with sms / gsm / gprs communication - masermic...with sms / gsm / gprs communication bee en_c_160419...

6
www.masermic.com EN_C_160419 47 Datalogger With SMS / GSM / GPRS communication Bee

Upload: others

Post on 18-Apr-2020

27 views

Category:

Documents


0 download

TRANSCRIPT

www.masermic.com

EN_C_160419

47 Datalogger With SMS / GSM / GPRS communication

Bee

EN_C_160419

iLOGSBee devices are low consumption nodes with Digital / Analogical I/O and they can process and communica-

te data through a smart wireless network to a central iLOGS47 datalogger via ZigBee.

iLOGS47 is a data acquisition system and WSN central unit that logs, manages and comunicates the information

via GSM/SMS/GPRS.

COVERAGE OVER A WIDE AREA Using iLOGSBee nodes it is possible to cover a wide area distributing sen-sors over the network. The transmission-range is up to 350m (amplified) and up to 100m (without amplifier) and nodes can act as repeaters. It is possible to manage 50 nodes with each central iLOGS47 unit and tens of iLOGS47 in each PC. SMART MESH NETWORKS iLOGSBee nodes have a dynamic reaction when a change occurs in the mesh network: overcoming obstacles, finding a new route when single nodes fail and optimizing the power consumption. YEARS OF AUTONOMY iLOGSBee devices are designed in order to reach 2 years of autonomy with AA 3,6V (2,6A/h) batteries (depending on the configuration). The enclosure has a battery holder in order to change batteries easily and it is possible to power the device by its external power input (6V to 18V). iLOGS47 dataloggers can reach up to 6 years of autonomy with 7,2V (28A/h) batteries and it has a 12V input for external power supply. ANALOGICAL / DIGITAL INPUTS / OUTPUTS MODULES iLogsBee devices are supplied with 2 digital inputs (frequency meters or counters) or 2 analogical inputs + 1 digital output. LOGS47 has up to 8 digital inputs + 4 analogical inputs + 2 digital outputs. RUGGEDNESS AND MEMORY The solution can be installed outdoor thanks to the ruggedness of nodes (IP54) and the central unit (IP67). With regards to the memory, iLOGS47 can store 1Mb (35.000 registrations) and iLOGSBee can communicate data every 30 seconds (minimum). COST-EFFECTIVE SOLUTION The installation costs are reduced exponentially depending on the number of measuring points: cables, works, displacements, etc.

Tailored developments: iLOGSBee nodes can be used as base technology in order to create new products

adapted to specific applications. Consult us.

Wireless communications via ZigBee between nodes

and central unit (up to 350m range)

Data and alarms via GSM/SMS/GPRS to PCs or cell

phones

Multiple Digital/Analogical Inputs/Outputs locally or

in WSN.

Years of autonomy by batteries and 12V input

Ruggedness (IP54 and IP67 protected)

Monitoring Software compatible with other

SCADAs

Remote re-configuration and re-programming

E-mail and unlimited SMS.

Minimum installation and maintenance works

EN_C_160419

WIRELESS CONECTION AVOIDING WIRING TO THE DATALOGGER

Sensors and pulse transmitters are connected to iLOGSBEE nodes, from which information is communicat-

ed to a central iLOGS47 unit via ZigBee (max. 350m range). iLOGS47 communicates the information to a

remote server or cell phones via GSM/SMS/GPRS. This option is interesting if the wiring is difficult, expen-

sive or inaccessible.

WIRELESS SENSOR NETWORKS

iLOGSBee nodes can create Wireless Sensor Networks via ZigBee. The information flows through a self-

organized and smart mesh network to reach the iLOGS47 central unit. This option is interesting if it is need-

ed to cover a wide area installing many measuring points.

Operation and advantages

iLOGSBee in mesh networks of up

Applications

ENVIRONMENT

Crop control

Carbon emissions

Meteorological /

atmospheric control

Noise pollution control

Light pollution control

WATER

Water meters

Wastewater networks

Water supply networks

Pumping stations

Water wells

Water quality

ENERGY

Electrical values

Energy efficiency

Hidrocarbons

Wind energy

Gas storage

management

MULTISECTORIAL

Preservation

Automation

Containers

Cage control

Hazardous materials

Fleet management

iLOGS47 central unit

GSM/SMS/GPRS RF ZigBee SENSOR

SENSOR

EN_C_160419

Technical characteristics

47

PHYSICAL & ENVIRONMENTAL Box IP67 with front keypad (IP68 optional). Dimensions 180x130x50mm (changeable depending on the model).

Weight 500 grams (changeable depending on the model). Temperature -20ºC to +60ºC.

Humidity 95% (external condensation).

POWER SUPPLY Internal battery Internal lithium battery: up to 7,2V – 28Ah (6 years of autonomy - 5min/day GSM/GPRS). External power supply 12Vdc Input.

INPUTS/OUTPUTS Local Inputs 8 Digital dry contact Inputs / 4 Analogic Inputs 4-20mA or 0-10V (12 bits).

4 Counters V & Q flank sensitives. (Frequency 10 Hz).

Entradas remotas 8 Digital inputs (MODBUS RTU) / 30 Analogical inputs (MODBUS RTU). WSN Inputs Data reception from up to 50 iLOGSBee nodes via ZigBee. Outputs 2 bi-stable latch Digital Outputs. U/O Dry contact (max 2A).

1 24Vdc Output (50 mA max). WSN Outputs Digital outputs in iLOGSBee analogical nodes. Puerto COM RS232 & RS485 MODBUS RTU protocol (9600 bauds, 8 bits, 1 stop bit and NO parity). I/O Options - 4 Dig. Inputs + 2 Analog. Inputs / 1 24Vdc Output

- 4 Dig. Inputs + 2 Analog. Inputs / 2 Dig.Output + 1 24Vdc Output - 8 Dig. Inputs + 4 Analog. Inputs / 1 24Vdc Output - 8 Dig. Inputs + 4 Analog. Inputs / 2 Dig. Outputs + 1 24Vdc Output

COMMUNICATIONS GSM/GPRS Modem 850/900/1800/1900 MHz. GSM/GPRS Quad Band Modem GSM/GPRS Master The unit executes a call to dump the history log or send a GSM/GPRS/SMS alarm/message.

GSM/GPRS Slave GSM/GPRS reception for interrogation or remote synchronisation/reconfiguration. ZigBee transceiver Transceiver for the communication of information via ZigBee.

INTERNAL VARIABLES FUNCTION ¿MODIFIABLE?

Clock & date Task synchronization and time-tag. Yes, locally and remotely. Battery voltage Power supply remote supervision. Read only.

Temperature Internal temperature remote supervision. Read only. Connector presence Configuration connector detection. Read only - Alarm. Coverage level Remote supervision of GSM/GPRS coverage level. Read only.

Battery charge Shows remaining battery %. Read only.

PROGRAMMING TOOLS

Task pattern Executes group of functions, events, data sampling or output settings.

Calculations Maximum, minimum, average, accumulated value, module value, time input active, +, -, x, /.

Default events Serial connector plugged-in, memory overflow, low battery., configuration and firmware

update. User events Accepts the operators: =,>, <, <>, hysteresis operator, hysteresis complement, range and

Bolean values (true, false). Programming and association of iLOGSBee nodes.

HISTORY LOGS A configurable grouop of variables: Local, WSN or remote I/O, internal variables and calculation results.

A configurable group of alarm and events.

Configurable data sampling frequency (advise: max every 15 seconds). Configurable frequency between log-dumping (advise: min 5 minutes). All historical data is stored in 1Mb non-volatile memory (more than 35.000 records) upgradeable to 2Mb

REF:iLOGS47-D9x-X-X-YYY-YY

(D9x= Model)

(X= Battery options)

(X= Keypad options)

(YYY= I/O options)

(YY= Analogical inputs options)

ORDERING INFORMATION Model REF : D91 / D94 / D95

With internal battery / Without battery REF : X = A / X= B

With keypad / Without keypad REF : X = 1 / X=0

4 Dig. Inputs + 2 Analog. Inputs / 1 24Vdc Output REF : YYY = 420

4 Dig. Inputs + 2 Analog. Inputs / 2 Dig. Output + 1 24Vdc Output REF : YYY = 422

8 Dig. Inputs + 4 Analog. Inputs / 1 24Vdc Output REF : YYY = 840

8 Dig. Inputs + 4 Analog. Inputs/ 2 Dig. Outputs + 1 24Vdc Output REF : YYY = 842

Analogical Input 4-20 mA / 0-10V REF : YY = 20 / YY=10

EN_C_160419

Bee

PHYSICAL & ENVIRONMENTAL

Box 73x1166x24mm IP67 wall mount. Operation range -20ºC to +60ºC and 95% humidity (external condensation)

POWER SUPPLY

Internal power supply 2 x 3,6V / 2,6A/h AA lithium battery. Average autonomy: 2 years.

External power supply 6V to 18V

INPUTS/OUTPUTS

Digital node 2 Digital inputs (dry contact) Counters or flank sensitives. (Frequency 10Hz).

Analogical node 2 Analogical inputs 4-20mA (12 bits) + 1 Digital output

RF ZIGBEE COMMUNICATIONS

Mesh networks under “over the air” protocol. Based on IEE 802.15.4 standard, 2.4GHz band and 250Kbps bit rate. Encryption AES 128

Capacity Unattended networks of up to 500 nodes*. Transmission rate Programable (min 30 sec.)

INTERNAL VARIABLES

FUNCTION ¿MODIFIABLE?

Battery voltage Power supply remote supervision. Read only. Temperature Internal temperature remote supervision. Read only. Battery charge Shows remaining battery %. Read only.

REF:iLOGSBee-Dxx-X-XXX

(Dxx= Antenna options)

(X= Battery options)

(YYY= I/O options)

ORDERING INFORMATION Internal antenna (100m) / External antenna (350m) REF : D9 / D10

With internal battery / Without internal battery REF : X = A / X= B

Option 1: 2 Digital Inputs REF : XXX = 110

Option 2: 2 Analogical Inputs + 1 Digital Output REF : XXX = 110

Configuration and Monitoring

iDRIVER

iDRIVER is a specific driver software to make an interface with a SCADA software. It integrates the Binary GSM/GPRS communications protocol for data communication between the PC server and the dataloggers.

iSOFT

iSOFT is a software for the management and monitoring of iLOGS dataloggers and iLOGSBEE devices. This

software tool is installed in the PC server, and allows to receive via GSM/GPRS: alarms, the status of the data-

loggers, history logs, last received calls, the status of the batteries, etc.

iCONF47

iCONF47 is the configuration tool for iLOGS47 dataloggers and iLOGSBEE devices. It uses multiple and pow-

erful combinations of tasks, events, actions, calculations, etc. Hence, users can develop the specific function-

ing of their applications easily.

REF: iCONF47-XGE90

REF: iSOFT47-XGE91

REF: iDRIVER47-XGE92

[email protected]

Poligono Kurutz Gain 6A

20850 Mendaro - Gipuzkoa ( SPAIN )

Tel: +34 943 742669

www.masermic.com

EN_C_160419

The iLOGS product is a technological tool to support monitoring & control water & air parameters.

Due to the nature of the technologies used, the correct operation can be conditioned by others.

The Customer is informed and frees Microelectrónica Maser SL from any liability for damages arising

from the non-reception, delay, error or interception of communications, lack of reading this notice or

breach of specific obligations under the conditions set out therein.