Synthesis Report on the Viability of Micro-Generation Systems in Different Operational Contexts
Energy in Buildings and Communities Programme
October 2014
A Report of Annex 54 “Integration of Micro-
Generation and Related Energy Technologies in
Buildings”
Edited by
Maurizio Sasso (Università degli Studi del Sannio, Italy) – Subtask B Leader
Evgueniy Entchev (National Resources Canada, Canada) – Operating Agent
Peter Tzscheutschler (Technische Universität München, Germany) – Operating Agent
On behalf of IEA EBC Annex 54
![Page 2: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/2.jpg)
2
© Copyright: Copying with reference to “IEA EBC Annex 54 Integration of Micro-Generation and
Related Energy Technologies in Buildings” permitted.
All property rights, including copyright, are vested in Technische Universität München, Operating
Agent for EBC Annex 54, on behalf of the Contracting Parties of the International Energy Agency
Implementing Agreement for a Programme of Research and Development on Energy in Buildings and
Communities.
Published by Technische Universität München, Germany, 2014
Disclaimer Notice: This publication has been compiled with reasonable skill and care. However,
neither Technische Universität München nor the EBC Contracting Parties (of the International Energy
Agency Implementing Agreement for a Programme of Research and Development on Energy in
Buildings and Communities) make any representation as to the adequacy or accuracy of the
information contained herein, or as to its suitability for any particular application, and accept no
responsibility or liability arising out of the use of this publication. The information contained herein
does not supersede the requirements given in any national codes, regulations or standards, and
should not be regarded as a substitute for the need to obtain specific professional advice for any
particular application.
Citation: Maurizio Sasso, Giovanni Angrisani, Carlo Roselli, et.al.: “Synthesis Report on the Viability of
Micro-Generation Systems in Different Operational Contexts”, published by Technische Universität
München, Germany, 10/2014
Participating countries in EBC:
Australia, Austria, Belgium, Canada, P.R. China, Czech Republic, Denmark, Finland, France, Germany,
Greece, Ireland, Italy, Japan, Republic of Korea, the Netherlands, New Zealand, Norway, Poland,
Portugal, Spain, Sweden, Switzerland, Turkey, United Kingdom and the United States of America.
This document may be downloaded from: www.iea-ebc.org
![Page 3: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/3.jpg)
3
Synthesis Report on the Viability of Micro-Generation Systems in Different Operational Contexts
Energy in Buildings and Communities Programme
October 2014
A Report of Annex 54 “Integration of Micro-
Generation and Related Energy Technologies in
Buildings”
Authored by:
Maurizio Sasso, Giovanni Angrisani, Carlo Roselli, Francesco Tariello
(Università degli Studi del Sannio, Italy)
Antonio Rosato, Sergio Sibilio
(Second University of Naples, Italy)
Euy Joon Lee, Eun Chul Kang
(Korea Institute of Energy Research)
Soolyeon Cho
(North Carolina State University)
Evgueniy Entchev, Mohamed Ghorab, Kathleen Lombardi, Hajo Ribberink,
Libing Yang
(CanmetENERGY Research Centre, Canada)
Caterina Brandoni, Massimiliano Renzi, Alessio Mastrucci, Flavio Caresana,
Fabio Polonara
(Università degli studi e-Campus, Università Politecnica delle Marche)
Yoshiyuki Shimoda, Takuya Aoki
(Osaka University)
![Page 4: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/4.jpg)
4
Acknowledgements
This report is the result of an international project performed within Annex 54 of the IEA/EBC
programme. We would like to express our great appreciation to the participants of Annex 54 for their
contributions as well as for the support given by different national bodies.
The guidance of the EBC Executive Committee is gratefully acknowledged.
Maurizio Sasso (Subtask B Leader), Evgueniy Entchev, Peter Tzscheutschler (Operating Agents)
![Page 5: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/5.jpg)
5
Table of Contents
Acknowledgements ......................................................................................... 4
Table of Contents ............................................................................................ 5
1 Introduction .............................................................................................. 7
2 Review of Country-specific Simulations, Experimental, and Field Test
Studies ...................................................................................................... 9
2.1 Overview ................................................................................................................................................. 9
2.2 Japan ..................................................................................................................................................... 12
2.2.1 Summary .......................................................................................................................................... 12
2.2.2 Performance criteria used ............................................................................................................... 13
2.2.3 Description and characteristics of system components .................................................................. 13
2.2.4 Description of systems .................................................................................................................... 15
2.2.5 Results ............................................................................................................................................. 16
2.2.6 Conclusions ...................................................................................................................................... 16
2.3 Korea/Canada........................................................................................................................................ 17
2.3.1 Summary .......................................................................................................................................... 17
2.3.2 Thermal and Non-HVAC Electrical Loads of Studied Buildings ........................................................ 18
2.3.3 Performance of Load Sharing Systems ............................................................................................ 19
2.3.4 Results ............................................................................................................................................. 19
2.3.5 Conclusions ...................................................................................................................................... 20
2.4 Italy – Second University of Naples ....................................................................................................... 21
2.4.1 Summary .......................................................................................................................................... 21
2.4.2 Components, building, load profiles and reference system models ............................................... 22
2.4.3 Case studies ..................................................................................................................................... 25
2.4.4 Results ............................................................................................................................................. 25
2.4.5 Conclusions ...................................................................................................................................... 27
2.5 Italy – Università e-Campus, Università Politecnica delle Marche ........................................................ 28
2.5.1 Summary .......................................................................................................................................... 28
2.5.2 Buildings, load and external factors ................................................................................................ 29
2.5.3 Description and characteristic of system components ................................................................... 29
2.5.4 Description of systems .................................................................................................................... 29
2.5.5 Performance criteria ........................................................................................................................ 30
2.5.6 System cases and configurations ..................................................................................................... 31
2.5.7 Results and conclusions ................................................................................................................... 31
2.6 Italy – Università del Sannio .................................................................................................................. 32
![Page 6: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/6.jpg)
6
2.6.1 Summary .......................................................................................................................................... 32
2.6.2 Performance assessment procedure ............................................................................................... 34
2.6.2 Building, loads, and external factors ............................................................................................... 36
2.6.3 Description and characteristics of main system components ......................................................... 36
2.6.4 Results ............................................................................................................................................. 37
2.6.5 Conclusions ...................................................................................................................................... 38
2.7 Canada .................................................................................................................................................. 38
2.7.1 Method ............................................................................................................................................ 39
2.7.2 System description .......................................................................................................................... 39
2.7.3 Basis for results comparison ............................................................................................................ 41
2.7.4 Results ............................................................................................................................................. 41
2.7.5 Conclusions ...................................................................................................................................... 44
3 Review of Other Country-specific Results Deriving from the Microgen
III Conference .......................................................................................... 45
3.1 Germany ................................................................................................................................................ 45
3.2 United Kingdom .................................................................................................................................... 47
4 Conclusions ............................................................................................. 50
Terminology and Abbreviations .................................................................... 52
References .................................................................................................... 54
Background Information ............................................................................... 56
Annex 54 ........................................................................................................................................................... 58
![Page 7: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/7.jpg)
7
1 Introduction
The aim of Annex 54 “Integration of Micro-Generation and Related Energy Technologies in Buildings”
of the International Energy Agency is the analysis of the micro-generation performance in buildings.
Within this context, ‘micro-generation’ refers to different low-carbon technologies providing power,
heating, and/or cooling to buildings and/or district heating and cooling networks. These technologies
include combustion engines and fuel cell-based cogeneration and polygeneration systems, as well as
renewable-energy technologies. Micro-generation technologies can be deployed individually or in
combination (so-called hybrid systems).
Subtask B of Annex 54 mainly focused on the applications and performance assessment of
microgeneration in individual residences, multi-residences, and small commercial buildings. The
scope of the work was also expanded to encompass mobile energy systems such as plug-in hybrid
electric vehicles (PHEV) and more conventional EVs, as they can provide important flexibility through
demand-side management.
In the framework of Subtask B, contributing groups developed (mainly by simulation) a library of
country-specific simulations, experimental, and field-test studies, covering several technology types
and combinations, climatic conditions, and end-users. These studies evaluated the performance of
different microgeneration configurations (hybrid, poly-generation, etc.) within different operational
contexts: systems that are dimensioned/optimised and controlled using algorithms and optimisation
approaches developed within Subtask A of Annex 54 resulting in country-specific performance-
related data.
The aim of this report is therefore to highlight the main results of the microgeneration system-
performance assessments carried out in the country-specific studies, as well as in other analyses
developed by Annex 54 participating countries and presented at the Microgen III conference1.
This report is therefore divided in two main parts: in the first part (chapter 2), a review of the
country-specific simulations, experimental, and field test studies is performed, with the aim to
identify generic factors and performance trends (i.e., not country-specific) affecting the viability of
microgeneration systems. This review required the establishment of common reference points for
the comparison of performances, requiring agreement on common performance assessment
methodology and metrics, as defined in [1]. This report [1] provided a possible methodology, but
different valid and clearly defined approaches and criteria in the individual studies were chosen, as
well.
In the second part (chapter 3) are described the studies performed by Annex 54 participating
organisations and presented at the Microgen III conference. Finally, in chapter 4, some “common
rules of thumb” for the appropriate deployment of microgeneration technologies in buildings and
1Microgen III, the 3
rd International Conference on Microgeneration and Related Technologies, 15–17 April
2013, Naples, Italy.
![Page 8: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/8.jpg)
8
communities are identified, as derived in chapters 2 and 3. Other issues of microgeneration, such as
the impact on existing electrical systems and the optimal utilisation of microgeneration—
encompassing approaches to control, related technologies such as energy storage (including hybrid
vehicles), and demand-side control—are widely explored in [2].
![Page 9: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/9.jpg)
9
2 Review of Country-specific Simulations, Experimental,
and Field Test Studies
2.1 Overview
Six performance-assessment studies were developed by the following Annex 54 participating groups:
Japan
Korea/Canada
Italy – Second University of Naples
Italy – Università eCampus, Università Politecnica delle Marche
Italy – Università del Sannio
Canada
In Tab. 1 an overview of the devices, applications, criteria, and tools analysed within the country-
specific performance-assessment studies is reported. The most analysed microcogeneration device is
the internal combustion engine, followed by the different types of fuel cells (SOFC, PEFC, and
PEMFC). Only one study deals with the Stirling engine. Therefore, in all studies, natural gas is
considered as fuel. In terms of control of the cogeneration system, thermal following operation
mode is analysed in all reports, except in the study from Politecnica delle Marche that focuses on
economic and environmental criteria. The Second University of Naples investigated in addition the
electric following approach.
As regards other energy-conversion devices involved in the microgeneration system, almost all
studies introduce a thermal storage tank, in most cases a combined storage for domestic hot water
preparation and space heating. The auxiliary heater is a gas burner in all country-specific studies;
furthermore, the microgeneration system is connected to the electric grid to draw the shortage or to
sell the surplus, except in Japan where surplus electricity generated by cogeneration cannot be sold
to electricity utilities. For this reason, the electricity surplus is used for electric water heating in the
Japanese study.
A renewable energy technology is considered in three of the received contributions, namely solar
energy: solar collectors (NRC/CANMET), PV (Politecnicodelle Marche/e-Campus), and photovoltaic-
thermal (KIER). A cooling/heating device is considered in four studies, mainly an electric heat pump.
Thermally activated cooling systems are also considered: an absorption heat pump and a desiccant
wheel, investigated by Politecnico delle Marche/e-Campus and Università degli Studi del Sannio,
respectively. Mobile energy systems (plug-in hybrid electric vehicles) are investigated only by Second
University of Naples.
![Page 10: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/10.jpg)
10
Tab. 1: Overview of country-specific performance assessment studies
ST B Country specific performance assessment studies
NR
C/C
AN
ME
T
2nd
Univ
ers
ity o
f N
aple
s
Un
ive
rsità
deg
li S
tudi d
el S
ann
io
Osa
ka U
niv
ers
ity
KIE
R
Po
lite
cnic
o d
elle
Ma
rch
e/e
-Ca
mp
us
Coge
nsyste
m
Cogeneration devices
SOFC
PEFC
PEMFC
Stirling
ICE
Other
Fuel Natural gas
Other
Energy management,
Control
Electric following
thermal following
Economic criteria following
environmental criteria following
Oth
er
en
erg
y c
onvers
ion
syste
ms
Storage
domestic hot water (DHW) storage
Space heat storage
Combined storage DHW - space heat
Other
Auxiliary heater and electricity
Gas burner
Electric heating
Grid connected
Renewable Energy
Technology
Solar collectors
PV
Other
Cooling-Heating device
Absorption Heat Pump
Electric Heat Pump
Desiccant Wheel
Ground Source Heat Pump
Mobile energy systems
Plug-in Hybrid Electric Vehicles
![Page 11: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/11.jpg)
11
Tab. 2: Overview of country-specific performance assessment studies (continued)
Build
ing
Type
SFH
MFH
Small office building
Other
Energy level
Average
Low energy
Other
Heat (cold) distribution
Air heating/cooling
Bou
ndary
conditio
ns
Climate Climatic Zones
Electricity generation mix
Power Plant mix
Best Available Technology
Energy price Electricity
Fossil fuel
Crite
ria
Energy
Environmental
Economic
Tools
Simulation
TRNSYS
Matlab/Simulink
Other
Different types of buildings have been considered in the country-specific studies, almost equally
distributed between single-family homes (SFH), multi-family homes (MFH), and office buildings.
Average is the most diffused energy level, in terms of energy consumption of the building, with an air
heat/cold distribution system (namely fan coils and air handling units).
ST B Country specific performance assessment studies
NR
C/C
AN
ME
T
2nd
Univ
ers
ity o
f N
aple
s
Un
ive
rsità
deg
li S
tudi d
el S
ann
io
Osa
ka U
niv
ers
ity
KIE
R
Po
lite
cnic
o d
elle
Ma
rch
e/e
-Ca
mp
us
![Page 12: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/12.jpg)
12
The effect of climatic conditions on the investigated microgeneration system has been evaluated in
three country-specific studies, considering the installation of the system in different climatic zones. A
fixed location has instead been assumed in the other reports.
As regards the reference system based on separate production used for comparison purposes with
the performance of the microgeneration system, in most cases the “national power plant mix”
approach has been used. In two studies the best available technology is also used. In all studies an
energy performance of the system is performed, while the environmental and economic analysis is
missing in one and two reports, respectively. Finally, the most used simulation software is TRNSYS.
2.2 Japan
2.2.1 Summary
A performance assessment study was performed for a number of micro combined heat and power
(MCHP) generation systems in residential buildings in Japan [3]. The authors developed a residential
energy end-use simulation model in which the entire household stock is classified into several
categories according to a number of criteria that directly affect energy consumption. This model can
be used to estimate all of the demand profiles, including hot water and electricity, for each
household category, at five-minute intervals. Furthermore, household types are divided into detailed
categories in order to account for the variation among households. These features allow the
evaluation of the potential contribution of MCHP systems to energy conservation and global-
warming mitigation.
The strong focus on demand profiles is due to two considerable differences in the utilisation of
cogeneration between Japan and other countries, such as European countries:
surplus electricity generated by cogeneration can be sold to electricity utilities in Europe,
while this is not allowed in Japan;
the heat recovered from cogeneration can be utilised for both space heating and water
heating in Europe, but recovered heat can only be utilised for water heating in Japan. This is
because a central heating system is not usually employed in Japanese households.
These two restrictions on the utilisation of cogeneration in Japan need a careful attention to the
demand profile of households in the investigation of the performance of cogeneration; the energy,
economic, and environmental performance of cogeneration varies significantly with the demand
profile for electricity and heat.
The performance in terms of primary energy consumption, CO2 emission, and cost was analysed for
different cogeneration technologies already commercialised in Japan, namely natural gas-fuelled
internal combustion engines (MGE), polymer electrolyte membrane fuel cells (PEFC), and solid oxide
fuel cells (SOFC). Conventional systems and condensing water heaters (LHB) were also evaluated as
references.
These systems were examined for 19 household categories (that differ in number of household
members, family composition, and number of employed household occupants), 12 building types (6
![Page 13: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/13.jpg)
13
categories for detached houses and 6 categories for apartment houses, according to floor area), and
four different thermal insulation levels. It is concluded that the performance of the cogeneration
system strongly depends on household type (number of household members). The difference in the
primary energy saving among household categories for the PEFC and SOFC systems is large compared
to LHB and MGE systems. In particular, the energy-saving effect of PEFC strongly depends on
household type since the operation time is affected by the amount of hot water consumption.
SOFC generates about two-thirds of the total electricity consumption and shows the highest energy
reduction rate and CO2 reduction rate from the baseline, which is 14–20% in primary energy and 19–
23% in CO2 emission reduction rate for families with more than two members. PEFC generates
electricity smaller than SOFC and the energy saving ratio is affected by household types strongly.
2.2.2 Performance criteria used
The following indicators were used to evaluate the performance of the different MCHP systems.
Primary energy consumption
Electricity consumption is converted to primary energy consumption by considering the power
generation efficiency using a factor of 9,760 kJ/kWh. The HHV of natural gas and kerosene is directly
used to assess primary energy consumption.
CO2 emissions
CO2 emissions induced by energy consumption are calculated using the following emission factors
provided by the Japanese Ministry of Environment: 0.559 kgCO2/kWh for electricity, 50.8 kgCO2/GJ
for natural gas, 68.0 kgCO2/GJ for kerosene.
Cost
The economic performance of the MCHP system is evaluated as the net present value (NPV)
considering the initial cost of the cogenerator, the annual running cost reduction from baseline case,
and the discount rate (3%).
2.2.3 Description and characteristics of system components
Simulation models for conventional and cogeneration systems are developed. In these models, the
efficiency of each system is defined based on the manufacturer’s design value. Kuroki et al. [4] also
used design values and both values are compared.
Conventional water heaters
As a baseline for the study, conventional instant gas water heaters are used. The efficiency of a
conventional instant gas water heater is set at 78% as higher heating value (HHV). This reference
value is based on the approach of the national technological mix, as it represents the average
efficiency of conventional water heaters installed in Japan. If the baseline value changes — for
![Page 14: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/14.jpg)
14
example, it may increase because of a technological improvement of the installed units — the
calculation of the savings, in terms of primary energy consumption, CO2 emissions, and costs,
achieved by MCHP systems and the related overall conclusions should be updated.
Condensing gas water heater (LHB)
This unit employs a secondary heat exchanger to recover latent heat from the exhaust gas. The
thermal efficiency of such a system is 95%, based on HHV.
Micro gas engine cogeneration system (MGE)
The MGE consists of a micro gas engine power-generation unit, a waste heat-recovering water-
heating unit, an electricity resistance water heater, an auxiliary gas water heater, and a hot-water
storage tank. The MGE produces electric power and hot water using natural gas. The rated power
generation efficiency is assumed to be 23.7% and the waste-heat recovery efficiency is 59.3% ([4],
based on HHV). Since the generation efficiency of an MGE system decreases during part-load
operation, the MGE is generally operated at the rated capacity. When the electric power generated
by an MGE system is larger than the electricity demand of the house, the residual is used by the
electric resistance heater to generate hot water. The operation of an MGE system depends on the
hot water demand; when the hot water demand exceeds the production capacity of the MGE, an
auxiliary gas water heater makes up for the shortage. The model used for the MGE employs the same
conditions used for the systems described above. The power generation capacity is assumed to be 1
kW in the model.
Obviously, electric and thermal efficiencies of a MGE depend on the unit and its size; for example,
there are other MCHP devices based on natural gas-fired internal-combustion engines that have
electric efficiencies up to about 30%. Therefore, the results and the overall conclusion on the
feasibility of MCHP systems strongly depend on the investigated unit and its performance.
Polymer electrolyte fuel cell cogeneration system (PEFC)
A PEFC system consists of a reformer that transforms natural gas into hydrogen, a fuel cell that
generates electric power from hydrogen using a proton exchange membran, a water heating unit
that transfers the heat recovered from the fuel cell to the water, an electrical-resistance water
heater, an auxiliary gas water heater, and a hot-water storage tank. The rated power generation
efficiency is assumed to be 35.2%, while waste heat recovery efficiency is 50.6% (HHV). Kuroki et al.
[4] uses 33% and 45%, respectively. To extend the reformer lifetime, the PEFC is usually operated in a
daily start-and-stop mode at one of four output levels (25, 50, 75, and 100%) of the rated capacity.
The output level is determined by electric power demand. Similar to the MGE system, when the
electricity generated exceeds the electricity demand, the residual power is utilised by the resistance
water heater. When the amount of hot water produced is less than the hot water demand, the
auxiliary gas water heater makes up for the shortage. The model used for the PEFC follows the
operating conditions described for the systems above. The power generation capacity is 750 W. The
PEFC system is operated when the electricity demand exceeds 25% of the rated capacity of the PEFC.
![Page 15: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/15.jpg)
15
Solid oxide fuel cell cogeneration system (SOFC)
A SOFC system consists of a reformer, a fuel cell using an solid oxide or ceramic electrolyte, a waste
heat recovery unit, an auxiliary gas water heater, and hot-water storage tank. The SOFC is assumed
to have a power generation efficiency of 42%, which is higher than a PEFC, and a waste-heat recovery
efficiency of 39.2% (HHV). Kuroki et al. [4] used 41% and 36%, respectively. The SOFC is usually
operated in response to the demand for electricity due to a low heat-to-power ratio. The rated
power generation capacity is 700 W. Fig. 1 shows an example of the simulated daily operation of the
SOFC. The electricity generation follows the electricity demand and, because of the low hot-water
demand during the morning and afternoon, thermal energy accumulation increases until the very
high hot-water demand at about 20:00 when the storage tank is fully exploited.
0
0.5
1
1.5
2
2.5
3
0:00 6:00 12:00 18:00 0:00 6:00 12:00 18:00
Feb. 6 Feb. 7
Ele
ctr
icity d
em
and[k
W]
Ele
ctr
icity g
enera
tion[k
W]
0
5
10
15
20
25
30
35
40
Hot
wate
r dem
and[k
W]
Hot
wate
r accum
ula
tion[k
Wh]
Electricity demand Electricity generationHot water demnad Hot water accumulation
Fig. 1: Example simulation of daily SOFC system operation.
2.2.4 Description of systems
In Japan, hot water generated by micro-cogeneration and other water heaters is used for hot water
supply and also used for floor heating in many cases. However, only hot water supply is considered
as heat demand of micro-cogeneration and water heaters in this study. All electricity from
microcogeneration is assumed to be consumed in the residence. The heat loss ratio of all hot water
storage tanks used in this study is assumed to be 16% and that of the house supply pipes is assumed
to be 7%.
Electricity and gas tariffs, weather data, and annual primary energy consumption of the residential
sector of Osaka City (population: 2.6 million, households: 1.2 million) are used.
![Page 16: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/16.jpg)
16
2.2.5 Results
As an example of the obtained results, in Fig. 2 the total annual primary energy consumption for a
four-member family is shown.
-60
-40
-20
0
20
40
60
80
100
120
Ba
se
LH
B
MG
E
PE
FC
SO
FC
An
nu
al
en
erg
y c
on
su
mp
tio
n(G
J/y
ea
r/h
ou
se
ho
ld)
power generationgaselectricity
-60
-40
-20
0
20
40
60
80
100
120
Ba
se
LH
B
MG
E
PE
FC
SO
FC
An
nu
al
en
erg
y c
on
su
mp
tio
n(G
J/y
ea
r/h
ou
se
ho
ld)
power generationgaselectricity
Fig. 2: Total annual primary energy consumption for a four members family.
Negative value means power generation by micro-generation. Total energy consumption is shown as
a bold line. The SOFC generates about two-thirds of the total electricity consumption. It also shows
the highest energy reduction rate from the baseline, which is 15–20%. PEFC and MGE generate less
electricity than SOFC.
Fig. 3 shows the baseline total CO2 emissions for the residential sector of Osaka City. In addition, data
for the cases in which all of the households in Osaka City install LHB, MGE, PEFC, and SOFC systems is
also shown. Replacement of all of the water heaters with LHB systems reduces the total CO2
emissions by 4.4%. The CO2 reduction effects of cogeneration systems are 8.5% (MGE) to 17.3%
(SOFC).
2.2.6 Conclusions
From the Japanese country-specific performance assessment study, the following “rules of thumb”
can be derived:
The energy-saving effects of cogeneration differs with household type;
Optimal water heating systems exist for each household category, determining differences in
terms of primary energy, CO2 emission, and cost reduction;
SOFC systems have the highest energy and CO2 reduction potential. Large-scale introduction
of SOFC systems to Osaka city would markedly reduce the primary energy consumption
(12.3%) and CO2 emissions (17.3%);
To improve the feasibility of small-scale cogeneration systems, they need to be sized
according to the electric base load of the user; thus, the electricity is consumed on-site and is
![Page 17: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/17.jpg)
17
not exported to the grid. Furthermore, the electric and thermal energy demand and supply
profiles should adequately match (for example, as in Fig. 1) in order to minimise heat
dissipation from the storage tank and thermal integration from the auxiliary heater.
3,442 3,289 3,149 2,946 2,848
-3000
-2000
-1000
0
1000
2000
3000
4000
5000
Base LHB MGE PEFC SOFC
An
nu
al
CO
2 E
mis
sio
n[1
000 t
on
]
System
Power generation City gas
Electricity total
Fig. 3: Annual CO2 emission of the residential sector of Osaka City using the various cogenerations systems and water
heaters.
2.3 Korea/Canada
2.3.1 Summary
This work was developed in the framework of a joint project involving CanmetENERGY Research
Centre and Korea Institute for Energy Research (KIER) in which were analysed seven systems with
conventional, microgeneration, and renewable energy technologies for applications in residential
and commercial buildings [5]:
Case 1: a conventional setup — boiler and chiller to meet heating and cooling demands of a single
detached house (200 m2 floor area).
Case 2: the same conventional set up as Case 1 — boiler and chiller to meet heating and cooling
demands of an office building that has the same layout and floor area as the house in Case 1.
Case 3: a simple summation of Case 1 and Case 2 systems and loads.
Case 4: a load-sharing setup featuring a common boiler and chiller used to meet the combined loads
of both the house and office.
Case 5: a load-sharing case utilising a ground source heat pump (GSHP) to meet the combined loads.
![Page 18: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/18.jpg)
18
Case 6: a load-sharing case where a hybrid PEM fuel cell (FC)/ground source heat pump (GSHP)
system is used to meet the combined loads.
Case 7: a load-sharing case where a photovoltaic-thermal (PVT)/ground source heat pump (GSHP)
system is used to meet the combined loads.
As an example, the more complex system (case 7) is shown in Fig. 4.
House3 Way valve
Fan Coil Unit
n
i
Load
1
n
i
Demand
1
Main Pump
Flow meter
3 Way valve
GHX
Natural Gas
Desuperheater
GSHP Pump
Cold Water
Tank
DHW for House and Office
T
T
T
T
City Water
PVT
Inverter
DC AC
Hot Water
Tank
PVT Pump
Office
GSHP
GS Tank Pump
Solar Tank
Cir. Pump
Solar Preheat
Tank
House3 Way valve
Fan Coil Unit
n
i
Load
1
n
i
Demand
1
Main Pump
Flow meter
3 Way valve
GHX
Natural Gas
Desuperheater
GSHP Pump
Cold Water
Tank
DHW for House and Office
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
TT
TT
TT
City Water
PVT
Inverter
DC AC
Hot Water
Tank
PVT Pump
Office
GSHP
GS Tank Pump
Solar Tank
Cir. Pump
Solar Preheat
Tank
Fig. 4: Layout of case 7.
Detailed simulation models were developed to better understand the performance of different
system designs and layouts under various weather conditions and occupants’ behaviour by means of
the “TRaNsient Systems” (TRNSYS-17) software platform. Component models were selected from the
TRNSYS libraries and enhanced with latest manufacturer’s system-performance data. Additional
models were developed for those components that are not present in the TRNSYS libraries, such as
PEMFC (Proton Exchange Membrane Fuel Cell), GSHP (Ground Source Heat Pump) desuperheater,
etc. The models were run with Ottawa (Canada) and Incheon (Korea) weather data over a year to
simulate and analyse the energy systems’ performance while satisfying the buildings heating and
cooling demands. Besides that, “Energy Plus” was also used as another commercial software to
model and analyse these cases.
2.3.2 Thermal and Non-HVAC Electrical Loads of Studied Buildings
Both thermal and non-HVAC electric loads of the two buildings (residential and office) were analysed
through appropriate time-series methodology. The house and office were assumed to be separated
from each other with no thermal interaction between them. Both buildings have identical geometries
with floor area of 200 m2 and are assumed as a single interior zone for the simulations. Detailed
building models were developed using typical Canadian house/office heating and cooling loads. The
domestic hot-water consumption for the house and office were based on ASHRAE-124
recommendations for residential and office building. Non-HVAC electrical load profiles in 15-min
![Page 19: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/19.jpg)
19
intervals for weekdays and weekends were generated for both the house and office based on the
“average” consumption of a detached house used for a residential or office purpose in Canada.
2.3.3 Performance of Load Sharing Systems
While the thermal loads occur in the evening through the early morning in residential houses, the
thermal loads in offices happen during the daytime. The two thermal loads have opposite profiles. In
general, the separated systems are operated at very low partial-load conditions during the day for
houses and during the evening for offices. By combining the two opposite loads, the peak thermal
demand could be reduced and, as a result, the initial capital cost could be reduced considerably.
Moreover, the load sharing system could be operated at higher part load ratios. However whether
the load sharing system could result in energy use reduction compared to the separated systems
depends on the performance characteristics of the HVAC equipment. Simulations and analyses were
carried out to investigate the benefits of the load sharing, as well as the impact of equipment
performance characteristics on system energy uses and savings.
2.3.4 Results
The energy-consumption analysis results for the seven case studies are summarised in Tab. 3. The
following are summaries drawn from the energy analysis and comparisons between the three load-
sharing systems, the hybrid renewable energy systems, and the Reference System.
The consumption of the load-sharing system with separate “production” (Case 4, natural gas boiler +
electricity grid) is 173 kWh/m2 less than that consumed by the Reference Case 3 (178 kWh/m2); that
is a 3% operational energy savings, which mainly resulted from higher equipment efficiency, better
partial load performance, as well as less pump and fan energy consumption.
The simulation results for the load-sharing system with GSHP able to meet both thermal and cooling
loads (Case 5) showed a total energy consumption reduced to 106 kWh/m2 and an overall energy
savings of 40.6% due to the introduction of a significant renewable component. The net energy
consumption is reduced to 132 kWh/m2 for the hybrid GSHP-PEMFC system (Case 6), with an overall
energy savings of 25.8%. The net energy consumption was further reduced to 77 kWh/m2, the lowest
among all the case studies, for the GSHP-PV/T system (Case 7). Compared to the conventional system
(Case 3), this indicates an overall energy saving of 56.6% due to the contribution of both geothermal
and solar renewable energy.
Further analysis revealed that even higher operational energy savings (15–20%) can be achieved for
the load-sharing application with optimal system sizing and appropriate implementation of control
strategies. Significant capital cost savings (20–25%) are also apparent; these are due to the reduced
equipment size and the optimal distribution and utilisation of system layout. The study on the effect
of buildings’ U-values and climate on building thermal loads showed that, for the same building
specification, the heating and cooling loads under Incheon (Korea) weather conditions are about 0.53
and 1.3 times, respectively, in comparison to Ottawa (Canada) weather conditions.
![Page 20: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/20.jpg)
20
Tab. 3: Annual Energy Consumption, Production and Savings in kWh for Cases 1–7
Energy Use (kWh/m2 -yr) Case 1 Case 2 Case 3
(Reference)
Case 4 Case 5 Case 6 Case 7
Space Heating +
DHW Heating
Natural Gas 133 97 115 111 5 1 56
Electricity - - - - 31 30 28
Space Cooling
Electricity 7 10 8 7 6 6 6
Non HVAC (lighting, equip., etc.)
40 52 46 46 46 46 46
Fans 6 7 7 7 7 7 7
Pumps 3 2 3 2 11 10 6
Electricity Production 0 0 0 0 0 -22 19
Total (Net) End Use 189 168 178 173 106 132 77
Energy Saving 5 72 46 101
Energy Saving (%) 3.0% 40.6% 25.8% 56.6%
2.3.5 Conclusions
The first aim of the project was to model and simulate seven systems with conventional and
renewable energy technology for single residential and commercial buildings. The aim was to gain a
better understanding of the performance of different system designs and layouts under various
weather conditions and occupants’ behaviour.
The systems were modelled and simulated with Ottawa, Canada weather data for one year using
“TRNSYS” software platform for individual and load-sharing case studies. The first and second cases,
for the house and office, respectively, use a boiler and a chiller to meet heating and cooling load
demands. Case 3 is a simple sum of case 1 and 2 for thermal load and energy consumption. Case 4
used a single-unit boiler and chiller to satisfy the combined thermal demands of the house and office.
Case 5 investigated the integration of GSHP system with load sharing. In case 6, a hybrid
microgeneration system (GSHP–FC) is studied in a load-sharing application. Finally, case 7 is a load-
sharing case where a photovoltaic-thermal (PVT)/ground source heat pump (GSHP) system is used to
meet the combined loads.
Besides the results listed in the previous section, the following main conclusions can also be derived
from this study:
In a simple summation of the different loads of the building, aimed at characterising its
overall energy consumption and the different contributions, not taking into account any
![Page 21: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/21.jpg)
21
conversion method (such as exergy-based evaluations), space-heating load accounted for the
largest share of the total building loads with more than 50% for the house and combined
(house + office) and close to 50% for the office. The non-HVAC electrical load was the
second, followed by the cooling load, and then the DHW load for the house, office, and the
combined house and office.
The total thermal load for residential and commercial buildings is 154 and 126.4 kWh/m2,
respectively, and 139 kWh/m2 for load sharing.
Compared to the Reference Case (Case 3), the load-sharing Case 4 reduced the boiler and
chiller capacities by 18% and 25%, respectively. Hence, the initial capital cost could be
reduced significantly because of both equipment quantity and capacity reduction.
The “Energy Plus” simulation results showed a peak heating load reduction of 21% and a
peak cooling load reduction of 19% compared to the simple sum of Case 1 and Case 2 (i.e.,
Case 3). The annual heating and cooling energy savings were 15.9% and 14.6%, respectively.
Spreadsheet modelling showed that the most efficient microgeneration configuration is PVT-
GSHP which consumes only 37.8 kWh/(m2·y).
2.4 Italy – Second University of Naples
2.4.1 Summary
This work examines the performance of a residential building-integrated microcogeneration system
(alternative system) during the heating season by means of building simulation software (TRNSYS),
considering the transient nature of building- and occupant-driven loads as well as the partial-load
characteristics of the cogeneration unit [6].
The alternative system was based on a natural gas-fuelled reciprocating internal combustion engine-
based cogeneration unit (MCHP) with 6.0 kW as rated nominal electric output and 11.7 kW as rated
nominal thermal output. Auxiliary thermal energy was supplied by a natural gas-fired boiler; the heat
provided by both the MCHP device and the boiler was accumulated within a storage tank. The
cogeneration system supplied thermal and electric energy to a multi-family house composed of three
floors, compliant with the transmittance values of both walls and windows suggested by Italian Law.
In order to evaluate the influence of the climatic conditions, the analyses were performed by
considering the multi-family house located in four different Italian cities (Palermo, Napoli, Roma, and
Milano), representative of the different Italian climatic conditions. In addition, a parametric analysis
was performed to evaluate the effect of the tank size on the system performance: three different
hot-water storage volumes were investigated.
As the economic viability of the cogeneration unit strongly depends also on the economic value of
the cogenerated electricity, the system operation was also evaluated by considering two different
electric demand profiles: first, the operation of lighting systems and other domestic appliances was
considered, while in the second the electric consumption associated with the overnight charging of
an electric vehicle was further added.
![Page 22: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/22.jpg)
22
The energy, environmental, and economic sensitivity analysis were performed with both electric and
thermal load-following control strategies of the MCHP. The simulated performance of the MCHP was
compared with the performance of a conventional system consisting of a natural gas-fired boiler and
to the national electric grid.
2.4.2 Components, building, load profiles and reference system
models
Each component of the whole system was simulated using the software “TRNSYS”, where each piece
of equipment is modelled with a component named “type.”
MCHP unit
The reciprocating internal combustion engine-based micro-cogeneration unit commercialised by the
AISIN SEIKI company was investigated in this study. The main characteristics of this device are
reported inTab. 4.
Tab. 4: Main characteristics of the investigated MCHP unit
Model AISIN SEIKI unit GECC60A2 (NR-P)
Engine type Reciprocating internal combustion engine, water cooled, 4 cycles, 3 cylinders
Displacement 952 cm³
Speed revolution 1,600–1,800 rpm
Fuel Natural gas, LPG
Generator type Permanent-magnet type, synchronous generator 16 poles
Rated electric output 0.3–6 kW
Heat recovery rate 11.7 kW
Operating sound at 1.0 m distance and 1.5 m height 54 dB
Electric efficiency at maximum load 28.8 %
Thermal efficiency at maximum load 56.2 %
The cogeneration unit was simulated by using the detailed dynamic model developed within Annex
42 of the International Energy Agency [7],[8]. This model is designed to predict primary power
consumption, electric power generation, thermal output, coolant outlet temperature, etc., during
both steady-state and transient operation. It was calibrated and validated on the basis of laboratory
tests performed by the authors at the Built Environment Control Laboratory of the
SecondaUniversitàdegliStudi di Napoli (Italy).
![Page 23: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/23.jpg)
23
Hot water storage
The combined tank for both heating purposes and domestic hot-water production was modelled in
this study by means of the “type60f.” The tank is divided into N fully-mixed equal sub-volumes; for
each sub-volume, mass and energy balances are considered in a transient state, allowing one to be
used to calculate thermal stratification in the component. In this study, ten nodes were used in the
tank; a uniform tank loss coefficient per unit area equal to 3.0 kJ/(h·m2·K) was assumed.
A vertical cylindrical hot water storage unit with one flow inlet (from the building) and one flow
outlet (towards the fan-coils) was considered. The tank is equipped with three internal heat
exchangers: the lower one is connected to the MCHP, the upper one is connected to the natural gas-
fired, the third one is used for domestic hot-water production.
Taking into consideration that the selection of the tank volume is very important to optimise the
plant performance, its optimal value was determined by carrying out a sensitivity analysis; the whole-
system operation with three different commercially available hot-water storages characterised by
different sizes were considered: TANK1=0.855 m3; TANK2=0.738 m3; TANK3=0.503 m3.
Boiler
A 20.0-kWth natural gas-fired boiler was considered in this study. The boiler was modelled in TRNSYS
by using the “type6” included in TRNSYS library. It is activated only if the water temperature within
the tank is lower than 55°C, or when the domestic hot water temperature is lower than 45°C.
The boiler efficiency is evaluated by means of a linear interpolation of the manufacturer data (0.927
at rated output, 0.924 for a part load ratio equal to 30%).
Building
The layout of the building is a multiplication of a single-family house type building geometry. The
main geometrical characteristics of each floor and the building orientation are shown in Fig. 5. All
three floors have the same useable floor area (96.0 m2), while the net height of each floor is 3.0 m.
The threshold values of transmittance for both walls and windows of renovated buildings were
assumed depending on the climatic zone and the wall type. Italian Law specifies the duration of the
heating season depending on the climatic zone; according to this, the system was simulated with a 1-
min time step for the heating period corresponding to each city. Fan coils are installed into the
building in order to balance the space-heating sensible load. Heat coming from occupants, personal
computers and lighting systems was assumed to contribute to the internal gains of the building.
The “type56a” was used for modelling the building envelope, indoor air set-point temperature,
infiltration, and internal gains. “Type15-6” was used for reading the external “Energy Plus” weather
data files of the four above-mentioned cities.
![Page 24: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/24.jpg)
24
B e d ro o mB e d ro o m
L iv in g ro o m
K itc h e n
B a th ro o m
W 2
W 3
W 4
W 5
W 1
1 2 .0 m
8 .0 m
Windows area:
W1 = 2.23 m2
W2 = 1.04 m2
W3 = 2.75 m2
W4 = 1.82 m2
W5 = 3.00 m2
Fig. 5: Main geometrical characteristics of a single flat of the whole multi-family house.
Domestic hot water and electricity demand profiles
The domestic hot-water demand profile with an average basic load of 200 l/day in the time scale of 1
minute was used for estimating the demand of each single flat, according to the load profiles defined
within IEA-SHC Task 26.
The electric consumption of each appliance was derived from a domestic electricity demand model
developed at Loughborough University (UK). The electric consumption associated to the overnight
charging of an electric vehicle was derived from data provided by a manufacturer. The electricity
consumption of auxiliaries (fans and pumps) was also taken into account.
Reference system
A 32.0 kWth natural gas-fired boiler was considered for the thermal energy production within the
reference system. The boiler efficiency is evaluated by means of a linear interpolation of the
manufacturer data (0.937 at rated output, 0.911 for a part load ratio equal to 30%). Concerning the
efficiency of the centralised power plants connected to the national electric grid, a figure of 0.461
was assumed that represents the power-plant average efficiency in Italy, including transmission
losses.
![Page 25: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/25.jpg)
25
2.4.3 Case studies
Tab. 5 shows the 32 simulated case studies.
Tab. 5: Simulated case studies
Case number Electric demand profile
City MCHP control strategy
Tank volume [l] (liters)
Case 1
without overnight charging of an electric vehicle
Palermo
Electric load-following
855
Case 2 738
Case 3 503
Case 4 thermal load-
following
855
Case 5 738
Case 6 503
Case 7
Napoli
Electric load-following
855
Case 8 738
Case 9 503
Case 10 thermal load-
following
855
Case 11 738
Case 12 503
Case 13
Roma
Electric load-following
855
Case 14 738
Case 15 503
Case 16 thermal load-
following
855
Case 17 738
Case 18 503
Case 19
Milano
Electric load-following
855
Case 20 738
Case 21 503
Case 22 thermal load-
following
855
Case 23 738
Case 24 503
Case 25
with overnight charging of an electric vehicle
Palermo Electric load-following
855
Case 26 thermal load-following Case 27 Napoli Electric load-following Case 28 thermal load-following Case 29 Roma Electric load-following Case 30 thermal load-following Case 31 Milano Electric load-following Case 32 thermal load-following
2.4.4 Results
As an example of the obtained results, the values of FESR (Fuel Energy Saving Ratio) as a function of
the city, the MCHP control logic, and the electric demand profile are shown in Fig. 6.
![Page 26: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/26.jpg)
26
-28
-24
-20
-16
-12
-8
-4
0
4
8
Palermo
Napoli
Roma
Milano
-24.0-23.0
-25.3-23.5
-18.8
-18.8
-20.0-19.2
3.1 6.5
2.36.5
2.4 5.7
1.75.9
MCHP control logic
PE
S (
%)
City
Electric load-following
WITHOUT electric vehicle
charging
Electric load-following WITH
electric vehicle charging
Thermal load-following
WITHOUT electric vehicle
charging
Thermal load-following WITH
electric vehicle charging
Fig. 6: Values of FESR as a function of city, MCHP control logic, and electric demand profile.
It is noted that:
the values of FESR are always negative in the case of electric load-following logic and positive in the
case of thermal load-following logic;
the overnight electric-vehicle charging allows for significant increase of the values of FESR in the case
of electric load-following operation, while it reduces the values of FESR in the case of the thermal
load-following operation;
for the best condition (thermal load-following operation without the electric-vehicle charging), the
maximum value of FESR is obtained when the building is located in Napoli or Milano;
for thermal load-following operation with the electric-vehicle charging, the maximum value of FESR is
obtained when the building is located in Milano;
In Fig. 7, the CO2 equivalent emissions of the alternative system during the whole heating season, as
a function of the tank volume (TANK1, TANK2, TANK3), the city, and the MCHP control logic are
reported; the electric demand profile without the overnight charging of the electric vehicle was
considered.
The tank with the largest volume (TANK1) allows for minimising the CO2 equivalent emissions of the
alternative system, while the tank with the intermediate volume (TANK2) provides the maximum
pollutant emissions. In the case of electric load-following operation, the operation with TANK1 allows
the system to achieve a percentage reduction ranging from 3.6% (Palermo) up to 4.7% (Milano) if
compared with TANK2. In the case of thermal load-following operation, the operation with TANK1
allows the system to achieve a percentage reduction of emissions ranging from 9.1% (Napoli) up to
![Page 27: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/27.jpg)
27
15.7% (Milano) if compared with TANK2. The thermal load-following logic gives lower values of
carbon dioxide equivalent emissions in comparison to the electric load-following control strategy.
4.0E+03
6.0E+03
8.0E+03
1.0E+04
1.2E+04
1.4E+04
1.6E+04
TANK1 - Electric load-
following operation
TANK2 - Electric load-
following operation
TANK3 - Electric load-
following operation
TANK1 - Thermal load-
following operation
TANK2 - Thermal load-
following operation
TANK3 - Thermal load-
following operation
Palermo
Napoli
Roma
Milano
Fig. 7: Values of CO2 equivalent emissions as a function of tank volume, city, and MCHP control logic.
A similar analysis is also performed in terms of economic performance, considering the operating
costs due to both natural gas and electric energy consumption, the tax rebate on natural gas
purchased for high-efficiency MCHP systems, as well as the revenue from selling the electric energy
surplus.
2.4.5 Conclusions
From this Italian country-specific performance assessment study, the following “rules of thumb” can
be derived:
the hot water tank with the largest volume allows the cogeneration unit to operate more
continuously, reducing the inefficiencies related to the occurrence of transient behaviour
during start-up and shutdown. Therefore, the total primary energy consumption, the
equivalent carbon dioxide emissions, and the operating costs of the alternative system are
minimised;
the microcogeneration system allows for both an energy saving and a reduction of carbon
dioxide equivalent emissions in comparison to the reference system only in the case of
thermal load-following logic;
![Page 28: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/28.jpg)
28
the microcogeneration system is more convenient than the conventional system from an
economic point of view (operating costs);
the electric demand profile including the overnight charging of the electric vehicle provides
better results of the MCHP in terms of energy, environmental, and economic performance in
comparison to the electric demand profile without the overnight charging of the electric
vehicle only when the MCHP unit is operated under electric load-following logic;
under thermal load-following logic, the best results are obtained when the building is located
in the coldest city (Milano), regardless of the electric demand profile.
2.5 Italy – Università e-Campus, Università Politecnica delle
Marche
2.5.1 Summary
This work dealt with the performance assessment of a hybrid micro combined cooling heat and
power (MCCHP) system, consisting of a variable speed ICE cogenerator and a high concentrator
photovoltaic (HCPV) system [9]. This solution provides advantages in terms of operating costs,
carbon dioxide emissions, and primary energy consumption if compared to separate production and,
in specific working conditions, also compared to the single usage of MCCHP and solar-power systems.
The hybrid system was applied to representative public buildings of a small urban area in Central
Italy: Corinaldo. Three building typologies have been considered in the analysis: office buildings,
school buildings, sport facilities.
Since several factors influence the performance of hybrid micro-CCHP applications, such as weather
condition, fuel, and electricity prices; an optimisation approach for the management of the entire
system has been followed, with the aim to maximise energy, environmental, and economic savings.
In detail, the performance analysis has involved the following steps:
1) building dynamic simulation analysis to assess hourly thermal and cooling profiles;
2) hourly assessment of building electrical loads on the basis of electricity bill and typical load
profiles defined in the literature;
3) assessment of hybrid system-operation parameters following a multi-objective optimisation
approach that pursues the minimisation of three items: i) operating costs, ii) carbon dioxide
emission, and iii) primary energy consumption, on the basis of weighting factors defined ‘a
priori’;
4) post-processing of operation parameters to calculate the indexes required by the 3-E
performance analysis — Energy, Economic and Environmental, ([1], section IV.1);
5) fulfilment of a sensitivity analysis to assess the influence of the main design parameters on
the results.
![Page 29: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/29.jpg)
29
2.5.2 Buildings, load and external factors
Numerical simulations were performed in a dynamic state with the “Energy Plus” software of the US
Department of Energy. A virtual model was developed for each building under analysis in order to
determine heating and cooling loads. A typical load profile on was determined an hourly basis for
each month by simulating one full representative day in terms of climatic conditions and building
operation schedule.
Input data included climatic data records of the location on an hourly basis, the geometry of the
building, characteristics of the building envelope, and HVAC systems and operation schedules.
Output hourly profiles of net heating and cooling demand were compared with measured monthly
consumption data for each building in order to check the reliability of the simulation tool.
2.5.3 Description and characteristic of system components
In order to assess the hybrid system, both HCPV and ICE have been modelled in the
“Matlab/Simulink” environment by describing all the subsystems which compose the ICE (such as the
engine and the heat exchangers) and the HPVC (the triple junction photovoltaic cell, the optics, and
the tracking mechanism).
2.5.4 Description of systems
Fig. 8 shows the conceptual layout of the hybrid MCCHP system that was analysed. It has been
designed with the aim to maximise the plant flexibility. The system comprises a MCHP based on an
ICE, a HCPV unit, a thermal energy storage (TES), an additional heating boiler, an absorption chiller
(ABHP), and a vapour compression chiller (EHP). Both micro-CHP and HCPV systems are connected in
parallel to the grid and to the end user. The thermal demand can be satisfied either by the additional
heating boiler, or by the thermal power recovered from the ICE, or by the thermal power stored in
the TES. The cooling demand can be satisfied either by the vapour compression chiller or by the
absorption chiller.
Since energy, economic, and environmental performance of hybrid systems depend on several
parameters such as fuel tariffs, purchasing and selling price of electricity, ambient conditions, and
energy loads, an optimisation approach is needed to correctly assess the potential of the
introduction of hybrid systems. The algorithm developed follows a multi-objective approach, aiming
at minimising operating costs, primary energy usage, and carbon dioxide emissions.
For the calculation, all three objectives have been expressed on a cost basis and weighting factors
have been defined ‘a priori.’ Finally a sensitivity analysis has been conducted to understand the
influence of the defined weighting factors. The objective function is given by the yearly weighted
sum of operating costs, primary energy consumption cost, and CO2 emissions cost.
![Page 30: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/30.jpg)
30
Fig. 8: Diagram of the system analysed in this study.
2.5.5 Performance criteria
In order to assess the hybrid MCCHP system (defined as the alternative system, AS) from an energy
point of view, the primary energy saved with respect to the conventional system (CS: electric grid,
gas boiler, space cooling) is calculated by means of the fuel energy saving ratio [1]. For the case
under analysis, Fig. 8, it can be written as:
CS
GridEl
CS
GBFuel
AS
GridEl
AS
GBFuel
AS
CGUFuel
PEDE
PEDEDEFESR
1
The index used to assess the hybrid system from an environmental point of view is the global CO2
emission reduction. It is a comparison of the CO2 emissions of the hybrid system with emissions of
the conventional system.
The index used to assess the hybrid MCCHP system from an economic point of view is the simple
pay-back period. For the case under analysis the extra investment cost of the alternative system is
given by the cost of the combined heat and power unit, the high concentrator photovoltaic system,
and the absorption chiller.
The operational cost of the AS is given by the sum of fuel cost of running MCHP unit, electricity
bought from the grid, fuel cost of feeding the gas boiler to satisfy the thermal demand when not
![Page 31: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/31.jpg)
31
covered by the MCHP, and operating and maintenance cost of the MCHP system. It is necessary to
subtract from the operational costs the revenues coming from selling the electricity produced by the
power unit and not used by the user.
2.5.6 System cases and configurations
In order to assess the system performances and advantages derived from hybrid applications, instead
of comparing the hybrid system to a conventional system (baseline case), two other configurations
have been analysed: the single cogeneration unit and the solar power unit. Fig. 9 shows a sum of all
the studied configurations, considering both the alternatives (A, B, C) and conventional (D) ones.
2.5.7 Results and conclusions
The main outline of the work is:
hybrid system configurations provide energy and environmental benefits of about 40%
compared to conventional systems;
hybrid system energy performance is better than the single use of MCHP and HCPV; the
advantage increases when the number of MCHP operating hours increases;
assuming the same weight to energy ratio and environmental and economic criteria, the ICE
works in thermal priority in order to maximise the primary energy savings, and thus reduce
CO2 emissions;
the economic performance of the system deeply depends on the specific ratio between
thermal and electric load, rather than energy prices. A limited thermal load reduces the
number of operating hours of the ICE, which penalises the return on investment. In this case,
the combination of two low-carbon systems with respect to a single system is not justified;
as regard the HCPV, the high investment cost could be better recovered in regions
characterised by a higher value of the direct component of the solar radiation;
the introduction of the hybrid system strongly cuts the operating cost from a minimum of
35% up to 60%. The advantages are particularly meaningful when there is a higher thermal
demand throughout the year, which increases the operating hours of the MCHP unit;
the main problem in the adoption of this type of technology is the high capital investment
cost, which can be recovered only in some cases;
in none of the case studied does the optimal algorithm recommend the absorption chiller.
The electric energy produced by the HCPV system, which is strongly correlated to the end-
user demand, can be used more efficiently to feed a vapour compression chiller that has a
higher COP than the absorption systems;
the adoption of hybrid MCCHP by Public Administrations provides a reduction of public
expenditure and an exemplary action to promote carbon dioxide emission reduction. At the
same time, specific financing mechanisms should be promoted in order to overcome the
![Page 32: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/32.jpg)
32
problem related to high investment costs such as third-party financing and a favoured access
to national and international government funding.
Fig. 9: Diagrams of the configurations analysed in this section.
2.6 Italy – Università del Sannio
2.6.1 Summary
A system (alternative system, AS) is analysed consisting of a small-scale trigeneration system in which
a heat-led microcogenerator interacts with a desiccant-based air handling unit (AHU), equipped with
![Page 33: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/33.jpg)
33
a silica-gel desiccant wheel (DW). The system provides the air-conditioning service to a lecture room
during summer and winter periods.
CHILLER
MCHP
MCHP
FuelPE
DW
MCHP
ElOE
DCS
CoolNE
AHU
COOLING
COIL
CO
OL
ING
EN
ER
GY
EL
EC
TR
IC
EN
ER
GY
HEATING
COIL
process
section
regeneration
section
Process
air
Regeneration
air
auxiliaries
DH
W
STORAGE
TANK
BOILER
MCHP
ThOE
MCHP
ElNE
DHWST
ThNE
GB
FuelPE
GB
ThOE
chil
CoolOE
HCST
ThOE
ST
ThOE
auxMCHP
ElOE
chilMCHP
ElOE
MCHP
El
MCHP
Th
MCHP
FuelOEOEPE
Fig. 10: Main energy flows of the trigeneration system during summer operation.
During the summer season, the AHU operates as a desiccant cooling system (DCS) and the DW
balances the latent load of the process air while an electric chiller manages the sensible load. The
MCHP provides thermal energy to regenerate the desiccant wheel by means of a thermal storage
tank; a peak-load boiler, fuelled with natural gas, provides thermal energy integration. Electricity
from the cogenerator is used to drive the electric chiller, the auxiliaries of the AHU and of the MCHP
itself (fans and pumps), as well as additional electric appliances of the lecture room (lights,
computers, etc.), as shown in Fig. 10.
During the winter season, the MCHP and the boiler provide thermal energy for space heating
purposes. Electricity is supplied to auxiliaries and electrical appliances. During the intermediate
season, the AHU is inactive and cogenerated electricity is supplied to the electrical appliances of the
![Page 34: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/34.jpg)
34
lecture room. Furthermore, throughout the year, the system provides thermal energy for domestic
hot water (DHW) preparation to a nearby user (a gym).
This trigeneration system is compared with a reference system (conventional system, CS), equipped
with a conventional air handling unit, based on cooling dehumidification for summer operation.
Electricity is drawn from the grid to power an electric chiller, the auxiliaries of the AHU, as well as
electrical appliances. Thermal energy for winter space heating, air post-heating during summer, and
DHW purposes is provided by a natural-gas boiler.
Experimental data acquired in a test facility of “UniversitàdegliStudi del Sannio” in Benevento
(Southern Italy), as well as data provided by manufacturer were used to calibrate and validate
models of the main components and energy-conversion devices. These models were used to
simulate the current MCCHP system by means of the TRNSYS software in order to evaluate
operational data and performance parameters.
2.6.2 Performance assessment procedure
The following analyses were applied within this Subtask B study: energy analysis, CO2 emission
analysis, economic analysis ([1], section IV.1):
The energy, environmental, and economic analysis involved the following steps: A building simulation
produced values for energy demand and, by simulation of the building integrated generation
systems, the demand for delivered energy to the building. Primary energy consumption was also
derived by simulation of generation systems. From these energy values, further figures such as
overall efficiencies, primary energy ratio, emissions, and operating costs were derived. Post-
processing was performed to calculate comparative indicators (FESR, ΔCO2,eq, SPB, etc.).
The following systems are used as the reference energy system:
• condensing gas boiler, providing heat for space heating and for loading a DHW storage tank;
• electric compression chiller, providing cold for space cooling;
• electricity supply from the electric grid.
In terms of economic performance, the effect of three policy instruments on the feasibility of the
system is analysed: a subsidy on gas price, a CHP generation bonus, and an investment subsidy.
![Page 35: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/35.jpg)
35
Fig. 11: The test facility.
![Page 36: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/36.jpg)
36
2.6.2 Building, loads, and external factors
The system is installed in Benevento (mean annual temperature 13.8 °C), for which the
corresponding “Meteonorm” climatic file was used. Benevento belongs to climatic zone C for Italy,
with 1,316 heating degree days and a heating period from November 15th to March 31th (for a
maximum of 10 hours/day). The length of the cooling period was assumed from June 1st to
September 15th. Finally, the intermediate season is from September 16th to November 14th and
from April 1st to May 31th.
The small-scale trigeneration system, based on the desiccant-based cooling system, provides the air-
conditioning service to a lecture room (63.5 m2 floor area, activation schedule from Monday to
Saturday from 9:00 to 19:00) during summer and winter periods. The summer and winter set-point
temperatures are 26 °C and 20 °C, respectively.
The occupancy schedule, the rates of heat gain from occupants, the heat gain from artificial lighting,
the dimensions and thermal insulation characteristics of the opaque and transparent components of
the building envelope, as well as the infiltration rate were set using the interface "TRNBuild" of
“TRNSYS” and its "type 56" to simulate the cooling and heating loads. A typical value of electric
energy consumption in office applications was assumed.
The classroom has no DHW demands; therefore, it is assumed that such DHW is provided to a nearby
building (i.e. a gym) as explained in next section. A tool to generate realistic domestic hot water load
profiles was developed in the framework of “IEA/SHC Task 26.” Throughout the year, the MCHP
provides thermal energy, by means of the storage tank, for DHW preparation with a requirement of
1,200 litres per day.
2.6.3 Description and characteristics of main system components
MCHP
A simplified MCHP model, suited for whole-building simulation software, has been developed,
calibrated, and validated by means of the available experimental data on a AISIN Toyota MCHP.
To simulate the micro-cogenerator operation, the “TRNSYS” RIC (reciprocating internal combustion)
engine model has been used: “type 907.” It uses a table of performance data to determine the
outputs of the engine, given a set of input conditions. The model relies on an external data file which
contains efficiency (both mechanical and electrical), air flow rate (fraction of rated flow rate), and
heat transfer data (fraction of total thermal power recovered from the generator, the oil cooler, the
exhaust gas heat exchanger, the engine jacket, and the fraction dissipated to the environment) as a
function of the intake temperature and the part-load ratio (actual power over rated power).
A plate heat exchanger, used to transfer the recovered thermal power to a secondary fluid (i.e.
water), a three-way valve that mixes the part of solution flow rate that passes through the plate heat
exchanger and the one that is bypassed toward the engine, and the control system that manages the
thermal recovery circuit of the micro-cogenerator were also modelled.
![Page 37: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/37.jpg)
37
Thermal storage tank
In the test facility of University of Sannio, a thermal storage system was installed and experimentally
tested. It has three heat exchangers: two of them, placed in the lower and upper part of the storage,
are carbon steel heat exchangers that can interact with an external energy-conversion device; the
third one, that extends along the entire height of the storage, is a stainless steel corrugated coil heat
exchanger for domestic hot water “production.” A third energy-conversion device can directly
interact in open circuit with the fluid stored in the tank.
The model used to simulate the described storage tank is "type 60," which represents the most
detailed model available in TRNSYS to simulate stratified thermal storage. The thermal performance
of a water-filled sensible energy storage tank, subject to thermal stratification, is modelled by
assuming that the tank consists of N fully-mixed equal-volume segments; for each of them a uniform
temperature is considered. The degree of stratification is determined by the value of N. If N=1, the
storage tank is modelled as a fully-mixed tank and no stratification effects are possible. By means of
experimental tests conducted in the test facility of University of Sannio, the model was
experimentally calibrated and validated.
The desiccant wheel
The desiccant wheel is a rotor filled with desiccant material and used to dehumidify the process air,
exploiting the difference in water vapour pressure between the incoming humid air and the surface
of the desiccant material. In order to ensure a continuous operation of the system, the DW has to be
regenerated by means of a regeneration air flow, heated up to a suitable temperature (from 60 °C up
to 140 °C, depending on the adsorbent material and the desired humidity ratio reduction).
The simplified approach of Maclaine-Cross and Banks has been used to model the DW [11]. This
approach models the dehumidification process, a combined heat- and mass-transfer process, in
analogy with a simple heat-transfer process. Equations for coupled heat and mass transfer are
reduced to two uncoupled differential equations of two independent variables (characteristic
potentials). Then, actual outlet conditions are estimated using two effectiveness indices of the wheel,
calculated in analogy to the efficiency of a heat exchanger. Intense laboratory activities provided
over 200 hours of experimental data necessary to calibrate and validate the model.
2.6.4 Results
The performance of the AS and CS strongly depend on several operating conditions. First is the
electric demand profile that influences the share of self-use of electricity. The best case is achieved
when the maximum value of the share of self-use electricity is assumed; for the analysed case, the
maximum value of this ratio means that no electricity is drawn from the grid for electric appliances
and auxiliaries, and about 10% of the cogenerated electricity is exported to the grid.
The analysed system is favourable with respect to the conventional one in terms of energy and
environmental performance, achieving a primary energy saving of about 7% and a CO2 emissions
saving of about 15%. However, to guarantee the economic feasibility of the system, it is necessary
that it can access the support mechanisms introduced by Italian legislation for small-scale gas-fuelled
![Page 38: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/38.jpg)
38
trigeneration systems: a lower taxation on gas price, the white certificates, an investment subsidy
(up to 40% of the investment cost), and the net metering scheme. In fact, if the analysed system can
contemporary benefit from all these mechanisms, a quite acceptable simple payback period of about
9 years can be obtained.
2.6.5 Conclusions
From this performance assessment study, the following “rules of thumb” related to a micro-
trigeneration system with a desiccant-based air handling unit can be derived:
the performances of desiccant cooling systems are strongly influenced by outdoor thermal-
hygrometric conditions;
desiccant cooling is a very interesting technology, in particular for high latent load
applications;
in Mediterranean climates, the desiccant dehumidification technology can guarantee a
reduction of both energy consumption and GHG emissions;
in regions characterised by quite low thermal energy needs for space heating of buildings, it
is crucial to utilise thermal energy available from the MCHP also for DHW requirements and
to supply thermally-activated cooling systems, in order to increase the operating hours of the
system;
a key parameter is the size of the storage interacting with the MCHP unit, as a correct
dimensioning of the tank, as well as an optimal control of the cogenerator/storage system,
can reduce the number of starts and stops of the device, increasing its durability;
the investment costs for this system are still quite high; therefore, it is necessary that it can
access all the support mechanisms introduced by Italian legislation for small-scale gas-fuelled
trigeneration systems.
2.7 Canada
In [12], a study is described to analyse the hybridisation of Stirling engine-based residential
cogeneration systems with solar thermal systems in order to meet the space- and water-heating
loads of a typical Canadian family house. Simulation results of four hybrid system configurations
applied in various locations in Canada are presented and compared to a base case system without
solar input. Additional optimisation cases are discussed.
Adding solar collectors to a residential cogeneration system has a clear potential to reduce natural
gas consumption and GHG emissions. The simulated cases showed a 10–15% decrease in the
consumption of natural gas, which corresponds to a GHG emission reduction of approximately 700–
1200 kg per house per year (depending on configuration and location).
Hybrid systems are complex and highly integrated systems. A full system optimisation was therefore
not possible in this study. Recommendations are given for further optimisation of these type of
systems.
![Page 39: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/39.jpg)
39
2.7.1 Method
The hybrid systems were simulated in the whole-building simulation program TRNSYS and annual
simulations were run for various locations in Canada using standard Canadian weather for energy
calculation (CWEC) data. Performance of the hybrid systems was compared to that of a reference
system without renewable energy input. The aim was to maximise the usage of solar energy by
varying system configuration, collector area, heat storage capacity, and hybrid system control
strategy. The modelling approach was to use measured data from non-optimised prototypes or early-
generation systems, including real-life efficiency losses (internal power consumption, reduced
performance from cyclic operation, etc.).
2.7.2 System description
Base case
A Stirling engine (SE)-based micro-cogeneration system is the heart of the base case system. The SE
provides heat to a 284-litre DHW storage tank through an immersed heat exchanger. A second heat
exchanger in the tank allows heat to be extracted for space heating through a hot water-fed air
handler. The storage tank is equipped with a back-up boiler to provide additional heat in case the SE
is not able to keep the DHW water at the desired temperature level.
Hybrid renewable – microgeneration energy systems
Solar heat is used in four variants of a hybrid renewable–microgeneration energy system to replace
fossil energy for space heating and DHW production. In Cases 1 and 2, solar heat is only used to heat
DHW; in Cases 3 and 4 the output of the solar collectors is used for both DHW and space heating.
Cases 2 and 4 (Fig. 12) differ from Cases 1 and 3 in that they have a preheat tank interacting with the
solar circuit, aimed at enhancing the solar yield.
Microcogeneration system
The model is based on the Annex 42 combustion cogeneration model, [7],[8]. The parameters of the
model are based on a calibration resulting from experimental testing of a modern Stirling engine. The
model takes differences in cooling water temperatures into account when calculating thermal and
electrical efficiencies. The SE is operated in on/off mode and produces approximately 7 kW of heat.
Solar collectors
TRNSYS “type 539” was used to model the thermal performance of flat-plate solar collectors. In this
component model, the collector efficiency curve is modelled by a first-order equation, and correction
for off-normal solar incidence is applied by a second-order incidence angle modifier (IAM).
![Page 40: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/40.jpg)
40
Fig. 12: Configuration for Case 4.
The solar collector model was calibrated on the basis of manufacturer specifications. The solar
collectors were assumed to be installed at the optimum angle for the investigated locations.
Furnaces and boilers
The furnaces and gas-fired boilers were modelled as on/off devices with a capacity of 29.3 kW, with
efficiencies of 92% and 85%, respectively, based on HHV.
Heat storages
Heat storage tanks were modelled as vertical storage tanks with immersed coiled tube heat
exchangers and with flow streams passing in and out (TRNSYS “type 534”). Each storage tank was
divided into ten isothermal temperature nodes in order to model stratification in the tank. Heat
losses to the environment were also considered in the model.
Balance of Plant
A commercially available air handler was used to calibrate the air handler model in “TRNSYS” (“type
753a”). Power consumed and flow rates for the pumps were also set for the simulations.
Control strategies
Two separate temperature nodes in the DHW tank are used to control when the SE and auxiliary
back-up heaters are turned on and off. The solar pump turns on when the difference between the
panel outlet temperature and the bottom of the preheat tank (or the DHW tank when only one tank
is used) is greater than 10ºC; it turns off when this difference is less than 3ºC. The tank recirculation
pump turns on when the difference between the top of the preheat tank and the bottom of the DHW
tank is greater than 7ºC; it turns off when this difference is less than 2ºC. The house thermostat
controls the circulation fan, the air handler, and, if needed, the furnace to 21ºC ± 0.5ºC. When the SE
serves the DHW and air handler coil in parallel, the SE comes on when there is either a demand for
space heating or to heat the DHW storage. Priority is given to heating DHW.
![Page 41: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/41.jpg)
41
House model
The house model is based upon the twin research houses of the Canadian Centre for Housing
Technology in Ottawa. The model was first calibrated against the measured space-heating demand of
one of the houses. Subsequently, the insulation thickness and air tightness in the model were
decreased to the level at which the model would represent a house situated in Ottawa with a heat
load equal to the space heating demand of the average Canadian single detached house. A daily
schedule was applied of 6 DHW draws, totalling 200 litres of hot water per day.
2.7.3 Basis for results comparison
The performance index for comparing hybrid systems to the reference system is the potential to
reduce natural gas consumption and associated GHG emissions. The net electricity consumed is
considered as being supplied by a 51% (HHV) efficient natural gas-fired combined-cycle power plant.
An 8% loss for transmission and distribution of grid electricity was taken into account.
Natural gas for heating and power production was assumed to have an emission intensity of 59.4 kg
GHGeq/GJ.
2.7.4 Results
Main results for the simulated cases are presented in Tab. 6 and Fig. 13.
The base case system has been simulated for four cities in Canada: Vancouver, Calgary, Ottawa, and
Halifax. These cities represent different geographical areas and climates, which results in a range of
space-heating loads. The operational characteristics of the base case system are very similar for all
locations. The SE supplies close to 90% of the total heat demand for SH and DHW, with the back-up
heater providing the remainder.
Cases 1 and 2 use solar heat for DHW production. A series configuration of two solar collector panels
with a total surface area of 5.748 m2 produce 7% and 10% of the total annual heat demand for
Ottawa Cases 1 and 2, respectively. The solar heat primarily replaces the output of the back-up
heater. The reductions in natural gas consumption and GHG emissions compared with the base case
were 9.9% for Case 1 and 12.2% for Case 2.
Solar heat is used in Cases 3 and 4 for both space heating and DHW. The systems are equipped with
four solar collector panels in series (11.496 m2 total area). The solar heat replaces output from both
the SE and the back-up heater. The reduction in natural gas consumption and GHG emissions is
11.2% for Case 3 and 10.4% for Case 4, for location in Ottawa. For both Cases 2 and 3, the operation
and performance of the hybrid systems are very similar over the range of heating conditions for the
analysed cities.
Parameter variation cases were run in order to investigate the effect of doubling the solar collector
area, doubling the volume of the heat storage tanks, and removing the low-flow pump between the
two heat storages. Doubling the area of the solar panels results in a 49% increase in solar yield for
Case 2 and 28% more solar heat collected for Case 3, but with a marginal improvement, as the
![Page 42: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/42.jpg)
42
additional solar heat captured mainly replaces thermal output from the SE. The reduction in natural
gas consumption and in GHG emission increases to 14.0% for Case 2 and 14.1% for Case 3.
Tab. 6: Main results for all simulated cases
SE
he
at
ou
tpu
t
Ba
ck-u
p b
urn
er
Fu
rna
ce
So
lar
he
at
ou
tpu
t
SH
lo
ad
*
DH
W lo
ad
Ta
nk h
ea
t lo
ss
SE
ne
t p
ow
er
ou
t
Fa
n p
ow
er
Oth
er
HV
AC
ele
c
‡
SE
ne
t η
th (
cycle
) †
SE
ne
t η
el (
cycle
) †
Avg
SE
cycle
tim
e
So
lar
η
% % min % %
Base
Vancouver 17.5 2.4 0.0 0.0 15.2 5.0 0.5 1.2 0.8 0.1 70.4 4.9 104 N/A
Halifax 22.3 2.7 0.0 0.0 20.5 5.0 0.5 1.7 1.0 0.2 70.5 5.4 126 N/A
Ottawa 25.2 3.1 0.0 0.0 24.0 4.9 0.5 2.1 1.1 0.2 70.5 5.8 168 N/A
Calgary 25.7 3.5 0.0 0.0 25.0 4.8 0.5 2.1 1.1 0.3 70.5 5.9 169 N/A
Case 1
Ottawa 25.2 0.0 1.4 2.0 24.6 5.0 0.4 1.9 1.2 0.1 74.8 5.7 123 22.2 9.9
Case 2
Vancouver 17.4 0.0 0.0 2.7 15.5 5.1 0.7 1.0 1.0 0.1 74.7 4.2 78 33.0 12.8
Halifax 22.6 0.0 0.1 2.6 20.9 5.1 0.7 1.6 1.2 0.1 74.8 5.2 101 31.0 11.4
Ottawa 25.0 0.0 0.7 2.8 24.4 5.0 0.7 1.9 1.3 0.1 74.8 5.8 141 31.2 12.2
Calgary 25.5 0.0 1.2 3.2 25.5 5.2 0.7 2.0 1.3 0.1 74.8 5.8 136 30.8 11.8
Case 3
Vancouver 15.7 0.8 0.0 3.9 15.4 5.3 0.6 1.0 0.8 0.2 70.3 4.6 97 24.2 13.6
Halifax 20.8 0.8 0.0 3.8 20.8 5.1 0.6 1.6 1.0 0.3 70.4 5.3 122 22.8 11.0
Ottawa 23.4 1.0 0.0 4.2 24.2 5.0 0.6 1.9 1.1 0.4 70.5 5.8 171 23.2 11.2
Calgary 23.9 1.1 0.0 4.7 25.2 5.1 0.6 2.0 1.2 0.4 70.5 5.8 171 22.7 11.8
Case 4
Ottawa 23.6 1.1 0.0 4.3 24.2 5.2 0.7 1.9 1.1 0.4 70.5 5.8 172 23.7 10.4
2xVol tank (Ottawa)
Base 27.0 1.5 0.0 0.0 24.0 4.9 0.7 2.4 1.1 0.2 70.5 6.8 321 N/A 0.0
Case 2 25.0 0.0 0.6 3.0 24.4 4.7 1.0 1.9 1.3 0.1 74.8 5.8 144 33.2 12.6
Case 3 23.9 0.4 0.0 4.5 24.2 4.9 0.9 2.0 1.1 0.3 70.4 6.0 282 24.6 12.0
2xA panel (Ottawa)
Case 2 24.6 0.0 0.6 4.2 24.4 5.7 0.8 1.9 1.3 0.1 74.8 5.8 131 23.2 14.0
Case 3 22.7 0.9 0.0 5.4 24.2 5.3 0.6 1.8 1.1 0.3 70.5 5.7 176 14.9 14.1
Case 2 25.1 0.0 0.7 2.8 24.4 5.0 0.7 1.9 1.3 0.1 74.7 5.8 140 30.5 12.1
Optimized cases (Ottawa)
Case 3-50° 23.3 1.0 0.0 4.2 24.2 5.0 0.6 1.9 1.1 0.4 70.5 5.8 128 23.5 11.5
Case 1-Opt. 24.7 0.0 0.6 3.7 24.4 5.5 0.6 1.9 1.3 0.1 74.8 5.8 85 20.3 13.7
Case 3-LTH 19.8 4.2 0.0 4.5 24.5 4.8 0.5 1.5 1.2 0.4 73.6 5.5 128 25.0 15.0
Heat out of system Electricity
Low-flow pump off (Ottawa)
(Ba
se
)
Performance
NG
sa
vin
gs a
nd
GH
G r
ed
uctio
n ₤
MWh MWh MWh
Con
fig
ura
tio
n
Heat into system
* Space heating load consists of heat output of air handler and furnace and the electrical load of the fan.
‡ This is the power consumed by the air handler pump, the solar pump, and the low-flow pump.
† Presented SE efficiencies are cycle efficiencies, which are lower than full load efficiencies due to losses from warm-up,
cool-down, and stand-by periods.
The base case with double tank volume has a 14% higher SE power production thanks to increased
use of the SE and a higher electrical efficiency due to a near doubling of the average cycle time. This
improvement, however, is totally consumed by a higher demand for natural gas to overcome higher
![Page 43: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/43.jpg)
43
heat losses from the storage tank and efficiency differences between the SE and the back-up heater.
Overall, the base case with a double tank size has the same natural gas use and GHG emissions as the
original base case.
Case 2 with double heat storage volumes shows a small increase in solar yield. The operation of the
hybrid system is almost identical to that of the regular Case 2 and natural gas consumption and
emissions decrease by 0.4%. As regards Case 3, owing to a 6% higher solar input, a net reduction in
natural gas consumption and GHG emissions of 0.8% is achieved in comparison with the standard
Case 3 for Ottawa. Turning off the low-flow-pump in Case 2 has a net effect of –0.1% in natural gas
saving and GHG emission reduction.
0
2
4
6
8
10
12
14
16
Cas
e 1
Cas
e 1-
Opt
Cas
e 2
Cas
e 2
- 2xV
olta
nk
Cas
e 2
- 2xA
pane
l
Cas
e 2
- Low
-flow
pum
p of
f
Cas
e 3
Cas
e 3
- 2xV
olta
nk
Cas
e 3
- 2xA
pane
l
Cas
e 3-
50°
Cas
e 3-
LTH
Cas
e 4
NG
Savn
igs a
nd
Em
issio
n R
ed
ucti
on
Co
mp
are
d t
o B
ase C
ase (
%)
Vancouver Halifax Ottawa Calgary
Fig. 13: NG savings and GHG emission reduction for simulated cases compared
to the base case for the same location.
In all cases described above, the solar collector panels were assumed to be installed at the optimum
angle for total annual solar heat production (37°). A number of simulations were run for Case 3
(Ottawa) with a variation of solar panel angle. A slightly higher angle (50°) than the 37° used in the
first round of simulations is favourable towards optimum overall efficiency. With the solar panel at
the optimum angle of 50°, two routes for further optimisation were investigated. The first route
aimed at maximising the use and performance of the Stirling engine, while also trying to capture the
greatest amount of solar heat. Because of its similarities to Case 1, this case was called ‘Case
1_Optimized’. The results show an almost exclusive use of the Stirling engine in providing heat for
space heating and DHW. With a 13.7% reduction in natural gas use and associated emissions, this
configuration has a better performance than both the original Case 1 and Case 3 with a solar panel
angle of 50°.
![Page 44: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/44.jpg)
44
The second route for optimisation was the application of the hybrid system with a low-temperature
heating (LTH) system, i.e. a floor heating system. Using a Case 3-type configuration, the results for
Case 3_LTH clearly show the positive effect of lower heat storage temperatures on the performances
of the Stirling engine and the solar panels. The thermal efficiency of the Stirling engine increased to
73.6% compared to 70.5% for Case 3 with solar panels at an angle of 50°. The heat production by the
solar panels increased by 6% from 4.2 to 4.5 MWh. Case 3_LTH has the highest percentage of
reduction in natural gas use and associated GHG emissions of all evaluated cases: 15.0%.
2.7.5 Conclusions
In this report, a study is presented into the hybridisation of residential cogeneration systems and
solar thermal technology for providing space heating and domestic hot water to a residence with an
average heating load. Hybrid systems displaying various configurations and parameter settings were
simulated in TRNSYS and their results compared to a base case without solar input. From this study,
it can be concluded that:
• adding solar collectors to a residential cogeneration system has a clear potential to reduce
natural gas consumptions and GHG emissions. Simulated cases showed a reduction in annual
natural gas consumption of 10–15%, which corresponds to a reduction of approximately
700–1200 kg GHG per house per year;
• providing low heat-exchange temperatures for both the Stirling engine and the solar thermal
system is crucial for high system efficiencies;
• it is important to provide sufficient storage capacity for the collected solar heat;
• system performance increases with solar collector area, but with a rapid decrease in
marginal improvement;
• the solar-panel angle has a limited impact on the overall system performance;
• the hybrid systems show similar operation and performance when applied in four cities
across Canada with a broad range of heat demands.
![Page 45: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/45.jpg)
45
3 Review of Other Country-specific Results Deriving from
the Microgen III Conference
3.1 Germany
To calculate the potential of small-scale cogeneration in Germany, technical data of MCHP systems
and performance data from field tests and laboratory experiments have been taken into account in
[13]. The business areas were selected according to a significant yearly heat demand: a butcher shop,
a small hotel, and a fitness centre. To derive the economic potential, cost data of the systems and
tariffs for electricity and natural gas have been included, as well as the current regulatory framework.
The investment for the MCHP system has to be recovered by cost reductions during the life time
compared to a conventional heating system and electricity purchase from the grid. Fig. 14 shows a
sensitivity analysis of such a system. In addition, the base values for the different parameters are
included into the legend. The parameters are varied from 20% below to 20% above the base value
and the impact on the annual total profit is shown. A MCHP system with a maximum electrical output
of 50 kW and thermal output of 120 kW that achieves 5,000 full load operating hours annually is
considered for the analysis.
Fig. 14: Influencing factors on annual total profit of MCHP.
The profit is very sensitive on the utilisation time, the electricity purchase costs, and the investment
costs. With progressing market entry, lower investment costs and better profitability can be
expected. The crucial parameter is the utilisation time; a decrease of only 5% would lead to an
economic deficit of the CHP system.
![Page 46: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/46.jpg)
46
The potential of MCHP in the small business sector in Germany has been projected from statistical
data. The higher heat demand during the summer is an advantage of non-residential applications and
increases the profitability of MCHP systems. However, the potential for MCHP systems in the sectors
trade, commerce, and services is limited. Also, by including CHP systems with higher capacity, a total
of about 40% of the heat and about 25% of the electricity demand of the sector TCS could be
supplied.
In [14], the need to develop typical profiles of heat load, DHW tapping, and electricity demand for
real-time experiments of CHP (combined heat and power) systems is analysed. These load profiles
are needed for three typical days, representing the climatic periods summer, winter, and transition
time.
For the selection of these so called “Type Days,” a method is implemented. First, each day of a field
measurement campaign is classified as Summer, Winter, or Transition Day, depending on its mean
ambient temperature. Second, for each group, mean profiles of heat load, DHW tapping, and
electricity demand are calculated. Subsequently, Type Days are selected using a least-squares
approach. Depending on these Type Days, load profiles with a resolution of one minute are
calculated and used as input data for the test bed at the Institute for Energy Economy and
Application Technology (IfE), where it is possible to apply different hydraulic schemes with dynamic
heat loads and DHW tapping profiles for MCHP testing. Results show very good consistency of test-
bed data with the data measured during the field test in terms of electricity generation, heat supply,
and system efficiency of the MCHP.
The results confirm that using MCHP units in the sector of trade and services can be ecological and
economical, especially in business sectors with a high heating base load. In particular, an optimised
hydraulic system gives (Fig.15) a potential of up to 6% of primary energy saving.
Fig.15: Optimized hydraulic system.
![Page 47: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/47.jpg)
47
3.2 United Kingdom
In the UK, heat pumps are often promoted as the means to provide low-carbon space heating and
hot water for future dwellings as the electricity supply decarbonises. However, a major issue with
growing heat-pump use is the additional load that this could place on the electrical network. A means
to alleviate potential demand problems is to stagger the operating times of heat pumps by
integrating them with thermal buffering. However, focusing on the domestic sector, substantial
volumes of thermal storage would be required, and this poses a particular problem in the UK where
the floor areas of urban dwellings are small. Thermal storage featuring phase change material (PCM)
offers the potential of more volumetrically efficient heat buffering, which may be more suitable for
integration into domestic heating systems.
In [15], the potential to shift the operating time of heat pumps integrated with PCM-enhanced
thermal storage is assessed and compared to conventional hot-water storage, where the limits of
flexible operation are determined by the comfort and hot water needs of the end-user. In particular,
an integrated “ESP-r” model of a conventional UK detached dwelling (usable floor area of 136 m2
spread over an upper and ground floor), featuring an 11-kW nominal thermal output air source heat
pump (ASHP) heating system (Fig. 16), was used to investigate the potential for PCM thermal storage
and to provide practical and more efficient thermal buffering for the load shifting of heat pumps.
Fig. 16: The modelled heating system supplied by the ASHP with PCM-enhanced buffer tank.
The operating times of the heat pump were set to off-peak periods (when the house was unoccupied
or when the occupants were asleep), whilst the volume of the thermal buffer was varied from 200–
1200 L and the percentage of PCM in the thermal buffer (by volume) was varied from 0% up to 70%.
The performance of both the buffered system (with and without PCM) was compared to the case
with no load shifting, where the heat pump was connected directly to the heating circuit and the
DHW tank (reference case). In the unbuffered case, the hours of heating operation were set to the
periods of active occupancy within the dwelling.
![Page 48: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/48.jpg)
48
The simulations were undertaken for winter, spring, and summer weeks for a warm (Southern
England) and cool (North East Scotland) climate. In total, 186 simulations were undertaken, with a 1-
min time resolution. For each simulation, the heat pump performance data was post-processed to
determine the energy costs for the end user and the carbon emissions associated with the use of the
heat pump.
The results indicate that in all cases the PCM-enhanced buffer offers improvements in terms of the
size of storage required to achieve effective load shifting: the size of the buffer tank could be
reduced by between 2–3 times compared to hot-water buffering. For example, without PCM, a tank
size of 1200 l was required to load shift over the winter weeks for both the warm and cold climates—
this would be a very large tank to accommodate within a dwelling. With PCM added, a 500 l tank is
required for the winter week for both the UK climate sets.
However, thermal buffering with load shifting can increase heat pump energy demand and (at
present) in the UK results in increased emissions and cost penalties for the end user. These results
may change in future as the energy mix of the UK electricity system changes and if tariff structures
are revised to encourage load shifting.
For example, Fig. 17 shows that, for the case of the warm-climate winter week, increasing the buffer
size and the addition of PCM to the buffer tank increased the electrical energy consumption of the
heat pump. In the worst case, the PCM-enhanced buffer results in a 38% energy penalty compared to
the reference case.
Fig. 17: Electrical energy consumption of heat pump for operation shifted to off-peak
against % of PCM in buffer tank for different buffer tank volumes; warm UK climate, winter week.
The increased heat pump electrical energy use is attributable to two main causes. Firstly, the
addition of the buffering tank introduces extra standing system losses. Second, the COP of the heat
pump is reduced by up to 15% because of the addition of a heat exchanger in the buffer (it is
![Page 49: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/49.jpg)
49
necessary to supply water to the buffer at a higher temperature) and because the heat pump
operates at off-peak times when ambient temperatures are lower.
Furthermore, the addition of sensible-only buffering is beneficial with respect to the cycling of the
heat pump. The large sensible store reduces heat pump cycling by up to 35%. This could have a
beneficial effect on both maintenance requirements and the heat pump lifespan. However, with the
PCM-enhanced thermal buffer, there is no clear reduction in thermal cycling.
![Page 50: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/50.jpg)
50
4 Conclusions
From the analysed performance assessment of country-specific studies, it can be concluded that
fossil fuel-based microgeneration systems can achieve primary energy and emissions savings in the
range 5–20%, depending on the type of system and applications. These savings increase up to 40%
when renewable energy technologies are involved in hybrid microgeneration systems. A maximum
value of 60% was found, in terms of primary energy and emissions savings, when more than one
renewable energy source is exploited (e.g., geothermal and solar energy).
In terms of economic performance, significant capital cost savings (about 20–30%) can be obtained,
but very often the initial installation cost is still considerably high, especially for very complex small-
scale trigeneration systems, determining quite long pay back periods, even assuming that all the
support mechanisms introduced by national legislations are effectively achieved. Therefore, specific
financing mechanisms should be promoted in order to overcome the problems related to high
investment costs such as, for instance, third-party financing and favoured access to national and
international government funding. Moreover, there is the need to further improve the performance
of microgeneration systems, to increase the cost savings with respect to conventional systems based
on separate “production;” a reduction of the installation costs performed by manufacturers and
distributors of high-efficiency energy conversion devices would be also highly desirable.
As a conclusion, it should be highlighted that the aforementioned energy, environmental, and cost
benefits can be achieved if the following main "rules of thumb" are observed, both in the design and
the operation phases of small-scale cogeneration and trigeneration plants:
• the energy-saving effects differ with household-type, therefore an optimal solution exists for
each household category;
• the best energy, environmental, and economic performance are obtained with thermal load-
following logic of the MCHP, rather than electric-load following logic;
• under thermal load-following logic, the best results are obtained in more colder climates;
• the benefits increase when the utilisation time of the microgeneration system increases, as it
represents the most crucial parameter;
• the performance of the system deeply depends on the ratio between thermal and electric
load;
• the correct sizing of the storage tank is a crucial issue, as it allows the minimisation of the
total primary energy consumption, the equivalent carbon dioxide emissions, and the
operating costs of the microgeneration system;
• the thermal recovery circuit should be properly designed, i.e. achieving enough low return
temperature to maximise the performance of combustion-based devices and solar thermal
systems;
• the performance of microgeneration systems strongly increases with the share of own-use
electricity;
• the electric demand profile including the overnight charging of the electric vehicle provides
better results of the MCHP, in comparison to the electric demand profile without the
![Page 51: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/51.jpg)
51
overnight charging of the electric vehicle, only when the MCHP unit is operated under
electric load-following logic;
• higher operational energy savings can be achieved with the load-sharing approach, with
optimal system sizing and appropriate control strategy implementations;
• an electrically driven cooling device based on vapour compression systems should be at the
moment preferred to a thermally activated one (absorption chiller or desiccant cooling
system) in small-scale trigeneration systems, as the former allows the achievement of higher
overall efficiency;
• the economic feasibility of microgeneration systems is very sensitive on the electricity
purchase costs and the investment costs;
• with progressing market entry of microgeneration technologies, lower investment costs and
better profitability can be expected.
![Page 52: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/52.jpg)
52
Terminology and Abbreviations
ABHP Absorption Heat Pump
AHU Air Handling Unit
AS Alternative System
ASHP Air Source Heat Pump
ASHRAE America Society of Heating Refrigeration and Air Conditioning Engineers
CHP Combined Heat and Power
CO2 Equivalent CO2 emissions
COP Coefficient Of Performance
CS Conventional System
DCS Desiccant Cooling System
DHW Domestic Hot Water
DW Desiccant Wheel
EHP Electric Heat Pump
EV Electric Vehicle
FESR Fuel Energy Saving Ratio
GHG Green House Gas
GSHP Ground Source Heat Pump
HCPV High Concentrator PhotoVoltaic
HHV Higher Heating Value
HVAC Heating, Ventilation and Air-Conditioning
IAM Incidence Angle Modifier
ICE Internal Combustion Engine
LHB condensing water heater
LTH Low Temperature Heating
MCCHP Micro Combined Cool Heat and Power
MCHP Micro Combined Heat and Power
MGE Micro Gas Engine
NE Net Energy
NG Natural Gas
NPV Net Present Value
OE Output Energy
PCM Phase Change Material
PE Primary Energy
PEFC Polymer Electrolyte Membrane Fuel Cell
PEMFC Proton Exchange Membrane Fuel Cell
PHEV Plug-in Hybrid Electric Vehicles
PV PhotoVoltaic
PV/T PhotoVoltaic-Thermal
RIC Reciprocating Internal Combustion
![Page 53: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/53.jpg)
53
SOFC Solid Oxide Fuel Cell
SE Stirling Engine
SH Space Heating
SPB Simple Pay Back period
TES Thermal Energy Storage
TRNSYS TRaNsientSYStems
Subscripts
Cool cooling
El electric
Fuel fuel primary energy
Th thermal
Superscripts
aux auxiliaries
chil chiller
DCS Desiccant Cooling System
DHW Domestic Hot Water
GB Gas Boiler
HC Heating Coil
MCHP Micro Combined Heat and Power
ST Storage Tank
![Page 54: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/54.jpg)
54
References
[1] M. Sasso, G. Angrisani, C. Roselli, Methodologies for the performance assessment of micro
hybrid polygeneration systems, A Report of Subtask B of Integration of Micro-Generation and
Related Energy Technologies in Buildings, Annex 54 of the International Energy Agency, Energy
Conservation in Buildings and Community Systems Programme.
[2] N. Kelly, M. Sasso, G. Angrisani, C. Roselli, Impact of microgeneration systems on the low-voltage
electricity grid, A Report of Subtask B of Integration of Micro-Generation and Related Energy
Technologies in Buildings, Annex 54 of the International Energy Agency, Energy Conservation in
Buildings and Community Systems Programme.
[3] Y. Shimoda, T. Aoki, Performance assessment of residential cogeneration systems in Japan, A
Report of Subtask B of Integration of Micro-Generation and Related Energy Technologies in
Buildings, Annex 54 of the International Energy Agency, Energy Conservation in Buildings and
Community Systems Programme.
[4] H. Kuroki, S. Shimizu, M. Nakao, H. Aoki, H. Takaguchi, T. Watanabe, Study on energy
conservation effects of housing electricity and heat source equipments, Journal of
Environmental Engineering (Transactions of Architectural Institute of Japan, 5-26-20 Shiba,
Minato-ku, Tokyo 108-8414) 2010;647:43-50 [in Japanese].
[5] E.J. Lee, E.C. Kang, S. Cho, E. Entchev, L. Yang, M. Ghorab, Performance Assessment and Integral
Effect Test of Fuel Cell – Ground Source Heat Pump and Photovoltaic Thermal – Ground Source
Heat Pump, A Report of Subtask B of Integration of Micro-Generation and Related Energy
Technologies in Buildings, Annex 54 of the International Energy Agency, Energy Conservation in
Buildings and Community Systems Programme.
[6] Rosato, S. Sibilio, Performance Assessment of a Residential Building-Integrated Micro-
Cogeneration System in Italy, A Report of Subtask B of Integration of Micro-Generation and
Related Energy Technologies in Buildings, Annex 54 of the International Energy Agency, Energy
Conservation in Buildings and Community Systems Programme.
[7] N. Kelly, I. Beausoleil-Morrison, Specifications for modeling fuel cell and combustion-based
residential cogeneration devices within whole-building simulation programs, IEA/ECBCS Annex
42 report; 2007. ISBN No. 978-0-662- 47116-5.
[8] Ferguson, N. Kelly, A. Weber, B. Griffith, Modellingresidential-scale combustion-
basedcogeneration in building simulation, Journal of Building Performance Simulation
2009;2(1):1–14.
[9] Brandoni, M. Renzi, A. Mastrucci, F. Caresana, F. Polonara, Performance assessment of hybrid
micro-CCHP systems in central Italy, A Report of Subtask B of Integration of Micro-Generation
and Related Energy Technologies in Buildings, Annex 54 of the International Energy Agency,
Energy Conservation in Buildings and Community Systems Programme.
![Page 55: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/55.jpg)
55
[10] G. Angrisani, C. Roselli, M. Sasso, F. Tariello, Simulation of a micro-trigeneration system with a
desiccant-based air handling unit in Southern Italy climatic conditions, A Report of Subtask B of
Integration of Micro-Generation and Related Energy Technologies in Buildings, Annex 54 of the
International Energy Agency, Energy Conservation in Buildings and Community Systems
Programme.
[11] G. Angrisani, C. Roselli, M. Sasso, Experimental validation of constant efficiency models for the
subsystems of an unconventional desiccant-based Air Handling Unit and investigation of its
performance, Applied Thermal Engineering 33-34 (2012) 100-108.
[12] H. Ribberink, K. Lombardi, L. Yang, E. Entchev, Investigation of a Hybrid Renewable –
Microgeneration Energy System for Power and Thermal Generation with Reduced Emissions, A
Report of Subtask B of Integration of Micro-Generation and Related Energy Technologies in
Buildings, Annex 54 of the International Energy Agency, Energy Conservation in Buildings and
Community Systems Programme.
[13] P. Tzscheutschler, Potential of micro-CHP in small business sector in Germany, Proceedings of
Microgen III, the 3rd edition of the International Conference on Microgeneration and Related
Technologies (Naples, Italy, April 15-17, 2013), ISBN: 9788890848902.
[14] F. Sänger, J. Lipp, Computational selection of dynamic type days for test bed experiments based
on field measurements, Proceedings of Microgen III, the 3rd edition of the International
Conference on Microgeneration and Related Technologies (Naples, Italy, April 15-17, 2013),
ISBN: 9788890848902.
[15] N. J. Kelly, A. D. Hawkes, Load management of heat pumps using phase change heat storage,
Proceedings of Microgen III, the 3rd edition of the International Conference on Microgeneration
and Related Technologies (Naples, Italy, April 15-17, 2013), ISBN: 9788890848902.
![Page 56: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/56.jpg)
56
Background Information
International Energy Agency
The International Energy Agency (IEA) was established in 1974 within the framework of the
Organisation for Economic Co-operation and Development (OECD) in order to implement an
international energy programme. A basic aim of the IEA is to foster international co-operation among
the 28 IEA-participating countries, as well as to increase energy security through energy research,
development, and demonstration in the fields of technologies for energy efficiency and renewable
energy sources.
The IEA Energy in Buildings and Communities Programme
The IEA co-ordinates research and development in a number of areas related to energy. The mission
of the Energy in Buildings and Communities (EBC) Programme is to develop and facilitate the
integration of technologies and processes for energy efficiency and conservation into healthy, low
emission, and sustainable buildings and communities, achieving this through innovation and
research. (Until March 2013, the IEA-EBC Programme was known as the Energy in Buildings and
Community Systems Programme, ECBCS.)
The research and development strategies of the IEA-EBC Programme are derived from research
drivers, national programmes within IEA countries, and the IEA Future Buildings Forum Think Tank
Workshops. The research and development (R&D) strategies of IEA-EBC aim to exploit technological
opportunities to save energy in the buildings sector, and to remove technical obstacles to market
penetration of new energy-efficient technologies. The R&D strategies apply to residential,
commercial, office buildings, and community systems, and will impact the building industry in five
focus areas for R&D activities:
Integrated planning and building design
Building energy systems
Building envelope
Community scale methods
Real building energy use
The Executive Committee
Overall control of the IEA-EBC Programme is maintained by an Executive Committee, which not only
monitors existing projects but also identifies new strategic areas in which collaborative efforts may
be beneficial. As the programme is based on a contract with the IEA, the projects are legally
established as Annexes to the IEA-EBC Implementing Agreement. At the present time, the following
projects have been initiated by the IEA-EBC Executive Committee, with completed projects identified
by (*):
Annex 1: Load Energy Determination of Buildings (*)
![Page 57: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/57.jpg)
57
Annex 2: Ekistics and Advanced Community Energy Systems (*)
Annex 3: Energy Conservation in Residential Buildings (*)
Annex 4: Glasgow Commercial Building Monitoring (*)
Annex 5: Air Infiltration and Ventilation Centre
Annex 6: Energy Systems and Design of Communities (*)
Annex 7: Local Government Energy Planning (*)
Annex 8: Inhabitants Behaviour with Regard to Ventilation (*)
Annex 9: Minimum Ventilation Rates (*)
Annex 10: Building HVAC System Simulation (*)
Annex 11: Energy Auditing (*)
Annex 12: Windows and Fenestration (*)
Annex 13: Energy Management in Hospitals (*)
Annex 14: Condensation and Energy (*)
Annex 15: Energy Efficiency in Schools (*)
Annex 16: BEMS 1- User Interfaces and System Integration (*)
Annex 17: BEMS 2- Evaluation and Emulation Techniques (*)
Annex 18: Demand Controlled Ventilation Systems (*)
Annex 19: Low Slope Roof Systems (*)
Annex 20: Air Flow Patterns within Buildings (*)
Annex 21: Thermal Modelling (*)
Annex 22: Energy Efficient Communities (*)
Annex 23: Multi Zone Air Flow Modelling (COMIS) (*)
Annex 24: Heat, Air and Moisture Transfer in Envelopes (*)
Annex 25: Real time HVAC Simulation (*)
Annex 26: Energy Efficient Ventilation of Large Enclosures (*)
Annex 27: Evaluation and Demonstration of Domestic Ventilation Systems (*)
Annex 28: Low Energy Cooling Systems (*)
Annex 29: Daylight in Buildings (*)
Annex 30: Bringing Simulation to Application (*)
Annex 31: Energy-Related Environmental Impact of Buildings (*)
Annex 32: Integral Building Envelope Performance Assessment (*)
Annex 33: Advanced Local Energy Planning (*)
Annex 34: Computer-Aided Evaluation of HVAC System Performance (*)
Annex 35: Design of Energy Efficient Hybrid Ventilation (HYBVENT) (*)
Annex 36: Retrofitting of Educational Buildings (*)
Annex 37: Low Exergy Systems for Heating and Cooling of Buildings (LowEx) (*)
Annex 38: Solar Sustainable Housing (*)
Annex 39: High Performance Insulation Systems (*)
Annex 40: Building Commissioning to Improve Energy Performance (*)
Annex 41: Whole Building Heat, Air and Moisture Response (MOIST-ENG) (*)
Annex 42: The Simulation of Building-Integrated Fuel Cell and Other Cogeneration Systems
(FC+COGEN-SIM) (*)
Annex 43: Testing and Validation of Building Energy Simulation Tools (*)
![Page 58: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/58.jpg)
58
Annex 44: Integrating Environmentally Responsive Elements in Buildings (*)
Annex 45: Energy Efficient Electric Lighting for Buildings (*)
Annex 46: Holistic Assessment Tool-kit on Energy Efficient Retrofit Measures for Government
Buildings (EnERGo) (*)
Annex 47: Cost-Effective Commissioning for Existing and Low Energy Buildings (*)
Annex 48: Heat Pumping and Reversible Air Conditioning (*)
Annex 49: Low Exergy Systems for High Performance Buildings and Communities (*)
Annex 50: Prefabricated Systems for Low Energy Renovation of Residential Buildings (*)
Annex 51: Energy Efficient Communities (*)
Annex 52: Towards Net Zero Energy Solar Buildings (*)
Annex 53: Total Energy Use in Buildings: Analysis & Evaluation Methods (*)
Annex 54: Integration of Micro-Generation & Related Energy Technologies in Buildings
Annex 55: Reliability of Energy Efficient Building Retrofitting - Probability Assessment of
Performance & Cost (RAP-RETRO)
Annex 56: Cost Effective Energy & CO2 Emissions Optimisation in Building Renovation
Annex 57: Evaluation of Embodied Energy & CO2 Emissions for Building Construction
Annex 58: Reliable Building Energy Performance Characterisation Based on Full Scale Dynamic
Measurements
Annex 59: High Temperature Cooling & Low Temperature Heating in Buildings
Annex 60: New Generation Computational Tools for Building & Community Energy Systems Based
on the Modelica & Functional Mockup Unit Standards
Annex 61: Development & Demonstration of Financial & Technical Concepts for Deep Energy
Retrofits of Government / Public Buildings & Building Clusters
Annex 62: Ventilative Cooling
Annex 63: Implementation of Energy Strategies in Communities
Annex 64: LowEx Communities - Optimised Performance of Energy Supply Systems with Exergy
Principles
Annex 65: Long-Term Performance of Super-Insulation in Building Components and Systems
Annex 66: Definition and Simulation of Occupant Behaviour in Buildings
Working Group - Energy Efficiency in Educational Buildings (*)
Working Group - Indicators of Energy Efficiency in Cold Climate Buildings (*)
Working Group - Annex 36 Extension: The Energy Concept Adviser (*)
(*) – Completed
Annex 54
The Annex 54 “Integration of Micro-Generation and Related Energy Technologies in Buildings”
undertook an in depth analysis of micro-generation and other associated energy technologies.
![Page 59: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/59.jpg)
59
Scope of activities
• multi-source micro-cogeneration systems, polygeneration systems (i.e. integrated heating /
cooling / power generation systems) and renewable hybrid systems;
• the integration of micro-generation, energy storage, and demand-side management
technologies at a local level (integrated systems);
• customised and optimum control strategies for integrated systems;
• the analysis of integrated and hybrid systems performance when serving single and multiple
residences along with small commercial premises; and
• the analysis of the wider impact of micro-generation on the power-distribution system. To
broaden the impact of the Annex’s output there will be significant effort to disseminate its
deliverables to non-technical stakeholders working in related areas such as housing, product
commercialisation, and regulatory development.
Outcomes
• An update on occupant-related DHW and electric load profiles.
• Component models and their implementation in building simulation tools.
• Review of best practices in the operation and control of integrated micro-generation
systems.
• Predictive control algorithms to maximise the performance and value of micro-generation.
• Experimental data sets for the calibration and validation of device models.
• Performance assessment methodologies.
• Country-specific studies on the performance of a range of micro-generation systems.
• Studies of the viability of micro-generation systems in different operational contexts and of
the impacts of micro-generation on the wider community and the potential benefits, in
particular for the electricity network.
• An investigation of interactions between technical performance and commercialisation/
regulatory approaches for micro-generation.
• Compilation of case studies of the introduction of microgeneration technologies.
Annex 54 was built upon the results of Annex 42 "The Simulation of Building-Integrated Fuel Cell and
Other Cogeneration Systems."
To accomplish its objectives, Annex 54 conducted research and development in the framework of the
following three Subtasks:
Subtask A - Technical Development
This subtask contains a broad range of activities related to models and load profiles development,
data collection, and micro-generation systems for predictive controls development and optimisation.
![Page 60: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/60.jpg)
60
Subtask B - Performance Assessment
This subtask uses simulations to develop an extensive library of performance studies and synthesis
techniques to identify generic performance trends and “rules of thumb” regarding the appropriate
deployment of micro-generation technologies.
Subtask C - Technically Robust Mechanisms for Diffusion
This subtask contains work related to the interaction between technical performance, economic
instruments, and commercialisation strategies and provisions this information to the relevant
decision makers. Given the importance of micro-generation in meeting many countries’ climate-
change targets, the subtask assesses the ability of micro-generation to enter the market and deliver
on national and international energy policy objectives.
![Page 61: Synthesis Report on the Viability of Micro-Generation ... · Synthesis Report on the ... This report is the result of an international project performed within Annex 54 of the](https://reader033.vdocuments.mx/reader033/viewer/2022051803/5b0101da7f8b9ab9598ba6f1/html5/thumbnails/61.jpg)
61
Research Partners of Annex 54
Belgium Catholic University of Leuven
Canada Natural Resources Canada
National Research Council
Carleton University
Denmark Dantherm Power A/S
Germany Research Center for Energy Economics (FfE)
Technische Universität München (TUM)
University of Applied Science of Cologne
Italy Università degli Studi del Sannio
Seconda Università di Napoli (SUN)
National Agency for New Technologies,
Energy and Sustainable Economic Development (ENEA)
Università Politecnica delle Marche
Japan Tokyo University of Agriculture and Technology
Osaka University
Nagoya University
Tokyo Gas
Osaka Gas
Toho Gas
Saibu Gas
Mitsubishi Heavy Industry Ltd
Yanmar Energy Systems Ltd
Korea Korean Institute for Energy Research (KIER)
Netherlands Technische Universiteit Eindhoven (TU/E)
United Kingdom University of Strathclyde, Scotland
Imperial College London, England
University of Bath, England
United States National Institute for Standards and Technology (NIST)