1 NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 www.entes.com.tr Product Code MPR-52S (new) MPR-50 (new) MPR-63-40 MPR-63-20 MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics MEMORY Memory Digital Input Digital Input mA Analogue Output Analogue Output PC Interface Software (MPR-SW) : MPR-SW is a graphic based software, which enables remote monitoring via internet or intranet. Please refer to page 20 for MPR-SW Software. General Alarm Contact Alarm Contact MPR-50 MPR-52S : . : with with with Network Analyser Network Analyser S-485 Network Analyser S-485 Network Analyser S-485 THD measurement, R (MODBUS) and Alarm Contact. : THD measurement, R (MODBUS), Alarm Contact and 1MB Memory. : THD, up to 31th Harmonics measurement, R (MODBUS), Alarm Contact and 1MB Memory. MPR-60S MPR-63 IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1 Max. Demand Max. Demand MD % THD I, THD V 2-31th Harmonics I neutral Alarm Contact Digital Input RS-485 Comm. 0(2)-10V 0(4)-20mA Memory Real Time Clock LCD Display Pcs / Carton 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Energy Pulse Output MPR-63 Modbus / Ethernet Gateway Table View Harmonics View Front Panel View

Upload: others

Post on 27-May-2020

95 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

1

NETWORK ANALYSER

MPR-50 / MPR-52S / MPR-60S / MPR-63

www.entes.com.tr

Product Code

MPR-52S (new)

MPR-50 (new)

MPR-63-40

MPR-63-20

MPR-63-10

MPR-63

MPR-60S-41

MPR-60S-40

MPR-60S-20

MPR-60S-10

MPR-60S

MPR-52S-10 (new)

MPR-63-41

Modbus

Harmonics

MEMORY

Memory

DigitalInputDigitalInput

mA

AnalogueOutput

AnalogueOutput

PC Interface Software (MPR-SW) :MPR-SW is a graphicbased software, which enablesremote monitoring via internetor intranet.

Please refer to page 20 forMPR-SW Software.

General

Alarm ContactAlarm Contact

MPR-50

MPR-52S

: .

: with

with

with

Network Analyser

Network Analyser

S-485

Network Analyser

S-485

Network Analyser

S-485

THD measurement,

R (MODBUS) and Alarm Contact.

: THD measurement,

R (MODBUS), Alarm Contact and 1MB Memory.

: THD, up to 31th Harmonics

measurement, R (MODBUS), Alarm Contact and

1MB Memory.

MPR-60S

MPR-63

IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1

Max. DemandMax. Demand

MD

%THDI,THDV

2-31thHarm

onics

Ineutral

Alarm

Contact

DigitalInput

RS-485Comm.

0(2)-10V

0(4)-20mA

Memory

Real TimeClock

LCDDisplay

Pcs/Carton

8

8

8

8

8

8

8

8

8

8

8

8

8

8

EnergyPulseOutput

MPR-63

Modbus / EthernetGateway

Table View

Harmonics View

Front Panel View

Administrator
Text Box
Page 2: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

Phase - NeutralVoltages (VLN)

Phase - PhaseVoltages (VLL)

Average Phase -Neutral Voltage

Average Phase -Phase Voltage

Phase Currents (I)

Neutral Current

Total Current ( I)�

Power Factor (P.F)

Cos�

Frequency (Hz)

Active Power (P)

Reactive Power (Q)

Apparent Power (S)

Total Active Power ( P)�

Total Reactive Power ( Q)�

Active Energy -Import (kWh)

Active Energy -Export (kWh)

Reactive Energy -Capacitive (kVArh)

Reactive Energy -Inductive (kVArh)

Total Apparent Power ( S)�

Max. Demand

Max / Min. Values

Measured Parameters ( MPR-50 )

Measured Parameters ( MPR-52S / MPR-60S )

Total Harmonic Distortionfor Voltage (THD V %)

Total Harmonic Distortionfor Current (THD I %)

Measured Parameters ( MPR-63 )

Individual Harmonicsfor Voltage - up to 31th

Individual Harmonicsfor Current - up to 31th

247 DEVICES CAN BE CONNECTED SERIALLY BY USING REPEATERS.

MPR-63#247

...MPR-63

#1MPR-63#31

REPEATERRPT-1

MAX. 1200 mt. MAX. 1200 mt.RS485/USB or ETHERNET

CONVERTER

RPT-01

MPR-63#246

NETWORK ANALYSER

MPR-50 / MPR-52S / MPR-60S / MPR-63

2

www.entes.com.tr

Administrator
Text Box
Page 3: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

MPR-63MPR60SMPR52SMPR50

SPECIFICATIONS

Output 3 :

Output 4 :

ActiveEnergyPulseOutput(1kWh...50MWh/pulse)

ReactiveEnergyPulseOutput(1kVArh...50MVArh /pulse)

Energy Pulse Output

Min. 1 sec.(100...2500 msec. pulse width)Switch Period

Max. 50 mAOperation Current

0/4-20mA 0/2-10V )(MPR6X- , MPR6x- ) / (MPR6x-40 41 21Analog Output (optional)

3,6” LCD with Backlight, 12 mm HeightDisplay

Selectable 28 parameters with Time Stamp (15.000 records)Data Logging

Double Isolation ( )Equipment Protection

-5oC, +55

oCAmbient Operating Temperature

Terminal / Flush-mounting with rear terminalsConnection / Installation

96x96 mm (PR19)Dimensions

0,9 kgWeight / each

8 pcsQuantity in 1 package

1 MB Internal MemoryMemory

Digital Output

85-265V AC / DC ; 50/60 HzOperating Voltage

3-phase / 4-wire (Star) 3-phase / 3-wire (Delta) 3-phase / 3-wire (Aron); ;Network Type

Accuracy

0,5 % ± 2 digitVoltage

0,5 % ± 2 digitCurrent

0,1 % ± 2 digitFrequency

1...2000 (programmable)Current Transformer Ratio

1,0…4000,0 (programmable)Voltage Transformer Ratio

Measurement input

1,0 - 300,0 V AC (P-N), 2,0 - 500,0 V AC (P-P)Voltage

5 mA - 5,5 ACurrent

Measurement Ranges

1,0 - 400,0 kVVoltage

5 mA - 10.000 ACurrent

45,0 - 65,0 HzFrequency

0 - 4.000 M (W, VAr, VA)Power

0 - 99.999.999 kWh, kVArhEnergy

< 6 VAPower Consumption

15 min. (Programmable via MPR-SW)Demand Time

MODBUS RTU (RS-485)Communication Interface

1.200 - 38.400 bps / 1 - 247 / None, Odd, EvenBaud Rate / Adress / Parity

2 NO relays , 5A, 1250 VA (resistive)1 / 2 :Output OutputAlarm Contact Output

< 1 VA (Current burden), < 0,5 VA (Voltage burden)Burden

1 % ± 2 digitActive Power

2 % ± 2 digitReactive Power

THD V%, THD I%2 - 31th separatelyvoltage currentTHD V%, THD I%

&Harmonic Measurement

Output Output3 / 4 : 2 Digital InputsDigital Input

Real Time / LatchFunctions

50 msec. (Min.)Input Pulse Width

5...24VDC, 30VDC (Max.)Operation Voltage

3

www.entes.com.tr

forMPR-52S-

MPR6x-

10

&10

Degree of Protection IP40 (front panel), IP54 (Optional)

Mechanical Parameters

Electrical Parameters

MODEL

MPR63-M

PR60

MPR63-

/

S

41

21

MPR60-

/S

21

41

Operation Voltage 5...24V DC, max. 30V DC

NETWORK ANALYSER

MPR-50 / MPR-52S / MPR-60S / MPR-63

(new) (new)

Administrator
Text Box
Page 4: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

4

www.entes.com.tr

DimensionsConnection Diagram

(PR19- 96x96mm)

3 Phase with neutral connection

RS-485

L1 L2 L3

1 2 3 4 5 6

17 18 19 20 21 22 23 24 2625

11 12 13

GND

14

A

15

B

16

TR

7L1

8L2

9L3

10N

ExternalSupply

Voltage Measurement Inputs

Current Measurement Inputs+_

Max:30VDC

k l

K L

k l

K L

1. Relay 1 3. PulseA2. Relay 2 4. PulseR

Pulse R

3 Phase without neutral Aron connection.1A

L1N

TYPE PR 19

RS-485

L1 L2 L3

1 2 3 4 5 6

17 18 19 20 21 22 23 24 2625

11 12 13

GND

14

A

15

B

16

TR

7L1

8L2

9L3

10N

L2

L3

N

ExternalSupply

Voltage Measurement Inputs

Current Measurement Inputs

+_

Max:30VDC

k l

K L

k l

K L

k l

K L

1. Relay 1 2. Relay 2 3. PulseA 4. PulseR

Pulse A Pulse R 1A

L1

N

L1

RS-485

L1 L2 L3

1 2 3 4 5 6

17 18 19 20 21 22 23 24 2625

11 12 13

GND

14

A

15

B

16

TR

7L1

8L2

9L3

10N

ExternalSupply

Voltage Measurement Inputs

Current Measurement Inputs

+_

Max:30VDC

k l

K L

k l

K L

k l

K L

1. Relay 1 2. Relay 2 3. PulseA 4. PulseR

Pulse A Pulse R

3 Phase without neutral connection

1A

L1

N

L2

L3

L1

L2

L3

L1

Pulse A

RS-485

11 12 13

GND

14

A

15

B

16

TR

AnalogOut

RS-485

L1 L2 L3

1 2 3 4 5 6

17 18 19 20 21 22 23 24 2625

11 12 13

GND

14

A

15

B

16

TR

7L1

8L2

9L3

10N

L1L2

L3

N

ExternalSupply

Voltage Measurement Inputs

Current Measurement Inputs

+_

Max:30VDC

k l

K L

k l

K L

k l

K L

1. Relay 1 2. Relay 2 3. PulseA 4. PulseR

Pulse A Pulse R

AnalogOut

3 Phase with neutral connection

1A

L1N

MPR-63 MPR-63

MPR-63MPR-63-10MPR-60S-10MPR-52-10

MPR-63-41MPR-60S-41

RS-485

L1 L2 L3

1 2 3 4 5 6

17 18 19 20 2625

11 12 13

GND

14

A

15

B

16

TR

7L1

8L2

9L3

10N

L1L2

L3

N

ExternalSupply

Voltage Measurement Inputs

Current Measurement Inputs

k l

K L

k l

K L

k l

K L

1. Relay 1 2. Relay 2

21 22 23 24

3. Input 1

Max:30VDC

Input 1 Input 2

+_

4. Input 2

3 Phase with neutral connection

1A

L1

N

Connection diagrams are given for reference. Please always check latest user manual given with product or download from www.entes.com.tr.the

96

79.3

70

90

96

NETWORK ANALYSER

MPR-50 / MPR-52S / MPR-60S / MPR-63

Administrator
Text Box
Page 5: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

DIGITAL NETWORK ANALYSER

MPR-53 / EPM-07 Series

Product Code

MPR-53S -DIN

MPR-53S -96

EPM-07S -DIN

EPM-07S -96

RS-485Comm.

EPM-07 -DIN

EPM-07 -96

MPR-53 -DIN

MPR-53 -96

EPM-07S -DIN-CT-25 (new)

MPR-53S -DIN-CT25 (new)

CT-25(210A)

.../5A

Pcs/Carton

12

12

12

12

12

12

12

12

12

12

Modbus Harmonics Alarm ContactAlarm Contact

Alarm

Contact

(Soon)

EnergyPulseOutput

%THDV

%THDI

DigitalInput

DualEnergyMeter

6DifferentEnergy

CalculationMethods

NeutralCurrent

General

MPR-53 eries measur parameters of an

electric More than 50 parameters are displayed.

Network Analyser

Network Analyser S-485

Network Analyser with

Network Analyser with

S-485

/ EPM-07 s es many

network.

: .

: with R (MODBUS).

: THD measurement.

: THD measurement and

R (MODBUS).

IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1

EPM-07

EPM-07S

MPR-53

MPR-53S

PC Interface Software (MPR-SW) :MPR-SW is a graphicbased software, which enablesremote monitoring via intranet orinternet.

Please refer to page 20 forMPR-SW Software.

MPR-53S-DIN-CT25

CT-25 is a Current Transformer, which is used together withMPR-53S-DIN-CT25 model.

It is a unique solution, which replaces conventional type CTsup to 210A.

5

www.entes.com.tr

Optional - Min. Order Quantity is 200pcs/device.

MPR-53S-96

Max. DemandMax. Demand

MD

Modbus / EthernetGateway

new

Administrator
Text Box
Page 6: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

Phase - NeutralVoltages (VLN)

Phase - PhaseVoltages (VLL)

Average Phase -Neutral Voltage

Average Phase -Phase Voltage

Phase Currents (I)

Neutral Current

Total Current ( I)�

Power Factor (P.F)

Cos�

Frequency (Hz)

Active Power (P)

Reactive Power (Q)

Apparent Power (S)

Total Active Power ( P)�

Total Reactive Power ( Q)�

Active Energy -Import (kWh)

Active Energy -Export (kWh)

Reactive Energy -Capacitive (kVArh)

Reactive Energy -Inductive (kVArh)

Total Apparent Power ( S)�

Max. Demand

Max / Min. Values

Measured Parameters ( EPM-07 / 07S )

Measured Parameters ( MPR-53 / MPR-53S )

Total Harmonic Distortionfor Voltage (THD V %)

Total Harmonic Distortionfor Current (THD I %)

247 DEVICES CAN BE CONNECTED SERIALLY BY USING REPEATERS

MPR53S-96#247

...MPR53S-DIN

#1MPR-63#31

REPEATERRPT-1

MAX. 1200 mt. MAX. 1200 mt.

RPT-01

EPM-07S#246

6

www.entes.com.tr

DIGITAL NETWORK ANALYSER

MPR-53 / EPM-07 Series

RS485/USB or ETHERNETCONVERTER

Administrator
Text Box
Page 7: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

7

www.entes.com.tr

SPECIFICATIONS

RS-485 Communication

Energy Pulse Output

Display Demand Value

Display Max/Min Values

Password Protection

Operating Voltage

Network Type

Accuracy

Current Transformer Ratio

Voltage Transformer Ratio

Measurement input

Voltage

Current

Measurement Ranges

Voltage

Current

Frequency

Power Factor

Power

Energy

Power Consumption

Demand Time

Communication Interface

Baud Rate

Address

Parity

Energy Pulse Output

Switch Period

Operation Current

Operation Voltage

Display

Equipment Protection

Ambient Operating Temperature

Degree of Protection

Connection / Installation

Dimensions

Weight / each

Quantity in 1 package

Burden

THD

Digital Input

Input Pulse Width

Operation Voltage

EPM-07 EPM-07S

3-phase / 3-wire (Aron)

3-phase / 3-wire (Delta)

3-phase / 4-wire (Star)

1% ±1 digit

1…2000 (programmable)

12 pcs (PR19), 12 pcs (DIN6)

Terminal / Flush-mounting with rear terminals

< 4 VA

5…24 V DC, max. 30 V DC

Red LED ; 10 mm Height

96x96 mm (PR19**), DIN6 (PK26**)

0,6 kg (PR19) ; 0,6 kg (DIN6)

1 - 247

IP40 (front panel)

-5 C, +55 Co o

MODBUS RTU (RS-485) [for EPM-07S & MPR-53S]

Max. 50 mA

No, odd, even

Min. 1,6 sec. (400 msec. pulse width)

NPN Transistor

1200 - 38400 bps

0 - 200 M (W, VAr, VA)

0, (programmable)1…4000,0

1 - 60 min. (programmable)

4 quadrant

0 - 99 999 999 999,9 kWh, kVArh

230 V AC ±10%; 45 / 65 Hz*

10 - 500 V (direct), 10 - 400 kV (with voltage transformer)

20 - 90 Hz

10 - 300 V AC (L-N), 10 - 500 V AC (L-L)

50 mA - 5,5 A

50 mA - 5,5 A (direct), 50 mA - 10.000 A (with current transformer)

Double Insulation ( ), Measurement Category III

< 1 VA (Current burden), < 0,5 VA (Voltage burden)

0-99.9 %

50 msec. (Min.)

5...24 V DC, 30 V DC (Max.)

2 Digital Inputs

MPR-53 MPR-53S

THD %V, THD %I

Functions

MODEL

Electrical Parameters

Mechanical Parameters

-

DIGITAL NETWORK ANALYSER

MPR-53 / EPM-07 Series

Administrator
Text Box
Page 8: NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 · MPR-63-10 MPR-63 MPR-60S-41 MPR-60S-40 MPR-60S-20 MPR-60S-10 MPR-60S MPR-52S-10 (new) MPR-63-41 Modbus Harmonics Y Memory Digital

TYPE PR 19

DimensionsConnection Diagram

(PR 19- 96x96mm)

(PK 26 - DIN6)

Connection diagrams are given for reference. Please always check latest user manual given with product or download from www.entes.com.tr.the

MPR-53SMPR-53S

MPR-53S

MPR-53S MPR-53S

MPR-53S

96

96

90

79.3

70

60.6

106.0

10.8 30.1 7.6 9.5

26.5 21.5

53.058.0

10.0

8.5

14.0

45.0

90.0

TYPE DIN / PK 26

DIGITAL NETWORK ANALYSER

MPR-53 / EPM-07 Series

8

www.entes.com.tr

Administrator
Text Box