tekn90sc e 221112 - vallox · 2016. 7. 1. · – ptxpa slim-line sc cooker hood – insulated...

8
© VALLOX • We reserve the right to make changes without prior notification. What the units include can vary depending on the sales area. TECHNICAL SPECIFICATION VALLOX 90 SC R VALLOX 90 SC L Models: Highly efficient heat recovery ( > 80%) Energy-efficient integrated direct- current fans 4-step Simple Control adjustment Preheating with electricity (option) SC • 1.09.346F • 22.11.2012 • Code A3521-1/2 © VALLOX Code A3521-1/2 Supply air Extract air 92 dm 3 /s 50 Pa 75 dm 3 /s 50 Pa 0,119 kW 0,9 A 0,119 kW 0,9 A Heat recovery Heat recovery bypass Filters – Simple Control controller, 0...10 VDC – PTXPA Slim-Line SC cooker hood – Simple Control controller, 0...10 VDC – PTXPA Slim-Line SC cooker hood – Insulated attic floor penetration plate – Ceiling mounting plate Vallox 90 – Electric preheating unit max. 1000 W – Supply air filter F7 Power adjustment of ventilation Electrical connection 230 V, 50 Hz, 1.8 A (+ preheating unit 4.3 A) Class of protection IP 34 Weight Options Fans direct current (DC) Extract air Supply air Cross-counter flow cell, >80 % Seasonal damper G4 and F7 (F7 option) G4 52 kg Vallox SC 90

Upload: others

Post on 02-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    TECH

    NIC

    AL S

    PECI

    FICA

    TIO

    N

    VALLOX 90 SC RVALLOX 90 SC L

    Models:

    • Highly efficient heat recovery(� > 80%)

    • Energy-efficient integrated direct-current fans

    • 4-step Simple Control adjustment• Preheating with electricity (option)

    SC

    • 1.09.346F• 22.11.2012• Code A3521-1/2© VALLOX

    Code A3521-1/2

    Supply air

    Extract air

    92 dm3/s 50 Pa

    75 dm3/s 50 Pa0,119 kW 0,9 A

    0,119 kW 0,9 A

    Heat recovery

    Heat recovery bypass

    Filters

    – Simple Control controller, 0...10 VDC

    – PTXPA Slim-Line SC cooker hood

    – Simple Control controller, 0...10 VDC

    – PTXPA Slim-Line SC cooker hood

    – Insulated attic floor penetration plate

    – Ceiling mounting plate Vallox 90

    – Electric preheating unit max. 1000 W

    – Supply air filter F7

    Power adjustment of ventilation

    Electrical connection 230 V, 50 Hz, ≈ 1.8 A(+ preheating unit 4.3 A)

    Class of protection IP 34

    Weight

    Options

    Fans

    direct current (DC)

    Extract air

    Supply air

    Cross-counter flow cell, >80 %

    Seasonal damper

    G4 and F7 (F7 option)

    G4

    52 kg

    ValloxSC90

  • 687.

    7

    597

    82.6

    83.2

    160

    360.

    4

    157.5 157.2 117.2

    157.5 82.6

    83.2

    360.

    4

    157.2117.2

    160

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    VALLOX 90 SCDIMENSIONS AND MAIN PARTS

    22

    Main parts

    Extract air fan

    Supply air fan

    Preheating radiator (option)

    Measurement outlets

    Heat recovery cell

    Outdoor air filter F7 (option)

    1

    2

    3

    5

    6

    4

    7

    8

    9

    1010

    11

    12

    Outdoor air filter G4

    Extract air filter G4

    Summer / winter damper

    Summer / winter damper lock

    Safety switch

    Speed selector swich (option)

    Dimensions and duct outlets

    R MODEL

    1

    2

    Supply air to dwelling

    Extract air from dwelling

    Outdoor air to unit

    Exhaust air out

    3

    4

    Duct outlets, inner diameterof collar ø 125 mm

    L MODEL

    Measurement outlets

    Condensing water outlet

    The condensing water outletis located up in the backof the unit.

    Fastening brackets

    The fastening brackets arelocated up at the bottomof the unit.

    13 Connection box

    1

    2

    3

    4

    1

    2

    3

    4

    12

    Measurement outlets are located behind the machine plate. Detachthe machine plate by pushing it to the left and pull the outlets out.

    13

    Model R

    7

    11

    6

    2

    4

    5

    1

    10

    3

    9

    8

  • dm3/s

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    Air volumes

    SUPPLY / EXTRACT AIR VOLUMES / VALLOX 90 SCMeasuring points after the connectionoutlet.Fan curves indicate the total pressureavailable for duct losses.

    Extract airSupply air

    S

    E

    Sound power level from the ventilation unitto supply air ducts by octave band Lw, dB

    Medium

    frequency

    of the octave

    band, Hz

    ADJUSTING VOLTAGE/AIR FLOW

    Sound power level from the ventilation unitto extract air ducts by octave band Lw, dB

    ADJUSTING VOLTAGE/AIR FLOW

    ADJUSTING VOLTAGE/AIR FLOWS (supply/extract)

    A-weighted sound pressure level dB (A) comingfrom the unit through the envelope to the rooms wherethe unit has been installed (10 m2 sound absorption)

    63

    125

    250

    500

    1000

    2000

    4000

    8000

    LW, dB

    LWA, dB(A)

    Hz

    LpA, dB(A)

    VALLOX 90 SCPERFORMANCE

    3

    SFP (Specific Fan Power)guideline value < 2.5 (kw/m3/s)

    SFP=Input power (total) (W)Air flow (max) (dm3/s)

    Sound values

    Supply air, 2…10 VExtract air, 2…10 V Fan controlvoltage

    (V)

    Total inputpower

    W

    Pres

    sure

    loss

    in du

    cts. T

    otal

    pres

    sure

    Volume flow rate

    Pa

    0

    50

    100

    150

    200

    250

    300

    0 10 20 30 40 50 60 70 80 90 100 110

    VALLOX 90 SC

    3

    4

    4,5

    5,2

    6

    7

    8

    10

    9

    15

    22

    31

    47

    72

    114

    182

    3,6 V17/24 l/s

    5,4 V29/39 l/s

    7,3 V44/56 l/s

    10,0 V69/81 l/s

    23,9 30,6 38,0 45,3

    3,6 V16,5 l/s

    5,4 V27,2 l/s

    7,3 V40,9l/s

    10,0 V65,6 l/s

    61,7

    46,9

    39,6

    35,1

    31,1

    13,0

    61,8

    38,5

    67,2

    56,2

    47,0

    41,6

    38,7

    25,7

    15,6

    67,6

    46,1

    73,1

    64,3

    54,4

    48,6

    45,7

    34,4

    27,5

    20,0

    73,7

    53,3

    82,1

    73,4

    63,5

    57,3

    52,4

    43,5

    35,9

    22,6

    82,7

    61,9

    56,9

    46,4

    39,5

    32,7

    27,9

    17,6

    57,4

    36,4

    63,9

    53,9

    44,6

    38,8

    35,5

    24,5

    13,3

    64,3

    43,5

    69,6

    60,8

    52,2

    45,6

    43,2

    33,6

    23,2

    70,2

    50,5

    75,6

    69,1

    61,0

    53,3

    48,9

    42,9

    33,8

    76,7

    58,2

    3,6 V23,8 l/s

    5,4 V35,8 l/s

    7,3 V51,9 l/s

    10,0 V76,7 l/s

    S 3V

    E 3VS 4V

    E 4V

    S 4,5V

    E 4,5V

    S 5,2V

    E 5,2V

    S 6V

    E 6V

    S 7V

    E 7VS 8V

    E 8V

    S 10V E 10V

    EK

    SK

    SFP 1,5 kW/m3/s

  • © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    Selection of fan speedFan speed is selected by using a separate speed selector.Speed selectorThe speed selector can be used to select speeds 1, 2, 3 and 4:1. Use during absence. When the dwelling is empty, ventilation can temporarily be

    diminished.2-3. Normal use. In normal conditions air needs to be replaced once in two hours.4. Boosted operation. Cooking, bathing in the sauna or bathroom, drying clothes,

    using the toilet, having guests, overheat or a similar situation may cause a need forhigher than normal ventilation.

    If there is a cooker hood independent of the ventilation system in the dwelling, it is notnecessary to raise the speed of VALLOX 90 SC during cooking.

    Heat recovery bypassIn winter use the heat recovery cell of VALLOX 90 SC recovers heat from the air leaving thedwelling and uses it to heat the air coming from the outside.In summer use when it is warm outside, it is unnecessary to heat outdoor air. The heat recoverycell is bypassed in VALLOX 90 SC with the standard damper (A). The position of the dampercan be changed by opening the damper release (B) and then moving the damper in anotherposition. In the summer position air flow through the cell is prevented, and heat recovery bypassis activated.

    Air filteringVALLOX 90 SC features coarse filtering of both extract and supply air before the fans. Thesupply air side includes a G4 class coarse filter (C) and the extract air side a G4 class coarsefilter (D). The unit can also be equipped with a F7 fine filter (E), which captures fine dust andpollen as well dust not seen to the eye. The filters need to be in place in the unit wheneverventilation is in operation.

    DefrostingWater condensing from extract air may freeze in the heat recovery cell. Freezing can beprevented by stopping the supply air fan, or the unit can be equipped with a preheating resistor,which is switched on as needed.

    Stopping the supply air fanThe defrost thermostat T1 stops the supply air fan whenever the temperature of extract air isbelow +5 °C after the cell. The fan restarts when temperature has risen by circa three degrees,i.e. to 8 °C. The limit of the thermostat (F) can be adjusted at the back of the heat recovery cell.If the unit includes a preheating radiator (G), the supply air fan cannot be stopped.

    Outdoor preheatingThe unit can have been equipped with a preheating radiator at the factory. If that is the case,the defrost thermostat T1 switches the preheating radiator on whenever the temperature ofextract air goes below +5°C after the cell. The preheating radiator is switched off whentemperature has risen by circa three degrees to +8°C. The preheating radiator heats outdoorair before the heat recovery cell and prevents it from freezing. In very cold temperatures thepreheating radiator is not enough to heat maximum air flow to a sufficient degree (in atemperature of minus 30 degrees, maximum air flow is 30 dm3/s, which corresponds to speed2). The limit of the thermostat can be adjusted at the back of the heat recovery cell.

    F

    Preheatingradiator (G)(option)

    Note! The heatingradiator is tubularand can bescalding hot.

    Damper in summer position

    Damper in winter position.You can return the replacement damper tosummer position by pulling the releasedamper towards yourself.

    Speed selector

    G

    AB

    CD

    E

    G

    VALLOX 90 SCOPERATION

    24

    Defrost thermostat (F)First remove the heat recoverycell, then the cap protecting theadjusting screw of the thermostat.

    F

  • VALLOX 90 SC

    LED

    LED

    1000W

    1 210VDC- +

    950511

    1 2 3 4 5 6

    950511

    T1

    14

    BK

    YE RD BU

    E

    BL

    GY

    BK

    YE/G

    N

    BK BK

    YE/G

    NBU

    BN

    YE

    BU

    N

    11

    NL1 L

    1 N

    RDBU

    BN

    LS10 VDC N

    BK

    L27

    BL

    3x0,5

    NL (230 V)

    10A

    3 X 1.5 S

    KK

    S

    R1

    BN

    1 N 1 N

    BU

    YE/G

    N BU

    YE/G

    N

    BN

    9510

    49

    BN

    9510

    50

    NL

    K

    Vallox 90SC

    BN

    8 9

    3 X 1.5 S

    NL (230 V)

    10A

    KK

    Vallox 90 SC+

    Vallox 90 SC

    S

    S-

    PL 11

    12S 3 4

    10VDC+

    1 N

    GYBK BK

    BK

    9510

    2295

    1049

    9510

    50

    BN GY

    BK

    951016951016

    9510

    21

    -

    10VDC

    S10VDC

    -

    S-

    12 3 4

    -+

    S

    -+S

    LN

    OK

    S

    10VDC+

    OK

    -

    BU

    9509

    57

    951016951016

    - +

    - +

    950115

    WT BN

    GN

    9505

    2095

    0582

    BK

    9505

    17 B

    U950516 BU 950581 BU

    10 11 12

    L

    BUYE/G

    N

    T3 11

    12

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    ELECTRICAL DIAGRAMS

    5

    CONNECTION BOX(on top of the unit)

    SC cooker hood, e.g.PTXPA SC 600 Slim-Line

    4-speed SC cam switch

    4-speed SC cam switch or SC cooker hood

    S Supply air fanE Extract air fanK Safety switchKK Operating switchT1 Antifreeze thermostat

    Supply air fan stops at +4 °C(alternative connection)

    T3 Antifreeze thermostatPreheating radiator on at +5 °C

    R1 Preheating radiator (option), with 90 °Cand 130 °C overheat protection

    OK Voltage switch (in cooker hood)

    Wire coloursBU = blueBK = blackBN = brownWT = whiteGN = greenRD = redGY = greyYE/GN = yellow/green

  • VALLOX 90 SC

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    6

    CONTROL DIAGRAMDI

    STRI

    BUTIO

    NPA

    NEL

    10A

    230

    V 50

    Hz

    VALL

    OX 9

    0 SC

    INTE

    RNAL

    ELEC

    TRICA

    L AND

    CONT

    ROL C

    ONNE

    CTIO

    NS

    G4G4

    F7LP1

    HR

    H

    TS1

    EFM

    SILEN

    CER

    SILEN

    CERRE

    MOTE

    MON

    ITORI

    NG CO

    NTRO

    L CEN

    TRE

    OF TH

    E PRO

    PERT

    YCO

    NTRO

    L

    FAN

    SPEE

    D CO

    NTRO

    L SWI

    TCH

    S

    VENT

    ILATIO

    N ZO

    NE

    MSF

    6

    10A

    TS1

    M

    TS1

  • VALLOX 90 SC

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    Parts list VALLOX 90 SCCode Name Technical data Standard

    / Option

    G4 F7 Filter Supply air G4 + F7 (option) StandardExtract air G4

    H HR bypass damper Manual StandardHR Heat recovery cell Cross-counter flow cell, efficiency 80% StandardEF Extract air fan (DC – direct current) qv = 92 dm3/s (50Pa) StandardTS1 HR defrost thermostat Factory setting +5°C StandardSF Supply air fan (DC – direct current) qv =75 dm3/s (50 Pa) StandardS 4-step adjustment switch 1, 2, 3, 4 switch OptionLPl Preheating radiator PTC resistor max. 1.0 kW Option

    7

    DESCRIPTION OF OPERATION

    Control of operationPower supply to the unit can be controlled with the 0/1 switchin the distribution panel if needed. After starting, the unit operatesat the power selected on the fan speed control switch. There isalso a safety switch SS inside the unit. It stops power supply whenthe maintenance door of the unit is opened.

    Fan speed adjustmentCam switchThe SF and EF fans of the unit are controlled, depending onoperating conditions, with a separate 4-step SC cam switchlocated in the ventilation zone.

    Voltage signal controlThe fan power of the unit can be controlled steplessly with voltagesignal 0...10 VDC. With a voltage signal lower than 1.5 VDCthe fans stop.

    Heat recovery bypassSummer-time bypass (H) of the heat recovery cell HR is donemanually by turning the HR damper in the bypass position for thesummer.

    Heat recovery defrostingThe defrost thermostat TS1 of the HR cell stops the supply air fanSF, preventing the HR cell from freezing. The fan starts automaticallyas soon as the risk of freezing has passed. The operating point ofthe defrost thermostat cannot be changed, the factory setting is+5°C.The unit can alternatively be equipped with preheating radiatorLP1, controlled by antifreeze thermostat TS1. When there is a riskof frosting, preheating radiator LP1 starts to heat air coming fromoutside to the unit, thereby preventing the HR cell from freezing.The tubular preheating resistor is connected to 90°C (resetting)overheat protection and 130°C (not automatically resetting) overheatprotection.Note! The preheating radiator can be scalding hot, especially in winter.

  • VALLOX 90 SC

    © VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.

    Vallox Oy • Myllykyläntie 9-11 • FI-32200 Loimaa • Tel. +358 10 7732 200 • www.vallox.com

    LOCATION AND MOUNTING OF VALLOX 90 SC

    LOWER EDGEOF BRACKET

    1.09

    .346

    E/22

    .11.

    2012

    /PD

    F

    InstallationVALLOX 90 SC has to be mounted in a place wheretemperature does not fall below +10 ˚C. Without protectivecasing, the unit must be located in a place with no acousticdisturbance: storerooms, technical rooms etc.

    Wall mountingVALLOX 90 SC is mounted on the wall with a fixing plateas shown in the adjacent figure.Wall constructionWhen fixing the unit, take the wall structure into account.Because of sound conduction, avoid mounting the unit ona hollow, echoing dividing wall and on a bedroom wall; or,if you do, prevent sound conduction.

    Wall mounting plate

    Condensing waterThe delivery includes a water seal. With a pipe connected to the water seal,water condensing from extract air can be led to a floor drain (not straightto the drain).The pipe must not rise after the water seal. The unit has to be mounted levelwith the horizontal in order to ensure that condensing water can get out ofthe unit.

    Ceiling mounting/ceiling mounting plateFastening of ceiling mounting plate to ceilingThe ceiling mounting plate is mounted straight, and it has to befastened so that there is a space of circa 6 mm between the backedge of the ceiling mounting plate and the wall (Figure 1).Theventilation unit then becomes attached to the back wall.Minimum distance between the lower edge of the ceiling mountingplate and the ceiling of the room is 14 mm. With this distance,there will be a vent of circa 2 mm between the upper edge of themounted unit and the ceiling.The ceiling mounting plate is fixed to the ceiling with M8 threadbars. After the thread bars have been fastened to the ceiling, firstturn the nuts into the thread bars and lift the ceiling mounting platein place. Then push a rubber damper and washer to each threadbar, all the way into the cup of the plate, and turn the nut.Shorten the lower ends of the thread bars so that they will be atno more than 25 mm from the lower surface of the ceiling mountingplate. NOTE! Shortening the thread bars can only be done beforemounting the ceiling mounting plate. The maximum length of athread bar from the lower surface of the ceiling is the spacebetween the lower surface of the ceiling and the lower surface ofthe ceiling mounting plate + 25 mm.

    Figure 1

    Figure 2

    14 pcs

    NutsDamper rubber

    Lower surface of ceiling

    Washer

    ceiling

    wall

    LOCKING WINGS

    Mounting of ventilation unit to ceiling mounting plateBefore lifting the unit to the ceiling mounting plate, detach the following items from the unit(Figure 2):1. Thermostat knob (SC unit)2. Front panel (leave it hanging from the measurement hoses)Put the cables of the connection box into the slot in the upper part of the side plate and pullthe connection box next to the unit so that the cables remain in the slot. Make sure that theduct outlets for the unit’s extract air duct and for the duct coming from the outside to the unitare equipped with condensing water insulation. Lift the unit in place to the ceiling mountingplate till both locking wings lock to the outer edge of the side plate of the unit. Do a visualcheck of the tightness of the duct outlets and of the correct moving of the measurement hosesand electric cables. Fasten the front panel and the knob of the thermostat (SC unit) back inplace.

    at le

    ast 1

    4

    LOWER EDGEOF BRACKET

    THE LEAD-IN OF ELECTRICWIRES CAN BE DONE FROMBOTH SIDES OF THE UNIT.

    DURING MOUNTING THEUNIT RISES 10 MM HIGHERTHAN THE FINAL HEIGHT.

    Condensing water outletand water seal Silent Klick