Page 1: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 1 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

USER MANUAL for SANHUA QuickFinder

Page 2: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 2 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

CONTENTS

1 INSTALLATION 3

2 LANGUAGES 4

3 LOAD FLUID THERMODYNAMIC AND TRANSPORT PROPERTIES DATABASE 5

3 PRODUCT TYPE SELECTION WINDOW 7

4.1 Input the condition parameters 8

4.2 Select the position of the valve. 9

4.3 The selection for CBVT 10

5 Export the product selection list. 10

5 OTHER FUNCTION 12

Puspose of the Sanhua QuickFinder software is to make calcualtions of Sanhua products according various User conditions, however Sanhua declines any responsibility for the wrong product selection made by customer with this tool. For proper selection of final component User is responsible to take into consideration and respect

- Local legislation/certification requirenments and availability of necessary certificates for desired products

- Product application limits according to Sanhua official documentation (Datasheets, Installation Instructions, Drawings, etc)

Page 3: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 3 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

1 INSTALLATION Double click on the QuickFinder.exe. Immediately on the screen will appear the following initial window (Fig.1). In the Initial Window, you can choose the language, then click on the arrow to proceed to the next window until the software is installed completely. If you need to change the software installation path, please click the “Change” button in the installation window2.

Fig.1 – Initial Window

Page 4: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 4 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.2- installation window2

2 Languages Click on the “Languages” button present in the menu bar will appear a drop-down menu where it is possible to change the language used in the present moment by the software, as shown in Figure 3. Now there are two languages: English and Chinese.

Page 5: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 5 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.3- Languages

3 Fluid Thermodynamic and Transport Properties Database The QuickFinder requires Refprop, a fluid thermodynamics and transmission properties database developed by NIST. After uploading Refprop (Fluid Thermodynamic and Transport Properties) Database following figure 4, click the “Refprop.dll Path” in the options menu bar, and then find the installation folder of refprop in the pop-up dialog box, and select the file refprp64.dll (if you use the 32-bit operating system, please select the other file Refprop.dll), as shown in Fig.5.

Page 6: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 6 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.4- Click the“Refprop.dll Path”

Fig.5- Load Refprop.dll

Page 7: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 7 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

3 PRODUCT TYPE SELECTION WINDOW This software provides a simple and efficient way to select the proper sanhua products for your application. The following product categories are included in the list: a) Solenoid Valves b) Thermostatic Expansion Valves c) Electronic Expansion Valves d) Four Ways Reversing Valves e) Ball Valves f) Check Valves g) Sight Glasses h) Filter Dryer i) Service Valve The “Product List Window” (Fig.6) presents on a series of product pictures. Click on the product picture can login to the product series details window(Fig.7), and click on the picture button that represents the requested family of products, and can login the Product Selection Window(Fig.8).

Fig.6 – Product List Window

Page 8: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 8 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.7- Product Series Details Window

Fig.8- Product Selection Window

4.1 Input the condition parameters

In the Condition Frame(Fig.9), we input the basic condition information, as follow: a. Refrigerant Type b. Requested Cooling Capacity c. Evaporating Temperature

Page 9: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 9 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

d. Condensing Temperature e. Super-Heating f. Sub-Cooling g. Pressure Drop (ΔP): Described the Pressure drop (in bar) under the set

conditions. if the exhaust temperature cann’t be checked this tool will predicts the exhaust temperature based on the input parameters, and the relevant parameters are calculated according to the exhaust temperature.

Fig.9- Conditions

4.2 Select the position of the valve.

Click on the Pos.A, Pos.C or Pos.D to select the position of the valve as (Fig.10). and then click on the Search button, we can get the valve model in the table1(Fig.11). And Choose a connection in the table2(Fig.12), choose the coil by the table3(Fig.13).

1.

Fig.10 Select the position

Fig.11 Table1: Select the valve model

Fig.12 Table2: Valve body information sheet

Page 10: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 10 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.13 Table3: Coil information sheet

4.3 The selection for CBVT

For CBVT series ball valve, when the input condition is supercritical condition, the condenser pressure Pk is also a necessary parameter to select the product, besides the condenser temperature! At this time, the condensing temperature Tk is the outlet temperature of the condenser, where the condensing pressure Pk is the high pressure !

Fig14. Input the high pressure Pk

5 Export the product selection list. Clicking on the “File”-“Export PDF” You can login the export file settings window(Fig.12). Input the parameters and click on the save button, then determine the export path of the file and save the name, as follow Fig.15.

Page 11: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 11 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig.15 the export file settings

Page 12: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 12 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

Fig16. the export file

5 Other function In the Option menu bar, you can set the custom units, such as American units, International common units, and you can reset the units according to habits.

Fig17. Custom units set

Page 13: USER MANUAL for SANHUA QuickFinder

QuickFinder

Copyright © SANHUA 2019 13 UM-SELECTION SOFTWARE-EN-R1907 Subject to change without notice

The meaning of the position in the software is shown in Fig.18,

ID Pipe position State 0 Evaporator outlet saturated vapor

1 Evaporator outlet(pipe) superheat vapor

2 Compressor suction superheat vapor

3 Compressor outlet superheat vapor

4 Condenser inlet (pipe) superheat vapor

5 Condenser inlet saturated vapor

6 Condenser outlet Saturated liquid

7 Expansion valve inlet Supercooled liquid 8 Expansion valve outlet vapor-liquid mixture

9 Evaporator inlet vapor-liquid mixture

Fig.18. the meaning of the position

Other condition settings as follow Fig.19, ➢ Invalid superheat The invalid superheat is equal to the difference between the temperature of compressor suction port (t2) and the temperature of valve inlet on the evaporator outlet pipe (t1),that is t2-t1. The default setting is 0, It can also be resetted based on the actual condition. ➢ The temperature difference between condenser inlet and compressor exhaust The temperature drop at condenser inlet is equal to the difference between the temperature of condenser inlet (T4) and the temperature of compressor exhaust (T3), that is t3-t4, which is 0 by default. The setting can also be modified according to the actual condition. ➢ Buffer coefficient for pressure drop across valve This coefficient is used to relax the "allowable pressure drop limit" and increase the optional range of the product, which is 20% by default. The change of this value will not affect the recommended results, thermal expansion valve and electronic expansion valve.