Sound power measurements
CHRISTER HEED
SD2165
Stockholm October 2008
-
8/10/2019 Sound Power Measurements
2/16
Marcus Wallenberg Laboratorietfr Ljud- och Vibrationsforskning
Sound power measurements
Christer Heed
Approved
Date:
Signature:
SD2165 Acoustical measurements
-
8/10/2019 Sound Power Measurements
3/16
1
ABSTRACT
Three different measurement methods to determine sound power level of a sound source
are compared. Two methods are sound pressure methods. The first one is a comparison
method, using a reference sound source and the second one is a direct method without
using a reference sound source. Third, the sound power level is measured with a sound
intensity method, using scanning. The comparison method yields octave band with thecentre frequency range 125 Hz - 8 kHz and A-weighted sound power level. The direct
method yields only A-weighted sound power level. The intensity method yields octave
band with the centre frequency range 125 Hz - 4 kHz and A-weighted sound power level.
Standards for all methods are used. The comparison method and the intensity method
attain engineering accuracy (grade 2). A few minor derogations are made from them. The
standard deviation should still be about 1.5 dB. The discrepancy of the results of these
two methods is less than 1 dB. The discrepancy is most significant at the 125 Hz and the
500 Hz octave bands. The direct method attain survey accuracy (grade 3) and thus the
standard deviation of the direct method is 4 dB and its determined sound power level is 1
dB higher than for the intensity method and 2 dB higher than for the comparison method.
SAMMANFATTNING (the abstract in Swedish)
Tre olika mtmetoder fr att bestmma ljudeffektnivn frn en ljudklla jmfrs. De tv
frsta r ljudtrycksmtmetoder, med jmfrandet av en referensljudklla respektive utan.
Medan den tredje r en intensitetsmetod med scanning. Intensitetsmetoden ger
ljudeffektnivn i oktavband med centerfrekvenser 125 Hz 4 kHz och den A-vgda. Fr
jmfrandemetoden fs ljudeffektnivn i oktavband med centerfrekvenser 125 Hz 8
kHz och den A-vgda. Fr den direkta ljudtrycksmetoden fs bara A-vgd ljudeffektniv.
Standarder fr alla metoder anvnds. Mest noggrann r jmfrandemetoden och
intensitetsmetoden. Ngra mindre avsteg frn dessa bdas standarder grs, men i princip
r standardavvikelsen 1,5 dB. Skillnaden i resultatet mellan de bda noggrannare
metoderna r mindre n 1 dB. Skillnaden r strst i 500 Hz oktavbandet och i 125 Hz
oktavbandet. Den direkta metoden har standardavvikelsen 4 dB och dess bestmda
ljudeffektniv r 1 dB hgre n den fr intensitetsmetoden och 2 dB hgre n den fr
jmfrandemetoden.
-
8/10/2019 Sound Power Measurements
4/16
2
TABLE OF CONTENTS
1 INTRODUCTION.......................................................................................................3
1-1 Task .....................................................................................................................3
1-2 Test object and its physical description ...............................................................3
2 STANDARDS .............................................................................................................4
2-1 ISO 3747:2000 - Determination of sound power levels of noise sources usingsound pressure -- Comparison method in situ .................................................................4
2-2 ISO 3746:1995 - Determination of sound power levels of noise sources using
sound pressure -- Survey method using an enveloping measurement surface over a
reflecting plane ................................................................................................................4
2-3 ISO 9614-2:1994 - Determination of sound power levels of noise sources using
sound intensity -- Part 2: Measurement by scanning.......................................................4
3 MEASUREMENTS ....................................................................................................4
3-1 Measurement environment ..................................................................................4
3-2 Instrumentation....................................................................................................4
3-3 Data acquisition and settings ...............................................................................5
3-4 Measurement procedure, using ISO 3747:2000 ..................................................53-4-1 Calibration of the measurement system ......................................................5
3-4-2 Measurement of the indicator of accuracy ..................................................5
3-4-3 Measurement of the sound pressure levels ..................................................6
3-4-4 Measuring the background- sound pressure level and noise correction......6
3-4-5 Measurement result .....................................................................................6
3-5 Measurement procedure, using ISO 3746:1995 ..................................................6
3-5-1 Reference box, measurement surface and microphone positions ................6
3-5-2 Estimation of environment correction .........................................................7
3-5-3 Measurements and result .............................................................................7
3-6 Measurement procedure, using the intensity method, ISO 9614:1994................8
3-6-1 The intensity method by scanning ...............................................................8
3-6-2 Calibration ...................................................................................................8
3-6-3 Scanning ......................................................................................................8
3-6-4 Requirements...............................................................................................9
3-6-5 Calculations, measurement results and accuracy ........................................9
3-6-6 Derogation ...................................................................................................9
3-6-7 Results .........................................................................................................9
4 DISCUSSION............................................................................................................10
4-1 Comparison of the results ..................................................................................10
4-2 Comparison of the results in octave bands ........................................................10
4-3 Measurement improvements .............................................................................114-4 The importance of calibration............................................................................11
4-5 Advantages ........................................................................................................11
5 REFERENCES..........................................................................................................11
6 APPENDIX ...............................................................................................................12
6-1 Measurement, results and calculations ..............................................................12
6-1-1 The comparison method, ISO 3747...........................................................12
6-1-2 The direct method, ISO 3746 ....................................................................13
6-1-3 The intensity method, ISO 9614................................................................14
6-2 Important parameters of measurement accuracy [4] .........................................14
-
8/10/2019 Sound Power Measurements
5/16
3
1 INTRODUCTION
1-1 Task
The task is to practice and compare different sound power measurement methods. Three
different methods are being used to determine the sound power level of a sound source.
First, the sound power level is measured with a sound pressure method by using a
reference sound source. Second, sound power level is measured with a sound pressuremethod without the reference sound source. Third, the sound power level is measured
with a sound intensity and scanning method. These methods are further described in
sections 2 and 3.
1-2 Test object and its physical description
The test object that is used as a sound source for the measurements is a grinding machine,
to the left in figure 1. It is mounted on a wooden board.
Figure 1:To the left, the test object is a grinding machine and to the right the reference
sound source from Brel & Kjaer that is used in the first method, ISO 3747:2000.
The technical data of the test object are as follows:
Dimensions (reference box):o Length: 0.36 mo Width: 0.25 mo Height: 0.28 m
Weight (estimated): 5 kg
-
8/10/2019 Sound Power Measurements
6/16
4
2 STANDARDS
To determine the Sound Power Level, the following three standards are used. The
methods and requirements are specified in sections 3-4 to 3-6 respectively.
2-1 ISO 3747:2000 - Determination of sound power levels of noise sources
using sound pressure -- Comparison method in situThis standard describes how to determine the sound power level with a comparison sound
pressure method by using a reference sound source, [1, 2].
2-2 ISO 3746:1995 - Determination of sound power levels of noise sources
using sound pressure -- Survey method using an enveloping measurement surface
over a reflecting plane
This standard describes how to determine the sound power level with a direct sound
pressure method, i.e. without using a reference sound source [1, 3].
2-3 ISO 9614-2:1994 - Determination of sound power levels of noise sourcesusing sound intensity -- Part 2: Measurement by scanning
This standard describes how to determine the sound power level with an intensity method
by scanning acoustic intensity of the object, [1, 4].
3 MEASUREMENTS
3-1 Measurement environment
The environmental data and date are as follows:
Measure location: Room MWL 75, KTH in Stockholm Swedeno Dimensions (LWH): 6.7 m 6 m 4.5 m
Date: 25 September 2008 Air temperature: 22 C Relative humidity: 44 %
3-2 Instrumentation
The following equipment where used for the measurements:
Frequency analyzer: HP 3568Ao Serial No.: 3442A00389
Sound level calibrator: Brel & Kjaer type 4230o Level.: 94.4 dB at 1000 Hz
Microphone: MK225, Pre-polarized condenser microphoneo Serial No.: 970486
Reference sound source (RSS): Brel & Kjaer Type 4204o Serial No.: 955287
Sound intensity calibrator: GRAS 51ABo Serial No.: 29559
Intensity probe: Brel & Kjaer 2681o Serial No.: 1894856
o Microphone capsules: Type 4181, Pre-polarized condenser microphone Serial No.: 1963773 (Part 1)
Sensitivity: 10.05 mV/EU (Calibrated)
-
8/10/2019 Sound Power Measurements
7/16
5
Serial No.: 1863773 (Part 2)
Sensitivity: 10.01 mV/EU (Calibrated)o Spacer: 12 mm UC5269
Data processing software: Microsoft Excel
The microphone is mounted on an ordinary microphone stand and is connected to the
frequency analyzer. When the Intensity probe is used it is connected to the frequencyanalyser input 1 and 2. The data is transferred to Excel by hand and the calculations are
available in the appendix. Further pictures of the instrumentation are available from the
author on request.
3-3 Data acquisition and settings
The frequency analyzer, see section 2-2, is used to integrate and average the sound
pressure for the two sound pressure methods. For the intensity method the frequency
analyser is also used to integrate and average the sound intensity over a well defined area
and calculates the sound power level in octave bands. It is also used to calculate the
accuracy of the measurements as described in 3-6-5. For the analyzer settings andmanagement, see the reference [1] side 110 and forward.
3-4 Measurement procedure, using ISO 3747:2000
The test object is located on the floor approximately in the middle of the room. The
reference sound source (RSS) is placed next to it, see figure 1. This comparison method
gives octave band and A-weighted sound power levels. All measurements are made in
octave bands with the centre frequency range 125 Hz 8 kHz from which the A-weighted
is calculated.
Four microphone positions in different directions and heights are chosen in such a way
they can reflect the influence of the environment, that is, they are positioned rather close
to a wall. The microphone distance could be seen in table 1 in appendix 6-1-1 where the
measurement results are presented.
3-4-1 Calibration of the measurement system
The first step is to calibrate the microphone. For this the sound level calibrator and the
HP-analyzer are used. The sound pressure level of the calibrator (94.4 dB) is entered to
the HP-analyzer. The microphone sensitivity is 53.8 mV/Pa, which is close to the
sensitivity supplied by the manufacturer. This is done in the measurement environment
before the actual measurements take place.
3-4-2 Measurement of the indicator of accuracy
The sound pressure level( )'pi RSSL is recorded in octave bands into the analyser while the
RSS is running. The indicatorf
L is calculated in excel according to [1]. The value of
fL decides the achievable accuracy of the measurements. To attain engineering
accuracy (grade 2),f
L have to be larger than 7 dB. The upper value of the standard
deviation of reproducibility for the A-weighted sound power level is then 1.5 dB, [2]. The
microphone position is changed (farther away) till the indicator meets the requirement of
grade 2 accuracy. Due to the low humidity, fL is to low for the 8 kHz octave band.
-
8/10/2019 Sound Power Measurements
8/16
-
8/10/2019 Sound Power Measurements
9/16
7
Figure 2: The reference box (grey) is located inside the measurement surface. Thegrinding machine can fit exactly in the reference box. The red squares mark the
microphone positions, 1 m from the reference box in the middle of each side. The fourth
position is at the front side opposite to the second position, but it would be inconvenient
to mark it in the figure. All units are in meters and the figure is not to scale.
3-5-2 Estimation of environment correction
An approximate method is used to determine the environment correction. The approximate value of
the mean sound absorption coefficient of the room is 0.25 as suggested in the standard [3]. Theenvironment correction is then calculated to K2A= 3.8, appendix 6-1-2.
3-5-3 Measurements and result
The set-up of the instruments is the same as for the previous method. The background noise ismeasured and then the sound pressure levels are measured at each of the five microphone positions.
Now the average A-weighted sound pressure level over the measurement surface could be
calculated. The background noise correction K1A is also calculated, but no correction is needed asthe background noise is more than 10 dB lower than the measured sound pressure level. The
measurement results and calculations are presented in appendix 6-1-2.
The A-weighted sound power level is being calculated to 70.3 ( )WA
L dB A= .
2.36
1.28
2.250.36
0.28
0.25
1.00
1.00
1
5
0.64
3
0.64
1.00
2
0.64
-
8/10/2019 Sound Power Measurements
10/16
8
3-6 Measurement procedure, using the intensity method, ISO 9614:1994
3-6-1 The intensity method by scanning
The intensity measurement method used for this measurement is scanning. By integratingthe sound intensity over a well known surface that embraces the measurement object, the
sound power is computed. The test object is located on the same place on the floor as in
the previous methods. For easier scanning with the intensity probe, the test object is inthis case embraced by four stands with strings attached parallel to the floor, which defines
the measurement surface as a parallelepiped box with the dimensions (LWH) 0.71 m 0.65 m 0.52 m. The surface is then S = 1.88 m2.
The frequency analyzer integrates the intensity over the area of the parallelepiped and the
sound power level is calculated and presented in octave bands and A-weighted. To be
able to compare the different measurement methods a 12 mm spacer is used, with whichthe effective frequency range is 100 Hz 5 kHz, [1]. The measured frequency range in
octave band will be 125 Hz 4 kHz.
3-6-2 Calibration
The first step is to calibrate the two microphone capsules in the intensity probe
separately. Then the intensity calibrator from G.R.A.S. is used to get the pressure residualintensity index pI measured in dB, this parameter is used to determine the degree of
accuracy, se section 3-6-6. This is done in the measurement environment before the finalmeasurements.
3-6-3 Scanning
One side of the surface is scanned at once, and is then paused in the analyzer. In thissetup it is not possible to use the remote control of the probe. Scanning is done by the two
orthogonal patterns in figure 3, i.e. first one segment is measured by first scanned withthe left pattern, and then without pausing the analyzer, the segment is scanned with the
right pattern. That is, the two measurements are averaged into a single spectrum. Then theanalyzer is paused and the measurement continues for the rest of the segments. The total
integrating time is set to 300 s and the recording is interrupted manually on the analyzerwhen the scanning is finished.
Figure 3:The two different scanning pattern that is used. The patterns is figurative and
not necessarily to scale.
-
8/10/2019 Sound Power Measurements
11/16
9
3-6-4 Requirements
The standard 9614, [4], requires that the integration time should be at least 20 s persurface segment and that the speed of scanning should be between 0.1 and 0.5 m/s. These
requirements are some of the requirements that should be fulfilled for the terms in 3-6-5.
In this case 30 s of integration time per segment is used and the average speed ofscanning is about 0.2 m/s.
3-6-5 Calculations, measurement results and accuracy
The sound intensity level as well as the sound pressure level for the measurement is
calculated by the analyzer in octave bands, A-weighted and linear. The measurementresults are given in table 3 in the appendix 6-1-3.
There are three different degrees of accuracy for sound power level measurements with
the intensity method. For this measurement, engineering accuracy (grade 2), is chosen. Ifthe standard is followed the standard deviation for the result is between 1.5 and 3 dB in
the octave bands (given in table 2 in appendix 6-1-3) and 1.5 dB for the A-weighted sincethe total A-weighted sound power in the bands outside the range 400 Hz to 5 kHz doesnt
exceed the total, according to [4], appendix 6-1-3. The true value of the A-weighted
sound power level is expected with a certainty of 95 % to be in the range of 3 dB [4].For grade 2 accuracy, the bias error factor, K, should be selected to 10 dB.
The most important parameters used to decide if the desired degree of accuracy isacquired in this case are: Pressure Residual Intensity Index - pIand Surface Pressure-
Intensity index - FpI. These are further explained in the appendix 6-2.
The results of the pressure residual intensity index - pI, together with the calculations of
the dynamic capacity index -LDare presented in table 3 in the appendix 6-1-3. The soundpower level is then calculated in Excel, appendix 6-1-3.
3-6-6 Derogation
Two important derogations from the standard is that only criterion 1 and not criterion 2
and 3 are used, i.e. the limit on negative partial power and the partial power repeatabilityis not checked, which is required according to attain engineering accuracy [4]. These
criterions are explained in the appendix 6-2-1. This could affect the accuracy of the
measurement results. The reason for the chosen method is because the data has to betransferred to the computer by hand and much time is saved this way.
3-6-7 Results
The Sound power level is 69.1 ( )WA
L dB A= and the sound power level in octave band is
presented in figure 5 in section 4-2.
-
8/10/2019 Sound Power Measurements
12/16
10
4 DISCUSSION
4-1 Comparison of the results
The discrepancy of the sound power level determination of the comparison method and
the intensity method is less than 1 dB and the deviation for each of them is 1.5 dB.Comparison of the results of all three methods is presented in figure 4.
Possible reasons of the discrepancy for the direct method are that it only attains survey
accuracy, and the standard deviation is thus 4 dB. The environment correction is
calculated to K2A= 3.8 dB (appendix 6-1-2), but according to the standard, it is calculatedfrom an approximate value of the mean sound absorption coefficient, = 0.25, that is
meant for basically an empty room with some furniture. In this case there were a lot ofabsorbing people present during the measurements. If is bigger, the correction will be
smaller, so this would make the sound power level even bigger.
In the comparison method the background noise was too high at the 125 Hz octave band
for microphone position 3 and could not be used. This should be a minor problembecause of the relatively small contribution to the A-weighted sound power level from
that frequency band. The sound absorption in the air is due to the low humidity a problem
for high frequencies. The accuracy indicatorf
L is too low at the 8 kHz octave band,
appendix 6-1-1.
Finally, for the intensity method there were two derogations from the standard whichcould have minor affect to the uncertainty of the measurement.
67
67,5
68
68,5
69
69,5
70
70,5
71
SPL (dB)
ISO 3747 ISO 3746 ISO 9614
A-weighted
Linear
Figure 4: Comparison of the A-weighted and linear sound power level for the threemethods: LW, ISO 3747 = 68.4 dB(A), LW, ISO 3746= 70.3 dB(A) and LW, ISO 9614= 69.1 dB(A).
4-2 Comparison of the results in octave bands
When analyzing the sound power level in octave band in figure 5, it is obvious that thereis a difference in the 125 Hz band between the two engineering accuracy methods. The
higher value for ISO 3747 is due to the high background noise, section 3-4-4. There isalso a rather big difference in the 500 Hz band. That could be due to problems with a
directive tone, environment changing or bad scanning technique, confer to section 3-6-6.
When A-weighting is made, the contribution from the 500 Hz band will be bigger then
from the 125 Hz band. The 8 kHz octave band, only measured in ISO 3747 is uncertaindue to the air absorption, mentioned in 4-1-1. One should also consider that the effectivefrequency range of the 12 mm spacer doesnt cover the 125 Hz- and 4 kHz octave bands
completely, confer to section 3-6-1.
-
8/10/2019 Sound Power Measurements
13/16
11
0
1020
30
40
50
60
70
SPL (dB)
125 250 500 1000 2000 4000 8000
Centre frequency (Hz)
ISO 3747
ISO 9614
Figure 5: Comparison of the sound power level from the two engineering accuracy
methods in octave band. Notice the difference in the 125 Hz and 500 Hz band. The 8 kHz
band is only measured with the comparison method, ISO 3747.
4-3 Measurement improvements
For the comparison method, the lower frequencies could be improved if the background
noise is reduced. If the humidity is raised the high frequencies gets better. It is alsopreferable with a more reverberant room. The direct method is difficult to improve since
the standard was fulfilled. The intensity method could be improved if all of the criterions
in the standard are followed and if the scanning technique could be improved. There isalso guidance in [4] to increase the grade of accuracy.
4-4 The importance of calibration
If the microphone is not calibrated before the measurements, one has to use the sensitivity
supplied by the manufacturer. For the sound pressure methods, the same microphone is
used, so they would be comparable without calibration. The value of the A-weightedsound power level however would not be correct. In this case though, the sensitivity wasrelatively close to the one supplied by the manufacturer. For the intensity method the
calibration is very important since it measure both pressure and intensity from two
opposite directions at the same time. Without the calibration it would not be comparableto the other methods due to that it uses the capsules instead of the microphone. Further
more, phase calibration has to be done for both capsules in order to get good accuracy.
4-5 Advantages
The major advantage with the intensity method is that it (in theory) does not depend on
the environment. There is no need to use expensive acoustic measurement rooms to get
high accuracy measurements [1]. Practically though, an acoustic room helps to getcontrol of the environment and thus the measurement accuracy could be improved.
This intensity measurement method is also a rather quick method due to the easyarrangement and rapid calculations of the sound power level.
5 REFERENCES
[1]: Leping Feng, Acoustical measurements, Lecture notes, TRITA-AVE 2007:07,
ISSN 1651-7660, 2nd
print (2008)
[2]: International Standard ISO 3747:2000, ICS 17.140.01[3]: International Standard ISO 3746:1995, ICS 17.140.01[4]: International Standard ISO 9614-2:1996(E), ICS 17.140.01
-
8/10/2019 Sound Power Measurements
14/16
12
6 APPENDIX
6-1 Measurement, results and calculations
All calculations are made in Microsoft Excel. The tables are showing the measuredvalues and the calculated values according to [1], side 110 119.
6-1-1 The comparison method, ISO 3747
Table 1a Microphone position 1, distance r = 2.8 m
Centrefrequency(Hz) ( )( )W RSS L dB ( )
'
( )pi RSSL dB ( )fL dB ( )
'
piL dB ( )' ( )pi BL dB ( )piL dB ( )f dB
125 78.2 73.0 14.74316 49.6 45.8 47.25766 3.8
250 80.7 69.8 9.043161 46.1 33 45.88191 13.1
500 81.4 72.1 10.64316 54.9 27.3 54.89245 27.6
1000 85.1 75.8 10.64316 52.9 25.9 52.89133 27.0
2000 85.3 73.3 7.943161 51.5 19.8 51.49706 31.74000 82.7 71.6 8.843161 41.5 14.8 41.49071 26.7
8000 79.3 65.7 6.343161 33.0 11.6 32.96842 21.4
Table 1b Microphone position 2, distance r = 3.48 m
Centrefrequency(Hz) ( )( )W RSS L dB ( )
'
( )pi RSSL dB ( )fL dB ( )
'
piL dB ( )' ( )pi BL dB ( )piL dB ( )f dB
125 78.2 69.5 13.13158 53.2 45.8 52.32769 7.4
250 80.7 67.3 8.431585 43.2 33 42.76409 10.2
500 81.4 69.9 10.33158 51.1 27.3 51.08186 23.8
1000 85.1 71.9 8.631585 54.0 25.9 53.99327 28.1
2000 85.3 72.3 8.831585 48.7 19.8 48.6944 28.94000 82.7 68.8 7.931585 40.0 14.8 39.98686 25.2
8000 79.3 63.6 6.131585 34.0 11.6 33.97494 22.4
Table 1c Microphone position 3, distance r = 4.39 m
Centrefrequency(Hz) ( )( )W RSS L dB ( )
'
( )pi RSSL dB ( )fL dB ( )'
piL dB ( )'
( )pi BL dB ( )piL dB ( )f dB125 78.2 64.9 10.54929 45.7 45.8 Not valid! -0.1
250 80.7 67.7 10.84929 47.2 33 47.03167 14.2
500 81.4 72.0 14.44929 53.8 27.3 53.79027 26.5
1000 85.1 79.0 17.74929 50.8 25.9 50.78592 24.9
2000 85.3 70.9 9.44929 49.3 19.8 49.29512 29.54000 82.7 68.2 9.34929 45.0 14.8 44.99585 30.2
8000 79.3 62.2 6.74929 32.6 11.6 32.56537 21.0
Table 1d Microphone position 4, distance r = 4.44 m
Centrefrequency(Hz) ( )( )W RSS L dB ( )
'
( )pi RSSL dB ( )fL dB ( )'
piL dB ( )'
( )pi BL dB ( )piL dB ( )f dB125 78.2 63.7 9.447659 14.74316 45.8 53.28725 8.2
250 80.7 67.5 10.74766 9.043161 33 45.88191 13.1
500 81.4 68.2 10.74766 10.64316 27.3 50.78056 23.5
1000 85.1 70.0 8.847659 10.64316 25.9 48.67715 22.8
2000 85.3 69.7 8.347659 7.943161 19.8 46.79133 27.0
4000 82.7 65.8 7.047659 8.843161 14.8 38.58186 23.8
8000 79.3 60.4 5.047659 6.343161 11.6 28.71645 17.2
-
8/10/2019 Sound Power Measurements
15/16
13
Tabell 1e Calculated sound power levels
Centrefrequency(Hz) ( )WL dB ( )nA dB ( )( )
0.110 W n
L A + ( ), ( )W AL dB A ( )0.110 WL 125 64.0 -16.1 60966.94662 47.9 2483673
250 58.3 -8.6 93412.17964 49.7 676711.4
500 63.5 -3.2 1083038.359 60.3 2262788
1000 63.9 0 2449068.312 63.9 24490682000 62.9 1.2 2570554.228 64.1 1949965
4000 56.2 1 526704.5887 57.2 418376.3
8000 48.6 -1.1 56519.33747 47.5 72811.01
Table 1a-e:The results from the measurements and calculations. The background sound
pressure level in table 1a-d, '( )pi B
L is red marked when' '
( )pi pi Bf L L = < 15 dB and is
then corrected topi
L according to [1].
( )( )( )0.1,The A-weighted sound power level is calculated as 10 log 10 68.4 ( )W nL AW AL dB A += =( )( )0.1The linear sound power level is calculated as 10log 10 70.1WLWL dB= =
6-1-2 The direct method, ISO 3746
A-weighted sound pressure levels
Microphone position, figure 2 ( )' , ( )pA iL dB A
1, Top 61.9
2 63.03 59.94 63.55 58.6
( )' , ( )pA averageL dB A 61.8
Table 2:The average of the measurements of the A-weighted sound pressure levels.
The environment correction is calculated to ( )( )2 10log 1 4 / 3.8 ,AK S A dB= + = where Sis the surface of the reference box, figure 2 and A is the total absorption of the room.
VA S= , where is the approximate value of the mean sound absorption coefficient of
the test room = 0.25 and SV is the total surface of the test room. The background noise
correction is1
0 ,A
K dB= so the A-weighted sound power level is:
( )', , 1 2 010log / 70.3 ( ),W A pA average A AL L K K S S dB A= + = where the reference surface
area is S0 = 1
-
8/10/2019 Sound Power Measurements
16/16
14
6-1-3 The intensity method, ISO 9614
Centrefrequency (Hz)
0( )
pIdB
( )I
L dB
( )P
L dB
( )WL dB
( )pl
F dB
( )dL dB
( )nA dB
( )WAL dB
125 15.5 55.5 59.3 58.2 3.8 5.5 -16.1 43.2
250 18.6 56.8 59.5 59.5 2.7 8.6 -8.6 50.9
500 26.0 64.9 66.9 67.6 2.0 16.0 -3.2
1000 22.7 61.5 63.1 64.2 1.6 12.7 0
2000 20.9 59.6 61.3 62.3 1.7 10.9 1.2
4000 25.0 52.8 54.2 55.5 1.4 15.0 1
( )( )WAL dB A 21.9 66.4 68.2 69.1 1.8 11.9( )WL dB 26.5 68.1 70.1 70.8 2.0 16.5
Table 3:The measurements results, both accuracy and sound power levels.
The pressure residual intensity index0pI
is calculated in the frequency analyzer. It should
be at minimum 16 dB when the frequency is equal or higher than 250 Hz in order to fulfil
the IEC requirements for class 1 instruments [1]. In this case it is fulfilled. The dynamiccapacity index is checked, see section 6-2. The total A-weighted sound power level from
the octave bands 125 Hz and 250 Hz is calculated to be able to check the accuracy of thetotal A-weighted sound power level, confer 3-6-5.
Finally0
10lognW I
SL L
S
= +
, where IL is the measured sound intensity level, S is the
measured surface and S0is the reference area (1 m2).
6-2 Important parameters of measurement accuracy [4]
The most important parameters used to decide if the desired degree of accuracy isacquired when using the standard ISO 9614 are:
Pressure Residual Intensity Index -0pI
is defined as the difference between the measured
sound pressure level and the measured sound intensity level when the probe is placed in a
sound field such that the intensity is zero. Thus this parameter is a measure of the qualityof the probe.
Surface Pressure-Intensity index - FpI is defined in [1]. FpI is an index of the quality of
the sound field. If FpI 0 the sound field is free and if FpI Lp the sound field is
diffuse, where Lpis the sound pressure level.
The dynamic capacity index - LDmust exceed FpIin all frequency bands and LDis given
by: LD =0pI
K, there K is the bias error factor, selected to 10 dB (criterion 1 in [4]).
The negative partial power indicator F+/-(criterion 2 and the definition in [4]), is an index
of the amount of absorption inside the integrated area. F+/-< 3dB is the criterion and inthis case it is not checked.
Partial power repeatability (criterion 3 in [4]) is the difference between two orthogonalscanned measurements. The difference must not exceed the standard deviation of 1.5 - 3
dB depending of the frequency band. The standard requires that this should be done onesegment at a time and then the total sound power level is calculated from the partial
sound powers. This is not checked in this exercise.