2 boening en sas

Upload: oezguer-oez

Post on 09-Apr-2018

237 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/8/2019 2 Boening en SAS

    1/83

    Alarm & Monitoring Systems

    Data station Data station Data converter

    Display Display

    CAN-Bus

    Modular System

  • 8/8/2019 2 Boening en SAS

    2/83

    Alarm & Monitoring Systems

    Data stations

    AHD-SAS 15

    AHD-PS 47 / AHD-PS 30 / AHD-PS 15

    AHD-R 101

    AHD 882

  • 8/8/2019 2 Boening en SAS

    3/83

    Alarm & Monitoring Systems

    Data converter

    AHD-UIC

    AHD-UCC

  • 8/8/2019 2 Boening en SAS

    4/83

    Alarm & Monitoring Systems

    Displays with integrated PC, Monitors

    AHD 1019 M

    AHD 1015 TC

    AHD 919

    AHD 915 TC

  • 8/8/2019 2 Boening en SAS

    5/83

    Alarm & Monitoring Systems

    Display and Control Units

    AHD 651

    AHD 880 TC

    Kompakt EDA 47

    Accessories

    AHD 650 R

  • 8/8/2019 2 Boening en SAS

    6/83

    Alarm & Monitoring Systems

    Data stations

    AHD-SAS 15

    AHD-PS 47 / AHD-PS 30 / AHD-PS 15

    AHD-R 101

    AHD 882

  • 8/8/2019 2 Boening en SAS

    7/83

    AHD-SAS 15 Data station

    15 inputs

    for analog and binary sensors

    CAN

    2 serial

    outputs

    2 serial

    inputs

  • 8/8/2019 2 Boening en SAS

    8/83

    AHD-SAS 15 Data station

    15 input channels individuallyfitted with pluggable analog

    input modules for acquisition

    of analog and binary signals

    15 inputs

    for analog and binary sensors

    Input/Sensor signal Type Analog

    module/

    Article number

    activ e pass iv e

    4-20 mA, 2-pole sensor

    - Sensor without external power supply

    B / 11109 x

    4-20 mA, 4-pole sensor

    - Sensor with external power supply

    C / 11110 x

    Contact via voltage measurement

    - Contact switches UBat

    E / 11111 x

    Contact potentialfree,

    - Contact switches UBat-

    - Transistor switches UBat-

    F / 11112 x

    PT100

    - Resistance sensor, Measuring range -50C +200C

    G / 11119 x

    PT1000

    - Resistance sensor, Measuring range -50C +200C

    H / 11120 x

    Thermo couple NiCrNi, Type K

    Measuring range 0C +1000C

    I / 11121 x

    Voltage 0 5 V DC J / 11122 x

    Voltage 0 10 V DC K / 11123 x

    Voltage 0 30 V DC (discontinued) L / 11124 x

    Voltage 0 40 V DC T / 13142 xRacor/Parker water level sensor M / 10893 x

  • 8/8/2019 2 Boening en SAS

    9/83

    AHD-SAS 15 Data station

    Connection schemes

    for analog and binary sensors withcorresponding analog input module

  • 8/8/2019 2 Boening en SAS

    10/83

    AHD-SAS 15 Data station

    Connection schemes

    for analog and binary sensors withcorresponding analog input module

  • 8/8/2019 2 Boening en SAS

    11/83

    AHD-SAS 15 Data station

    Connection schemes

    for analog and binary sensors withcorresponding analog input module

  • 8/8/2019 2 Boening en SAS

    12/83

    AHD-SAS 15 Data station

    Connection schemes

    for analog and binary sensors withcorresponding analog input module

  • 8/8/2019 2 Boening en SAS

    13/83

    AHD-SAS 15 Data station

    Applicable as autarkic

    alarm and monitoring system

    1 Horn relay output

    1 Common alarm relay output

    2 free configurable relay outputs

    1 Acknowledgement input for external alarm

    acknowledgement

    System operates independently

    from other components

    Alarm signaling also at complete shutdownof system bus

    Local alarm indications by LEDs

  • 8/8/2019 2 Boening en SAS

    14/83

    AHD-SAS 15 Data station

    Configuration via PC Software

    Measuring point text (2 languages applied)

    Unit

    Standardization (i.e. Tank curve)

    Indication range / Validity range Wire breakage monitoring

    Alarm signaling / Alarm limits

    (min./max. Alarm, Warning)

    Alarm delay

    Alarm suppression

    Filter settings (rising/ trailing edge)

    Configuration via CAN-BUS-Line

  • 8/8/2019 2 Boening en SAS

    15/83

    AHD-SAS 15 Data station

    Internal measuring value processing

    All acquired measuring data are internally

    processed and standardized.

    On demand, special characteristic curvescan be applied by configuration, i.e. for non

    linear sensors or tank content

    measurements.

    Additionally it is possible to create virtual

    channels, whose resulting values arecalculated from multiple physical sensors.

    A virtual channel may be used e.g. for

    calculation of total fuel reserve by

    summation of several tank contents or

    mean value calculation of exhaust gas

    temperatures.

  • 8/8/2019 2 Boening en SAS

    16/83

    AHD-SAS 15 Data station

    Integrated alarm memory

    An integrated alarm memory may record

    up to 10,000 messages within a data

    station AHD-SAS 15.

    These may be warning, alarm, sensorfault or also status messages.

    The storage considers here all locally

    arising events and stores them with date,

    time, duration and acknowledgement

    state. The readout of memory can be

    performed locally via existing RS232interface.

    (Readout via CAN-BUS in progress).

  • 8/8/2019 2 Boening en SAS

    17/83

    Alarm & Monitoring Systems

    Data stations

    AHD-SAS 15

    AHD-PS 47 / AHD-PS 30 / AHD-PS 15

    AHD-R 101

    AHD 882

  • 8/8/2019 2 Boening en SAS

    18/83

    AHD-PS 47 Binary data station

    47 binary inputs

    3 serial

    outputs

  • 8/8/2019 2 Boening en SAS

    19/83

    AHD-PS 15 / AHD-PS 30 Binary data stations

    15 binary inputs

    3 serialoutputs

    3 serialoutputs

    30 binary inputs

  • 8/8/2019 2 Boening en SAS

    20/83

    AHD-PS 47 / PS 30 / PS 15 Binary data station

    For acquisition of binary signals

    (potentialfree contacts resp. system

    voltages switched by contacts or

    transistors etc.)

    In- and outputs via optocoupler

    Conversion into serial signal for further

    processing (i.e. by AHD-SAS 15)

    Serial data transmission up to 1000m

    Installation next to sensors possible

    Minimized cabling demands

  • 8/8/2019 2 Boening en SAS

    21/83

    AHD-PS 47 / PS 30 / PS 15 Binary data station

    Test button for checkof short to

    earth/ground

    LED Status indications

  • 8/8/2019 2 Boening en SAS

    22/83

    AHD-PS 47 / PS 30 / PS 15 Binary data station

    Connection of binary inputs1) Potential free contacts, Normally Open (NO) and

    Normally Closed (NC).

    2) Potential free contacts, Normally Open (NO) and

    Normally Closed (NC), with combined common pole.

    3) Transistor inputs, minus-switching, with common

    minus potential. Those sensors are switched like

    contacts. The minus terminal of input (N) remains

    unconnected.

    4) Potential free contacts, Normally Open (NO) andNormally Closed (NC), with combined common pole

    with minus potential. The minus terminal of input (N)

    remains unconnected.

    5) Potential free contacts, Normally Open (NO) and

    Normally Closed (NC), with combined common pole

    with plus potential. The input terminals (P + N) are

    shorted to allow measurement of change of potential

    in case of switching of contact.

    6) Transistor inputs, plus-switching, with common plus

    potential. The input terminals (P + N) are shorted to

    allow measurement of change of potential in case ofswitching of transistor.

  • 8/8/2019 2 Boening en SAS

    23/83

  • 8/8/2019 2 Boening en SAS

    24/83

    AHD-R 101 Relay station

    15 potentialfree

    change-over contacts

    2 serial

    inputs

  • 8/8/2019 2 Boening en SAS

    25/83

    AHD-R 101 Relay station

    Serial-Parallel-Data Conversion

    Serial data transmission up to1000m

    (i.e. from AHD-SAS 15)

    Status-LED indications

    14 relay outputs free configurable

    Output No. 15 used for device failure

    signaling

  • 8/8/2019 2 Boening en SAS

    26/83

    Alarm & Monitoring Systeme

    Data stations

    AHD-SAS 15

    AHD-PS 47 / AHD-PS 30 / AHD-PS 15

    AHD-R 101

    AHD 882

  • 8/8/2019 2 Boening en SAS

    27/83

    AHD 882 Central unit

    CAN18 serialinputs

    16 serialoutputs

    5 Group relay outputs

    1 Configurable alarm relay output

    1 Horn relay output

    1 Input for audible alarm acknowledgement

    1 Input for visual alarm acknowledgement

  • 8/8/2019 2 Boening en SAS

    28/83

  • 8/8/2019 2 Boening en SAS

    29/83

    AHD 882 Central unit

    Integrated alarm memory

    Storage of last 10,000 messages with

    date/time

    Distinguishing between status and alarm

    messages as well as Switch-On and

    Switch-Off messages

    Memory complete warning

    If memory is filled up and a new alarm

    arises, the eldest stored alarm will be

    deleted and the new alarm is stored

    (First-in/first-out-principle).

  • 8/8/2019 2 Boening en SAS

    30/83

    AHD 882 Central unit

    Output for alarm and event data

    Serial output for

    Alarm printer

    Laptop / PC

    LCD Display with serial input

    Voyage Data Recorder VDR

    RS232 or RS422 selectable

    Activation via DIP switch

    RS232

    RS422

  • 8/8/2019 2 Boening en SAS

    31/83

    AHD 882 Central unit

    Configuration via PC Software

    Configuration

    via CAN-BUS-Line

  • 8/8/2019 2 Boening en SAS

    32/83

    Alarm & Monitoring Systems

    Data converter

    AHD-UIC

    AHD-UCC

  • 8/8/2019 2 Boening en SAS

    33/83

    AHD-UIC Interface converter

    Data communication with externalsystem

    CAN

    3 interfaces: 1 x RS232, 2 x

    RS485

    AHD-SAS CAN bus network

  • 8/8/2019 2 Boening en SAS

    34/83

  • 8/8/2019 2 Boening en SAS

    35/83

    Alarm & Monitoring Systems

    Data converter

    AHD-UIC

    AHD-UCC

  • 8/8/2019 2 Boening en SAS

    36/83

    AHD-UCC Universal CAN converter

    Data communication

    with external system

    CAN

    AHD-SAS CAN bus network

    CAN

  • 8/8/2019 2 Boening en SAS

    37/83

    AHD-UCC Universal CAN converter

    Data acquisition from external

    systemsLogging of defined data on CAN bus of

    external system with data conversion to Bning

    AHD-SAS CAN bus network

    CAN bus interfaces galvanically isolated

    Conversion of data protocols of external

    systems

    NMEA 2000

    SAE J1939

    Protocols of engine manufacturers

    (i.e. Caterpillar, Cummins etc.)

    Applicable as repeater unit with extended cable

    lenghts within AHD-SAS CAN bus network

  • 8/8/2019 2 Boening en SAS

    38/83

    Alarm & Monitoring Systems

    Displays with integrated PC, Monitors

    AHD 1019 M

    AHD 1015 TC/MTC

    AHD 919

    AHD 915 TC

  • 8/8/2019 2 Boening en SAS

    39/83

    AHD 1019 M Colour display

    19 LED backlight LCD colour display

    with integrated PC (Panel computer)

    High resolution display

    (SXGA, 1280(H) x 1024(V) Pixel, 1000

    cd/m2)

    Readable even at solar radiation

    Multiple visualization pages with project-specific resp. standard design

    Integrated PC with Pentium Mobile 1.7 GHz

    processor, 1 GB RAM/1 GB flash disk

    Innovative operation concept with operation

    units connected to control CAN (CAN5)

    Robust design, no moveable parts Automatic control of backlight illumination

    Approved for display of Radar and ECDIS

    sea chart images (ECDIS push button)

  • 8/8/2019 2 Boening en SAS

    40/83

    AHD 1019 M Colour display

    Rear view: Interfaces:

    Power supply 24 V DC(9 32 V DC)

    5 x CAN Bus

    CAN1: Engine 1

    CAN2: Engine 2

    CAN3: AHD-SAS network

    CAN4: AHD-SAS network(redundant)

    CAN5: Control CAN operation

    1 x RS232

    1 x LAN

    2 x USB 2.0

    Opt. In (4x Optocoupler input)Relay Out (2x Relay output)

    1 x Video In (BNC), PAL 50 Hz

    1 x DVI In (DVI-D, Dual Link)

    1 x VGA In

  • 8/8/2019 2 Boening en SAS

    41/83

    Alarm & Monitoring Systems

    Displays with integrated PC, Monitors

    AHD 1019 M

    AHD 1015 TC/MTC

    AHD 919

    AHD 915 TC

  • 8/8/2019 2 Boening en SAS

    42/83

  • 8/8/2019 2 Boening en SAS

    43/83

    AHD 1015 TC/MTC Colour display

    Rear view (AHD 1015 MTC): Interfaces:

    Power supply 24 V DC(9 32 V DC)

    5 x CAN Bus

    CAN1: Engine 1

    CAN2: Engine 2

    CAN3: AHD-SAS network

    CAN4: AHD-SAS network(redundant)

    CAN5: Control CAN operation

    1 x RS232

    1 x LAN

    2 x USB 2.0

    Opt. In (4x Optocoupler input)Relay Out (2x Relay output)

    Only with type MTC:

    1 x Video In (BNC), PAL 50 Hz

    1 x DVI In (DVI-D, Dual Link)

    1 x VGA In

  • 8/8/2019 2 Boening en SAS

    44/83

    Visualisation pages (examples)

    Main page Tanks

  • 8/8/2019 2 Boening en SAS

    45/83

    Visualisation pages (examples)

    Bilges Navigation Lights

  • 8/8/2019 2 Boening en SAS

    46/83

    Visualisation pages (examples)

    Power Engine analog

  • 8/8/2019 2 Boening en SAS

    47/83

  • 8/8/2019 2 Boening en SAS

    48/83

    Visualisation pages (examples)

    Events Measuring Points

  • 8/8/2019 2 Boening en SAS

    49/83

    Visualisation pages (examples)

    Settings

  • 8/8/2019 2 Boening en SAS

    50/83

    Alarm & Monitoring Systems

    Displays with integrated PC, Monitors

    AHD 1019 M

    AHD 1015 TC/MTC

    AHD 919

    AHD 915 TC

    AHD C l i

  • 8/8/2019 2 Boening en SAS

    51/83

    AHD 919 Colour monitor

    19 LCD colour monitor

    High resolution display

    (SXGA, 1280(H) x 1024(V) Pixel, 1000

    cd/m2)

    Readable even at solar radiation

    Approved for display of Radar and ECDISsea chart images (ECDIS push button)

    Video input

    Source selection by operating panels via

    control CAN

    Robust design, no moveable parts

    Automatic control of backlight illumination

  • 8/8/2019 2 Boening en SAS

    52/83

    Al & M i i S

  • 8/8/2019 2 Boening en SAS

    53/83

    Alarm & Monitoring Systems

    Displays with integrated PC, Monitors

    AHD 1019 M

    AHD 1015 TC/MTC

    AHD 919

    AHD 915 TC

  • 8/8/2019 2 Boening en SAS

    54/83

    AHD 915 C l it

  • 8/8/2019 2 Boening en SAS

    55/83

    AHD 915 Colour monitor

    Rear view (AHD 915): Interfaces:

    Power supply 24 V DC(9 32 V DC)

    1 x CAN Bus

    (Control CAN operation)

    1 x RS232

    Opt. In (4x Optocoupler input)

    Relay Out (2x Relay output)Touch Out

    1 x Video In (BNC), PAL 50 Hz

    1 x DVI In (DVI-D, Dual Link)

    1 x VGA In

    Al & M it i S t

  • 8/8/2019 2 Boening en SAS

    56/83

    Alarm & Monitoring Systems

    Display and Control Units

    AHD 651

    AHD 880 TC

    Kompakt EDA 47

    Accessories

    AHD 650 R

    AHD 651 C l di l

  • 8/8/2019 2 Boening en SAS

    57/83

    AHD 651 Colour display

    Graphic LCD colour display

    with 6.5 screen diagonal

    Transflective display for best readability even at solar radiation

    Front glass anti-reflection coated

    Degree of protection IP 67 (Front)

    Automatic dimming control of backlight illumination

    AHD 651 Colour display

  • 8/8/2019 2 Boening en SAS

    58/83

    AHD 651 Colour display

    Individual graphical or tabular page design

    multiple graphical presentation elements selectable

    (Icons, bar graph indicator, round gauges etc.)

    Integration of images and logos on max. 17 pages

    AHD 651 Colour display

  • 8/8/2019 2 Boening en SAS

    59/83

    AHD 651 Colour display

    Alarm page

    Integrated alarm buzzer; tabular alarm page

    Alarm indication with clear text incl. status, date and time

    AHD 651 Colour display

  • 8/8/2019 2 Boening en SAS

    60/83

    AHD 651 Colour display

    Configuration page

    Two languages selectable (Cyrillic also available)

    Switching of unit system

    Indication of CAN ID and setting of time

    Long time keypress

    AHD 651 Colour display

  • 8/8/2019 2 Boening en SAS

    61/83

    AHD 651 Colour display

    Service page

    Indication of all monitored measuring points within the ship alarm system

    tabular form; english language

    Version information of software

    Firmware / projectspec. graphic page software / projectspec. configuration softwa

    AHD 651 Colour display

  • 8/8/2019 2 Boening en SAS

    62/83

    AHD 651 Colour display

    AHD 651 Farbdisplay

  • 8/8/2019 2 Boening en SAS

    63/83

    AHD 651 Farbdisplay

    Alarm & Monitoring Systems

  • 8/8/2019 2 Boening en SAS

    64/83

    Alarm & Monitoring Systems

    Display and Control Units

    AHD 651

    AHD 880 TC

    Kompakt EDA 47

    Accessories

    AHD 650 R

  • 8/8/2019 2 Boening en SAS

    65/83

  • 8/8/2019 2 Boening en SAS

    66/83

    AHD 880 TC Colour display

  • 8/8/2019 2 Boening en SAS

    67/83

    AHD 880 TC Colour display

    Alarm page

    Integrated alarm buzzer; tabular alarm page

    Alarm indication with clear text incl. status, date and time

    AHD 880 TC Colour display

  • 8/8/2019 2 Boening en SAS

    68/83

    AHD 880 TC Colour display

    Configuration pages

    Two languages selectable

    Switching of unit system

    Indication of CAN ID and setting of date and time

    Min/Max. brightness settings of displays adjustable

  • 8/8/2019 2 Boening en SAS

    69/83

    AHD 880 TC Colour display

  • 8/8/2019 2 Boening en SAS

    70/83

    AHD 880 TC Colour display

    Video input

    Composite Video; BNC socket - PAL 50Hz

    AHD 880 TC Colour display

  • 8/8/2019 2 Boening en SAS

    71/83

    AHD 880 TC Colour display

    AHD 880 TC Colour display

  • 8/8/2019 2 Boening en SAS

    72/83

    AHD 880 TC Colour display

    Comparison of colour displays

  • 8/8/2019 2 Boening en SAS

    73/83

    Comparison of colour displays

  • 8/8/2019 2 Boening en SAS

    74/83

    AHD 650 R Remote control

  • 8/8/2019 2 Boening en SAS

    75/83

    AHD 650 R Remote control

    Remote control for colour displays

    5 integrated operating keys for remote control of colour displays

    (except power on/off function)

    Degree of protection IP 67 (Front)

    Connection via 8-pole connection cable (both endings plugable)

    applicable for AHD 651 and AHD 880 TC

    AHD 650 R Remote control

  • 8/8/2019 2 Boening en SAS

    76/83

    650 e ote co t o

    AHD 650 R Remote control

  • 8/8/2019 2 Boening en SAS

    77/83

    Alarm & Monitoring Systems

  • 8/8/2019 2 Boening en SAS

    78/83

    g y

    Display and Control Units

    AHD 651

    AHD 880 TC

    Kompakt EDA 47

    Accessories

    AHD 650 R

    Kompakt EDA 47

  • 8/8/2019 2 Boening en SAS

    79/83

    p

    Compact alarm and

    display system

    48 illuminated and automatically dimmed text fields

    Unused fields shaded deep black

    Free inscription on common film negative; Block LED colours red, green, yellow

    Integrated alarm buzzer

    Configuration of EEPROM (Type 28C64) by programming device Dataman S4"

    2 serial

    inputs

    3 serialoutputs

    Kompakt EDA 47

  • 8/8/2019 2 Boening en SAS

    80/83

    p

    Kompakt EDA 47

  • 8/8/2019 2 Boening en SAS

    81/83

    p

    Kompakt EDA 47

  • 8/8/2019 2 Boening en SAS

    82/83

    p

    Audible acknowledgement (Hornquit)

    Visual acknowledgement

    Lamp test

    External operating elements required

    Kompakt EDA 47

  • 8/8/2019 2 Boening en SAS

    83/83

    On- and Off-delay 1-99 sec.

    Contact type (NC/NO)

    Alarm suppression

    serial group outputs

    Configuration