tteemmppeerraattuurre e ccaalliibbrraattoor r · ¦ nabl accredited temperature calibration ¦...

34
¦ Liquid Bath ¦ Dry Block Calibrator ¦ Black Body Source ¦ Reference Junction Box ¦ Cold Junction Probes ¦ Lab Automation ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration Temperature Calibrator Temperature Calibrator Temperature Calibrator www.tempsens.com

Upload: others

Post on 20-Apr-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

¦ Liquid Bath

¦ Dry Block Calibrator

¦ Black Body Source

¦ Reference Junction Box

¦ Cold Junction Probes

¦ Lab Automation

¦ NABL Accredited Temperature Calibration

¦ Onsite Temperature Calibration

Temperature Calibrator Temperature Calibrator Temperature Calibrator

w w w . t e m p s e n s . c o m

Page 2: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

The comparison of a measuring instrument against an

accurate standard to determine any deviation.

The device with known assigned correctness is called the

Standard. The second device is the Unit Under Test (UUT).

In case of accurate thermocouple measurement, it’s a

common practice to reference the cold junction

temperature at ice point (0°C) so that copper leads may be

connected to an EMF readout

device. This procedure avoids the

compensation of cold junction

temperature at the terminal of

read out which may not be

constant and the measurement

may not be very accurate.

What is Calibration

Accurate Temperature Calibration

Temperature Calibration has many facets. It can be carried

out thermally in the case of probes or electrically in the

case of Instrument and it can be performed directly with

certified equipment, or indirectly with traceable

standards.

Thermal (Temperature) calibration is achieved by elevating

(or depressing) the temperature sensor to a known,

controlled temperature and measuring the corresponding

change in its associated electrical parameter (voltage or

resistance).

The accurately measured parameters compared with that

of a certified reference probe; the absolute difference

represents the calibration error. If the sensor is connected

to a measuring instrument, the sensor and the instrument

combination can be effectively calibrated by this

technique.

A typical general purpose system comprises of a thermal

reference (stable temperature source), a certified

reference probe with its certificate, a precision electronic

digital thermometer, bridge or digital voltmeter.

Dry Block Calibrator

Provides the most convenient, portable facilities for

checking & calibrating industrial probes and they are

usually reasonable rapid heating and cooling device. The

unit consists of a special designed heating block which has

located internal holes for the probes. Although the block

temperature is accurately controlled, any indication

provided should be used for guidance only.

As with any comparison technique a

certified sensor and indicator should be

used to measure the block temperature

and used as a reference for the test

probe. Two types of unit are available;

portable units which can be taken on to

plant for the on-site calibration and

laboratory units to which industrial

sensors are brought as required.

Temperature Source

Black Body Source

Black bodies are reference sources used for testing

infrared systems. They are required in industry for

calibration of pyrometers, infrared line scanners or

cameras. In laboratory, they are

p a r t o f b e n c h e s f o r

characterization of complex

optronic systems. Tempsens offers

a wide range of black bodies to

cover all Customer’s needs.

Cold Junction Compensation

By connecting any thermocouple to measurement device

three dissimilar metal junction are created in the circuit:

the thermocouple junction itself, or hot junction, and the

junction between each lead and the measurement device,

or cold junctions. These cold junction provide their own

thermoelectric voltages that are proportional to the

temperature at the device terminals.

A technology known as cold junction compensation is

therefore used to remove this unwanted effect.

Referernce Unit

Stirred Liquid Bath

Provide superior thermal environment

for probe immersion as no air gap exist

between the probe and the medium

Thermal coupling is therefore much

better than the alternatives described,

and the stirring results in very even heat

distribution throughout the medium.

Methanol is used for temperature

below 0°C, water from 0 to 80°C and

silicon oil for upto 250°C.

Page 3: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Division of contact type calibrators according to the temperature range.

Stable Reference Unit

Reference temperature could be change according to customer requirementTo be specified at time of ordering

Master Sensor

SENSOR TYPE ORANGE( C) ACCURACY

PT 25.5

PT 100

PT 200

K/N Type

R/S Type

RTD

-80 to 400

-80 to 250

-80 to 250

-80 to 250

0 to 1200

0 to 1500Thermocouple

± 1.1°C OR ± 0.4%

± 0.6°C OR ± 0.1%

Class A

1/3 DIN

1/5 DIN

1/10 DIN

SSPRT _ upto 660 long term drift ≤ ±50mk/Yr.

Bath Dry Block

-200°C

0°C

200°C

400°C

600°C

800°C

1000°C

1200°C

1400°C

1600°C

1800°C

Cal

sys

-19

6/-

80

Cal

sys

-30

/11

0

Cal

sys

-15

/11

0

Cal

sys

65

0

Cal

sys

FB

Cal

sys

12

00

Cal

sys

12

00

L

Cal

sys

12

00

3Z

Cal

sys

15

00

L

Cal

sys

17

00

L

Cal

sys

-80

/50

Cal

sys

-40

/50 Cal

sys

-35

/20

0

Cal

sys

12

0SP C

alsy

s 3

00

SP

Cal

sys

25

0

Calibrators Temperature Representation for Contact Type Calibration

*

*

TYPE CALref 0 CALref 60

Channel 20

0°C

J,K,T,E,N,R,S,B J,K,T,E,N,R,S,B

24

60°CRef. temp.

Portable Model

Wall Mounted

Model

Type of Junction

**

Page 4: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Division of non-contact type calibrators according to the temperature range.

Stable Reference Unit

Reference temperature could be change according to customer requirementTo be specified at time of ordering

TYPE CALref 0 CALref 60

Channel 20

0°C

J,K,T,E,N,R,S,B J,K,T,E,N,R,S,B

24

60°CRef. temp.

Portable Model

Wall Mounted

Model

Type of Junction

Master Sensor

SENSOR TYPE ORANGE( C) ACCURACY

PT 25.5

PT 100

PT 200

K/N Type

R/S Type

RTD

-80 to 400

-80 to 250

-80 to 250

-80 to 250

0 to 1200

0 to 1500Thermocouple

± 1.1°C OR ± 0.4%

± 0.6 °C OR ± 0.1%

Class A

1/3 DIN

1/5 DIN

1/10 DIN

SSPRT _ upto 660 long term drift ≤ ±50mk/Yr.

Calibrators Temperature Representation for Non-Contact Type Calibration

-200°C

0°C

200°C

400°C

600°C

800°C

1000°C

1200°C

1400°C

1600°C

1800°C

2000°C

2200°C

2400°C

2600°C

2800°C

3000°CLB

B3

3H

Cal

sys

11

0 B

B

Cal

sys

50

0B

B

Cal

sys

12

00

BB

Cal

sys

15

00

BB Cal

sys

17

00

BB

Fast

cal 3

00

0

Black Body

*

*

*

*

Page 5: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURES

ü High Stability

ü PC Interfacing

ü Simple to use & Cost effective portability

TPW in Thermal CalibrationThermal Calibration lab has facility for Fixed point calibration of SPRTs, HTPRTs and standard thermocouples probe. Fixed point calibration are used for primary temperature standard in thermal calibration to achieve the lowest possible uncertainties. Triple point of water cell may be the most commonly used type of fixed point and it is used in ITS-90 calibration. Water can exist as a solid, liquid and vapor at 0.01 deg C.Tempsens TPW CellTempsens TPW cells are manufactured with high quality borosilicate glass in two sizes mini & Standard. Special procedure for cleaning, ultra pure water with special degassing technique is used and the cell is flame sealed.

Maintenance ApparatusTempsens made maintenance dry block is best fitted for tpw cells. They are carefuly designed to give the required stability and uniformity and provide sufficient immersion depth for TPW cell. It can be also use as dry block calibrator using equalizing block for comparison calibration.Equipments Used In Realization TPW Mini CellPlatinum Resistance Thermometer (PRT)Measuring EquipmentAccessoriesŸ Master RTD Model No. TPRT - A - 300Ÿ Carry case Ÿ Operational ManualŸ Insertion Block Dia 32mm x 180mm long with 4 x 6mm

hole of 150 mm insertion depth

Maintenance Apparatus For Tpw CellDRY BLOCK FURNACE : Dry block offers medium temperature range from -15°C to 110°C. It is a highly stable standard temperature source for cal ibrat ing RTD/thermocouples. It has peltier elements to generate stable temperature in the well. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Self tuned PID controller used for increased or decreased temperature.

Triple Point Of Water Cell with Maintenance Apparatus

Triple point of water is the most important defining thermometric fixed point used in the calibration of thermometers. Triple point of water cell is used to create a thermal equilibrium between solid, liquid and vapor phases are independent of ambient pressure. This thermal equilibrium occurs at 273.16 Kelvin or 0.01 degree Celsius. TPW cell is cylindrical borosilicate glass filled with pure water. The water in the cell is high purity and gas free and have isotropic composition.

Uncertainty 2mK

Reproducibility <1mK

Dimensions OD-32 mm,Total Length-165mm

Material Borosilicate Glass

Immersion Profile

Depth 150 mm

Insert Construction 1 hole of 8 mm dia

Water Used 99.999% Pure distilled water

TPW Cell Type Mini

SPECIFICATIONS OF CALSYS -15/110

Ÿ Temperature Range : -15/110Ÿ Temperature Resolution : 0.1°CŸ Controlling Sensor : RTDŸ Power Requirement : 230 VACŸ Weight : 14 kgŸ Stability : 0.05°C Ÿ Time to reach min. Temp. : 30Min.Ÿ Method of control : Digital self tuned PID

controller Ÿ Dimension : 430(H) x 170(W) x

188(D) mmŸ Insert Construction : 33mm Dia x 220mm

long for dry block

Page 6: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -190/-80 offers ultra low temperature range from -190 to -80°C. It is a highly stable standard source for calibrating Thermocouples / RTD. It has been designed for low temperature range calibration and find application in the glass, pharma, electrical power, automotive & material processing industries. The comparison volume is a metallic block of aluminium having dimension 25mm diameter with 300 mm long which fixed into the liquid nitrogen container for calibration of RTD & thermocouple. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment.

PORTABLE RTD CALIBRATOR

Temperature Range : -190 to -80°C

Temperature Resolution : 1.0°C

Stability : ±0.1°C at-190°C

±0.1°C at -130°C

±0.1°C at -80

Uniformity : ±0.2°C at-190°C

±0.15°C at -130°C

±0.17°C at -80

Controlling Sensor : RTD PT100

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 25 x 300 mm long (2 x 6 mm & 2 x 8 mm holes) of 300 mm insertion depth

Time to Reach Max Temp : 30 Mins

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 300 W

Dimensions of Container : 580(H) x 280(Dia)

Nitrogen Container : 10Ltr.

Dimension of Control Panel : 270(H)x380(W)x270(D)

Weight : 15Kg (without packing)

SPECIFICATIONS

CALsys -190/-80

Ÿ TEMPMET 08, TEMPMET 09

Ÿ Extra Equalizing Block………Part No. EQ2

OPTIONAL ACCESSORIES

Ÿ Reference Standard RTD

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath

temperature and monitoring the PV. Graphical

representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

CALsys -190/-80

0-190 -130 -80

0.05

0.1

0.15

0.2

0.25

Temperature in °C

Tem

pe

ratu

re in

°C

STABILITY UNIFORMITY

-190 to -80°C

KEY FEATURES

ü Large Immersion Depths

ü Wide Operating Range (-190 to -80°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Separate control box

Page 7: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -80/50 is a Highly Stable Stirred Liquid Bath for Calibration RTD / Thermocouple and also for compensation of cold junction. CALsys -80/50 offers the temperature range of -80 to 50°C. It has large tank which is filled with liquid Methanol. The liquid is heated or cooled to the desired temperature. It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This CALsys -80/50 is built using CFC free refrigerants.

-80 to 50°CCALSYS-80/50

HIGH STABILITY BATH

Ÿ Reference Standard PRT...Part No. TPRT-A-300 NABL accredited calibration certificate - 3 point.

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual.

STANDARD ACCESSORIES

Ÿ Methanol 5 ltr. (3050)

OPTIONAL ACCESSORIES

CALsys -80/50

-80 0 50

0.04

0.06

0.08

0.02

0

0.1

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Temp. Range : -80 to 50°C

Stability : ±0.04°C at -80°C

±0.07°C at 0°C

±0.05°C at 50°C

Uniformity : ±0.05°C at -80°C

±0.09°C at 0°C

±0.07°C at 50°C

Temperature Resolution : 0.1°C

Time to Reach Min. Temp. : 2 Hrs

Medium : Methanol

Controlling Sensor : PT-100

Volume : 9 Ltr.

Access Opening : 120 x 120 mm

Depth : 200 mm

Method of control : Digital self tuned PID Controller

Computer Interface : RS - 232

Operating Temperature : 20 to 25°C

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 630 (W) x 1200(H) x 500 (D)mm

Weight : 114.7 Kg (without packing)

SPECIFICATIONS

KEY FEATURES

P Large Immersion Depths

P High Accuracy

P High Stability and Uniformity

P Wide Temperature Range

P PC Interface

P Simple to use and Cost effective

Carrying CaseInterchangeable Inserts

(as per requirement)

Page 8: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -40/50

-40 0 50

0.04

0.06

0.08

0.02

0

0.1

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

CALsys -40/50 is a Highly Stable Stirred Liquid Bath for

Calibration RTD / Thermocouple and also for

compensation of cold junction. CALsys -40/50 offers

the temperature range of -40 to 50°C. It has large tank

which is filled with liquid Methanol. The liquid is

heated or cooled to the desired temperature. It has

better stability & uniformity than dry block bath and

as it uses of stirred liquid. This CALsys -40/50 is built

using CFC free refrigerants.

-40 to 50°CCALSYS-40/50

HIGH STABILITY BATH

Ÿ Reference Standard PRT...Part No. TPRT-A-300 NABL accredited calibration certificate - 3 point.

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual.

STANDARD ACCESSORIES

SPECIFICATIONS

Temp. Range : -40 to 50°C

Stability : ±0.04°C at -40°C

±0.07°C at 0°C

±0.05°C at 50°C

Uniformity : ±0.05°C at -40°C

±0.09°C at 0°C

±0.07°C at 50°C

Temperature Resolution : 0.1°C

Time to Reach Min. Temp. : 1.5 Hrs

Medium : Methanol

Controlling Sensor : PT-100

Volume : 9 Ltr.

Access Opening : 120 x 120 mm

Depth : 200 mm

Method of control : Digital self tuned PID Controller

Computer Interface : RS - 232

Operating Temperature : 20 to 25°C

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 630(W) x 1200(H) x 500(D) mm (Approx.)

Weight : 60 Kg (without packing)

KEY FEATURES

ü Large Immersion Depths

ü High Accuracy

ü High Stability and Uniformity

ü Wide Temperature Range

ü PC Interface

ü Simple to use and Cost effective

Page 9: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -35/200 is a Highly Stable Stirred Liquid Bath

for Calibration RTD / Thermocouple and also for

compensation of cold junction.

CALsys -35/200 offers the temperature range of -35 to

200°C. It has large tank which is filled with liquid

(Water+Methanol/Silicon Oil). The liquid is heated or

cooled to the desired temperature, where

Methanol+Water are used for Negative Temperature

and Silicon Oil is for Heating purpose.

It has better stability & uniformity than dry block bath

and as it uses of stirred liquid. This CALsys -35/200 is

built using CFC free refrigerants.

-35 to 200°CCALSYS-35/200

HIGH STABILITY BATH

Ÿ Reference Standard PRT…Part No.TPRT-A-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME.

Ÿ Operational Manual

STANDARD ACCESSORIES

KEY FEATURESü High Accuracy

ü High Stability and Uniformity

ü Wide Temperature Range

ü PC Interfacing

ü Simple to Use and Cost Effective

Temperature Range : -35 to 200°C

Stability : ±0.04°C at -35°C

±0.05°C at-0°C

±0.06°C at 200°C

Uniformity : ±0.03°C at -35°C

±0.06°C at 0°C

±0.07°C at 200°C

Temperature Resolution : 0.1°C

Time to Reach Max Temp : 2 Hrs

Medium Cooling : Methanol + Water

Medium Heating : Silicon Oil

Controlling Sensor : PT-100

Volume : 10 Ltr.

Access Opening : 105(L) x 105(W)

Depth : 150 mm

Method of Control : Digital self tuned PID Controller

Computer Interface : RS - 232

Operating Temperature : 20 to 25°C

Wetted Part : SS-304

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 558(L) x 350(W) x 462(H)mm

Weight : Approx 45 Kg

SPECIFICATIONS

Ÿ Methanol............10 Ltr. No.(3050-M)

Ÿ Silicon Oil............10L Part No.C200S-LB SO

OPTIONAL ACCESSORIES

0.03

CALsys -35/200

-35 0 200

0.04

0.05

0.06

0.07

0.08

0.02

0.01

0

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

CALsys -35/200

Page 10: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -30/110

0-30 0 110

0.02

0.04

0.06

0.08

0.1

Temperature in °C

Tem

pe

ratu

re in

°C

STABILITY UNIFORMITY

Calsys -30/110 is low temperature dry block furnace.

The dry block furnace based on thermoelectric

cooling circuitry. This model provides an special

design isothermal enclosure (Aluminium block) in

which the thermocouple/RTD can be calibrated

against the temperature of the calibrator. The

calibrator controller uses a precision RTD as a

controlling sensor and controls the well temperature

with thermoelectric cooler. To obtain and maintain a

required temperature the controller varies the power

to the heater via solid-state relay. There is one

electricity driven fan which is situated under the

heating chamber for cooling the heater. The dry block

calibrator was designed for portability, moderate cost

and ease of operation.

LOW TEMPERATURE DRY BLOCK CALIBRATOR

Temperature Range : -30 to 110 °C

Temperature Resolution : 0.1°C

Stability : ±0.04°C at -30°C

±0.06°C at 0°C

±0.07°C at 110°C

Uniformity : ±0.05°C at -30°C

±0.07°C at 0°C

±0.08°C at 110°C

Controlling Sensor : Precision PRT

Method of Control : Digital self tuned

PID Controller

Fixed Insert Construction : 1 hole of 8mm and

2 hole of 6.5mm

with 120mm length

Time to Reach Max/Min Temp : 10/20 Mins

Operating Temperature : 20 to 25°C

Computer Interface : RS - 232

Power Requirement : 230 VAC, 500 W

Dimensions : 380(H) x 170(W) x

188(D) mm

Weight : 11.70Kg (without

packing)

SPECIFICATIONS

-30 to 110°CCALSYS-30/110

Carrying CaseInterchangeable Inserts

(as per requirement)

ü Wide Operating Range (-30 to110°C)

ü High Stability

ü PC Interfacing

ü Simple to use and cost effective

ü Portability

ü Low temperature calibration facility upto -30°C

ü Conveniently handle and calibration

ü Light Weight

KEY FEATURES

Page 11: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys -15 / 110 offers medium temperature range

from -15 to 110°C. It is a highly stable standard

temperature source for ca l ibrat ing RTD

/thermocouples. It has peltier elements to generate

stable temperature in the well. The comparison

volume is a metallic block of aluminum, which has

diameter of 24mm and 120mm length. The

temperature of the calibrator is set and controlled by

a self tuned PID controller with automatic super fine

adjustment.

PELTIER BASED TEMPERATURE CALIBRATOR

Ÿ Reference standard PRT......part no.TPRT -A-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - cal soft including for setting bath

temperature and monitoring the PV. graphical

representations of PV/time with 2 hours data logging.

Ÿ Operational manual

Ÿ Carry case

STANDARD ACCESSORIES

Temperature Range : -15 to 110°C

Temperature Resolution : 0.1°C

Stability : ±0.03°C at -15°C

±0.05°C at 0°C

±0.07°C at 110°C

Uniformity : ±0.05°C at -15°C

±0.07°C at 0°C

±0.09°C at 110°C

Controlling Sensor : Precision PRT

Method of Control : Digital self tuned PID

Controller

Insert Construction : Dia 24x120 mm long,

3x6 mm hole with

115mm insertion

depth

Time to Reach Max/Min Temp : 25 Mins

Operating Temperature : 20 to 25°C

Computer Interface : RS - 232

Power Requirement : 230 VAC, 500 W

Dimensions : 380(H) x 170(W) x

188(D) mm

Weight : 11.70 Kg (without

packing)

SPECIFICATIONS

-15 to 110°CCALSYS-15/110

CALsys -15/110

0-15 0 110

0.02

0.04

0.06

0.08

0.1

Temperature in °C

Tem

pe

ratu

re in

°C

STABILITY UNIFORMITY

ü Wide Operating Range (-15 to 110°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Portability

KEY FEATURES

Carrying CaseInterchangeable Inserts

(as per requirement)

Page 12: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 120SP offers medium temperature range from 0 to 120°C. It is a highly stable standard temperature source for calibrating RTD /thermocouples. It has peltier elements to generate stable temperature in the well. Use as a dry block & liquid bath using magnetic stirrer in one model. The comparison volume is a metallic block of aluminum, which has diameter of 24mm and 100mm length. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment.

0 to 120°CCALSYS120SP

PELTIER BASED TEMPERATURE CALIBRATOR

Temperature Range : 0 to 120°C

Temperature Resolution : 0.1°C

Stability : ± 0.03°C at 0°C

±0.05°C at 50°C

±0.07°C at 120°C

Uniformity : ±0.05°C at 0°C

±0.07°C at 50°C

±0.09°C at 120°C

Controlling Sensor : Precision PRT

Medium : Silicon Oil (for liquid bath)

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 24 x 100 mm long, 3 x 6 mm hole

Time to Reach Max/Min Temp : 25 Mins

Operating Temperature : 20 to 25°C

Computer Interface : RS - 232

Power Requirement : 230 VAC, 500 W

Dimensions : 380(H) x 170(W) x 188(D) mm

Weight : 14 Kg (without packing)

SPECIFICATIONS

Carrying CaseInterchangeable Inserts

(as per requirement)

CALsys 120SP

0 50 120

0.04

0.06

0.08

0.02

0

0.1

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Ÿ Reference Standard PRT......Part No.TPRT -A-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

ü Wide Operating Range (0 to120°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Portability

KEY FEATURES

Page 13: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 300SP calibration bath is a highly stable

standard stirred liquid bath for calibrating

RTDs/Thermocouples and other temperature sensors

in the laboratory. The temperature of the bath is set

and controlled by a self tuned PID controller with

automatic super fine adjustment.

The unique features is portability with very high

stability and uniformity. The medium used in the bath

is silicon oil.

HIGH ACCURACY LIQUID CALIBRATION BATHGENERAL

50 to 250°CCALsys300 SP

Ÿ Silicon Oil......... Part No.C300S-LB-SO

Ÿ Reference Standard PRT……Part No.TPRT-A-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath

temperature and monitoring the PV. Graphical

representations of PV/TIME with 2 hours data

logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

Silicon Oil..........Part No C200S-LB-SO

OPTIONAL ACCESSORIES

Temperature Range : 50 to 250°C

Temperature Resolution : 0.1°C

Stability : ±0.05°C at 50°C

±0.07°C at 150°C

±0.1°C at 250°C

Uniformity : ±0.1°C at 50°C

±0.15°C at 150°C

±0.2°C at 250°C

Controlling Sensor : Precision PRT (PT-100)

Method of Control : Digital self tuned PID Controller

Medium of Heating : Silicon Oil

Time to Reach Max Temp : 45 Mins

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 600(H) x 350(W) x 550(D) mm

Access Opening : 100mm x 100mm

Depth : 150mm

Weight : 20 Kg(without packing)

SPECIFICATIONS

Note : Large depth and Access opening available on customer request.

ü Large Immersion Depths

ü Wide Operating Range (50 to 250°C)

ü High Stability and Uniformity

ü PC interfacing

ü Simple to use and cost effective

KEY FEATURES

CALsys 300SP

50 150 250

0.10

0.15

0.20

0.05

0

0.25

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Page 14: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Provide superior thermal environment for probe immersion as no air gap exist between the probe and the medium Thermal coupling is therefore much better than the alternatives described, and the stirring results in very even heat distribution throughout the medium. Methanol is used for temperature below 0°C, water from 0 to 80°C and silicon oil for upto 250°C. We have seven types of liquid baths given below. CALsys 250 calibration bath is a highly stable standard stirred l iquid bath for calibrating RTDs / Thermocouples and other temperature sensors in the laboratory. The temperature of the bath is set and controlled by a self tuned PID controller with automatic super fine adjustment. The unique features is portability with very high stability and uniformity. The medium used in the bath is silicon oil.

50 to 250°CCALSYS250

HIGH ACCURACY LIQUID CALIBRATION BATH

SPECIFICATIONS

Temperature Range : 50 to 250°CTemperature Resolution : 0.1°CStability : ±0.015°C at 50°C ±0.025°C at 150°C ±0.05°C at 250°CUniformity : ±0.02°C at 50°C ±0.04°C at 150°C ±0.06°C at 250°CControlling Sensor : Precision PRT (PT-100)Method of Control : Digital self tuned PID

ControllerMedium of Heating : Silicon OilTime to Reach Max Temp : 30 MinsComputer Interface : RS - 232Operating Temperature : 20 to 45°CPower Requirement : 230 VAC, 1.0 KWDimensions : 360(H) x 185(W) x

285(D) mmAccess Opening : 90 mm DiaDepth : 140 mmRemovable Insert : 6 holes of 15 mm DiaConstruction Weight : 12 Kg (without

packing)Volume : 900 mlWetted Parts : Aluminium

KEY FEATURES

ü Large Immersion Depths

ü Wide Operating Range (50 to 250°C)

ü High Stability and Uniformity

ü PC interfacing

ü Simple to use and cost effective

ü Portability

0

CALsys 250

50 150 250

0.010.020.030.040.050.060.070.080.09

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Ÿ Silicon Oil......... Part No.C300S-LB-SO

Ÿ Reference Standard PRT……Part No.TPRT-A-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath

temperature and monitoring the PV. Graphical

representations of PV/TIME with 2 hours data

logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

Page 15: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 650

050 350 650

0.02

0.04

0.06

0.08

0.1

Temperature in °C

Tem

pe

ratu

re in

°C

STABILITY UNIFORMITY

CALsys 650 offers medium temperature range from 50 to 650°C. It is a highly stable standard furnace for calibrating thermocouples / RTD.

The comparison volume is a metallic block of special material, which has diameter of 32mm and 150mm long The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment.

50 to 650°CCALSYS650

PORTABLE CALIBRATOR

Temperature Range : 50 to 650°C

Temperature Resolution : 0.1°C

Stability : ±0.025°C at 50°C

±0.035°C at 350°C

±0.07°C at 650°C

Uniformity : ±0.04°C at 50°C

±0.07°C at 350°C

±0.09°C at 650°C

Controlling Sensor : T/C “N” TYPE

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 32 x 150 mm long with 4 holes of 6.5 x 120 mm insertion depth

Time to Reach Max Temp : 25 Mins

Cooling Time 650 to 100°C : 70 Mins

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 1 KW

Dimensions : 325(H) x 185(W) x 265(D) mm

Weight : 8.80 Kg (without packing)

SPECIFICATIONS

Ÿ Customized Equalizing Block....Part No. EQ1

OPTIONAL ACCESSORIES

Carrying CaseInterchangeable Inserts

(as per requirement)

KEY FEATURESü Large Immersion Depths

ü Wide Operating Range (50 to 650°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

Ÿ Reference Standard Thermocouple ('K' Type T/C)…… Part No. TTCK-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

Page 16: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys FB offers medium temperature range from 50 to 650°C. It is a high stable fluidized bath for calibration thermocouple & RTD. It has been designed for medium temperature calibration with high satiability and maximum uniform temperature zone. Alumina powder is used as medium. Metallic probes are used with probe holder for calibration which is 280 mm long with 8mm diameter. Temperature of furnace is set and controlled by self tuned PID controller with automatic super fine adjustment.

SPECIFICATIONS

Temperature Range : 50 to 650°CDed Bed : 0.05°CStability : ±1.0°CDisplay Resolution : 0.1°CType of Control : Digital self Tuned

PID ControllerSensor Type : N type

thermocoupleTime to reach Max. Temp. : 105 MinutesAir pressure kPa (psi) : 420 (60)Weight of medium : 16 kg (35 lbs)Working volume : 150 x 385mmOverall Size L x W x H : 870 x 515 x

600mmWeight : 84 kg (185 lbs)

(without Packing)Serial communication : RS 232Power Requirement : 230VAC, 3.0 KWOperating temp. : 20 to 45°C

50 to 650°CCALSYSFB

FLUIDIZED BATH

Ÿ Reference Standard Thermocouple ('N' type T/C)....Part No. TTCN-300

STANDARD ACCESSORIES

Ÿ Customized Equalizing Block....Part No. EQ1

OPTIONAL ACCESSORIES

ü High Uniform zone

ü Wide Operating Range (50°C - 650°C)

ü High Stability

ü No. of Sensor Calibrated Simultaneously

KEY FEATURES

Page 17: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 1200 offers high temperature range from 250 to 1200°C. It is a highly stable standard furnace for calibrating Thermocouples / RTD. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries. The comparison volume is a metallic block of special material, which is 37 mm in diameter with 215 mm long. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Version with 3 zone furnace is also available.

250 to 1200°CCALSYS1200

PORTABLE THERMOCOUPLE CALIBRATOR

SPECIFICATIONS

Temperature Range : 250 to 1200°CTemperature Resolution : 1.0°CStability : ±0.1°C at 250°C ±0.2°C at 700°C ±0.3°C at 1200°CUniformity : ±0.20°C at 250°C ±0.24°C at 700°C ±0.36°C at 1200°CControlling Sensor : PT/RH-PT T/CMethod of Control : Digital self tuned

PID ControllerInsert Construction : Dia 37 x 215 mm

long (2X6mm & 2X8 mm holes) of 160mm insertion depth

Time to Reach Max Temp : 1.5 HrsCooling Time 1200°C to 250°C : 180 MinsComputer Interface : RS - 232Operating Temperature : 20 to 45°CPower Requirement : 230 VAC, 1.5 KWDimensions : 405(H) x 205(W) x

285(D) mmWeight : 13.65 Kg (without

packing)

Ÿ Customized Equalizing Block....Part No. EQ1

OPTIONAL ACCESSORIES

Carrying CaseInterchangeable Inserts

(as per requirement)

0.25

0.20

0.15

0.10

0.05

0

CALsys 1200

0.30

0.35

0.40

0.45

250 700 1200

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

KEY FEATURESKEY FEATURESü Large Immersion Depths

ü Wide Operating Range (250 to 1200°C)

ü High Stability

ü PC interfacing

ü Simple to Use and Cost Effective

Ÿ Reference Standard Thermocouple ('N'Type T/C)……Part No. TTCN-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

Page 18: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURESü Large Immersion Depths

ü Wide Operating Range (300 to 1200°C)

ü High Stability

ü PC interfacing

ü Simple to Use and Cost Effective

CALsys 1200L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment. The standard insert is a metallic block of special material, which is 37mm in diameter with 240 mm long and can hold up to four thermocouples.

It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive, material processing industries & laboratories. Special Version with 3 zone furnaces are available.

Temperature Range : 300 to 1200°C

Temperature Resolution : 1.0°C

Stability : ±0.1°C at 300°C

±0.2°C at 700° C

±0.35°C at 1200°C

Uniformity : ±0.15°C at 300°C

±0.25°C at 700°C

±0.4°C at 1200°C

Controlling Sensor : Precision PT/RH-PT T/C

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 37 x 240 mm long (2X6mm & 2X8 mm holes) of 160mm insertion depth

Time to Reach Max Temp : 1.5 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 590(H) x 450(W) x 530(D) mm

Weight : 50 Kg (without packing)

SPECIFICATIONS

300 to 1200°CCALSYS1200L

HIGH STABILITY BLOCK FURNACE

Ÿ Customized Equalizing Block....Part No. EQ1

OPTIONAL ACCESSORIES

Optional Black

0.25

0.20

0.15

0.10

0.05

0

CALsys 1200L

0.30

0.35

0.40

0.45

300 700 1200

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Ÿ Reference Standard Thermocouple ('N' Type

T/C)……Part No. TTCN-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath

temperature and monitoring the PV. Graphical

representations of PV/TIME with 2 hours data

logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

Page 19: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 1200 3Z calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of each zone of the furnace is set and controlled by a self tuned PID controller(master + Slave) with automatic super fine adjustment. The standard insert is a metallic block of special material, which is 37mm in diameter with 240 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive, material processing industries & laboratories.

Temperature Range : 300 to 1200°C

Temperature Resolution : 1.0°C

Stability : ±0.1°C at 300°C

±0.2°C at 750° C

±0.35°C at 1200°C

Radial Uniformity : ±0.15°C at 300°C

±0.25°C at 750° C

±0.40°C at 1200°C

Axial Uniformity : ±1.0°C up to 80mm at 1200°C

Controlling Sensor : Precision PT/RH-PT T/C

No. of Zone : Three

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 37 x 240 mm long

(2X6 mm & 2X8 mm holes) of 160mm insertion depth

Time to Reach Max Temp : 1.5 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 2.0 KW

Dimensions : 500(H) x 400(W) x 490(D) mm

Weight : 50Kg (without packing)

SPECIFICATIONS

300 to 1200°CCALSYS1200 3Z

HIGH STABILITY BLOCK FURNACE

Ÿ Customized Equalizing Block....Part No. EQ1

OPTIONAL ACCESSORIES

Optional Black

KEY FEATURESü Large Immersion Depths

ü Wide Operating Range (300 to 1200°C)

ü High Stability

ü PC interfacing

ü Simple to Use and Cost Effective

0.5

0.4

0.3

0.2

0.1

0

CALsys 1200 3Z0.6

300 750 1200

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Ÿ Reference Standard Thermocouple ('N' Type T/C)……Part No. TTCN-300

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

Page 20: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 1500L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment. The standard insert is a Ceramic Tube, which is 37 mm in diameter with 245 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries and laboratories.

Temperature Range : 500 to 1500°C

Temperature Resolution : 1.0°C

Stability : ±0.4°C at 500°C

±0.7°C at 1000°C

±1.0°C at 1500°C

Uniformity : ±0.6°C at 500°C

±0.8°C at 1000°C

±1.2°C at 1500°C

Controlling Sensor : PT-RH/PT T/C

Method of Control : Digital self tuned PID Controller

Insert Construction : Dia 37 x 245 mm long (2X6mm & 2X8 mm holes) of 140mm insertion depth

Heaters : Silicon Carbide Spiral Rod Heater

Time to Reach Max Temp : 2 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 3.0 KW

Dimensions : 590(H) x 450(W) x 530(D) mm

Weight : 55 Kg (without packing)

SPECIFICATIONS

500 to 1500°CCALSYS1500L

HIGH STABILITY BLOCK FURNACE

Ÿ Reference Standard Thermocouple (PT-RH/PT 'R' Type T/C) ……… Part No. TTCR-300

Ÿ Extra Equalizing Block………Part No. EQ2

OPTIONAL ACCESSORIES

1.0

0.8

0.6

0.4

0.2

0

CALsys 1500L1.2

500 1000 1500

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

KEY FEATURES

ü Use of Silicon Carbide Spiral Rod Heaters

ü Large Immersion Depths

ü Wide Operating Range (500 to 1500°C)

ü High Stability

ü PC interfacing

ü Simple to Use and Cost Effective

STANDARD ACCESSORIES

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

Page 21: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 1700L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory.

The temperature of the furnace is set and controlled by a self tuned advanced PID controller with automatic super fine adjustment. The standard insert is a Ceramic Tube, which is 37 mm in diameter and 240 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries and laboratories.

Temperature range : 500 to 1700°C

Voltage : 230 V AC

Power : Maximum

Supply Frequency : 50/60 Hz

Resolution : 0.1°C

Stability : ±0.5°C at 500°C

±1.0°C at 1200°C

±1.5°C at 1700°C

Uniformity : ±0.6°C at 500°C

±1.4°C at 1200°C

±1.9°C at 1700°C

Controlling sensor : B type T/C Duplex

Time to reach max. Temp. : 3 hours

Operating Temperature : 20 to 45°C

Controller Specifications : Eurotherm P104 series

Over temperature protection : Autonics controller with B Type T/C

Stabilization Time : 15 to 20 Min.

Dimensions : 640(H) x 500(W) x 550(D) mm

Insert Construction : 2 x 6.5, 2 x 8.5 mm with 225mm depth

Weight : 80kg (without packing)

SPECIFICATIONS

500 to 1700°CCALSYS1700L

HIGH TEMPERATURE BLOCK FURNACE

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

Ÿ Reference Standard Thermocouple (PT-RH/PT 'B' Type T/C) ……… Part No. TTCB-300

Ÿ Extra Equalizing Block………

Ÿ Black Body Cavity……….Part No. EQ3

OPTIONAL ACCESSORIES

1

0.5

0

CALsys 1700L

1.5

2

500 1200 1700

Temperature in °C

Tem

per

atu

re in

°C

STABILITY UNIFORMITY

Page 22: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Extended area black body is defined by the large emitting surface area precise temperature control with good uniformity. The blackbody is designed to provide infrared radiation as an ideal blackbody emitter. Because of the large uniform surface area the

body called extended area black body.

Tempesens offers extended area black body with two emitter size small and large have different temperature range. It desigined accordingly temperature measurement and calibration both are performed in the radiation head and transfer digitally to the controller. It is designed highly standard and stable black body for testing of infrared sensors and thermal detecting devices. We sepeartly provide high programming controller with black body source. High accuracy chamber have designed separately. The temperature of the furnace is set or change by the controller.

LBB100CH & LBB11CH

Ÿ Independent controller with calibrated area.

Ÿ Monitored controlling device.

Ÿ Portable controller.

Ÿ Serial communication and computer interfacing by port

Ÿ Rs-232.

Ÿ Quick and convenient calibration technique.

PROPERTIES

EXTENDED AREA BLOCK BODY

Temperature Range : 15 to 100° CDisplay Resolution : 0.01° CStability : ±0.5°CUniformity : ±2°CControlling Sensor : RTDEmissivity : 0.97Emissive Head : 1000x1000 mmPower Requirement : 230VACMethod of Control : Digital Self tuned PID

ControllerComputer Interface : Rs-232/USBDimensions : 1450 (H) x 1450 (W) x 600

(D) mmWeight : 35 kg

LBB100CH

KEY FEATURES

ü Large area emitter size

ü Good uniformity

ü Capable of operating at wide temperature range

ü High resolution & PC Interfacing

ü Better stability

ü High accuracy

LBB11CH

Temperature Range : 0 to 140° CDisplay Resolution : 0.01°CStability : ±0.01°CUniformity : ±0.08°CControlling Sensor : RTDEmissivity : 0.97Emissive Head : 100x100 mmPower Requirement : 220VAC, 500WMethod of Control : Digital self tuned PID

ControllerComputer Interface : Rs-232/USBDimensions : 610 (H) x 550 (W) x 610

(D) mmWeight : 30 kg

Page 23: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

CALsys 110BB calibration source is a highly stable

standard portable black body furnace for calibrating

non contact IR thermometer for the temperature

range of 10 to 110°C.

The unique feature of this portable black body furnace

is large temperature controlled black body target with

a size of 80 mm dia which offer large view area for IR

thermometer.

The emissivity of the target is 0.95(±0.01). The

temperature of the furnace is set and controlled by a

self tuned PID controller with automatic super fine

adjustment.

10 to 110°CCALSYS110BB

PORTABLE BLACK BODY

Temperature Range : 10 to 110°C

Temperature Resolution : 0.1°C

Stability : ±0.05°C at 10°C

±0.07°C at 60°C

±0.1°C at 110°C

Controlling Sensor : Precision PRT

Method of Control : Digital self tuned PID Controller

Emissivity : 0.95 ±0.01

Time to Reach Max Temp : 25 Mins

Computer Interface : RS - 232

Operating Temperature : 20 to 25°C

Power Requirement : 230 VAC, 0.5 KW

Dimensions of cabinet : 330(H) X 355(W) X 225(D) mm

Cavity : High Emissive Painted Aluminum Plate

Aperture : 80 mm dia

Weight : 12Kg (without packing )

SPECIFICATIONS

CALsys 110BB

10 60 110

0.10

0.15

0.20

0.05

0

0.25

Temperature in °C

Tem

per

atu

re in

°C

STABILITY

Ÿ Carry Case

Ÿ Operational Manual

STANDARD ACCESSORIES

Ÿ Master Pyrometer

OPTIONAL ACCESSORIES

ü Large Aperture Area

ü Below Ambient Operating Range (10 to 110°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Portability

KEY FEATURES

Page 24: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Ÿ Master Pyrometer

OPTIONAL ACCESSORIES

CALsys 500BB calibration source is a highly stable

standard portable black body furnace for calibrating

non contact IR thermometer for the temperature

range of 50 to 500°C.

The unique feature of this portable black body furnace

is large temperature controlled black body target with

a size of 100 mm dia which offer large view area for IR

thermometer.

The emissivity of the target is 0.95(±0.01). The

temperature of the furnace is set and controlled by a

self tuned PID controller with automatic super fine

adjustment.

50 to 500°CCALSYS500BB

PORTABLE BLACK BODY

Temperature Range : 50 to 500°C

Temperature Resolution : 0.1°C

Stability : ± 0.5°C at 50°C

±0.8°C at 250°C

±1.0°C at 500°C

Controlling Sensor : T/C “N” type

Method of Control : Digital self tuned PID Controller

Emissivity : 0.95 ±0.01

Time to Reach Max Temp : 45 Mins

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 1.0 KW

Dimensions of cabinet : 270(H) X 360(W) X 270(D) mm

Target Size : Dia - 100 mm (Ridged Aluminum Plate)

Weight : 10Kg (without packing)

SPECIFICATIONS

CALsys 500BB

50 250 500

0.4

0.6

0.8

0.2

0

1.0

Temperature in °C

Tem

per

atu

re in

°C

STABILITY

ü Large Aperture Area

ü Wide Operating Range (50 to 500°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Portability

KEY FEATURES

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

Ÿ Carry Case

STANDARD ACCESSORIES

Page 25: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

ü Wide Operating Range (300 to 1200°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Sighting tube

KEY FEATURES

CALsys 1200BB calibration source is a highly stable

standard black body furnace for calibrating non

contact IR thermometer for the wide temperature

range of 300 to 1200°C.

The unique feature of this black body furnace is large

temperature controlled black body target with a

diameter of 40 mm and 85mm which offer large view

area for IR thermometer.

The emissivity of the target is 0.99(±0.01).The

temperature of the calibrator is set and controlled by

a self tuned PID controller with automatic super fine

adjustment.

HIGH STABILITY BLACK BODY FURNACE

Temperature Range : 300 to 1200°C

Temperature Resolution : 1.0°C

Stability : ±0.2°C at 300°C

±0.3°C at 800°C

±0.5°C at 1200°C

Controlling Sensor : Precision PT/RH-PT T/C

Method of Control : Digital self tuned PID Controller

Time to Reach Max Temp : 1.5 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 2.5KW

Dimensions of cabinet : 590(H) x 450(W) x 530(D) mm

Radiation Cavity Type : Silicon Carbide

Dimension of cavity : 46 mm Dia x 85mm depth

External Aperture : 40 mm dia

Weight : 5 0 K g ( w i t h o u t packing)

SPECIFICATIONS

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

Ÿ Master Pyrometer

Ÿ Black Body Cavity…………Part No. EQ3

OPTIONAL ACCESSORIES

300 to 1200°CCALSYS1200BB

CALsys 1200BB

300 800 1200

0.2

0.3

0.4

0.1

0

0.5

Temperature in °C

Tem

per

atu

re in

°C

STABILITY

Page 26: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Ÿ Black Body Cavity…….Part No. EQ3

OPTIONAL ACCESSORIES

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

CALsys 1500BB calibration source is a highly stable

standard black body furnace for calibrating non

contact IR thermometer for the wide temperature

range of 500 to 1500°C.

The unique feature of this black body furnace is large

temperature controlled black body target with a

diameter of 40 mm and 85 mm depth which offer large

view area for IR thermometer.

The emissivity of the target is 0.99(±0.01). The

temperature of the calibrator is set and controlled by a

self tuned PID controller with automatic super fine

adjustment.

HIGH STABILITY BLACK BODY FURNACE

CALsys 1500BB

500 1000 1500

0.4

0.6

0.8

0.2

0

1.0

Temperature in °C

Tem

per

atu

re in

°C

STABILITY

500 to 1500°CCALSYS1500BB

ü Use of Silicon Carbide Spiral Rod Heaters

ü Wide Operating Range (500 to 1500°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

ü Sighting tube

KEY FEATURES

Temperature Range : 500 to 1500°C

Temperature Resolution : 1.0°C

Stability : ±0.4°C at 500°C

±0.7°C at 1000°C

±1.0°C at 1500°C

Controlling Sensor : PT-RH/PT T/C

Method of Control : Digital self tuned PID Controller

Heaters : Silicon Carbide Spiral Rod Heater

Time to Reach Max Temp : 2.5 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 3.5 KW

Dimensions of cabinet : 590(H) x 450(W) x 530(D) mm

Radiation Cavity Type : Silicon Carbide,

Dimension of cavity : 46 mm Dia x 85mm depth

External Aperture : 40 mm dia

Weight : 50 Kg (without packing)

SPECIFICATIONS

Page 27: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Ÿ Master Pyrometer

Ÿ Black Body Cavity………. Part No. Eq3

OPTIONAL ACCESSORIES

Ÿ NABL accredited calibration certificate - 3 point

Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.

Ÿ Operational Manual

STANDARD ACCESSORIES

CALsys 1700BB calibration source is a highly stable

standard black body furnace for calibrating non

contact IR thermometer for the wide temperature

range of 500 to 1700°C.

The unique feature of this black body furnace is large

temperature controlled black body target with a

diameter of 29 mm which offer large view area for IR

thermometer.

The emissivity of the target is 0.97(±0.01). The

temperature of the calibrator is set and controlled by a

self tuned PID controller with automatic super fine

adjustment.

HIGH STABILITY BLACK BODY FURNACE

500 to 1700°CCALSYS1700BB

SPECIFICATIONSTemperature Range : 500 to 1700°C

Temperature Resolution : 1°C

Stability : ±0.7°C at 500°C

±1.4°C at 1200°C

±2.0°C at 1700°C

Controlling Sensor : Precision PT/RH-PT T/C

Heaters : MoSiO2

Method of Controlling : Digital self tuned PID Controller

Time to Reach Max Temp : 3 Hrs

Computer Interface : RS - 232

Operating Temperature : 20 to 45°C

Power Requirement : 230 VAC, 3 KW

Dimensions of cabinet : 640(H) x 500(W) x 550(D) mm

Black Body Cavity Aperture : 29 mm, End closed tube

Weight : 80Kg (without packing)

ü Use of Molybdenum Disilicide Heaters (MoSiO2)

ü Wide Operating Range (500 to 1700°C)

ü High Stability

ü PC interfacing

ü Simple to use and cost effective

KEY FEATURES

CALsys 1700BB

500 1200 1700

1.0

1.5

2.0

0.5

0

2.5

Temperature in °C

Tem

per

atu

re in

°C

STABILITY

Page 28: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURES

ü Water flow failure

ü Increase in water temperature

ü Argon gas flow failure

ü Over current

600 to 3000°CFASTCAL3000

FastCAL 3000 is a high temperature blackbody source

with a capacity to produce high temperature using

high emissivity emitter(graphite tube) and at the

same time stabilize at the required temperature

within a few minutes.

It is mainly used to calibrate non-contact temperature

sensors. Step change in temperature is achievable

within seconds. The graphite tube has an emitter

diameter of 25mm (1.00") and an emissivity of +0.995

±0.005. Target temperature is sensed by a non contact

temperature sensor/Pyrometer which gives a

feedback to PID controller to regulate the cavity

temperature precisely to the desired set points.

Remote set point is achieved via RS-232 C

communication port.

All safety features to protect equipment and operator

are easily accessible.

SPECIFICATIONS

Temperature Range 600°C to 3000°C (1112°F - 5432°F)

Wavelength 1000 nm or 1600 nm (Pyrometer)

Cavity Temp. Accuracy ± 0.25 % of set temperature ±1°C

Temperature Resolution 0.1°C

Temperature Stability ±1°C

Emissivity 0.995 ±0.005

Cavity Closed end graphite tube Length - 292mm Heated Length - 127mm

Heating Aperture/Cavity Dia Graphite tube with argon gas purge dia 25mm

CoolingWater cooled, recommended re-circulation system.All units include water cooled reflector around the blackbody to reduce the heat load to the room. A Chiller unit will be provided with the system.

Purge Gas Dry Argon gas flow with 7-10 LPM

Heating Time Approx 5 Minute from ambient to 3000°C

Safety Interlocks Cooling water over temperature, Low purge gas flow, low cooling water flow rate, over current and over temperature protection.

Controlling Sensor Pyrometer

Method of Control PID controller Eurotherm make(Option - HMI & Data Logging)

Remote Controller Set Point control and temperature monitoring by RS-232/Rs-485

Ambient Temperature 0°C to 50°C

Power 230 VAC ±10°C 50Hz (Three phase/Two Phase/Single Phase)

Dimension 1700mm(H) x 900mm(W) x 1200mm(D)

Weight 300 Kg

Page 29: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURES

ü 0°C Thermoelectric reference unit

ü Eliminates Old Fashioned “Ice Bath”

ü Versatile use in industries, Laboratories, Instrument shop

ü NABL Traceable Calibration Available

KEY FEATURES

ü 60°C Thermoelectric reference unit

ü Versatile use in factory, Laboratory, Instrument Shop

ü Rugged Outer case for safe Portability

ü NABL Traceable Calibration Available

CALREF 0

Reference Junction Temp. : 0°C(Standard)

Types of T/C : J, K, T, E, N, R, S, B

Accuracy : ±0.1°C, Errors can be compensated by adjusting controller setting

Stability : ±0.03°C

Stabilization Time : 15 Mins

Capacity : 20 No (User Defined)

Resolution : ±0.01°C

Dimension : 315(H) x 305(W) x 332(D)mm

Weight : 13Kgs

Power Supply : 230 VAC, 50 Hz

Carry Case : Aluminium modular box

SPECIFICATIONS

CALREF 60

SPECIFICATIONS

Temperature Range : +10 to 90

Types of T/C : J, K, T, E, N, R, S, B

Accuracy : ±0.5°C, Errors can be compensated by adjusting controller setting

Stability : ±0.05°C

Stabilization Time : 10 Mins

Capacity : 6-24 Channel (User Defined)

Max. Capacity : 48 Channel

Resolution : ±0.1°C

Dimension(CRCA) : 350(H) x 350(W) x 210(D) mm

Dimension(FRP) : 330(H) x 330(W) x 180(D) mm

Weight : 15Kg(CRCA), 10Kg(FRP)

Power Supply : 230 V AC, 50/60 Hz / 24 V DC

Page 30: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURES

ü 2 4 C h a n n e l C a l i b r a t i o n ( 1 2 N o . f o r thermocouples & 12 No. for RTD's)

ü Includes Easy to use Connectors

ü Internal CJC compensation

ü Data Logging of selected channel

ü Communicat ion wi th CALsys Model .& PC/Laptop

242424

The Autocal 24 is an automatic temperature calibration system for the thermocouple and RTD's. The system consist of furnaces, the autocal device and PC software, which together contribute to the whole cycle of auto calibration process.

Each thermocouple and RTD input is designated as channel for the system. The system accept 24 channels, 12 thermocouples & 12 RTD's. The connection for these channels through special type of locking connectors. The channel switching can be done with PC software/LCD display via touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generate a report of actual calibrated values for the inputs.

ü Display LCD Display with Touch Screen

ü Resolution (°C) 0.01°C

ü Resolution (mV) 6 ½ digit

ü Display Unit °C / °F / mV / ohms

ü Mounting 19” rack / suitable for carry case

ü Calibration With accredited calibration certificates

ü Main Supply 230 VAC, 50 Hz

SPECIFICATIONS

AUTOMATIC CALIBRATION SYSTEM

AUTOCAL SYSTEM

Page 31: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

KEY FEATURESü High stability

ü High accuracy of RTD measurement 0.01°C

ü High accuracy of T/C measurement 0.1°C

ü High Resolution

ü Measuring inputs

ü 10 Thermocouples B, C, D, E, R, S, T, N, J, K

ü 6 RTD's PT-100, PT-10, PT-50, PT-500, PT-200, PT-1000

ü Thermocouple reference junction external, internal and off

ü Units °C/ °F

ü Data Logging 4000 values

ü Suitable for 2/3/4 wire RTD.

Extended area black body is defined by the large

emitting surface area precise temperature control

with good uniformity. The blackbody is designed to

provide infrared radiation as an ideal blackbody

emitter. Because of the large uniform surface area the

body called extended area black body.

Tempesens offers extended area black body with two

emitter size small and large have different

temperature range. It desigined accordingly

temperature measurement and calibration both are

performed in the radiation head and transfer digitally

to the controller. It is designed highly standard and

stable black body for testing of infrared sensors and

thermal detecting devices. We sepeartly provide high

programming controller with black body source. High

accuracy chamber have designed separately. The

temperature of the furnace is set or change by the

controller.

CALSYSC-4004

PRECISION THERMOMETER

Display : 192x64 LCD Graphic Panel with back light

Input : 2 Channels for RTD and Thermocouple via lemo 1-S series connector

Working Temperature : Less than 95% non condensing condition

Storage Temperature : -20 to +55 °C

Mains Supply : 85-264 VAC / 120-370 VDC 47-63 Hz

Data Logging : Up to 4000 single channel values can be stored along with date and time

Dimensions : 224(H) x 318(W) x 90(D) mm

SPECIFICATIONS

Ÿ Direct Thermocouple measurement

Ÿ Direct RTD measurement

APPLICATIONS

Page 32: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Specifications

RTD + T/C type RTD + T/C range Accuracy

Pt100 0 0-200 C ~ +850 C ±0.05°C

S 0 00 C ~ 1768 C ±2.40°C

B 300°C ~ +1820°C ±2.40°C

T 0 0-200 C ~ +400 C ±1.20°C

J 0 0-210 C ~ +1200 C ±1.20°C

R 0°C ~ +1768°C ±2.40°C

E 0 0-200 C ~ +1000 C ±1.20°C

N -200°C ~ +1300°C ±1.80°C

K 0 0-200 C ~ +1372 C ±1.50°C

TEMPMET 08 - RTD + THERMOCOUPLE

INPUT

Thermocouple : K, S, E, T, J, R, B, N

RTD : Pt100

Unit : °C, F, K

Resolution : 0.0°C/0.0°F

Specifications

TEMPMET 09 - RTD + THERMOCOUPLE

RTD + T/C type RTD + T/C range Accuracy

Pt100 0 0-200 C ~ +850 C ±0.02% RDG +0.060°C

mA -2.0 ~ +24.0mA ±0.03% RDG +3µA

J -210 ~ +1200°C ±0.50°C

S -0.0 ~ 1768°C ±0.8°C

E -200 ~ +1000°C 0.40°C

T -200 ~ +400°C ±0.50°C

K -200°C ~ +1372°C ±0.50°C

R 0.0 ~ 1768°C ±0.8°C

mV -100.0 ~ +200.0mV ±0.015% RDG +10µV

Cu100 0 0-50 C ~ +150 C ± 0.060°C

Cu50 0 0-50 C ~ +150 C ± 0.080°C

Pt1000 0 0-140 C ~ +320 C -

Ω -0.000 ~ 2200 Ω ±0.02% RDG +50mΩ

B 300 ~ +1820°C ±0.9°C

N -200 ~ +1300°C ±0.50°C

INPUT

Thermocouple : K, S, E, T, J, R, B, N

RTD : Pt1000, Cu50, Cu10

mV : -100 to 200mV

mA : -2 to 24 mV

Resistance : 0 to 500 Ohms

Unit : Ohms, mA, mV, °C, F, K

Resolution : 0.000°C/0.000°F, 0.000

A/V/mA/mV

PRECISION THERMOMETER

TEMPMET

Operation Temperature and Humidity :

0°C ~ 50°C, <80% RH

Storage Temperature and Humidity :

0 0-10 C ~ 60 C, <70% RH

Power Requirement :(AA Size) batteries, up to 1500 hours of continuous work time

Input Protection at Thermocouple Input :

24V AC/DC Maximum

Dimension(Without holster) :

115 mm X 70 mm x 30 mm (LxWxH)

Weight :Approx.0.25 Kg (Include Battery)

Operation Temperature and Humidity

0 00 C ~ 50 C, <80% RH

Storage Temperature and Humidity

0 0-10 C ~ 60 C, <70% RH

Power Requirement(AA Size) batteries, up to 1500 hours of continuous work time

Input Protection at Thermocouple Input :

24V AC/DC Maximum

Dimension(Without holster) :

115 mm X 70 mm x 30 mm (LxWxH)

Weight :Approx.0.25 Kg (Include Battery)

Page 33: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

THERMOGRAPHY SERVICES

Tempsens provide thermography services for various industries.

Thermography enables to monitor the thermal efficiency of

critical process systems that rely on heat transfer of retention.

This is one of the most powerful, fast and one of the most cost-

effective condition monitoring technique that has wide

application in any industry in detecting incipient faults, if left

unattended, would not only lead to loss of productivity and

quality but also increase operations and maintenance costs.

Tempsens Calibration Center is an independent unit of Tempsens instruments (I) Pvt. Ltd, having laboratories at Udaipur, Vadodara & Bangalore. It is accredited for wide range of temperature calibration services.It is the only private sector Laboratory in the country with accredited Fixed Point Temperature calibration Facilities. The lab has highly stable calibration furnaces, measuring instruments and accurate master sensors traceable to National and International Standards.

IN HOUSE CALIBRATION FACILITY

ON SITE CALIBRATION FACILITY

QualityMeasured/

Instruments

Temperature Range

Non Contact TypePyrometer

Calibration &Measurement

Capability

Contact type RTD.ThermocouplesThermometers

-25°C to 0°C>0°C to 140°C

>140°C to 250°C>250°C to 650°C

>650°C to 1200°C

0.07°C0.04°C0.09°C0.12°C1.30°C

0°C to 250°C>250°C to 500°C

>500°C to 1200°C

1.50°C2.40°C2.5°C

Multipoint Position Calibration of

Chamber, Oven, Furnaces (Thermal

Mapping(TUS))

-80°C to 200°C>200°C to 1200°C

2.8°C4.1°C

BangaloreLab

C-1226

The calibration center functions as per ISO 17025 / NABL

standards. Calibration of contact type sensors can be made in

temperature range of -196°C to 1600°C and Calibration of non

contact type sensors can be made in temperature range 0°C to

2900°C. Further the laboratory is accredited for onsite

temperature calibration.

The lab offer both at Lab & On-Site Calibration of Furnace/Bath

from -80°C to 1600°C and Black Body Calibration from 50°C to

1700°C.

Furnace/Chamber Calibration (TUS) with multiple sensors from -

80°C to 1200°C is also in the scope of the lab.

Sample Thermography Report

CALIBRATION SERVICES

FIXED POINT CALIBRATION FACILITIES

QualityMeasured/

InstrumentsTemperature Range

Calibration &

Measurement

Capability

Calibration of SPRT/PRTS/thermocouple

etc.

Triple Point of Water (0.01°C)Melting Point of Gallium (29.7646°C)

Freezing Point of Tin (231.928°C)Freezing Point of Zinc (419.527°C)

Freezing Point of Aluminum (660.323°C)

0.0038°C0.0065°C0.0065°C0.0071°C0.0075°C

Calibration ofThermocoupleat SecondaryFixed Point

Melting Point of Gold(1064.18 °C) 0.72°C

Melting Point of Palladium(1554.8 °C)

0.83°C

Contact Type RTD,ThermocouplesThermometers

Non Contact TypePyrometer

0°C to 250°C>250°C to 500°C

>500°C to 1500°C>1500°C to 1700°C>1700°C to 2900°C

1.5°C2.4°C2.5°C3.2°C4.0°C

QualityMeasured /Instruments

Temperature RangeCalibration & Measurement

Capability

-38°C to 0°C>0°C to 140°C

>140°C to 250°C>250°C to 650°C

>650°C to 1200°C>1200°C to 1600°C

-196°C -80 to -38°C

0.05°C0.03°C0.03°C0.04°C0.04°C0.12°C1.30°C2.60°C

Page 34: TTeemmppeerraattuurre e CCaalliibbrraattoor r · ¦ NABL Accredited Temperature Calibration ¦ Onsite Temperature Calibration TTeemmppeerraattuurre e CCaalliibbrraattoor r . The comparison

Tempsens Instruments (l) Pvt. Ltd. U# llA-190, Road No. 5, M.I.A., Udaipur-313003 (Rajasthan) INDIAPh. : +91-294-3052900, Fax : +91-294-3052950Email : [email protected]

INDIA GERMANY

Tempsens Instruments GmbHLoehestrasse 37,53773 Hennef, GERMANYPh. : +49 2242 8703-22, Fax : +49-2242-8703-20, Email: [email protected] [email protected]

INDONESIAPt. Tempsens Asia JayaJl. Jembatan lll Komplex F.77 No. 6CJakarta Utara14450, INDONESIAHp. : (+62)877 8080 4433Telp. : (+62) 21 666 04006Fax : (+62) 21 661 6789Email : [email protected]

THERMAL & CABLE SOLUTIONS

UAE

Tempsens Gulf Oilfield Equipment LLCUnited Arab EmiratesEmail:[email protected]