surge voltage protection

Upload: rajpre1213

Post on 04-Jun-2018

242 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 Surge Voltage Protection

    1/22

    SURGE VOLTAGE PROTECTION

    419

    SURGE ARRESTER SETS: QUICK SELECTION420

    PROTEC SURGE ARRESTERS, CLASS B/C422

    COMBTEC SURGE ARRESTERS, CLASS B/C424

    SPARK GAP BASED SURGE ARRESTERS, CLASS B

    426

    VARTEC SURGE ARRESTERS, CLASS C429

    SURGE ARRESTERS, CLASS C432

    SURGE ARRESTERS, CLASS D434

    ARRESTER DISCONNECTOR SWITCH, INDUCTIVE DECOUPLING439

    419

    419

  • 8/14/2019 Surge Voltage Protection

    2/22

    Switches with relay contact usually have a 1 at the end of the article number, e.g. IS 110331

    PGR 4950W TN-C SYSTEM, PROTECTIVE ACTION:TN SYSTEM (PEN CONDUCTOR)

    W When choosing a surge arrester:

    Consider the detailed requirements in the following diagram and then select the appro-

    priate switch type and surge arrester in the next section as appropriate to the mainssystem and protective action required.

    PGR 4950W SURGE ARRESTER SETS: QUICK SELECTION

    SURGE ARRESTER SETS: QUICK SELECTION

    20

    uebspset.eps

    uebspg_d.eps

    tnc.eps

    W SELECTING THE SWITCH TYPE, FINDING THE CORRECT ORDER NUMBERS 3)

    tn_c_set.eps

    COLOUR CODE LIGHTNING PROTECTION CL. DESCRIPT ION TYPE I IM P / IN UC ORDER NO.

    I, I I B/C surge arres ter Protec TN-C-Set 25 kA (10/350) 335 V IS110330

    I I I, (IV) B/C surge arres ter CombtecTN-C-Set 12.5 kA (10/350) 335 V IS110230

    C surge arrre s te r Var tec TN-C-Se t 15 kA (8/20) 335 V IS110130

  • 8/14/2019 Surge Voltage Protection

    3/22

    SURGE ARRESTER SETS: QUICK SELECTION

    421

    PGR 4950W TT SYSTEM, PROTECTIVE ACTION:RCCB PROTECTION 2)

    Colour code Lightning protection Cl. Descr. Type imp / In Uc Order no.

    I , I I B/C surge arrester Protec TN-S-Set 25 kA (10/350) 335V IS110340

    III , ( IV) B/C surge arrester CombtecTN-S-Set 12.5 kA (10/350) 335V IS110240

    C surge arres ter Vart ec TN -S -S et 15 kA (8 /2 0) 33 5V IS 11 01 40

    W TIPS & TRICKSTip: No surge arrester is required for the Neutral conductor and the TN-C-SET can be used If the PEN conductor (protec-

    tive multiple earthing connection) was separated in the immediate vicinity, e.g.in the upstream meter section.

    Switches with relay contact usually have a 1 at the end of the article number, e.g. IS 110341

    PGR 4950W TN-S SYSTEM, PROTECTIVE ACTION:TN SYSTEM (PEN CONDUCTOR SPLIT INTO PE & N)

    tns.eps

    tn_s_set.eps

    tt_set.eps

    tt.eps

    Colour code Ligh tn ing protec tn.C l Descrip tion Type Iim p / In Uc1) Order no.

    I , I I B/C conduc tor Protec TT-Set 25 kA (10/350) 335 V IS110310

    III, (IV) B/C conduc tor Combtec TT-Set 12.5 kA (10/350) 335 V IS110210

    C surge arrester Var te c TT- Se t 15 kA (8 /2 0) 33 5 V IS110110

    W

    NOTEThis 3+1 switching operation can also be used in the TN-S and in IT networks. The N/PE surge arrester meets all stan-dard requirements with 100kA(10/350) for BSK I,II, and 50kA(10/350) for BSK III, IV, as well as 20kA(8/20) for the C

    surge voltage protection.

    Switches with relay contact usually have a 1 at the end of the article number, e.g. IS 110311

    1) Except for N/PE conductors in 3+1 switching operation (> 255V)2) Switching variants with the ISP have been ommitted here for reasons of clarity.3) Sets are delivered as separate and are not pre-assembled. We would be happy to supply more detailed information about

    these sets and how they can interconnect where necessary.

  • 8/14/2019 Surge Voltage Protection

    4/22

    BV 25-275/335 BVR 25-275/335 BG100*

    Varistor N/PE Gas surge arrester

    Continuous voltage Uc 275/335 VAC 255 VAC

    Nominal discharge current ln (8/20s) 40 kA 100 kA

    Max. discharge current lmax (8/20s) 100 kA 150 kA

    Lightning impulse current Iimp (10/350s) 25 kA 100 kA

    Protection level Up at In 1600 V

    Protection level Up bei Iimp 1250 V

    Protection level Up (gas surge arrester)-(1,2/50s) 1200 kV

    Response time ta < 25 ns < 100 ns

    Max. permissible ambient temperature -40 C up to +80 C

    Degree of protection open/installed IP 20/40

    Max. permisible fuse: 250 AgL

    Short-circuit protection with max. fuse 25 kA / 50 Hz

    Enclosure material Thermoplastic, self-extinguishing

    Max. terminal cross section 25/35 mm2

    DIN-rail mountable both sides, top terminals for V wiring

    Model with auxiliary contact BVR 25-275/335

    Auxillary contacts 250 V AC/0,5 A, max. 1,5 mm2

    PGR 4955W SURGE ARRESTER B (B/C), PROTEC 25 kA SERIES

    PROTEC SURGE ARRESTERS, CLASS B/C

    22

    protec_bgf.ep sis010091.eps

    bvr25_s.eps

    bv_m.eps

    bv25_s.eps bg100_s.eps

    W TECHNICAL DATASurge arrester class B/C,

    Class I/II, Type of design 1/2,

    meets EN/IEC-SN 60, part 4,and EN/IEC 61643

    *) In preparation: replacement type IS010094, can only be used as a N-/PE conductor in a 3+1 switching operation

  • 8/14/2019 Surge Voltage Protection

    5/22

    PROTEC SURGE ARRESTERS, CLASS B/C

    423

    uebsp_b3.eps

    tt1.eps

    tns1.eps

    tnc1.eps

    W TIPS & TRICKSNational regulations for installation must be followed!

    In Austria: EN/IEC 8001-1, EN/IEC E 8049. or IEC

    60364-5-53 A1.

    W RANGE OF A PPLICATIONVaristor-lightning arresters/surge arresters designed for

    indoor mounting as a means of protecting consumer

    appliances against lightning and transient voltage sur-

    ges. Can be used for construction systems with I and II

    classes of protection in accordance with EN/IEC E 8049.

    The surge arrester operates in any position.

    The application of varistor technology extinguishes

    mains follow currents. It also ensures that connected

    devices are stress free and also offers a lower protec-

    tion set off. No additional gas-filled blow-out sparkgaps are required.

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Protec BV 25 kA EN/IEC 1) 35x90x64 6 BV 25/335 0,296 IS010091

    Protec BV 25 kA +H EN/IEC 1) 35x90x64 6 BVR 25/335 0,306 IS010095

    Protec BV 25 kA IEC 2) 35x90x64 6 BV 25/275 0,296 IS010191

    Protec BV 25 kA +H IEC 2) 35x90x64 6 BVR 25/275 0,306 IS010195

    CU-Busbar, 3x f. TN-C network - 50 PES 3x2 - IS010173

    CU-Busbar,, 4x f. TN-S TT network - 50 PES 4x2 - IS010174

    1) EN/IEC design according to VE/NORM 8001-1, section18. Must be implemented by law in Austria.2) Export model- must not be implemented in Austria.

    Also see SET - article, page 400, 410.

  • 8/14/2019 Surge Voltage Protection

    6/22

    VV 275/335* VS275/335*Varistor Varistor

    Continuous voltage Uc 275/335 VAC 275 / 335 V AC

    Nominal discharge current ln (8/20s) 40/40 kA 40 kA

    Max. discharge current lmax (820s) 80/80 kA 80 kA

    Lightning impulse current Iimp (10/350s) 12.5/12.5 kA 12.5 kA

    Protection level Up at In 1,8/1,8 kV 1,8 kV

    Protection level Up at I imp 1,2/1,2 kV 1,2 kV

    Response time ta < 25/< 25 ns < 25 ns

    Max. permissible ambient temperature -40 C up to +80 C

    Degree of protection open/installed IP 20/40Max. permisible fuse: 250 AgL

    Short-circuit protection with max. fuse 25 kA/50Hz 25 kA/50Hz

    Enclosure material Thermoplastic, self-extinguishing V0

    Max. terminal cross section 25/35 mm2

    DIN-rail mountable on both sides

    Model with auxiliary contact VVR 335 VSR 335

    Auxillary contacts 250 V AC/0,5 A, max. 1,5 mm2

    PGR 4955W SURGE ARRESTER CLASS B/C, COMBTEC SERIES, 12,5 kA

    COMBTEC SURGE ARRESTERS, CLASS B/C

    24

    vvr25_s.eps

    is010083.epsis010081.eps

    bv_m.eps

    vv_s.eps vs_s.eps

    W TECHNICAL DATAFor each path: Class B/C, type of design I/II, type 1/2, EN/IEC-SN 60, part 4, / EN/IEC 61643

    approved

    vv25_s.eps vs335_s.eps

    vsr335_s.eps

    *) Use N/PE surge arrester IS010084

    when using the 3+1 switching operation.

  • 8/14/2019 Surge Voltage Protection

    7/22

    COMBTEC SURGE ARRESTERS, CLASS B/C

    425

    W TIPS & TRICKSNational regulation for installation must be followed!

    In Austria: VE/NORM 8001, VE/NORM E 8049.

    or IEC 60364-5-53 A1.

    W RANGE OF A PPLICATIONCombined lightning arresters/surge arresters designed

    for indoor mounting as a means of protecting

    consumer appliances against lightning and transient

    surge voltages. Are ideally used for construction

    systems having protection class III and (IV) according to

    VE/NORM E 8049. Surge arrester operates in all

    locations. Coupling VV-SG50-VS surge arresters provide

    a low protection level in a variety of network systems

    (TT/IT/TN-C/TN-C-S) with the width of an RCCB of only

    4 MW (3+1 switching operation 6 MW) without any

    mains follow currents.

    vv_tnc_s.epsvv_tn_s.eps

    vv_31_s.eps

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Combtec VV 12,5 kA VE 1) 35x90x64 6 VV 335 0,296 IS010081

    Combtec VS 12,5 kA IEC 2) 35x90x64 6 VS 275 0,226 IS010183

    Combtec VVR 12,5 kA + H IEC 2) 35x90x64 6 VVR 275 0,306 IS010185

    Combtec VSR 12,5 kA+H VE 1) 35x90x64 6 VSR 335 0,236 IS010087

    Combtec VV 12,5 kA IEC 2) 35x90x64 6 VV 275 0,296 IS010181

    Combtec VS 12,5 kA VE 1) 35x90x64 6 VS 335 0,226 IS010083

    Combtec VVR 12,5 kA+H VE 1) 35x90x64 6 VVR 335 0,306 IS010085

    Combtec VSR 12,5 kA+H IEC 2) 35x90x64 6 VSR 275 0,236 IS010187

    CU-Busbar, 2x f. TN-C network 35x90x64 50 PES 2x2 - IS010172

    Lighting arrester N/PE-50 kA, SG50 35x90x64 6 SG50 0,226 IS010084

    CU-Busbar, 3x f. TN-C network - 50 PES 3x2 - IS010173

    CU-Busbar, 4x f. TN-S TT network - 50 PES 4x2 - IS010174

    Also see SET - article, page 400, 401.

    1) VE/NORM design according to VE/NORM 8001-1, section18. Must be implemented by law in Austria.2) Export model must not be implemented in Austria.

  • 8/14/2019 Surge Voltage Protection

    8/22

    35

    45

    50

    64

    90

    W TECHNICAL DATA Level of protection < 2,5 kV

    No blow-out opening, hence no need for spark gaps

    Optional relay contact

    Test current 25 kA, 60 kA (10/350s)

    High Insulation resistance Risol > 1010

    Rated voltage Uc: 335 V~

    Nominal operating voltage Un: 230 / 400 V AC 50/60 Hz

    Response time < 50 ns

    Max. permissible conductor/back-up fuse F2

    with single drop 160 A gL

    Max. permissible conductor/back-up fuse F3

    with V-wiring: 100 A gL

    Operating temperature range: -40 C up to +85 C

    Max. cable cross-section:

    multi-wired 50 mm2/ fine-wired 35 mm2

    Enclosure material / colour:Polycarbonate (halogen-free)/ grey RAL 7035

    Degree of protection: IP 20

    Mounted on DIN-rail 35 mm accord. to EN 50 022

    W CERTIFICATIONStested in accordance with E DIN VDE 0675-6-11/98-A1 and EN

    61643-11 /IEC 61643-1and VE 8001-1.

    Classification accord. to class B/C, I + II, T1, T2

    W PRODUCT DESCRIPTION:POWERTEC 25, 60 (R) with a low protection level is a selective,

    two-level T1 + T2 (B+C) surge arrester, which combines protection

    classes I+II in a single device. This means no decoupling elements

    are required for cable lengths under 10 m. Using hermetically sea-

    led spark gaps filled with inert gas means that the requirement of a

    high discharge capacity is fulfilled while maintaining functional stability.

    The first level (non-linear resistor type arrester) discharges impact

    currents (up to 4kA) without causing any mains follow-currents.

    When a pre-defined impact current (up to 4 kA) has been ex-

    ceeded, the second level (the hermetically sealed spark gap filled

    with inert gas) engages for the less common discharge of high-

    energy transients up to 25 kA / 60 kA (10/350 s) which may arise

    during close-up or direct lightning strikes. As an option, a potential-

    free relay contact (R) with terminal is included in the enclosure- to

    aid signalising.

    V-wiring can be easily installed using the unlabelled terminal

    (the one not connected with the L/N terminal in the device)

    using the optional 2-pole comb-type rail.

    PGR 4952W LIGHTNING ARRESTER 25 / 60 kA WITH SPARK GAP,POWERTEC SERIES

    SPARK GAP BASED SURGE ARRESTERS, CLASS B

    26

    uebsp_m2.eps

    uebsp_m1.eps

    is0101_gf.eps

    uebsp_a.eps

    DESCRIPTION DIM. (WxHxD) PU WEIGHT ORDER NO.

    Lightning arrester, 25 kA KI/II B/C 35x90x64 1 0,19 IS010111

    Lightning arrester, 25 kA+H CI/II B/C 35x90x64 1 0,19 IS010112

    Lightning arr. 60 kA KL.I/II B/C 35x90x64 1 0,19 IS010113

    Lightning arr. 60 kA+H KI/II B/C 35x90x64 1 - IS010114

    CU-Busbar, 3x f. TN-C network - 50 - IS010173

    CU-Busbar, 4x f. TN-S TT network - 50 - IS010174

  • 8/14/2019 Surge Voltage Protection

    9/22

    SPARK GAP BASED SURGE ARRESTERS, CLASS B

    427

    W TECHNICAL DATA N/PE Spark-gap based lightning arrester,

    for use in 3+1 switching operation

    No leakage current No blow-out opening, hence no need for spark gaps

    test current 50 kA / 100 kA (10/350 s)

    meeting lightning protection class III, (IV)

    High Insulation resistance Risol > 1010

    Level of protection < 1.5 kV

    High follow-current reset capability

    Multi-functional lift terminal for conductor and comb-type rail

    Nominal mains and operating voltage Un: 230 / 400 V AC 50/60 Hz

    Rated voltage Un: 225 V AC 50/60 Hz

    Response time < 50 ns

    Follow-current reset capability at Uc (50/60Hz) up to 100 Aeff / 200 Aeff Short-circuit protection with max. back up fuse 160A gL: 25 kAeff

    Operating temperature range: -40 C up to +85 C

    Max. cable cross-section:

    multi-wired 50 mm2/ fine-wired 35 mm2

    Enclosure material / colour: Polycarbonate (halogen-free)/ grey RAL 7035

    Degree of protection: IP 20

    Mounted on top-hat rail 35mm accord. to EN 50022

    W CERTIFICATIONSTest in accordance with EN 61643-11 & IEC 61643-1,

    VE 8001-1

    W RANGE OF A PPLICATIONSG50 used in combination with COMBTEC VV, VS, G100 in combination with

    PROTEC, POWERTEC in 3 + 1 switching operation is used to protect against

    direct lightning strikes in external overhead lines or external lightning arrester

    in the TT system. See graphic for application.

    W PRODUCT DESCRIPTION:SG 50, G 100 are 1-pole N/PE lightning arresters with protection class I+II+III

    (B+C+D) for protection against partial lightning currents from entering elec-

    trical installations. The device is used for equipotential bonding of lightning

    protection in the 400/230 VAC TT system, as a N/PE conductor with 3 + 1

    switching operation.

    It is able to deflect lightning currents up to 50 kA / 100 kA (10/350 s) with

    a charge of 50 As, and has a low protection level, Up < 1,5 kV.

    The use of a hermetically-sealed high-performance spark-gap filled with inert

    gas makes use of a dangerous blow-out opening superfluous.

    W INSTALLATION- AND OPERATING NOTES:A gap need no longer be enforced between neighbouring cables and compo-

    nents to prevent arcing faults. Given that this arrester is required to deflect

    high lightning currents, we recommend the use of single-wire Cu conductors

    upwards of 16 mm2. The entire length of the connectiosn must not exceed0.5 m. If this cannot be ensured, install the PE conductor with an extra terminal

    V-formed where possible.

    PGR 4952W N/PE LIGHTNING ARRESTER, 50 kA /100 kA (10/350) S, SG50, G100

    is0100_gf.eps

    35

    45

    5064

    90

    uebsp_m2.eps

    uebsp_b4.eps

    uebsp_b1.eps

    uebsp_b2.eps

  • 8/14/2019 Surge Voltage Protection

    10/22

    SPARK GAP BASED SURGE ARRESTERS, CLASS B

    28

    W CAUTION:The SG 50, G 100 must only be installed by specialist electricians. All valid norms must be observed during mounting

    and installation. This device must only be used as a N/PE aggregate-lightning arrester in the 3+1 switching operation,

    appropriate to the lightning protection class.

    W FAULT DETECTIONWhen required, this arrester can also be tested using an insulation meter. When Risol 0.5 to 1 M, the arrester must

    be replaced at the next opportunity, when Risol < 0.5 M it must be replaced immediately.

    DESCRIPTION DIM. (WxHxD) PU WEIGHT ORDER NO.

    N/PE lightning arrester, 50 kA, SG50, 35x90x64 6 0,226 IS010084

    N/PE lightning arrester, 100kA G100 35x90x64 1 0,19 IS010094

    CU-Busbar, 4x f. TN-S TT network - 50 - IS010174

  • 8/14/2019 Surge Voltage Protection

    11/22

    VARTEC SURGE ARRESTERS, CLASS C

    429

    VVP 255 VVP 335 DVP 255 2)

    Varistor Varistor Gas-filled surge arresterContinuous voltage Uc 255 VAC 335 VAC 255 VAC

    Nominal discharge current ln (8/20s) 15 kA/20 kA 15 kA/20 kA 20 kA

    Max. discharge current lmax (8/20s) 30 kA/40 (30) kA 30 kA/40 (30) kA 40 kA

    Protection level Up at In 1,3/1.4 kV 1,4 kV/1,65 kV 1 ,2 kV

    Response time ta < 25 ns < 25 ns < 100 ns

    Max. permissible ambient temperature -40 C up to +80 C

    Degree of protection open/installed IP 20/40

    Max. permisible fuse: 100 A 100 A

    Max. terminal cross section 16/25 mm2

    Auxiliary contact (optional) 250 V AC/0,5 A, max. 1,5 mm2

    DIN-rail mountable on both sidesMax. terminal torque 2,5 - 3,0 Nm (main terminal)

    W PLUG-IN SURGE ARRESTER, VARTEC VVP, DVP SERIES

    7n5b4994.eps7n5b4992.eps

    7n5b4990.eps7n5b4976.eps

    W TECHNICAL DATAClass C, design type II, type 2,

    meets VE-SN 60, part 4 & EN/IEC 61643

    65

    8045

    17,5vvp_m.eps

    VPP 255/355

    vpp_s.eps

    DVP 255

    dvp255_1.eps

    vpp_h_s.eps dvp255_2.eps

  • 8/14/2019 Surge Voltage Protection

    12/22

    VARTEC SURGE ARRESTERS, CLASS C

    30

    tn_s_s.eps tn_cs_s.eps

    tn_c_s.eps

    WTIPS & TRICKSObserve the respective national regulation for installation! E.g. VE 8001-1 or

    IEC 60361-5-53 A1. The neutral contactor does not require a surge protection device (in accordance with the TN-C

    switching arrangement) if the protective multiple earthing connection is set up where the surge protection device is

    integrated.

    The connection line to the equipotential bonding rail or PE rail should be as short as possible and without looping. All

    surge devices must be unplugged during insulation measurement.

    The VVP335 surge arrester has been designed for mains voltages of 3~400/230 V in accordance with VE 8001-1.

    According to IEC 603645-5-53 A1, the VVP255 surge arrester is for export only.

    WRANGE OF APPLICATIONPlug-in surge arresters designed for indoor mounting as a means of protecting consumer appliances against lightning

    and transient voltage surges The surge arrester operates in any position. Terminal assignment for the mains and

    PE/PEN- conductor is freely definable.

    Also see SET - article, page 420, 421.

    1)VE design according to VE 8001-1, section18. Must be implemented by law in Austria.2

    )Export model must not be implemented in Austria.3) As specified in NORM/VE E8001-1, the 20kA requirement still applies to the surge arrester between Neutral and the

    main earthing rail (N/PE conductor). (PAS) or PE-rail, even in cases where surge protection devices were installed with

    greater nominal discharge currents, e.g. 15 kA or 20 kA between the external conductors and the Neutral conductor.

    DESCRIPTION PU TYPE ORDER NO.

    C-arrester module 15 kA VE VVP335 1) 12 VVP335-15 IS010078

    C-arrester module 20 kA VE VVP335 1) 12 VVP335-20 IS010079

    C-arrester module 15 kA IEC VVP255 2) 12 VVP255-15 IS010076

    C-arrester module 20 kA IEC VVP255 2) 12 VVP225-20 IS010077

    N-PE surge arrester Module 20kA DVP255 3) 12 DVP255 IS010075

    Base,1-pol. for VVP 12 VPS/1 IS010071-A

    Base,1-pol. for VVP +H 12 VPSH/1 IS010069-A

    Base,1-pol. for DVP 12 DPS/1 IS010070-A

    Base,1-pol. for DVP +H 12 DPSH/1 IS010068-A

    Base 3+1 operation 3 VPS/3+1 IS010064-A

    Base 3+1 operation +H 3 VPSH/3+1 IS010065-A

    Busbar, 3x, insulated, for TN-C system 10 VII-3 IS050103

    Busbar, 4x, insulated, for TN-S, TT system 10 VII-4 IS050104

    Busbar, 5x, insulated, for N arrangement 10 VII-5 IS050105

  • 8/14/2019 Surge Voltage Protection

    13/22

    VARTEC SURGE ARRESTERS, CLASS C

    431

    VEPG

    Varistor + gas surge arrester

    Continuous voltage Uc 335 VAC Nominal discharge current ln (8/20s) 10 kA / Pol

    Imax (8/20s) 20 kA / Pol

    Level of protection Up at In 1,6 kV at 5 kA 950 V

    Response time ta < 100 ns

    Max. permissible ambient temperature -40 C up to +80 C

    Degree of protection open/installed IP 20/40

    Max. permisible fuse: 100 A

    Max. terminal cross section L, N = 6 mm2; PE = 25/35 mm2

    Auxiliary contact (optional) 250 VAC / 0,5 A; max. 1,5 mm2

    WVARTEC SURGE ARRESTER CLASS C, VEPG SERIESFOR SINGLE-PHASE OPERATION, 230 VAC, 1 MODUL WIDE

    65

    9045

    17,5var_s2.eps

    var_s1.epsis010073.eps

    vepg_m.eps

    W TECHNICAL DATAClass C, design type II, type 2,

    meets VE 60, part 4 & EN/IEC 61643

    W TIPS & TRICKS

    Space saving - only 1 module wide

    Ideal for retrofits (renovating old buildings)

    D surge arrester, protection level (Up 950 V at

    5 kA In (8/20)

    High back-up fuse possible

    National regulations for installation must be

    followed!

    W RANGE OF A PPLICATION

    Surge arresters designed for indoor mounting as ameans of protecting consumer appliances against light-

    ning and transient voltage surges The surge arrester

    operates in any position.

    The connection line to the equipotential bonding rail

    or PE rail should be as short as possible and without

    looping.

    When measuring insulation, the surge arrester is

    disconnected from PE by the gas-filled spark gap.

    DESCRIPTION DIM. (WxHxD) PU ORDER NO.

    C surge arrester, 10 kA, 335 V, 1-phase, 1 modul wide 17,5x90x65 1 IS010073

    Base for VMG / VEPG - 12 IS010201

    Base + H for VMG / VEPG - 12 IS010202

  • 8/14/2019 Surge Voltage Protection

    14/22

    17,5

    61,5

    44

    80 45

    5,5

    W TECHNICAL DATATest class II following IEC 61 643

    Surge arrester class C in accordance with VE-SN 60

    part 1/part 4

    Design type with ZnO varistor II Width 1 modul wide per pole

    Rated voltage UB (50 Hz) 280 V, 335 V, 460 V

    Max. permissible back-up fuse 160A

    Rated discharge current ISN (8/20) s 20 kA (10 kA)

    Charge Q at ISN 0,43 As

    Specific energy at ISN 3,2 kJ/

    Max. discharge current ISG 40 kA

    Response time (RRV 5 kV/s) < 25 ns

    Level of protection at ISN < 1,4 kV

    Max. permissible short-circuit current 10 kA

    Temperature range -40 C to +70 C Degree of protection (integrated) IP 40

    Gap terminals above and below

    for conductor cross-section 4 - 25 mm2

    Claw-type terminal top and bottom for rails

    up to 1,5 mm in strength

    Quick-fastening onto rail in accordance with EN 50022

    Relay contact UAS-FM can be retrofitted,

    1 C/O

    Fits RCCB and MCB rails

    Other voltages upon request

    W TIPS & TRICKSObserve the rated voltage when choosing a surge arrester.

    When using surge arresters in Austria, select according to

    the binding regulation VE 8001-1, Pt. 18 Uc 335 V.

    W CERTIFICATIONSVE

    W RANGE OF APPLICATIONTo protect consumer units against transient surge voltages

    caused by indirect lightning strikes and switch operations.

    PGR 4953W PLUG-IN SURGE ARRESTER

    SURGE ARRESTERS, CLASS C

    32

    is010045.eps

    is01_xx.eps

    is01_46s.eps

    is01_46m.eps

    is01_41s.eps

    is01_25s.eps

    is01_23s.eps

  • 8/14/2019 Surge Voltage Protection

    15/22

    SURGE ARRESTERS, CLASS C

    433

    1) VE design according to VE 8001-1, section18. Must be implemented by law in Austria.

    2) Export model- must not be implemented in Austria.

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Varistor insert, 20 kA, for export, 280 V 2) 17,5x52x60 4 UAS 20/280 0,065 IS010045-A

    Varistor insert, 20 kA, 335 V EN/IEC 1) 17,5x52x60 4 UAS 20/335 - IS010052-A

    Varistor insert, 20 kA, 460 V EN/IEC 1) 17,5x52x60 4 UAS 20/460 - IS010051-A

    N/PE conductor, 20 kA, 260 V EN/IEC, onlyavailable for 3+1 switching operation 17,5x52x60 4 UAS-N/PE - IS010053

    Base, 1-pole (coded for N/PE conductor) 17,5x80x49,5 12 UAS/U1 0,048 IS010046

    Base, 2-pole (coded for N/PE conductor) 35x80x49,5 6 UAS/U2 0,1 IS010047

    Base, 3-pole (coded for N/PE conductor) 52,5x80x49,5 4 UAS/U3 0,148 IS010048

    Base, 4-pole (coded for N/PE conductor) 70x80x49,5 3 UAS/U4 0,2 IS010049

    Base 3+1 operation 70x90x49,5 3 UAS /3+1 0,2 IS010054

    Plus relay contact, 1 C/O - 8 UAS-FM - IS010044

    Rail, 2x, insulated - 10 VII -2 - IS050102

    Busbar, 3x, insulated, for TN-C system - 10 VII -3 - IS050103

    Busbar, 4x, insulated, for TN-S, TT system - 10 VII -4 - IS050104

    Busbar, 5x, insulated, for N arrangement - 10 VII -5 - IS050105

  • 8/14/2019 Surge Voltage Protection

    16/22

    VMG 275

    Varistor + gas surge arrester

    Continuous voltage Uc 275 VAC

    Nominal discharge current ln (8/20s) 3 kA / Pol

    Uoc (1,2/50) 6 kV / Pol

    Protection level Up at In 0.9 V

    Response time ta < 100ns

    Max. permissible ambient temperature -40 C up to +80 C

    Degree of protection open/installed IP 20/40

    Max. permisible fuse: 63 A Max. terminal cross section L, N = 6 mm2; PE = 25/35 mm2

    Auxiliary contact (optional) 250 VAC / 0,5 A; max. 1,5 mm2

    DIN-rail mountable on both sides

    W PLUG-IN SURGE ARRESTER, D CLASS,VMG SERIES FOR SINGLE PHASE OPERATION, 230 V, 1 MODUL WIDE

    PGR 4954W LOW-LEVEL SURGE VOLTAGE PROTECTION, DIN-RAIL

    SURGE ARRESTERS, CLASS D

    34

    var_s1.eps

    is010201gf.eps is010201.eps

    is010200.eps

    is0102_s.eps

    W

    TECHNICAL DATAClass D, design type II, type 2,meets VE-SN 60, part 4 & EN/IEC 61643

    W TIPS & TRICKS National regulations for

    installation must be followed!

    Space saving - only 1 module wide

    Plug-in module

    N/PE - spark gap already fitted

    Low level of protection

    High back-up fuse possible

    W RANGE OF APPLICATIOND class surge arresters designed for indoor mounting as

    a means of protecting consumer appliances against

    lightning and transient voltage surges. The surge

    arrester operates in any position.

    The connection line to the equipotential bonding rail

    or PE rail should be as short and possible and without

    looping.

    When measuring insulation, the surge arrester is dis-

    connected from PE by the gas-filled spark gap.

    Only for use in TN systems.

    DESCRIPTION PU TYPE ORDER NO.

    D surge arrester Module 3kA, 1 MW 6 VMG 275 IS010200

    Base for VMG / VEPG 12 VMS IS010201

    Base + H for VMG / VEPG 12 VMSH IS010202

  • 8/14/2019 Surge Voltage Protection

    17/22

    SURGE ARRESTERS, CLASS D

    435

    W TECHNICAL DATA Test class II following IEC 61643-1

    Class D following VE-SN 60, part 1

    Response time (RRV 5kV/s) ta < 25 ns

    Continuous voltage UE: 280 V, 335 V, AC

    Combined impact Uoc L-N / N-PE: 5 kV / 10 kV Level of protection UP at Uoc L-N /N-PE: 900 V /

    1000 V / 1200 V

    Rated discharge current In L-N/L-PE/N-PE: 2,5 kA/

    2,5 kA/5 kA (8/20 s)

    Level of protection UP at In L-N/L-PE/N-PE: 900 V/

    1900 V/ 1000 V

    Max. discharge current L-N/L-PE/N-PE: 5 kA/5 kA/

    10 kA (8/20 s)

    Max. permitted back-up fuse: 63 A gL/C63

    Max. permitted short-circuit protection: 10 kA

    Max. permissible ambient temperature: -40 C to +70 C Built-in contactor: IP 40

    Gap terminals on both sides for conductor

    cross-section 1 -25 mm2

    Claw-type terminal on both sides for rails

    up to 1,5 mm in strength

    Torque for screw terminals 2,4

    up to 3 Nm

    Quick-fastening onto rail in accordance with EN 50,022

    Installation class 3 according to IEC 1000-4-5

    UAS-FM auxiliary contact can be fitted for remote

    signalling No need to decouple upstream surge protection

    W TIPS & TRICKSA L-N and N-PE surge arrester module must always be used

    for the correct degree of protection. See circuit diagram.

    The use of identical modules does not ensure

    adequate protection.

    W RANGE OF APPLICATIONUsed to protect terminal units against transient surges

    as low-voltage device arresters.

    W D SURGE ARRESTER, AD2 SERIES, 2 MODUL WIDE PGR 4954

    is0500m2.eps

    is0500m1.epsis0500gf.eps

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Modular D surge arrester N/L, 2,5 kA, 280 VAC 17,5x80x71,5 12 AD2-LN 0,065 IS050022

    Modular D surge arrester N/PE (spark gap), 5 kA, 280 VAC 17,5x80x71,5 12 AD2-NPE 0,065 IS050021

    Mounting for 2-pole modular installationD surge arrester 280 V 35x80x49,5 6 AD2-SA 0,1 IS050023

    Modular D surge arrester N/L, 2,5 kA, 335 VAC 17,5x80x71,5 12 AD2-A 0,065 IS050025

    Modular D surge arrester N/PE (spark gap), 2.5 kA, 260 VAC 17,5x80x71,5 12 AD2-AF 0,07 IS050026

    Mounting for 2-pole modular installationD surge arrester 335 V. 335VAC 35x80x49,5 6 AD2-F 0,1 IS050027

  • 8/14/2019 Surge Voltage Protection

    18/22

    DESCRIPTION PU TYPE ORDER NO.

    D Surge arrester for plug socket, 2,5 kA 1 USM 01 IS010001

    D Surge arrester for plug socket, 2,5 kA, through-wiring 1 USM 01/2 IS010002

    W TECHNICAL DATA Requirement class D

    Rated discharge current (8/20 s) Isn: 2.5 kA

    Rated voltage Uc: 250 V~ (50Hz)

    Max. load circuit current I max:16 A Connection type: 3 wire

    Response time: L - N < 25 ns

    Short-circuit protection: 6 kA (back-up fuse 16 AgL)

    Temperature range: -20 C to 60 C

    W TIPS & TRICKSFor the equipping of new and retrofitting of existing earthed sockets (e.g. earthed sockets

    from ELSO range). Can be integrated in flush-mounted enclosure boxes. Through-wiring

    model enables other plug sockets to be connected.

    W RANGE OF APPLICATIONThe protective device is primarily designed for fusing sensitive electronic devices mains-side,

    and is suitable for universal application in flush-mounted modular device- and enclosure

    sockets. This device allows you to equip already existing flush-mounted plug sockets with

    surge protection. The protective device is clamped into a FM- device insert using a spring

    clip after the L, N and PE conductors are connected to the plug socket- on the device side.

    Afterwards, the plug socket is mounted as usual.

    This enables the user not only to equip plug sockets to be installed for the first time but

    also to retrofit existing plug sockets, regardless of individual models of different

    manufacturers.

    The switching operation of the device provides parallel protection. This ensures that supply

    to the protected device- mains-side is maintained even if the protective device is damaged.

    Fault indication is provided by a sensor integrated in the device. This indicates when protec-

    tion is no longer provided, in which case the protective device should be replaced by an

    electrician as soon as possible.

    W PLUG SOCKETS INSERTABLE PROTECTION MODULE

    SURGE ARRESTERS, CLASS D

    36

    is0102_mon.eps

    is010001.eps

  • 8/14/2019 Surge Voltage Protection

    19/22

    W TECHNICAL DATA Surge arrester class D - meets VDE 0675, part 6/A3 11.97

    Test class II meets IEC 61643-1

    Continuous voltage Uc 250V/50 Hz

    Max. permissible back-up fuse 16 A gL

    Nominal discharge current isn (8/20)s symm./asymm. (PE) 1,5 kA

    Max. discharge current Imax (8/20)s symm./asymm.(PE) 4,5 kA

    Response time symm. < 25 ns / asymm.(PE) < 100 ns

    Residual voltage at Isn symm. < 1,2 kV / asymm.(PE) < 650 V

    Protection level at UOC symm./asymm. 1.5 kV

    Temperature range -40C to +75 C

    Degree of protection according to IEC 529: 1989 IP 20

    Integrated FM contact integriert: max. permissible operating vol-

    tage 250 V AC, max. permissible operating current 3 A / 45 C

    Mounting in cable channels and flush-mounted sockets

    accord. to DIN 49073

    Connections fixed/mm2 flexibel/mm2

    Mains 0,2 - 4 0,2 - 2,5

    FM contact 0,14 - 1,5 0,14 - 1,0

    W RANGE OF APPLICATIONProtects terminal devices against transient voltage surges.

    W ALSO REFER TO THE SPECIAL CATALOG UEK-SE-ELSO4

    W CAUTION!A class C/II surge arrester must be installed upstream in the

    enclosures to prevent the device from being overloaded.

    PGR 4954W PLUG-IN DEVICE ARRESTER, FLUSH-MOUNTED

    SURGE ARRESTER, CLASS D

    437

    is050001.eps

    is05_m.eps

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Plug-in base 71x47,5x43 1 GS 230 S 0,034 IS050000

    Varistor insert 33x31,5x32,5 1 GS 230 E 0,016 IS050001

    ELSO frame, 1x (For additional details, colours, types etc.refer to the Special Catalogue K-SE-ELSO4) - 1 Fashion pear l whi te - EL204100

    ELSO frame, 2x (For additional details, colours, types etc.refer to Special Catalogue K-SE-ELSO4) - 1 Fashion pure whi te - EL204104

    ELSO cover plate Fashion, pearl white (For additional details,colours, types etc., refer to Special Catalogue K-SE-ELSO4) - 1 Fashion pear l whi te - EL206010

    ELSO cover plate, pure white (further details, colours,types etc., see Special Catalogue K-SE-ELSO4) - 10 Fashion pure whi te - EL206014

    Cover plate, alternative to ELSO - 1 DA 0,009 IS050002

    Cover frame, alternative to ELSO - 1 RA 0,014 IS050003

    N N PE PE L L

    28

    GS 230 SSockel

    71

    47,5

    47,5

    3443

    is05_3m.epsis05_2m.eps

    is05_1m.eps

  • 8/14/2019 Surge Voltage Protection

    20/22

    DESCRIPTION PU TYPE WEIGHT ORDER NO.

    ELSO, 2,5 kA, w/o frame (further details,colours, types etc. see Special Catalogue K-SE-ELSO4) 1 Fash ion pear l wh i te - EL215130

    ELSO, 2,5 kA, w/o frame (further details,colours, types etc. see Special Catalogue K-SE-ELSO4) 1 Fashion pure wh ite - EL215134

    Surge arrester socket w/ optical and acoustic sensor 1 SKTG 0,132 IS010011

    W TECHNICAL DATA Surge arrester class D - meets VDE 0675, part 6/A3 11.97

    Test class II meets IEC 61643-1

    Continuous voltage UC 250V/50 Hz Max. permitted back-up fuse: 16 A gL

    Nominal discharge current lSN (8/20 s): 1,5 kA, 2,5 kA

    Max. discharge current Imax (8/20 s): 4.5 kA

    Response time symm. < 25 ns / asymm. (PE) < 100 ns

    Level of protection: symm. < 1,2 kV / asymm. (PE) < 1,0 kV

    Temperature range -20 C to +75 C

    Degree of protection according to IEC 529: 1989 IP 20

    Acoustic defect indicator IS010010

    LED defect indicator IS 010010

    Rated voltage accord. to VE-EN1, part 1, art. 18

    W RANGE OF A PPLICATIONEarthed plug socket with integrated surge protection for

    mounting in flush-mounted sockets, used to protect terminal

    devices from transient voltage surges.

    W ALSO REFER TO TH E SP ECIAL CATALOGUEK-SE-ELSO4

    W CAUTION!A class C/II surge arrester must be installed upstream in the

    enclosures to prevent these devices from being overloaded.

    PGR 4954W PROTECTIVE PLUG SOCKET, FLUSH-MOUNTED

    SURGE ARRESTERS, CLASS D

    38

    is01_11f.epsel215130.eps

  • 8/14/2019 Surge Voltage Protection

    21/22

    ARRESTER DISCONNECTOR SWITCH, INDUCTIVE DECOUPLING

    439

    DESCRIPTION DIM. (WxHxD) PU TYPE WEIGHT ORDER NO.

    Inductive decoupling, 35 A 35x90x64 1 LBA 35 0,408 IS010043

    35

    45

    58

    43,5

    90

    PGR 4320W INDUCTIVE DECOUPLING - TO BE DISCONTINUED

    W UPON REQUEST

    PGR 4959WARRESTER DISCONNECTOR SWITCH

    bd900600.eps

    is010043.epsis01_43s.eps

    is01_43m.eps

  • 8/14/2019 Surge Voltage Protection

    22/22

    40

    NOTES