608 South St. South Kirkland, WA 98033 www.faira.com [email protected] 1 (800) 571-FAIR FAIRA TRANSPARENCY REPORT 3034 NE Arta Ct, Bremerton, WA 98311 December 14, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Upload: others

Post on 24-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

608 South St. South Kirkland, WA 98033

www.faira.com [email protected] 1 (800) 571-FAIR

FAIRA TRANSPARENCY REPORT

3034 NE Arta Ct, Bremerton, WA 98311

December 14, 2018

Thank you for your interest in this Faira Certified home.

We have coordinated the efforts of certified and licensed inspection and title professionals to createthe Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolioof information that is prepared on behalf of buyers in preparation for making an informed offer on theproperty.

You may view more detailed information for this home and can make an offer at

All of the information in the Faira Transparency Reports was gathered and compiled without any biasor influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s)ordered the same professionals to perform the evaluations on the same date. Nevertheless, Fairatakes no obligation of the reports being complete or accurate. The buyers are recommended toconduct their own due-diligence to their satisfaction.

Please contact us if you have any questions or would like more information.

We're happy you've chosen a Faira Certified home and look forward to the opportunity of working withyou!

The Faira Team

Page 2: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Inspection Report for Mrs. Sheila TallmanProperty Address: 3034 NE Arta Ct., Bremerton, Washington 98311

NW WASHINGTON HOME INSPECTIONS LLC

Carl Liberman License #1758Bainbridge Island, Washington

Page 3: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Table of Contents

Cover Page.................................................................1

Table of Contents ........................................................2

Intro Page ...................................................................3

Significant Issues ........................................................5

Repair & Maintenance Summary ................................6

Future Improvements..................................................9

1 Roof ....................................................................... 11

2 Attic ........................................................................14

3 Exterior...................................................................18

4 Wall Exteriors.........................................................24

5 Structure ................................................................26

6 Electrical ................................................................27

7 Garage...................................................................32

8 Interior....................................................................34

9 Plumbing ................................................................37

10 Heating.................................................................40

11 Bathrooms............................................................43

12 Kitchen and Built-in Appliances ...........................46

13 Laundry Room .....................................................49

Invoice.......................................................................50

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 2 of 50

Page 4: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Date: 12/13/2018 Time: 01:00 PM Report ID: 181213 AProperty:3034 NE Arta Ct.Bremerton Washington 98311

Customer:Mrs. Sheila Tallman

Real Estate Professional:Chris EllisFaira.com

Dear Mrs. Tallman,

Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.

Three summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. Future improvements are provided for your consideration.

The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.

If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at [email protected]. I look forward to providing future home inspection needs to you, yourfriends, and family.

Warm Regards,

Carl Liberman

Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.

Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.

Future Improvements ( ) = Items or discoveries indicate that these systems or components should be considered forupgrade and/or modernization. Improved safety and/or energy efficiency may apply.

Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence ofpests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does notrespond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 3 of 50

Page 5: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

Standards of Practice:Washington State Standards of Practice forHome Inspectors & Inspections (WAC308-408C)

Type of building::Single Family (2-story)

Approximate Square Footage::1758

Approximate Year of OriginalConstruction::1983

Occupancy::Unoccupied, empty of furniture

Attending the Inspection::Owner

Weather during the Inspection::Light Rain

Significant precipitation in last 3 days::No

Temperature during inspection::Below 60 (F) = 15.5 (C)

Ground/Soil surface condition:Wet

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 4 of 50

Page 6: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.

1. Roof

1.5 Asphalt Composition ShingleThis asphalt shingle roof may be near the end of it's useful life as indicated by generally loss of shingle dexterity,loss of aggregate, some noted shingle damage, and noted replaced shingles. The typical life expectancy of asphaltshingle roofs in this climate is approximately 20 years, please budget accordingly. Please further consult a licensedroofing contractor for roof replacement options and costs.

2. Attic

2.2 Roof SheathingI noted signs of excessive moisture in the attic as indicated by organic growth build-up on the sheathing.Contributing may be poorly vented bathroom fans (see section 2.6) and/or inadequately attic ventilation (see section2.3). Further consult an attic remediation specialist and/or a roofing contractor for options and costs to correct.

Please note this section is not all-inclusive, please read the complete report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 5 of 50

Page 7: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.

1. Roof

1.0 Roof Structure ExteriorThe roof terminates and the fascia board is left exposed in an area directly over the front porch. I would recommendflashing and/or other means to protect the trim from the elements. These conditions are conducive to wooddestroying organisms.

2. Attic

2.3 Roof Structure VentilationRoof ventilation is provided by gable vents and soffit vents. Roof ventilation may be insufficient as indicated byorganic growth build-up on the roof sheathing. Roof vents or ridge vent(s) were not installed (typical for modern roofinstallations). A minimum of 1 square foot of attic ventilation for every 300 square feet of attic floor space isrecommended. Please further consult a roofing contractor or options and costs to improve attic ventilation.

2.4 Attic ElectricalThis light-can electrical connections are made outside the junction box. Recommend correction by a qualifiedcontractor.

2.5 Attic Thermal EnvelopeI would recommend insulating the attic access hatch.

2.6 Venting Systems (Kitchens, Baths and Laundry)Both bathroom ventilation fan discharges through the roof vent passing through several sections of joined ventilationpiping. I would recommend replacing the vent piping with an insulated single section of piping and discharge throughdedicated vent connectors. Leaking ventilation piping can cause excessive moisture conditions within the attic.

3. Exterior

3.3 General Grounds(2) I would recommend removing this large standing dead tree due to it's proximity to the house structure.

3.5 Porch(1) This decking under the front porch is in direct contact with the soil. This condition is conducive to wooddestroying organisms.

4. Wall Exteriors

4.2 Exterior Wall PenetrationsI would recommend sealing this opening created by the gas main line through the garage wall.

4.3 Wood SidingA loose siding board is noted to the right of the garage doors.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 6 of 50

Page 8: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

6. Electrical

6.8 Service Panel WiringThis connection is suspect as an undersized wire may have been used for connection to the neutral bus. I wouldrecommend inspection/correction by a licensed electrician.

6.15 GFCI/AFCI Electrical Receptacles(1) GFCI outlets in the garage and both bathrooms were not operational when tested (no power).

(2) Limited ground fault circuit interrupter (GFCI) protection of home electrical receptacles was provided in the homeat the time of inspection. Although GFCI protection may not have been required at the time the home was built, theInspector recommends that electrical receptacles located in basements, crawlspaces, garages, the home exterior,and interior receptacles located within 6 feet of a plumbing fixture be provided with ground fault circuit interrupter(GFCI) protection for improved electrical safety.

6.18 Visible Branch WiringThe electrical feed for the furnace should be housed in approved electrical conduit.

7. Garage

7.0 Vehicle Doors1. The right hand garage door (facing from outside) binds when closing and does not fully close

automatically. Adjustment/repairs required.2. Neither door has a photo-senor installed for additional safety, installation recommended.

7.1 Conventional DoorsThe garage door to the living space should be self closing. I would recommend the installation of self-closing hingesor other similar mechanism.

8. Interior

8.4 Doors(1) This bedroom door does not latch.

(2) The dining area sliding door lock is loose.

(3)1. The front door needs new weather-stripping.2. The dead--bolt requires a latching plate.

9. Plumbing

9.4 Gas Water Heater(1)

1. Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion.Strappings shall be at points within the upper one-third and lower one-third of its vertical dimensions. At thelower point, a distance of not less than four (4) inches (102 mm) shall be maintained from the controls tothe strapping.

2. A surge tank is recommended.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 7 of 50

Page 9: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

10. Heating

10.1 FurnaceThis joint in the exhaust plenum inside the furnace cabinet is leaking. I would recommend repairs and generalservicing by a heating contractor.

11. Bathrooms

11.10 Toilet1. The upstairs toilet is loose on it's pedestal, requiring adjustment to avoid a future leak.2. I would recommend caulking the base of both toilets at the floor.

11.11 ShowerThe downstairs shower control valve does not deliver hot water and has limited motion. I would recommendadjustment by a qualified contractor.

11.12 SinkI would recommend caulking the back-splash(s) on both bathroom sinks.

12. Kitchen and Built-in Appliances

12.10 RangeThe range was not fastened to the floor. A child standing on the open oven door could overturn the range. I wouldrecommends installation of an approved anti-tip device by a qualified contractor.

12.12 DishwasherWater emitted from the air-gap during testing of the dishwasher. I would recommend correction by a qualifiedcontractor.

12.14 SinkPlease note, the cold water was secured to the kitchen sink when tested.

Please note this section is not all-inclusive, please read the complete report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 8 of 50

Page 10: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

Future Improvements

1. Roof

1.2 Roof FlashingNo drip edge flashing was installed at the time of the inspection. Lack of drip edge flashings may leave the edges ofroof sheathing and underlayment exposed to the deteriorating effects of weather, with damage from moisture suchas delamination and decay possible. I would recommend further consulting a roofing contractor for options and costto upgrade.

3. Exterior

3.5 Porch(2) I would recommend improving ledger connection (adding ledger lag screws) and adding joist hangers for thedecking joists and stair stringers. Please see http://www.awc.org/pdf/codes-standards/publications/dca/AWC-DCA62012-DeckGuide-1405.pdf for further guidelines. Additional local guidelines may apply.

3.6 Deck, Balcony, Bridge and Porch,(2)

1. The back deck railing system does not utilize 4X4 bolted posts (recommended every 4 feet).2. The ledger board from the 2nd story deck does not appear to be bolted or flashed. Joist and stair stringers

were not used.3. No graspable handrail for the stairs is installed.

Please see http://www.awc.org/pdf/codes-standards/publications/dca/AWC-DCA62012-DeckGuide-1405.pdf for bestpractices. Additional local guidelines may apply.

6. Electrical

6.15 GFCI/AFCI Electrical Receptacles(3) The light for the downstairs bathroom is not independently wired from the laundry room.

6.19 Smoke DetectorsSmoke detectors are recommended on each floor of the home, in each bedroom of the home, outside commonbedroom areas. Install in accordance with manufactures recommend guidance or hire a licensed contractor forproper installation. Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040

9. Plumbing

9.4 Gas Water Heater(2) Please note, this water heater has exceeded it's typical life-span of 12 to 18 years. Consider a home warranty tomitigate repair/replacement costs. Budget for a replacement in the future.

11. Bathrooms

11.8 VentilationConsider adding an exhaust fan to the downstairs shower area.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 9 of 50

Page 11: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 10 of 50

Page 12: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.

Styles & Materials

Method of inspection:Walked the roof

The roof style was:Gable

Primary roof-covering type:3-tab Fiberglass Asphalt Shingle

Drainage system description:Gutters and downspouts installed

Chimney flue material:Metal

Underlayment/Interlayment::Not Visible

Sky Light(s):None

Items

1.0 Roof Structure ExteriorComments: Inspected

1.1 UnderlaymentComments: Inspected

1.2 Roof FlashingComments: Inspected

The roof terminates and the fascia board is left exposed in an area directly over the front porch. I wouldrecommend flashing and/or other means to protect the trim from the elements. These conditions areconducive to wood destroying organisms.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 11 of 50

Page 13: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

1.3 Roof Drainage SystemComments: Inspected

1.4 Plumbing and Combustion VentsComments: Inspected

1.5 Asphalt Composition ShingleComments: Inspected

No drip edge flashing wasinstalled at the time of the inspection.Lack of drip edge flashings may leavethe edges of roof sheathing andunderlayment exposed to thedeteriorating effects of weather, withdamage from moisture such asdelamination and decay possible. Iwould recommend further consulting aroofing contractor for options and costto upgrade.

This asphalt shingle roof may be near the end of it's useful life as indicated by generally loss of shingledexterity, loss of aggregate, some noted shingle damage, and noted replaced shingles. The typical lifeexpectancy of asphalt shingle roofs in this climate is approximately 20 years, please budget accordingly.Please further consult a licensed roofing contractor for roof replacement options and costs.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 12 of 50

Page 14: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

damaged shingles

shingles appear to have been replaced

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 13 of 50

Page 15: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).

Styles & Materials

Attic info:Scuttle hole

Attic inspected from:Inside the attic

Attic thermal insulation material:Blown-in Fiberglass

Approximate attic thermal insulationdepth:

R-19 or better

Roof Structure Ventilation:Further evaluation required

Roof structure ventilation device type:Gable ventsSoffit vents

Roof Framing Type:Manufactured Roof Trusses

Roof Sheathing Material:Plywood

Items

2.0 Attic AccessComments: Inspected

2.1 Roof Framing (from attic)Comments: Inspected

2.2 Roof SheathingComments: Inspected

I noted signs of excessive moisture in the attic as indicated by organic growth build-up on the sheathing.Contributing may be poorly vented bathroom fans (see section 2.6) and/or inadequately attic ventilation (seesection 2.3). Further consult an attic remediation specialist and/or a roofing contractor for options and costs tocorrect.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 14 of 50

Page 16: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

2.3 Roof Structure VentilationComments: Inspected

2.4 Attic ElectricalComments: Inspected

Roof ventilation is provided bygable vents and soffit vents. Roofventilation may be insufficient asindicated by organic growth build-upon the roof sheathing. Roof vents orridge vent(s) were not installed (typicalfor modern roof installations). Aminimum of 1 square foot of atticventilation for every 300 square feet ofattic floor space is recommended.Please further consult a roofingcontractor or options and costs toimprove attic ventilation.

This light-can electricalconnections are made outside thejunction box. Recommend correctionby a qualified contractor.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 15 of 50

Page 17: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

2.5 Attic Thermal EnvelopeComments: Inspected

2.6 Venting Systems (Kitchens, Baths and Laundry)Comments: Inspected

2.7 Attic Rodent ActivityComments: Inspected

I would recommend insulating theattic access hatch.

Both bathroom ventilation fan discharges through the roof vent passing through several sections ofjoined ventilation piping. I would recommend replacing the vent piping with an insulated single section of pipingand discharge through dedicated vent connectors. Leaking ventilation piping can cause excessive moistureconditions within the attic.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 16 of 50

Page 18: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 17 of 50

Page 19: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.

The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.

Styles & Materials

Driveway Material:Asphalt

Walkway Materials:Concrete

Appurtenance:Deck with stepsPorch

Downspout Discharge:Below Grade

Lot Description:Moderate Slope

Clearance to Grade:Standard

Items

3.0 Exterior ViewsComments: Inspected

3.1 DrivewayComments: Inspected

3.2 WalkwaysComments: Inspected

3.3 General GroundsComments: Inspected

(1) I would recommend trimming the tree limbs away from the structure to prevent physical damage and avoida path for pests and animals.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 18 of 50

Page 20: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

3.4 Exterior TrimComments: Inspected

3.5 PorchComments: Inspected

(2) I would recommend removingthis large standing dead tree due to it'sproximity to the house structure.

(1) This decking under the frontporch is in direct contact with the soil.This condition is conducive to wooddestroying organisms.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 19 of 50

Page 21: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

3.6 Deck, Balcony, Bridge and Porch,Comments: Limitation

(2) I would recommend improving ledger connection (adding ledger lag screws) and adding joist hangersfor the decking joists and stair stringers. Please see http://www.awc.org/pdf/codes-standards/publications/dca/AWC-DCA62012-DeckGuide-1405.pdf for further guidelines. Additional local guidelines may apply.

(1) Please note, my inspection of theback deck framing was limited due toinadequate access from below.

limited access

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 20 of 50

Page 22: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

(2)1. The back deck railing system does not utilize 4X4 bolted posts (recommended every 4 feet).2. The ledger board from the 2nd story deck does not appear to be bolted or flashed. Joist and stair

stringers were not used.3. No graspable handrail for the stairs is installed.

Please see http://www.awc.org/pdf/codes-standards/publications/dca/AWC-DCA62012-DeckGuide-1405.pdffor best practices. Additional local guidelines may apply.

no 4X4 posts inadequete ledger attachment

no graspable hand-rail

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 21 of 50

Page 23: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

3.7 Additional StructuresComments: Not Inspected

(1) Storage building - not inspected.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 22 of 50

Page 24: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

3.8 DrainageComments: Inspected

The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

(2) Hot tub - not inspected.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 23 of 50

Page 25: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.

The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.

Styles & Materials

Exterior wall-covering Material:Horizontal Lapped Wood Siding

Exterior Doors:Solid wood

Items

4.0 Door ExteriorsComments: Inspected

4.1 Window ExteriorsComments: Inspected

4.2 Exterior Wall PenetrationsComments: Inspected

4.3 Wood SidingComments: Inspected

I would recommend sealing thisopening created by the gas main linethrough the garage wall.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 24 of 50

Page 26: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

A loose siding board is noted tothe right of the garage doors.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 25 of 50

Page 27: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.

Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.

Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.

Styles & Materials

Typical Ceiling Structure:Drywall attached to roof trusses

Exterior Wall Structures:Conventional 2x6 Wood Frame

Wall Insulation:Not Visible

Foundation Configuration:Finished basement

Foundation Method/Materials:Poured concrete foundation walls

% Foundation Not Visible:90%

Main Floor Structure:Not visible

Main Floor Structure- Perimeter Bearing:Not Visible

Main Floor Structure- IntermediateSupport:

Not visible

Floor System Insulation:Not visible

Items

5.0 Exterior Wall ConstructionComments: Limitation

5.1 Floor StructureComments: Not Inspected

5.2 Insulation Under Floor SystemComments: Not Inspected

5.3 FoundationComments: Limitation

5.4 Crawl Space Rodent ActivityComments: Limitation

The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

not visible.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 26 of 50

Page 28: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.

The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting

Styles & Materials

Electrical Service Conductors:Underground serviceAluminum120/240 volt service

Service Panel Ampacity:200 amps

Service Panel Type:Load Center

Service Panel Manufacturer:Cuttler Hammer

Service Disconnect Location:At Service Panel

Service Disconnect Type:Breaker

Service Grounding Electrode:Not Visible

Wiring Methods:Romex

Type of Branch Wiring:Solid CopperStranded CopperStranded Aluminum

Ground Fault Circuit Interruptor (GFCI)Protection:

NO

Arc Fault Circuit Interruptor (AFCI)Protection:

NO

Items

6.0 General Electrical System DescriptionComments: Inspected

6.1 General Electrical System ConditionComments: Inspected

6.2 Mast & WeatherheadComments: Inspected

6.3 Electric MeterComments: Inspected

6.4 Service Entrance ConductorsComments: Inspected

6.5 Service Panel ManufacturerComments: Inspected

6.6 Service Panel Exposure RatingComments: Inspected

6.7 Service Panel Cabinet, Ampacity, and CoverComments: Inspected

6.8 Service Panel WiringComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 27 of 50

Page 29: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

6.9 Service DisconnectComments: Inspected

6.10 Overcurrent Protection DevicesComments: Inspected

6.11 Service Grounding Electrode System & Service BondComments: Inspected

6.12 Equipment Grounding & BondingComments: Inspected

6.13 Exterior Electrical ReceptaclesComments: Inspected

6.14 Conventional Electrical Receptacles (interior)Comments: Inspected

6.15 GFCI/AFCI Electrical ReceptaclesComments: Inspected

This connection is suspect as anundersized wire may have been usedfor connection to the neutral bus. Iwould recommend inspection/correction by a licensed electrician.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 28 of 50

Page 30: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

(1) GFCI outlets in the garage and both bathrooms were not operational when tested (no power).

(2) Limited ground fault circuitinterrupter (GFCI) protection of homeelectrical receptacles was provided inthe home at the time of inspection.Although GFCI protection may nothave been required at the time thehome was built, the Inspectorrecommends that electricalreceptacles located in basements,crawlspaces, garages, the homeexterior, and interior receptacleslocated within 6 feet of a plumbingfixture be provided with ground faultcircuit interrupter (GFCI) protection forimproved electrical safety.

kitchen counter, no GFCI.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 29 of 50

Page 31: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

6.16 SwitchesComments: Inspected

6.17 LightingComments: Inspected

6.18 Visible Branch WiringComments: Inspected

6.19 Smoke DetectorsComments: Inspected

(3) The light for the downstairsbathroom is not independently wiredfrom the laundry room.

The electrical feed for the furnaceshould be housed in approvedelectrical conduit.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 30 of 50

Page 32: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

6.20 Carbon Monoxide DetectorsComments: Inspected

6.21 DoorbellComments: Inspected

The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

Smoke detectors arerecommended on each floor of thehome, in each bedroom of the home,outside common bedroom areas.Install in accordance withmanufactures recommend guidance orhire a licensed contractor for properinstallation. Reference WAC212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 31 of 50

Page 33: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

7. GarageInspection of the garage typically includes examination of the following:general structure; floor, wall and ceiling surfaces; operation of all accessibleconventional doors and door hardware; vehicle door condition and operation proper electrical condition including Ground Fault Circuit Interrupter(GFCI) protection; interior and exterior lighting; stairs and stairways proper firewall separation from living space; and proper floor drainage

Styles & Materials

Garage Vehicle Door Type:Single

Number of Vehicle Doors:2

Number of Automatic Openers:2

Vehicle Door Automatic Reverse:No photosensor

Auto-opener Manufacturer:Craftsman

Items

7.0 Vehicle DoorsComments: Inspected

7.1 Conventional DoorsComments: Inspected

1. The right hand garage door (facing from outside) binds when closing and does not fully closeautomatically. Adjustment/repairs required.

2. Neither door has a photo-senor installed for additional safety, installation recommended.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 32 of 50

Page 34: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

7.2 FloorsComments: Inspected

7.3 WallsComments: Inspected

7.4 CeilingComments: Inspected

7.5 Fire SeparationComments: Inspected

7.6 Garage ElectricalComments: Inspected

The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

The garage door to the livingspace should be self closing. I wouldrecommend the installation of self-closing hinges or other similarmechanism.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 33 of 50

Page 35: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

8. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.

Styles & Materials

Walls and Ceilings:Drywall

Floor Covering Materials:CarpetVinyl Strip

Interior Doors:Wood Hollow Core

Window Material:Vinyl

Window Glazing:Double-pane

Window Operation:Sliding

Smoke/CO Detectors:Smoke detectors installedCarbon monoxide detector(s) installed

Items

8.0 FloorsComments: Inspected

8.1 WallsComments: Inspected

8.2 CeilingsComments: Inspected

8.3 LightingComments: Inspected

8.4 DoorsComments: Inspected

(1) This bedroom door does not latch.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 34 of 50

Page 36: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

8.5 Windows and SkylightsComments: Inspected

8.6 Interior TrimComments: Inspected

8.7 Cabinets and CountertopsComments: Inspected

8.8 StairsComments: Inspected

8.9 Bathroom and Laundry VentilationComments: Inspected

(2) The dining area sliding doorlock is loose.

(3)1. The front door needs new

weather-stripping.2. The dead--bolt requires a

latching plate.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 35 of 50

Page 37: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 36 of 50

Page 38: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

9. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).

Styles & Materials

Water Supply Source:Public Water Supply

Main Water Supply Pipe:3/4-inchCopper

Main Water Supply Location:Garage

Water Distribution Pipes:1/2-inch and 3/4-inch copperNot Visible

Distribution Pipe Bonding:Pipes were bonded

Sewage System Type:Public

Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)Not Visible

Water Heater Manufacturer:Unable to determine (missing/illegible

information)

Date of Manufacture:1983

Water Heater Fuel Type:Gas

Water Heater Type:Tank (conventional)

Water Heater Tank Capacity:40 gallons

Water Heater Location:Garage

Washer Drain Size:2" Diameter

Gas Pipe Material:Black Steel

Type of Gas:Natural Gas

Items

9.0 Exterior PlumbingComments: Inspected

9.1 Source of WaterComments: Inspected

9.2 Water Supply and DistributionComments: Inspected

9.3 Sewage and DWV SystemsComments: Inspected

Main water cut-off located in thegarage.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 37 of 50

Page 39: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

9.4 Gas Water HeaterComments: Inspected

(1)1. Water heaters shall be

anchored or strapped toresist horizontaldisplacement due toearthquake motion.Strappings shall be at pointswithin the upper one-thirdand lower one-third of itsvertical dimensions. At thelower point, a distance of notless than four (4) inches (102mm) shall be maintainedfrom the controls to thestrapping.

2. A surge tank isrecommended.

(2) Please note, this water heaterhas exceeded it's typical life-span of12 to 18 years. Consider a homewarranty to mitigate repair/replacement costs. Budget for areplacement in the future.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 38 of 50

Page 40: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 39 of 50

Page 41: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

10. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).

Styles & Materials

Heating System Type:Gas-fired Furnace (medium efficiency)

Energy Source:Electric

Number of Heat Systems (excludingwood):

One

Heating/Cooling Ducts:Insulated

Air Filter:Washable

Air Filter Location:Inside blower compartment

Heating System Brand:Coleman

Types of FIreplaces:Vented gas logs

Operational Fireplaces:One

Number of Woodstoves:None

Items

10.0 Presence of installed heat source in each roomComments: Inspected

10.1 FurnaceComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 40 of 50

Page 42: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

10.2 Fuel, Piping and SupportComments: Inspected

10.3 ThermostatComments: Inspected

10.4 Filter conditionComments: Inspected

This joint in the exhaust plenum inside the furnace cabinet is leaking. I would recommend repairs andgeneral servicing by a heating contractor.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 41 of 50

Page 43: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

10.5 FireplaceComments: Inspected

The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 42 of 50

Page 44: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

11. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation

Styles & Materials

Exhaust Fans:Fan only

Items

11.0 FloorsComments: Inspected

11.1 WallsComments: Inspected

11.2 CeilingsComments: Inspected

11.3 DoorsComments: Inspected

11.4 WindowsComments: Inspected

11.5 SkylightsComments: Inspected

11.6 Electrical Receptacles and SwitchesComments: Inspected

11.7 LightingComments: Inspected

11.8 VentilationComments: Inspected

11.9 CabinetsComments: Inspected

Consider adding an exhaust fanto the downstairs shower area.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 43 of 50

Page 45: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

11.10 ToiletComments: Inspected

11.11 ShowerComments: Inspected

11.12 SinkComments: Inspected

1. The upstairs toilet is loose on it's pedestal, requiring adjustment to avoid a future leak.2. I would recommend caulking the base of both toilets at the floor.

The downstairs shower controlvalve does not deliver hot water andhas limited motion. I wouldrecommend adjustment by a qualifiedcontractor.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 44 of 50

Page 46: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.

I would recommend caulking the back-splash(s) on both bathroom sinks.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 45 of 50

Page 47: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

12. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.

Styles & Materials

Cabinets:Solid Wood

Countertop Material:Granite

Range:Gas

Range/Oven Brand:Frigidaire

Range Hood:Vents to exterior

Range Hood Brand:Nutone

Dishwasher:Present, Inspected

Dishwasher brand:Frigidair

Dishwasher Anti-siphon method:Air gap installed

Refrigerator:None Present

Items

12.0 FloorsComments: Inspected

12.1 WallsComments: Inspected

12.2 CeilingsComments: Inspected

12.3 DoorsComments: Inspected

12.4 WindowsComments: Inspected

12.5 SkylightsComments: Inspected

12.6 Interior TrimComments: Inspected

12.7 Receptacles and SwitchesComments: Inspected

12.8 LightingComments: Inspected

12.9 CabinetsComments: Inspected

12.10 RangeComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 46 of 50

Page 48: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

12.11 Range HoodComments: Inspected

12.12 DishwasherComments: Limitation

12.13 CounterComments: Inspected

12.14 SinkComments: Limitation

The range was not fastened tothe floor. A child standing on the openoven door could overturn the range. Iwould recommends installation of anapproved anti-tip device by a qualifiedcontractor.

Water emitted from the air-gapduring testing of the dishwasher. Iwould recommend correction by aqualified contractor.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 47 of 50

Page 49: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

Please note, the cold water wassecured to the kitchen sink whentested.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 48 of 50

Page 50: The Faira Team...The garage door to the living space should be self closing. I would recommend the installation of self-closing hinges or other similar mechanism. 8. Interior 8.4 Doors

13. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.

Styles & Materials

Dryer Power:Electric

Dryer 240-volt electrical receptacle:Installed

Items

13.0 FloorsComments: Inspected

13.1 WallsComments: Inspected

13.2 CeilingsComments: Inspected

13.3 DoorsComments: Inspected

13.4 WindowsComments: Inspected

13.5 Receptacles, Switches, ConnectionsComments: Inspected

13.6 LightingComments: Inspected

13.7 CabinetsComments: Inspected

13.8 Dryer VentingComments: Not Inspected

13.9 Washer/DryerComments: Not Inspected

The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.

NW WASHINGTON HOME INSPECTIONS LLC Tallman

3034 NE Arta Ct. Page 49 of 50