user’s guide - sprinkler talk · irrigation system controller user’s guide • setup •...

120
Irrigation System Controller User’s Guide • Setup • Installation • Programming • Troubleshooting v Indoor and Outdoor 6-, 9-, and 12-station Models v English Español Français

Upload: phungnhu

Post on 04-Jun-2018

250 views

Category:

Documents


0 download

TRANSCRIPT

  • Irrigation System Controller

    Users Guide Setup Installation Programming Troubleshooting

    v Indoor and Outdoor 6-, 9-, and 12-station Models v

    English

    Espaol

    Franais

  • Getting to Know Your Rain Dial Controller . . . . . . . . . . . . . .23

    Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

    BatteryInstallationandArmchairProgramming . . . . . . . . . . 4-5

    Overview:ControlModuleInterface . . . . . . . . . . . . . . . . . . . . 6-7

    Overview:InternalControllerComponents . . . . . . . . . . . . . . 8-9

    Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1015

    InstallingtheControllerCabinet . . . . . . . . . . . . . . . . . . . . . . . .10

    ConnectingtheValveControlWiring . . . . . . . . . . . . . . . . .1011

    ConnectingaRainSensor(optional) . . . . . . . . . . . . . . . . . . . .12

    ConnectingaRemoteControlUnit(optional) . . . . . . . . . . . . .13

    ConnectingtheEarthGroundDevice . . . . . . . . . . . . . . . . . . .14

    ConnectingthePowerSource . . . . . . . . . . . . . . . . . . . . . .1517

    IndoorModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

    OutdoorModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1617

    ControllerStationTestFeature . . . . . . . . . . . . . . . . . . . . . . . .17

    Getting the Most From Your Rain Dial Controller . . . . . . .1819

    SampleWateringPlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

    What the Display Indicates . . . . . . . . . . . . . . . . . . . . . . . . . .2021

    Basic Programming Procedures . . . . . . . . . . . . . . . . . . . . .2225

    SettingtheCurrentTimeandDay . . . . . . . . . . . . . . . . . . . . . .22

    SettingtheValveRunTimeDuration . . . . . . . . . . . . . . . . . . .22

    SettingtheProgramCycleStartTime(s) . . . . . . . . . . . . . . . . .23

    SettingtheProgramWateringDaySchedule . . . . . . .2325

    ToSetaWeekdaySchedule: . . . . . . . . . . . . . . . . . . . . . .23

    ToSetaSkipDaySchedule: . . . . . . . . . . . . . . . . . . . . . . .24

    ToSetanOdd/EvenDateSchedule . . . . . . . . . . . . . .2425

    DayExclusionFeature . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

    ii

    F Table of Contents

  • Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2629

    RainDelay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

    WaterBudget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2628

    ToApplyaBasicWaterBudget: . . . . . . . . . . . . . . . . . . . .27

    ToApplyaMonthlyWaterBudget: . . . . . . . . . . . . . . .2728

    Stack/Overlap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

    StationDelay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

    PumpControlDuringStationDelay . . . . . . . . . . . . . . . . . . . .30

    PumpControlOption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

    Diagnostic Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

    Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

    Manual Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3233

    Semi-automaticProgramOperation . . . . . . . . . . . . . . . . . . . .32

    ManualStationOperation . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

    Clear Program Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

    Restore Rain Dial-R to Factory Default Settings . . . . . . . . . .35

    Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

    Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

    Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

    FCC Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

    1

  • F Getting to Know your Rain Dial Controller

    To take full advantage of your new Rain Dial-R controller, take a few moments to become familiar with its many features:

    Modular design Provideseasyaccesstovalveconnectionter-minalsandbatterystorage .Snap-outdesignenablesthecontrolmoduletobeeasilyremovedforArmchairProgramming .

    Remote control ready Built-inRJ-11jackfordirectconnectiontoIrritrolCMR-KITorKSR-KIThandheldremotecontrolsystems .

    Non-volatile memory Keepsalluser-definedwateringprogramsstoredinmemoryforseveralyearswithout power!

    Super Cap Providesabackuppowersourcetosustaincurrenttimeanddateduringapoweroutagelastingupto24hours .

    Battery back-upMaintainscurrenttimeanddateaduringpoweroutagelastinglongerthan24hours .AlsoenablesArmchairProgrammingofthecontrollerpriortoinstallation .

    Three independent watering ProgramsEnablesautomaticwateringProgramstobespecificallytailoredforvariousportionsofthelandscape;e .g .,lawns,shrubsandtrees .

    Three Start Timesper Program Enablesoperationofeachauto-maticProgramuptothreetimesperscheduledwateringday .

    Skip Days schedulingEnableswateringdaystobescheduledbyinterval,rangingfrom1(everyday)to31(onceevery31days) .

    Odd/Even date schedulingEnablesawateringdayscheduletobedefinedbyallodd-oreven-numberedcalendardays .

    Day Exclusion EnablesspecificweekdaystobeexcludedfromanOdd/EvendateorSkipDayswateringschedule .

    Program Stack/Overlap ProvidestheoptiontolimitoperationtooneProgram/stationatatime(Stack),orenableuptothreeProgramsorstationstooperateconcurrently .

    Station Test FeatureAconvenienttest-cyclefeatureoperateseachvalvestationinsequenceforaselectedruntimefrom110minutes .Perfect for new installations!

    Live programming Enablesprogrammingchangestobemadeatanytimeeven during watering!

    2

  • Fully automatic, semi-automatic and manual station operations .

    Manual AdvanceEnablesstationsequencetobeadvancedmanuallyduringoperation(manualorautomatic) .

    Off or Stop ImmediatelystopsandpreventsallwateringactivitywithoutdisturbingPrograms .

    Four places available to quickly remove start timesFourOFFpositionsareprovidedwithinthetimedisplaytoremoveunwantedstarttimes;significantlyreducingtheamountofscrollingrequired .

    Rain Delay Enablesautomaticwateringtobepostponedfrom1to9days;thenresumeautomaticallywateringasscheduled .

    Water BudgetEnablestheruntimeofallstationswithinaProgramtobescaledupto200%ordownto0%(Off) .Inaddition,aWaterBudgetvaluecanbeappliedtoindividualProgramsbyspecificmonthswhenseasonalwaterbudgetingispreferred .Thisisagreatfeatureforwatersmartapplications .

    MV/Pump control by station EnablesautomaticMasterValve/Pumpoperationtobecontrolledbyindividualstations .

    Station sequence delayProvidesanadjustabledelayperiodbetweenstationsduringtheoperatingsequencetoaccommodateslow-closingvalvesorarequiredwell-recoveryperiod .

    MV/Pump controlduring station delay EnablesMasterValve/Pumpoperationtobeactiveorinactiveduringastationdelayperiod .Rain Dial-R provides the choice!

    Built-in circuit protectionHelpsprotectthecontrollerselectroniccomponentsfromdamageduetopowerandnearbylightningsurges .

    Diagnostic Circuit Breaker Enablesthecontrollertodetectandbypassanystationwithashortcircuitorfaultysolenoid .DisplaysFUSandthebypassedstationnumberforeasytroubleshooting .

    Clear Program Memory EnablesProgrammemorytobeclearedandresetindependentlyofotherPrograms .

    Reset to Factory Program Defaults EnablesfactorydefaultProgramsettingstobeeasilyrestoredifrequired .

    3

  • F Getting Started

    Battery Installation & Armchair Programming

    Installinga9Vbattery(user-provided)servestwoimportantfunctions:first,itenablestheRainDial-Rtobefullyprogrammedpriortoinstallation,andsecond,itkeepsthecontrolmodulesynchronizedwithcurrenttimeanddateduringamainpowerinterruptionlastingmorethan24hours .Note: The battery is not capable of operating the sprinkler valves. Main AC power must be applied to the controller to enable operation.

    Thecontrolmoduleisdesignedtobeeasilyremovedforcompleteprogramminginamoreconvenientsetting,suchasyourfavoritearmchair .Toremovethecontrolmodule,simplyunplugtheribboncableconnectorfromtheprintedcircuitboard,thencarefullyremovethemodulefromitssnap-inhinges .TheRainDial-Rfeaturesnon-volatilememory,whichkeepstheprogramminginformationintact,evenifthebatterydiesorisdisconnected .

    Installing the Battery1 . Openthecontrollerdoor .

    2 . Pullthecontrolmoduleopenbygraspingitfromtherightedge(pressthemodulereleasetabontheoutdoormodel) .

    3 . Pressdownandoutwardontopofthebatterycompartmentcovertoremove .SeeFigure 1 .

    4 . Attachthebatterycliptoa9VAlakalinebattery .

    5 . Stowthebatteryintothecompartmentandreinstallthecover .

    6 . Thedisplaywillbeginflashing12:00 AM(pressanybuttontohalt) .

    Note: To begin setting up a watering Program, refer to Basic Programming Procedures on page 22.

    CAUTION: To avoid hazards from improper battery type installation, always replace the battery with the same or equivalent battery type . Always dispose of used batteries properly, as recommended by the battery manufacturer .

    4

  • EARTHGROUND

    MV/PUMP

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    5

    Figure 1

    9-Volt Alkaline Battery (not included)

    Battery Compartment Cover

  • Overview: Control Module Interface

    1 - Program Switch Three-positionslideswitchusedtoselectProgramA,BorC

    forsetup,programreviewandmanualoperation .

    2 - LCD Display High-contrastLCDpaneldisplaysallcontrollerprogramming

    andoperatinginformation .

    3 - Plus and Minus Buttons Pushbuttonsusedtoincreaseanddecreasedisplayvalues

    duringcontrollersetup,programmingandmanualoperations .Adjustsvaluesincrementally(pressandrelease)orbyrapidscrolling(pressandhold) .

    4 - Dial A25-positionrotaryswitchusedtoselectstations,starttimes,

    wateringdaysandspecialfunctionsforsetup,programmingandmanualoperations .

    5 - Manual Button Pushbuttonusedtostartandcontrolmanualoperations

    bystation .AlsoservesasaNextbuttontostepforwardthroughvarioussetup,programmingandmanualoperations .

    6 - Function Switch Athree-positionslideswitchusedtoselectoneofthree

    controllerfunctionmodes: Off or Stop -Stopsallcurrentwateringoperations,and

    preventsallautomaticandmanualoperations . Set Programs - Enablesautomaticwateringprogramsetup

    valuestobeselectedandchanged . Run or Manual - Normalswitchpositionforallautomaticand

    manualwateringoperations .

    7 - Semi-Auto Start Button Pushbuttonusedtomanuallystartanautomaticwatering

    Program .AlsousedtoinitiatetheStationTestRunoperation .

    6

  • 7

    Figure 2

    1

    2

    3

    4

    5

    6

    7

  • Overview: Internal Controller Components

    1 - Battery Compartment Snap-incoverprovideseasyaccessto9Valkalinebattery .

    2 - Control Module Ribbon Cable Quickdisconnectcablecontrolmodulefromcabinetfor

    ArmchairProgrammingorservice .

    3 - Earth Ground Terminal Wireconnectionterminalforearthgroundconductor .

    4 - Sensor Bypass Switch Switchcontrols(optional)rain/freezesensorinput . 5 - Safety Fuse 2ASlow-blowfuseprotectsagainstshort-circuitoverloadon

    the24VACinputpower .

    6 - Power Transformer Connection Terminals (24 VAC) Wireconnectionterminalsfor24VACplug-intransformer,

    andpowerconnectionpointfor(optional)CMR-KITremote . 7 - Valve Common Terminal (VC) Wireconnectionterminalforthevalve(field)commonwire .

    8 - Rain Sensor Terminals (Sensor) Wireconnectionterminalsfor(optional)IrritrolRainSensorTM

    modelRS500,RS1000,orRFS1000 .

    9 - Sensor Terminal Jumper Sensorterminaljumperwireremovedonlywhenarainor

    rain/freezesensorisconnected .)

    10 - Master Valve/Pump Terminal (MV/Pump) Wireconnectionterminalfor(optional)mastervalveorpump

    startrelay .(InstalledsensorterminaljumperwireremovedonlywhenRainSensorconnectionismade .)

    11 - Valve Station Terminals Valveconnectionterminalsoneterminalforeachvalve .

    (Terminallayoutvariesbymodel12-stationmodelshown .)

    12 - Handheld Remote Control Plug-in Port ModularconnectorportrequiredfortheIrritrolhandheld

    remotecontrolsystemmodelsCMR-KITorKSR-KIT-K .

    8

  • 9

    1 2 3 4

    5

    6

    7

    8

    9

    1011

    Figure 3

    12

  • F Installation Procedures

    wInstalling the Controller CabinetSelectashelteredlocationfortheindoormodelRainDial-Rsuchasagarageorserviceroom,preferablywithin5'(1 .5m)ofagroundedelectricaloutlet .Foroutdoorcontrollers,choosealocationthatpro-tectsagainstdirectexposuretosunandcontactwithirrigationspray,andisatleast5'(1 .5m)awayfromanymotorizedequipment .

    1 . Drivetheprovidedstainlesssteelscrewintoawallstudataconve-nientheight,leaving1/4"(6 .4mm)ofthescrewshaftexposed .

    Note: Use screw anchors when installing on drywall or masonry. 2 . Hangthecontrolleronthescrewusingthekeyhole-shapedslot .3 . Tosecurethecontroller,driveoneortwoscrewsthroughthe

    lowermountingholes . Note: The lower mounting holes in the Outdoor cabinet have a thin

    veneer that is easily pierced when installing the mounting screw during installation.

    wConnecting the Valve Control WiringForbestresults,useconnectionwirecablespecificallydesignedforautomaticirrigationsystems .Use18-AWGwireforconnectionsupto800'fromthecontroller,orheavier14-AWG(2 .0mm2)wireforcon-nectionsupto2000' .Aseparatewireforeachvalve(andrelay)con-nectionandatleastonecommon(return)wireisrequired .

    Note: If control wire conduit is required, install it at this time. For conduit installation, use the 3/4" (19mm) access hole in the indoor cabinet, or the threaded 1.25" NPT opening in the outdoor cabinet.1 . Routethecontrolwirefromthecontrollerlocationtothevalve(s) .2 . Attachaseparatecontrolwiretoeitherleadofeachvalvesolenoid .3 . Toprovideacommon(return)wire,attachtheremainingleadof

    eachvalvesolenoidtoasinglewire . Note: To prevent corrosion and a possible short circuit, use

    waterproof wire connectors on all external wire splices. For reference at the controller, note the wire color used for each

    valve connection and its corresponding watering zone.

    10

  • 4 . Routethecablethroughthelargestopeninginthebaseofthecontrollercabinetorthroughconduitifinstalled .Removethecablejackettoexposeabout8"ofwires .Carefullyremove3/8"ofinsulationfromtheendofeachwiretobeconnected .

    5 . Secureeachvalvewiretonumberedterminalinthepreferredoperatingsequenceorder .

    6 . ConnectthecommonwiretotheterminallabeledVC .7 . Ifapplicable,connectonelegofthemastervalveorpumpstart

    relaycontrolwiretotheterminallabeledMV/PUMP,andtheremaininglegtothevalvecommonwire .

    Note: The controller does not supply power to operate a pump. The pump start relay must have a nominal coil voltage of 24 VAC, rated at 0.375A maximum.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    11

    Figure 4

    Sprinkler Control Valves

    Common Wire

    Pump Start Relay or Master Valve

    1

    2

    3

    MV

    24V Relay

    Master Valve/Pump Terminal

    Valve Common Terminal

  • Connecting a Rain Sensor (optional) TheRainDial-RisdesignedtoworkinconjunctionwithIrritrolRainSensormodelsRS500,RS1000orRain/FreezesensorRFS1000torestrictwateringwhenmoistureand/ortemperaturelimitsaremet .Note: If connecting an alternate make of rain sensor, ensure it pro-vides normally-closed switch circuit operation.

    IMPORTANT: If a rain sensor is not installed, the sensor terminal jumper wire must remain in place, and the sensor switch must remain in the Bypass position . If either of these conditions are not met, automatic and manual operation will be disabled . 1 . Insertthesensorcablethroughthebottomofthecabinet .

    2 . LoosentheSensorterminalsandremovethejumperwire .

    3 . RefertotheinstallationinstructionsprovidedwiththeRainSensorandconnectwiresaccordingly .

    4 . PlacetheSensorswitchintheActiveposition . Note: When the Rain Sensor is active, all watering

    operations will be terminated and SEn (Sensor) will be displayed (in the current time dial position).

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    12

    Figure 5

    Jumper Wire Removed

  • Connecting a Remote Control Unit (optional)TheRainDial-Rcontrollerisremote-readyandisfullycompatiblewithbothIrritrolHandheldRemoteControlmodels:theclose-rangeresidentialmodelKSR-KIT-K,andthelong-rangecommercialmodelCMR-1-KIT .Bothhandheldremotesystemsoffersimilarcontrolfea-tures .Refertotheuserguideprovidedwitheachremotekitforcom-pleteinformation .

    Asshownintheillustrationbelow,theKSR-KIT-KreceiverplugassemblysimplyplugsintothereceptacleprovidedinthebackoftheRainDial-Rcontrolmodule .TheCMR-1-KITreceiverplugassemblyalsorequiresconnectiontothe24VACpowerterminals .

    Note: The receiver plug assembly of the two remote models look similar, but are not interchangeable.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    13

    Figure 6

    CMR-CC Receiver Plug for CMR-1-KIT Remote

    CA-03 Receiver Plug for KSR-KIT Remote

  • Connecting an Earth Ground DeviceNote: In order for the electrical surge components built into your Rain Dial-R to function properly, the controller must be connected to an earth ground device, such as a copper-clad ground rod or metal water pipe, using solid copper wire. This connection is especially important when the controller is installed in a lightning-prone area .

    1 . Connecta1216AWG(2mm21 .3mm2)solid-copperwiretothegrounddeviceandrouteintothecontrollerthroughanaccessopeninginthebaseofthecabinet .

    2 . SecurethegroundwiretotheterminallabeledEarthGround .

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    Metal Water Pipe

    8 (2 .4 m) Copper-clad Ground Rod (in moist soil)

    14

    Figure 7

  • Connecting the Power Supply - Indoor Models 1 . Routetheplug-intransformercablethroughthesmallhole

    providedinthebottomofthecabinet .

    2 . Tieaknotinthecabletoprovideastrainrelief,andconnectthewirestotheterminalslabeled24VAC(ineitherorder) .

    3 . Closethecontrolmoduleandplugthetransformerintoawalloutlet .Thecontrollerisnowreadytoprogramandoperate .

    Note: To immediately test-run the Rain Dial-R irrigation control system, refer to the Controller Station Test Feature on page 17.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    Figure 8

    15

    Strain-relief Knot

    Strain-relief Knot

    24 VAC, 30VA Transformer

  • Connecting the Power Source - Outdoor Models

    WARNING: All electrical components and connection methods must comply with all applicable national and local electrical codes including installation by qualified person-nel . These codes may require a junction box installed on controllers 1/2" (13mm) NPT nipple and a means in the fixed wiring of disconnecting AC power having a contact separation of at least 0 .120" (3mm) in the line and neutral poles . The connection wire must have insulation rated @ 105 C min .

    The controller must be connected to a grounded power source . Do not connect to one phase of a 3-phase power supply used by a pump or other electrical equipment .Prior to connecting controller wiring, verify that power has been turned off at the source by using an AC volt meter .1 . Installa1/2"(13mm)NPTconduitbodytothetransformerthread-

    edfitting .Fromtheconduitbody,installelectricalconduitroutingtotheACpowersource(perelectricalcode) .

    2 . Pull14AWGthroughtheconduitintotheconduitbody .

    3 . Usingtwist-onwireconnectors,attachthematingwiresasshowninFigure 10 .

    4 . Closeandsecuretheconduitbodycover .5 . Applypowertothecontrollerandcheckcontrolleroperation .If

    thecontrollerisnotoperating,disconnectthepoweratthesourceandhaveaqualifiedelectriciancheckforpossibleshortcircuit .

    CAUTION: For maximum protection of the controller electronic components when installed outdoors, always keep the cabinet cover closed and locked whenever possible . Store the cabinet keys in a safe, convenient location .

    16

    Figure 9

    Key

  • Controller Station Test Feature

    The controllerStation Test feature enablesyoutoquicklycheckforpropervalvestationoperationafterinitialinstallationorservice .Thetestcycleenablesallvalvestationstooperateinsequenceforatemporaryruntime,adjustablefrom110minutes .

    1 . PlacetheFunction switchintheSet ProgramsorRunposition .

    2 . TurntheDialtotheSkip Days - Special Functionsposition .

    3 . PresstheManualbutton(onetime)toselecttheTestRundisplayasshownatright .

    4 . A2-minutetestruntimeissetbydefault .Toadjusttheruntimefrom110minutes,pressthe or button .

    5 . PresstheSemi-Autobuttontostartthewateringcycle .Station1willturnon .

    6 . TurntheDialtotheCurrent Timeposition .Thedisplaywillindicatethecurrentclocktime(initially12:00PM)andstation1 .

    7 . Tomanuallyadvancethroughthestationoperatingsequence,presstheManualbutton .

    RD-1200

    A-+

    B-C-

    MANUAL

    TodaySun

    Mon

    Wed

    Thu

    2

    3

    4

    5

    6

    7

    8

    9

    1011123

    21

    PM

    SC

    HE

    DU

    LE

    STARTTIMES

    VA

    LV

    ER

    UN

    TIM

    ES

    17

    Figure 10

    1 2 3 4 5 6 7 8 9 10 11 12

    Equipment Ground to Green or Green/Yellow

    Hot or L2 to Black or Brown

    Neutral or L1 to White or Blue

    Conduit Body

    Electrical Conduit

  • F Getting the Most from Your Rain Dial-R Controller What is an Automatic Program Watering Cycle? AnautomaticwateringProgrambeginsatitsearliestassignedstarttimeonascheduledwateringday .ThelowestvalvestationnumberassignedtotheProgram,turnsonandoperatesthesprinklersforthespecifiedruntimeduration .Whenfinished,thenextvalvestationinnumericorder(withanassignedruntimeintheProgram)beginsoperation .TheProgramWateringCyclecontinuesuntilallvalvestationswithanassignedruntimeintheProgramhaveoperated . Why Three Programs? Atypicalresidentiallandscapeincludesvarioussectionsoflawn,shrubs,treesandgroundcover,allofwhichrequirewateringondifferentschedulesforoptimumplanthealthandconservation .Toaccommodatethis,theRainDial-RprovidesthreeindependentwateringPrograms:A,BandC .

    TheexamplebelowshowshowmultipleProgramscanbeusedtoeasilyaccomplishthis:

    Program Start Time Valve # Location Run Time Schedule

    A (#1)5:00AM 1 FrontLawn 15min. Odd 2 Backyard 15min. Odd 3 SideYard 10min. Odd B (#1)3:00PM 4 Trees(drip) 2hrs. Mon C (#1)4:00AM 5 Garden 5min. SkipDays,1 (#2)7:30PM 5 Garden 5min. SkipDays,1

    18

  • Avoid unexpected start times Itispossibletosetasecondstarttimethatbeginsbeforethewateringcyclefromthefirststarttimehasfinished .Whenthishappens,thestartofthesecondcycleisdelayeduntilthefirstiscomplete;sothestarttimemaynotoccurwhenyouexpectit .Inaddition,increasingruntimewiththewaterbudgetfea-turemaycauseanoverlapthatdelaysthenextscheduledstarttime .

    Avoid watering on a non-watering day AwateringcyclethatcontinuesbeyondMidnightwillruntocompletionregardlessifthenextdayisscheduledforwatering .

    Avoid excessive watering Bydefault,ProgramsA,BandCcanbescheduledtorunconcurrently(overlap) .ThisfeaturecanberestrictedbyselectingtheProgramStackingoption(seepage28) .Starttimesenteredforanyprogramwillbeginautomaticallywhenthattimeoccurs .Usingmultipleprogramsenablesvalvestationstowaterondifferentschedulesortoprovideadditionalwateringifoneprogramisnotenough .Ifyouneedextrawater,usemorethanonestarttimeand/orusetheWaterBudgetfeaturetoincreasethevalvestationruntime .

    Avoid Creating a low water pressure condition Starttimesassignedtodifferentprogramsareindependent .Ifyousetidenticaloroverlappingstarttimes,morethanonevalvestationcanrunatthesametime .Thetotalflowmayexceedtheavailablewatersupply .Toavoidthissituation,allowmoretimebetweenstarttimestoreducethenumberofvalvesrunningatonetime,andmakesurethatmultipleProgramsdonothavethesamestarttimes .

    Establishing new lawnsHavingshort,multiplewateringcycleseachdayisespeciallyusefulwhenestablishinganewlawn .

    Help with electrical problems TheRainDial-RwilldisplaythestationnumberandthewordFUSifashort-circuitonavalvestationisdetected .Thedetectedstationwillbebypassed,allowingtheremainingstationstorunintheProgramwateringcycle .

    19

  • F What the Display Indicates

    Thefollowingexamplesrepresentthedisplayinformationprovidedtoassistyouwithinthevariousprogramming,setupandoperatingmodes .

    Programming Mode (Function Set Programs) Current Time-Displaysthecurrenttimeofday .

    Valve Run Times-Displaystheruntimesetforaselectedvalvenumber .Willindicate0159minutes,1 .05 .9hoursorOff .

    Start Times-Displaysstarttime(s)assignedtotheselectedProgram .

    Today-DisplaysthecurrentdaywithinaWeekdayschedule,e .g .Su,Mo,etc .,orSkip Daysscheduleday(131) .

    Schedule-DisplaysONorOFF foreachdayinaWeekdayschedule .WhenusinganOdd/Evenschedule,Odd,EvenorOFFwillbedisplayedforeachstation .WhenusingaSkip Daysschedule,Once Every (0131) willbedisplayed .

    Special Functions (Dial Special Functions)

    Station Test Cycle-Allactivestationnumberswillbeshownatthetopofthedisplay .T:0110indicatesminutesofruntimeselectedfortestcycle .

    Water Budget (Per Program)-Displaysthecur-rentWaterBudget%orOFF .IfaMonthlyWaterBudgetisinuse,( )willbeshown .

    Clear Program Memory-CLrindicatestheClearProgramMemoryfunctionisselected .

    Well Recovery Time-Indicatesthedelaytime(0059seconds,159minutesor12hours)settooccurbetweenstationsinawateringcycle .

    20

    1 2 3 4 5 6 7 8 9 10 11 12

  • Pump Operation during Station Delay -IndicatespumpoperationissettoOnorOffduringastationdelayperiodperiod .

    Program Stacking/Overlap-IndicatesProgramStacking(1:On)orOverlap(3:On) optionselected .

    Odd/Even Schedule -IndicatesOddorEvnscheduleselected .

    Calender month -Displaysthecurrentmonth .

    Calender month/day -Displaysthecurrentmonthandday .

    Year -Displaysthecurrentyear .

    Rain Delay-Indicatesnumberofdays(09)settodelayautomaticoperation .

    Monthly Water Budget -IndicatesWaterBudgetstatus(On/Off)permonth(112)and%factor(01200orOff)assignedtoeachmonth .(Month,dayandyearmayalsobesetatthistime .)

    Run Mode (Function Run) Automatic Mode (Dial Current Time)-Active

    valvenumberandcurrenttimeareshown .(Dial Active valve number)-activevalvenumber,currentProgramandremainingruntime .

    Note: If Water Budget is active, the adjusted run time will be shown.

    Manual Mode-(Dial Active valve number)-Valvenumber,M:andremainingruntimeareshown .

    Rain Delay-OF(Off)andthenumberofdaysuntilwateringresumesalternateswiththecurrenttime .

    Diagnostic Circuit Breaker-FUS(Fuse)andthebypassedvalvenumber(s)willalternatewiththecurrenttime .

    21

  • F Basic Programming Procedures

    Setting the Current Time and Day

    1 . PlacetheFunction switchintheSet Programs(center)position .

    2 . TurntheDialtotheCurrent Timeposition .

    3 . Pressthe or buttontosetthecurrenttime(noteAM/PM) .

    Note: When using the or button, press and release to adjust in steps, or press and hold to scroll.

    4 . TurntheDialtotheTodayposition .

    5 . Pressthe or buttontoselectthecurrentday(abbreviation) .

    Note: If Odd/Even schedule or Monthly Water Budget is used, the current day of the week is preset and cannot be changed.

    6 . ReturntheDialtotheCurrent Timeposition .

    7 . ReturntheFunction switchtotheRunposition .

    Note: The flashing colon (:) indicates AC power is present. If the colon is not flashing, the controller is operating on battery power only.

    Setting the Valve Run Time Duration

    EachvalvestationcanhaveanindividualruntimeassignmentineachProgram .Runtimecanbesetfor159minutes(in1-minuteincrements)or15 .9hours(in1/10-hourincrements) .

    1 . PlacetheFunction switchintheSet Programs(center)position .

    2 . SelectProgramA,BorC .

    3 . TurntheDialtoselectthevalve number .

    4 . Pressthe or buttontosetthevalveruntimeduration .

    5 . Repeatsteps3and4forallvalvestobeassignedtotheselectedProgram .

    6 . Repeatsteps25foreachProgramasneeded .

    7 . Whenfinished,returntheDialtotheCurrent Timeposition .

    8 . PlacetheFunction switchintheRunposition .

    22

  • Setting the Program Cycle Start Time(s)EachProgramcanhavethreeseparatestarttimes .Formaturelandscapes,onestarttimeperProgramisgenerallysufficient .Whenestablishinganewlawn,usingtwoorthreestarttimeswithshortvalveruntimescanprovidetheadditionalirrigationrequiredforgrow-in,atareducedratetohelppreventrunoffanderosion .1 . PlacetheFunction switchintheSet Programsposition .2 . SelectProgramA,BorC .3 . TurntheDialtoselectStart Time 1 (2 or 3) .4 . Pressthe or buttontosetthestarttime(noteAM/PM) . Note: To remove a start time, select Off, displayed between

    11:5912:00 and 5:596:00 (AM and PM).5 . Repeatsteps3and4tosetadditionalstarttimesforthisProgram .6 . Repeatsteps25foreachProgramasneeded .7 . Whenfinished,returntheDialtotheCurrent Timeposition .8 . ReturntheFunction switchtotheRunposition .

    Setting the Program Watering Day Schedule

    WateringdayscanbescheduledforeachProgramusingoneofthefollowingmethods: Weekdays-Scheduleswateringforspecificdaysoftheweek . Skip Day-Scheduleswateringdaysbyintervalfrequency;

    e .g .,everyday(01),every-other-day(02)etc . Odd/Even Date-ScheduleswateringdaysbasedonOdd-or

    Even-numberedcalenderdays .To set a Weekdays Schedule:1 . PlacetheFunction switchintheSet Programsposition .2 . SelectProgramA,BorC .3 . TurntheDialtothedesiredweekdayposition .4 . Pressthe buttontoselecttheday(On),orthe button

    removetheday(Off)fromthewateringdayschedule .5 . Repeatsteps3and4toscheduleadditionalweekdaysasneeded .6 . Repeatsteps25foreachProgramasneeded .7 . Whenfinished,returntheDialtotheCurrent Timeposition .8 . ReturntheFunction switchtotheRunposition .

    23

  • Note: Each Program can have a Skip Days or an Odd/Even Date watering schedule, but not both. One schedule must be turned off to enable the alternate schedule to be selected.

    To Set a Skip Day Schedule:1 . PlacetheFunction switchintheSet Programsposition .

    2 . SelectProgramA,BorC .

    3 . TurntheDialtotheSkip Days/Special Functions position .

    4 . Pressthe / buttonstoselecttheSkip Day interval(0131) days .

    Note:To turn Off a Skip Day schedule, press the or button to display OFF.

    5 . TurntheDialtotheToday position .

    6 . Pressthe / buttonstoselectthecurrentdaywithintheSkipDayintervalschedule .

    Note: For example, if you have selected a 3-day schedule, and prefer to have watering start today, select 03. To water tomor-row, select 02. To watering in three days, select 01.

    7 . Repeatsteps26foreachProgramasneeded .

    8 . Whenfinished,returntheDialtotheCurrent Timeposition .

    9 . ReturntheFunction switchtotheRunposition .

    To Set an Odd/Even Date Schedule:1 . PlacetheFunction switchintheSet Programsposition .

    2 . SelectProgramA,BorC .

    3 . TurntheDialtotheSkip Days - Special Functions position .

    4 . PresstheManualbutton(seventimes)todisplaydashes( ) .

    5 . Pressthe buttontoselectOdd,orthe buttontoselectEven (EVn) .

    Note:To turn Off an Odd/Even Date schedule, press the or button to display dashes ( ).

    6 . PresstheManualbutton(onetime)toselectthecalendarMonth January(JA)willbedisplayed .

    24

  • 7 . Pressthe / buttonstoadjustthemonthsetting . JA-January,Fe-February,MR-March,AP-April,My-May,

    JN-June,JL-July,AU-August,SE-September,OC-October,nO-November,andDE-December .

    8 . PresstheManualbutton(onetime)toselecttheDaysetting .9 . Pressthe / buttonstoselectthecurrentcalendarday .

    Example: September 17th would be displayed as S:17.10 .PresstheManualbutton(onetime)toselecttheYearsetting .11 .Pressthe / buttonstoselecttheyear(09 =2009) .

    13 .Whenfinished,returntheDialtotheCurrent Timeposition .12 .Repeatsteps210foreachProgramasneeded .14 .ReturntheFunction switchtotheRunposition .Note: When an Odd/Even schedule is used, confirm that the current day of the week is correctly set by turning the Dial to the Today position. If the day of the week is incorrect, adjust the month, day and year settings to properly synchronize the controller. Also note that when using an Odd/Even schedule, watering never occurs on the 31st of any month or February 29th of a leap year.

    Day Exclusion FeatureWhenusingaSkipDaysandOdd/Evendatewateringschedule,wateringwillnotoccuronthesamedaysfromweektoweek .Torestrictwateringonspecificweekdays;e .g .,forscheduledmowingormaintenance,usetheDayExclusionfeatureasfollows:

    1 .PlacetheFunction switchintheSet Programsposition .2 . SelectProgramA,BorC .3 . TurntheDialtotheDay tobeexcluded .4 . Pressthe buttondisplayOFF .5 . Repeatsteps3and4toexcludeadditionaldays .6 . ReturntheDialtotheCurrent Time position .7 .ReturntheFunction switchtotheRunposition .

    v This completes the basic programming requirements for automatic operation . To utilize the various Rain Dial-R Special Functions, continue on pages 2629 .

    25

  • F Special Functions

    Rain Delay

    TheRain Delay feature enablesautomaticwateringoperationtobesuspendedforaperiodof1to9days;thenresumewateringautomaticallyasscheduled .

    1 . PlacetheFunction switchintheSet Programs position .

    2 . TurntheDialtotheSkip Days - Special Functionsposition .

    3 . PresstheManualbutton(repeatedly)todisplayrd0 (RainDelay=0days) .

    4 . Pressthe / buttonstoselectaRainDelayperiodof1to9days .

    5 . ReturntheDialtotheCurrent Timeposition .

    6 . ReturntheFunction switchtotheRun position .

    Note: When the Rain Delay function is active, the display will alternately indicate the current time of day and the number of days remaining until automatic operation resumes. To cancel Rain Delay at any time, decrease Rain Delay setting to 0 days.

    Water Budget

    TheWater Budgetfeatureenablestheruntimeofallstations,assignedtoaspecificProgram,tobesimultaneouslyadjustedupordownbypercentage .Fromthebaselineof100%,runtimescanbereducedto0%(Off)orincreasedupto200% .

    Toreducethepossibilityofover-wateringwhenselectingaWaterBudgetvalueabove100%,theadjustedruntimeisautomaticallycutinhalf,andthewateringcycleruntwice .Forexample,adjustingto200%wouldfirstincreasea20-minutestationruntimeto40min-utes,thensplitthetimeinhalfandruntwowateringcyclesback-to-backwith20minutesduringeachcycle .

    Allzoneruntimesareretainedinthetimermemoryandreturnedtotheirsetvaluewhentheseasonadjustisresetto100% .Theonlytimeastationruntimewillappearchangedisduringoperation .

    26

  • Foradditionalcontrol,aWaterBudgetfactorcanbeassigneduni-versallytoaProgram,orappliedtoaProgrambyspecificmonthsoftheyearwhenWaterBudgetingbyseasonaldemandispreferred .

    Note: Each Program is limited to one Water Budget method at a time. Applying a Water Budget by monthly demand will override a basic Water Budget adjustment value. Conversely, to apply a basic Water Budget, all months must be set at 100%.

    To Apply a Basic Water Budget:

    1 . TurntheDialtotheSkip Days - Special Functionsposition .

    2 . SelectProgramA,BorC .

    3 . PlacetheFunction switchintheSet Programs position .

    4 . PresstheManualbutton(twice)todisplay100 (%) .

    5 . Pressthe or buttontoadjustthe%factor(10%increments) .

    Note: Decreasing the Water Budget value beyond 10% to OFF prevents the Program from running automatically.

    6 . ReturntheDialtotheCurrent Time position .

    7 . ReturntheFunction switchtotheRunposition .

    To Apply a Monthly Water Budget:

    Note: Applying a monthly Water Budget requires the current date to be set. If an Odd/Even watering schedule has been assigned, the current date was established during the procedure. Steps 111 in the following procedure establishes the current date. To bypass this portion of the procedure, begin at step 12 on page 28.

    1 . TurntheDialtotheSkip Days - Special Functionsposition .

    2 . SelectProgramA,BorC .

    3 . PlacetheFunction switchintheSet Programs position .

    4 . PresstheManual buttonrepeatedlytoselect theMonthlyWaterBudgetdisplayasshownatright .

    5 . Pressthe buttontoselectON .

    27

    1 2 3 4 5 6 7 8 9 10 11 12

    1 2 3 4 5 6 7 8 9 10 11 12

  • 6 . PresstheManualbuttononetimetoselectthecalendarMonthsetting .January(JA)willbedisplayed .

    7 . Pressthe or buttontoselectthecurrentmonthabbreviation:JA-January(1),Fe-February(2),MR-March(3),AP-April(4),My-May(5),JN-June(6),JL-July(7),AU-August(8),SE-September(9),OC-October(10),nO-November(11)andDE-December(12) .

    8 . Withthemonthselected,presstheManual buttononetimetoselecttheDaysetting .

    9 . Usethe / buttonstoselectthecurrentcalendarday .For example, April 4 would be displayed as A:04.

    10 .PresstheManual buttononetimetoselecttheYearsetting .

    11 .Pressthe / buttonstoselectthecurrentyear(09=2009) .

    12 .PresstheManual button(asneeded)toselecttheMonthlyWaterBudgetdisplay .1(January)isselectedwithitscurrentWaterBudgetvalue(100%bydefault) .

    13 .Tochangethemonthselection,presstheManualbutton .

    14 .Pressthe / buttonstoadjustthe%factorin1%incrementsdownorup(Offor10%200%) .

    15 .Repeatsteps13and14tosetadditionalmonths .

    15 .Whenfinished,returntheDialtotheCurrent Timeposition .

    16 .ReturntheFunction switchtotheRunposition .

    Stack/Overlap

    TheStack/Overlap optiondetermineshowthecontrollerwillmanageconcurrentlyscheduledprogramsormanuallystartedvalvestations .Bydefault,theOverlapoptionisselected,enablingsimultaneousoperationofuptothreeProgramsormanualvalvestations .SelectingtheStackoptionlimitsoperationtoeitheroneautomaticProgramormanualvalvestation .

    28

  • Important: The Stack option prevents a scheduled Program or manually

    operated valve station from operating until any current opera-tion has been completed or canceled. At midnight, any remaining scheduled Programs stacked in queue will be canceled.

    Selecting the Overlap option can cause the electrical and/or hydraulic capacity of your irrigation system to be exceeded. Always plan your watering schedule carefully!

    1 . TurntheDialtotheSkip Days - Special Functionsposition .

    2 . PlacetheFunction switchintheSet Programs position .

    3 . PresstheManualbuttonrepeatedlytodisplay3:On (threeprogramsorstationscanrunconcurrently) .

    4 . ToselecttheStackoption,pressthe / buttontochoose1:On .

    5 . ReturntheDialtotheCurrent Time position .

    6 . ReturntheFunction switchtotheRunposition .

    Station Delay

    Irrigationsystemsthatutilizeawell-watersourceorhaveslow-closingvalves,mayrequireadelayperiodtooccurbetweencon-secutivestationsduringawateringcycle .TheStationDelayfeatureenablesadelayperiodtobesetfrom1secondto2hours .1 . PlacetheFunction switchintheSet Programsposition .

    2 . PlacetheProgramswitchtoselectA,BorC .

    3 . TurntheDialtotheSkip Days - Special Functions position .

    4 . PresstheManualbuttonrepeatedlytodisplayW:00 (nodelay) .

    5 . Pressthe / buttonstosetthedelaytime:0059seconds,0159minutes(MIN)or1 .02 .0hours(HR .) .

    Note: Hold the button down to scroll. The display will continuously scroll from seconds to minutes to hours (:00 = no delay time).

    6 . ReturntheDialtotheCurrent Time position .

    7 . ReturntheFunction switchintheRunposition .

    29

  • Pump Control During Station Delay

    ThePumpControlfeatureisgenerallyusedinconjunctionwiththeStationDelayfeature,enablingthepump/mastervalvetobeturnedonoroffbetweenconsecutivestationsduringawateringcycle .Forexample,asystemwithslow-closingvalvesmayrequireanauxiliarypumptoremainonthroughoutthewateringcycletoassistvalveclosure .Alternately,asystemutilizingawell-watersupplysourcemayrequiretheauxiliarypumptobeoffwhenanextendeddelayperiodbetweenstationsisrequiredforadequatewell-recoverytime .

    1 . PlacetheFunction switchintheSet Programsposition .

    2 . PlacetheProgramswitchtoselectA,BorC .

    3 . TurntheDialtotheSkip Days - Special Functions position .

    4 . PresstheManualbutton(repeatedly)todisplayP:OF (PumpOff) .

    5 . Pressthe / buttontotogglebetweenP:OFandP:On

    6 . ReturntheDialtotheCurrent Time position .

    7 . ReturntheFunction switchintheRunposition .

    Pump Control Option

    Bydefault,thepumpcontrolcircuitisactivatedsimultaneouslywithanyautomaticormanualvalvestationoperation .Whenpumpoper-ationisnotrequiredforspecificvalvestations;e .g .,dripirrigation,thepumpcontrolcircuitcanbeeasilydisabledasneeded .

    Note: The Pump control option applies to the selected valve station regardless of its Program assignment.

    1 . PlacetheFunction switchintheSet Programsposition .

    2 . TurntheDialtoselecttheappropriatevalvestationnumber .

    3 . PresstheManualbutton:P:On(PumpOn)willbedisplayed .

    4 . Todisablethepumpcontrolcircuitfromthevalvestation,pressthe buttontodisplayP:OF (PumpOff) .

    5 . Repeatsteps24foradditionalvalvestationsasrequired .

    6 . ReturntheDialtotheCurrent Time position .

    7 . ReturntheFunction switchtotheRunposition . 30

  • F Diagnostic Circuit Breaker

    ThepromptFUSandthemalfunctioningvalvestationnumberwillbealternatelydisplayedwiththecurrenttime .Thevalvestationwillbebypassedduringthewateringcycle,enablingallremainingvalvestationstorunasscheduled .WiththeDialsetintheCurrent Time position,pressanybuttontocleartheFUSdisplay .

    Important:Determine the cause of the malfunction and take corrective action as necessary . Clearing the display will not resolve the problem .

    F Fuse Replacement

    Caution: The 2 .0A safety fuse protects the transformer from damage due an excessive current load (short circuit) condition . Locate and eliminate the cause of the problem before replac-ing the fuse . For continued protection against risk of fire, replace only with the same fuse type and rating .

    1 . Disconnectpowertothecontroller .2 . Carefullyremovethesafetyfusefromtheterminalboard(see

    page9forfuselocation) .

    3 . Installanew2 .0Aslow-blowfuse,ensuringthatitisproperlyseatedintheretainingclip .

    4 . Reconnectpowertothecontroller .

    31

  • F Manual Operations

    Semi-automatic Program Operation

    Semi-AutomaticProgramoperationenablesanautomaticProgramwateringcycletobestartedmanuallyatanytime .Oncerunning,themanualadvancefeatureenablesyoutostepthroughthepro-grammedstationsequence .

    1 . PlacetheFunction switchintheRunposition .

    2 . TurntheDialtotheCurrent Time position .

    3 . PlacetheProgramswitchtoselectA,BorC .

    4 . PresstheSemi-Autobuttontostartthewateringcycle .

    Note: Once started, the station sequence can be manually advanced by placing the Dial to Current Time and pressing the Manual button.

    Note: The Manual Advance feature applies to all Automatic, Semi-automatic and Station Test watering operations for the selected Program.

    Note: To terminate watering operations, place the Function switch momentarily in the OFF or Stop position.

    32

  • Manual Station Operation

    Manualstation operationprovidesmanualcontrolattheindividualstationlevelandprovidesthefollowingfourcontroloptions:

    Station(s)canbeoperatedforaone-timerundurationwithoutalteringthestationssetruntimeinanautomaticProgram .

    Operationcanbelimitedtoonlyonestationrunningmanuallyorsettoallowthreestationstorunatthesametime .

    Note: Refer to Stack/Overlap Option on page 26 for additional information regarding manual operations.

    WorkswiththeManualAdvancefeaturetomoveupthroughthestationsequence .

    1 . PlacetheFunction switchintheRunposition .

    2 . TurntheDialtotheStation Number tobemanuallyoperated .

    3 . Usethe / buttonstosetamanualoperationruntimerangingfrom1minuteto5 .9hours .

    4 . PresstheManual buttontostarttheoperation .

    5 . Ifthisistheonlystationtoberunmanually,skipstep6andcontinueatstep7below .

    6 . Toaddadditionalstationstothemanualrunoperation,repeatsteps2through4asneeded,thencontinueatstep7 .

    Note: Depending upon the Stack/Overlap setting, additional stations selected (beyond the one or three option setting) will register as OFF when entered with the Manual button. However, they will be placed (stacked) in the manual sequence to run.

    7 . TurntheDialtotheCurrent Timeposition .

    Note: Once started, the station sequence can be manually advanced by pressing the Manual button.

    Note: To terminate manual watering operations, place the Function switch momentarily in the OFF or Stop position.

    33

  • 34

    F Clear Program Memory

    TheClear ProgramMemoryfeatureenablesyoutosafelycleartheautomaticwateringprogramsettingsdefinedforaspecificProgramwithoutaffectinganyremainingPrograminformation .ThememoryerasefunctionappliesonlytothespecifiedProgram,leavingtheremainingProgramsintact .

    Important:The Clear Program function completely erases all user-defined programming information from the selected Program including: start times, run times, and watering day schedule .

    Note: To return the Program back to factory default settings, refer to Reset Factory Default Programming on page 35.

    1 . PlacetheFunction switchintheSet Programsposition .

    2 . PlacetheProgramswitchtoselectA,BorC .

    3 . TurntheDialtotheSkip Days - Special Functions position .

    4 . PresstheManualbuttonrepeatedlytodisplayCLr (Clear) .

    5 . Pressthe buttononetime .Thedisplaywillshowtheprompt:CL?(Clear?) .

    6 . Tocompletetheprocess,pressthe buttonagaintodisplaythepromptEnd .

    7 . ReturntheDialtotheCurrent Time position .

    8 . ReturntheFunction switchtotheRunposition .

  • 35

    F Restore Rain Dial-R to Factory Default Settings

    TheRainDial-Rfactorydefaultsettingsforautomaticprogramoperationareasfollows:CurrentTime:12:00AM .CurrentDay:Sunday .CurrentDate:January1,2008 .ProgramA:Weekdaywateringschedulewithalldaysactive . Onestarttimeat7:00AM . 10-minuteruntimeonallvalvestations .ProgramBandC:Nowateringdays,stationruntimesorstarttimes .SkipDaysandOdd/Evendayschedule:OFF-allPrograms .ExcludeddaysinSkipDaysorOdd/Evenschedule:None .MV/Pumpoperation:ON-allstations .WellRecoveryperiod:00(OFF)-allPrograms .MV/PumpoperationduringWellRecovery:OFF-allPrograms .WaterBudget:100%-allProgramsandmonths .RainDelay:0days .Stack/Overlap:Overlap-3Programsor3manualstations .

    To restore factory default settings:1 . PlacetheFunction switchintheSet Programposition .2 . PlacetheProgramswitchtoselectProgramB .4 . Openthebatterycompartmentanddisconnectthebattery .3 . LeavingtheACpowerconnected,carefullyunplugthecontrol

    moduleribboncablefromtheterminalBoardsocket .5 . PressandholdtheManualbutton .6 . PlugintheribboncableandreleasetheManualbutton . Note: With the dial in the Current Time position, the display

    should now show 12:00 AM. If it does not, repeat the procedure as necessary.

    7 . Connectthebattery .8 . Reprogramthecontroller .

  • 36

    Problem

    Displayblank .

    Somevalvesdonotoperate .

    Novalvesoperate .

    Wateringonwrongday .

    Currenttimeiswrongandflashing .

    FUSandastationnumberalternateswithcurrenttime .

    Valvewillnotturnoff(withFunctionSwitch .intheOFFposition) .

    SENalternateswithtimeofday .

    Possible Cause

    Nopower .

    Faultyorimpropervalvewireconnections .

    Debrisinvalve .

    FunctionswitchOFF .

    Faultyvalvecommonwireconnection .

    Sensorswitchin Activepositionnosensororjumperconnected .

    Nostarttimeset .

    Wateringdayschedulesetincorrectly .

    Powerinterruptionwithoutbatterybackup .

    Shortorover-currentonvalvestation .

    Valvemalfunction .

    Wateringonholdduetosensoroperation .

    Correction

    Checktransformer/powerconnections,2Afuse,andACpower .

    Checkandcorrectallvalvewireconnections .

    Inspect,clean/replacevalvesolenoid/plungeranddiaphragm .

    SetswitchtoRun .

    Check/correctvalvecommonconnection .

    SetswitchtoBypassorinstallterminaljumper .

    SetProgramstarttime .

    Correctwateringdayscheduleasneeded .

    Install/replacebattery,resetcurrenttime .

    Check/replacevalvesolenoidandsplices .

    Inspect,clean/replacevalvesolenoid/plungeranddiaphragm .

    Normaloperationforsensor .SetSensorswitchtoBypass .

    F Troubleshooting

  • 37

    F Contact Information

    Thetroubleshootingsolutionsareprovidedtohelpresolveproblemsthatmayariseduringsetupand/oroperationoftheRainDial-Rcontroller .

    Iftheproblemisnotlistedorcannotberesolvedwiththeprovidedsolutions,contactanauthorizedIrritrolproductexpertforassistanceviaphoneoremail .

    U .S ./Canada:

    Phone:1-800-634-8873(7:30am4pm,MF,PT)

    E-mail:irrigationsupport@irritrol .com

    Europe:

    Phone:+39-076540191

    E-mail:intlirrigationsupport@irritrol .com

    Australia:

    Phone:+61883003633

    E-mail:intlirrigationsupport@irritrol .com

  • F Specifications

    Outdoor Models: Input:120VAC60Hz,30VA(Domestic), 230/240VAC,50Hz,30VA(International)Indoor Models: Input(fromplug-intransformer):24VAC,60Hz,30VA (domestic),24VAC,50Hz,30VA(InternationalandAustralian)

    All Models: StationOutput:24VACat0 .5A,1 .0A(maximumtotal) MasterValve/PumpStartRelayOutput:24VACat0 .375A 2 .0ASlow-blowFuse BatteryBack-up(time,dayanddate) Operatingtemperaturerange:32Fto140F(0Cto60C)

    Caution: The Rain Dial is designed to operate 24 VAC valve solenoids rated at 0 .25A (6 VA) . Total current load during operation must not exceed 1 .0A . A maximum of two solenoids per station terminal may be used if the total station load does not exceed 0 .5A . No more than three solenoids (plus MV/Pump circuit) should operate concurrently . In irrigation systems where multiple controllers are used, each controller must utilize a sepa-rate valve common circuit .FCC Rules - Domestic: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdig-

    italdevice,pursuanttoSubpartJofPart15oftheFCCRules .Theselimitsaredesignedtoprovidereasonable

    protectionagainstharmfulinterferenceinaresidentialinstallation .Thisequipmentgenerates,usesandcan

    radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycause

    harmfulinterferencetoradiocommunications .However,thereisnoguaranteethatinterferencewillnotoccur

    inaparticularinstallation .Ifthisequipmentdoesharmfulinterferencetoradioortelevisionreception,which

    canbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterfer-

    encebyoneormoreofthefollowingmeasures:

    1 . Reorientorrelocatethereceivingantenna .

    2 . Increasetheseparationbetweentheequipmentandreceiver .

    3 . Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected .

    4 . Consultthedealeroranexperiencedradio/TVtechnicianforhelp .

    TheusermayfindthefollowingbookletpreparedbytheFederalCommunicationsCommissionhelpful:

    HowToIdentifyandResolveRadio-TVInterferenceProblems .ThisbookletisavailablefromtheU .S .

    GovernmentPrintingOffice,Washington,DC20402,stock#004-000-00345-4 .

    International:ThisisaCISPR22ClassBproduct .

    2008Irritrolwww .irritrol .com FormNumber373-0502Rev .A

  • Controlador de sistemas de riego

    Gua del usuario Configuracin Instalacin Programacin Solucin de

    problemas

    v Modelos para interiores y exteriores de 6, 9 y 12 estaciones v

    English

    Espaol

    Franais

  • Introduccin al controlador Rain Dial . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

    Cmo empezar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    Instalacindelapilayprogramacindesdecasa . . . . . . . . . . . . . . .4-5

    Descripcingeneral:Interfazdelmdulodecontrol . . . . . . . . . . . . . .6-7

    Descripcingeneral:Componentesinternosdelcontrolador . . . . . . .8-9

    Procedimientos de instalacin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-15

    InstalacindelarmariodelControlador . . . . . . . . . . . . . . . . . . . . . . . . 10

    Conexindelcableadodecontroldelasvlvulas . . . . . . . . . . . . . .10-11

    Conexindeunsensordelluvia(opcional) . . . . . . . . . . . . . . . . . . . . . 12

    Conexindeunaunidaddecontrolremoto(opcional) . . . . . . . . . . . . . 13

    Conexinaunatomadetierra . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Conexindelsuministroelctrico . . . . . . . . . . . . . . . . . . . . . . . . . . .15-17

    Modelosparainteriores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Modelosparaexteriores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17

    Pruebadeestaciones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    Cmo obtener los mejores resultados de su programador Rain Dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-19

    Ejemplodeunplanderiego . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Indicaciones en pantalla . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-21

    Procedimientos bsicos de programacin . . . . . . . . . . . . . . . . . . . . .22-25

    Ajustedelafechaylahoraactuales . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    Ajustedeltiempoderiegodelasvlvulas . . . . . . . . . . . . . . . . . . . . . . 22

    Ajustedelashorasdearranquedelosprogramas . . . . . . . . . . . . . . . 23

    Ajustedelcalendariodedasderiego . . . . . . . . . . . . . . . . . . . .23-25

    ParaprogramaruncalendariodeltipoDasdelasemana: . . . . . . 23

    ParaprogramaruncalendariodeltipoSaltarDas: . . . . . . . . . . . . 24

    ParaprogramaruncalendariodeltipoDaspares/impares . . . .24-25

    Exclusindedas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    ii

    FContenido

  • Funciones especiales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-29

    Suspensintemporalporlluvia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    Ajustesporcentuales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-28

    ParaaplicarunAjusteporcentualbsico: . . . . . . . . . . . . . . . . . . . 27

    ParaaplicarunAjusteporcentualmensual: . . . . . . . . . . . . . . . .27-28

    Apilamiento/Solapamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Retardoestacin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    ControldelabombaduranteelperiododeRetardoestacin . . . . . . . 30

    OpcindeControldelabomba . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Interruptor automtico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Sustitucin de fusibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Operaciones manuales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3233

    Operacinsemiautomticadeprogramas . . . . . . . . . . . . . . . . . . . . . . 32

    Operacinmanualdeestaciones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Borrar la memoria de programas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    Restaurar los Ajustes predeterminados de fbrica del Rain Dial-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Solucin de Problemas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Informacin de contacto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Especificaciones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Normativa FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    1

  • F Introduccin al controlador Rain Dial

    Para obtener las mximas ventajas de su nuevo controlador Rain Dial-R, dedique unos momentos a familiarizarse con sus muchas funciones:

    Diseo modular Facilitaelaccesoalosterminalesdeconexindelasvlvulasyalcompartimientodelaspilas .Elmdulodecontrolencajaapresinypuederetirarsefcilmenteparalaprogramacin"desdecasa" .

    Preparado para el control remoto IncorporaunconectorRJ-11paralaconexindirectadelossistemasdecontrolremotodemanoIrritrolCMR-KIToKSR-KIT .

    Memoria no voltil Guardalainformacindelosprogramasderiegoenmemoriaduranteaos sin electricidad!

    Super Cap" Unafuentedealimentacinderespaldoquemantienelafechaylahoraactualesdurantehasta24horasencasodeuncortedeenergaelctrica .

    Pila de respaldo Mantienelafechaylahoraactualesdurantecortesdeenergaelctricademsde24horas .Asimismo,permiteprogramarelcontroladorantesdeinstalarloconelsistema"ArmchairProgramming" .

    Tres programas de riego independientes Permitedisearprogramasderiegoautomticoespecficamenteparadiferenteszonaspaisajsticas,porejemplo,cspedes,arbustosorboles .

    Tres horas de arranque por programa Permiteponerenmarchacadaprogramaautomticohastatresvecesencadadaderiegoprogramado .

    Programacin Saltar Das Permiteprogramarlosdasderiegoporintervalos,desde1(todoslosdas)a31(unavezcada31das) .

    Programacin en das Pares/Impares Permitedefinirunprogramaderiegosolamenteendasparesosolamenteendasimpares .

    Exclusin de das PermiteexcluirdasespecficosdeunprogramadedasPares/imparesoSaltarDas .

    Apilamiento/Solapamiento de programas Permiterestringirlaoperacinaunasolaestacinounsoloprogramaalavez(apilamiento)ohabilitarhastatresProgramasotresestacionesdeformaconcurrente(solapamiento) .

    Funcin Prueba de estaciones Unacmodafuncindeprueba,queponeenmarchacadaestacinsecuencialmenteduranteuntiempoderiegoseleccionado,de1a10minutos .Perfecto para instalaciones nuevas!

    Programacin en tiempo real Permitemodificarlaprogramacinencualquiermomentoincluso durante el riego!

    2

  • Activacin de estaciones en modo automtico, semiautomtico y manual . Avance manual Permiteavanzarmanualmentelasecuenciadeestaciones

    durantelaoperacin(manualoautomtica) .

    Desconectado o Stop Detieneinmediatamentetodaactividadderiegosinmodificarlaprogramacin .

    Cuatro opciones para eliminar rpidamente horas de arranque Existencuatroposicionesde"Desconectado"enlapantalladehorasdearranque,quepermiteneliminarhorasdearranquenodeseadas,reduciendodeformasignificativalosdesplazamientosnecesarios .

    Suspensin temporal por lluvia Permitesuspenderelriegoautomticoduranteunperiodode1a9das,yluegoreanudarautomticamenteelriegoprogramado .

    Ajuste porcentual PermiteajustarproporcionalmenteeltiempoderiegodetodaslasestacionesdeunProgramadesde0(desactivado)a200% .Adems,puedeaplicarseunAjusteporcentualaprogramasindividualesenmesesespecficossisedeseaaplicarunajusteporcentualestacional .Setratadeunafuncinmuyinteresantequefavoreceelusointeligentedelagua .

    Activar/Desactivar VM/Bomba por estacin PermiteactivarlaVlvulamaestra/Bombaporestacionesindividuales .

    Retardo en la secuencia de estaciones Proporcionaunretardoajustableentreestacionesdurantelasecuenciadeactivacinparaajustarsealasnecesidadesdevlvulasdecierrelentooperodosderecuperacindepozos .

    Control de VM/Bomba durante el retardo de estacinPermiteactivarodesactivarlaVlvulamaestra/BombaduranteelperiododeRetardoestacin .Rain Dial-R le permite elegir!

    Proteccin integrada de circuitosAyudaaprotegerloscomponenteselctricosdelcontroladorcontradaoscausadosporsobrecargaselctricasorayos .

    Interruptor automtico Permitequeelprogramadordetecteypaseporaltocualquierestacinquetengauncortocircuitoounsolenoideaveriado .Muestra"FUS"yelnmerodelaestacinafectadaparafacilitarlaidentificacinysolucindelproblema .

    Borrar memoria de programa Permiteborrarlamemoriadeunprogramaindividualsinafectaraotrosprogramas .

    Restaurar los valores de fbrica Permiterecuperarfcilmentelosparmetrosdeoperacinoriginalesdelafbrica,siesnecesario .

    3

  • F Cmo empezar

    Instalacin de la pila y programacin desde casa

    Lainstalacindelapilade9V(asuministrarporelusuario)tienedosfuncionesimportantes:primero,permitecompletarlaprogramacindeRainDial-Rantesdesuinstalacin,ysegundo,mantieneelmdulodecontrolsincronizadoconlafechayhoraactualesduranteposiblescortesdeenergaelctricademsde24horasdeduracin .Nota: La pila no es capaz de activar las vlvulas de los aspersores. Es necesario conectar el controlador al suministro elctrico de corriente alterna para que pueda activar las vlvulas.Elmdulodecontrolestdiseadoparapoderserextradofcilmente,pudindoseprogramarcompletamenteenunlugarmscmodo,porejemplo,ensusillnfavorito .Pararetirarelmdulodecontrol,simplementedesenchufeelconectordelcableplanodelatarjetadelcircuitoimpreso,luegosepareelmdulocuidadosamentedelasbisagrasapresin .RainDial-Rincorporaunamemorianovoltil,quemantieneintactalainformacindelaprogramacin,inclusosilapilaseagotaoesdesconectada .

    Instalacin de la pila1 . Abralapuertadelcontrolador .2 . Abraelmdulodecontrolsujetndoloporelbordederecho(enelmodelo

    paraexteriores,presionelapestaadeliberacindelmdulo) .3 . Retirelatapadelcompartimientodelapilapresionandohaciaabajoy

    haciafueraenelbordesuperiordelamisma .VerlaFigura 1 .4 . Enchufeelconectorenunapilaalcalinade9V .5 . Coloquelapilaenelcompartimientoyvuelvaacolocarlatapa .6 . Lapantallaempezaraparpadearconelmensaje12:00 AM(pulse

    cualquierteclaparadetenerla) . Nota: Para empezar a configurar un Programa de riego, consulte

    "Procedimientos de programacin bsicos" en la pgina 22.

    CUIDADO: Para evitar los peligros que pueden suponer la instalacin de pilas del tipo incorrecto, cambie la pila siempre por otra del mismo tipo o de un tipo equivalente . Elimine las pilas usadas correctamente, siguiendo las recomendaciones del fabricante de las mismas .

    4

  • EARTHGROUND

    MV/PUMP

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    5

    Figura 1

    Pila alcalina de 9 voltios (no incluida)

    Tapa del compar-timiento de la pila

  • Descripcin general: Interfaz del mdulo de control

    1 - Interruptor de Programa Uninterruptordeslizantedetresposicionesqueseutilizapara

    seleccionarelprogramaA,BoCparasuconfiguracin,repasodeprogramasuoperacinmanual .

    2 - Pantalla LCD ElpanelLCDdealtocontrastemuestratodalainformacinsobrelos

    programasysobreelfuncionamientodelcontrolador .

    3 - Teclas +/- Estasteclasseutilizanparaaumentaroreducirlosvaloresmostrados

    enlapantalladurantelaconfiguracin,laprogramacinylasoperacionesmanuales .Losvaloresseajustandeunoenuno(pulsarysoltar)oenmododeavancerpido(pulsarymantenerpulsado) .

    4 - Dial Uninterruptorrotativocon25posiciones,utilizadoparaseleccionar

    estaciones,horasdearranque,dasderiegoyfuncionesespecialesdurantelaconfiguracin,laprogramacinylasoperacionesmanuales .

    5 - Tecla Manual Seutilizaparainiciarycontrolarlaactivacinmanualdelas

    estaciones .Tambinsirvecomotecladeavancedurantediversasoperacionesdeconfiguracin,programacinymanuales .

    6 - Interruptor de funcin Uninterruptordeslizantedetresposicionesutilizadoparaseleccionar

    entrelostresmodosdefuncionamientodelcontrolador: Off or Stop Detienetodaslasoperacionesderiegoactualmenteen

    marcha,eimpidetodaoperacinautomticaomanual . Set Programs Permiteseleccionarymodificarlosvaloresde

    configuracindelosprogramasderiego . Run or Manual Laposicinnormaldelinterruptorparatodaslas

    operacionesderiegoautomticasymanuales .

    7 - Tecla de arranque semiautomtico Seutilizaparaarrancarmanualmenteunprogramaderiego

    automtico .SeutilizatambinparainiciarlaPruebadefuncionamientodeestaciones .

    6

  • 7

    Figura 2

    1

    2

    3

    4

    5

    6

    7

  • Descripcin general: Componentes internos del controlador

    1 - Compartimiento de la pila Latapaapresinofreceunaccesofcilalapilaalcalinade9V .

    2 - Cable plano del mdulo de control Permitedesconectarrpidamenteelmdulodecontroldelarmariopara

    facilitarlaprogramacindesdecasaoelmantenimiento .

    3 - Terminal de puesta a tierra Terminalparalaconexindeuncabledetierra .

    4 - Interruptor de anulacin del sensor Interruptorquecontrolalaentradadelsensor(opcional)delluvia/heladas . 5 - Fusible de seguridad Unfusibledefundidolentode2Aqueprotegeelcontroladorcontra

    sobrecargasporcortocircuitoenelsuministroelctricode24VCA .

    6 - Terminales de conexin del transformador de corriente (24 VCA) Terminalesdeconexinparaloscablesdeltransformadorde24VCA,ypunto

    deconexinparalaalimentacindelcontrolremotoopcionalCMR-KIT . 7 - Terminal comn de las vlvulas (VC) Terminalparalaconexindelcablecomn(campo)delasvlvulas .

    8 - Terminales del sensor de lluvia (Sensor) TerminalesparalaconexindeloscablesdelRainSensorTMmodelos

    RS500,RS1000,oRFS1000deIrritrol(opcionales) .

    9 - Puente de los terminales del sensor PuentedelosterminalesdelsensorSeretiranicamenteparaconectar

    unsensordelluviaodelluvia/heladas)

    10 - Terminal de vlvula maestra/bomba (MV/PUMP) TerminalparalaconexindeloscablesdelaVlvulamaestraoRelde

    arranquedebomba(opcional) .(ElpuentedelosterminalesdelsensorseretiranicamenteparaefectuarlaconexindelRainSensor .)

    11 - Terminales de vlvulas TerminalesparalaconexindelasvlvulasUnterminalparacada

    vlvula .(LadisposicindelosterminalesvarasegnelmodeloElmodeloilustradoeselde12estaciones .)

    12 - Conector para el control remoto de mano Controldeconexinmodularparaelsistemadecontrolremotodemano

    modelosCMR-KIToKSR-KIT-KdeIrritrol .

    8

  • 9

    1 2 3 4

    5

    6

    7

    8

    9

    1011

    Figura 3

    12

  • F Procedimientos de instalacin

    wInstalacin del armario del ControladorSeleccioneunlugarprotegidoparalainstalacindelmodeloparainterioresdelRainDial-R,comoporejemploungarajeocuartodemquinas,preferentementeamenosde5'(1,5m)deunatomadecorrienteelctricacontomadetierra .Paramodelosdeexteriores,seleccioneunlugarquelosprotejacontralaexposicindirectaalaluzsolaryelcontactoconelaguaderiegopulverizada,queestaunadistanciamnimade5'(1,5m)decualquierequipoconmotor .1 . Atornilleeltornillodeaceroinoxidablesuministradoenunmontantedepareda

    unaalturacmoda,dejandoexpuestoaproximadamente1/4"(6,4mm)deltornillo . Nota: Utilice anclajes de tornillo para la instalacin sobre paredes de cartn-yeso

    o de obra. 2 . Cuelgueelprogramadoreneltornillousandolaranuraenformadebocallave .3 . Sujeteelprogramadorconunoodostornilloscolocadosenlostaladrosde

    montajeinferiores . Nota: Los taladros de montaje inferiores del armario para exteriores estn

    obturados por una lmina fina de plstico que se penetra fcilmente al instalar el tornillo de montaje.

    wConexin del cableado de control de las vlvulasParaobtenerlosmejoresresultados,utilicecabledeconexindiseadoespecficamenteparasistemasderiegoautomtico .Utilicecablede18AWGparadistanciasdehasta800'delcontrolador,ocablemsgruesode14AWG(2,0mm2)

    paradistanciasdehasta2000' .Serequiereuncableindividualparacadavlvula(yrel)yalmenosuncablecomn(retorno) .Nota: Si es necesario instalar conductos para el cableado, instlelos ahora. Para la instalacin de conductos, utilice el taladro de acceso de 3/4" (19 mm) del armario para interiores, o el orificio roscado de 1,25 "NPT del armario para exteriores. 1 . Tiendaelcabledecontroldesdeelcontroladorhastalasvlvulas .2 . Conecteuncabledecontrolindividualacualquieradeloscablesdelsolenoidede

    cadavlvula .3 . Conecteelotrocabledelsolenoidedecadavlvulaauncableindividualpara

    formaruncablecomn(deretorno) . Nota: Para evitar la corrosin y posibles cortocircuitos, utilice conectores de cable

    impermeables en todos los empalmes exteriores. Anote el color del hilo utilizado para cada vlvula as como su zona de riego

    correspondiente para su referencia al hacer las conexiones en el controlador.10

  • 4 . Paseelcablealinteriordelprogramadoratravsdelaaberturamayordelabasedelarmariodelcontroladoroatravsdelconducto,siseinstal .Retirelacubiertadelcableparadejarexpuestoaproximadamente8"deloshilos .Retirecuidadosamente3/8"deaislamientodelextremodecadahiloquesevaaconectar .

    5 . Conecteelcabledecadavlvulaalterminalnumeradoenelordensecuencialpreferidoparasuoperacin .

    6 . ConecteelcablecomnalterminalmarcadoVC .7 . Ensucaso,conecteunhilodelcabledecontroldelavlvulamaestraodelrelde

    arranquedebombaalterminalmarcado"MV/PUMP",yelotrohiloalcablecomndelasvlvulas .

    Nota: El controlador no suministra la potencia necesaria para activar una bomba. El rel de arranque de la bomba debe tener una tensin de bobina nominal de 24 VCA, con una potencia mxima de 0,375 A.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    11

    Figura 4

    Vlvulas de control de los aspersores

    Hilo comn

    Rel de arranque de bomba o vlvula maestra

    1

    2

    3

    MV

    Rel 24 V

    Terminal de vlvula maestra/bomba

    Terminal comn de las vlvulas

  • Conexin de un sensor de lluvia (opcional) ElRainDial-RestdiseadoparafuncionarconjuntamenteconelRainSensormodelosRS500,RS1000oelsensordelluvia/heladaRFS1000deIrritrolpararestringirelriegocuandosecumplendeterminadoslmitesdehumedady/otemperatura .Nota: Si va a conectar otra marca de sensor de lluvia, asegrese de que sea compatible con un circuito de interruptor normalmente cerrado.

    IMPORTANTE: Si no se instala un sensor de lluvia, deje conectado el cable puente en los terminales del sensor y el interruptor Sensor en la posicin "Bypass . Si no se cumple alguna de estas dos condiciones, la operacin automtica y manual estar desactivada . 1 . Introduzcaelcabledelsensorporlaparteinferiordelarmario .

    2 . Aflojelosterminalesdelsensoryretireelcablepuente .

    3 . Consultelasinstruccionesdeinstalacinsuministradasconelsensordelluvia,yconecteloscablessegnlasinstrucciones .

    4 . PongaelinterruptorSensorenlaposicinActive . Nota: Cuando el sensor de lluvia est activado, se

    suspenden todas las operaciones de riego y se muestra SEn (Sensor) (en la posicin Current Time del Dial).

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    12

    Figura 5

    Sin cable puente

  • Conexin de una unidad de control remoto (opcional)ElcontroladorRainDial-RestpreparadoparaelcontrolremotoyestotalmentecompatibleconambosmodelosdecontrolremotodemanoIrritrol:elmodeloresidencialdecortoalcanceKSR-KIT-K,yelmodelocomercialdelargoalcanceCMR-1-KIT .Ambossistemasdemanoofrecenfuncionessimilaresdecontrolremoto .Laguadelusuariosuministradaconcadacontrolremotocontieneinformacincompleta .

    Segnsemuestraenlailustracinsiguiente,laclavijadelreceptorKSR-KIT-KseenchufasimplementeenelconectordelapartetraseradelmdulodecontroldelRainDial-R .ElreceptordelCMR-1-KITtambindebeconectarsealosterminalesde24VCA .

    Nota: Los receptores/clavijas de ambos modelos de control remoto son parecidos, pero no son intercambiables.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    13

    Figura 6

    Conector CMR-CC del control remoto CMR-1-KIT

    Conector CA-03 del control remoto KSR-KIT .

  • Conexin a una toma de tierraNota: Para que los componentes de proteccin contra sobrecargas de su Rain Dial-R funcionen correctamente, el controlador debe conectarse a un dispositivo de tierra, como por ejemplo una pica de tierra revestida de cobre o una tubera de agua metlica, usando cable de cobre macizo. Esta conexin es especialmente importante cuando se instala el controlador en una zona propensa a rayos .

    1 . Conecteuncabledecobremacizode1216AWG(2mm21,3mm2)aldispositivodetierrayllveloalcontroladoratravsdelaaberturadelabasedelarmario .

    2 . ConecteelcabledetierraalterminalmarcadoEarthGround .

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    Tubera de agua metlica

    Pica de tierra de 2,4 m revestida de cobre (en suelo hm-edo)

    14

    Figura 7

  • Conexin del suministro elctrico Modelos para interiores 1 . Introduzcaelcabledeltransformadorexternoatravsdeltaladropequeo

    provistoenlaparteinferiordelarmario .

    2 . Hagaunnudoenelcableparaprotegerlocontratirones,yconecteloscablesalosterminalesmarcados"24VCA"(encualquierorden) .

    3 . Cierreelmdulodecontrolyenchufeeltransformadorenunatomadecorriente .Elcontroladorestpreparadoparasuprogramacnyuso .

    Nota: Para hacer una prueba inmediata del sistema de control de riego Rain Dial-R, consulte "Prueba de funcionamiento de estaciones" en la pgina 17.

    EARTHGROUND

    MV/Pump Sensor

    + -

    7 8 9 10 11 12

    1 2 3 4 5 6

    24 VACVC

    Figura 8

    15

    Nudo de segu-ridad

    Nudo de seguridad

    Transformador de 24 VCA, 30VA

  • Conexin del suministro elctrico Modelos para exteriores

    ADVERTENCIA: Todos los componentes elctricos y mtodos de conexin deben cumplir la normativa nacional y local aplicable sobre instalaciones elctricas, incluyendo la instalacin por personal cualificado . Estas normas pueden exigir la instalacin de una caja de empalmes en el conector NPT de 1/2" (13 mm) del controlador y algn medio de desconectar el suministro elctrico CA en el cableado fijo, con una separacin entre contactos de al menos 0,120" (3 mm) en los polos de fase y neutro . El cable de conexin debe contar con aislamiento resistente a 105 C como mnimo .

    El controlador debe conectarse a una toma de corriente con tierra . No lo conecte a una fase de un suministro elctrico trifsico usado por una bomba u otro equipo elctrico .Antes de conectar los cables del controlador, compruebe que la electricidad ha sido desconectada en la toma de corriente, usando un voltmetro de corriente alterna .1 . Conecteunregistrodeconductode1/2"(13mm)NPTalconectorroscado

    deltransformador .Desdeelregistrodeconducto,instaleelconductoelctricohastalatomadecorrienteelctricaCA(deacuerdoconlanormativasobreinstalacioneselctricas) .

    2 . Pasecablede14AWGatravsdelconductohastaelregistro .3 . Usandoconectoresdecable,conecteloscablessegnsemuestraenla

    Figura 10 .4 . Cierreyafianceelregistrodelconducto .5 . Enciendaelsuministroelctricodelcontroladorycompruebeelfuncionamiento

    delcontrolador .Sielcontroladornofunciona,desconecteelsuministroelctricoensuorigenyhagaqueuninstaladorelctricocualificadocompruebesihayalgnposiblecortocircuito .

    CUIDADO: Para asegurar la mxima proteccin de los componentes electrnicos del controlador cuando est instalado en el exterior, mantenga siempre cerrada la cubierta del armario, con llave siempre que sea posible . Guarde las llaves del armario en un lugar seguro y de fcil acceso .

    16

    Figura 9

    Llave

  • Prueba de estaciones

    LafuncinPrueba de estacionesdelcontroladorlepermitecomprobarrpidamenteelfuncionamientocorrectodelasvlvulasdespusdelainstalacininicialodecualquiermantenimiento .Elciclodepruebaactivatodaslasvlvulassecuencialmenteduranteuntiempoderiegoprovisional,ajustablede1-10minutos .

    1 . PongaelinterruptordeFuncinenlaposicinSet ProgramsoRun .2 . GireelDialalaposicinSkip DaysSpecial Functions .3 . PulselateclaManualunavezparaseleccionarla

    pantalladepruebadeladerecha .

    4 . Pordefecto,eltiempodefuncionamientodelapruebaesde2minutos .Paraajustareltiempoderiegoentre1y10minutos,pulselatecla o .

    5 . PulselateclaSemi-Autoparaarrancarelcicloderiego .SeactivarlaEstacin1 .

    6 . GireelDialalaposicinCurrent Time .Lapantallaindicarlahoraactualdelreloj(inicialmentelas12:00PM)ylaestacin1 .

    7 . Paraavanzarmanualmenteporlasecuenciadeestaciones,pulselateclaManual .

    RD-1200

    A-+

    B-C-

    MANUAL

    TodaySun

    Mon

    Wed

    Thu

    2

    3

    4

    5

    6

    7

    8

    9

    1011123

    21

    PM

    SC

    HE

    DU

    LE

    STARTTIMES

    VA

    LV

    ER

    UN

    TIM

    ES

    17

    Figura 10

    1 2 3 4 5 6 7 8 9 10 11 12

    Tierra a Verde o Verde/Amarillo

    Fase o L2 a Negro o Marrn

    Neutro o L1 a Blanco o Azul

    Registro de conducto

    Conducto elctrico

  • F Cmo obtener los mejores resultados de su controlador Rain Dial-R Qu es un ciclo automtico de riego programado? Unprogramaderiegoautomticoempiezaalaprimerahoradearranqueasignadaenundaderiegoprogramado .LavlvulaconelnmeromsbajoasignadaalProgramaseactivayhacefuncionarlosaspersoresduranteeltiempoderiegoespecificado .Cuandotermine,lasiguientevlvulaenordennumrico(quetengauntiempoderiegoasignadoenelprograma)empiezaafuncionar .ElcicloderiegoprogramadocontinahastaquesehayanactivadotodaslasvlvulasquetenganasignadountiempoderiegoenelPrograma . Por qu tres programas? Unpaisajeresidencialtpicoincluyediferentesseccionesdecsped,arbustos,rbolesyvegetacindesuelo,todaslascualesnecesitanregarseusandoprogramasdiferentesparamantenerlasaluddelasplantasyunaconservacinptima .Paralograresto,elRainDial-Rofrecetresprogramasderiegoindependientes:A,ByC .Elejemplosiguientemuestracmopuedenutilizarsemltiplesprogramasparaobteneresteresultadoconfacilidad: Programa Hora de inicio Vlvula N Ubicacin Tiempo de riego Calendario

    A (N1)5:00AM 1 Cspeddelantero15min. Impar 2 Jardntrasero 15min. Impar 3 Jardnlateral 10min. Impar B (N1)3:00PM 4 rboles(goteo) 2h Lun C (N1)4:00AM 5 Jardn 5min. SaltarDas,1 (N2)7:30PM 5 Jardn 5min. SaltarDas,1

    18

  • Evite horas de arranque inesperadas Esposibleprogramarunasegundahoradearranquequeempieceantesdequesehayaacabadoelciclodelaprimerahoradearranque .Siestoocurre,sedemoraelarranquedelsegundociclohastaquesehayacompletadoelprimero,demaneraquelahoradearranquepuedenocoincidirconlahoraesperada .Adems,unaumentodeltiempoderiegodebidoalafuncindeajusteporcentualpuedecausarunsolapamientoqueretrasalasiguientehoradearranqueprogramada .

    Evite regar en un da no de riego Uncicloderiegoquecontinamsalldelamedianochesecompletarsintenerencuentasieldasiguienteesundaderiegoprogramado .

    Evite regar en exceso Pordefecto,losprogramasA,B,yCpuedenprogramarseparaestaractivadosdeformaconcurrente(solapamiento) .EstecomportamientopuederestringirseseleccionandolaopcinApilamientodeprogramas(verpgina28) .Sihayhorasdearranqueintroducidasencualquierprograma,seiniciarnciclosderiegoautomticamenteaesashoras .Elusodemltiplesprogramaspermitequelasdiferentesestacionesdevlvulasrieguenconcalendariosdiferentes,opermiteaplicarunriegosuplementariosinobastaunsoloprograma .Sinecesitariegoadicional,utilicemsdeunahoradearranqueoutilicelafuncindeAjusteporcentualparaaumentareltiempoderiegodeunaestacindeterminada .

    Evite crear una condicin de baja presin del agua Lashorasdearranqueasignadasadiferentesprogramassonindependientesentres .Siustedestablecehorasdearranqueidnticasosolapadas,puedeactivarsemsdeunavlvulaalmismotiempo .Elcaudaltotalpuedesuperarelsuministrodeaguadisponible .Paraevitarestasituacin,dejemstiempoentrehorasdearranqueparareducirelnmerodevlvulasenfuncionamientoencadamomento,yasegresedenoasignarlamismahoradearranqueamltiplesprogramas .

    Arraigamiento de csped nuevo Esespecialmentetilestablecermltiplesciclosderiegocortoscadadaduranteelarraigamientodeuncspednuevo .

    Ayuda con problemas elctricos ElRainDial-RmuestraelNmerodeestacinylapalabraFUSsisedetectauncortocircuitoenunavlvula .Sesaltarlaestacinencuestin,permitiendolaactivacindelasdemsestacionesdelcicloderiegoprogramado .

    19

  • F Indicaciones en pantalla

    Lossiguientesejemplosmuestranlainformacinproporcionadaenpantallaparaayudarleenlosdiferentesmodosdeprogramacin,configuracinyoperacin .

    Modo Programacin (Funcin Set Programs)

    Current Time(Horaactual)muestralahoraactual .

    Valve Run Times(Tiemposderiegodelasvlvulas)muestraeltiempoderiegodelnmerodevlvulaseleccionado .Indica0159minutos,1,05,9horasuOff(desactivada) .

    Start times(Horasdearranque)muestralashorasdearranqueasignadasalprogramaseleccionado .

    Today(Hoy)muestraelDaActualdeuncalendarioDas de la semana,porejemploSu,Mo,(domingo,lunes)etc .,oeldaprogramadodeuncalendarioSaltar das(131) .

    ScheduleMuestraONuOFFparacadadadeuncalendarioDas de la semana .CuandoseutilizauncalendarioPar/Impar,semuestraOdd(Impar),Even(Par)uOFF(Desactivado)paracadaestacin .CuandoseutilizauncalendarioSaltar das,semuestraOnce every (0131)(Unavezcada01-31) .

    Funciones especiales (Dial Special Functions)

    Ciclo de prueba de estacionessemuestranlosnmerosdetodaslasestacionesactivasenlapartesuperiordelapantalla .T:0110indicaenminutoseltiempoderiegoseleccionadoparaelciclodepruebas .

    Ajuste porcentual (por programa)muestraelAjusteporcentualactual,uOFF(Desactivado) .SiseestutilizandounAjusteporcentualmensual,semuestra( ) .

    Borrar memoria de programaCLrindicaqueestseleccionadalafuncinClearMemory(Borrarmemoria) .

    Tiempo de recuperacin de pozoindicalademora(0059segundos,159minutoso1-2horas)entreestacionesenuncicloderiego .

    20

    1 2 3 4 5 6 7 8 9 10 11 12

  • Activacin de bomba durante Retardo estacin indicasilaactivacindelabombaestenOn(activada)uOff(desactivada)duranteelperiododeretardoentreestaciones .

    Apilamiento/solapamiento de programasIndicasiestseleccionadoApilamiento(1:On)oSolapamiento(3:On) deprogramas .

    Calendario Par/Impar IndicasiestseleccionadoelcalendarioOdd(impar)oEvn(par) .

    Mes Muestraelmesactual .

    Mes/da Muestraelmesyeldaactuales .

    Ao Muestraelaoactual .

    Suspensin temporal por lluviaIndicaelnmerodedas(09)desuspensindelaoperacinautomtica .

    Ajuste porcentual mensual Indicaelestadodeajusteporcentual(On/Off)pormes(112)yelporcentaje(01200uOff)asignadoacadames .(Tambinpuedenajustarseahoraelmes,dayao .)

    Modo de funcionamiento (Funcin Run) Modo automtico (Dial Hora Actual)Muestraelnmerode

    lavlvulaactivaylahoraactual .(Dial Nmero de la vlvula activa)nmerodelavlvulaactiva,programaactualytiempoderiegorestante .

    Nota: Si est activado Ajuste porcentual, se muestra el tiempo de riego ajustado.

    Modo manual (Dial Nmero de vlvula activa)-semuestraelnmerodevlvula,M:yeltiempoderiegorestante .

    Suspensin temporal por lluvia semuestraOF(desactivado)yelnmerodedasrestanteshastaquesereanudeelriego,alternandoconlahoraactual .

    Interruptor automtico semuestra"FUS"yelnmerodelaestacinafectada,alternandoconlahoraactual .

    21

  • F Procedimientos bsicos de programacin

    Ajuste de la fecha y la hora actuales

    1 . PongaelinterruptordeFuncinenlaposicinSet Programs(centro) .

    2 . GireelDialalaposicinCurrent Time .

    3 . Pulselatecla o paraestablecerlahoraactual(Nota:AM/PM) .

    Nota: Al usar la tecla o , pulse y suelte la tecla para ajustar el valor en pasos, o pulse y mantenga pulsada la tecla para desplazarse rpidamente.

    4 . GireelDialalaposicinToday .

    5 . Pulselatecla o paraseleccionareldaactual(abreviatura) .

    Nota: Si se utiliza un calendario de das Pares/Impares o Ajuste porcentual mensual, el da actual de la semana est preestablecido y no puede modificarse.

    6 . GireelDialalaposicinCurrent Time .

    7 . PongaelinterruptordeFuncinenlaposicinRun .

    Nota: El signo de dos puntos (:) parpadeante indica la presencia de corriente alterna. Si el signo no parpadea, el controlador est funcionando con la pila solamente.

    Ajuste del tiempo de riego de las vlvulas

    Cadaestacinpuedetenerasignadountiempoderiegoindividualencadaprograma .Eltiempoderiegopuedeajustarsede159minutos(enincrementosde1minuto),ode15,9horas(enincrementosde1/10dehora) .

    1 . PongaelinterruptordeFuncinenlaposicinSet Programs(centro) .

    2 . SeleccioneelProgramaA,BoC .

    3 . GireelDialparaseleccionarelnmerodelavlvulaaajustar .

    4 . Pulselatecla o paraestablecerlahoradeiniciodeltiempoderiegodelavlvula .

    5 . Repitalospasos3y4paratodaslasvlvulasquevayanaasignarsealprogramaseleccionado .

    6 . Repitalospasos2-5paracadaprograma,segnseanecesario .

    7 . Cuandotermine,gireelDialalaposicinCurrent Time(Horaactual) .

    8 . PongaelinterruptordeFuncinenlaposicinRun .22

  • Ajuste de las horas de arranque de los programas

    Cadaprogramapuedetenertreshorasdearranqueindependientes .Parapaisajesmaduros,unasolahoradearranqueporprogramasuelesersuficiente .Sielcspedesnuevo,elusodedosotreshorasdearranquecontiemposderiegocortospuedeproporcionarelriegoadicionalnecesarioparaelarraigamiento,concaudalesmenoresparaayudaraevitarescorrentasyerosin .1 . PongaelinterruptordeFuncinenlaposicinSet Programs .2 . SeleccioneelProgramaA,BoC .3 . GireelDialaStart Time1,2o3(Horadearranque1,2,3) .4 . Pulselatecla o paraestablecerlahoradearranque(Nota:AM/PM) . Nota: Para eliminar un tiempo de inicio, seleccione Off, situado entre

    11.5912.00 y 5.59 6.00 (AM y PM).5 . Repitalospasos3y4paraajustarmshorasdearranqueparaestePrograma .6 . Repitalospasos2-5paracadaprograma,segnseanecesario .7 . Cuandotermine,gireelDialalaposicinCurrent Time(Horaactual) .8 . PongaelinterruptordeFuncinenlaposicinRun .

    Ajuste del calendario de das de riego

    PuedenprogramarsedasderiegoparacadaPrograma,usandounodelosmtodossiguientes: Das de la semanaProgramaelriegoendasespecficosdelasemana . Saltar dasProgramalosdasderiegoporintervalos,porejemplocadada

    (01),dasalternos(02),etc . Da Par/ImparProgramalosdasderiegoenlosdasParesoImpares .Para