Fluke Calibration | Temperature Measurement & Calibration

Download Fluke Calibration | Temperature Measurement & Calibration

Post on 03-Feb-2015

730 views

Category:

Business

4 download

Embed Size (px)

DESCRIPTION

 

TRANSCRIPT

<ul><li> 1. Temperature Measurement and Calibration: Key Industrial Calibration Tools </li> <li> 2. Selection Guide NEW! Precision Infrared Field Metrology Wells Handheld Dry-Wells CalibratorsModel 9142/9142P 9143/9143P 9144/9144P 4180 4181 9100S 9102S 25 C to 150 33 C to 350 C 50 C to 660 CRange 15 C to 120 C 35 C to 500 C 35 C to 375 C 10 C to 122 C C 4-20 mA 4-20 mA 4-20 mABest Accuracy 0.2 C 0.2 C 0.35 C 0.35 C 0.35 C 0.25 C 0.25 CApplications Temperature transmitter, switch, and controller loop calibration Infrared thermometer and thermal imager calibration RTD Calibration Website: us.flukecal.com Call: 877.355.3225 </li> <li> 3. Fluke Calibration 9142, 9143,9144 Field Metrology Wells Features : Lightweight, portable, and fast Built-in two-channel readout for PRT, RTD,thermocouple, 4-20 mA current True reference thermometry with accuracy to 0.01 C Specifications guaranteed in an ambient range of13 C to 33 C On-board automation and documentation Website: us.flukecal.com Call: 877.355.3225 </li> <li> 4. Typical Applications Thermocouple calibration or verification Calibrations of RTDs or PRTs Testing of thermostatic switches Verification of industrial thermometers Loop calibration of temperature transmittersWebsite: us.flukecal.com Call: 877.355.3225 </li> <li> 5. Summary Specifications for9142, 9143, and 9144Website: us.flukecal.com Call: 877.355.3225 </li> <li> 6. Fluke Calibration 4180 and 4181Precision Infrared CalibratorsFeatures : Combined temperature range of -15 C to 500 C Infrared display accuracy as good as 0.35 C onboth units Convenient handle and weight of 9.5 kg (21 lbs)or less for portability Stability as good as 0.05 C over 30 minutes forboth models Uniformity as good as 0.1 C over the inner 127mm (5 in) diameter Website: us.flukecal.com Call: 877.355.3225 </li> <li> 7. Typical Applications o Infrared thermometer calibration o Thermal imager testingWebsite: us.flukecal.com Call: 877.355.3225 </li> <li> 8. Summary Specifications for4180 and 4181Website: us.flukecal.com Call: 877.355.3225 </li> <li> 9. Fluke Calibration 9100S and 9102SHandheld Dry-Well TemperatureCalibratorsFeatures : Smallest dry wells in the world Fast and easy calibrations of temperature sensors 9100S model weighs only 2 lbs, 3 oz (1 kilogram) Measure Temperature ranges from -10 C to 375 C Stability during calibrations to 0.05 C Direct interface to the Fluke 754 DocumentingProcess Calibrator Website: us.flukecal.com Call: 877.355.3225 </li> <li> 10. Typical Applications RTD calibration Thermocouple calibration Small bimetal thermometer calibrationWebsite: us.flukecal.com Call: 877.355.3225 </li> <li> 11. Summary Specifications for9100S and 9102SWebsite: us.flukecal.com Call: 877.355.3225 </li> <li> 12. Website : us.flukecal.comPhone : 877.355.3225Fax : 425.446.5116Email : info@flukecal.comAddress : 6920 Seaway Blvd, Everett, WA 98203 </li> </ul>

Recommended

View more >