    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic

    Educational-goals:

    You are informed over

    Diagnostic via LEDs Diagnostic with AOP30 Diagnostic with STARTER Messages for Faults and Warnings Diagnostic functions

    Fault finding and testing

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    2/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    LEDs while the control unit is booting

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    3/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    LEDs after the CU has booted

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    4/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    LEDs other Components

    Motor Module

    Active Line Module

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    5/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Properties of the fault buffer:

    A new fault incident encompasses one or more faults and is entered in fault incident 1.

    The entries are arranged in the buffer according to their time of occurrence.

    If a new fault incident occurs, the fault buffer is reorganized. This history is recorded in fault

    incidents 2 to 8.

    If the cause of at least one fault in fault incident 1 is remedied and acknowledged, the fault buffer

    is reorganized. The faults which have not been remedied remain in fault incident 1.

    When 8 faults have been entered in fault incident 1 and a new fault occurs, the fault in theparameters in index 7 is overwritten by the new fault.

    r0944 is incremented each time the fault buffer changes.

    A fault value (r0949) can be output for a fault. The fault value is used to diagnose the fault

    accurately; please refer to the fault description for details of the meaning.

    Clearing the fault buffer: POWER ON clears the entire buffer.

    The fault buffer is reset as follows: p0952 = 0.

    Properties of the fault buffer:

    A new fault incident encompasses one or more faults and is entered in fault incident 1.

    The entries are arranged in the buffer according to their time of occurrence.

    If a new fault incident occurs, the fault buffer is reorganized. This history is recorded in fault

    incidents 2 to 8.

    If the cause of at least one fault in fault incident 1 is remedied and acknowledged, the fault buffer

    is reorganized. The faults which have not been remedied remain in fault incident 1.

    When 8 faults have been entered in fault incident 1 and a new fault occurs, the fault in theparameters in index 7 is overwritten by the new fault.

    r0944 is incremented each time the fault buffer changes.

    A fault value (r0949) can be output for a fault. The fault value is used to diagnose the fault

    accurately; please refer to the fault description for details of the meaning.

    Clearing the fault buffer: POWER ON clears the entire buffer.

    The fault buffer is reset as follows: p0952 = 0.

    Fault Buffer

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    6/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic with fault buffer

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    7/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic with warning buffer

    Properties of the warning buffer:

    The entries are arranged in the buffer according to their

    time of occurrence.

    When 8 warnings have been entered in the warning buffer

    and a new warning occurs, the warning in the parameters

    in index 7 is overwritten by the new warning.

    r2121 is incremented each time the warning bufferchanges.

    A warning value (r2124) can be output for a warning. Thewarning value is used to diagnose the warning accurately;

    please refer to the warning description for details of the

    meaning.

    Clearing the warning buffer: POWER ON clears the entire

    buffer.

    The warning buffer is reset as follows: p2111 = 0

    Properties of the warning buffer:

    The entries are arranged in the buffer according to their

    time of occurrence.

    When 8 warnings have been entered in the warning buffer

    and a new warning occurs, the warning in the parameters

    in index 7 is overwritten by the new warning.

    r2121 is incremented each time the warning bufferchanges.

    A warning value (r2124) can be output for a warning. Thewarning value is used to diagnose the warning accurately;

    please refer to the warning description for details of the

    meaning.

    Clearing the warning buffer: POWER ON clears the entire

    buffer.

    The warning buffer is reset as follows: p2111 = 0

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    8/17

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    9/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic via parameter

    r0002 Drive status

    r0046 missing enable signalsr0050 active CDSr0721 actual terminal value CU320 Dig. I/Or0747 status of dig. Outputs CU320r4022 status of TM31 DIr4047 status of TM31 DO

    r0002 Drive status

    r0046 missing enable signalsr0050 active CDSr0721 actual terminal value CU320 Dig. I/Or0747 status of dig. Outputs CU320r4022 status of TM31 DIr4047 status of TM31 DO

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    10/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostics with STARTER: Current actual value, phase

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    11/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic by STARTER

    Control panelControl panel

    StatusStatus

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    12/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Drive navigator

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    13/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostics drives

    C) Entire diagnostic

    A) Control/status word, Statusparameter, missing enables

    B) Interconnections

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    14/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Diagnostic by STARTER: comparisation of parameters

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    15/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Function generator

    Operating modes of the function generator:

    1. Connector output2. Current setpoint downstream of filter (current setpoint filter)

    3. Disturbing torque (downstream of current setpoint filter)

    4. Speed setpoint downstream of filter (speed setpoint filter)

    5. Current setpoint upstream of filter (current setpoint filter)

    6. Speed setpoint upstream of filter (speed setpoint filter)

    parameterizable signal shapes

    -- Square--wave

    -- Staircase

    -- Triangular

    -- PRBS (pseudo random binary

    signal, white noise)

    -- Sinusoidal

    The function generator can be used to

    generate different signal shapes. Depending on the mode setting, this setpointcan then be fed into the control system, forexample as a current setpoint, disturbingtorque or speed setpoint.

    The impact of superimposed control loops isautomatically suppressed.

    6

    3 42 5

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    16/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Trace Functions

    The trace function can beused to record measuredvalues over a definedperiod depending ontrigger conditions.

    Trigger signals

    Trigger start Trace recorder

    Diagram types:

    Time diagram FFT-Diagram Bode diagram

    Recording duration

    Trigger definition

    Trace 1 with 4 signalsTrace 2 with 4 signals 2 Triggers (differently or resembles)

  • 8/11/2019 3diagnostic-140309121447-phpapp02

    17/17

    SINAMICS S120Siemens Ltda. 2009. All rights reserved. Date: 21.07.2009

    Measuring functions Current controller setpoint change (behind the current setpoint filter)

    Current controller reference frequency response (behind the current setpoint filter)

    Speed controller setpoint change (behind the speed setpoint filter)

    Speed controller disturbance step change (fault behind the current setpoint filter)

    Speed controller reference frequency response (behind the speed setpoint filter)

    Speed controller reference frequency response (upstream of the speed setpoint filter)

    Speed controller interference frequency response (fault behind the current setpoint

    filter)

    Speed-controlled system (excitation downstream of current setpoint filter)

    Optimization of a drive with

    prepared suppression of theoverlaid rule-circles.

    Very clearly programmable. Already prepares

    Function-generator Trace channel

    Speed controller setpoint change

    Speed controller reference frequency response