ECSS-Q-ST-70-13C 15 November 2008
Space product assurance Measurement of the peel and pull-off strength of coatings and finishes using pressure-sensitive tapes
ECSS Secretariat ESA-ESTEC
Requirements & Standards Division Noordwijk, The Netherlands
ECSS‐Q‐ST‐70‐13C 15 November 2008
Foreword
This Standard is one of the series of ECSS Standards intended to be applied together for the management, engineering and product assurance in space projects and applications. ECSS is a cooperative effort of the European Space Agency, national space agencies and European industry associations for the purpose of developing and maintaining common standards. Requirements in this Standard are defined in terms of what shall be accomplished, rather than in terms of how to organize and perform the necessary work. This allows existing organizational structures and methods to be applied where they are effective, and for the structures and methods to evolve as necessary without rewriting the standards.
This Standard has been prepared by the ECSS Executive Secretariat endorsed by the document and discipline focal point and approved by the ECSS Technical Authority.
Disclaimer
ECSS does not provide any warranty whatsoever, whether expressed, implied, or statutory, including, but not limited to, any warranty of merchantability or fitness for a particular purpose or any warranty that the contents of the item are error‐free. In no respect shall ECSS incur any liability for any damages, including, but not limited to, direct, indirect, special, or consequential damages arising out of, resulting from, or in any way connected to the use of this Standard, whether or not based upon warranty, business agreement, tort, or otherwise; whether or not injury was sustained by persons or property or otherwise; and whether or not loss was sustained from, or arose out of, the results of, the item, or any services that may be provided by ECSS.
Published by: ESA Requirements and Standards Division ESTEC, P.O. Box 299, 2200 AG Noordwijk The Netherlands Copyright: 2008 © by the European Space Agency for the members of ECSS
2
ECSS‐Q‐ST‐70‐13C 15 November 2008
Change log
ECSS‐Q‐70‐13A
4 October 1999
First issue
ECSS‐Q‐ST‐70‐13B Never issued
ECSS‐Q‐ST‐70‐13C
15 November 2008
Second issue
The following is a summary of changes between ECSS‐Q‐70‐13A and the present issue:
• Redrafting ECSS‐Q‐70‐13A according to ECSS drafting rules and new template.
• Reorganization of the content to separate descriptive text and requirements and creation of DRD.
3
ECSS‐Q‐ST‐70‐13C 15 November 2008
Table of contents
Change log.................................................................................................................3
1 Scope.......................................................................................................................6
2 Normative references.............................................................................................7
3 Terms, definitions and abbreviated terms............................................................8 3.1 Terms from other standards .......................................................................................8 3.2 Terms specific to the present standard ......................................................................8 3.3 Abbreviated terms ......................................................................................................8
4 Principles ................................................................................................................9
5 Requirements........................................................................................................11 5.1 Preparatory conditions .............................................................................................11
5.1.1 Hazards, health and safety precautions .....................................................11 5.1.2 Preparation of samples...............................................................................11 5.1.3 Facilities......................................................................................................13 5.1.4 Equipment ..................................................................................................13
5.2 Test procedure .........................................................................................................15 5.2.1 Preparation .................................................................................................15 5.2.2 Peel and pull-off test...................................................................................15 5.2.3 Handling and packaging of tested samples................................................16
5.3 Acceptance criteria...................................................................................................16 5.4 Quality assurance.....................................................................................................17
5.4.1 Data ............................................................................................................17 5.4.2 Nonconformance ........................................................................................17 5.4.3 Calibration ..................................................................................................17 5.4.4 Traceability .................................................................................................17
Annex A (normative) Test result sheet - DRD .......................................................18
Annex B (informative) Peel and pull-off test procedure.......................................21
Annex C (informative) Fracture lines.....................................................................23
4
ECSS‐Q‐ST‐70‐13C 15 November 2008
Bibliography.............................................................................................................24 Figures Figure 4-1 Test procedure flow diagram ................................................................................10 Figure 5-1: Side view of the test fixtures ................................................................................14 Figure A-1 : Example of test result sheet ...............................................................................20 Figure C-1 : Schematic cross-section of a coated substrate showing various fracture
lines dependent on the weakest layer .................................................................23
5
ECSS‐Q‐ST‐70‐13C 15 November 2008
1 Scope
This Standard details a test in which pressure‐sensitive tapes are used to assess the suitability of, for example, coatings, paints, films and other thin materials, proposed for use on spacecraft and associated equipment.
Surface coatings, such as thermal control paints and corrosion protection coatings, are affected, both on the ground and after launch, by exposure to the environment.
It is therefore important that the adhesion of the coating to the relevant substrate remains at an acceptable level after exposure to the relevant environmental condition.
The following materials and assemblies are covered by this test method:
• organic coating, e.g. varnishes, paints and plastic films;
• metallic finishes on, for example, printed circuit boards, second‐surface mirrors, thermal radiators, plastic films;
• adhesive layers;
• composite thin films;
• small assemblies, e.g. solar cells having attached glass covers.
This standard may be tailored for the specific characteristics and constrains of a space project in conformance with ECSS‐S‐ST‐00.
6
ECSS‐Q‐ST‐70‐13C 15 November 2008
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this ECSS Standard. For dated references, subsequent amendments to, or revision of any of these publications do not apply, However, parties to agreements based on this ECSS Standard are encouraged to investigate the possibility of applying the more recent editions of the normative documents indicated below. For undated references, the latest edition of the publication referred to applies.
ECSS‐S‐ST‐00‐01 ECSS system – Glossary of terms
ECSS‐Q‐ST‐10‐09 Space product assurance – Nonconformance control system
ECSS‐Q‐ST‐20 Space product assurance – Quality assurance
ECSS‐Q‐ST‐40 Space product assurance – Safety
ECSS‐Q‐ST‐70‐02 Space product assurance – Thermal vacuum outgassing test for the screening of space materials
7
ECSS‐Q‐ST‐70‐13C 15 November 2008
3 Terms, definitions and abbreviated terms
3.1 Terms from other standards For the purpose of this Standard, the terms and definitions from ECSS‐S‐ST‐00‐01 apply, in particular for the following terms:
requirement
3.2 Terms specific to the present standard 3.2.1 batch quantity produced at one operation.
NOTE One batch can be subdivided into several lots.
3.3 Abbreviated terms For the purpose of this Standard, the abbreviated terms from ECSS‐S‐ST‐00‐01 and the following apply:
Abbreviation Meaning RH relative humidity
8
ECSS‐Q‐ST‐70‐13C 15 November 2008
4 Principles
This Standard details a test in which pressure‐sensitive tapes are used to assess the suitability of, for example, coatings, paints, films and other thin materials, proposed for use on spacecraft and associated equipment.
This test has nine test steps as outlined in Figure 4‐1.
9
ECSS‐Q‐ST‐70‐13C 15 November 2008
Figure 4‐1 Test procedure flow diagram
3. Prepare tape holder: Locate tape over rubber block and clamp in place, see Error! Reference source not found.a.3 - 5.
4. Mount sample and tape holders in test machine, see Error! Reference source not found.a.6 and 7.
5. Raise jig until sample touches surface of tape, see Error! Reference source not found.a.8.
Peel and pull-off test: See 5.2.2
2. Condition for nominal 24 hours at (22 ± 3) ºC, RH (55 ±10) %, see 5.2.1.2.
Preparation: See 5.2.1
6. Compress sample onto tape with load of nominal 5 kg for a nominal 60 seconds, see Error! Reference source not
7. Reverse compression by pulling apart tape and sample at a nominal 0,2 cm/min until separation occurs, see Error!
8. Additional test: If separation is between tape and sample surface without damage,
repeat steps 3 to 7 above using tape with higher peel strength, see Error! Reference source not found.a.11. - 13.
9. Acceptance criteria, see 5.3.
1. Mount sample in sample holder, see 5.2.1.1.
10
ECSS‐Q‐ST‐70‐13C 15 November 2008
5 Requirements
5.1 Preparatory conditions
5.1.1 Hazards, health and safety precautions a. The supplier shall identify, manage and process materials and parts with
hazardous characteristics according to ECSS–Q‐ST‐40.
b. The supplier shall keep the health and safety precautions according to the supplier’s national safety regulations.
5.1.2 Preparation of samples
5.1.2.1 Configuration a. The supplier shall prepare the material samples according to the process
specifications or manufacturer’s data.
b. The material samples shall be representative of batch variance.
c. If it is not practicable to test completed assemblies, the supplier shall submit samples made from the same materials and by the same processes as those used in the manufacture of the assemblies.
d. The sample for testing shall have clean flat surfaces which do not overlap the sample holder described in clause 5.1.4.
e. The width of the test sample surface face shall be at least equal to the width of the tape used in the test procedure.
f. The nominal tape width shall be 20 mm.
g. The supplier shall specify the number of samples to be taken from a qualification batch, test programme, or production batch at the start of the test in conformance with the DRD in Annex A..
h. The supplier shall test at least ten test samples.
i. If it is not practicable to obtain test samples from the finished article, the supplier shall furnish bonded test samples for the test.
NOTE These samples are not used for any other purpose than the designated test.
j. The supplier shall furnish a certificate of conformity for the purpose of traceability.
11
ECSS‐Q‐ST‐70‐13C 15 November 2008
NOTE This certificate of conformity is delivered by the manufacturer in order to provide evidence that the product is compliant with the manufacturer’s process.
k. The supplier shall mark all test samples with identification to maintain traceability but in such a way as not to degrade the quality of the sample during testing.
5.1.2.2 Cleaning a. The suppler shall perform the same cleaning and other treatments of the
sample as that applied to the finished article, which the sample is intended to represent, prior to integration into the spacecraft.
b. The supplier shall not carry out further cleaning or other treatments.
5.1.2.3 Handling and storage a. The supplier shall handle the samples only with clean nylon or lint‐free
gloves.
b. The supplier shall store the samples in a controlled area, with an ambient temperature of (22 ± 3) °C and relative humidity of (55 ± 10) %.
c. The supplier shall shield coated surfaces from contact by using polyethylene or polypropylene bags or sheets.
d. The supplier shall avoid physical damage by packing the polyethylene or polypropylene‐wrapped workpieces in clean, dust‐ and lint‐free material.
e. The supplier shall label limited‐life materials with their shelf lives and dates of manufacture, or date of delivery if date of manufacture is not known.
5.1.2.4 Identification
5.1.2.4.1 Materials
a. The supplier shall identify materials submitted for testing in conformance to annex A of ECSS‐Q‐ST‐70‐02.
5.1.2.4.2 Assemblies
a. The supplier shall identify assemblies submitted for testing, as a minimum, by:
1. trade name and batch number;
2. name of manufacturer or supplier through whom the purchase was made;
3. configuration control status of the assembly.
12
ECSS‐Q‐ST‐70‐13C 15 November 2008
5.1.3 Facilities
5.1.3.1 Cleanliness a. The work area shall be clean and free of dust.
b. The supplier shall filter the air used for ventilation to prevent contamination of the sample.
5.1.3.2 Sample conditioning a. The supplier shall environmentally condition the sample for a nominal 24
hour period at (22 ± 3) °C with a relative humidity of (55 ± 10) %. NOTE 1 The humidity requirement can be achieved
either in a conditioning room, or by dessicators filled with silica gel or a saturated salt solution.
NOTE 2 A saturated salt solution of calcium nitrate gives approximately 51 % relative humidity at the testing temperature.
5.1.4 Equipment
5.1.4.1 Special equipment a. The supplier shall use the equipment as detailed in clauses 5.1.4.2 and
5.1.4.3.
5.1.4.2 Testing machine a. The supplier shall employ a power‐driven machine capable of
maintaining a specified constant rate of loading and able to be used for both tensile and compressive testing.
b. The machine shall have a fixed or essentially stationary member supporting a load cell and the tape holder.
c. A movable member shall carry the sample holder.
d. The applied compressive and tensile loads, as measured and recorded, shall be accurate within 1 percent of the load.
e. The rate of travel of the sample holder shall be at a nominal rate of 0,2 cm/min.
5.1.4.3 Fixtures a. The tape holder should be of a design similar to that depicted in Figure 5‐1.
b. The part shall be screwed into the fixed member of the testing machine or be located firmly on it.
c. The supplier shall clamp a length of pressure‐sensitive tape from one tape holder over the rubber block to the other tape holder.
d. The surface of the pressure‐sensitive tape in contact with the flat surface of the rubber block shall be 4 cm2 ± 5 %.
13
ECSS‐Q‐ST‐70‐13C 15 November 2008
Screw thread
Fixed member of test machine(with load cell)
Clamping washers
Pressure-sensitive tape
Rubber block
Sample
2 cmScaleSample holder
Tape holder
Test machine adapter
Movable member of test machine
Sample support (“top hat”)
Figure 5‐1: Side view of the test fixtures
14
ECSS‐Q‐ST‐70‐13C 15 November 2008
5.1.4.4 Sample holder a. The sample holder shall be firmly located beneath the tape holder on the
movable member of the testing machine. NOTE 1 A suitable design is seen in Figure 5‐1. NOTE 2 This preferred system utilizes “top hat”
supports onto which individual samples can be mechanically clamped or bonded in such a way that there is no relative movement between the support and the test sample at any time during the test cycle.
b. In case a “top hat” sample support is used, it shall slide into a horizontal fixture slot in such a way that its top surface is parallel to and directly beneath the rubber face of the tape holder.
5.1.4.5 Peel adhesion tape a. The supplier shall employ a range of pressure‐sensitive tapes for the tests
with peel adhesion strengths of 220, 330, 440 and 670 g/cm, all with a tolerance of ± 10 %.
5.2 Test procedure
5.2.1 Preparation
5.2.1.1 Mounting a. The supplier shall locate the test sample on the sample holder in
conformance with the requirements stated in clause 5.1.4.3.
b. If an adhesive bond is used between the sample and the sample support, this shall in no way interfere with the area under test.
c. The supplier shall ensure that there is no physical or chemical interaction between any adhesive employed during sample preparation and the sample materials.
5.2.1.2 Conditioning a. The supplier shall condition the loaded sample support for a nominal
24 hours in conformance with the requirements stated in clause 5.1.3.2 before the test starts.
5.2.2 Peel and pull-off test a. The supplier should run the peel and pull‐off test as described in Annex B.
b. If the supplier uses a different procedure, the supplier shall submit it for customer approval.
15
ECSS‐Q‐ST‐70‐13C 15 November 2008
5.2.3 Handling and packaging of tested samples a. The supplier shall apply the conditions specified in clause 5.1.2.3 unless
other post test disposal instructions are given.
5.3 Acceptance criteria a. The supplier shall classify samples which have been tested and are not
seen to be disturbed in any way by the processing described in clause 5.2.2 as having passed this test.
b. The supplier shall examine samples in detail, which have been disturbed during the test sequence.
c. The supplier shall carry out a visual examination for sample defects at ×7 magnification.
d. In case defects are detected at ×7 magnification, the supplier should use higher magnifications during further analysis for locating microscopic defects on any fracture surfaces.
e. The supplier shall report defects and the appearance of the fracture. NOTE 1 Defects for instance can be air bubbles or
material inclusions. NOTE 2 Appearance of the fracture for instance can be
rough, ductile, smooth or brittle.
f. The supplier shall state the particular material or interface along which the fracture path has propagated through the test sample.
NOTE This can be wholly or partly an adhesion fracture, a cohesive separation or an adherent fracture as schematically drawn in Figure C‐1.
g. The supplier shall take a photographic record of the tested samples at appropriate level of magnification.
NOTE Typical topographical features are recorded at ×2, ×20, ×50, ×100, ×250, ×500 or ×1000 magnifications.
h. The supplier shall agree with the customer on the granularity level of failure analysis to be performed on failed samples, prior to the test.
i. The supplier shall perform the failure analysis as agreed with the customer.
NOTE This failure analysis can include metallographic studies, chemical analysis or scanning electronic microscopy.
16
ECSS‐Q‐ST‐70‐13C 15 November 2008
5.4 Quality assurance
5.4.1 Data a. The supplier shall retain the quality records for at least ten years or in
conformance with project business agreement requirements, and in conformance with the Test result sheet ‐ DRD in Annex A.
NOTE Example of such quality records are logbooks.
5.4.2 Nonconformance a. The supplier shall disposition any nonconformance which is observed in
respect of the test process in conformance with the quality assurance requirements specified in ECSS‐Q‐ST‐10‐09.
5.4.3 Calibration a. The supplier shall use only measuring equipment calibrated to traceable
reference standard.
b. The supplier shall record any suspected or actual equipment failure as a project nonconformance report according to ECSS‐Q‐ST‐20.
NOTE This is to ensure that previous results can be examined to ascertain whether or not re‐inspection and retesting is required.
c. The supplier shall notify the customer of the nonconformance details.
5.4.4 Traceability a. The supplier shall maintain traceability throughout the process from
incoming inspection to final test, including details of test equipment and personnel employed in performing the task.
17
ECSS‐Q‐ST‐70‐13C 15 November 2008
Annex A (normative) Test result sheet - DRD
A.1 DRD identification
A.1.1 Requirement identification and source document This DRD is called from ECSS‐Q‐ST‐70‐13, requirement 5.4.1a.
A.1.2 Purpose and objective The purpose of the test result sheet is to summarize the test results.
A.2 Expected response
A.2.1 Scope and content a. The test result sheet shall contain the trade names of the materials under
test.
b. The test result sheet shall contain the batch numbers of the materials under test.
c. The test result sheet shall contain name of manufacturer or supplier through whom the purchase was made.
d. The test result sheet shall contain summary of the preparation and conditioning schedule.
NOTE This can be for instance the mixing proportions, coating thickness, cure time and temperature, post‐cure or cleaning procedure.
e. The test result sheet shall contain details of the testing room environment conditions and test equipment.
f. The test result sheet shall contain details of the test parameters outlined in Annex B.
NOTE This also includes any variation in testing environment conditions.
18
ECSS‐Q‐ST‐70‐13C 15 November 2008
g. The test result sheet shall contain details of equipment used for visual, mechanical, chemical and physical property measurement or inspection, as outlined in Annex B and test specifications where they exist.
h. The test result sheet shall contain the number of sample tests.
i. The test result sheet shall contain the results of the values obtained for peel or pull‐off strength.
j. The test result sheet shall contain the peel strength indicated by the manufacturer of the pressure‐sensitive tape used.
k. The test result sheet shall contain the results of any failure analysis carried out according to clause 5.3.
l. The test result sheet shall contain the mode of fracture and any photographic records.
NOTE An indication of the various fracture line is given in Figure C‐1.
m. In case of failures, the test result sheet shall contain the following details of failure mode:
1. deficient design;
2. poor workmanship;
3. wrong fabrication or application procedure;
4. wrong choice of materials;
5. others.
A.2.2 Special remarks The supplier may use the template given in Figure A‐1.
19
ECSS‐Q‐ST‐70‐13C 15 November 2008
Materials Section, Product Assurance Division, ESTEC Sample details 1. Description and history of sample: 2. Trade name: 2. Batch number: 4. Coating or finish material manufacturer: 5. Supplier through whom material is purchased: 6. Coating or finish prepared by: 7. Summary of preparation schedule: 8. Number of samples submitted: 9. Criteria for test, e.g. lowest acceptable peel or pull-off strength:
10. Project and cost code number: Date: Originator: Telephone:
Test results 11. Test equipment: 12. Test temperature: °C 13. Relative humidity: % 14. Speed of testing: cm/min 15. Sample number
16. Peel strength of tape employed *
17. Peel or pull-off strength of sample **
18. Mode of fracture, see Figure 3
19. Further examinations
Conclusions Date: Test engineer: Approval: * as indicated by manufacturer, the peel strength of tape when sample separation commenced is underlined. ** from chart record
Figure A‐1: Example of test result sheet
20
ECSS‐Q‐ST‐70‐13C 15 November 2008
Annex B (informative) Peel and pull-off test procedure
a. The supplier should perform the peel and pull‐off test according to the following procedure:
1. conduct the test as soon as possible after the loaded sample support has been removed from the conditioning atmosphere;
2. conduct the test under the same environment conditions;
3. prepare the tape holder by hand;
4. fix a length of the lowest peel‐strength tape in such a way that it follows the contour of the rubber block without creases, folds, visible surface flaws or slack spots;
5. secure the two free ends of the tape and stretches the tape so as to leave no slack;
6. locate the tape holder and sample support holder on the fixed member and the movable member of the machine respectively;
7. position the sample under test, being bonded onto the sample support, in the support holder in such a way as to be directly beneath the rubber block of the tape holder;
8. then raise the lower adjustable member of the machine so that the surface of the test sample comes into contact with the pressure‐sensitive tape;
9. apply a compressive load of a nominal 5 kg for a nominal 60 s, so as to ensure that the pressure‐sensitive tape is in positive contact with the sample surface;
10. move away the movable member of the machine from the test sample at a constant rate of a nominal 0,2 cm/min until such time as there is complete detachment between the tape and the sample;
11. visually examine the parted surfaces at a magnification of between ×3 and ×7;
12. With this examination, determine whether separation has occurred cleanly between the tape and the sample surface or whether the surface finish has delaminated from the substrate of the sample;
13. In the case where separation has occurred cleanly between the tape and the sample surface, remove the tape fixture from the machine and replace the used tape by a new length of tape having a greater peel strength;
21
ECSS‐Q‐ST‐70‐13C 15 November 2008
14. recommence the procedure from step 3;
15. Continue the procedure until either delaminating of the surface finish occurs, or the tape having the maximum peel strength given at clause 5.1.4.5 has been employed.
22
ECSS‐Q‐ST‐70‐13C 15 November 2008
Annex C (informative) Fracture lines
Figure C‐1 represents an schematic cross‐section of a coated substrate showing various fracture lines dependent on the weakest layer.
Rubber block
Sample coating X X
Pressure-sensitive tape
Sample substrate
X XBonding agent
Sample support (“Top-hat”)
a) Tape separationNo sample fracture
b) Coating adhesion fracture Fracture such that the plane of separation appears to be at the coating/substrate interface.
c) Cohesive fracture Fracture such that the plane of separation appears to be within the coating.
d) Adherent of substrate fracture Fracture such that the separation appears to be within the adherent or substrate.
X X
X X
Legend: X X =mean of fracture
Figure C‐1: Schematic cross‐section of a coated substrate showing various fracture lines dependent on the weakest layer
23
ECSS‐Q‐ST‐70‐13C 15 November 2008
Bibliography
ECSS‐S‐ST‐00 ECSS system – Description, implementation and general requirements
24