab, Transmitter TxMute Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-237
Figure 130-12.TxMute Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-238
Figure 131-1. Backup MIB Management Database Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-241
Figure 131-2. Backup MIB Management Database Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-241
Figure 131-3. Restore MIB Management Database Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-242
Figure 131-4. Restore MIB Management Database Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-243
Figure 131-5. Activate MIB Management Database Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-244
Figure 1-1. WebEML Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Figure 1-2. Main Menu Bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Figure 1-3. Main Tool Bar Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 16/314
3EM23954ABIssue 01, February 2010
List of Figuresxiv
Figure 1-4. Resource Tree Area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Figure 1-5. Resource List Area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Figure 1-6. Resource Detail Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Figure 1-7. Severity Alarm Synthesis Area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Figure 1-8. Severity Alarm Synthesis Area: Alarm Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Figure 1-9. Domain Alarm Synthesis Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Figure 1-10. Domain Alarm Synthesis Area: Alarm Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Figure 1-11. Status Control Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 17/314
3EM23954ABIssue 01, February 2010
List of Tables xv
9500 MPR Operation and AdministrationList of Tables
Table 100-A. Index Task List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Table 101-A. Common User Administration Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Table 102-A. Equipment Provisioning and Deprovisioning Functions. . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Table 103-A. System Information Reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Table 104-A. System Administration Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Table 105-A. Auxiliary Equipment Provisioning Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Table 100-A. Default User Account Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Table 101-A. Default User Account Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Table 112-A. Range of Flow ID’s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-101
Table 117-A. DSCP Traffic Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-136
Table 122-A. Default TCA Threshold Alarm Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-180
Table 1-A. Status Control Color Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 18/314
3EM23954ABIssue 01, February 2010
List of Tablesxvi
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 19/314
3EM23954ABIssue 01, February 2010
Introduction 1-1
Introduction
1. OVERVIEW
1.1 This user's guide provides step-by-step procedures to help users
perform tasks. Each procedure contains important introductory information
that is essential to understanding and completing the task properly.
Procedures must be started at step 1, and steps must be performed in the order
given. Failure to do so may cause unforeseen hazardous conditions.
Writing Conventions
1.2 Boldface characters indicate commands or parameters that must be
entered or keys that must be pressed. Enter input parameters exactly as shown
in the examples.
Admonishments
1.3 To avoid hazardous conditions, observe the following admonishments:
DANGER Possibility of personal injury.
CAUTION Possibility of service interruption.
WARNING Possibility of equipment damage.
Related Documentation
1.4 For additional system information, refer to the following related
documents:
•
9500 MPR Product Information (PN 3EM23952AB)
• 9500 MPR Installation Practices manual (PN 3EM23953AB)
• 9500 MPR Turn-Up manual (PN 3EM23955AB)
• 9500 MPR Maintenance and Trouble Clearing manual
(PN 3EM23956AB)
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 20/314
3EM23954ABIssue 01, February 2010
Introduction1-2
Document Types
1.5 The documentation contains all instructions needed to perform a task.
This manual consists of the following types of documents:
• Task Index List (IXL)
• Nontrouble Procedure (NTP)
• Detailed Level Procedure (DLP)
Task Index List (IXL)
1.6 IXLs group procedures by function. Each IXL lists procedures
alphabetically by name and refers the user to the appropriate procedure
number.
Nontrouble Procedure (NTP)
1.7 NTPs list the major steps required to complete a task. This list may be
all an experienced user requires. For an inexperienced user, each step refers to
a DLP. The steps must be performed in the order listed.
Detailed Level Procedure (DLP)
1.8 DLPs contain detailed steps and supporting information required tocomplete a task. When a DLP is referenced from another part of the manual,
perform the DLP, then return to the point where the DLP was referenced.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 21/314
3EM23954ABIssue 01, February 2010
Introduction 1-3
2. PRODUCT SUPPORT INFORMATION
Telephone Support
Customer Service Telephone Support
2.1 For telephone support for the customer services mentioned in this
Product Support Information, call the Alcatel-Lucent's customer Technical
Support Center at 1-(888) 252-2832 for details, 8:00 a.m. to 5:00 p.m., Central
Time, Monday through Friday. Ask the operator for the appropriate service to
be connected to a qualified representative or engineer.
2.2 After-hours emergency telephone support is also available by calling
the Alcatel-Lucent's customer Technical Support Center at 1-(888) 252-2832. An emergency is defined as an out-of-service, traffic-affecting problem or a
nonoperating alarm system on traffic-bearing systems.
Product Documentation and Training
Product Documentation
2.3 Product documentation is available on both paper and CD-ROM. The
documentation can also be accessed through Alcatel-Lucent’s OnLine
Customer Support web site at:
https://support.alcatel-lucent.com/portal/olcsHome.do
Product documentation updates appear on Alcatel-Lucent’s OnLine Customer
Support web site before they are available in any other format.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 22/314
3EM23954ABIssue 01, February 2010
Introduction1-4
2.4 At Alcatel-Lucent’s OnLine Customer Support web site, follow the on-
screen instructions to register for access and obtain a login ID. In addition to
accessing product documentation, the Alcatel-Lucent’s OnLine Customer
Support web site allows the user to view the following:
• Application notes
• Configuration notes
• Data collections
• Frequently Asked Questions (FAQs)
• General information books
• General Release Documents (GRDs)
• Installation documents
• Methods of Procedure (MOPs)
• Product Change Notifications (PCNs)
• Product Information Bulletins (PIBs)
• Product manual updates
• Software patch and software load documents
• Software Update Documents (SUDs)
• Technical bulletins
• Training documents
• Urgent Product Warnings (UPWs)
Training
2.5 Equipment training is available to all customers. Crafts and
maintenance personnel who are trained by Alcatel-Lucent's Training
department can expect more effective assistance if they need to call theTechnical Assistance Center. Regularly scheduled courses are available at the
training facilities in Plano, Texas. If a customer cannot attend a standard
course, the Training department can arrange a course for a specific
requirement and conduct it at the customer's facility. For further information,
call customer service telephone support and ask for a training coordinator or
write to one of the following addresses:
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 23/314
3EM23954ABIssue 01, February 2010
Introduction 1-5
2.6 The annual Product Training Catalog can be ordered by calling the
training coordinator, or it can be viewed on-line at:
http://www1.alcatel-lucent.com/us/product_training/catalog
Technical Support Center
2.7 The Technical Support Center (TSC) staff is always ready to provide
high-quality technical assistance. Customers can expect effective telephoneassistance when their crafts and maintenance personnel have been trained by
Alcatel-Lucent's Training department and are equipped with adequate test
equipment, spares, and documentation at the site.
2.8 For technical assistance, call Alcatel-Lucent's customer Technical
Support Center at 1-(888) 252-2832.
After-hours Emergency Telephone Support
2.9 Emergency support is available after-hours for emergencies by calling
1-(888) 252-2832.
2.10 An emergency is defined as an out-of-service, traffic-affecting problem
or a nonoperating alarm system on traffic-bearing systems.
2.11 Nonemergency is defined as installation turn-ups, application
questions, traffic cutover, routine maintenance, or other non-service-affecting
maintenance. All non-service-affecting, after-hours telephone services are
billable to the customer.
2.12 Please provide the operator with the following information:
• Company name
• Caller name
• A telephone number where caller can be reached
• A brief description of the problem, including the product involved
IN USA: IN CANADA:
Alcatel-Lucent USA
3400 W. Plano Pkwy.
Plano, Texas 75075
ATTN: Training M/S 1206-553
Alcatel-Lucent Canada
Network Services Division
P.O. Box 13600
Ottawa, Ontario K2K 2E6
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 24/314
3EM23954ABIssue 01, February 2010
Introduction1-6
After-hours Nonemergency Telephone Support
2.13 After-hours telephone support to address new installations, system
expansions, system operations, system application, or other
non-service-affecting issues is available by contacting Alcatel-Lucent at1-(888) 252-2832.
On-site Technical Support
2.14 On-site technical support is available when an issue cannot be
resolved remotely. This determination is usually made by Alcatel-Lucent TSC
during the problem investigation process. These services may or may not be
billable to a customer. This depends on several factors such as what type of
Service Level Agreement a customer has with Alcatel-Lucent, the age of the
product, etc.
Repair and Return Services
2.15 As part of a comprehensive technical support program, Alcatel-Lucent
provides factory repair services for equipment. This service is available both
during and after the warranty period through Alcatel-Lucent's Return and
Repair department.
Spare Parts and Replacement Cards
2.16 For spare parts, spare cards, card exchange, and in-warranty
replacement on a routine or emergency basis, call customer service telephone
support.
2.17 Provide the following information:
• Customer Contact Name
• Customer Company Name
• Customer telephone number
• Customer E-mail Address
• A brief description of the problem, including product line, part
number, and quantity of parts needed
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 25/314
3EM23954ABIssue 01, February 2010
Introduction 1-7
2.18 For emergency assistance after normal business hours, call customer
service telephone support, ask the operator for Emergency Parts Assistance,
and provide the operator with the required information. The operator will
contact an appropriate individual to respond.
Return for Credit or Warranty Exchange Procedure
2.19 Returned equipment must have a Parts Request (PR) number. Obtain
an PR number by calling the Alcatel-Lucent Welcome Center at
1-866-582-3688.
2.20 No equipment should be returned without an PR number. The
following information is required:
• Description and quantity of equipment to be returned
• Reason for return
• Order number the equipment was purchased against and approximate
date of purchase
Service Center
2.21 The Service Center tests, repairs, and modifies all cards (both in and
out of warranty). Cards received for repair or modification are returned
promptly.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 26/314
3EM23954ABIssue 01, February 2010
Introduction1-8
Return for Repair Procedure
2.22 Refer to paragraph 2.19 for information on obtaining an PR number.
Notification to the Service Center and issuance of an PR number by
Alcatel-Lucent personnel must be made prior to shipment of parts. Thefollowing information must be furnished with the request for return
authorization:
• Purchase order number or requisition number
• Description and quantity of equipment to be returned
• Reason for return:
– Modification required
– Defective equipment to be repaired
• Warranty status (in or out of warranty) and warranty date stamped on
unit
• Specific nature of problem
• Name and telephone number of person who identified problem
• Special instruction/information
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 27/314
3EM23954ABIssue 01, February 2010
Introduction 1-9
Shipping Instructions for Repair, Credit, or
Warranty Exchange
2.23 Return equipment or parts prepaid to the address provided below. The
PR number must be prominently marked on the shipping label, the packinglist, and any correspondence regarding the order.
• Include company name, address, and name of person to contact in case
of a question.
• Include specific reason for return. (This aids prompt processing.)
• Include the same requisition number or purchase order number that
was furnished with request for return authorization.
• Include type number and part number of unit.
• State whether equipment is in or out of warranty.
• Furnish shipping address for return of unit, if applicable, or other
pertinent details.
• Mail purchase order, if applicable, to address shown under Return for
Repair Procedure, Attention: Service Center.
Installation and Maintenance Services
Engineering and Installation Service
2.24 Whether installation for specific equipment or a full turnkey networkfacility is needed, Installation Service can help. Alcatel-Lucent has experience
in central office, outside plant, and customer premises applications, and
specializes in flexible scheduling and high-quality service. Qualified staff are
in place nationwide, so an installation can be started and completed promptly.
Alcatel Lucent Return Equipment
Address
Alcatel Lucent c/o UPS-SCS Attn: Repair FE
2240 Outer Loop
Bldg 5 Door 505
Louisville, Ky 40219
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 28/314
3EM23954ABIssue 01, February 2010
Introduction1-10
Contract Maintenance Service
2.25 Field service from Alcatel-Lucent US and Canada offices are available.
Alcatel-Lucent field service is well-suited for private networks of any size.
2.26 Factory-trained service technicians are qualified on similar systems
before they are allowed to maintain customer equipment. They have direct
access to additional technical support around the clock and to all necessary
tools and test equipment.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 29/314
3EM23954ABIssue 01, February 2010
Index Task List 2-1
IXL-100
IndexTask Lists(IXLs)
IXL-100
Index Task List
Refer to table 100-A to select the type of procedure or information needed to perform tasks on the
system.
Table 100-A. Index Task List
TYPE OF PROCEDURE/INFORMATION REFERENCE
Equipment Functions IXL-105
Equipment Provisioning and Deprovisioning IXL-102
System Administration IXL-104
System Information Reports IXL-103
User Administration IXL-101
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 30/314
3EM23954ABIssue 01, February 2010
Index Task List2-2
IXL-100
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 31/314
3EM23954ABIssue 01, February 2010
User Administration 2-3
IXL-101
IXL-101
User Administration
Refer to table 101-A to identify a common user administration function and the corresponding
procedure.
Table 101-A. Common User Administration Functions
FUNCTION REFERENCE
Add New User DLP-101
Administer NE Lists DLP-128
Add NE to List DLP-128
Change a User’s Password DLP-101
Change Password DLP-103
Configure PC Network Card to Connect to NE DLP-102Configure Windows Firewall DLP-132
Create NE List DLP-128
Delete User DLP-101
Install/Upgrade JAVA JRE Software DLP-132
Install WebEML (JUSM/CT) Software DLP-132
Log Into System DLP-100
Log into NE From NE List DLP-128
Log Out of System DLP-100
Verify JAVA JRE Software Version DLP-132
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 32/314
3EM23954ABIssue 01, February 2010
User Administration2-4
IXL-101
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 33/314
3EM23954ABIssue 01, February 2010
Equipment Provisioning and Deprovisioning 2-5
IXL-102
IXL-102
Equipment Provisioning and Deprovisioning
Refer to table 102-A to identify an equipment provisioning or deprovisioning function and the
corresponding procedure.
Table 102-A. Equipment Provisioning and Deprovisioning Functions
FUNCTION REFERENCE
Deprovision Cross Connections DLP-126
Deprovision Ethernet Ports DLP-127
Deprovision Equipment Ports DLP-107
Disable Equipment DLP-105
Enable Equipment DLP-104
Provision Cross Connections DLP-112Provision Ethernet Ports DLP-108
Provision Equipment Ports DLP-106
Provision Radio Parameters DLP-109
Provision Synchronization DLP-110
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 34/314
3EM23954ABIssue 01, February 2010
Equipment Provisioning and Deprovisioning2-6
IXL-102
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 35/314
3EM23954ABIssue 01, February 2010
System Information Reports 2-7
IXL-103
IXL-103
System Information Reports
Refer to table 103-A to identify a system information report and the corresponding procedure for
retrieval of the report.
Table 103-A. System Information Reports
REPORT REFERENCE
View Abnormal Condition List DLP-114
View Alarms DLP-113
View Event Log DLP-129
View Protection Schemes DLP-115
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 36/314
3EM23954ABIssue 01, February 2010
System Information Reports2-8
IXL-103
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 37/314
3EM23954ABIssue 01, February 2010
System Administration 2-9
IXL-104
IXL-104
System Administration
Refer to table 104-A to identify a system administration function and the corresponding procedure.
Table 104-A. System Administration Functions
FUNCTION REFERENCE
Administer Network Configuration DLP-118
Administer Software License DLP-120
Administer System Date and Time DLP-119
Administer System Settings DLP-117
Administer TMN Ethernet Interface DLP-118
Download Provisioning Data DLP-116
MIB Database Management (Backup and Restore) DLP-131Provision IP Address of NE DLP-118
Provision IP Static Routing DLP-118
Provision OSPF Area Configuration DLP-118
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 38/314
3EM23954ABIssue 01, February 2010
System Administration2-10
IXL-104
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 39/314
3EM23954ABIssue 01, February 2010
Equipment Functions 2-11
IXL-105
IXL-105
Equipment Functions
Refer to table 105-A to identify an equipment function and the corresponding procedure.
Table 105-A. Auxiliary Equipment Provisioning Functions
FUNCTION REFERENCE
IF Cable Loopback DLP-130
Performance Monitoring DLP-122
Perform Protection Switching DLP-121
Perform Radio Power Measurements DLP-123
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 40/314
3EM23954ABIssue 01, February 2010
Equipment Functions2-12
IXL-105
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 41/314
3EM23954ABIssue 01, February 2010
DS1 Provisioning 3-1
NTP-100
Non-trouble Procedures (NTPs)
NTP-100
DS1 Provisioning
PURPOSE
This procedure provides instructions and sequence for provisioning DS1 facilities and equipment.
GENERAL
Three procedures are provided to provision DS1 facilities and equipment as follows:
• Provision DS1 Cross-Connect to existing DS1 port
• Provision DS1 Cross-Connect to new DS1 port
• Provision DS1 Cross-Connect to new DS1 P32E1DS1 card
STEP PROCEDURE
1 Select action?
To provision DS1 cross-connect to existing DS1 port, go to step 2.
To provision DS1 cross-connect to new DS1 port, go to step 3.
To provision DS1 Cross-Connect to new DS1 P32E1DS1 card, go to
step 4.
2 Provision DS1 cross-connect to existing DS1 port:
a. Refer to DLP-112 to provision DS1 Cross-Connect.
b. Go to step 5.
3 Provision DS1 cross-connect to new DS1 port:
a. Refer to DLP-106 to provision DS1 ports.
b. Refer to DLP-112 to provision DS1 Cross-Connect.
c. Go to step 5.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 42/314
3EM23954ABIssue 01, February 2010
DS1 Provisioning3-2
NTP-100
4 Provision DS1 Cross-Connect to new DS1 P32E1DS1 card:
a. Refer to DLP-104 to enable P32E1DS1 Card.
b. Refer to DLP-106 to provision DS1 ports.
c. Refer to DLP-112 to provision DS1 Cross-Connect.
5 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 43/314
3EM23954ABIssue 01, February 2010
DS3 Provisioning 3-3
NTP-101
NTP-101
DS3 Provisioning
PURPOSE
This procedure provides instructions and sequence for provisioning DS3 facilities and equipment.
GENERAL
Three procedures are provided to provision DS3 facilities and equipment as follows:
• Provision DS3 Cross-Connect to existing DS3 port
• Provision DS3 Cross-Connect to new DS3 port
• Provision DS3 Cross-Connect to new DS3 P2E3DS3 card
STEP PROCEDURE
1 Select action?
To provision DS3 cross-connect to existing DS3 port, go to step 2.
To provision DS3 cross-connect to new DS3 port, go to step 3.
To provision DS3 Cross-Connect to new DS3 P2E3DS3 card, go to
step 4.
2 Provision DS3 cross-connect to existing DS3 port:
a. Refer to DLP-112 to provision DS3 Cross-Connect.
b. Go to step 5.
3 Provision DS3 cross-connect to new DS3 port:
a. Refer to DLP-106 to provision DS3 ports.
b. Refer to DLP-112 to provision DS3 Cross-Connect.
c. Go to step 5.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 44/314
3EM23954ABIssue 01, February 2010
DS3 Provisioning3-4
NTP-101
4 Provision DS3 Cross-Connect to new DS3 P2E3DS3 card:
a. Refer to DLP-104 to enable P2E3DS3 Card.
b. Refer to DLP-106 to provision DS3 ports.
c. Refer to DLP-112 to provision DS3 Cross-Connect.
5 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 45/314
3EM23954ABIssue 01, February 2010
Ethernet Provisioning 3-5
NTP-102
NTP-102
Ethernet Provisioning
PURPOSE
This procedure provides instructions and sequence for provisioning Ethernet facilities and
equipment.
GENERAL
Four procedures are provided to provision Ethernet facilities and equipment as follows:
• Provision Ethernet Cross-Connect to existing CSM Ethernet port
• Provision Ethernet Cross-Connect to new CSM Ethernet port
•
Provision Ethernet Cross-Connect to new CSM SFP equipment port
• Provision Ethernet Cross-Connect to new CSM card
STEP PROCEDURE
1 Select action?
To provision Ethernet cross-connect to existing CSM Ethernet port, go
to step 2.
To provision Ethernet cross-connect to new CSM Ethernet port, go to
step 3.To provision Ethernet cross-connect to new CSM SFP equipment port,
go to step 4.
To provision Ethernet Cross-Connect to new CSM card, go to step 5.
2 Provision Ethernet cross-connect to existing CSM Ethernet port:
a. Refer to DLP-112 to provision Ethernet Cross-Connect.
b. Go to step 6.
3 Provision Ethernet cross-connect to new CSM Ethernet port:
a. Refer to DLP-108 to provision CSM Ethernet port.
b. Refer to DLP-112 to provision Ethernet Cross-Connect.
c. Go to step 6.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 46/314
3EM23954ABIssue 01, February 2010
Ethernet Provisioning3-6
NTP-102
4 Provision Ethernet cross-connect to new CSM SFP equipment port:
a. Refer to DLP-106 to provision CSM SFP equipment port.
b. Refer to DLP-108 to provision CSM Ethernet port.
c. Refer to DLP-112 to provision Ethernet Cross-Connect.
d. Go to step 6.
5 Provision Ethernet Cross-Connect to new protect CSM card:
a. Refer to DLP-104 to enable protect CSM Card.
b. Refer to DLP-106 to provision CSM SFP equipment port.
c. Refer to DLP-108 to provision CSM Ethernet port.
d. Refer to DLP-112 to provision Ethernet Cross-Connect.
6 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 47/314
3EM23954ABIssue 01, February 2010
DS1 Deprovisioning 3-7
NTP-103
NTP-103
DS1 Deprovisioning
PURPOSE
This procedure provides instructions and sequence for deprovisioning DS1 facilities and equipment.
GENERAL
Three procedures are provided to deprovision DS1 facilities and equipment as follows:
• Deprovision DS1 Cross-Connect
• Deprovision DS1 port
• Deprovision DS1 P32E1DS1 card
STEP PROCEDURE
1 Select action?
If deprovisioning DS1 cross-connect, go to step 2.
If deprovisioning DS1 port, go to step 3.
If deprovisioning DS1 P32E1DS1 card, go to step 4.
2 Deprovision DS1 cross-connect:
a. Refer to DLP-126 to deprovision DS1 cross-connect.
b. Go to step 5.
3 Deprovision DS1 port:
a. Refer to DLP-126 to deprovision DS1 Cross-Connects associated with P32E1DS1
port.
b. Refer to DLP-107 to deprovision DS1 port.
c. Go to step 5.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 48/314
3EM23954ABIssue 01, February 2010
DS1 Deprovisioning3-8
NTP-103
4 Deprovision DS1 P32E1DS1 card:
a. Refer to DLP-126 to deprovision DS1 Cross-Connects associated with P32E1DS1
card.
b. Refer to DLP-107 to deprovision DS1 ports associated with P32E1DS1 card.
c. Refer to DLP-105 to disable P32E1DS1 card.
5 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 49/314
3EM23954ABIssue 01, February 2010
DS3 Deprovisioning 3-9
NTP-104
NTP-104
DS3 Deprovisioning
PURPOSE
This procedure provides instructions and sequence for deprovisioning DS3 facilities and equipment.
GENERAL
Three procedures are provided to deprovision DS3 facilities as follows:
• Deprovision DS3 Cross-Connect
• Deprovision DS3 port
• Deprovision DS3 P2E3DS3 card
STEP PROCEDURE
1 Select action?
If deprovisioning DS3 Cross-Connect, go to step 2.
If deprovisioning DS3 port, go to step 3.
If deprovisioning DS3 P2E3DS3 card, go to step 4.
2 Deprovision DS3 cross-connect:
a. Refer to DLP-126 to deprovision DS3 Cross-Connect.
b. Go to step 5.
3 Deprovision DS3 port:
a. Refer to DLP-126 to deprovision DS3 Cross-Connect associated with DS3 port.
b. Refer to DLP-107 to deprovision DS3 port.
c. Go to step 5.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 50/314
3EM23954ABIssue 01, February 2010
DS3 Deprovisioning3-10
NTP-104
4 Deprovision DS3 P2E3DS3 card:
a. Refer to DLP-126 to deprovision DS3 Cross-Connects associated with P2E3DS3
card.
b. Refer to DLP-107 to deprovision DS3 ports associated with P2E3DS3 card.
c. Refer to DLP-105 to disable P2E3DS3 card.
5 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 51/314
3EM23954ABIssue 01, February 2010
Ethernet Deprovisioning 3-11
NTP-105
NTP-105
Ethernet Deprovisioning
PURPOSE
This procedure provides instructions and sequence for provisioning Ethernet facilities and
equipment.
GENERAL
Four procedures are provided to provision Ethernet facilities and equipment as follows:
• Deprovision Ethernet Cross-Connect from CSM Ethernet port
• Deprovision CSM Ethernet port
•
Deprovision CSM SFP equipment port
• Deprovision protect CSM card
STEP PROCEDURE
1 Select action?
To deprovision Ethernet cross-connect from CSM Ethernet port, go to
step 2.
To deprovision CSM Ethernet port, go to step 3.
To deprovision CSM SFP equipment port, go to step 4.To deprovision protect CSM card, go to step 5.
2 Deprovision Ethernet cross-connect from CSM Ethernet port:
a. Refer to DLP-126 to deprovision Ethernet cross-connect.
b. Go to step 6.
3 Deprovision CSM Ethernet port:
a. Refer to DLP-126 to deprovision Ethernet cross-connects associated with CSM
Ethernet port.
b. Refer to DLP-127 to deprovision CSM Ethernet port.
c. Go to step 6.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 52/314
3EM23954ABIssue 01, February 2010
Ethernet Deprovisioning3-12
NTP-105
4 Deprovision CSM SFP equipment port:
a. Refer to DLP-126 to deprovision Ethernet cross-connects associated with CSM
Ethernet port.
b. Refer to DLP-127 to deprovision CSM Ethernet port.
c. Refer to DLP-107 to deprovision CSM SFP equipment port.
d. Go to step 6.
5 Deprovision protect CSM card:
a. Refer to DLP-126 to deprovision Ethernet cross-connects associated with CSM
Ethernet port.
b. Refer to DLP-127 to deprovision CSM Ethernet ports associated with CSM card.
c. Refer to DLP-107 to deprovision CSM SFP equipment port.
d. Refer to DLP-105 to disable protect CSM Card.
6 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 53/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System 4-1
DLP-100
Detailed Level Procedures (DLPs)
DLP-100
Log Into and Out of System
PURPOSE
This procedure provides the instructions to establish a session with the network element (NE) and
to log in and to log out a specific user to the 9500 MPR.
PREREQUISITE
The Username and current Password must be known before login can be accomplished. 9500 MPR-A
CT R01.02 - Craft Terminal (CT) software must be installed on the PC. The user must know the IP
address of the NE to log into the system or be locally connected.
GENERAL
The 9500 MPR provides support for the Craft Terminal (CT) or WebEML (JUSM/CT) function,allowing NE management through a web-enabled PC.
The NE is accessed using the Network ElemenT Overview (NETO) application.
Four user profiles are available (Administrator, CraftPerson, Operator, and Viewer). Refer to
DLP-101 for definitions of each user profile responsibilities.
Two default user accounts are available on the NE with the profiles as follows:
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
1 Select action?
If log into JUSM/CT 9500MPR-A, go to step 2.
If log out of JUSM/CT 9500MPR-A, go to step 11.
Table 100-A. Default User Account Profiles
Username Password Profile
initial adminadmin administrator
Craftperson craftcraft Craft Person
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 54/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System4-2
DLP-100
Log Into System
2 Is NETO currently running?
If no, go to step 3.
If yes, go to step 4.
3 Double click the MPRA_CT icon on the desktop to launch NETO. See Figure 100-1.
NETO window opens. See Figure 100-2.
4 From the NETO window, enter the NE IP Address or DNS name
5 Click OK.
Figure 100-1. MPR-A R01.02 WebEML Icon
Figure 100-2. NETO Overview Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 55/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System 4-3
DLP-100
6 Click Show to launch radio application software.
“WebEML JUSM.” window opens.
7 Click OK.
The “WebEML JUSM.” window closes automatically, even if OK is not clicked.
The Login window opens. See Figure 100-3.
8 In the Login window, enter UserName “username” and Password “ password”.
9 Click Apply.
JUSM 9500MPR window launches. See Figure 100-4.
Figure 100-3. NETO Login Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 56/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System4-4
DLP-100
10 Go to step 16.
Log Out of System
11 In the upper right hand corner of the JUSM/CT window, select the “ X” . See
Figure 100-5.
The confirm request window opens.
12 Click Yes.
Figure 100-4. JUSM/CT 9500MPR-A Main Screen
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 57/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System 4-5
DLP-100
13 Close NETO application?
If yes, go to step 14.
If no, go to step 16.
14 Click Exit. See Figure 100-6.
The confirm request window opens.
15 Click Yes.
Figure 100-5. JUSM/CT 9500MPR-A Main Screen
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 58/314
3EM23954ABIssue 01, February 2010
Log Into and Out of System4-6
DLP-100
16 STOP. This procedure is complete.
Figure 100-6. NETO Overview Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 59/314
3EM23954ABIssue 01, February 2010
Administer User Profiles 4-7
DLP-101
DLP-101
Administer User Profiles
PURPOSE
This procedure provides the instructions to Create, Delete, and Change Password of a system user
for a specified UserName.
GENERAL
Only a user with system administrator privileges can create, delete and change another user’s
password.
The system allows up to 10 management users and 23 provisioned users.
There are four user profile classes. The responsibilities are as follows:
• Administrator - Full access including security parameters
• CraftPerson - Local access to radio without security parameters at the radio site.
Typical user is responsible for installation and maintenance at the radio site.
• Operator - Remote access to radio without security parameters. Typical user is
responsible for operation at the network level and not at the radio site.
• Viewer - Only view access allowed.
User Name length must not exceed 20 characters.
Passwords must meet the following complexity parameters:
• Minimum Length - Password must be at least eight characters in length
• Maximum Length - Password shall not exceed twenty characters in length
• Composition - Passwords must be composed of full ASCII characters (UPPER
case, lower case, numeric, and special characters).
Two default user accounts are available on the NE. These default user accounts can not be deleted.
For security reasons the password for the default user accounts should be changed. Refer to
Table 101-A for default user account details.
Table 101-A. Default User Account Profiles
User Name Password Profile
initial adminadmin administrator
Craftperson craftcraft CraftPerson
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 60/314
3EM23954ABIssue 01, February 2010
Administer User Profiles4-8
DLP-101
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
1 Select action.
To add new user, go to step 2.
To delete user, go to step 13.
To change a user’s password, go to step 22.
Add New User
2 Select Configuration/Profiles Management/Users Management.
The Profiles Management window opens.
Figure 101-1. User Management Drop-Down Menu
Figure 101-2. Profile Management Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 61/314
3EM23954ABIssue 01, February 2010
Administer User Profiles 4-9
DLP-101
3 Click Create.
The Create User window opens.
4 Enter the Admin Password “ AdminPassword”
5 Enter the new User Name “UserName”
6 Select user Profile class from the drop-down menu “ Administrator, CraftPerson,
Operator, or Viewer.
7 Enter the new user Password “NewUserPassword”.
8 Enter the Confirm Password “NewUserPassword”.
9 Click Apply.
User Creation Success window opens.
10 Click OK.
User Creation Success window closes.
Profile Management window opens with new user added.
Figure 101-3. Create User Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 62/314
3EM23954ABIssue 01, February 2010
Administer User Profiles4-10
DLP-101
11 Click Cancel.
12 Go to step 31.
Delete User
13 Select Configuration/Profiles Management/Users Management.
The Profiles Management window opens.
Figure 101-4. Profile Management Window - with Added User
Figure 101-5. User Management Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 63/314
3EM23954ABIssue 01, February 2010
Administer User Profiles 4-11
DLP-101
14 Select User Name to delete.
15 Click Delete.
The Deletion Confirm window opens.
16 Click Yes.
The Delete User window opens.
17 Enter the Admin Password “ AdminPassword”
18 Click Apply.
User Deletion Success window opens.
Figure 101-6. Profile Management Window
Figure 101-7. Delete User Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 64/314
3EM23954ABIssue 01, February 2010
Administer User Profiles4-12
DLP-101
19 Click OK.
The Delete User window closes.
Profile Management window opens with user deleted.
20 Click Cancel.
21 Go to step 31.
Change a User’s Password
22 Select Configuration/Profiles Management/Users Management.
The Profiles Management window opens.
Figure 101-8. Profile Management Window - with User Deleted
Figure 101-9. User Management Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 65/314
3EM23954ABIssue 01, February 2010
Administer User Profiles 4-13
DLP-101
23 Select User Name to change password.
24 Click Change PW.
The Change Password window opens.
25 Enter the Admin Password “ AdminPassword”
26 Enter the New Password “NewPassword”
27 Enter the Confirm New Password “NewPassword”.
Figure 101-10. Profile Management Window
Figure 101-11. Change User Password Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 66/314
3EM23954ABIssue 01, February 2010
Administer User Profiles4-14
DLP-101
28 Click Apply.
Changing Password Success window opens.
29 Click OK.
30 Click Cancel.
31 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 67/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE 4-15
DLP-102
DLP-102
Configure PC Network Card to Connect to NE
PURPOSE
This procedure provides the instructions for the user to configure a PC’s network card so it can
connect to the NE.
GENERAL
The user’s PC must be properly configured to communicate with the NE.
The user’s PC must be configured to obtain an IP address automatically, or the user must know the
configured IP address of the radio.
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
Configure PC Network Card
1 Connect a CAT 5/5E cable from the PC network card to the NMS connector on Slot 1
Core (CSM - Control and Switching Module) card.
2 Click on the START menu on the Windows desktop and open up the CONTROL PANEL.
3 Open up the NETWORK CONNECTIONS. Highlight the network card.
4 Right click and select Properties to display the network card properties screen.
5 Scroll down the list and highlight the Internet Protocol (TCP/IP) line.
6 Click Properties.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 68/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE4-16
DLP-102
Internet Protocol (TCP/IP) Properties window displays.
7 Configure PC network card to connect to NE?
If using DHCP, go to step 8.
If using specific NE IP address, go to step 11.
8 Select Obtain an IP address automatically. See Figure 102-2.
9 Click OK.
Figure 102-1. Internet Protocol (TCP/IP) Properties Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 69/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE 4-17
DLP-102
10 Go to step 16.
11 Write down the current IP Address that is observed in the IP address field on the
Internet Protocol (TCP/IP) Properties screen for future use, and for reference for the
Network Configuration section.
12 Select Use the following IP address. See Figure 102-3.
13 Enter the <NE IP address +1> for the PC network card into the IP address field.
14 Enter the Subnet Mask for the radio interfaced into the Subnet Mask field.
15 Click OK.
NOTE: The 10.0.1.3 IP address example shown in Figure 102-3 is derived from the default NE
IP address (10.0.1.2) plus 1. If there is an IP address conflict within your network, increment
the last number by two.
Figure 102-2. Internet Protocol (TCP/IP) Properties Window Configured for DHCP
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 70/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE4-18
DLP-102
16 Click OK.
17 Close the Network Connections window.
18 To check the connectivity between the PC and the NE, open up a DOS window or
Command Prompt. Click on the START menu on the Windows desktop and open up the
RUN window.
The Run window will display.
Figure 102-3. Internet Protocol (TCP/IP) Properties Window Configured
to Use a specific IP Address
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 71/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE 4-19
DLP-102
19 Type cmd and click OK to open up a DOS window.
The DOS window will display.
20 In the DOS window, click the cursor after the > and type ping IP Address of Radio to
verify a connection between the PC and the NE.
NOTE: The 10.0.1.2 IP address is the default NE IP address.
The Ping statistics for the IP address 10.0.1.2 should display 4 packets sent and 4
packets received.
Figure 102-4. Run Window
Figure 102-5. DOS Command Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 72/314
3EM23954ABIssue 01, February 2010
Configure PC Network Card to Connect to NE4-20
DLP-102
21 Close DOS window.
22 STOP. This procedure is complete.
Figure 102-6. Successful Ping Example
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 73/314
3EM23954ABIssue 01, February 2010
Change Password 4-21
DLP-103
DLP-103
Change Password
PURPOSE
This procedure provides the instructions for a user to change their own password.
GENERAL
The system allows a user to change their own password. Only a user with system administrator
privileges can change another person’s user password.
Passwords must meet the following complexity parameters:
• Minimum Length - Password must be at least eight characters in length
•
Maximum Length - Password shall not exceed twenty characters in length
• Composition - Passwords must be composed of full ASCII characters (UPPER
case, lower case, numeric, and special characters).
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
Change User Password
1 Select Configuration/Profiles Management/Change Password.
The Change Password window opens.
Figure 103-1. User Change Password Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 74/314
3EM23954ABIssue 01, February 2010
Change Password4-22
DLP-103
2 Enter the Old Password “OldPassword”
3 Enter the New Password “NewPassword”
4 Enter the Confirm New Password “NewPassword”.
5 Click Apply.
Changing Password Success window opens.
6 Click OK.
7 STOP. This procedure is complete.
Figure 103-2. Changing Password Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 75/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-23
DLP-104
DLP-104
Enable Equipment
PURPOSE
This procedure provides instructions to enable cards in the system.
PREREQUISITES
GENERAL
The ODU is enabled automatically when the MOD300 is enabled.
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
Enable Cards
1 Select action.
To enable protect CSM card, go to step 2.
To enable FAN card, go to step 7.
To enable MOD300 card, go to step 12.
To enable P32E1DS1 card, go to step 17.
To enable P2E3DS3 card, go to step 22.
Enable Protect CSM Card
2 Select the MSS-8/Slot#2 in the Resource Tree area. The selected slot will be highlighted
in yellow. This selection will also highlight slot #2 in blue on the graphical
representation of the MSS-8 shelf in the Resource List Area. See Figure 104-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 76/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-24
DLP-104
3 Click on the Settings Tab in the Resource Detail Area.
4 Select the Equipment Type drop-down menu and select CORE. See Figure 104-2.
Figure 104-1. Select Slot 2 to Enable Protect CSM
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 77/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-25
DLP-104
5 Click Apply.
The protect CSM card will populate slot #2. See Figure 104-3.
Figure 104-2. Select Protect CSM Equipment Type
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 78/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-26
DLP-104
6 Go to step 26.
Enable Fan
7 Select the MSS-8/Slot9 in the Resource Tree area where the FAN card will be enabled.
The selected slot will be highlighted in yellow. This selection will also highlight slot 9
in blue on the graphical representation of the MSS-8 shelf in the Resource List Area.
See Figure 104-4.
Figure 104-3. Protect CSM Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 79/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-27
DLP-104
8 Click on the Settings Tab in the Resource Detail Area.
9 Select the Equipment Type drop-down menu and choose FANS. See Figure 104-5.
Figure 104-4. Select Slot 9 to Enable FAN
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 80/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-28
DLP-104
10 Click Apply.
The FAN card will populate slot #9. See Figure 104-6.
Figure 104-5. Select FAN Equipment Type
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 81/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-29
DLP-104
11 Go to step 26.
Enable MOD300 Radio Card
12 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
MOD300 card will be enabled. The selected slot will be highlighted in yellow. This
selection will also highlight the selected slot in blue on the graphical representation of
the MSS-8 shelf in the Resource List Area. See Figure 104-7.
Figure 104-6. FAN Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 82/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-30
DLP-104
13 Click on the Settings Tab in the Resource Detail Area.
14 Select the Equipment Type drop-down menu and choose MD300 (MOD300). See
Figure 104-8.
Figure 104-7. Select Slot to Enable MOD300
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 83/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-31
DLP-104
15 Click Apply.
The MOD300 card will populate selected slot #. See Figure 104-9.
Figure 104-8. Select MD300 Equipment Type
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 84/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-32
DLP-104
16 Go to step 26.
Enable DS1 P32E1DS1 Card
17 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
P32E1DS1 card will be enabled. The selected slot will be highlighted in yellow. This
selection will also highlight the selected slot in blue on the graphical representation of
the MSS-8 shelf in the Resource List Area. See Figure 104-10.
Figure 104-9. MOD300 Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 85/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-33
DLP-104
18 Click on the Settings Tab in the Resource Detail Area.
19 Select the Equipment Type drop-down menu and select P32E1DS1. See Figure 104-11.
Figure 104-10. Select Slot to Enable P32E1DS1
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 86/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-34
DLP-104
20 Click Apply.
The P32E1DS1 card will populate selected slot #. See Figure 104-12.
Figure 104-11. Select P32EDS1 Equipment Type
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 87/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-35
DLP-104
21 Go to step 26.
Enable DS3 P2E3DS3 Card
22 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
P2E3DS3 card will be enabled. The selected slot will be highlighted in yellow. This
selection will also highlight the selected slot in blue on the graphical representation of
the MSS-8 shelf in the Resource List Area. See Figure 104-13.
Figure 104-12. P32E1DS1 Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 88/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-36
DLP-104
23 Click on the Settings Tab in the Resource Detail Area.
24 Select the Equipment Type drop-down menu and select P2E3DS3. See Figure 104-14.
Figure 104-13. Select Slot to Enable P2E3DS3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 89/314
3EM23954ABIssue 01, February 2010
Enable Equipment 4-37
DLP-104
25 Click Apply.
The P2E3DS3 card will populate selected slot #. See Figure 104-15.
Figure 104-14. Select P2E3DS3 Equipment Type
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 90/314
3EM23954ABIssue 01, February 2010
Enable Equipment4-38
DLP-104
26 STOP. This procedure is complete.
Figure 104-15. P2E3DS3 Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 91/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-39
DLP-105
DLP-105
Disable Equipment
PURPOSE
This procedure provides instructions to Disable cards in the system.
PREREQUISITES
Associated facilities and equipment ports must be deprovisioned before a card may be disabled.
GENERAL
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
Disable Cards
1 Select action.
To disable protect CSM card, go to step 2.
To disable FAN card, go to step 7.
To disable MOD300 card, go to step 12.
To disable ODU card, go to step 16.
To disable P32E1DS1 card, go to step 18.
To disable P2E3DS3 card, go to step 23.
Disable Protect CSM Card
2 Select the MSS-8/Slot#2 in the Resource Tree area. The selected slot will be highlighted
in yellow. This selection will also highlight spare CSM card in slot #2 in blue on the
graphical representation of the MSS-8 shelf in the Resource List Area. See
Figure 105-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 92/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-40
DLP-105
3 Click on the Settings Tab in the Resource Detail Area.
4 Select the Equipment Type drop-down menu and select EMPTY. See Figure 105-2.
Figure 105-1. Enabled Spare CSM
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 93/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-41
DLP-105
5 Click Apply.
The spare CSM card is removed from slot #2. See Figure 105-3.
NOTE: Spare CSM Card will not be disabled if the card has cross-connects and/or equipment
ports associated.
Figure 105-2. Disable Protect CSM
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 94/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-42
DLP-105
6 Go to step 27.
Disable Fan
7 Select the MSS-8/Slot9 in the Resource Tree area where the FAN card will be disabled.
The selected slot will be highlighted in yellow. This selection will also highlight slot 9,
MSS/FANS in blue on the graphical representation of the MSS-8 shelf in the Resource
List Area. See Figure 105-4.
Figure 105-3. Protect CSM Disabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 95/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-43
DLP-105
8 Click on the Settings Tab in the Resource Detail Area.
9 Select the Equipment Type drop-down menu and select EMPTY. See Figure 105-5.
Figure 105-4. Enabled FAN
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 96/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-44
DLP-105
10 Click Apply.
The FAN card is removed from slot #9. See Figure 105-6.
Figure 105-5. Disable FAN
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 97/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-45
DLP-105
11 Go to step 27.
Disable MOD300 Radio Card
12 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
MOD300 card is enabled. The selected slot will be highlighted in yellow. This selection
will also highlight the selected MSS/MOD300 in blue on the graphical representation
of the MSS-8 shelf in the Resource List Area. See Figure 105-7.
Figure 105-6. FAN Disabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 98/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-46
DLP-105
13 Click on the Settings Tab in the Resource Detail Area.
14 Select the Equipment Type drop-down menu and choose EMPTY. See Figure 105-8.
Figure 105-7. Enabled MOD300
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 99/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-47
DLP-105
15 Click Apply.
The MOD300 card is removed from selected slot #. See Figure 105-9.
Figure 105-8. Disable MOD300
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 100/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-48
DLP-105
16 Go to step 27.
Disable ODU
NOTE: The ODU is automatically disabled when the MOD300 card is disabled.
17 Go to step 27.
Disable DS1 P32E1DS1 Card
18 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
P32E1DS1 card will be disabled. The selected slot will be highlighted in yellow. This
selection will also highlight the selected slot in blue on the graphical representation of
the MSS-8 shelf in the Resource List Area. See Figure 105-10.
Figure 105-9. MOD300 Disabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 101/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-49
DLP-105
19 Click on the Settings Tab in the Resource Detail Area.
20 Select the Equipment Type drop-down menu and select EMPTY. See Figure 105-11.
21 Click Apply.
Figure 105-10. Enabled P32E1DS1
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 102/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 103/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-51
DLP-105
22 Go to step 27.
Disable DS3 P2E3DS3 Card
23 Select the MSS-8/Slot# (slot 3 through 8) in the Resource Tree area where the
P2E3DS3 card will be disabled. The selected slot will be highlighted in yellow. This
selection will also highlight the selected slot in blue on the graphical representation of
the MSS-8 shelf in the Resource List Area. See Figure 105-13.
Figure 105-12. Disabled P32E1DS1
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 104/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-52
DLP-105
24 Click on the Settings Tab in the Resource Detail Area.
25 Select the Equipment Type drop-down menu and select EMPTY. See Figure 105-14.
Figure 105-13. Enabled P2E3DS3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 105/314
3EM23954ABIssue 01, February 2010
Disable Equipment 4-53
DLP-105
26 Click Apply.
The P2E3DS3 card disabled will be removed from the selected slot #. See
Figure 105-15.
NOTE: P2E3DS3 Card will not be disabled if the card has cross-connects and/or equipment
ports associated.
Figure 105-14. Disable P2E3DS3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 106/314
3EM23954ABIssue 01, February 2010
Disable Equipment4-54
DLP-105
27 STOP. This procedure is complete.
Figure 105-15. Disabled P2E3DS3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 107/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-55
DLP-106
DLP-106
Provision Equipment Ports
PURPOSE
This procedure is used to provision equipment ports.
GENERAL
While provisioning PDH circuits (DS1 or DS3) the service profile must be provisioned either
TDM2TDM or TDM2ETH.
Provision the PDH circuit TDM2TDM when both termination points of the PDH circuit are
terminated on 9500 MPR equipment.
Provision the PDH circuit TDM2ETH when one of the termination points of the PDH circuit is
terminated on non-9500 MPR equipment, and the other equipment is MEF-8 compliant.
PREREQUISITES
CSM, DS1 (P32E1DS1) or DS3 (P2E3DS3) cards must be enabled into the MSS-8 shelf slots prior to
provisioning equipment ports.
STEP PROCEDURE
Provision Equipment Ports
1 Select action.
To provision CSM, SFP port, go to step 2.
To provision P32E1DS1, DS1 port, go to step 7.
To provision P2E3DS3, DS3 port, go to step 21.
Provision CSM SFP Port
2 Select slot #1 or #2 below the slot the MSS/CSM card is equipped in the Resource Tree
area. The selected name will highlighted in yellow.
3 Click on the Settings Tab in the Resource Detail Area. See Figure 106-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 108/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-56
DLP-106
4 Select Equipment Type drop-down menu, select type SFP. See Figure 106-2.
Figure 106-1. Resource List Area: CSM SFP Slot Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 109/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-57
DLP-106
5 Click Apply.
The CSM SFP port will populate selected slot #. See Figure 106-3.
NOTE: CSM Ports 1-4 and port selected SFP are ready for provisioning.
Figure 106-2. Provision CSM SFP Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 110/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-58
DLP-106
6 Go to step 36.
Provision DS1 P32E1DS1 Port
7 Double left click the DS1 (P32E1DS1) card in the Resource List Area. See
Figure 106-4.
Figure 106-3. Provisioned CSM SFP Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 111/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-59
DLP-106
The Alarms&Settings screen displays.
8 Select Settings tab. See Figure 106-5.
Figure 106-4. Resource List Area: P32E1DS1 Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 112/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-60
DLP-106
See Figure 106-6 for the following steps:
9 Select DS1 port number to provision: 01 to 32 .
10 Select the Signal Mode drop-down menu and select signal mode type: Unframed,Framed SF, or Framed ESF.
11 Select the appropriate Line Coding radio button: AMI or B8ZS.
12 Enter the Line Length (distance to cross-connect): 0 to 655 .
13 Enter the unique Flow ID number.
Figure 106-5. Provision P32E1DS1 Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 113/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-61
DLP-106
14 Select the Service Profile drop-down menu and select service profile type, TDM2TDM or
TDM2ETH.
15 Click Apply.
16 DS1 port service profile TDM2ETH? See Figure 106-7.
If yes, go to step 17.
If no, go to step 20.
Figure 106-6. Provisioned P32E1DS1 TDM2TDM Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 114/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-62
DLP-106
Provision TDM2ETH Service Profile
See Figure 106-8 for the following steps:
17 Enter the unique ECID Tx value.
18 Enter the unique ECID Rx value.
19 Click Apply.
Figure 106-7. Provision P32E1DS1 for TDM2ETH Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 115/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-63
DLP-106
20 Go to step 36.
Provision DS3 P2E3DS3 Port
21 Double left click the MSS/DS3 (P2E3DS3) card in the Resource List Area. SeeFigure 106-9.
Figure 106-8. Provisioned P32E1DS1 TDM2ETH Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 116/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-64
DLP-106
The Alarms&Settings screen displays.
22 Select Settings tab. See Figure 106-10.
Figure 106-9. Resource List Area: P2E3DS3 Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 117/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 118/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 119/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports 4-67
DLP-106
Provision TDM2ETH Service Profile
See Figure 106-13 for the following steps:
31 Select the Payload Size drop-down menu and select payload size in Mb/s.
32 Select the TDM Clock Source drop-down menu and select TDM Clock Source: Adaptive
or Differential.
33 Enter the unique ECID Tx value.
34 Enter the unique ECID Rx value.
Figure 106-12. Provision P2E3DS3 for TDM2ETH Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 120/314
3EM23954ABIssue 01, February 2010
Provision Equipment Ports4-68
DLP-106
35 Click Apply.
36 STOP. This procedure is complete.
Figure 106-13. Provisioned P2E3DS3 TDM2ETH Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 121/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 122/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports4-70
DLP-107
Deprovision CSM SFP Port#5
4 Select Equipment Type drop-down menu, select type EMPTY. See Figure 107-2.
Figure 107-1. Resource List Area: CSM SFP Slot Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 123/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports 4-71
DLP-107
5 Click Apply.
The selected CSM slot SFP port #5 will display empty. See Figure 107-3.
NOTE: CSM Port #5 will not deprovision if the port has any Cross-Connections associated
with the port.
Figure 107-2. Provisioned CSM SFP Port #5
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 124/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports4-72
DLP-107
6 Go to step 18.
Deprovision DS1 P32E1DS1 Port
7 Double left click the DS1 (P32E1DS1) card in the Resource List Area. See
Figure 107-4.
Figure 107-3. Deprovisioned CSM SFP Port#5
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 125/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 126/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports4-74
DLP-107
See Figure 107-6 for the following steps:
9 Select DS1 port number to deprovision: 01 to 32 .
10 Select the Signal Mode drop-down menu and select signal mode type: Disabled.
11 Click Apply.
Figure 107-5. Provisioned P32E1DS1
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 127/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports 4-75
DLP-107
Deprovisioned port will display Disabled. See Figure 107-7.
NOTE: P32E1DS1 Ports will not deprovision if the port has a Cross-Connection associated
with the port.
Figure 107-6. Deprovision P32E1DS Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 128/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 129/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports 4-77
DLP-107
The Alarms&Settings screen displays.
14 Select Settings tab. See Figure 107-9.
Figure 107-8. Resource List Area: P2E3DS3 Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 130/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports4-78
DLP-107
See Figure 107-10 for the following steps:
15 Select DS3 port number to deprovision, 01 or 02.
16 Select the Signal Mode drop-down menu and select signal mode type: Disabled.
17 Click Apply.
Figure 107-9. Provisioned P2E3DS3
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 131/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports 4-79
DLP-107
Deprovisioned port will display Disabled. See Figure 107-11.
NOTE: P2E3DS3 Ports will not deprovision if the port has a Cross-Connection associated
with the port.
Figure 107-10. Deprovision P2E3DS3 Port
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 132/314
3EM23954ABIssue 01, February 2010
Deprovision Equipment Ports4-80
DLP-107
18 STOP. This procedure is complete.
Figure 107-11. Deprovisioned P2E3DS3 Ports
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 133/314
3EM23954ABIssue 01, February 2010
Provision Ethernet Ports 4-81
DLP-108
DLP-108
Provision Ethernet Ports
PURPOSE
This procedure is used to provision Ethernet ports.
GENERAL
CSM card provisioning requirements depend on how the Ethernet and NMS ports on the front panel
of the card are being used. If the CSM Ethernet ports are being used to interface external Ethernet
equipment and TMN (SNMP) is not being used to monitor and control the NE, then only the Ethernet
Physical Interface needs to be provisioned. The TMN Interface is disabled. If Ethernet port 4 or the
NMS port on the CSM card is being used to transport TMN data, then both the Ethernet Physical
Interface and TMN Interface need to be provisioned.
The NMS port is normally reserved for Craft Terminal interface with the PC. When enabled, theNMS port can be used to daisy chain TMN data to other equipment at the site. The serial data
interface with the PC for the Craft Terminal on the NMS port is always enabled and requires no
special provisioning.
STEP PROCEDURE
1 Select action.
To Provision CSM 10/100/1000 BaseT Ethernet Interfaces, go to step 2.
To Provision CSM Ethernet SFP Interface, go to step 13.
Provision Physical CSM Ethernet Interfaces
10/100/1000 Base T Ethernet Interfaces
2 Select the MSS/Core-Main slot #n in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area.
3 Double left click the blue MSS/Core-Main (CSM) Card.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 134/314
3EM23954ABIssue 01, February 2010
Provision Ethernet Ports4-82
DLP-108
Ethernet Physical Interface Settings Tab will display.
4 Select Ethernet Physical Interface tab.
5 Select Ethernet Port number to provision (Ethernet Port #1/#4 ).
6 Selecting Settings tab.
Figure 108-1. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 135/314
3EM23954ABIssue 01, February 2010
Provision Ethernet Ports 4-83
DLP-108
7 Enable Port Status, select enabled [checked].
8 Click Port Status Apply button to enable port status.
9 Select auto-negotiation parameters to correspond to capabilities of link partner:
a. Select Advertised Capability: 10 Mb/s - Half Duplex, 10 Mb/s - Full Duplex, 100
Mb/s - Half Duplex, 100 Mb/s - Full Duplex, or 1000 Mb/s - Full Duplex.
b. Select Auto Negotiation Status: disabled (unchecked), or enabled (checked).
c. Select Flow Control: (disabled [unchecked], or enabled [checked]).
10 Click Apply.
Figure 108-2. CSM Ethernet Physical Interface: Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 136/314
3EM23954ABIssue 01, February 2010
Provision Ethernet Ports4-84
DLP-108
11 Close window.
12 Go to step 23.
Provision CSM Ethernet SFP Interface
13 Select the MSS/Core-Main slot #1 in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area.
14 Double left click the blue MSS/Core-Main (CSM) Card and the Settings Tab for the
Ethernet Physical Interface will display.
Ethernet Physical Interface Settings Tab will display.
15 Select Ethernet Physical Interface tab.
16 Select Ethernet Port number #5 .
17 Selecting Settings tab.
Figure 108-3. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 137/314
3EM23954ABIssue 01, February 2010
Provision Ethernet Ports 4-85
DLP-108
18 Enable Port Status, select Enabled [checked].
19 Click Port Status Apply.
20 Select auto-negotiation parameters to correspond to capabilities of link partner:
a. Select Auto Negotiation Status: disabled (unchecked), or enabled (checked).
b. Select Flow Control: (disabled [unchecked], or enabled [checked]).
21 Click Apply.
Figure 108-4. CSM Ethernet Physical Interface: SFP Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 138/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 139/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 140/314
3EM23954ABIssue 01, February 2010
Provision Radio Parameters4-88
DLP-109
3 Configure radio with fixed or adaptive modulation?
If fixed modulation, go to step 4.
If adaptive modulation, go to step 12.
Provision Fixed Modulation
4 From the Mode drop-down menu select Presetting.
5 From the Reference Channel Spacing drop-down menu, select desired channel spacing
(10, 30, 40, or 50 MHz).
6 From the Modulation drop-down menu, select modulation scheme (4, 16, 32, 128, or
256 QAM).
Figure 109-2. Provision Radio Channel Fixed Modulation Parameters
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 141/314
3EM23954ABIssue 01, February 2010
Provision Radio Parameters 4-89
DLP-109
7 Select the Channel #1 shifter frequency, from the channel #1 Shifter (MHz) drop-down
menu, choose the TX (Go) and RX (Return) Separation Frequency.
8 When the ODU is connected to the MSS-8 shelf, the Channel #1 TxFreq(KHz) field is
automatically populated. If the ODU is not connected, enter the TX RF Frequency
within the allowed range.
9 The Rx Freq (KHz) displays the Rx RF Frequency.
NOTE: The Channel #1 Rx Freq (KHz) field displays the Rx RF Frequency and is the result of
the following calculation:
RX Frequency = TX Frequency - Shifter Frequency
10 Click Apply.
NOTE: In a Protected MOD300 configuration, the Main and Protect MOD300cards use the same CT screen. The parameters on the Main (Channel #1) part
of the screen is a mirror image of the Protect (Channel #0) part of the screen.
Channel #0 fields will be automatically filled in to match Channel #1.
11 Go to step 19.
Provision Adaptive Modulation
12 From the Mode drop-down menu select Adaptive Modulation.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 142/314
3EM23954ABIssue 01, February 2010
Provision Radio Parameters4-90
DLP-109
13 From the Modulation range drop-down menu, select modulation range.
14 From the Reference Channel Spacing drop-down menu, select desired channel spacing
(10 or 30 MHz).
15 Select the Channel #1 shifter frequency, from the channel #1 Shifter (MHz) drop-down
menu, choose the TX (Go) and RX (Return) Separation Frequency.
16 When the ODU is connected to the MSS-8 shelf, the Channel #1 TxFreq(KHz) field is
automatically populated. If the ODU is not connected, enter the TX RF Frequency
within the allowed range.
Figure 109-3. Provision Radio Channel Adaptive Modulation Parameters
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 143/314
3EM23954ABIssue 01, February 2010
Provision Radio Parameters 4-91
DLP-109
17 The Rx Freq (KHz) displays the Rx RF Frequency.
NOTE: The Channel #1 Rx Freq (KHz) field displays the Rx RF Frequency and is the result of
the following calculation:
RX Frequency = TX Frequency - Shifter Frequency
18 Click Apply.
NOTE: In a Protected MOD300 configuration, the Main and Protect MOD300
cards use the same CT screen. The parameters on the Main (Channel #1) part
of the screen is a mirror image of the Protect (Channel #0) part of the screen.
Channel #0 fields will be automatically filled in to match Channel #1.
Provision MOD300 Radio Protection Scheme
19Select the MSS/RADIO Dir#-Ch# in the Resource Tree area. The selected name will be
highlighted in yellow. This selection also highlights the MOD300 Card icon in blue in
the resource List Area.
20 Select Settings tab.
Figure 109-4. MOD300 Radio Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 144/314
3EM23954ABIssue 01, February 2010
Provision Radio Parameters4-92
DLP-109
21 Select the Protection Type drop-down menu and select: No Protection, 1+1 HSB, or 1+1
FD protection scheme.
22 Select the Protect port.
23 Click Apply.
24 STOP. This procedure is complete.
Figure 109-5. MOD300 Radio Protection Provisioned
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 145/314
3EM23954ABIssue 01, February 2010
Provision Synchronization 4-93
DLP-110
DLP-110
Provision Synchronization
PURPOSE
This procedure is used to provision NE synchronization.
GENERAL
All 9500 MPR radios in the network must be synchronized to the same clock. One radio in the
network is provisioned Master. All other radios in the network must be provisioned Slave. The slave
radios all sync to the clock provided by the master.
STEP PROCEDURE
1 Select the Synchronization tab.
2 Select Synchronization Source icon in the Resource Tree Area.
3 Click on the Settings Tab in the Resource Detail Area.
Figure 110-1. Synchronization Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 146/314
3EM23954ABIssue 01, February 2010
Provision Synchronization4-94
DLP-110
4 Provision which synchronization role?
If master, then go to step 5.
If slave, go to step 19.
Provision Master Synchronization
5 Select Master radio button in the Role partition.
6 Select Restoration mode radio button desired: Revertive or Not Revertive.
7 Select Primary Source radio button desired: Free Run Local Oscillator , E1/DS1 Port, or
Sync-In Port.
8 Which primary source was selected?
If Sync-In Port, go to step 9.
If E1/DS1 Port, select the E1/DS1 Port from the drop-down menu. Then
go to step 12.
If Free Run Local Oscillator, go to step 17.
9 In the Sync Ports partition, select the Sync In port frequency from the Sync-In Port
drop-down menu: 2.048 MHz, 5 MHz, or 10 MHz.
10 Select Secondary Source radio button desired: Free Run Local Oscillator , or E1/DS1 Port.
11 Go to step 13.
12 Select Secondary Source radio button desired: Free Run Local Oscillator , E1/DS1 Port, orSync-In Port.
13 Which secondary source was selected?
If Free Run Local Oscillator, go to step 15.
If E1/DS1 Port, select the E1/DS1 Port from the drop-down menu. Then
go to step 15.
If Sync-In Port, go to step 14.
14 In the Sync Ports partition, select the Sync In port frequency from the Sync-In Port
drop-down menu: 2.048 MHz, 5 MHz, or 10 MHz.
15 Provision Sync Out Port?
If yes, go to step 16.
If no, go to step 17.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 147/314
3EM23954ABIssue 01, February 2010
Provision Synchronization 4-95
DLP-110
16 In the Sync Ports partition, select the Sync Out port frequency from the Sync-Out Port
drop-down menu: 2.048 MHz, 5 MHz, or 10 MHz.
17 Click Apply.
18 Go to step 31.
Provision Slave Synchronization
19 Select Slave radio button in the Role partition.
20 Select Primary Source radio button desired: Sync-In Port, or Radio Port.
21 Which primary source was selected?
If Sync-In Port, go to step 22.
If Radio Port, select the Radio Port from the drop-down menu. Then go
to step 25.
22 In the Sync Ports partition, select the Sync In port frequency from the Sync-In Port
drop-down menu: 2.048 MHz, 5 MHz, or 10 MHz.
Figure 110-2. Synchronization - Master / Revertive
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 148/314
3EM23954ABIssue 01, February 2010
Provision Synchronization4-96
DLP-110
23 Select Secondary Source radio button desired: Free Run Local Oscillator or E1/DS1 Port.
24 Go to step 28.
25 Select Secondary Source radio button desired: Free Run Local Oscillator , E1/DS1 Port, orSync-In Port.
26 Which secondary source was selected?
If Free Run Local Oscillator, go to step 28.
If E1/DS1 Port, select the E1/DS1 Port from the drop-down menu. Then
go to step 28.
If Sync-In Port, go to step 27.
27 In the Sync Ports partition, select the Sync In port frequency from the Sync-In Port
drop-down menu: 2.048 MHz, 5 MHz, or 10 MHz.
28 Provision Sync Out Port?
If yes, go to step 29.
If no, go to step 30.
29 In the Sync Ports partition, select the Sync Out port frequency from the Sync-Out Port
drop-down menu: NOT USED, 2.048 MHz, 5 MHz, or 10 MHz.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 149/314
3EM23954ABIssue 01, February 2010
Provision Synchronization 4-97
DLP-110
30 Click Apply.
31 STOP. This procedure is complete.
Figure 110-3. Synchronization - Slave / Revertive
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 150/314
3EM23954ABIssue 01, February 2010
Provision Synchronization4-98
DLP-110
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 151/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-99
DLP-112
DLP-112
Provision Cross Connections
PURPOSE
This procedure is used to provision cross connections.
GENERAL
Cross connection is only required for TDM traffic. Generic Ethernet traffic is handled automatically
via MAC Address learning in the Ethernet switch. Cross connections can also be used with point-to-
point VLAN Ethernet traffic to direct traffic based on a VLAN tag rather than MAC address.
The cross connections screen is used to configure switching of packetized data through the CSM
(Control and Switching Module - Core) card. Using this screen, the operator can switch:
• DS1/DS3 (ports) lines from/to a P32E1DS1/P2E3DS3 (PDH DS1/DS3 icons) cardto/from a MOD300 (RADIO icons) card and/or any of four Ethernet (ETH icons)
ports on the CSM card.
• Ethernet (ETH icons) data from/to an external source to/from a MOD300 (RADIO
icons) card and/or to/from an P32E1DS1/P2E3DS3 (PDH DS1/DS3 icons) card.
The screen allows the operator to select DS1/DS3 (PDH icons), Ethernet (ETH icons), and/or
MOD300 (RADIO icons) ports as source and destination ports and provides a graphical presentation
of the switch functions.
The license key installed on the CSM determines the Ethernet data capacity that can be crossconnected.
Valid Cross Connections:
• PDH to Radio:
– PDH (P32E1DS1 card) to RADIO (MOD300 card)
– PDH (P2E3DS3 card) to RADIO (MOD300 card)
• PDH to Ethernet:
– PDH (P32E1DS1 card) to ETH (Ethernet)
– PDH (P2E3DS3 card) to ETH (Ethernet)
• Ethernet to Radio:
• Radio to Radio:
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 152/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-100
DLP-112
After a cross connection has been created, two cross connected slots are visually linked by a line: a
line in the context of this application represents a bundle of flows, which share same source and
destination entity. In addition, all 802.1Q tagged Ethernet traffic having the same VLAN ID as cross
connection Flow ID number will only be forwarded between these cross connected slots.
Point to Point VLAN
The Point to Point (P2P) VLAN cross connect feature allows the user to direct VLAN-tagged traffic
between specified Ethernet and/or radio ports. Rather than directing all traffic to and from the cross
connected ports, the feature directs Ethernet traffic where the VLAN tag matches the cross connect
Flow ID.
• When making the connection for a P2P VLAN flow (Ethernet port to radio), the
user should enter a MAC address of all 0's (000000000000). P2P VLAN cross
connects will direct matching VLAN-tagged Ethernet traffic to the cross
connected ports regardless of the destination MAC address in the Ethernet
frames.
• Ethernet traffic entering the cross connected port with a VLAN tag matching the
flow id will be directed only to the port on the other end of the cross connect.
Traffic will not be flooded. This will also take precedence over any MAC address
learning for VLAN-tagged traffic that matches the flow id in the cross connect.
• Ethernet traffic entering the cross connected port with no VLAN tag or VLAN tags
that do not match the flow id specified in the cross connect will flood to all ports
until MAC address learning takes place. The P2P VLAN cross connect will have
no effect on this traffic.
• VLAN tagged Ethernet traffic that enters a port will be dropped if the VLAN tag matches the
flow id of a cross connect that is on a different port.
The user must know the Ethernet VLAN ID, provisioned by the customer, before provisioning/cross
connecting DS1/DS3 data lines.
Each radio link can handle a maximum of 256 VLAN IDs.
When configuring MPLS T1's via ethernet through a multi-path 9500 MPR network (Nx1+0/1),
Point-to-Point VLAN (P2P VLAN) cross-connects will be required to restrict the traffic to one
radio/Ethernet port combination. This is because the multiple path connections will deliver several
copies of the LDP messages between the MPLS T1's NE's causing regular traffic interruptions. When
there are 3 radio links between the same two shelves, 3 copies of each LDP message are delivered to
the MPLS T1's. Creating the P2P VLAN Cross-Connect between the ethernet port and radio (wherethe MPLS T1's connects) allows only one copy of the message to reach the MPLS T1's and corrects
the problem.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 153/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-101
DLP-112
Flow ID number Rules
The Flow ID number entered by the operator on the MSS/DS1 or MSS/DS3 provisioning screen is
one of the parameters the software management uses to determine source, destination, and direction
of the DS1/DS3 port when the data is switched in the Core (CSM) card. The following rules apply to
the Flow ID:
1. Number is unique to the entire network. It cannot be used in any other radio or
hop in the network.
2. Range of Flow ID numbers to choose from is determined by total number of Flow
ID's in the network. Refer to Table 112-A for Range of Flow ID's. If there are fewer
than 256 cross connects in the network, select Flow ID from the Less Than or Equal
to 256 Range. If there are more than 256 but less than 512 cross connects, select
Flow ID from the More Than 256, Less Than 512 Range.
Ranging
Ranging allows the operator to enter multiple cross-connects simultaneously. When multiple
cross-connections are required between the same two ports, the MAC Address is the same, andmultiple Flow IDs are to be cross-connected, ranging can be used to enter the cross-connections at
the same time.
When multiple cross-connections are required between the same two ports, the MAC Address is the
same, and the Flow IDs are sequential, ranging can be used to enter the cross-connections at the
same time. In the Flow ID field, enter the end points of the sequence using the notation [n-m]; where
‘n’ equals the start value of the sequence and ‘m’ equals the stop value of the sequence. Example: to
enter cross-connections for Flow IDs 147 through 156, in the Flow ID field enter “147-156 ”. See
Figure 112-1.
When multiple cross-connections are required between the same two ports, the MAC Address is the
same, and the Flow IDs are not sequential, ranging can be used to enter the cross-connections at thesame time. In the Flow ID field, enter the multiple Flow IDs separated by commas. Example: to enter
cross-connections for Flow IDs 47, 62, 135, and 201, in the Flow ID field enter “47,62,135,201”. See
Figure 112-2.
To ensure successful completion of the cross-connection requests, the user should limit the number
of cross-connections created using a single ranging operation to ten.
Ranging is supported for Radio to Radio and Ethernet to Radio Cross-Connection entry.
Table 112-A. Range of Flow ID’s
Flow ID Range
Less Than or
Equal to 256
2-255, 256-511, 512-767, 768-1023, 1024-1279, 1280-1535, 1536-1791, 1792-
2047, 2048-2303, 2304-2559, 2560-2815, 2816-3071, 3072-3327, 3328-3583,
3584-3839, 3840-4080
More Than 256,
Less Than 512
2-511, 512-1023, 1024-1535, 1536-2047, 2048-2559, 2560-3071, 3072-3583,
3584-4080
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 154/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-102
DLP-112
Ranging is supported for PtP VLAN Cross-Connection entry.
Destination MAC Address
The destination MAC address is dependent upon the protection scheme of the destination port. For
destination ports which are configured unprotected, the first two digits of the destination MAC
Address must be set to ‘unicast’ or ‘00’. For destination ports which are configured 1+1 protection,
the first two digits of the destination MAC Address must be set to ‘multicast’ or ‘01’.
The destination MAC address for P2P VLAN cross-connects must be set to ‘00:00:00:00:00:00’.
Example #1: The destination port is unprotected and the NE MAC Address is “00:43:23:19:87:92”. In
the Cross Connection MAC Address field, enter: “00 :43:23:19:87:92”.
Example #2: The designating port is 1+1 protected and the NE MAC Address is “00:43:23:19:87:92”.
In the Cross Connection MAC Address field, enter: “01:43:23:19:87:92”.
Example #3: The cross-connect is a P2P VLAN, the destination port is set to “00:00:00:00:00:00”. In
the Cross Connection MAC Address field, enter: “00:00:00:00:00:00”.
Figure 112-1. Ranging Sequential Flow IDs
Figure 112-2. Ranging Non-Sequential Flow IDs
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 155/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-103
DLP-112
PDH to Radio:
CAUTION: Possibility of service interruption. In the protected CSM configuration,
entering DS1 cross-connections while the spare CSM is Active may affect existing DS1
cross-connections. To prevent this from occurring, ONLY provision DS1
cross-connections while the main CSM card is Active.
PREREQUISITES
Each DS1/DS3 card and MOD300 card must be enabled on the respective DS1/DS3 and MOD300
card provisioning screens.
The Service Profile on the each DS1/DS3 card Settings screen must be set to TDM2TDM for each
DS1/DS3 cross connect when both termination points of the DS1/DS3 circuit are terminated on
9500 MPR equipment.
The Service Profile on the each DS1/DS3 card Settings screen must be set to TDM2ETH for each
DS1/DS3 cross connect when one of the termination points of the DS1/DS3 circuit are terminated onnon-9500 MPR equipment, and the other equipment is MEF-8 compliant.
Each DS1/DS3 line to be cross connected must have a unique Flow ID number assigned to it on the
respective DS1/DS3 card Settings screen.
PDH to Ethernet:
CAUTION: Possibility of service interruption. In the protected CSM configuration,
entering DS1 cross-connections while the spare CSM is Active may affect existing DS1
cross-connections. To prevent this from occurring, ONLY provision DS1
cross-connections while the main CSM card is Active.
PREREQUISITES
The DS1/DS3 card (source) and CSM card (destination) must be enabled on the respective DS1/DS3
card and CSM card provisioning screens.
The Service Profile on the DS1/DS3 card Settings screen must be set to TDM2ETH for each DS1/DS3
cross connected.
Ethernet to Radio:
PREREQUISITES
The Ethernet port (source) and MOD300 card (destination) must be enabled on the respective CSMand MOD300 card provisioning screens.
Ranging Flow ID entry is supported.
The Service Profile on theDS1/DS3 card Settings screen must be set to TDM2ETH for each DS1/DS3
cross connected.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 156/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-104
DLP-112
Radio to Radio:
PREREQUISITES
Both MOD300 cards must be enabled on the respective MOD300 card provisioning screens.
• When making a cross connection between two radio cards, use the TDM2TDM
service profile if the termination points of the circuit are configured TDM2TDM.
• Use the TDM2ETH service profile if the termination points of the circuit are
configured TDM2ETH.
• Use the TDM2ETH service profile when making the point-to-point VLAN
connection.
Ranging Flow ID entry is supported.
The Service Profile on the DS1/DS3 card Settings screen must be set for each DS1/DS3 cross connected.
Icon Shapes
The shape of the icon identifies the module in the slot as RADIO (MD300 module) or PDH
(P32E1DS1/P2E3DS3 modules) or one of four ETH (Ethernet) connectors on the CSM module.
Icon Colors
The colors of the icons on the cross connections screen can be used to quickly determine the current
state of the source and destination.
The icon colors are defined as follows:
• White icon indicates the ports are enabled but are not currently cross connected.
• Blue icon on RADIO and PDH (P32E1DS1/P2E3DS3) ports indicates the ports are
disabled or fully cross connected.
• Blue icon on ETH (Ethernet) ports indicates the ports are disabled.
• Green icon indicates that the ports are cross connected.
RADIO PORTS
MOD300
CARD(S)
PDH PORTS
P32E1DS1 /
P2E3DS3
CARDS
ETH PORTS
Ethernet
Connectors on
CSM CARDS
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 157/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-105
DLP-112
Line Colors
The drag and drop line, the operator inserts, between icons indicates an electrical connection. The
color of the line indicates type of data and direction.
The icon colors are defined as follows:
• Black Line - PDH (P32E1DS1/P2E3DS3) to RADIO (MD300)
• Blue Line - PDH (P32E1DS1/P2E3DS3) to ETH (Ethernet)
• Red Line - RADIO (MD300) to RADIO (MD300)
• Green Line - RADIO (MD300) to ETH (Ethernet)
Figure 112-3. Cross Connection: Line Color Detail
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 158/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-106
DLP-112
STEP PROCEDURE
1 CAUTION: Possibility of service interruption. Entering DS1 cross-connections while
the spare CSM card is Active may affect existing DS1 cross-connections. To preventthis from occurring, ONLY provision DS1 cross-connections while the main CSM is
Active.
2 Select Configuration/Cross Connections.
The Cross Connections window opens. See Figure 112-4.
3 Select Action?
If PDH to Radio (TDM2ETH), then go to step 4.
If PDH to Ethernet (TDM2ETH), then go to step 16.
Figure 112-4. Configuration Cross Connection Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 159/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-107
DLP-112
If Ethernet to Radio (TDM2ETH), then go to step 27.
If Radio to Radio, then go to step 36.
Provision PDH to Radio Cross Connection
4 Is the system configured with protected CSM cards?
If yes, go to step 5.
If no, go to step 9.
5 CAUTION: Possibility of service interruption. In the protected CSM configuration,
entering DS1 cross-connections while the spare CSM is Active may affect existing
DS1 cross-connections. To prevent this from occurring, ONLY provision DS1
cross-connections while the main CSM is Active.
6 Select Protection Schemes tab.
7 Verify the main CSM card is in the Active state.
8 Is the main CSM card in the Active state?
If yes, go to step 9.
If no, determine the reason the main CSM card is in the Standby state
and correct the condition prior to continuing with this procedure.
9 On the Cross Connection window, select PDH port and drag and draw line to RADIO.
PDH-RADIO pop-up displays. See Figure 112-5.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 160/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-108
DLP-112
10 On the PDH_RADIO pop-up, select check box for all Flow ID numbers to be cross
connected.
11 On the PDH_RADIO pop-up, click OK.
12 On the Cross Connection screen, click Apply.
13 From the Connections tab, verify the PDH_RADIO cross-connection was entered
correctly.
14 Go to step 42.
Figure 112-5. PDH-RADIO Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 161/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-109
DLP-112
Provision PDH to Ethernet Cross Connection
15 Is the system configured with protected CSM cards?
If yes, go to step 16.
If no, go to step 20.
16 CAUTION: Possibility of service interruption. In the protected CSM configuration,
entering DS1 cross-connections while the spare CSM is Active may affect existing
DS1 cross-connections. To prevent this from occurring, ONLY provision DS1
cross-connections while the main CSM is Active.
17 Select Protection Schemes tab.
18 Verify the main CSM card is in the Active state.
19 Is the main CSM card in the Active state?
If yes, go to step 20.
If no, determine the reason the main CSM card is in the Standby state
and correct the condition prior to continuing with this procedure.
20 On the Cross Connection window, select PDH port and drag and draw line to ETH
port.
PDH-ETH pop-up displays. See Figure 112-6.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 162/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-110
DLP-112
21 On the PDH-Eth pop-up, select Flow ID number from Flow ID drop-down list.
22 Enter the destination MAC address where the PDH will be terminated in the MAC
Address field.
NOTE: The first two digits of the destination MAC address for unprotected
ports must be set to ‘unicast’ or ‘00’. The first two digits of the destination MAC
address for 1+1 protected ports must be set to ‘multicast’ or ‘01’.
23 On the PDH-ETH pop-up, click OK.
24 On the Cross Connection screen, click Apply.
25 From the Connections tab, verify the PDH-ETH cross-connection was entered
correctly.
Figure 112-6. PDH to Ethernet Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 163/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-111
DLP-112
26 Go to step 42.
Provision Ethernet to Radio Cross Connection
27 Select ETH port and drag and draw line to Radio port.
RADIO-ETH pop-up displays. See Figure 112-7.
28 On the RADIO-ETH pop-up, enter Flow ID number in the Flow ID field.
NOTE: Ranging is supported for RADIO-ETH Cross-Connection entry.
29 Select TDM2TDM or TDM2ETH in the Profile drop-down menu.
30 Select ADAPTIVE or DIFFERENTIAL in the TDM Clock Source drop-down menu.
Figure 112-7. Ethernet to Radio Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 164/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-112
DLP-112
31 Enter the destination MAC address where the RADIO will be terminated in the MAC
Address field.
NOTE: The first two digits of the destination MAC address for unprotected
ports must be set to ‘unicast’ or ‘00’. The first two digits of the destination MAC
address for 1+1 protected ports must be set to ‘multicast’ or ‘01’.
32 On the RADIO-ETH pop-up, click OK.
33 On the Cross Connection screen, click Apply.
34 From the Connections tab, verify the RADIO-ETH cross-connection(s) were entered
correctly.
35 Go to step 42.
Provision Radio to Radio Cross Connection
36 Select Radio port and drag and draw line to Radio port.
RADIO-RADIO pop-up displays. See Figure 112-8.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 165/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections 4-113
DLP-112
37 On the RADIO-RADIO pop-up, enter Flow ID number for the far-end in the Flow ID
field.
NOTE: Ranging is supported for RADIO-RADIO Cross-Connection entry.
38 Select TDM2TDM or TDM2ETH in the Profile drop-down menu.
39 On the RADIO-RADIO pop-up, click OK.
40 On the Cross Connection screen, click Apply.
41 From the Connections tab, verify the RADIO-RADIO cross-connection(s) were entered
correctly.
42 STOP. This procedure is complete.
Figure 112-8. Radio to Radio Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 166/314
3EM23954ABIssue 01, February 2010
Provision Cross Connections4-114
DLP-112
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 167/314
3EM23954ABIssue 01, February 2010
View Alarms 4-115
DLP-113
DLP-113
View Alarms
PURPOSE
This procedure provides instructions to view alarms for the 9500 MPR.
GENERAL
The 9500 MPR Alarm Monitor allows the user to view current alarms and a log of alarm activity.
Both the current alarms and the alarm logs may be sorted by alarm severity. The following is a list
of alarm filtering available:
• CURRENT ALARMS:
– Global
– Critical (CRI)
– Major (MAJ)
– Minor (MIN)
– Warning (WRG)
– Indicator (IND)
• ALARM LOG: Global
– Global
– Critical (CRI)
– Major (MAJ)
– Minor (MIN)
– Warning (WRG)
– Indicator (IND)
– Cleared (CLR)
STEP PROCEDURE
View NE Alarms
1 Select Diagnosis/Alarms/NE Alarms. See Figure 113-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 168/314
3EM23954ABIssue 01, February 2010
View Alarms4-116
DLP-113
The Alarm Monitor window opens. See Figure 113-2.
The Alarm Monitor allows the user to view alarms by severity.
Figure 113-1. View NE Alarms Path
Figure 113-2. Alarm Monitor Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 169/314
3EM23954ABIssue 01, February 2010
View Alarms 4-117
DLP-113
2 Select CURRENT_ALARMS: MAJ from the Alarm Manager resource tree area.
The Synthesis pane displays the CURRENT_ALARMS: MAJ tab. See Figure 113-3.
3 STOP. This procedure is complete.
Figure 113-3. Alarm Manager: Current Alarms Major Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 170/314
3EM23954ABIssue 01, February 2010
View Alarms4-118
DLP-113
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 171/314
3EM23954ABIssue 01, February 2010
View Abnormal Condition List 4-119
DLP-114
DLP-114
View Abnormal Condition List
PURPOSE
This procedure provides instructions to view abnormal condition list for the 9500 MPR.
GENERAL
This abnormal condition list is a read-only screen that lists non-usual conditions present in the NE. Eventsthat cause an abnormal condition:
• Forced switch (EPS, RPS, TPS)
• Lockout (EPS, RPS, TPS)
•
Loopback activation
• Local radio Tx mute (manual)
• Local radio Tx mute (automatic)
• Remote radio Tx mute (manual)
STEP PROCEDURE
1 Select Diagnosis/Abnormal Condition List.
The Abnormal Condition List window opens.
Figure 114-1. Abnormal Condition List Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 172/314
3EM23954ABIssue 01, February 2010
View Abnormal Condition List4-120
DLP-114
2 Click Close.
3 STOP. This procedure is complete.
Figure 114-2. Abnormal Condition List Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 173/314
3EM23954ABIssue 01, February 2010
View Protection Schemes 4-121
DLP-115
DLP-115
View Protection Schemes
PURPOSE
This procedure provides instructions to view Protection Schemes for the 9500 MPR.
STEP PROCEDURE
1 Select Protection Schemes Tab.
The Protection Schemes tab opens. See Figure 115-1.
All the protection schemes provisioned for the 9500 MPR radio are displayed in the
main window pane.
2 Expand Protection Schemes in the Resource Tree area. See Figure 115-2.
Figure 115-1. Protection Schemes Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 174/314
3EM23954ABIssue 01, February 2010
View Protection Schemes4-122
DLP-115
3 Select action?
To view CSM protection scheme parameters, go to step 4.To view Synchronization protection schemes, go to step 6.
To view Equipment protection schemes, go to step 8
To view Equipment protection schemes, go to step 10
To view HSB protection schemes, go to step 12.
To view Rx Radio protection schemes, go to step 14
View CSM Protection Scheme Parameters
4 Select Protection Schemes/Slot#1-2/Equipment Protection in the Resource Tree area.
The Protection Schemes Parameter tab displays CSM protection scheme parameters
in the main window. See Figure 115-3.
Figure 115-2. Protection Schemes Resource Tree Expanded
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 175/314
3EM23954ABIssue 01, February 2010
View Protection Schemes 4-123
DLP-115
5 Go to step 15.
View Synchronization Protection Scheme Parameters
6 Select Protection Schemes/Synchronization Protection in the Resource Tree area.
The synchronization Protection Schemes Parameter tab displays in the main window.
See Figure 115-4.
Figure 115-3. CSM Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 176/314
3EM23954ABIssue 01, February 2010
View Protection Schemes4-124
DLP-115
7 Go to step 15.
View Radio Channel Protection Schemes Parameters
8 Select Protection Schemes/Radio channel (Dir#x.y) in the Resource Tree area.
The Protection Scheme Parameters tab displays in the main window. See
Figure 115-5.
Figure 115-4. Synchronization Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 177/314
3EM23954ABIssue 01, February 2010
View Protection Schemes 4-125
DLP-115
9 Go to step 15.
View Equipment Protection Schemes Parameters
10 Select Protection Schemes/Equipment Protection in the Resource Tree area.
The Protection Scheme Parameters tab displays in the main window. See
Figure 115-6.
Figure 115-5. Radio Channel Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 178/314
3EM23954ABIssue 01, February 2010
View Protection Schemes4-126
DLP-115
11 Go to step 15.
View Hot StandBy Protection Schemes Parameters
12 Select Protection Schemes/HSB Protection in the Resource Tree area.
The HSB Protection Scheme Parameters tab displays in the main window. See
Figure 115-7.
Figure 115-6. Equipment Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 179/314
3EM23954ABIssue 01, February 2010
View Protection Schemes 4-127
DLP-115
13 Go to step 15.
View Rx Radio Protection Schemes Parameters
14 Select Protection Schemes/Rx Radio Protection in the Resource Tree area.
The Rx Radio Protection Scheme Parameters tab displays in the main window. See
Figure 115-8.
Figure 115-7. HSB Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 180/314
3EM23954ABIssue 01, February 2010
View Protection Schemes4-128
DLP-115
15 STOP. This procedure is complete.
Figure 115-8. Rx Radio Protection Scheme Parameter Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 181/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data 4-129
DLP-116
DLP-116
Download Provisioning Data
PURPOSE
This procedure is used to download provisioning data for the radio.
GENERAL
Report file NEReport.txt is created automatically by radio software and available on the web for
downloading. The report can be opened using the standard web browser and entering into the field
the Radio IP Address or the rack name. The report is password protected.
STEP PROCEDURE
1 Select action?
If download provisioning data using JUSM/CT 9500MPR-A, go to
step 2.
If download provisioning data using web browser, go to step 14.
Download Provisioning Data Using JUSM/CT 9500MPR-A
2 Select Diagnosis/Current Configuration View. See Figure 116-1.
The Current Configuration View window opens. See Figure 116-2.
Figure 116-1. Diagnosis / Current Configuration View Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 182/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data4-130
DLP-116
3 Select action?
If save Current Configuration data, go to step 4.
If print Current Configuration data, go to step 9.
Save Current Configuration Data
4 Select File/Save As.
5 Navigate to the directory to save 9500MPR Current Configuration View file.
6 Click Save.
7 Select File/Exit.
8 Go to step 20.
Print Current Configuration Data
9 Select File/Print.
Figure 116-2. Diagnosis / Current Configuration View Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 183/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data 4-131
DLP-116
10 Select Printer to print 9500MPR provisioning verification file.
11 Click OK.
12 Select File/Exit.
13 Go to step 20.
Download Provisioning Data Using Web Browser
14 In a web browser, type in the radio IP address or the URL (shown below):
http://radio IP Address
9500MPR Web Server login screen displays.
15 Enter NE User ID and Password (same as user ID and password entered on CT).
The 9500MPR Web Server displays.
Figure 116-3. Provision Verification: Web Browser
Figure 116-4. Provision Verification: Login Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 184/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data4-132
DLP-116
16 On Main menu, select Configuration Info.
The File Download screen displays.
Figure 116-5. 9500MPR Web Server Main Page
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 185/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data 4-133
DLP-116
The File Download screen displays.
17 Click Save.
18 Navigate to the directory to save 9500MPR Current Configuration data.
19 Click Save.
Configuration file output, example of the start of the file:
**********************
* CONFIGURATION INFO *
**********************
Site Name: PLM 9500-165
Site Location: SVT Lab
QoS: Diff Serv
Bridge Address: 0:0:0:0:1:65
Fans: equipped
CORE CONFIGURATION
==================
Type: MSS-8, Enhanced, Protected
ETHERNET PORT
-------------
** Ep 1 **
Disabled
Figure 116-6. Configuration Info File Download Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 186/314
3EM23954ABIssue 01, February 2010
Download Provisioning Data4-134
DLP-116
Click
** Ep 2 **
Disabled
** Ep 3 **
Disabled
** Ep 4 **
Transport mode
Disabled
** Ep 5 **
Auto Negotiation: Enabled
BitRate: 1000 Mbit/s
Capability: Full Duplex
Flow Control: Disable
SLOTS CONFIGURATION
===================
** Slot 3 EAS **
ETHERNET PORT
-------------
** Ep 1 **
Auto Negotiation: Disabled
BitRate: 100 Mbit/s
Capability: Full Duplex
Flow Control: Disable
** Ep 2 **
Auto Negotiation: Enabled
BitRate:
10 Full Duplex
100 Full Duplex
1000 Full Duplex
Flow Control: Enable
*****************************
* END OF CONFIGURATION INFO *
*****************************
20 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 187/314
3EM23954ABIssue 01, February 2010
Administer System Settings 4-135
DLP-117
DLP-117
Administer System Settings
PURPOSE
This procedure is used to administer system settings.
GENERAL
The Systems Settings/NE Configuration screen is used to configure the Quality of Service (QoS) type,
enable DHCP Server support, enable event and alarm logging, and retrieve NE MAC Address/Bridge
Address.
The QoS Classification determines the Ethernet flow that will be transmitted from the CSM (Control
and Switching Module) to the MOD300 in the event of a fade. Typically the high priority traffic
experiences less delay in the CSM switch than the lower priority traffic.
Three QoS settings are available as follows:
• Disabled
• 802.1
• DiffServ
802.1p
When 802.1p is selected, the packet is examined for the presence of a valid 802.1p user-priority tag.
If the tag is present, priorities are set based on IEEE 802.1D-2004 Annex G User Priorities and
Traffic Classes that defines seven traffic types and corresponding user priority values.
DiffServ
When DiffServ is selected, the DSCP field of the packet is examined for the presence of one of eight
tags, each identifying one of eight traffic types and corresponding user values
The eight traffic types and corresponding priorities 1- 8 (8 being the highest priority) follow:
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 188/314
3EM23954ABIssue 01, February 2010
Administer System Settings4-136
DLP-117
DHCP Server Support
The default setting for DHCP server support is enabled. In most configurations this is the
recommended provisioning value.
When Port#4 TMN Ethernet Interface is connected to a larger TMN network, it is recommended to
disable DHCP server support to prevent duplicate IP address issues.
Event and Alarm log
To provision Event and alarm logging, select enabled in the Event and Alarm Log Logging field.
To record the NE MAC Address/Bridge Address, retrieve the value from the NE MAC
Address/Bridge Address field.
STEP PROCEDURE
1 Select Configuration/System Settings tab.
The System Settings tab opens. See Figure 117-1.
Table 117-A. DSCP Traffic Types
PRIORITY TRAFFIC TYPE DESCRIPTION
8 (Highest Priority) TDM2TDM (Always Highest
Priority)
7 TDM2ETH and TMN
6 ETH2ETH
5 Network Control and Voice VoIP, Video conferencing,
Audio conferencing
4 Video
3 Controlled Load Broadcast (Audio/Video)
2 Best Effort Web Browsing, Chat, Games
1 (Lowest Priority) Background E-mail, database download
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 189/314
3EM23954ABIssue 01, February 2010
Administer System Settings 4-137
DLP-117
2 Select action.
To set QoS Classification, go to step 3.
To set DHCP Server, go to step 7.
To set Event and Alarm Logging, go to step 11.To retrieve NE MAC Bridge Address, go to step 15.
Provision QoS Classification
3 From the QoS Classification drop-down menu, select the desired QoS Classification:
– Disabled
– 802.1
– DiffServ
4 Click Apply.
5 Click Close.
Figure 117-1. System Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 190/314
3EM23954ABIssue 01, February 2010
Administer System Settings4-138
DLP-117
6 Go to step 17.
Provision DHCP Server
7 From the DHCP Server drop-down menu, select the desired DHCP Server
provisioning:
– Disabled
– Enabled
8 Click Apply.
9 Click Close.
Figure 117-2. QoS Classification Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 191/314
3EM23954ABIssue 01, February 2010
Administer System Settings 4-139
DLP-117
10 Go to step 17.
Provision Event and Alarm Log
11 From the Logging drop-down menu, select the Event and Alarm Log provisioning:
– Disabled
– Enabled
12 Click Apply.
13 Click Close.
Figure 117-3. DHCP Server Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 192/314
3EM23954ABIssue 01, February 2010
Administer System Settings4-140
DLP-117
14 Go to step 17.
Retrieve NE MAC Address/Bridge Address
15 From the NE MAC Address/Bridge Address field, record the Bridge Address:
16 Click Close.
Figure 117-4. Event and Alarm Log Drop-Down Menu
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 193/314
3EM23954ABIssue 01, February 2010
Administer System Settings 4-141
DLP-117
17 STOP. This procedure is complete.
Figure 117-5. NE MAC Address / Bridge Address
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 194/314
3EM23954ABIssue 01, February 2010
Administer System Settings4-142
DLP-117
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 195/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration 4-143
DLP-118
DLP-118
Administer Network Configuration
PURPOSE
This procedure is used to administer network configuration.
GENERAL
TMN Ethernet port provisioning requirements depend on how the CSM Ethernet port 4 and NMS
port on the CSM card are to be used.
The NMS port is normally reserved for Craft Terminal interface with the PC. The serial data
interface with the PC for the Craft Terminal on the NMS port is default enabled with IP address
10.0.1.2 and requires no special provisioning. For NMS port provisioning other than the default
values, provision TMN Ethernet Interface.
If CSM Ethernet Port#4 is being used to interface external Ethernet equipment, then the Ethernet
Physical Interface Port#4 must be enabled and provisioned and Port#4 TMN Ethernet Interface
must be disabled.
If Port#4 TMN Ethernet interface is used to connect to a larger TMN network and communicate with
other equipment at the site. The Ethernet Physical Interface Port#4 must be disabled, Port#4 TMN
Ethernet Interface must be provisioned and TMN Ethernet Interface must be provisioned.
IP Provisioning is normally performed by the Internet Protocol (IP group). Before starting IP
provisioning, the user must know IP routing and have the following information available:
• IP Address
• IP Mask
• Method of IP routing to be used in network
• If OSPF (Open Shortest Path First protocol) is the required routing method, the
user must know the number of the OSPF Area the radio is in.
• TMN Ethernet Interface
STEP PROCEDURE
1 Select action.
To provision NE IP Address, go to step 2.
To administer TMN Ethernet Interface, go to step 7.
To administer TMN Port#4 Ethernet Interface, go to step 26.
To provision IP Static Routing, go to step 47.
To provision Provision OSPF Area, go to step 60.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 196/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration4-144
DLP-118
Provision IP Address of NE
2 Select Configuration/Network Configuration/Local Configuration.
The Local Configuration window opens.
3 Enter the <IP address> of the NE in the IP Address field.
4 Click Apply.
5 Click Close.
6 Go to step 67.
Administer TMN Ethernet Interface
7 Select the MSS/Core-Main slot #1 in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area.
8 Double left click the blue MSS/Core-Main (CSM) Card.
Figure 118-1. 9500 MPR NE IP Address Path
Figure 118-2. 9500 MPR NE IP Address
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 197/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration 4-145
DLP-118
Ethernet Physical Interface Settings Tab displays.
9 Select TMN Interface tab.
10 Select TMN Port in left frame.
11 Selecting Settings tab.
Figure 118-3. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 198/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration4-146
DLP-118
12 Select action.
To provision TMN Interface, go to step 13.
To deprovision TMN Interface, go to step 22.
Provision TMN Ethernet Interface
13 Select TMN Working Mode check box Enabled.
14 Enter IP Address in IP Address field.
15 Enter IP Mask or Netmask in IP Mask field.
16 Select IP Routing Protocol from drop-down menu.
– Static Routing.
– OSPF
Figure 118-4. TMN Ethernet Interface: Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 199/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration 4-147
DLP-118
17 OSPF IP Routing Protocol selected?
If yes, then go to step 18.
If no, go to step 19.
18 Select the OSPF Area Number from drop-down menu and select OSPF Area Number.
19 Click Apply.
20 Close slot #1 window.
21 Go to step 67.
Deprovision TMN Ethernet Interface
22 Select TMN Working Mode check box Enabled (unchecked).
23 Click Apply.
24 Close slot #1 window.
25 Go to step 67.
Administer Port#4 TMN Ethernet Interface
26 Select the MSS/Core-Main slot #1 in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area.
27 Double left click the blue MSS/Core-Main (CSM) Card.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 200/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration4-148
DLP-118
Ethernet Physical Interface Settings Tab displays.
28 Select TMN Interface tab.
29 Select Port#4 TMN Ethernet in left frame.
30 Selecting Settings tab.
31 Select action.
To provision Port#4 TMN Ethernet Interface, go to step 32.
To deprovision Port#4 TMN Ethernet Interface, go to step 43.
Figure 118-5. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 201/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration 4-149
DLP-118
Provision Port#4 TMN Ethernet Interface
Provision Port#4 TMN Ethernet Interface
32 Select TMN Working Mode Enabled check box.
33 Enter IP Address for Port#4 TMN Ethernet interface.
34 Enter IP Mask or Netmask.
35 Static or OSPF TMN interface routing?
If static, go to step 36.
If OSPF, go to step 38.
36 Select the IP Routing Protocol drop-down menu and select Static Routing.
Figure 118-6. Port#4 TMN Ethernet Interface: Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 202/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration4-150
DLP-118
37 Go to step 40.
38 Select the IP Routing Protocol drop-down menu and choose OSPF.
39 Select the OSPF Area Number drop-down menu and choose OSPF Area Number(0 - 3).
40 Click Apply.
41 Close the slot #1 window.
42 Go to step 67.
Deprovision Port#4 TMN Ethernet Interface
43 Select TMN Working Mode check box Enabled (unchecked).
44 Click Apply.
45 Close slot #1 window.
46 Go to step 67.
Provision IP Static Routing
47 Select Configuration/Network Configuration/IP Configuration/IP Static Routing
Configuration.
The IP Static Routing Configuration window opens.
48 Select the desired Host or Network Address Choice radio button:
– Host
– Network
49 Which IP Static Routing Configuration was selected?
If Network, go to step 50.
If Host, go to step 51.
50 Enter the IP Mask of the radio in the IP Mask text field.
51 Enter the IP Address of the radio in the IP Address text field.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 203/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration 4-151
DLP-118
52 Select the desired Default Gateway or Point to Point I/F Choice radio button:
– Default Gateway IP Address
– Point To Point Interface Index
53 Which Default Gateway or Point to Point I/F Choice was selected?
If Default Gateway IP Address, go to step 54.
If Point To Point Interface Index, go to step 56.
54 Enter the Default Gateway IP Address in the Default Gateway IP Address text field.
55 Go to step 57.
56 From the Interface Type drop-down menu, select Gateway.
57 Click Create.
58 Click Close.
59 Go to step 67.
Provision OSPF Area Configuration
60 Select Configuration/Network Configuration/IP Configuration/OSPF Area Configuration.
The OSPF Area Configuration window opens.
61 Select the new check-box.
62 Enter the OSPF Area Address in the OSPF Area Address text field.
Figure 118-7. OSPF Area Configuration Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 204/314
3EM23954ABIssue 01, February 2010
Administer Network Configuration4-152
DLP-118
63 Select the desired OSPF Area Stub Flag drop-down menu, select the desired OSPF
Area Stub Flag value:
– True
– False
64 Click Create.
65 Click Apply.
66 Click Close.
67 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 205/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time 4-153
DLP-119
DLP-119
Administer System Date and Time
PURPOSE
This procedure is used to administer NE Date and Time.
GENERAL
The system NE Time can be set to the operating system (PC/laptop) or manually, or to a Network
Time Protocol (NTP) server to manage time and date stamping functions. Time and date
provisioning is accomplished using the NE Time Configuration screen.
The date format is yyyy/mm/dd, where yyyy equals the four digit year, mm equals the two digit
month, and dd equals the two digit day.
The time format is hh:mm:ss, where hh equals the two digit hour (00 - 23), mm equals the two digitminute (00 - 59), ss equals the two digit second (00 - 59).
Following an NE time change, PM history data must be cleared to prevent reporting erroneous PM
data.
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
1 Select action?
If set NE Time with PC Operating System Time, go to step 2.
If set NE Time manually, go to step 2.
If set NE Time with NTP server, go to step 14.
2 Select the Configuration/NE Time.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 206/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time4-154
DLP-119
The NE Time Configuration window opens.
3 Select action?
If set NE Time with PC Operating System Time, go to step 4.
If set NE Time manually, go to step 9.
Set NE Time to PC Operating System Time
4 Select Set NE Time with OS Time check box.
Figure 119-1. NE Time Configuration Drop-Down Menu
Figure 119-2. NE Time Configuration Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 207/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time 4-155
DLP-119
5 Click Apply to save the changes.
The Information ‘Set NE time success!’ window opens.
6 Click OK .
7 Click Close.
8 Go to step 22.
Set NE Time Manually
9 Select the date and time element to set in the Network Element Time field and perform
one or more of the following:
a. Enter the four digit year yyyy.
b. Enter the two digit month mm.
c. Enter the two digit day dd.
d. Enter the two digit hour hh.
e. Enter the two digit minute mm.
f. Enter the two digit second ss.
10 Click Apply to save the changes.
The Information ‘Set NE time success!’ window opens.
11 Click OK .
12 Click Close.
13 Go to step 22.
Set NE Time with NTP Server
14 Select the Configuration/Network Configuration/NTP Configuration.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 208/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time4-156
DLP-119
15 The NTP Configuration window opens.
16 Select Enable check-box in the NTP Protocol field.
17 Enter Main Server address.
18 Enter Spare Server address if desired.
Figure 119-3. NTP Configuration Drop-Down Menu
Figure 119-4. NTP Configuration Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 209/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time 4-157
DLP-119
19 Click Apply.
The Information ‘Set NTP Server success!’ window opens.
20 Click OK .
21 Click Close.
22 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 210/314
3EM23954ABIssue 01, February 2010
Administer System Date and Time4-158
DLP-119
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 211/314
3EM23954ABIssue 01, February 2010
Administer Software License 4-159
DLP-120
DLP-120
Administer Software License
PURPOSE
This procedure provides the instructions to update and view Software License for the 9500 MPR.
STEP PROCEDURE
1 Select Supervision/SW License.
The SW License window opens.
Figure 120-1. Supervision SW License Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 212/314
3EM23954ABIssue 01, February 2010
Administer Software License4-160
DLP-120
2 Select action?
To view Software License, go to step 3.
To Update Software License, go to step 6.
View SW License
3 View software License Key, License String, and RMU Serial Number.
4 Click Close.
5 Go to step 11.
Update SW License
6 Open new software license text file.
7 Select new software License Key from text file and copy.
8 Select old software License Key in the SW License window and paste new software
License Key.
Figure 120-2. SW License Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 213/314
3EM23954ABIssue 01, February 2010
Administer Software License 4-161
DLP-120
9 Click Apply.
10 Click Close.
11 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 214/314
3EM23954ABIssue 01, February 2010
Administer Software License4-162
DLP-120
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 215/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-163
DLP-121
DLP-121
Perform Protection Switching
PURPOSE
This procedure provides the instructions to perform Protection Switching for the 9500 MPR.
CAUTION: Possibility of service interruption. Protection switching traffic will cause a hit to traffic.
STEP PROCEDURE
1 Select Protection Schemes Tab.
The Protection Schemes window opens. See Figure 121-1.
2 Select action?
To perform protection switching on CSM card, go to step 3.
To perform Equipment Protection switching, go to step 15.
Figure 121-1. Protection Schemes Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 216/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-164
DLP-121
To perform HSB Protection switching, go to step 39.
To perform Rx Radio Protection switching, go to step 63.
Protection Switching on CSM Card
3 Select action?
To perform Forced Switch from Main CSM card to Spare CSM card, go
to step 4.
To perform Lockout of Spare CSM card, go to step 10.
Forced Switch Main CSM to Spare CSM
4 Select Main CSM card in the Resource Tree area. See Figure 121-2.
5 On the Commands tab, select Forced in the New Value drop-down menu.
6 CAUTION: Possibility of service interruption. Forced switching CSM will cause a hit
to traffic.
7 Click Apply.
The Switch confirmation window displays.
8 Click OK .
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 217/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-165
DLP-121
9 Go to step 86.
Lockout Spare CSM Card
10 Select Spare CSM card in the Resource Tree area. See Figure 121-3.
11 On the Commands tab, select Lockout in the New Value drop-down menu.
12 Click Apply.
The Switch confirmation window displays.
13 Click OK .
Figure 121-2. Forced Switch Main CSM to Spare CSM
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 218/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-166
DLP-121
14 Go to step 86.
Equipment Protection
15 Select action?
To perform Forced Switch from Main to Spare, go to step 16.
To perform Manual Switch from Main to Spare, go to step 22.
To perform Manual Switch from Spare to Main, go to step 28.
To perform Lockout Switch of Spare, go to step 34.
16 Select Protection Schemes/Slot#/Equipment Protection/Main # in the Resource Tree
area. See Figure 121-4.
17 CAUTION: Possibility of service interruption. Forced EPS switching equipment will
cause a hit to traffic.
18 On the Commands tab, select Forced in the New Value drop-down menu.
19 Click Apply.
The Switch confirmation window displays.
Figure 121-3. Lockout Spare CSM Card
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 219/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-167
DLP-121
20 Click OK .
21 Go to step 86.
Equipment Protection: Manual Switch Main to Spare
22 Select Protection Schemes/Slot#/Equipment Protection/Main # in the Resource Tree
area. See Figure 121-5.
23 CAUTION: Possibility of service interruption. Manual EPS switching equipment will
cause a hit to traffic.
24 On the Commands tab, select Manual in the New Value drop-down menu.
25 Click Apply.
The Switch confirmation window displays.
26 Click OK .
Figure 121-4. Forced Equipment Switch Main to Spare
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 220/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-168
DLP-121
27 Go to step 86.
Equipment Protection: Manual Switch Spare to Main
28 Select Protection Schemes/Slot#/Equipment Protection/Main # in the Resource Tree
area. See Figure 121-6.
29 CAUTION: Possibility of service interruption. Manual EPS switching equipment will
cause a hit to traffic.
30 On the Commands tab, select Manual in the New Value drop-down menu.
31 Click Apply.
The Switch confirmation window displays.
32 Click OK .
Figure 121-5. Manual Equipment Switch: Main to Spare
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 221/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-169
DLP-121
33 Go to step 86.
Equipment Protection: Lockout Spare
34 Select Protection Schemes/Slot#/Equipment Protection/Main # in the Resource Tree
area. See Figure 121-7.
35 On the Commands tab, select Lockout in the New Value drop-down menu.
36 Click Apply.
The Switch confirmation window displays.
37 Click OK .
Figure 121-6. Manual Equipment Switch: Spare to Main
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 222/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-170
DLP-121
38 Go to step 86.
Hot StandBy Protection Switching
39 Select action?
To perform Forced Switch from Main to Spare, go to step 40.
To perform Manual Switch from Main to Spare, go to step 46.
To perform Manual Switch from Spare to Main, go to step 52.
To perform Lockout Switch of Spare, go to step 58.
HSB Protection: Forced Switch Main Radio Channel to Spare Radio Channel
40 Select Protection Schemes/Slot#/HSB Protection/Main # in the Resource Tree area.
See Figure 121-8.
41 CAUTION: Possibility of service interruption. Forced HSB switching equipment will
cause a hit to traffic.
42 On the Commands tab, select Forced in the New Value drop-down menu.
Figure 121-7. Lockout Equipment Switch: Lockout Switch to Spare
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 223/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-171
DLP-121
43 Click Apply.
The Switch confirmation window displays.
44 Click OK .
45 Go to step 86.
HSB Protection: Manual Switch Main Radio Channel to Spare Radio Channel
46 Select Protection Schemes/Slot#/HSB Protection/Main # in the Resource Tree area.
See Figure 121-9.
47 CAUTION: Possibility of service interruption. Manual HSB switching equipment willcause a hit to traffic.
48 On the Commands tab, select Manual in the New Value drop-down menu.
49 Click Apply.
The Switch confirmation window displays.
Figure 121-8. Forced HSB Switch Main Radio Channel to Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 224/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-172
DLP-121
50 Click OK .
51 Go to step 86.
HSB Protection: Manual Switch Spare Radio Channel to Main Radio Channel
52 Select Protection Schemes/Slot#/HSB Protection/Spare # in the Resource Tree area.
See Figure 121-10.
53 CAUTION: Possibility of service interruption. Manual HSB switching equipment will
cause a hit to traffic.
54 On the Commands tab, select Manual in the New Value drop-down menu.
55 Click Apply.
The Switch confirmation window displays.
56 Click OK .
Figure 121-9. Manual HSB Switch: Main Radio Channel to Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 225/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-173
DLP-121
57 Go to step 86.
HSB Protection: Lockout Spare Radio Channel
58 Select Protection Schemes/Slot#/HSB Protection/Spare # in the Resource Tree area.
See Figure 121-11.
59 On the Commands tab, select Lockout in the New Value drop-down menu.
60 Click Apply.
The Switch confirmation window displays.
61 Click OK .
Figure 121-10. Manual HSB Switch: Spare Radio Channel to Main Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 226/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-174
DLP-121
62 Go to step 86.
Rx Radio Protection Switching
63 Select action?
To perform Forced Switch from Main to Spare, go to step 64.
To perform Manual Switch from Main to Spare, go to step 70.
To perform Manual Switch from Spare to Main, go to step 76.
To perform Lockout Switch of Spare, go to step 82.
Rx Radio Protection: Forced Switch Main Radio Channel to Spare Radio Channel
64 Select Protection Schemes/Slot#/Rx Radio Protection/Main # in the Resource Tree
area. See Figure 121-12.
65 CAUTION: Possibility of service interruption. Forced Rx Radio switching equipment
will cause a hit to traffic.
66 On the Commands tab, select Forced in the New Value drop-down menu.
Figure 121-11. Lockout HSB Switch: Lockout Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 227/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-175
DLP-121
67 Click Apply.
The Switch confirmation window displays.
68 Click OK .
69 Go to step 86.
Rx Radio Protection: Manual Switch Main Radio Channel to Spare Radio Channel
70 Select Protection Schemes/Slot#/Rx Radio Protection/Main # in the Resource Tree
area. See Figure 121-13.
71 CAUTION: Possibility of service interruption. Manual Rx Radio switching equipmentwill cause a hit to traffic.
72 On the Commands tab, select Manual in the New Value drop-down menu.
73 Click Apply.
The Switch confirmation window displays.
Figure 121-12. Forced Rx Radio Switch: Main Radio Channel to Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 228/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-176
DLP-121
74 Click OK .
75 Go to step 86.
Rx Radio Protection: Manual Switch Spare Radio Channel to Main Radio Channel
76 Select Protection Schemes/Slot#/Rx Radio Protection/Spare # in the Resource Tree
area. See Figure 121-14.
77 CAUTION: Possibility of service interruption. Manual Rx Radio switching equipment
will cause a hit to traffic.
78 On the Commands tab, select Manual in the New Value drop-down menu.
79 Click Apply.
The Switch confirmation window displays.
80 Click OK .
Figure 121-13. Manual Rx Radio Switch: Main Radio Channel to Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 229/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching 4-177
DLP-121
81 Go to step 86.
Rx Radio Protection: Lockout Spare Radio Channel
82 Select Protection Schemes/Slot#/Rx Radio Protection/Spare # in the Resource Tree
area. See Figure 121-15.
83 On the Commands tab, select Lockout in the New Value drop-down menu.
84 Click Apply.
The Switch confirmation window displays.
85 Click OK .
Figure 121-14. Manual Rx Radio Switch: Spare Radio Channel to Main Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 230/314
3EM23954ABIssue 01, February 2010
Perform Protection Switching4-178
DLP-121
86 STOP. This procedure is complete.
Figure 121-15. Lockout Rx Radio Switch Spare Radio Channel
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 231/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-179
DLP-122
DLP-122
Performance Monitoring
PURPOSE
This procedure provides the instructions to configure and perform Performance Monitoring (PM) for
the 9500 MPR.
GENERAL
PM provides an indication of the quality of service for the Radio Hop Section and Link Hop Section.
Radio Hop Section and Link Hop Section are defined as follows:
• Radio Hop Section—An unprotected radio channel (before Radio Protection
Switching in 1+1 radio configurations).
• Link Hop Section—A protected radio channel (after Radio Protection Switching).Only supported in 1+1 radio configurations.
Adaptive Modulation PM captures the modulation scheme used on the Tx side when adaptive
modulation is enabled. In 1+1 HSB radio configuration, the statistics are associated with the link
level after Radio Protection Switching. Adaptive Modulation PM is not supported in 1+1 FD radio
configurations.
Defect second for a radio hop section is a second with a LOF of DemFail occurrence.
Defect second for a Link hop section is a second with a LOF at the link level after Radio Protection
Switching.
Errored Block count for a radio hop section equals the number of errored block.
Errored Block count for a Link hop section equals the number of errored block at the link level after
Radio Protection Switching.
Four PM counters are supported as follows:
• Errored Second (ES)—When a defect second is set or if there is at least one or more
errored blocks.
• Severely Errored Seconds (SES)—When a defect second is set and if the errored
block count is greater or equal to 30% of the blocks in one second.
• Background Block Error (BBE))—The number of block errors in a one second
period and the second is not a SES.
• Unavailable Seconds (UAS)—A time period starting after ten consecutive SES
events are detected. The qualifying 10 consecutive SES seconds are included in
the UAS time period. Ending upon the detection of 10 consecutive non SES events.
These non SES seconds are not included in the UAS time period.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 232/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-180
DLP-122
PM data is collected for 15 minute and 24 hour time periods. One current register and ninety-six
history reports are available for 15 minute period. One current register and eight history reports are
available for 24 hour time period.
PM data is considered suspect when one or more of the following conditions occurs during the
collection period.
• The elapsed time deviates more than 10/900 seconds of the nominal time for 15
minute and 24 hour collection period.
• Loss of PM data in equipment
• Performance counters were reset during collection period.
• PM was activated during the collection period.
The 15 minute PM data is stored in the History Data report only when errors are recorded.
The 24 hour PM data is always stored in the History Data report.
Threshold Crossing Alarm (TCA) thresholds are provisionable from the PM window. Two default
TCA threshold data tables are provided. One for 15 minute TCAs and one for 24 hour TCAs. Two
additional TCA threshold data tables are provisionable for both 15 minute TCAs and 24 hour TCAs.
See figure 122-A for default TCA thresholds values.
Following an NE time change, PM history data must be cleared to prevent reporting erroneous PM
history data.
STEP PROCEDURE
1 Double left click the blue MSS/Radio (MOD300) Card.
Table 122-A. Default TCA Threshold Alarm Values
TCA ALARM 15 MINUTE
LOW
15 MINUTE
HIGH
24 HOUR
LOW
15 MINUTE
HIGH
BBE 200 9000 0 48000
ES 20 180 0 1500
ESE 0 15 0 20
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 233/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-181
DLP-122
MSS Radio Main View window opens.
2 Select Performance Monitoring Tab.
MSS Radio Performance Monitoring Tab displays.
Figure 122-1. 9500 MPR Equipment Tab: MOD300 Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 234/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-182
DLP-122
3 Select action?
To create new TCA thresholds table, go to step 4.
To modify existing TCA threshold table values, go to step 11.
To delete existing TCA threshold table, go to step 15.
To start PM, go to step 18.
To view PM data, go to step 28.
To export PM history data, go to step 31.
Create New TCA Threshold Table
4 In the Resource Tree Area, select either Threshold Table HOP or Threshold Table
LINK .
Figure 122-2. Performance Monitoring Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 235/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-183
DLP-122
5 In the Resource List Area, select either 15m (15 minute) or 24h (24 hour) radio button.
6 Enter the values for BBE (low and high).
7 Enter the values for ES (low and high).
8 Enter the values for SES (low and high).
9 Click Create.
Figure 122-3. Threshold Data Creation Pane
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 236/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-184
DLP-122
10 Go to step 37.
Modify Existing TCA Threshold Table Values
11 In the Resource Tree Area, select existing Threshold #n to modify TCA threshold
values.
NOTE: Threshold Table HOP, Threshold #1 and #4 are default tables. Threshold Table LINK,
Threshold #1 and #3 are default tables. The default table values are not editable.
Figure 122-4. Threshold #2 Data Table Created
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 237/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-185
DLP-122
12 Enter the new value(s) for BBE (low and high), ES (low and high), and/or SES (low and
high).
13 Click Apply.
Figure 122-5. Threshold Data Table Selected for Modification
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 238/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-186
DLP-122
14 Go to step 37.
Delete Existing TCA Threshold Table
15 In the Resource Tree Area, select existing Threshold #n to delete.
Figure 122-6. Threshold Data Table Modified
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 239/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 240/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-188
DLP-122
17 Go to step 37.
Start Performance Monitoring
18 In the Resource Tree Area, select desired HOP - Channel #n or LINK .
Figure 122-8. Threshold Data Table Deleted
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 241/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-189
DLP-122
19 In the Resource List Area, select Counter Thresholds for 15m (15 minutes).
20 Click Apply.
21 In the Resource List Area, select Counter Thresholds 24h (24 hour).
22 Click Apply.
23 In the Resource Tree Area, select HOP - Channel #n CD 15m or LINK CD 15m.
24 Click Start.
25 In the Resource Tree Area, select HOP - Channel #n CD 24h or LINK CD 24h.
26 Click Start.
Figure 122-9. PM HOP - Channel #0 Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 242/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-190
DLP-122
27 Go to step 37.
View Performance Monitoring Data
28 In the Resource Tree Area, select HOP - Channel #n or LINK CD/HD 15m/24h to
view PM data.
Figure 122-10. PM HOP-Channel #0 Current Data 15 Minute Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 243/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-191
DLP-122
29 Click Refresh.
Figure 122-11. PM Data HOP-Channel #0 Current Data 15 Minute Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 244/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-192
DLP-122
30 Go to step 37.
Export Performance Monitoring History Data
31 In the Resource Tree Area, select HOP - Channel #n or LINK HD 15m/24h to export
PM data.
Figure 122-12. PM Data HOP-Channel #1 History Data 15 Minute Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 245/314
3EM23954ABIssue 01, February 2010
Performance Monitoring 4-193
DLP-122
32 Click Export.
The Save dialog box opens.
33 Navigate to the directory to save PM History Data.
34 Enter the File Name to save PM History Data.
35 Click Save.
The Message dialog box opens.
36 Click OK.
37 STOP. This procedure is complete..
Figure 122-13. PM Data HOP-Channel #1 History Data 15 Minute Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 246/314
3EM23954ABIssue 01, February 2010
Performance Monitoring4-194
DLP-122
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 247/314
3EM23954ABIssue 01, February 2010
Perform Radio Power Measurements 4-195
DLP-123
DLP-123
Perform Radio Power Measurements
PURPOSE
This procedure provides the instructions to perform Radio Power Measurements for the 9500 MPR.
STEP PROCEDURE
1 In the main equipment window, double left click the MOD300 card to perform radio
power measurements. See Figure 123-1.
The main view for the selected radio direction opens.
2 Select Measurements tab. See Figure 123-2.
3 Select Channel # to perform power measurements.
Figure 123-1. Main Equipment Window: MOD300 Card Highlighted
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 248/314
3EM23954ABIssue 01, February 2010
Perform Radio Power Measurements4-196
DLP-123
4 Enter the Measurement Interval.
5 From the Sample Time (sec) drop-down menu, select the sample time.
6 Click Start.
The radio power measurement graphical view opens. See figure 123-3.
The radio power measurement tabular view opens. See figure 123-4.
Figure 123-2. Radio Power Measurement Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 249/314
3EM23954ABIssue 01, February 2010
Perform Radio Power Measurements 4-197
DLP-123
Figure 123-3. Radio Power Measurement: Graphical View
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 250/314
3EM23954ABIssue 01, February 2010
Perform Radio Power Measurements4-198
DLP-123
7 Click Close.
8 STOP. This procedure is complete.
Figure 123-4. Radio Power Measurement: Tabular View
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 251/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections 4-199
DLP-126
DLP-126
Deprovision Cross Connections
PURPOSE
This procedure is used to deprovision cross connections.
GENERAL
STEP PROCEDURE
1 Select Configuration/Cross Connections.
The Cross Connections window opens. See figure 126-1.
Figure 126-1. Cross Connection Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 252/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections4-200
DLP-126
2 Select Action?
If PDH to Radio (TDM2ETH), then go to step 3.
If PDH to Ethernet (TDM2ETH), then go to step 8.
If Ethernet to Radio (TDM2ETH), then go to step 13.
If Radio to Radio, then go to step 18.
Deprovision PDH to Radio Cross Connect
3 Double left-click PDH to RADIO line.
PDH-RADIO pop-up displays. See figure 126-2.
4 On the PDH_RADIO pop-up, select check box (unchecked) all Flow ID numbers of
cross connects to be deprovisioned.
5 On the PDH_RADIO pop-up, click OK.
6 On the Cross Connection screen, click Apply.
Figure 126-2. PDH-RADIO Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 253/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections 4-201
DLP-126
7 Go to step 22.
Deprovision PDH to Ethernet Cross Connection
8 Double left-click PDH port to Eth port line.
PDH-Eth pop-up displays. See figure 126-3.
9 On the PDH-Eth pop-up, select check box (unchecked) all Flow ID numbers of cross
connects to be deprovisioned.
10 On the PDH-ETH pop-up, click OK.
11 On the Cross Connection screen, click Apply.
12 Go to step 22.
Figure 126-3. PDH to Ethernet Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 254/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections4-202
DLP-126
Deprovision Ethernet to Radio Cross Connection
13 Double left-click ETH port to Radio port line.
RADIO-ETH pop-up displays. See figure 126-4.
14 On the RADIO-ETH pop-up, select check box (unchecked) Flow ID number of cross
connect to be deprovisioned.
15 On the RADIO-ETH pop-up, click OK.
16 On the Cross Connection screen, click Apply.
17 Go to step 22.
Figure 126-4. Ethernet to Radio Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 255/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections 4-203
DLP-126
Deprovision Radio to Radio Cross Connection
18 Double left-click Radio port to Radio port line.
RADIO-RADIO pop-up displays. See figure 126-5.
19 On the RADIO-RADIO pop-up, select check box (unchecked) Flow ID number of cross
connect to be deprovisioned.
20 On the RADIO-RADIO pop-up, click OK.
21 On the Cross Connection screen, click Apply.
22 STOP. This procedure is complete.
Figure 126-5. Radio to Radio Cross Connection
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 256/314
3EM23954ABIssue 01, February 2010
Deprovision Cross Connections4-204
DLP-126
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 257/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports 4-205
DLP-127
DLP-127
Deprovision Ethernet Ports
PURPOSE
This procedure is used to deprovision Ethernet ports.
STEP PROCEDURE
1 Select action.
To deprovision CSM 10/100/1000 BaseT Ethernet Interfaces, go to
step 2.
To deprovision CSM Ethernet SFP Interface, go to step 11.
Deprovision Physical CSM Ethernet Interfaces
10/100/1000 Base T Ethernet Interfaces
2 Select the MSS/Core-Main slot #1 in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area. See figure 127-1.
3 Double left click the blue MSS/Core-Main (CSM) Card and the Settings Tab for the
Ethernet Physical Interface will display.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 258/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports4-206
DLP-127
Ethernet Physical Interface Tab will display.
4 Select Ethernet Physical Interface tab.
5 Select Ethernet Port number to deprovision (Ethernet Port #1/#4 ).
6 Selecting Settings tab. See figure 127-2.
Figure 127-1. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 259/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports 4-207
DLP-127
7 Enable Port Status, select enabled [unchecked].
8 Click Port Status Apply.
9 Close slot #1 window.
10 Go to step 19.
Deprovision CSM Ethernet SFP Interface
11 Select the MSS/Core-Main slot #1 in the Resource Tree area. The selected name will be
highlighted in yellow. This selection should also highlight the MSS/Core card in blue
Resource List Area. See figure 127-3.
Figure 127-2. CSM Ethernet Physical Interface: Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 260/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports4-208
DLP-127
12 Double left click the blue MSS/Core-Main (CSM) Card.
Ethernet Physical Interface Settings Tab will display. See figure 127-4.
Figure 127-3. 9500 MPR Equipment Tab: CSM Card Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 261/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports 4-209
DLP-127
13 Select Ethernet Physical Interface tab.
14 Select Ethernet Port number #5 .
15 Selecting Settings tab. See figure 127-4.
16 Enable Port Status, select Enabled [unchecked].
17 Click Port Status Apply.
18 Go to step 19.
19 STOP. This procedure is complete.
Figure 127-4. CSM Ethernet Physical Interface: SFP Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 262/314
3EM23954ABIssue 01, February 2010
Deprovision Ethernet Ports4-210
DLP-127
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 263/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-211
DLP-128
DLP-128
Administer NE Lists
PURPOSE
This procedure provides instructions to create an NE list, add NEs to the NE list, and how to log into
an NE using the NE list.
PREREQUISITE
The Username and current Password must be known before login can be accomplished. 9500 MPR-A
CT R01.02 - Craft Terminal (CT) software must be installed on the PC. The user must know the IP
address of the NE to log into the system or be locally connected.
GENERAL
The 9500 MPR provides support for the Craft Terminal (CT) or WebEML (JUSM/CT) function,allowing NE management through a web-enabled PC.
The NE is accessed using the Network ElemenT Overview (NETO) application.
The WebEML Craft Terminal Reference Guide in the back of this manual may also be used as
reference.
STEP PROCEDURE
1 Select action?
If create new NE list, go to step 2.
If add NE to list, go to step 7.
If log into NE from list, go to step 20.
Create NE List
2 From the NETO login screen, select the Creates a new list of favorite NEs icon. See
Figure 128-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 264/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-212
DLP-128
The Network Element List window opens. See Figure 128-2.
3 Click Save.
The Save window opens. See Figure 128-3.
Figure 128-1. NETO Overview Window
Figure 128-2. Network Elements List Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 265/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-213
DLP-128
4 In the File Name field, type the desired name of the NE list: <NE_List_Name>
5 Click Save.
The Filed saved window opens.
6 Click OK.
The Network Elements List window opens. See Figure 128-4.
Figure 128-3. NE List Save Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 266/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-214
DLP-128
Add NE to List
7 Select action?
If add NE by first logging into the NE, go to step 8.
If add NE by entering NE IP address into Network Elements List
window, go to step 14.
Add NE to List by First Logging into the NE
8 From the NETO login window, log into the NE to add to the NE list.
9 From the Network Elements List window, click Get Current. See Figure 128-5.
The NE currently logged into is added to the NEs table.
Figure 128-4. Network Elements List Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 267/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-215
DLP-128
10 Click Save.
File already existing. Overwrite? window opens.
11 Click Yes.
File saved window opens.
12 Click OK.
13 Go to step 35.
Add NE to List by Entering NE IP Address
14 Click New. See Figure 128-6.
15 In the table row just added, type the NE IP address in the IP/DNS column and hit
Enter .
Figure 128-5. Network Elements List Window: Current NE Added
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 268/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-216
DLP-128
16 Click Save.
Save window opens.File already existing. Overwrite? window opens.
17 Click Yes.
File saved window opens.
18 Click OK.
19 Go to step 35.
Log into NE From NE List
20 Select action?
If open NE by opening a file containing a list of NEs, go to step 21.
If open NE from current file containing a list of NEs, go to step 29.
Open NE From Saved List of NEs
21 From the NETO Login window, click the Opens a file containing a list of favorite NEs.
icon. See Figure 128-7.
Figure 128-6. Network Elements List Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 269/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-217
DLP-128
Open window opens. See Figure 128-8.
Figure 128-7. NETO Overview Window
Figure 128-8. Open Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 270/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-218
DLP-128
22 Select the NE List file name <NE_List.neto>, then click Open.
Network Elements List window opens. See Figure 128-9.
23 Select the NE from the NEs table and click Set Current.
The NETO Login window opens. See Figure 128-10.
Figure 128-9. Network ElemenT List Window
Figure 128-10. NETO Overview Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 271/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-219
DLP-128
24 Click OK.
25 Click Show.
26 In the Login window, enter UserName “username” and Password “ password”.
27 Click Apply.
JUSM 9500MPR window launches. See Figure 128-11.
28 Go to step 35.
Open NE From Current List of NEs
29 From the NETO Login window, click the Opens the current list of favorite NEs. icon. See
Figure 128-12.
Figure 128-11. JUSM/CT 9500MPR-A Main Screen
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 272/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-220
DLP-128
Network Elements List window opens. See Figure 128-13.
30 Select the NE from the NEs Table and click Set Current.
The NETO Overview window opens. See Figure 128-14.
Figure 128-12. NETO Overview Window
Figure 128-13. Network ElemenT List Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 273/314
3EM23954ABIssue 01, February 2010
Administer NE Lists 4-221
DLP-128
31 Click OK.
32 Click Show.
33 In the Login window, enter UserName “username” and Password “ password”.
34 Click Apply.
JUSM 9500MPR window launches. See Figure 128-15.
Figure 128-14. NETO Overview Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 274/314
3EM23954ABIssue 01, February 2010
Administer NE Lists4-222
DLP-128
35 STOP. This procedure is complete.
Figure 128-15. JUSM/CT 9500MPR-A Main Screen
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 275/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 276/314
3EM23954ABIssue 01, February 2010
View Event Log4-224
DLP-129
2 Select action?
If export event log, go to step 3.If print event log, go to step 12.
Export Event Log
3 Select File/Export/Export Event.
Export Events window opens.
4 Select Output Format: HTML, CSV, PDF, or XML.
5Select What entries to you want to export: All Entries, or Selection.
6 Click OK.
Save window opens.
7 Navigate to the directory to save the Event Log.
Figure 129-2. Event Log Browser Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 277/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 278/314
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 279/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-227
DLP-130
DLP-130
IF Cable Loopback
PURPOSE
This procedure provides the instructions to perform MOD300 card IF Cable Loopback for the
9500 MPR.
GENERAL
IF Cable Loopback is active only on the cross-connections associated with TDM2TDM and TDM2Eth
profiles. Loopback of Ethernet traffic is not supported.
IF Cable Loopback can be activated from the local NE only.
For a block diagram of IF Cable Loopback, see Figure 130-1.
STEP PROCEDURE
1 In the main equipment window, double left click the MOD300 card to perform IF cable
loopback. See Figure 130-2.
Figure 130-1. IF Cable Loopback Block Diagram
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 280/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-228
DLP-130
The MSS Radio Main View for the selected radio direction opens.
2 Select action?
If activate IF cable loopback, go to step 3.
If deactivate IF cable loopback, go to step 15.
Activate IF Cable Loopback
3 Select Settings tab. See Figure 130-5.
Figure 130-2. Main Equipment Window: MOD300 Card Highlighted
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 281/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-229
DLP-130
4 Select TxMute Enable check-box.
5 Click Apply.
Tx Mute Settings dialog box displays.
6 Click Yes.
Command Summary dialog box displays.
7 Click OK.
Radio channel transmitter TxMute enabled. See Figure 130-4.
Figure 130-3. Radio Channel Settings Tab
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 282/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-230
DLP-130
8 Select Loopback tab. See Figure 130-5.
Figure 130-4. Transmitter TxMute Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 283/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-231
DLP-130
9 Select IF Cable.
10 Select Active radio button.
11 In the Timeout Period (max 4 days) fields enter the IF cable loopback duration.
Figure 130-5. MOD300 IF Cable Loopback Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 284/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-232
DLP-130
12 Click Apply.
The Loopback Setting dialog box displays.
13 Click OK.
MOD300 IF cable loopback active. See figure 130-7.
Figure 130-6. MOD300 IF Cable Loopback Provisioned
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 285/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-233
DLP-130
14 Go to step 23.
Deactivate IF Cable Loopback
15 Select Loopback tab. See Figure 130-8.
Figure 130-7. MOD300 IF Cable Loopback Active
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 286/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-234
DLP-130
16 Select IF Cable.
17 Select Not Active radio button. See figure 130-9.
Figure 130-8. MOD300 IF Cable Loopback Active
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 287/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-235
DLP-130
18 Click Apply.
MOD300 IF cable loopback deactivated (Not active). See figure 130-10.
Figure 130-9. MOD300 IF Cable Loopback Active, Not Active Selected
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 288/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-236
DLP-130
19 Select Settings tab. See Figure 130-11.
Figure 130-10. MOD300 IF Cable Loopback Deactivated (Not Active)
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 289/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback 4-237
DLP-130
20 Select TxMute Enable check-box (unchecked).
21 Click Apply.
Command Summary dialog box displays.
22 Click OK.
Radio channel transmitter TxMute disabled. See Figure 130-12.
NOTE: Recommend waiting 25 seconds before executing another command after disabling
TxMute.
Figure 130-11. Settings Tab, Transmitter TxMute Enabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 290/314
3EM23954ABIssue 01, February 2010
IF Cable Loopback4-238
DLP-130
23 STOP. This procedure is complete.
Figure 130-12. TxMute Disabled
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 291/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore) 4-239
DLP-131
DLP-131
MIB Database Management (Backup and Restore)
PURPOSE
This procedure provides the instructions to perform MIB Database Management (backup and
restore) on the 9500 MPR. MIB database restore should be performed for catastrophic recovery
ONLY.
GENERAL
CAUTION: Possibility of service interruption. ALL traffic will be interrupted during activate database
phase.
CAUTION: Possibility of service interruption. ALL traffic will be interrupted, upon completion of system
restart, the MSS-8 shelf must be power cycled to complete the database restore process.
The backup operation provides the ability to save a copy of NE configurations parameters stored on
the flash memory on the NE CSM Core card(s).
The restore operation provides the ability to restore a previously saved copy of NE configurations
parameters to the flash memory on the NE CSM Core card(s).
The following networking parameters are not saved during MIB Management Database Backup.
• Local IP address provisioning
• Local Ethernet Interface provisioning
• Static routing provisioning
• OSPF area provisioning
• NTP configuration
• PPP/RF configuration
• Loopbacks
• Manual protection switches
The above listed parameters are not affected during MIB Management Database Restore.
It is recommended that these parameters be saved by running a Current Configuration View report,
so these parameters may be reprovisioned in the event that the system needs to be restored from
scratch.
After completing the restore operation, the restored database must be activated to apply the
downloaded parameters to the NE. Upon activation of the restored database, the NE will
automatically restart.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 292/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore)4-240
DLP-131
Database backup should be performed with no forced protection switches active. A system restored
with a backup database that was saved while forced protection switches are active, may result in the
system being restored to an unknown state. If this occurs, communications with the system may be
difficult to reestablish and may result in the loss of traffic.
STEP PROCEDURE
1 Select the Protection Schemes tab.
2 Verify no forced protection switches are active.
3 Are forced protection switches active?
If yes, go to step 4.
If no, go to step 6.
4 CAUTION: Possibility of service interruption. Failure to release ALL protection switches
prior to performing a MIB Management database backup, may result in the system being
restored to an unknown state. If this occurs, communications with the system may be
difficult to reestablish and may result in the loss of traffic.
5 Determine if the active forced protection switch(es) can be released. Release ALL
forced protection switch(es) prior to proceeding with this procedure.
6 Select action?
If backup MIB Management database, go to step 7.
If restore MIB Management database, go to step 15.
If activate restored MIB Management database, go to step 23.
Backup MIB Management Database
7 Save current configuration data. Refer to DLP-116 for detailed instructions to view
and save current configuration data.
8 In the main Menu bar, select Supervision>MIB Management>Backup. See Figure 131-1.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 293/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore) 4-241
DLP-131
The Backup window opens. See Figure 131-2.
9 Navigate to the directory to save MIB Management Database.
10 Enter the file name of the MIB Management Database backup file in the File Name
field.
11 Click Save.
Backup confirmation window opens.
Figure 131-1. Backup MIB Management Database Path
Figure 131-2. Backup MIB Management Database Dialog Box
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 294/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore)4-242
DLP-131
12 Click Yes.
MIB Management window opens.
13 Click OK.
14 Go to step 34.
Restore MIB Management Database
15 In the main Menu bar, select Supervision>MIB Management>Restore. See
Figure 131-3.
The Restore window opens. See Figure 131-4.
Figure 131-3. Restore MIB Management Database Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 295/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore) 4-243
DLP-131
16 Navigate to the directory where the MIB Management Database backup file is saved.
17 Select the MIB Management Database backup file.
18 Click Open.
Restore confirmation window opens.
19 Click Yes.
MIB Management window opens.
20 Activate restored MIB Management Database?
If yes, go to step 24.
If no, go to step 21.
21 Click No.
22 Go to step 34.
Activate Restored MIB Management Database
23 In the main Menu bar, select Supervision>MIB Management>Activate. See
Figure 131-5.
Figure 131-4. Restore MIB Management Database Window
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 296/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore)4-244
DLP-131
The Activate confirmation window opens.
24 CAUTION: Possibility of service interruption. ALL traffic will be interrupted during activate
database.
25 Click Yes.
MIB Management window opens.
26 Click OK.
27 Close the WebEML window.
The NE will activate the restored MIB Management database. There may be a delay
of 60 to 90 seconds before the Activate process begins. The NE will automatically
restart. A loss communication with the NE will occur. Do not attempt any WebEML
activates until the NE has completed restarting. Once the craft realigns with the NE,
it is OK to log in to the system. Restarting the NE can take up to 10 minutes to
complete.
NOTE: Because MIB database restore does not affect local IP address provisioning, it will
be necessary to connect to the MSS-8 shelf using the same IP address used prior to
database restore. If no IP address provisioning was performed prior to MIB database restore
it will be necessary to connect to the MSS-8 shelf using the default IP address (10.0.1.2) and
the main TMN port.
28 CAUTION: Possibility of service interruption. ALL traffic will be interrupted, upon
completion of system restart, the MSS-8 shelf must be power cycled to complete thedatabase restore procedure.
29 Power cycle the MSS-8 shelf. Remove the fuses in the PDU supplying power to the
MSS-8 shelf.
30 Wait 15 seconds, install fuses in the PDU supplying power to the MSS-8 shelf.
Figure 131-5. Activate MIB Management Database Path
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 297/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore) 4-245
DLP-131
31 Once the system restarts and the craft is able to connect, log into the NE.
32 Verify system provisioning. Refer to the saved current configuration view, saved
during the MIB backup procedure.
33 Provision any required settings that are not restored as part of the backup/restore
process (e.g. IP address, NTP, etc.).
34 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 298/314
3EM23954ABIssue 01, February 2010
MIB Database Management (Backup and Restore)4-246
DLP-131
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 299/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC 4-247
DLP-132
DLP-132
Load System and Craft Terminal Software on PC
PURPOSE
This procedure is used to install 9500 MPR software.
GENERAL
Software Kit
Software Kit is delivered with each 9500 MPR. The software kit consists of the following three
CD-ROMs:
• 9500MPR-A CT R01.02.00 - Craft Terminal (CT) software - hereafter called
WebEML (JUSM/CT) - installed on the PC at initial Turn-Up
• 9500MPR-A SWP R01.02.00- radio application software - not required for initial
Turn-Up - hereafter called SWP
• v4.04.01 MIB - SNMP MIB software - not required for initial Turn-Up - hereafter
called MIB
The SWP and MIB software is downloaded on the NE flash card and the flash card is installed on
the CSM (Control and Switching Module) at the factory. It is not necessary to install SWP and MIB
software on the PC at initial Turn-Up. The SWP CD is supplied with the equipment for backup. The
MIB CD is supplied for use by third-party SNMP applications.
Flash Card
The flash card consists of:
• License Key
• MAC Address
• SW Load
PC Characteristics
The PC for Craft Terminal applications must meet following characteristics:
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 300/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC4-248
DLP-132
PC HW Configuration:
• CPU: Pentium III 850 MHz
• RAM: 512 Mbytes (minimum), 1 Gbyte (suggested)
• Min. disk space: 1.5 Gbyte's (available space needed, JRE excluded)
• Min. resolution: equal or higher than 1024x768 pixel
• CD-ROM Drive: 24x
• Primary Interface: Ethernet Card 10/100 Mbits/sec.
Operating Systems Supported:
• Microsoft Windows 32-bit versions: Microsoft Windows XP Professional service
pack 2 or Microsoft Windows Vista Business
Additional requirements:
• Microsoft Internet Explorer 6.0 6.02900.2180 SP1+ or higher or Microsoft
Internet Explorer 7.0.5730.11CO + or higher or Firefox 2.x Win32
• Administrator or Power User rights
• Java Runtime Environment (JRE) 6 Update 3 (Available on the CT CD-ROM)
There is no checklist for this procedure.
REQUIRED EQUIPMENT
Software Kit, Alcatel-Lucent PN: 3EM23052ADAA
Flash Card, Alcatel-Lucent PN: 3EM23055ADAA
RJ-45 Cat5E cable, Straight-through, Alcatel-Lucent PN:3EM15052xx
STEP PROCEDURE
1 Craft PC require a protective firewall?
If yes, go to step 2.
If no, go to step 21.
Configure Windows Firewall
The following procedure configures the PC to allow the CT to run on the PC with
Windows Firewall. The steps are specific for Windows XP SP2. Steps for Windows
Vista are similar.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 301/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC 4-249
DLP-132
2 Open the Windows Firewall Settings Dialog: Start-Settings-Control Panel-Windows
Firewall.
3 Select On (recommended) to enable firewall.
4 Ensure the Don’t allow exceptions box is unchecked.
NOTE: If you are unable to make changes to this setting (e.g. The setting is grayed
out/disabled), your computer or network security policy may not allow you to make changes.
Contact your network or domain system administrator.
5 Click OK.
Windows Firewall Settings Dialog window closes.
6 On desktop, click on CT icon to start CT application.
7 As application starts, several Windows Security Alert dialog boxes appear. Click
Unblock on each dialog box as it appears.
NOTE: After performing procedure steps and CT application will not run, verify that firewall
or anti-spying software is not set to block programs without confirmation. If programs are
being blocked without confirmation, change this setting to allow confirmation, and re-start
the Craft application to determine if additional exceptions are necessary.
NOTE: Some firewall or intrusion prevention software will prevent reception of SNMP trap
messages from 10.x.x.x IP addresses, which are the default addresses for the 9500 MPR. If
operations such as provisioning equipment, creating/deleting cross-connects, etc. are
failing with either a system error or the Craft application becoming unresponsive, you may
need to allow an exception for 10.x.x.x addresses or change the IP address of the 9500 MPRunits involved.
NOTE: If an external firewall is being used, exceptions will need to be added for TCP port 21
(FTP) and udp port 5010 (SNMP).
Verify JAVA JRE Software Version
NOTE: The user's PC must have at least the Java 6 update 3 software installed.
8 Method to verify JAVA JRE software version?
If Control Panel, go to step 9.If DOS Prompt, go to step 15.
9 Click Start.
10 Click Control Panel and double click the Java icon.
11 Select About.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 302/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC4-250
DLP-132
12 Verify Java JRE software installed on the PC is at least Version 6 Update 3.
13 Click Close.
14 Go to step 21.
15 Click Start.
16 Select Run from the pop-up window.
17 Type cmd.
18 At the DOS prompt, type java -version.
19 Verify Java JRE software installed on the PC is at least Version 6 Update 3.
20 Click the X to close the DOS prompt window.
Install/Upgrade JAVA JRE Software
NOTE: The user's PC must have at least the Java 6 update 3 software installed.
21 Install/upgrade JAVA JRE on to the PC?
If yes, go to step 22.
If no, go to step 32.
22 Insert the WebEML (JUSM/CT) CD into the CD-ROM drive.
The CD will auto-run (if auto-run is enabled on the user's PC) and open up the
installation wizard.
NOTE: If auto-run does not start, user must run (double-click with left mouse button) the
Setup.exe file, available in the WebEML (JUSM/CT) CD-ROM root directory, in order to
launch the WebEML (JUSM/CT) installation wizard.
23 Installation wizard welcome screen will display after the auto-run or running the CD
manually. Click Next to continue.
24 Click Next to choose the components to install.
25 Select the Java Runtime Environment option. Click Install.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 303/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC 4-251
DLP-132
26 Click Yes to install the JRE 6 update 3 or No to cancel the Java installation.
NOTE: If the user's PC has JRE 6 update 3 or a newer Java version installed, clicking Yes
will install the JRE 6 update 3 over the existing JRE 6 update 3 but the newer version will not
be deleted. The PC will still run the most current Java version regardless if the JRE 6 update
3 is installed.
27 If the user's PC needs this Java version, click Yes to the WARNING screen above and
the JRE installation will begin.
28 Click Accept.
29 Click Finish.
30 If the user's PC has this Java version installed, this caution will appear. Click No.
31 Click Finish to complete the JRE installation.
Install WebEML (JUSM/CT) Software
32 Install WebEML (JUSM/CT) on to the PC?
If yes, go to step 33.
If no, go to step 38.
33 Insert the WebEML (JUSM/CT) CD into the CD-ROM drive.
The CD will auto-run (if auto-run is enabled on the user's PC) and open up the
installation wizard.
NOTE: If auto-run does not start, user must run (double-click with left mouse button) the
Setup.exe file, available in the WebEML (JUSM/CT) CD-ROM root directory, in order to
launch the WebEML (JUSM/CT) installation wizard.
34 Installation wizard welcome screen will display after the auto-run or running the CD
manually. Click Next to continue.
35 Click Next to choose the components to install.
36 Select the WebEML (JUSM/CT) option. Click Install.
WebEML (JUSM/CT) is installed on the PC.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 304/314
3EM23954ABIssue 01, February 2010
Load System and Craft Terminal Software on PC4-252
DLP-132
37 Click Finish to complete the WebEML (JUSM/CT) installation and exit the installation
wizard.
The MPR-A (WebEML) icon will be created automatically on the desktop after the
installation process.
38 STOP. This procedure is complete.
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 305/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide 5-1
WebEML Craft Terminal Reference Guide
1. INTRODUCTION
1.1 The WebEML craft terminal reference guide provides user guide to the
WebEML craft terminal. Defines the various page layouts, navigation, and
resources available to quickly monitor the condition of a 9500 MPR radio.
Main Screen Overview
1.2 The main screen view is the entry point of the application and provides
the basic diagnostic and configuration functions. This first screen shows a highlevel overview of the areas on the main screen. See Figure 1-1.
Figure 1-1. WebEML Main Screen
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 306/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide5-2
1.3 The main screen is comprised of the following areas.
• Main Menu Bar Area
•
Main Tool Bar Area
• Resource Tree Area
• Resource List Area
• Resource Detail Area
• Severity Alarm Synthesis Area
• Domain Alarm Synthesis Area
• Status Control Area
Main Menu Bar Area
1.4 The main menu bar area allows the management of the 9500 MPR NE
resources function to access all the menu options, performing all the
configuration and supervision functions of the Network Element. See
Figure 1-2.
1.5 The main menu bar has the following drop-down menus:
• Views
• Configuration
• Diagnosis
•
Supervision
• SW Download
• Equipment
Figure 1-2. Main Menu Bar
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 307/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide 5-3
Main Tool Bar Area
1.6 This main tool Bar area contains a selection of quick-access icons to access
common features. See Figure 1-3.
1.7 The main Tool Bar Area has the following quick-access icons:
• Backward
• Forward
• Zoom
• Block Diagram View
• Configuration View
• Cross-Connections
Resource Tree Area
1.8 Resource Tree Area displays all the available resources of the Radio
NE in a tree structure. See Figure 1-4.
Figure 1-3. Main Tool Bar Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 308/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide5-4
1.9 Each tree node consists of two symbols. The first symbol indicates the
state of the structure, e.g., if the symbol has a "+" the tree can be expanded to
a lower level. The tree structure can be collapsed if the symbol is a "-". Finally,
if there is no symbol, the node represents a leaf. The second symbol is the
graphical representation of the resource.
1.10 The user must select the resource by clicking with the mouse to carryout an action that depends on the type of click and the Resource Detail Area
related to the selected element that is displayed. Each resource listed may be
selected by using the mouse with a single mouse click or a double mouse click.
Figure 1-4. Resource Tree Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 309/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide 5-5
1.11 Single Left Click: By a single left mouse click the resource is
highlighted. This selection causes the activation of the resource list area, e.g.,
every time the user selects a resource in the resource tree area the
corresponding Tabular or Graphical representation is displayed in the
Resource List Area.
1.12 Double Left Click: Using this type of selection on the items of the resource
tree, the user can expand the tree structure and activate the Resource List Area
displaying the same information described above. When the tree node is expanded,
a double click will collapse the tree node showing the same information in the
Resource List Area.
Resource List Area
1.13 The resource list area provides a graphical view of the NE. Additional
resource function to access additional menu for performing configuration andsupervision functions of the Network Element. See Figure 1-5.
Resource Detail Area
1.14 The Resource Detail area allows the management of the 9500 MPR NEresources function to access alarm details, configuration settings, and remote
inventory details for the Network Element. See Figure 1-6.
Figure 1-5. Resource List Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 310/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide5-6
Severity Alarm Synthesis Area
1.15 The Severity Alarm Synthesis Area provides an alarm functionality
that informs the operator on the severity of the different alarms in the NE as
well as on the number of current alarms. See Figure 1-7.
1.16 There are six different alarm severity levels. These different levels are
associated with colors as follows:
• Green: Normal condition
• Red: Critical alarm (CRI)
• Orange: Major alarm (MAJ)
•
Yellow: Minor alarm (MIN)
• Cyan: Warning alarm (WNG)
• White: Indeterminate (IND) Not operative.
Figure 1-6. Resource Detail Area
Figure 1-7. Severity Alarm Synthesis Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 311/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide 5-7
1.17 Each alarm severity is represented by an alarm icon situated in the
top left hand corner of the view. These alarm icons are constantly represented
on the different Equipment views (NE view, Module view or Port view) so that
the operator is always aware of the alarms occurring in the system.
1.18 The shape of the alarm icons in the alarm panel gives an indication of
alarm occurrence.
1.19 An alarm icon with a rectangle inside indicates that no alarms of the
type defined by the icon are occurring. See Figure 1-7.
1.20 An alarm icon with a circle inside it (and a number at the bottom of the
icon) indicates that alarms of the number and the type defined by the icon are
occurring. See Figure 1-8.
1.21 An alarm icon grayed out indicates that a spontaneous incoming
alarm notification has been inhibited.
Domain Alarm Synthesis Area
1.22 The Domain Alarm Synthesis Area provides an alarm functionality
that informs the operator on the domain of the different alarms in the NE as
well as on the number of current alarms. There are different alarm domain
types according to the different domains in which the NE can be subdivided
(example: External (EXT), Equipment (EQP), Transmission (TRS)). See
Figure 1-9.
Figure 1-8. Severity Alarm Synthesis Area: Alarm Condition
Figure 1-9. Domain Alarm Synthesis Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 312/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide5-8
1.23 The color corresponds to the highest severity among the set of active
alarms for the relevant domain. There are six different alarm severity levels.
These different levels are associated with colors as follows:
•
Green: Normal condition
• Red: Critical alarm (CRI)
• Orange: Major alarm (MAJ)
• Yellow: Minor alarm (MIN)
• Cyan: Warning alarm (WNG)
• White: Indeterminate (IND) Not operative.
1.24 Each domain alarm is represented by an alarm icon situated in the top
right hand corner of the view. These alarm icons are constantly represented on
the different domain types so that the operator is always aware of the alarms
occurring in the system.
1.25 The shape of the alarm icons in the alarm panel gives an indication of
alarm occurrence. An alarm icon with a rectangle inside indicates that no
alarms of the type defined by the icon are occurring. See Figure 1-10.
1.26 An alarm icon with a circle inside it (and a number at the bottom of the
icon) indicates that alarms of the number and the type defined by the icon are
occurring. See Figure 1-10.
1.27 An alarm icon grayed out indicates that a spontaneous incoming
alarm notification has been inhibited.
Status Control Area
1.28 The Status Control Area provides different management states
concerning the NE and are represented via icons located on the right side of the
Resource List Area. See Figure 1-11.
Figure 1-10. Domain Alarm Synthesis Area: Alarm Condition
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 313/314
3EM23954ABIssue 01, February 2010
WebEML Craft Terminal Reference Guide 5-9
1.29 Refer to Table 1-A for the seven management status icon and color
definitions.
Figure 1-11. Status Control Area
8/9/2019 9500 MPR O _26 M
http://slidepdf.com/reader/full/9500-mpr-o-26-m 314/314