vibxpert brochure lud

6
VIBXPERT ® 2-Channel Vibration Analyzer 102,400 lines of resolution Weighs only 2.2 lbs. Simple joystick operation Signal post processing Bearing databases Machine fault frequency markers Graph-based route

Upload: others

Post on 27-Oct-2021

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VIBXPERT brochure LUD

VIBXPERT® 2-Channel Vibration Analyzer

• 102,400 lines of resolution

• Weighs only 2.2 lbs.

• Simple joystick operation

• Signal post processing

• Bearing databases

• Machine fault frequency markers

• Graph-based route

Page 2: VIBXPERT brochure LUD

VIBXPERT® is versatile• Overall values include

machine vibration,shock pulse,temperature, RPM

• Process parameters

• Visual inspection data(only in Route mode!)

• Diagnosis

• Signal processing

• Roller bearing database

• Balancing 1 or 2 plane(optional)

• Built-inISO standards

The VIBXPERT® vibration data col-lector and signal analyzercombines route-based data collec-tion with machine diagnostics inone tool.

VIBXPERT® excels in

• Fast data acquisition

• Complete data analysis on-site

• Useful knowledge-based setups– Intuitive for beginners– Powerful for experts

• Connections support almost allsensor types (e.g., triax sensors)

Powerful, yet intuitive

VIBCODE®

Automatic measurement loca-tion identification byVIBCODE® ’fingerprint’ – thecoded ring!• No mix up of measurement

locations• Reproducible measure-

ments• Stable connection• Defined contact pressure• Defined measurement di-

rection

Simultaneous!Carries out two measurementsat the same time – with orwithout trigger/RPM as re-quired.• Dual channel measure-

ments for diagnosis andcorrection- orbit- cross phase- coast down- 2-plane balancing

• Independently selectabledual channel measurementtasks.

Portable!Lightweight design with carry-ing strap, ideal for machinerysurvey.

The best connections!5 robust color-coded connec-tors on the upper side of thedevice are stable, cannot beconfused and are dustproof.

Meas. channels /Charging jack

Temperature

Trigger / RPMSerial - RS 232

Signal OutUSB / Ethernet

Protective dust caps

IP65 rated

Page 3: VIBXPERT brochure LUD

Clear displayThe high-contrast backlit dis-play (1/2 VGA) is easy to read –even in broad daylight.

VIBXPERT® at a glance

Single-handed operationInstinctive joystick operationwith ergonomically arrangedkeys.

VIBXPERT® with its comprehensivemeasurement and analysis func-tions and intuitive user operation isideal for routes.Together with the OMNITREND®

PC software, VIBXPERT® providesan important contribution to con-dition-based maintenance forpreventing unforeseen machinebreakdowns and expensive pro-duction losses.

VIBXPERT® lights upIf it‘s too dark, VIBXPERT® au-tomatically switches on thekeyboard illumination. Thelighted display allows work dayor night.

Expandable memoryReplaceable flash card pro-vides virtually unlimitedmemory (standard 2 GB).

Alarm displayto ISO standardsFour indicator LEDs onthe display indicate'Everything OK' (blue)‘Prewarning' (green)'Warning' (yellow)'Alarm' (red).

Page 4: VIBXPERT brochure LUD

The attractive external design ofVIBXPERT® is also reflected in itsinternal structure: intuitive, graphi-cal user interface, straightforwarduser guidance and a constantlyavailable help function allow notonly skilled experts, but also aninexperienced novice to quicklyachieve reliable results.

Route options

Intuitive operation

VIBXPERT® really measures up!

File Manager with‘Windows’ design

Icon driven menu Measurement task selection

Route composition in OMNITREND®

FunctionalityWindows-style File Managerfor non-route data storage.Easily transferred to OMNI-TREND® PC software. Iconguided navigation with easytask selection.

See, click - measure!Visual route guidance usingmachine graphics provides ahigh degree of convenience forthe user. VIBCODE® recognizesthe measurement position au-tomatically.

Measurement location selection in thetrees view...

... or using the machine graphic

Page 5: VIBXPERT brochure LUD

Evaluation

Signal Analysis

OMNITREND®

PC software

Measurement values and alarm violation Trend graph with alarm limits Identification of damage frequencies

Barely increased measurement values at 50 Hz(electrical failure)

High vibration level at 122 Hz(= 1st impeller passing frequency)

Coast down measurement indicatesthe resonance points

Shaft displacement as orbit

Condition monitoringRegular recording of measure-ment values provides a clearpicture of the machine condi-tion trend.

The 2-channel VIBXPERT®

comes equipped with phasemeasurement, coast downmeasurement, orbit, cepstrum.

Optional Expert Diagnostics fea-tures can be added at any time:• Extended Time Waveform

collection• Transient data collection• Modal/ODS capability• Data export via Universal File

Export (UFF).

OMNITREND® manages machinedata, programs measurement tasksand routes, and archives the resultsin a database (MS Access, Oracle*,MS SQL*). Comprehensive func-tions are available for evaluationand documentation: alarm check,trend preview, multiview, bandanalysis, waterfall display, fre-quency markers and variouscursors.

Alarms & diagnosisIf there is an alarm, narrowband monitoring in the fre-quency spectrum shows thedamaged component. Fre-quency markers supportidentification of characteristicfrequencies typical for specifictypes of damage. Additionalfunctions for diagnosis can becalled up via a menu.

*optional

Recording the vibration amplitudesin a narrow frequency band

Cross-channel phase measurement

VIBXPERT® grows with your needs!

Page 6: VIBXPERT brochure LUD

Measurement channels

2 analog channels (A & B), selectable:- Voltage (AC/DC, ±30 V max.)- Current (AC/DC, ±30 mA max.)- ICP® signal (2 mA, 24 V max.)- LineDrive signal (10 V, 10 mA max.)

1 analog channel:- temperature probe (thermocouple type K)

1 digital channel:- 1+1 pulse/tacho (RPM, trigger, key phaser)- Pulse & AC signals (± 26 V)

Parameters - analog measurement channels (A & B)

Frequency range 0.5 Hz to 51 kHz

Dynamic (measured/total) 96 dB / 136 dB

Sampling rate <131 kHz per channel

Outputs

Stroboscope control: TTL

Signal out: for headphone and signal processing

Measurement range / AccuracyRPM 10...200 000 rpm / ±1‰ / ±1rpm

Temperature -50...+1000°C / ±1% / ±1°C

VIBXPERT® technical dataDisplacement* 6000 µm (p-p) / ±5%

Velocity* 6000 mm/s (p-p) / ±1%

Acceleration* 6000 m/s² (p-p) / ±1%

FFT

Fmin 0.5 Hz ... 10 Hz, selectable

Fmax 200 Hz ... 51 kHz, selectable

Lines 400 ... 102,400

Window Rectangular, Hanning, Hamming,Blackman, Bartlett, Flattop, Kaiser

Operating modes

Multimode (non-route)- Overall values: vibration (acceleration, velocity,displacement), current, voltage (AC / DC), shockpulse (roller bearing condition), temperature, RPM- Signals: spectrum (amplitude, envelope), timewaveform, cepstrum, phase & cross-channelphase, orbit, coast down, impact test

Data acquisition (Route)- Guidance via tree, list view or machine graphic- Process optimization for quick data acquisition

Balancing (optional)- Dynamic balancing in 1 or 2 planes

Memory

RAM, internal 256 MB

CompactFlash 2 GB, upgradeable

Display

LCD, illuminated, 480 x 320 pixels (1/2 VGA)

Supply

Lithium-Ion battery, exchangeable (7.2V / 4.8Ah).

Chargeable in device. charge time < 5 hours

Temperature range

Storage -4°F...+140°F

Operation 14°F...+140°F

Protection class

IP65, dustproof and waterproof

Dimensions

7.1 x 6.3 x 2 inches (LxWxH)

Weight

2.6 lbs.

Further technical data is given in the VIBXPERT® ProductCatalog, available for download as a PDF on our website.

* Current LineDrive transducer (1µA/ms-²) and sensorwith voltage output (100mV/g); Reference: 159.15 Hz

LUDECA Inc.1425 N.W. 88th AvenueDoral, FL 33172www.ludeca.comPhone: (305) 591-8935Fax: (305) 591-1537eMail: [email protected]

PRÜFTECHNIKCondition Monitoring85737 Ismaning, Germanywww.pruftechnik.comPhone: +49 89 99616-0Fax: +49 89 99616-300eMail: [email protected]

Balancing (optional)

The VIBXPERT® case is robust with itscustomized foam inlays, guaranteesoptimum transport protection forthe components and numerous ac-cessories. Compact dimensions andthe low overall weight makes it ahandy companion.

Graphically assisted program for in-tuitive operation. Trial weightestimator suggests appropriateweight and placement. Single ordual vector display with a runninghistory of the job. Built-in ISO toler-ances.

Balancing in one or two planes ‘Smiley’ appears when ISO BalancingGrade Tolerances are met

© Copyright 2005 by PRÜFTECHNIK AG. VIBXPERT® and VIBCODE® are registered trademarksof PRÜFTECHNIK Dieter Busch AG. No copying or reproduction of this information, in any formwhatsoever, may be undertaken without express written permission of PRÜFTECHNIK AG. Theinformation contained in this leaflet is subject to change without further notice due to thePRÜFTECHNIK policy of continuous product development. PRÜFTECHNIK products are thesubject of patents granted or pending throughout the world. VIB 9.800.12.10.LUD