Pilot Testing and Evaluation of Three Filtration Technologies for the Eugene / Springfield Wastewater Treatment Plant 2009 PNCWA Annual Conference Boise, ID September 15, 2009 By: Bill Bennett and Yan Seiner, P.E. Metropolitan Wastewater Management Commission Onder Caliskaner, Ph.D., P.E, Steve Celeste, P.E., and Kevin Farthing, P.E. Kennedy/Jenks Consultants

Upload: others

Post on 15-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Testing and Evaluation of Three Filtration Technologies for the Eugene / Springfield Wastewater Treatment Plant

2009 PNCWA Annual Conference

Boise, ID

September 15, 2009

By:

Bill Bennett and Yan Seiner, P.E.

Metropolitan Wastewater Management Commission

Onder Caliskaner, Ph.D., P.E, Steve Celeste, P.E., and Kevin Farthing, P.E. Kennedy/Jenks Consultants

I will present you a new depth filtration model which was developed for the filtration of secondary effluent using an innovative filtration technology.
Page 2: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Presentation Overview

§ Project Overview§ Operational Perspective§ Pilot testing systems§ Pilot testing results § Questions

Page 3: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

About MWMC

• Formed as a partnership between Eugene, Springfield, and Lane County. Established in 1978 to serve as recipient for EPA funding of new treatment facilities.

• City of Eugene operates and maintains treatment plant, biosolids facility and lift stations. biosolids facility and lift stations.

• City of Springfield provides administrative support of the regional wastewater program including management of the Capital Improvements Program.

Page 4: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Current ADWF = 25 mgdDesign ADWF = 49 mgdDesign AWWF = 75 mgd

Treatment Processes:

Eugene/Springfield WPCF

Treatment Processes:§ Screening/Grit Removal§ Primary Sedimentation§ Selector Activated Sludge§ Secondary Clarification§ Chlorine Disinfection§ Dechlorination§ Willamette River Discharge

Page 5: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

MWMC Facilities Plan

Cost-effective solution for regional for wastewater needs through 2025.

Established in a joint effort between MWMC and CH2M Hill.

Adopted in 2004

Tertiary filtration one of ten major capital improvement projects.

Page 6: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Tertiary Filter Project

From MWMC Facilities Plan:

§Phase 1: 11 mgd filtration capacity

§Year 2025: 33 mgd filtration capacity§Year 2025: 33 mgd filtration capacity

§Comply with effluent TSS limits

§Produce Class A recycled water

§Placeholder for future design

Page 7: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Project Team

Operation and Maintenance, City of Eugene•Bill Bennett, Filtration Pilot System O&M Lead

•Steve Barnhardt

Engineering•Yan Seiner, City of Springfield, MWMC Project Manager

•Onder Caliskaner, Kennedy Jenks, Tertiary Filtration / Pilot Testing Process Lead•Steve Barnhardt

•Rick Clark

•Kim Olsen

•Dennis Gabrielson

•Matt Hays

•Chris Jeffress

•Tim Bridgeford

Testing Process Lead

•Kevin Farthing, Kennedy Jenks, Pilot Testing Staff Engineer

•Steve Celeste, Kennedy Jenks, Tertiary Filtration Project Manager

Page 8: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Project overviewApproach

Step 1. Filtration technology alternatives evaluation/selection

Outcome: Select three technologies for pilot testing

Step 2. Manufacturer selection for pilot testing: request for information process

Outcome: Select one manufacturer for each selected technologytechnology

Step 3. Conduct pilot testing

Outcome: Evaluate technology alternatives

Step 4. Preliminary design

Outcome: Select technology upon which to base design

Step 5. Design

Step 6. Bidding

Step 7. Construction

Page 9: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Project objectives

Comply with permit requirements

Comply with Class A recycled water requirements

Minimize energy demands

Minimize chemical use

Minimize impacts to other processes

Flexible operations

Maintainable

Expandable

Minimize footprint

Page 10: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Project Overview Simplified flow diagram for Effluent TSS Removal

Page 11: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Project Overview Simplified flow diagram for Class A Recycled Water

Page 12: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Tertiary Pilot Filter TestingAn Operational Perspective

Eugene, Oregon

July – November 2008

Page 13: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing: ExpectationsMeet early on with consulting engineers:

§ Determine types and number of filters to be tested.

§ The number of test filters offered by vendors is limited and scheduling needs to be done well in advance of the project.

§ Contracts will need to be negotiated with the vendors. Test filters are not free. are not free.

Have a goal of what information you want to get from the tests.

• Solids Removal.

• Ease of operation.

• Maintenance time, repair costs.

• Responsiveness of the vendors.

Page 14: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Filter Site

Close to source of water to be treated.

Large enough to accommodate filters to be tested.

Page 15: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Water Source

Process stream used for the pilot test should be the same as what will be used for the permanent installation.

Page 16: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Power Supply

A power supply sufficient for all filters, pumps, and ancillary equipment will be needed.

Filter manufacturers will be able to supply data for their units.

Page 17: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Daily ChecksFILTER #1: DAILY CHECK SHEET

Date:____________________ Time:__________________ Test Number_____________ Op’s Initials:____________

Local Panels Turbidimeter Particle Counter

Check for power and data

displays

Clean lens

Clean lamp and glass under lamp

Drain and clean sample collection cell

If reading zero, check for burned out bulb.

Flush tubing as required

Clean strainers and tubing

Sample Collection

Determine Frequency

Be Consistent with checks,

Comments:

Sample Collection TSS Turbidity (Hand Meter)

Influent Grab mg/l *

Influent Composite

mg/l 1

Effluent Grab mg/l

Effluent Composite

mg/l2 Effluent NTU

Secondary Effluent Channel NTU

N/A

Data Readouts Influent Flow gpm

Headloss (Goal <2” change)

Pump Pressure

(Goal 40 psi)

Air Pressure (Goal 5 psi)

Effluent NTU Effluent Particle Size

Sample Flow Rates (Timed measurement with graduated cylinder)

Filter Flow

Effluent Turbiditmeter (Goal 400-600ml/min)

Effluent Particle Size (Goal 100 ml/min)

(If filter is not up to setpoint, shut unit down and clean inlet strainer.)

corrections, and adjustments.

Coordinate sampling with equipment checks.

Document findings.

Page 18: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: On Line Solids Meters

§ Turbidity Meters• Require routine cleaning.• Flow rate adjustments

need to be made based on vendor/consultant guide-lines. lines.

§ Particle Counters• Problematic with frequent

plugging. • Flow rates were

recommended, but

difficult to maintain.

Page 19: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: SamplingComposite Samples

• Allow for 24 hour sampling. • 15-30 minute intervals

recommended. • Lab results can be compared to

electronic data.

Grab Samples§ Grab Samples• Taken at time of equipment

check.• Results can be compared to

on-line meters at time of sample.

• Designate specific sample points.

§ All Samples can be stored and tested later.

Page 20: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Samples

§ Sample Containers• One-liter bottles for grab

samples. • Ten-liter bottles for

composites. • Pre-labeled • Pre-labeled

§ Green Transportation for delivery to lab.

Page 21: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Lab Tests

§ Turbidity Meter• Additional data to augment

online meters. • Use for composite and

grab samples. • Hint: Pour sample into

vials and allow to reach room temperature before room temperature before running samples. Cold sample will fog the glass.

§ Suspended Solids• Standard test as used for

plant effluent. • Volume for lab tests may

need to be adjusted when doing PE or upset testing.

Page 22: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Primary Effluent Testing§ PE/Secondary Effluent

• PE diluted to ~50 mg/l to simulate high flow conditions.

• Possible use of filters is to reduce effluent suspended solids to meet 85% removal and mass load requirements.

§ Dilution§ Dilution• PE and SE mixed in injection

chamber of off-line chlorine contact chamber.

• 4” Chlorine line used to move PE from aeration basins to filters.

• Suspended solids probe used to measure solids level and make dilution at the contact chamber.

Page 23: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Plant Upset Testing

§ Mixed Liquor/Secondary Effluent • ML diluted to ~25 mg/l to simulate upset

of secondary treatment process. • Possible use of filters is to reduce

effluent suspended solids during a plant upset to meet permit limits.

§ Dilution• ML and SE mixed in injection chamber

of off-line chlorine contact chamber. • 4” Chlorine line used to move ML from

channel by secondary clarifiers to filters.

§ Suspended solids probe used to adjust flows to reach target.

• Dilution not an exact science.

Page 24: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test: Experience Gained

§ Plan Ahead• Samplers or other

equipment may have a long delivery time.

§ Know Your Limitations• Staffing requirements may

be greater than anticipated. be greater than anticipated. – A student or intern to check the

filters and/or run lab samples would be an option.

§ Separate filters from ancillary equipment• Problems with online meters

or other equipment may not be indicative of filter performance.

Page 25: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Study Results - Outline

§ Objectives of pilot filter studies

§ Pilot testing program and scope

§ Pilot test program data / results

§ Summary of performance results

Page 26: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing ProgramObjectives

Principal objective:

§ Evaluate performance of filters with specific consideration of the recycled criteria and NPDES requirements

Specific Objectives of the Pilot Testing Program:Specific Objectives of the Pilot Testing Program:

§ Determine/Confirm design criteria

§ Evaluation of the filters’ reliability, operational and maintenance requirements

§ Determination of the backwash requirements

Page 27: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing ProgramScope

Testing of the following three filter technologies:

§ Granular – Continuous Backwash Up-flow (Blue Water Technologies)

§ Compressible Medium Filter (Schreiber)

§ Disk Filter (Aqua Aerobics Systems)

at the following three filtration rates:

§ Average filtration rate

§ Design filtration rate

§ Peak design filtration rate

for the following conditions:

§ Secondary effluent filtration without chemical addition

§ Secondary effluent filtration with chemical addition

§ Primary effluent filtration and upset simulation testing

Page 28: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Test Program

Net testing : 20 weeks

§ Total of 31 tests for each pilot filter system

§ Each test is between 2 and 7 days

§ 25 tests for secondary effluent filtration without chemical addition : about 14 weeksaddition : about 14 weeks

§ Two tests for chemical addition : approximately three weeks

§ One test for simulation of upstream upsets: approximately one week

§ Three tests for primary effluent filtration: Approximately 10 days

Page 29: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Units

Aqua Aerobic Systems cloth disk filter

Schreiber Schreiber compressible media filter

Blue Water Technologies granular media filter

Page 30: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Cloth Disk Filter

Page 31: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Upflow Continuous Backwash Granular Filter

Page 32: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Compressible Medium Filter

Page 33: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filters – Design Criteria

Filtration Surface Area,ft2

Hydraulic Loading Rate, gpm/ft2

Medium Properties

Average Design Increased Design

Medium Depth, inches

EffectiveSize

Porosity%

Compresratio %

MediaType

Continuous 12 3.5 5 6-6.5 60 0.95 40 N/A SandContinuous Backwash Granular Filter

12 3.5 5 6-6.5 60 0.95 mm

40 N/A Sand

Compressible Medium Filter

2.25 20 30 35-40 30 0.17(a) 85 5-40 Synthetic

Cloth Disk Filter

12 3.25 6 7 0.2 10 µµµµM N/A Pile Cloth

Page 34: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Evaluation of Filtration Technologies Performance Criteria

Turbidity / TSS removal

Headloss development

Backwash reject ratioBackwash reject ratio

Chemical aid requirements

Particle size distribution modification

Page 35: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Turbidity and TSS Requirements/Objectives

Parameter Objective

Daily Average < 2

Turbidity (NTU)

Daily Average < 2

Not to exceed more than 5% of the time 5

Cannot exceed at all times 10

TSS (mg/l) Monthly Average < ~ 4 - 5

Daily Maximum < ~ 10 - 15

Page 36: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

MWMC Compressible Medium Filter Turbidity Removal Performance

Influent and effluent turbidity values for CMF between 07-14-2008 and 07-21-2008

6.00

7.00

8.00

0.00

1.00

2.00

3.00

4.00

5.00

0 1000 2000 3000 4000 5000 6000 7000Time, min

Turbidity,

NTU

Page 37: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing Program Summary of Average Effluent Turbidity Results

Average Influent and Effluent Turbidity Values (without chemical addition)

3.5

4

4.5

5

Cloth Disk Filter Granular Filter Compressible Medium Filter Influent Turbidity

0

0.5

1

1.5

2

2.5

3

3.5

0 5 10 15 20 25

Test No

Turbidity, NTU

Page 38: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing Program Summary of Average Effluent Turbidity Results

Secondary Effluent Filtration (no chemical addition)

3.50

4.00

4.50

5.00

0.00

0.50

1.00

1.50

2.00

2.50

3.00

0% 20% 40% 60% 80% 100%

Fraction under

NTU

Influent

Cloth Disk

Granular Media

Comressible Media

Page 39: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing Program - Summary of Average Influent and Effluent Turbidity Results

Average Influent and Effluent Turbidity Values (no chemical)

2.99

2.62

3.052.85

2.50

3.00

3.50

Influent Cloth Disk Filter Granular Filter Compressible Medium Filter

1.44 1.461.651.711.62

1.721.61

1.27

1.57

1.02

1.45

1.31

0.00

0.50

1.00

1.50

2.00

2.50

Overall Average Average filtrationrate

Design filtration rate Increased designfiltration rate

Turbidity, NTU

Page 40: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Turbidity ResultsSecondary Effluent Filtration without Chemical addition

Class A recycled water turbidity requirements are expected to be achieved with all three filtration technologies tested for average secondary effluent turbidities up to approximately 5 NTU without chemical addition

The turbidity removal performance of the three filters was observed to The turbidity removal performance of the three filters was observed to be similar. Average turbidity removal efficiency was approximately 50 to 55 percent for all three filters

Average observed effluent turbidity values were less than 1.8 to 2.0 NTU for all three filtration technologies for the majority of the tests

Page 41: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing Program Average TSS (composite samples) Results for Individual Test

Average Influent and Effluent (Composite) TSS Values(without chemicals addition)

14

16

18

Cloth Disk Filter Granular Filter Compressible Medium Filter Influent TSS

0

2

4

6

8

10

12

0 5 10 15 20 25 30

Test Number

TSS (m

g/L)

Page 42: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Pilot Filter Testing Program Overall Average TSS (composite samples) Results

Average Influent and Effluent Composite TSS Values

11.22

8

10

12

TSS, m

g/l

3.453.51

2.87

0

2

4

6

Influent Cloth Disk Filter Granular Filter CompressibleMedium Filter

TSS, m

g/l

Page 43: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of TSS ResultsSecondary Effluent Filtration without Chemical addition

Future discharge TSS concentration requirements are expected to be achieved with all three filtration technologies for secondary effluent TSS values up to approximately 25 mg/L without chemical addition.

The average effluent TSS was less than 5 mg/L for all three filters for the majority of the tests during normal plant operating conditions.the majority of the tests during normal plant operating conditions.

The TSS removal performance of the three filters was observed to be similar. The removal performance of CDF appears to be approximately 15-20 percent higher compared to CMF and GCBF.

Without chemical addition, average TSS removal efficiency was between 60 and 70 percent.

Page 44: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Backwash Water Ratio Results

Average Backwash Water Ratio for Secondary Effluent Filtration Tests without Chemical Addition

25.0%

30.0%

Backw

ash water ratio, %

CDF UGCBF CMF

For 10 mgd average plant flow:

% 2 Backwash Reject Ratio means 0.2 MGD returned to headworks : average plant flow increases to 10.2 mgd

0.0%

5.0%

10.0%

15.0%

20.0%

0 5 10 15 20 25

Test No

Backw

ash water ratio, %

% 15 Backwash Reject Ratio means 1.5 MGD returned to headworks : average plant flow increases to 11.5 mgd

Page 45: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Backwash ResultsSecondary Effluent Filtration without Chemical addition

Backwash water ratio was observed to be between 1 percent and 5 percent for CMF and CDF for most tests. Average BWR was around 3 – 4 percent.

Backwash water ratio for GCBF was observed to be significantly higher compared to CMF and CDF. Average BWR was approximately 25 percent.percent.

For actual installation with similar loading conditions, backwash water ratio is expected to be between 1 percent and 2 percent for CMF and CDF.

For actual installation with similar loading conditions, backwash water ratio is expected to be between 10 percent and 15 percent for GCBF.

Page 46: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Headloss development for Cloth Disk Filter 07-10-2008 (filtration rate 3.2 gpm/ft2 - 6.0 gpm/ft2)

4.75

4.95

5.15

MWMC Cloth Disk Filter Headloss Development

3.75

3.95

4.15

4.35

4.55

4.75

850 950 1050 1150 1250 1350

Run time

Pressure, ft

Page 47: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Headloss development versus time for CMF between 09-08-2008 and 09-15-2008

5.0

6.0

7.0

Headloss,

headloss, ft

MWMC Compressible Medium Filter Headloss Development

1.0

2.0

3.0

4.0

0 1000 2000 3000 4000 5000 6000 7000 8000 9000Time, min

Headloss,

ft

Page 48: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Headloss ResultsSecondary Effluent Filtration without Chemical addition

Headloss development (through the medium) varies significantly between the three filtration technologies:

§ CDF: Headloss development ranged between 0.4 feet and 0.9 feet with an average value of approximately 0.7 feet.an average value of approximately 0.7 feet.

§ CMF: Headloss development ranged between 0.6 feet and 4.2 feet with an average value of approximately 1.6 feet.

§ GCBF: Headloss development ranged between 1.2 feet and 4.3 feet with an average value of approximately 2.3 feet.

Page 49: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Secondary Effluent Filtration with Chemical Addition Cloth Disk Filter

Influent and effluent turbidity values for CDF with chemical addition 9-22-2008

6

7

8

InfluentTurbidity Effluent Turbidity

Successful chemical addition

No chemical addition Unsuccessful chemical addition

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000Time, (every 30 seconds)

Turbidity,

NTU

Page 50: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Chemical addition testsCloth Disk Filter - Impacts on headloss development

Headloss development for Cloth Disk Filter 09-22-2008 (chemical addition)

5.25

5.35

4.75

4.85

4.95

5.05

5.15

850 950 1050 1150 1250 1350

Run time

Headlos

s, ft

Page 51: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Chemical Addition Results

Turbidity removal efficiency increased to 70-75 percent with chemical addition for all three filters.

TSS removal efficiency increased to 80-85 percent with chemical addition for all three filters.

With chemical addition, compliance with Class A recycled water requirements is expected for secondary effluent turbidity values up to approximately 8 NTU.

With chemical addition, compliance with effluent TSS concentration requirements of 10 mg/L is expected for secondary effluent TSS values up to approximately 40 mg/L.

Page 52: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of Chemical Addition Results

Filtration removal efficiency increases with successful chemical addition, but it was observed to decline typically after 1 to 3 hours of chemical addition.

Backwash Water Ratio increased significantly for CMF and CDF (e.g., 5 to 10 times) as a result of chemical addition.

Medium blinding was observed to be a typical operational problem with chemical addition.

Chemical addition should be exercised only to meet recycled water requirements when necessary for a short period (e.g., one hour) during one filtration cycle.

Page 53: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Evaluation of Filtration PerformanceParticle Size Distribution Modification

Especially important to ensure required disinfection efficiency

The removal of particles between ~ 5 and 15 to 20 micron in size is crucial to increase disinfection efficiency

Page 54: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Upflow Granular Continuous Backwash FilterEffect of Chemical Addition on Particle Size Distribution

Effluent particle size distribution versus time for CBGF (with chemical addition 50-10-20 ppm)

50000

60000

70000

80000

Particle Count

Chemical dose increasedChemical addition started

0

10000

20000

30000

40000

50000

9/13/0812:00 AM

9/13/0812:00 PM

9/14/0812:00 AM

9/14/0812:00 PM

9/15/0812:00 AM

9/15/0812:00 PM

9/16/0812:00 AM

9/16/0812:00 PM

9/17/0812:00 AM

Time

Particle Count

2-5 Micron, Count 6-10 Micron, Count 11 - 20 Micron, Count 21 > Micron, Count

Chemical dose decreased

Page 55: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

QUESTIONS & COMMENTS

Bill Bennett

[email protected]

(541) 682 - 8618

Onder Caliskaner

[email protected]

(916) 858 - 2738

Page 56: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Upset Simulation Turbidity Results for CDF

Influent and effluent turbidity values for CDF upset testing with MLSS

80.00

100.00

InfluentTurbidity Effluent Turbidity

0.00

20.00

40.00

60.00

80.00

0 2000 4000 6000 8000Time, min

Turbidity,

NTU

Page 57: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Upset Simulation Turbidity Results for CMF

Influent and effluent turbidity values for CMF upset testing (spiked with MLSS)

80.0090.00100.00

InfluentTurbidity Effluent Turbidity

0.0010.0020.0030.0040.0050.0060.0070.00

0 1000 2000 3000 4000 5000Time, min

Turbidity,

NTU

Page 58: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Upset Simulation Turbidity Results for UGCBF

Effluent turbidity versus time for BWT upset testing (spiked with MLSS)

80

100

EffluentTurbidity Influent Turbidity

0

20

40

60

80

39736 39737 39738 39739 39740 39741 39742 39743Time, min

Turbidity,

NTU

Page 59: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Primary Effluent Filtration TSS Results

Primary Effluent FiltrationInfluent and Effluent TSS Values

32.50 30.8

38.4

30.00

35.00

40.00

45.00

TSS, m

g/l

9.60 10.30

20.8

161613.2

18.4

8.80

12.8

0.00

5.00

10.00

15.00

20.00

25.00

Test 1 Test 2 Test 3

TSS, m

g/l

Influent Cloth Disk Filter

Granular Filter Comressible Medium Filter

Page 60: Wastewater Filtration Operation PNCWA- Session 11-3 - Water Reuse - Steve...Turbidity Meter • Additional data to augment ... The turbidity removal performance of the three filters

Summary of ResultsPrimary Effluent Filtration Tests

For primary effluent filtration, the filters’ removal performances were comparable.

TSS removal efficiencies were observed to range between 40 percent and 75 percent for the three filtration technologies. The removal performance of CMF appears to be approximately 10 percent higher compared to CDF and GCBF.

For primary effluent filtration, the BWR ratios were observed to be between 15 and 20 percent for CDF and CMF. The BWR ratio was approximately 25 percent for GCBF.