zip system® sheathing submittal form - huber …€¦ · when huber’s zip system sheathing is...

20
ZIP SYSTEM® SHEATHING SUBMITTAL FORM Submitted to: Job Name: Submitted by: Date: Product: 7/16” 1/2” 5/8” 5/8” T&G Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800-933-9220. www.ZIPSystem.com . www.huberarchitectlibrary.com Technical Service Hotline: 800.933.9220 ext. 2716

Upload: others

Post on 20-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® SHEATHING SUBMITTAL FORM

Submitted to:

Job Name:

Submitted by:

Date:

Product: 7/16” 1/2” 5/8” 5/8” T&G

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262

800-933-9220. www.ZIPSystem.com . www.huberarchitectlibrary.comTechnical Service Hotline: 800.933.9220 ext. 2716

Page 2: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® SHEATHING

MANUFACTURER Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220 • Technical Service: 800.933.9220 x2716 ZIPSystem.com • HuberArchitectLibrary.com

BASIC USE AND APPLICATIONS ZIP System Roof and Wall sheathing panels are oriented strand board (OSB), wood structural panels with built-in protective overlays that eliminate the need for building wrap or roofing felt. Install the panels, tape the seams with Huber’s ZIP System tape, and the building is rough dried-in. A wide range of roof coverings and wall claddings can be installed directly over ZIP System sheathing.

When used on a wall, ZIP System sheathing functions as a combination wall sheathing, code-recognized water-resistive, and air barrier. The sheathing panel seams are sealed with ZIP System tape, protecting the wall from water intrusion.

When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof coverings system requiring multiple layers of water-resistive barriers or underlayment, ZIP System is intended to replace on the first layer.

ZIP System sheathing uses a tough, phenolic resign-impregnated overlay to provide permanent weather resistance, in contact with a proprietary seam tape that has been extensively tested for long-term adhesion and flexibility. This combination meets performance requirements for Grade D weather-resistive barriers in accordance with ICC Acceptance Criteria AC38.

ZIP System sheathing may be used for roofs and walls in Type V construction, in Type III construction as roof sheathing only, and other construction permitted under the International Residential Code.

AVAILABLE SIZES ZIP System Roof and Wall sheathing panels are available in 4’ x 8’ sheets with self-spacing edge profiles and tongue and groove edge profile (5/8 only). ZIP System panels are Exposure 1 rated and are available in the following span ratings and performance categories.

• 24/16, Structural 1, 7/16 PERF CAT (4’ x 8, 9 and 10’)*

• 32/16, Structural 1, 1/2 PERF CAT

• 40/20, Structural 1, 5/8 PERF CAT

Longer length panels are available for wall applications. Third party independent testing for ZIP System Roof and Wall sheathing is conducted by Timberco, Inc. (TECO).

ZIP System Benefits Superior Moisture Resistance

Continuous vapor permeable moisture barrier that blocks out liquid water but still allows walls to dry out

Ease of Installation No more delays because of felt or building wraps blowing off

Energy Efficient Code-recognized built in weather and air barrier

LIMITATIONS When used as roof sheathing, ZIP System sheathing is limited to

roofs with slopes of 2:12 (16.67 percent) or greater. Felt

underlayment is not required on the roof. In roof covering systems

requiring multiple layers of underlayment, ZIP System sheathing is

intended to replace only the first layer. In wall covering systems

requiring multiple layers of water-resistive barriers, ZIP System

sheathing is intended to replace only the first layer.

ZIP System sheathing should not be used with adhesively-attached

EIFS, but can be used with mechanically attached EIFS. Avoid

exposing ZIP System sheathing for more than 180 days.

SUSTAINABLE DESIGN CONTRIBUTIONS

• Low-Emitting Material: No added urea formaldehyde

• Sustainable Forestry Initiative Certified Wood: Harvested, transported, manufactured, and distributed utilizing sustainable practices

• Renewable Forest Resources: Composed of primarily young growth bio-based resources

• Regional Materials: Made in the United Sates at one of our 4regional manufacturing facilities: Broken Bow, OK; Commerce, GA; Crystal Hill, VA; Easton, ME; Spring City, TN; and Arbec, QC

Page 3: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

*Note: 4’ x 8’ 7/16” ZIP System “Structural 1” panels are not available in all areas of the country. Please check with your local supplier for availability in your area.

POTENTIAL LEED CREDIT CONTRIBUTIONS

• Credit IEQ 4.4 Low-Emitting Materials, Composite Wood and Agrifiber: AdvanTech contains no added urea formaldehyde

• Credit MR 5.1 or 5.2 Regional Materials: Materials harvested,processed, and manufactured within 500 miles of project site.

• Credit MR 2.2 Environmentally Preferable Products – Local Production (LEED for Homes)

• EA 3 Air Infiltration – Meet air leakage requirements

SUBSTRATE Before beginning installation, verify wood wall framing is properly spaced and aligned to continuously support panel edges.

PANEL INSTALLATION Install ZIP System sheathing in accordance with:

• ZIP System Sheathing Installation Manual

• ICC-ES ESR-1473

• ICC-ES ESR-1474

• Requirements of authorities having jurisdiction

When used as roof sheathing, install panels with moisture barrier surface facing out, with long edge perpendicular to framing members, and with short edges fully supported. Stagger short edge seams. Long edges are self-spacing; 4-foot panel edges should be spaced manually approximately 1/8-inch (3 mm) apart.

When used as wall sheathing, install panels positioned with the water-resistive barrier facing out. The panels may be installed with the long side of the panel oriented either horizontally or vertically to the framing members. Walls that are designed to resist lateral shear forces and sheathed with wood structural panels typically require solid framing or blocking behind all panel edges. Long edges are self-spacing; 4-foot panel edges should be manually spaced approximately 1/8-in (3 mm) apart.

Fasteners: Install fasteners approved by applicable building codes. Install fasteners 3/8-inch (9.5 mm) from panel edges. Space fasteners 6-inches (152 mm) on centers on supported panel ends and 12-inches (305 mm) on center at intermediate supports unless otherwise specified. ZIP System panels have a printed fastening guide for 16-inch (406 mm) and 24-inch (610 mm) on center fasteners locations.

Tape Installation: Install ZIP System tape in accordance with manufacturer’s written instructions as seams, openings, and penetrations. Install windows and window flashing in accordance with window manufacturer’s written instructions. Details of installation recommendations are available in AutoCAD and PDF formats at ZIPSystem.com or HuberArchitectLibrary.com.

STORAGE AND HANDLING Store and handle products according to manufacturer’s written recommendations. Support panel bundles off the ground. Cover stored panels with weatherproof protective material; allow sides of protective material to remain loose to ensure adequate air circulation. In high-moisture conditions, cut bundle banding to prevent edge damage to panels. Factory applied packaging is intended only for protection during transit.

AVAILABILITY Huber Engineered Wood’s ZIP System Roof and Wall sheathing panels are manufactured at multiple locations in the U.S. They are available through distributors nationwide. Visit ZIPSystem.com or contact Huber Engineered Woods for a retailer near you.

WARRANTY ZIP System Roof and Wall sheathing is furnished with a 30-year system warranty as well as a 30-year warranty against manufacturing defects. Visit ZIPSystem.com for limitations and restrictions.

NOTES AND LIMITATIONS

• Do not use on roof with slopes less than 2:12

• Do not install ZIP System tape in temperatures less than 0° F

• Roof panels edge clips are only required with 7/16 inch thick ZIP System sheathing on supports spaced greater than 16-inches oc.Panel edge clips approved to be used with ZIP System Sheathing are: Simpson Strong-Tie®, PSCA, PSCL and Tamlyn™ PCS models

TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications is available through Huber Engineered Woods. Please visit ZIPSystem.com or call 800.933.9220 EXT 2716 to speak to a technical representative.

AVAILABLE RESOURCES Section 06 16 13 SHEATHING guide specifications ZIP System Roof and Wall Sheathing products in CSI 3-part format is available in MasterSpec®, ARCAT.com, BSD SpecLink®, at ZIPSystem.com, and HuberArchitectLibrary.com.

ZIP System Sheathing Performance Properties

Exposure Durability Classification

DOC PS 2 Exposure 1

Panel Grade DOC PS 2 Structural 1*

Moisture Barrier AC38 Grade D WRB

Water Penetration ASTM E331 Passed

Vapor Transmission ASTM E96-B (panel overlay)

12-16 perms

Air Barrier Assembly ASTM E2357 0.037 L/(s*m2)

Air Barrier Material ASTM E2178 0.0016 L/(s*m2) @300 Pa

Wind Driven Rain TAS 100 (at 100 mph) Passed

Drainage Efficiency ASTM E 2273 98%

© 2015 Huber Engineered Woods LLC. AdvanTech® is a registered trademark of

Huber Engineered Woods LLC. Huber is a registration trademark of J.M. Huber

Corporation. HUB-9006 11/18

Page 4: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof
Page 5: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® LIQUID FLASH SUBMITTAL FORM 

Submitted to:       

Job Name: 

Submitted by: 

Date: 

Product:     20 oz. Sausage Pack    29 oz. Cartridge  

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 

800‐933‐9220. www.ZIPSystem.com . www.huberarchitectlibrary.com Technical Service Hotline: 800.933.9220 ext. 2716 

Page 6: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® LIQUID FLASHING 

MANUFACTURER  Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220  • Technical Service: 800.933.9220 x2716 ZIPSystem.com  • HuberArchitectLibrary.com  

BASIC USE AND APPLICATIONS ZIP System Liquid Flash is a liquid‐applied flashing membrane use in combination with ZIP System Sheathing to create a continuous air/moisture barrier. ZIP System Liquid Flash  is compatible with ZIP  System  Sheathing’s  phenolic  resin‐impregnated  protective facing,  and  works  in  conjunction  with  ZIP  System  Tape  to permanently  flash  and  seal  all building penetrations  and panel seams. 

ZIP  System  Liquid  Flash  loads  into  a  professional  sausage‐pack caulking gun and  is easily applied  to  form a  resilient,  seamless membrane. Intended for use on both commercial and residential buildings,  ZIP  System  Liquid  Flash  provides  great  versatility  in sealing panel seams and irregular, curved, or hard‐to‐flash areas such as a curved window and door rough openings, through‐wall pipe, conduit, and vent penetrations, and terminations of metal flashings.  

ZIP System Liquid Flash  transforms ZIP System sheathing  into a seamless  protective  barrier,  providing  a  superior  airtight  and watertight seal  that resists harsh elements. The combination of ZIP System Sheathing and ZIP System Tape or ZIP System Liquid Flash eliminates  the need  for a separate application of building wrap or roofing  felt.  Install the sheathing panels, seal the seam with  ZIP  System  Tape  or  ZIP  System  Liquid  Flash,  seal  the penetrations with  ZIP  System  Liquid  Flash,  and  the  building  is permanently weatherized.  

ZIP System Liquid Flash Allowable Exposure Period  180 Days 

Sealant Composition  Single component silyl‐terminated polyether (STPE) 

Surface and ambient Application Temperature 

Between 35 °F (2 °C) and 110 °F (43 °C) 

Compatibility   PVC, EPDM, concrete, masonry, structural sheathing, painted and unpainted metals, and glass 

ADVANTAGES ZIP  System  Liquid  Flash  is  specifically  formulated  for compatibility and durability as a component of the ZIP System air/moisture  barrier.  It  is  also  effective  in  similar  applications utilizing a wide range of sheathing and weather barrier products. Test  results  for  air/moisture  assemblies  utilizing  ZIP  System Liquid  Flash  as  a  component  demonstrate  its  effectiveness  in preventing air  infiltration and water penetration at vulnerable barrier  penetrations  of  vents,  piping,  and  conduits  as well  as transitions from sheathing to adjacent masonry construction.  

The result is a superior, reliable, durable seal. ZIP System Liquid Flash displays excellent  resistance  to deterioration  from aging and from weather exposure – a critical need for components of the  air/moisture  barrier  that  are  not  visible  and  readily renewable. In addition, its elongation accommodates the normal expansion and contraction found in wood construction.  

ZIP System Liquid Flash is easy to gun, spread, and tool in harsh and  demanding weather  conditions.  It  bonds  to  damp  or  dry surfaces and does not need a primer when bonding to the ZIP System panel surface.  It becomes opaque when  the minimum required thickness achieved, ensuring a good quality control and efficiency.  

SUSTAINABILITY  Contains no solvents or isocyanates

Complies  with  US  EPA  National  VOC  Standards  forArchitectural Control Measure for Architectural Coatings, 63FR 176:48848

Complies  with  California  Air  Resources  Board  (CARB)Suggested Control Measure for Architectural Coatings (SCM)

PACKAGING ZIP  System  Liquid  Flash  is  available  in 20 oz.  (0.59  L)  sausage packs and standard 29 oz. (0.86 L) caulk tubes.  

Page 7: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

  

NOTES AND LIMITATIONS ZIP System Liquid Flash is classified as a Class A building material; however,  it  is  not  recognized  for  use where  non‐combustible sealants are required.   

Recommended for use in buildings of Class V construction and construction permitted under the IRC  

Not  considered a  substitute  for  self‐adhering  ice and water barrier applications in roofing systems; where such materials are required, proved them in addition to application of Liquid Flash 

Not recommended for use as a structural sealant or adhesive, a  through‐wall  flashing  or  for  use  below  grade  or  where continuously immersed in water 

Compatible with most urethane, silicone, and acrylic sealants and coatings   

SUBSTRATE Ensure that substrate is surface dry and free of frost, dust, dirt, loose  fasteners,  and  protrusions.  Apply  Liquid  Flash  when ambient air and substrate are above 35 °F (2 °C) and below 110 °F (43 °C). Refer  to  manufacturer’s  instructions  for  application  of  ZIP System  Panels  and  ZIP  System  Tape.  Prime  or  lightly  scuff portions  of  ZIP  System  Tape  application  that  will  come  into contact with Liquid Flash.  

 INSTALLATION  Refer  to  manufacture’s  ZIP  System  Liquid  Flash  Installation Manual for instructions for application. Fill gaps exceeding 1/4" (6 mm) with  approved  backing material  prior  to  application. Comply with detailed instructions for flashing the following:  

Flanged and brick mould windows 

Pipe, conduit, and electrical boxes  Vent hoods  Mechanical flashing transitions   

COVERAGE AND CURING A  20  oz.  (0.59  L)  Liquid  Flashing  sausage  pack  covers approximately 50  linear feet (15 m) of panel seam or 20  linear feet (6 m) of window flashing, the 29 oz. (0.86 L) cartridge covers 70  linear  feet  (20 m) of panel  seam or 29  (8.5 m) of window flashing, and the 10 oz. (0.30 L) cartridge covers approximately 25  linear feet (7.5 m) of panel seam or 10 of window flashing. Coverage rates assume an installed thickness of 12‐15 mils in a wall  constructed  of  2x4  framing.  Liquid  Flash  skins within  30 minutes  and  cures within  4  hours  at  70  °F  (21  °C)  and  50% relative humidity;  low  temperatures and  low relative humidity slow curing time.  

 STORAGE AND HANDLING  Store  ZIP  System  Liquid  Flash  in  the  original  packaging  at temperature not  to exceed 90  °F  (32  °C).  Store  in  a  cool, dry place.  

 When  stored  as  recommended  in  its  original  unopened container the typical shelf  life for ZIP System Liquid Flash  is 12 months from the date of manufacture.   

 

 AVAILABILITY Huber Engineered Wood’s ZIP System  Liquid Flash  is available through distributors nationwide. Visit ZIPSystem.com or contact Huber Engineered Woods for a retailer near you. 

 WARRANTY  ZIP  System  Liquid  Flash  is  furnished  with  a  30‐year  system warranty  when  used  with  ZIP  System  Sheathing.  See ZIPSystem.com for details. 

 TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications is available  through  Huber  Engineered  Woods.  Please  visit ZIPSystem.com  or  call  800.933.9220  x2716  to  speak  to  a technical representative or [email protected].  

 AVAILABLE RESOURCES  Section 06 16 00 SHEATHING and Section 06 16 13 INSULATING SHEATHING guide specifications for   ZIP System Roof and Wall Sheathing  products  in  CSI  3‐part  format  is  available  at ZIPSystem.com or HuberArchitectLibrary.com.  

 

ZIP System Liquid Flash Physical Properties  Total Solids  

  99 percent 

VOC Content  

  30 g/L maximum 

Hardness, Shore A  

ASTM C661  35‐45  

Tensile Strength   

ASTM D412  >150 psi (>1034 kPA) 

Elongation at Break  

ASTM D412  >350 percent 

Flame Spread  

ASTM E84  0 

Smoke Developed  

ASTM E84  15 

Air Leakage, as part of tested assembly 

ASTM E2357  <0.04 cfm/sq. ft. at 1.57 lb/ sq. ft. (0.2 L/s*sq m at 75 Pa) 

Water Vapor Transmission ASTM E96  21 perms 

Water Penetration, as part of tested assembly   

ASTM E331  Pass at 2.86 lb/sq. ft. (137 Pa) 

Wind Driven Rain  TAS‐100  Pass at 110 mph (177km/h) 

UV Exposure, 2000 hours  

ASTM G154  Pass 

Accelerated Weathering  

ASTM C793  Pass 

     © 2015 Huber Engineered Woods LLC. AdvanTech® is a registered trademark of Huber Engineered Woods LLC. Huber is a registration trademark of J.M. Huber Corporation.  HUB 9003 09/18  

Page 8: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

 

 

                  

Page 9: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® R-SHEATHING SUBMITTAL FORM

Submitted to:

Job Name:

Submitted by:

Date:

Product: R-3 (1”) R-6 (1-1/2”) R-9 (2”) R-12 (2-1/2”)

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262

800-933-9220. www.ZIPSystem.com . www.huberarchitectlibrary.comTechnical Service Hotline: 800.933.9220 ext. 2716

Page 10: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® R-SHEATHING

MANUFACTURER Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220 • Technical Service: 800.933.9220 x2716 ZIPSystem.com • HuberArchitectLibrary.com

BASIC USE AND APPLICATIONS ZIP System R-Sheathing insulating sheathing is a one-of-a-kind layered product engineered to insulate and protect wall assemblies in a single application. ZIP System R-Sheathing combines the strength, weather-resistive, and air barrier qualities of ZIP System Sheathing with the thermal resistance of polyisocyanurate foam insulation.

ZIP System R-Sheathing provides a combined R-value of 3.6, 6.6, 9.6 or 12.6 on the outside of wall framing in addition to wall cavity insulation. One panel delivers thermal, air, and moisture resistance, while providing strength and durability. ZIP System R-Sheathing, with its built-in protective overlay eliminates the need for building wrap. Install the panels, tape the seams with ZIP System tape, and the building is rough-dried in. A wide range of wall claddings install directly over ZIP System R-Sheathing to finish the exterior.

ZIP System R-Sheathing uses a tough, phenolic resin-impregnated overlay to provide permanent weather resistance along with a proprietary seam tape that is extensively tested for long-term adhesion and flexibility.

This material combination meets performance requirements for Grade D weather-resistive barriers in accordance with ICC Acceptance Criteria AC38. ZIP System R-Sheathing may be used for walls on buildings of Type V construction and other construction permitted under the International Residential Code.

AVAILABLE SIZES ZIP System R-Sheathing panels are available in nominal 4’ x 8’ sheets. The wood structural panel layer is approximately 47-15/16” x 95-7/8”, while the polisocyanurate foam bonded to the structural panel layer is sized at a full 48” x 96”. This allows for proper gapping between the wood panels, with a 1/16” to 1/8” foam overhang located on two of four panel edges to ensure tightly fitted insulation. Panels are available in the following thicknesses:

• Nominal 1” thick: 7/16” thick ZIP System panel plus 1/2” thickfoam with a combined R-value of 3.6

• Nominal 1-1/2” thick: 7/16” thick ZIP System panel plus 1” thickfoam with a combined R-value of 6.6

• Nominal 2” thick: 7/16” thick ZIP System panel plus 1-1/2” thickfoam with a combined R-value of 9.6

• Nominal 2-1/2” thick: 7/16” thick ZIP System panel plus 2” thickfoam with a combined R-value of 12.6

ZIP System Benefits Structure and Durability • Nail-able wood base

• Can be used to resist shear(see ESR-3373 for conditions)

Built-in Water Resistive Barrier

• Eliminates costly rework• Instant rough dry-in

Continuous Air Barrier • Reduces air leakage, protecting theR-value of the insulation

Continuous Exterior Insulation

• Increases thermal performance• Controls thermal bridging

Ease of Installation • All-in-one product eliminatesmultiple installations

SUSTAINABLE DESIGN CONTRIBUTIONS

• Low-Emitting Material: No added urea formaldehyde• Sustainable Forestry Initiative Certified Wood: Harvested,

transported, manufactured, and distributed utilizing sustainable practices

• Renewable Forest Resources: Composed of primarily young growthbio-based resources

• Regional Materials: Made in the United Sates at one of our 4regional manufacturing facilities: Commerce, GA; Broken Bow, OK;Crystal Hill, VA; and Easton, ME

Third party independent compliance testing of ZIP System RSheathing is by Timberco, Inc. (TECO).

Page 11: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

SUBSTRATE Before beginning installation, verify wood wall framing is properly spaced and aligned to continuously support panel edges. PANEL INSTALLATION Install ZIP System R-Sheathing in accordance with: • ZIP System R-Sheathing Installation Manual • ICC-ES ESR-3373 • Additional requirements of code official Install panels with moisture barrier surface facing out. Panels may be oriented vertically or horizontally. Refer to ZIP System R-Sheathing Installation Manual. TAPE INSTALLATION Install ZIP System tape in accordance with all manufacturer’s written instructions at panel seams, openings, and penetrations. Install windows and associated window flashings in accordance with all window manufacturer’s instructions. Details of installation recommendations are available in AutoCAD and PDF formats at ZIPSystem.com or HuberArchitectLibrary.com. STORAGE AND HANDLING Store and handle products according to manufacturer’s written recommendations. Support panel bundles off the ground. Cover stored panels with weatherproof protective material; allow sides of protective material to remain loose to assure adequate air circulation. In high-moisture conditions, cut bundle banding to prevent edge damage to panels. Factory applied packaging is intended only for protection during transit. Packaged units must be stored indoors or within a covered structure. Do not stack more than three units high. AVAILABILITY Huber Engineered Wood’s ZIP System R-Sheathing panels are manufactured at multiple locations in the U.S. They are available through distributors nationwide. Visit ZIPSystem.com or contact Huber Engineered Woods for a retailer near you. WARRANTY ZIP System R-Sheathing is furnished with a 30-year system warranty as well as a 30-year warranty against delamination and manufacturing defects, subject to published standard terms and condition. NOTES AND LIMITATIONS ZIP System R-Sheathing should be covered with a code-complying exterior wall cladding within 180 days of installation. ZIP System R-Sheathing can only be used structurally with wood framed construction. DO NOT use in roofs or structurally over light gauge metal framing. For systems requiring multiple layers of water-resistive barriers, ZIP System R-Sheathing is intended to replace only the first layer. ZIP System R-Sheathing should not be used with adhesively attached EIFS, but can be used with mechanically attached EIFS.

TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications is available through Huber Engineered Woods. Please visit ZIPSystem.com or call 800.933.9220 EXT 2716 to speak to a technical representative. AVAILABLE RESOURCES Section 06 16 13 INSULATING SHEATHING guide specifications for ZIP System R-Sheathing products in CSI 3-part format is available at ZIPSystem.com or HuberArchitectLibrary.com. ZIP System R Sheathing Foam Insulation Properties Dimensional Stability ASTM D2126 <2%

Compressive Strength

ASTM D1621 20-25 psi

Water Absorption ASTM C209 ASTM D2842

< 1% < 3.5%

Water Vapor Transmission ASTM E96 < 1.0perm

Flame Spread ASTM E84 40-60

Smoke Developed ASTM E84 50-170

ZIP System R Sheathing Performance Properties Thermal Resistance (R-value) ASTM C1289*

3.6@1” 6.6@1-1/2” 9.6@2” 12.6@2-1/2”

Water Resistance of Coatings

ASTM D2247 (for 14 day)

Passed

Water Vapor Transmission Panel Overlay

ASTM E96

12-16 perms

Water Penetration ASTM E331

Passed

Air Barrier Assembly ASTM E2357

0.037 L/(s*m2)

Air Barrier Material ASTM E2178

-0.0016 L/(s*m2)

Wind Driven Rain TAS 100 (at 100 mph)

Passed

Accelerated Weathering ASTM G154 Passed

*LTTR for foam, with R-value of 7/16” OSB per ASHRAE Handbook-Fundamentals. For additional performance and installation information: Refer to ZIP System R-Sheathing ICC-ES ESR-3373.

© 2015 Huber Engineered Woods LLC. AdvanTech® is a registered trademark of Huber Engineered Woods LLC. Huber is a registration trademark of J.M. Huber Corporation. HUB-9005 02/17

Page 12: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof
Page 13: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP® SYSTEM STRETCH TAPE SUBMITTAL FORM

Submitted to:

Job Name:

Submitted by:

Date:

Product: 6” ZIP System Stretch Tape 10” ZIP System Stretch Tape

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262

800-933-9220. www.ZIPSystem.com . www.huberarchitectlibrary.comTechnical Service Hotline: 800.933.9220 ext. 2716

Page 14: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM™ STRETCH TAPE

MANUFACTURER

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220 • Technical Service: 800.933.9220 x2716 ZIPSystem.com • HuberArchitectLibrary.com

BASIC USE AND APPLICATIONS ZIP System™ stretch tape is a code-recognized flashing tape that stretches and forms around irregular and difficult to seal areas like window rough openings, curved window heads, and wall and roof penetrations. It is UV radiation resistant and highly effective at sealing up the exterior building envelope. Unlike most other flashing tapes, ZIP System stretch tape is compatible with flexible PVC windows.

ZIP System stretch tape easily stretches to fit difficult to flash areas with a single piece without having to piece tape segments together. This avoids tape seams or joints. ZIP System stretch tape is made of a high-performance composite acrylic adhesive and a strong, yet stretchable, acrylic foam core. The tape conforms to challenging applications and locks out moisture over mismatched surfaces when correctly applied. ZIP System stretch tape can be pulled up and reapplied for easy, fast, and hassle-free installation that provides a tight seal against weather intrusion.

ZIP System stretch tape can be used for a wide range of applications including:

• Window rough opening sill pans.

• Wall penetrations

• Curved window heads

• Cantilevered beams

ADVANTAGES ZIP System stretch tape is a multi-purpose acrylic tape with a robust and aggressive acrylic adhesive. The intertwined polymer chains provide excellent internal strength and durability. The tape’s advanced acrylic adhesive is made of highly polar molecules; the resulting attraction pulls the tape to the ZIP System® panel. This helps the tape wet out and flow into panel ridges and produce a weather tight seal. The strong, yet stretchable, acrylic foam core allows for continuous single-piece flashing around pipes, beams, rough openings and other difficult to flash applications. The ZIP System stretch tape satisfies the requirements of AC148 and AAMA 711-13 as represented in IAPMO ER-365.

The use of ZIP System stretch tape as flashing material is recognized for use on Type V construction under the IBC and non-fire-resistance-rated construction under the IBC and IRC.

ZIP System™ Stretch Tape Maximum Exposure Time

180 Days

Adhesive Type Acrylic

Installation Temperature Range

0 °F – 120 °F

Compatibility Compatible with flexible PVC used in vinyl windows

Tensile Strength 225 psi

Elongation 800-1200%

Code Acceptance IRC and IBC compliance recognized by IAPMO ER-365

Performance Standard AAMA 711-13 compliant

SIZE ZIP System stretch tape is available in 75 ft (22.8 m) long rolls in a 6-inch (152 mm) and 10-inch (254 mm) roll width, is 42 mils thick and is packaged with a release liner.

SUBSTRATE Prior to application, ensure that the surface to be taped is dry and free of frost, dust, dirt, loose fasteners, and other protrusions. Apply tape when ambient air and substrate are above 0 °F (-18 °C).

TAPE INSTALLATION Refer to installation instructions on huberwood.com or huberarchitectlibrary.com for detailed instructions and illustrations for application of ZIP System Stretch Tape to sheathing, flanged windows, brick mould windows, penetrations, and openings. Apply tape as additionally prescribed in IAPMO ER-365. Tape should be covered with a code-compliant roof or wall covering within 180 days of installation. ZIP System stretch tape is a pressure sensitive tape that must be rolled in (ZIP System Tape roller or similar) to achieve maximum bond to the panel.

Page 15: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

WINDOWS AND PENETRATIONS

Apply tape at wall openings and sheathing penetrations in manner described in window or door manufacturer’s written instructions. Details of installation recommendations are available in AutoCAD or PDF formats at ZIPSystem.com or HuberArchitectLibrary.com

STORAGE AND HANDLING Store ZIP System stretch tape in the original packaging at a temperature not to exceed 90 °F (32 °C). Store in a clean, dry place.

When stored as recommended in its original unopened container the typical shelf life for ZIP System stretch tape is 9 months from the date of manufacture.

WARRANTY ZIP System stretch tape is furnished with a 30-year limited system warranty when used with ZIP System Sheathing. See ZIPSystem.com for details.

AVAILABILITY Huber Engineered Wood’s ZIP System stretch tape is available through a vast network of distributors. Visit ZIPSystem.com or contact Huber Engineered Woods for a retailer near you.

TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications are available through Huber Engineered Woods. Please visit ZIPSystem.com or call 800.933.9220 x2716 to speak to a technical representative.

AVAILABLE RESOURCES Section 06 16 00 SHEATHING for ZIP System Roof and Wall Sheathing products in CSI 3-part format is available at ZIPSystem.com or HuberArchitectLibrary.com.

WINDOW INSTALLATION DETAIL

ROUND PENETRATION DETAIL

MULTIPLE USES FOR ZIP SYSTEM STRETCH TAPE

© 2015 Huber Engineered Woods LLC. ZIP System® is a registered trademark of Huber Engineered Woods LLC. Huber is a registered trademark of J.M. Huber Corporation. HUB-9004 11/18

Create a window pan using

ZIP System stretch tape

Install ZIP System stretch

tape

ZIP System tape

(installed over all joints

between ZIP System

sheathing)

ZIP System tape or adhesive backed flashing (must meet

AAMA 711 or AC148) sealed over window flanges. jambs

and heads

Page 16: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof
Page 17: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

 

 

 

 ZIP SYSTEM® TAPE SUBMITTAL FORM  

Submitted to:                                                                                                                                                                                                        

 

Job Name: 

 

Submitted by: 

 

Date: 

 

Product:     3.75‐inch Linerless    6‐inch Linered       

 

     

Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 

800‐933‐9220. www.ZIPSystem.com . www.huberarchitectlibrary.com Technical Service Hotline: 800.933.9220 ext. 2716 

Page 18: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

ZIP SYSTEM® TAPE MANUFACTURER Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220 • Technical Service: 800.933.9220 x2716 ZIPSystem.com • HuberArchitectLibrary.com BASIC USE AND APPLICATIONS ZIP System Tape is a code-recognized flashing tape for use at sheathing panel joints, around windows, door frames, wall penetrations, and roof penetrations. Unlike most other flashing tapes, ZIP System Tape is compatible with flexible PVC windows. ZIP System Tape transforms ZIP System sheathing into a seamless protective barrier, providing superior air and moisture resistance to harsh elements. The combination of tape plus ZIP System Sheathing eliminates the need for a separate application of building wrap or roofing felt. Install the panels, tape the seams with ZIP System Tape, and the building is permanently weatherized. ZIP System Tape has four layered components:

• Heat and UV resistant acrylic adhesive that forms a lifetime bond with ZIP System Sheathing overlay

• Bonding layer that permanently joins the acrylic layer to the body of the tape

• Dimensionally stable inner layer of polyolefin that incorporates UV protection and antioxidants that make ZIP System Tape a lifetime product

• Slip resistant surface layer ADVANTAGES ZIP System Tape is a multi-purpose acrylic tape with a robust and aggressive adhesive. The intertwined polymer chains provide excellent internal strength and durability. The tape’s advanced acrylic adhesive is made of highly polar molecules; the resulting attraction pulls the tape into the ZIP System panel. This helps the tape wet out, and flow into panel ridges and produce a permanent bond. The installation satisfies the requirements of AC148 and AAMA 711-13 as represented in ESR-2227. The product’s specially formulated acrylic adhesion forms a superior bond making it a great versatile option to seal a variety of surfaces in all kinds of projects. ZIP System Tape also displays superior elongation, accommodating the normal expansion and contraction found in wood construction.

The use of ZIP System Tape as flashing material is recognized for use on Type V construction under the IBC and non-fire-resistance-rated construction under the IBC and IRC.

ZIP System Tape Maximum Exposure Time

180 Days

Adhesive Type Acrylic

Cold Temperature Application

0° F

Compatibility

Compatible with flexible PVC used in vinyl windows

Code Acceptance

IRC and IBC compliance recognized by ESR-2227

Tensile Strength 938 psi

Tape Elongation 400 – 800%

SIZE ZIP System Tape is available in 90 ft (27.4 m) long rolls in 3.75-inch (95.3 mm) and 6-inches (152 mm) roll widths. The 3.75-inch wide roll is produced with no release liner. The tape is also offered in individually package 6-inch (152 mm) by 75 ft (22.9 m) rolls with a split release liner in limited availability.

SUBSTRATE ZIP System Tape is not considered a substitute for self-adhering

ice and water barrier applications in roofing system; when such

materials are required, provide them in addition to application

of tape.

SUBSTRATE Ensure that the tape substrate is dry and free of frost, dust, dirt, loose fasteners, and other protrusions. Apply tape when ambient air and substrate are above 0 °F (-18 °C).

TAPE INSTALLATION Refer to manufacture’s ZIP System Roof and Wall Sheathing Installation Manual for detailed instructions and illustrations for application of ZIP System Tape to sheathing, flanged windows, brick mould windows and, penetrations openings. Apply tape as

Page 19: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof

prescribed in ICC-ES ESR-227, ESR-1473, ESR-1474, and ESR-3373. Tape should be covered with a code-complying roof or wall covering within 180 days of installation. ZIP System Tape is a pressure sensitive tape that must be rolled in (ZIP System Tape roller) to achieve maximum bond to the panel.

PANEL SEAMS Apply tape over sheathing joints in manner described in manufacturer’s written instruction, overlapping end joints a minimum of 3-inches (75 mm). Press tape firmly against substrate using a rubber-faced roller until smooth tape conforms tightly to the substrate.

WINDOWS AND PENETRATIONS Apply tape at sheathing penetrations as indicated in tape manufacturer’s written instructions. Apply tape at wall openings in manner described in window or door manufacturer’s written instructions. Details of installation recommendations are available in AutoCAD or PDF formats at ZIPSystem.com or HuberArchitectLibrary.com

STORAGE AND HANDLING Store ZIP System Tape in the original packaging at temperature not to exceed 90 °F (32 °C). Store in clean, dry place.

When stored as recommended in its original unopened container the typical shelf life for ZIP System Tape is 9 months from the date of manufacture.

WINDOW INSTALLATION DETAIL

AVAILABILITY Huber Engineered Wood’s ZIP System Tape is available through distributors nationwide. Visit ZIPSystem.com or contact Huber Engineered Woods for a retailer near you.

WARRANTY ZIP System Tape is furnished with a 30-year system warranty when used with ZIP System Sheathing. See ZIPSystem.com for details.

TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications is available through Huber Engineered Woods. Please visit ZIPSystem.com or call 800.933.9220 x2716 to speak to a technical representative.

AVAILABLE RESOURCES Section 06 16 00 SHEATHING for ZIP System Roof and Wall Sheathing products in CSI 3-part format is available at ZIPSystem.com or HuberArchitectLibrary.com.

DRYER VENT PENETRATION

© 2015 Huber Engineered Woods LLC. AdvanTech® is a registered

trademark of Huber Engineered Woods LLC. Huber is a registration

trademark of J.M. Huber Corporation. HUB-9002 11/18

Create a window pan using

ZIP System Tape or code-

recognized pan flashing

ZIP System Tape or adhesive backed flashing (must meet

AC148) sealed over window flanges at jambs

Install ZIP System Tape

or adhesive backed

flashing (must meet

AC148) in sequence

from bottom, sides,

then top to ensure

shingle lap of adhesive

backed flashing

ZIP System Tape

(installed over all joints

in ZIP System sheathing)

Use flanged vent hoods

Page 20: ZIP SYSTEM® SHEATHING SUBMITTAL FORM - Huber …€¦ · When Huber’s ZIP System sheathing is utilized for roof applications, felt underlayment is not required. In wall and roof