THE SURGE PROTECTION SOLUTION

Unique product features and benefits never before offered in the surge protection industry

POWER QUALITY INTERNATIONAL, LLC 2404 Merchant Ave., Odessa, Florida, USA 33556 ● (888) 539-7712 ● PowerQuality.net

The Surge Protection Solution for your Critical Equipment

UL 1449 4th Edition Listed

UL 96A – Lightning Protection Master Label Compliant [1]

Dual Rated Type 1 & 2 Device

UL 20kA “In” Rating by UL*

Low VPR (clamping voltage)

Small – Perfect for Retro-Fit and New Construction

All modes protected via L-L, L-N, L-G & N-G

Available from 50kA Per Phase to 400kA Per Phase

Modular (field replaceable modules) and Compact (non-modular units)

Standard Integral Disconnect with no increase in size or cost on modular units

200kAIC Fault Current Rating

NEMA 4 Indoor or Outdoor Enclosures

Twelve Year Warranty

Additionally, the small, slim product design permits easy, clean installations, eliminating any compromising of performance as physically larger units can.

Switchboard Mounting Kit [1] except 50kA units

SPD-C100 SPD-S400

Owner
Line
Owner
Callout
TWENTY

WHAT IS AN SPD? Surge Protection Devices prevent excess electrical current (surges) from reaching devices connected beyond them. When an electrical surge is detected, the SPD diverts the excess current away from the active line directing it to ground.

HOW ARE SURGES GENERATED? Although lightning is the most spectacular form of externally generated surges, it is only one of many possible sources. Other sources include switching of power circuits, operation of electrical equipment by neighboring industries, the operation of power factor correction devices and the switching and clearing of faults on transmission lines. It is important to note that lightning does not need to directly strike a power line for damage to occur; a strike in close proximity can induce damaging surges. Additionally, it is estimated that 70-80% of all power surges are generated internal to one’s own facility, by the switching of electrical loads such as lights, heating systems, inductive motor loads and the operation of equipment.

WHY DO YOU NEED SPDS? With the statistical nature of lightning and the broad spectrum of energy delivered by a lightning flash, as well as with the problems created by various power generation/ distribution systems and the continued trend toward more sensitive and specialized electronics, facilities are increasingly required to protect equipment and sensitive loads against power surges.

WHERE TO APPLY SPD’S? UL 1449-Ed. 4 separates permanently connected SPDs into two categories: Type 1 & Type 2. IEEE C62.41 separates facility locations into three categories: A, B & C. IEEE recommends that when designing a power protection system, a cascading scheme be implemented with the appropriate devices coordinated to the locations with sensitive loads throughout the facility. The service entrance is the main entry point for lightning or utility generated surges. In general, it is where the highest surge current rated devices are located. IEEE category C - UL Type 1 or Type 2 devices are applicable in the service entrance location. The distribution/branch panels protect from residual power surges not captured by the service entrance protection and additionally protect against internally generated power surges. IEEE category B – UL Type 2 devices are applicable in the distribution/branch panel locations. Because of the impedance in the wire, ALWAYS ensure the SPD is connected with the shortest and straightest lead length possible.

SELECTING THE RIGHT SURGE PROTECTION DEVICE:

Safety Listing – UL 1449-4th Ed.

Location Rating – Type 1 (line side of MDP) or Type 2 (load side of MDP) & Distribution Panels

Performance – VPR, (Voltage Protection Rating- clamping voltage)

UL 1449 4th Ed. – Nominal Discharge Current Rating (In): Highest In rating is 20kA.

LPS Compliant – To obtain UL 96A Master Labeling of the Lightning Protection System, UL 96A requires SPDs be installed on all Service Entrance locations and be listed as Type 1 or Type 2 with a UL 1449 20kA “In” rating

Surge Rating – The manufacturer’s surge current rating is the SPD’s ability to withstand transients rated per phase and per mode based on the internal protective components

Modular Design (serviceability) – Allows for field serviceable modules

Compact (non-modular design) – Complete product replacement in the event of failure

Connection Method – Breaker connected recommended.

Enclosure Rating – Indoor (NEMA 1), Outdoor (NEMA 4), or Corrosive (NEMA 4X) are the typical enclosure ratings for SPDs

Physical Mounting Options – Side/Bottom of Panel, Flush Mounted (dry wall), Switchboard Top Mounting

AIC Rating – Per NEC 285-6 the SPD must be rated equal to or greater than the point of connection on the electrical system

Monitoring Features – Visual indication of power and proper operation, Remote Alarm Contacts and a Surge Event Counter are some options offered with SPDs

Warranty – Industry Standard is Twelve (12) Years Unlimited Replacement

SPD Dimensions – Most electrical rooms are small. Keeping the connected wire length short means having an SPD that will physically fit in the space allocated without sacrificing the SPD performance rating with long connection wires.

SPD-LA SURGE PROTECTION DEVICE

SPD-C50 SURGE PROTECTION DEVICE

SPD-C100 SURGE PROTECTION DEVICE SPD-C200 SURGE PROTECTION DEVICE

SPD-M100 SURGE PROTECTION DEVICE

SPD-M200 SURGE PROTECTION DEVICE

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 20kA per mode; 40kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Compact, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 12AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 10kA (In) Maximum Surge Current Rating: 25kA per mode; 50kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Compact, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 10AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 50kA per mode; 100kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Compact, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 10AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 20kA per mode; 40kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Compact, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 12AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 50kA per mode; 100kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Modular per mode/phase, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 10AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 100kA per mode; 200kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Modular per mode/phase, thermal protected MOV’s Connection Method: Parallel, supplied with 36” 10AWG leads

Recommended Breaker Size: 20Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Blue LED Indicator Enclosure Type: NEMA 4X, UL 50 Installation Location: Indoor or Outdoor Enclosure Material: UV-Stabilized Thermoplastic Weight: 1.0 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Indication per phase & Remote Alarm Contacts Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 2.0 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Indication per phase & Remote Alarm Contacts Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 2.2 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Indication per phase & Remote Alarm Contacts Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 4.5 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Audible Alarm, Redundant Indication per phase and per mode, Remote Alarm Contacts Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 4.4 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Audible Alarm, Redundant Indication per phase and per mode, Remote Alarm Contacts Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 6.2 lbs.

SPD-S300 SURGE PROTECTION DEVICE

SPD-S400 SURGE PROTECTION DEVICE

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 150kA per mode; 300kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Modular per mode/phase, thermal protected MOVs Connection Method: Parallel, supplied with 36” 10AWG leads

Safety Listings: UL® 1449 4th Edition UL® 1449 - Ed. 4 Location Rating: Type 1 and Type 2 IEEE® C62.41 Location Rating: Category C- High & Category B- Medium Nominal Discharge Current Rating: 20kA (In) Maximum Surge Current Rating: 200kA per mode; 400kA per phase Fault Current (SCCR): 200kAIC MCOV Minimum 115%. Details listed on Spec Sheet. Product Design: Modular per mode/phase, thermal protected MOVs Connection Method: Parallel, supplied with 36” 10AWG leads

SPD-M100

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Audible Alarm, Redundant Indication per phase and per mode, Remote Alarm Contacts;

Surge Counter Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 13 lbs.

Recommended Breaker Size: 30Amp Protective Components: Thermal MOVs and AIC Fusing Response Time: < 1 Nanosecond Frequency: 50/60Hz Status Indicators: Audible Alarm, Redundant Indication per phase and per mode, Remote Alarm Contacts; Surge Counter Enclosure Type: NEMA 4, pending UL Type 4 Installation Location: Indoor or Outdoor Enclosure Material: Metal (powder coated aluminum) Weight: 13 lbs.

SPD-C200

VPR L- N L- L L- G N- G SPD-LA VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 900 1000 600 120/208 120/208, 3 phase, 4W + ground 800 1000 1800 600 277/480 277/480, 3 phase, 4W + ground 1500 1800 2500 1200 120/120, 1 phase, 2W + ground 1800 1000 900 600

Model number example: PQLA120/240

SPD-C50 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 600 1000 700 600 120/208 120/208, 3 phase, 4W + ground 600 1000 700 600 277/480 277/480, 3 phase, 4W + ground 1200 1800 1200 1200 120/240D 120/240D, 3 phase hi-leg delta 1200 1800 1200 1200

Model number example: PQC50120/240

SPD-C100 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 600 1000 600 600 120/208 120/208, 3 phase, 4W + ground 600 1000 600 600 277/480 277/480, 3 phase, 4W + ground 1000 1800 1200 1200 120/240D 120/240D, 3 phase hi-leg delta 1000 1800 1200 1200

Model number example: PQC100120/240

SPD-C200 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 800 1500 800 600 120/208 120/208, 3 phase, 4W + ground 800 1500 800 600 277/480 277/480, 3 phase, 4W + ground 1200 1800 1200 1000 120/240D 120/240D, 3 phase hi-leg delta 1200 1800 1200 1000

Model number example: PQC200120/240

SPD-M100 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 600 1000 700 600 120/208 120/208, 3 phase, 4W + ground 600 1000 700 600 277/480 277/480, 3 phase, 4W + ground 1200 1800 1200 1200 240D* 240, Delta 3W + ground (no neutral) 1200 1800 1200 1200 120/240D 120/240, 3 phase, hi-leg delta 600 1000 700 600 480D* 480V Delta 3W + ground (no neutral) 600 1000 700 600

Model number example: PQM100120/240 *Indicates models ETL listed

SPD-M200 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 600 1000 600 600 120/208 120/208, 3 phase, 4W + ground 600 1000 600 600 277/480 277/480, 3 phase, 4W + ground 1000 1800 1200 1200 240D 240, Delta 3W + ground (no neutral) 1000 1000 120/240D 120/240, 3 phase, hi-leg delta 1000 1800 1200 1200 480D 480V Delta 3W + ground (no neutral) 1800 1800

Model number example: PQM100120/240 *Indicates models ETL listed

SPD-S300 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 800 1200 800 700 120/208 120/208, 3 phase, 4W + ground 800 1200 800 700 277/480 277/480, 3 phase, 4W + ground 1200 1800 1200 1000 120/240D 120/240, 3 phase hi-leg delta 1200 1800 1200 1000

Model number example: PQS300120/240

SPD-S400 VOLTAGE CONFIGURATIONS 120/240 120/240, 1 phase, 3W + ground 800 1200 800 700 120/208 120/208, 3 phase, 4W + ground 800 1200 800 700 277/480 277/480, 3 phase, 4W + ground 1200 1800 1200 1000 120/240D 120/240, 3 phase hi-leg delta 1200 1800 1200 1000

Model number example: PQS400120/240

SPD-LA OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM

SPD-C50 OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM

SPD-C100 OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM

SPD-C200 OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM

SPD-M100 OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM Surge Counter & Filtering Option: Replace “M” with “S”, e.g. PQI-M100-(Voltage) Replacement Module(s): PQI-M100-MOD Replacement Fuse(s): PQI-FUSE Switchboard Top Mount Kit: STMK100

SPD-M200 OPTIONS Flush Mounting Kit: FM Side Mount Kit: SM Surge Counter & Filtering Option: Replace “M” with “S”, e.g. PQI-M100-(Voltage) Replacement Module(s): PQI-M100-MOD Replacement Fuse(s): PQI-FUSE Switchboard Top Mount Kit: STMK100

SPD-S300 OPTIONS Side Mount Kit: PQSM Replacement Module(s): PQS300-MOD Replacement Fuse(s): PQFUSE Switchboard Top Mount Kit: STMK300

SPD-S400 OPTIONS Side Mount Kit: PQSM Replacement Module(s): PQS300-MOD Replacement Fuse(s): PQFUSE Switchboard Top Mount Kit: STMK300